| Sl. No. | Item Description |
| 1 | BUILDING WORKS |
| 2 | Demolition of cement concrete ( unreinforced)in ground floors and pavings n. exe 15 cm thickness (below or above ground level ) including removal of debries out of defence land complete all as specified and directed |
| 3 | Material and labour forrendering 15mm thick in cement mortar (1:6),on brick/concrete surfaces of walls, finished even and smooth without using extra cement , complete all as specified and directed. |
| 4 | Material and labour for distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification. Two or more coatson new work,complete all as specified and directed. |
| 5 | Material and labour for applying two coats of Acrylic weather coatemulsion paint on walls/ceiling/facias/ramp surfaces etc in disruptive/camouflaging pattern having percentage of Six-colour as 29.04% of RGB Value (143,152,113), 22.48% of RGB Value (112,139,86), 14.98% of RGB value (123,137,126), 13.80% of RGB Value (84,97,75), 14.15% of RGB Value (123,137,97) and 5.55% of RGB value (206,193,141),as per sample approved by AGE(I) for building of height upto 7.50 metre, over and including a coat of alkali resistance prime,r complete all as specified and directed.Note- (i)The rate quotedby contractor is deemed to include preparation of surfaces and necessary scaffolding for painting upto required height. |
| 6 | Material and labour for Gypsum board 12 mm thick in ceiling fixed with screws as per manufacturers instructions,including anodised aluminium snap grid frame work 605 mm x 605 mm for false ceiling and hangers 6 mm dia GI (upto 1200 mm length) withlevel adjusting mechanism, fixed to roof slabs by means of ceilling cleats made out of GI flat 40 mm x 3 mm, 60 mm long and expansion hold fasteners 12.5 mm dia 40mm long complete all as specified and directed. |
| 7 | Supply and fixing factory made pressed steel frames for doors with two rebates, of size 105 mm x 60mm, made out of 1.25mmthick sheet, including PCC 1:3:6 type C-0 filling, one shop coat primer andnecessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and directed. |
| 8 | Supply and fixing flush shutters 30mm thick, solid core construction with block board core and plywood face panels commercial type on both sides, both faces covered with 0.6mm thick decorative face veneer, duly provided with 6mm thick Teakwood lipping on edges, fitted to chowkats, complete all as specified & directed. |
| 9 | Supply and fixingFactory made box type steel window with pintol hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and with glazing bars dovetailed or welded, including provision of grill as per drawing and with one shop coat of zinc chromate primer complete all as specified and shown on Drawing No CEAF/STD-184-2012 Sheets 1/3, 2/3 & 3/3. |
| 10 | Supply and fixing, 150 mm long, extruded aluminium alloy handles, fabricated type, anodized, complete all as specified and directed. |
| 11 | Supply and fixing Aluminium alloy, anodised, sliding door bolts 250mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy 12mm dia, complete all as specified and directed. |
| 12 | Supply and fixing 140 mm door stopper of aluminium alloy body and tongue , anodised, with hard drawn steel spring fixed in door, complete all as specified and directed. |
| 13 | Supply and fixing 150 mm long aluminium anodized, barrel tower bolt of extruded section, complete all as specified and directed. |
| 14 | Supply and fixing powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections as approved, of approved make, conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom andsideswithrequiredEPDM, rubber/ neoprene gasket etc. Aluminium sections shall be smooth, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and as directed. Note:- Weigth of Aluminium section only shall be payable and the cost of other accessories mentioned in the description shall be deemed to be included in the quoted rate of this item. |
| 15 | Supply and fixing Anodised Aluminium door shutter, powder coated with minimum thickness of powder coating 50 micron,aluminium section weighing 0.9 to 1.4kg / RM including necessary Joining Cleats, Glazing Clips, Rubber Packing, Rubber Neoprene Packing, Screws, Anodised Aluminium Snap Beading, Anodised Aluminium Fittings in each shutter such as Handles, 200 mm Long [2 Nos], Hinges , 100 mm long vertical4 lever mortice door lock etc, complete all as specified and as directed. |
