Tender For 8730 Repair, Maintenance Of Ceiling Fans, Exhaust Fans, Wall Mounted Fans, Air Circulators, Pedestal Fans, Geysers, Solar Water Heaters And Other Misc Items At Af Station Bareilly, bareilly-Uttar Pradesh

Military Engineer Services-MES has published Tender For 8730 Repair, Maintenance Of Ceiling Fans, Exhaust Fans, Wall Mounted Fans, Air Circulators, Pedestal Fans, Geysers, Solar Water Heaters And Other Misc Items At Af Station Bareilly. Submission Date for this Tender is 26-06-2023. Electrical Maintenance Tenders in bareilly Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

37942035
Corrigendum : Tender For 8730 Repair, Maintenance Of Ceiling Fans, Exhaust Fans, Wall Mounted Fans, Air Circulators, Pedestal Fans, Geysers, Solar Water Heaters And Other Misc Items At Af Station Bareilly
Open Tender
Indian
Uttar Pradesh
bareilly
26-06-2023

Tender Details

8730 Repair, Maintenance Of Ceiling Fans, Exhaust Fans, Wall Mounted Fans, Air Circulators, Pedestal Fans, Geysers, Solar Water Heaters And Other Misc Items At Af Station Bareilly

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINTENANCE OF CEILING FANS, EXHAUST FANS, WALL MOUNTED FANS, AIR CIRCULATORS, PEDESTAL FANS, GEYSERS, SOLAR WATER HEATERS AND OTHER MISC ITEMS AT AF STATION BAREILLY
Sl. No. Item Description
1Disconnecting carefully electric connections, sealing of electric connections with adhesive tape and taking down unserviceable ceiling fan/ exhaust fan/ wall mounted fan/ air circulator fan/ pedestal fan of any size from ceiling or wall or the like and removing the same to MES store yard for servicing/ painting etc and refixing & reconnecting the same after repairs in its original