| 16 | Supply and fixing plain sheet glass 5.5 mm thick, ordinary quality, not exceeding 0.50 Sqm each pane, and glazing with oil putty and securing pins, complete all as specified and directed. |
| 17 | Supply and fixing Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box for shutter of weight upto 30kg, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed, complete all as specified and directed. |
| 18 | Material and labour applying two coats of synthetic enamel paint over and including a coat of pink primer, on new wooden surfaces over 10cm width or girth, including preparation of wooden surface, complete all as specified and directed. |
| 19 | Material and labour for RCC 1:1.5:3 type A-1 using 20 mm gradded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 metre span, chajja, complete all as specified and directed. |
| 20 | Material and Labour for TMT steel bars, 10 mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. |
| 21 | Material and Labour for mild steel TMT bars 8 mm dia and over upto 10 mm dia as in stirrups, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified. |
| 22 | Material and labour for Formwork to concrete foundations, footings, bases of columns, raft & raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work, vertical or to batter, flat fair finished concrete surfaces complete all as specified and directed. |
| 23 | Material and labour for 40mm thick damp proof course in plain cement concrete1:2:4, type B-0 (using 12.5 mm graded crushed stone aggregate), to horizontal or vertical surfaces, including necessary formwork,complete all as specified and directed. |
| 24 | PLATFORM WORK |
| 25 | Surface excavation in soft/loose soil not exceeding 30 cm deepand averaging 15 cm and getting out complete, all as specified. |
| 26 | Hardcore of gauge not exceeding 63 mm of broken stone or boulders, deposited, spread, levelled in layers not exceeding 15 cm thick ,watered and rammed to a true surface, complete all as specified. |
| 27 | Material and labour for 150 mm thick plain cement concrete 1:5:10type E-2 using 40 mm graded crushed stone aggregate as in sub base of floors, complete all as specified and directed. |
| 28 | Material and labour for 100 mm thick plain cement concrete (1:2:4)type B-2 using 40 mm graded crushed stone aggregates as in floor, finished the surface even & fair, complete all as specified and directed. |
| 29 | DUCT WORK |
| 30 | Material and labour for PCC 1:3:6, Type C-2 using 40 mm graded stone aggregates as in surface channel/ drains including rounding to any radius,weathering, slightly rounded or chamfered angles and throating as directed including provision of necessary form work, complete all as specified. |
| 31 | Material and labour for PCC 1:2:4, Type B-0 using 12.5 mm graded stone aggregates as in surface channel/ drainsincluding rounding to any radius,weathering, slightly rounded or chamfered angles and throating as directed including provision of necessary form work, complete all as specified. |
| 32 | Supply and Fixing Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165, complete all as specified and directed. |
| 33 | Supply and fixing Mild steel plates, plain or chequered, 5 mm thick or over in thickness in available sizes, Fe-290 (Gde E165), complete all as specified and directed. |
| 34 | FIRE ALARM SYSTEM |
| 35 | Supply, install, test and commissioning Fire alarm control panel complying with BSEN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detectorand modules, complete all as specified and directed. |
| 36 | Supply, install, test and commissioning Module Detectors Complying with and type certified to EN - 45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360, complete all as specified and directed. |
| 37 | Supply, install, test and commissioningFire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB500 mtrs range, complete all as specified and directed. |
| 38 | Supply and fixing Addressable manual call point break glass type and resettable type with alarm LED, complete all as specified and directed. |
| 39 | Supply and fixing electric Audio visual alarm/hooter circuit with acknowledgement button housed in a cabinetrequired to indicate the commercial failure, suitable for 230 volt 50 Hz, complete all as specified and directed. |
| 40 | Supply and fixing Rigid non-metallic PVC conduit 20 mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed. |
| 41 | Material and labour for circuit/submain wiring alongwith earth wire in PVC conduit with 1.5 Sqmm sizes of FRLSPVC insulated copper conductor, single core cable in surface/ recessed as required, complete all as specified and directed |
| 42 | Supply, fixing and testing ceiling fan 1200 mm sweep, metallic body, metallic blades, copper wound, 230 volts, single phase, high speed, heavy duty, operating on single phase AC supply, including provision of PVC insulated flexible copper wire 1.5 Sqmm three corefrom ceiling rose to fan for giving connection,complete all as specified and directed. |
| 43 | AIR CONDITIONING AND REFRIGERATION |
| 44 | Supply, installation, testing and commissioning, High wall split type AC unit of capacity 2 TR, with copper piping and condenser, dual inverter, with minimum 5 star rating, electric driven, single phase, indoor and outdoor unit, with cordless remote control and with in-built air ionizer and plasma filter for better indoor air quality, necessary suction and discharge copper pipelines from inner units duly insulated, including welding/ brazing to make leak proof, 15 mm bore PVC pipe of superior quality for drainage of condensed water, including cutting chases for refrigeration piping, connection cable, drain pipeetc in brick wall, necessory brackets/suitable stand for mounting outdoor /indooor units as per manufacturer\"s instructions and providing electrical connections and electric cable from inner to outer unit complete all as specified and directed. Make - Hitachi, Voltas, Blue star, Carrier Deccan. |
| 45 | Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed. |
| 46 | Material and labour for Sub Main Wiring (in replacement) with two single core 4 Sqmm (nominal area) multi stranded copper conductor FRLSH PVC insulated and unsheathed colour code cables, drawn in and including non-metalic rigid PVC conduit, heavy duty of 25 mm dia, including standard fittings such as Tees, junction, bands etc., conduit concealed in wall & fixed on ceiling with suitable clamps with and including one run of continuous multi stranded copper conductor 4 Sqmm (nominal area) FRLSH PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 4 Sqmm main cable + one run of 4 Sqmm cable for earth continuity and PVC conduit shall be measured as one unit/one Running Metre.(ii)Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required. |
| 47 | Supply and fixing sheet metal enclosure single pole and neutral , with two pin and earth plug and socket complete with one single pole MCB20 Amp, complete all as specified and directed |
| 48 | EXTERNAL ELECTRIFICATION WORKS |
| 49 | Shifting of Indoor type transformer 300 KVA to a distance not exceeding15.00 Kilometres from power house/any other place as directed, to the required place as directed, including disconnecting all electric connections and re-connecting after re-istallation of transformer, including all necessary transportaion etc, complete all as specified and directed. |
| 50 | Shifting of Indoor type voltage stabilizer 300 KVA to a distance not exceeding15.00 Kilometres from power house/any other place as directed, to the required place as directed, including disconnecting all electric connections and re-connecting after re-istallation of Voltage Stabilizer, including all necessary transportaion etc, complete all as specified and directed. |
| 51 | Shifting of Indoor type transformer 800 KVA to a distance not exceeding15.00 Kilometres from power house/any other place as directed, to the required place as directed, including disconnecting all electric connections and re-connecting after re-istallation of transformer, including all necessary transportaion etc, complete all as specified and directed. |
| 52 | Shifting of Indoor type voltage stabilizer 800 KVA to a distance not exceeding15.00 Kilometres from power house/any other place as directed, to the required place as directed, including disconnecting all electric connections and re-connecting after re-istallation of Voltage Stabilizer, including all necessary transportaion etc, complete all as specified and directed. |
| 53 | Supply, installation, testing and commissioningfactory made, CPRI approved LT panel board, cubical, outdoor type, 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated copper bus bar of suitable rating installed on procelain/ SMC insulators. The panel shall be dust and vermin proof with IP -65 class protection, inbuilt onload change over switch 630 Amp and made of 3.15 mm CRCA MS sheet, powder coated,finished with three coats of synthetic enamel paint over one coat of red oxide primer, rear opening type with a provisionfor cable entry, closing/ locking arrangement, including internal wiring with PVC insulated solid copper conductor FRLS cable, 1100 volts grade of appropriate size, mounted on angle base frame 50 mm x50 mm x 6 mm, including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size,complete all as specified and directed , with the following fitments/requirements as mentioned here-in-after against ser No 6.06:- |
| 54 | (a)Air Circut Breaker 1250 Amp, 50 KA thermal type 4 pole 415 volt incoming -01 No.(b) MCCB 4 pole 415 volt 400 amp rating braking capacity 36 KA = 02 Nos (c) MCCB 4 pole 415 volt 250 amp rating braking capacity 36 KA =01 No out going,(d) Bus bar: Providing suitable size ofcopper Bus bar electrolytic grade of suitable rating with coloured heat shrinkable insulated sleeves 415 volts as per IS, of suitable size mounted on DMC/epoxy insulators(e) Digital voltmeter with built- in selector switch -01 No, (f) Digital Ammeter with built -in selector switch -01 No, (g) CTs 1250/5A - 03 Nos,(h) LED type, RYB indicating lamps with 2 Amps MCB\"s-01 Set |
| 55 | Supply, Installation, testing and commissioning online 300 KVA UPS 415 volts, based on Digital Signal Processing (DSP) Technology type with Inbuilt Isolation Transformer and passive harmonic filter, Reverse Phase sequence protection & Correction type,complete with battery bank for more than 30 min backup time, 12 volt SFM200 AH batteries 120 Noson suitable rack stand including seamless changeover of commercial supply to DG set supply, Provn of SNMP card & LCD displayand vice versa with the following specifications/requirements as mentioned here-in-after against ser No 6.08 to 6.17:- |
| 56 | (A) INPUT :-(i)Input voltage from 380 Volts to 415 Volts (+-15%). (ii) Rectifier capacity - Rectifier should be able to charge the battery banks in fully discharged condition and also supply power in full load condition. (iii) DC Voltage ripple at battery bank - < 1%. (iv)Rated voltage - 400 volts 3 phase 50 Hz. (v) Voltage tolerance -+/-15%. (vi) Rated frequency -50 Hz . (vii) Frequency tolerance -+ 5 Hz. (viii) Input Power factor - >0.99. (ix) Input Current Harmonics THDI - =3%. (ix) Rectifier technology - IGBT Based. |
| 57 | (B) OUTPUT :-(i) Inverter Technology - IGBT based PWM Inverter -IGBT based PWM Inverter. (ii) Rated voltage - 400 volts 3 phase and neutral. (iii) Output Power factor - 0.9. (iv) Voltage tolerance -+/- 1%. (v) Voltage regulation - \"+/-1% under steady state condition, \"+/-Not to exceed +5% in Dynamic stage. (vi) Recovery time -<20 m sec Conform to the standard EN 62040-3, class 1. (vii) Rated Frequency - 50 Hz. (viii) Frequency tolerance - +/-0.50 Hz. (ix) Overload capacity - 110 % of rated capacity for 60 min, 125 % of rated capacity for 10 min, 150 % of rated capacity for 60 sec. |
| 58 | (C) Overall efficiency with isolation transformer and without battery bank -(i) At 100% rated capacity at 0.9 lag pf - 93%. (ii) At 75% rated capacity at 0.9lag pf - 94%. (iii) At 50% rated capacity at 0.9 lag pf - 94%. (iv) At 25% rated capacity at 0.9 lag pf - 93%. No Load Loss - <4 % of rated Capacity. Total efficiency >90%. |
| 59 | (D) Wave form (Harmonic Filter)- (i) Wave form -Sinusoidal. (ii) Output voltage Harmonic distortion = a. With Linear load - <2%, b.With Non linear load - <3%, c. Crest factor - 3:1 |
| 60 | (E) Features to be provided- (i) Manual by pass switch. (ii) Static bypass - To be provided for individual UPS module. (iii) Capacity of Static Bypass - Equal to UPS capacity. (iv) Manual bypass - To be provided for individual UPS module. (v) Provn of emergency Trip. (vi) Output voltage adjustment - + 15 volts. (vii) Battery circuit breaker - To be provided on Rack of Battery Bank. (xiii) Provn of On line temperature display. (ix) Provn of On line battery bank monitoring & battery bank alert. |
| 61 | (F) Alarm Indication and Trips - (i) Load on mains (ii) Loan on batteries (iii) Battery voltage low (iv) Low input frequency (v) Equipment over temperature(vi) Equipment overload(vii) Battery output breaker open. |
| 62 | (G) LCD Display - Provn of LCD ruggedized display in crew room at a distance 100 mtr using STP communication cable so that the operator can easily monitor the parameters of the UPStoprovidethefollowing measurement options -(a) Voltage –Input Rectifier (1-2-3 Phase / Neutral), Input by pass (1-2-3 Phase / Neutral), UPS output (1-2-3 Phase / Neutral), Battery (b) Current – UPS input (Phase 1-2-3), UPS output (Phase 1-2-3), Battery charging / discharging (c) Frequency – UPS Input, UPS Output. (d) Battery – Remaining back-up time (in minutes) capacity. (e) Power - UPS active output (Phase 1-2-3), UPS load % (Phase 1-2-3). (f) Ambient temperature - 0 deg. C to 40 deg.C. (g) Ambient Relative Humidity - 0-95% non-condensing. |
| 63 | (H) Protection(i) Provn of Protection against Over voltage, Over current and short circuit current(ii) Current limiting features (iii)Suitable protection for DC filter capacitors (iv) HRC fuses for control circuits (v) Inverter tripping without fuse failure on output short circuit . (vi) Fast acting semi conductor fuses. |
| 64 | (J) Communication features: The UPS shall have the following features: 1. RS 232 /485 serial port 2. LAN Connectivity interface, 3.Noise level at 1 meter 72 dBA |
| 65 | Notes for srl item No 6.06 :- (i) Warranty for installation shall be for one year and warranty shall start after date of successful commissioning and handing over the equipment to user unit. (ii) Warranty shall include free replacement of spares like fuses of different rating used in UPS, capacitors, faulty cards etc. (iii) Any unserviceability shall be counted in hrs and must be attended within minimum possible time of reporting fault to the supplier. Unserviceability beyond 12 hrs during warranty period shall be accumulatedand counted for extension for the period of unserviceability. |
| 66 | Material and labour for providing chemical earthingof advance system of Copper pipe Chemrode 3 mtrs long 50mm dia and inner strip of copper as earthing electrodes and filled with conducting concrete back fill compounds with the permanent sealings at both the ends. Top of the earth electrode shall be compressed to form an extended lead with 2 holes for connecting the strip/wire to the load. To ensure the moisture content and electrical conductivity,each earthing pit shall be provided with minimum 03 bags of 25 kgs chemical compound. An arrangement for connection of copper cable suitable size from rod to be made with given Terminal point with SS Nut Bolts, provision of polymer chamber with cover, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil, the desired value of resistance shouldbe less than 1 Ohm, Entire work will be executed by OEM, complete all as specified and as directed. |
| 67 | Supply, laying, jointing, testing and commissioningLow Tension (LT)XLPE insulated andarmoured, heavy duty, electric power cable, cross sectional area 300 Sqmm 3.5 core aluminum conductor 1100 volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, alongpolesorpassing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note:Excavation & earthork, sand cushioning and bricks for protection of cable shall be measured and paid separately. |
| 68 | Clean dry sand laid in trenches/ducts for bedding andcushioning to cable, 8cm in depth before laying the cable and 15 cm in depth after laying the cable including spreading, levelling and consolidation complete all as specified and directed. Note : Consolidated/punned thickness of 18 cm (overall) shall be measured for payment purpose. |
| 69 | Supply and layingwell burnt sub class \"B\" bricksfor cable protection laid flat ,length wise, perpendicular to the axis of cable, complete all as specified. |
| 70 | Supply and laying / fixing , GI pipe light grade 100 mm dia for cable protection fixed to pole/wall or laid under floor/ road/ pavement, including MS clamp/nuts & bolts etc complete all as specified and directed. |
| 71 | Supply and fixing Flexiblcable copper conductor single core multy stranded, electric power cables (heavy duty) 1100 Volts grade of size 185 Sqmm Single Core with necessary fixing arrangement as required at site, complete all as specified and directed. |
| 72 | Supply, installation, testing and commissioningfactory made, CPRI approved LT panel board, cubical, outdoor type, 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated copper bus bar of suitable rating installed on procelain/ SMC insulators. The panel shall be dust and vermin proof with IP -65 class protection, inbuilt onload change over switch 630 Amp and made of 3.15 mm CRCA MS sheet, powder coated,finished with three coats of synthetic enamel paint over one coat of red oxide primer, rear opening type with a provisionfor cable entery, closing/ locking arrangement, including internal wiring with PVC insulated solid copper conductor FRLS cable, 1100 volts grade of appropriate size, mounted on angle base frame 50 mm x50 mm x 6 mm, including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size,complete all as specified and directed , with the following fitments/requirements as mentioned here-in-after against ser No 6.25 to 6.54) :- |
| 73 | (a)MCCB 4 pole 415 volt 630 amp rating braking capacity 36 KA incoming (Adjustable Overload 40-100%) -01 No.(b) MCCB 4 pole 415 volt 400 amp rating braking capacity 36 KA = 02 Nos and MCCB 4 pole 415 volt 250 amp rating braking capacity 36 KA = 01 No out going,(c) Bus bar: Providing suitable size ofcopper Bus bar electrolytic grade of suitable rating with coloured heat shrinkable insulated sleeves 415 volts as per IS of suitable size mounted on DMC/epoxy insulators.(d) Digital voltmeter with built in selector switch -01 No, (e) Digital Ammeter with built in selector switch -01 No, (f) LED type, RYB indicating lamps with 2 Amps MCB\"s-01 Set |
| 74 | Supply and fixing Surge protection device 415 volts four pole type I + II complete all as specified and directed |
| 75 | Supply and fixing flange male & female socket and plug single pole made up of copper with silver coating, 400 Amps rating suitable to feed load to CEC as per site requirment complete all as specified and directed. |
| 76 | Supply,installing,testing&commissioningHT 11 KV, 250 MVA, 400 Amps 25 KA for 1 sec HT vacum circuit breaker panel for incomer, confirming to latest IEC,IAC25 KA for 1 Sec front accessed comprising of following - (Make :CG/ABB/SCHNEIDER) - |
| 77 | (a) 400 A continous rated electrolytic copper bus bar droppers and bus bars shall be insulated with full system voltage sleeves of Reychem or equivalent make as approved. |
| 78 | (b) Cassette mounted vacum circuit breaker as per latest IEC. Vacum circuit breaker shall have Epoxy resin cast V.T. 3 Ph, D/O type 11 KV/Sqrt.3/110V/Sqrt.3, Class-1 Burden-100VA and Epoxy resin cast C.T. 400-200/5-5,CL-1/5P10, Burden-15VA. |
| 79 | (c) Motorized spring charging mechanism with intergalspring charging handle for manual spring charge. |
| 80 | (d) Interpanel epoxy barrier to restrictpropagation from one panel to other. |
| 81 | (e) Provn of Power pack with battery 24 Volts |
| 82 | (f)Accessories like local remote switch breaker control switch (T-N-C) space heater with thermostat DC & AC control circuit through MCB indicating lamps for RYB, spring charge DC suppply healthy, breaker ON/OFF breaker in Service / Test. |
| 83 | (g)Multifunction meter with RS 485 port model no EM 6400 of Make CONSERV |
| 84 | (h)Digital Ammeter master trip relay and antipumping relay. |
| 85 | (j) Comprehensive numerical protection relay with MODBUS compatible for directional and non directional O/C E/F U/VO/V protectionHaving following additional facilities -(Make : CG/ABB/AREVA) |
| 86 | (i)Trip ckt supervision |
| 87 | (ii) Disturbance recording |
| 88 | (iii)Event log with date and time |
| 89 | (iv)Measurement and control feature |
| 90 | (k)Panel shall also have additional facility like :- |
| 91 | (i) Continuous rated closed and tripping coil. |
| 92 | (ii)Fully internal arc type tested ( 26.3 KA for 3 sec ) as per latest IEC 62271-200 |
| 93 | (iii)Vacum bottle shall be epoxy encapsulated |
| 94 | (iv) Racking in/out manual closing tripping of CB with compartment door closed. |
| 95 | (v) Breaker shall be provided with following contacts :- |
| 96 | (a)Auxiliary switch with 4 NO + 4 NC mounted on the draw out portion switchgear . |
| 97 | (b)Position swithces with3 NO + 1 NC contacts for each position in service and test. |
| 98 | Make \"CROMPTON GREEVES/ ABB/ SCHNEIDER. |
| 99 | NOTE : (i) Pre-dispatch inspection of VCB shall be carried out by rep of Accepting Officer. All arrangements for the same shall be made by the contractor |
| 100 | (ii) Drawing for VCB shall be approved by AGE(I) before placement of order. |
| 101 | (iii) Any modifications asrequired for installation of HT panels shall be carried out by cotractor at no extra cost to Govt. |
| 102 | (iv) Pre-commissioning inspection shall be carried out by SEI / rep of Accepting officer before completion of work |
| 103 | Supply, laying, jointing, testing and commissioning of High Tension (HT), 11000Volts (earthed) grade, XLPE insulated, screened, PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 95Sqmm, 3core under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and directed.Note : Excavation and earth work, sand cushioning and precast concrete cable cover/bricks for protection of cable shall be measured and paid separately. |
| 104 | Supply, jointing & testing, outdoor end termination joint kit (Heat shrinkable) complete with jointing material and accessories suitable for 11KV grade, HT, underground XLPE insulated armoured aluminium conductor, 3 core95 Sqmm size cable, complete all as specified and directed. |
| 105 | Supply, jointing & testing, indoor end termination joint kit (Heat shrinkable) complete with jointing material and accessories suitable for 11KV grade, HT, underground XLPE insulated armoured aluminium conductor, 3 core95 Sqmm size cable, complete all as specified and directed. |
| 106 | Supply, fixing, connecting, commissioning and testing power factor improvement panel of capacity 240 KVAR, testing conforming to IEC, including interconnection with LT panel with appropriate size of electric cable for transformer (Indoor) type panel, factory made, weather proof , dust and vermin proof, suitable forhumidity up to 95%, Average daily temperature: +35°C max, Ambient temperature: -5°C to 45°C, Maximum altitude: 2000 m,1100 V/660 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 14 SWG MS sheet welded on 40 mm x 40 mmx 3 mm angle iron frame / base of appropriate size and having four Nos angle ironlegs made out of 40 mm x 40 mmx 6mm , 60 cm long angle iron below frame with front door and back opening having locking arrangement, prewired with copper conductor PVC insulated flexible wire of size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with Siemensgrey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:3:6 of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles , all as specified and directed, including all other electric incoming and outgoing connections with PVC insulated multi stranded flexible copperNYVIN cable of suitable size and PVC flexible conduit medium quality as required , comprising of the following/requirements as mentioned here-in-after against ser No 6.59 to 6.71:- |
| 107 | (A) Insulated Bus bar of aluminium of suitable capacity for three phase, fixed on insulators. Busbar shall be PVC sleeved with Red, Yellow & Blue Colour. Bus bar support shall be of SMC/DMC, Rated Impulse Withstand Voltage -01 Set |
| 108 | ( B) Incommer MCCB of suitable capacity, Electronic trip unit Micrologic 2.3 (LSI protection) Three Pole, Ics = 100% Icu as per IEC, Adjustable thermal setting 0.7 - 1 x In, Class II Front Face, Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier.Make:- Schneider/ Siemens / ABB -1 No. |
| 109 | (C) Capacitor 240 KVAR(20+20+50+50+50+50) , Metallised polypropylene filmwith Zn/Al alloy Can typecapacitor bankof 480 rated volt, Maximum over current : 1.8 In,Overpressure protection,Discharge resistance 50 V - 1 min, Capacitance Tolerance -5%, +10%, Maximum permissible over current (with thermal protection included)1.43 In ,Maximum permissible over voltage 1.1 x Un, 8 h every 24 h, of rated 480 volt with detuned Reactor of de-tuning factor (P) 7% and suitable output of 240 KVAR at 440 Volt, Overheating protection by thermostatconfirming toIS .Make – Siemens/Schneider/ ABB |
| 110 | (D) Var Plus logic APFC relay-Advanced Range (Ref:-VPL06N)VPL06, 6 step, LCD Display , 90V - 550V 50/60Hz 1A/5A with RS485,( 144x144mm ). Make:Siemens/Schneider/ ABB/Beluk-01 No |
| 111 | (F) CT 250/5A , 10 V.A, CL:1.0, Resin Cast,CT Secondary wire Size shall be 2.5 Sq mm.Make : Kalpa /AE/ L&T/Kappa -03 Nos |
| 112 | (F)Accessories for 20 KVAR capacitor Bank :- |
| 113 | (1)Capacitor Duty Contactor(AC6b) 20 KVAR with damping resistors which limit in rush Current, 440 volt ,3ph,50 Hz, Coil-220 Vac, Make – L&T / Seimens/ABB/ Schneider-02 No |
| 114 | (2) MCB, TP,25 Amp, 10 KA, D-Curve, Make : Siemens/ ABB/Schneider-02 Nos |
| 115 | (G)Accessories for 50 KVAR capacitor Bank :- |
| 116 | (1)Capacitor Duty Contactor(AC6b) 50 KVAR with damping resistors which limit in rush Current,440 volt ,3ph,50 Hz, Coil-220 Vac, Make – L&T / Seimens/ABB/ Schneider-01 No |
| 117 | (2) MCB, TP,100 Amp, 10 KA, D-Curve, Make : Siemens/ ABB/Schneider-01 No |
| 118 | (H) Ventilating fans of required size to dissipiate the heat liberated by capacitor units complete with automatic switching ON and OFF of fans depending upon the temperature of the Panel 230 V AC, 2650 rpm,160 Cu.m/h, Flying leads |
| 119 | (J) All accessories prewired with suitable size copper conductor cable insulated with fibre glass insulation to withstand high temperature, housed in cubical panel (CPRI approved) made out of 2 mm thick MS sheet factory made as per IEC 62208 duly powder coated, front and rear door openable with locking arrangement complete with IK 10 protection against mechanical Shocks as per IEC, foundation as required or recommended by manufacturer. Make of APFC Panel: SchneiderCG/BHEL/SIEMENS. Note: APFC Panel shall be manufacturedby original manufacturer only i.e. Schneider/CG/BHEL/SIEMENS only. The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf and the panels so manufactured will not be accepted. The panels manufactured by original manufacturer only will be accepted & factory inspection will be done at original manufacturer plant only. |
| 120 | Material and labour for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron strip of size 32mmx6mm thick (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm dia bore, and watering pipe 20mm dia bore GI medium grade with funnel & wire meshincluding all necessary excavation & earth work,PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete all as specified and directed.Note(s) :-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii)PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately.(iv)Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. |
| 121 | Material and labour for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron wire 4mm dia (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm dia bore, and watering pipe 20mm dia bore GI medium grade with funnel & wire meshincluding all necessary excavation & earth work,PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete all as specified and directed.Note(s) :-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii)PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately.(iv)Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. |
| 122 | Material and labour for Copper strip 25 mm x 3 mm with saddles and fixing screws on roof/floor, complete all as spceified and directed by. |
| 123 | Material and labour for GI strip 32 mm x 6 mm fixing at site, complete all as spceified and directed. |
| 124 | ROLLING SHUTTER WORK |
| 125 | Supply and fixing steel rolling shutter gear operated, push or pull manual type, 1.25 mm thick, without ball bearing,including top cover, anchoring rod, hasp and staple and one shop coatprimer, erected in position as indicated,complete all as specified and directed. |
| 126 | COMMOM ITEMS FOR BUILDING WORK, PLATFORM WORK, DUCT WORK, EXTERNAL ELECTRIFICATION AND ROLLING SHUTTER |
| 127 | Excavation in trenches in soft/loose soil not exceeding 1.50 meter wide and not exceeding 1.5 meter in depth; for foundations etc or for cesspits, manholes,not exceeding 10 Sqm on plan, for laying of cables and foundation of poles etc, trimming andgetting out complete, all as specified. |
| 128 | Material and labour for plain cement concrete 1:3:6type D-2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete, complete all as specified and directed. |
| 129 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick each as in soft/loose soil, complete all as specified and directed. |
| 130 | Removingof surplussoil / excavated material to a distance exceeding 50 metre butnot exceeding 100 metre and depositing where directed complete all as specified. |
| 131 | Removal of surplus excavation soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 132 | Material and labourfor brickwork with usingsubclass \"B\" old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6),complete all as specified and directed. |
| 133 | Material and labour forrendering 15mm thick in cement mortar (1:4),on brick/concrete surfaces of walls, finished even and fair without using extra cement , complete all as specified and directed. |
| 134 | Material and labour for preparation of newly plastered surfaces of wall and applying two coats of cement based paint, complete all as specified and directed. |
| 135 | Material and labour, applying two coats of synthetic enamel paint over and including a coat of red oxide primer, on new steel surfaces over 10cm width or girth, including preparation of steel surface, complete all as specified and directed. |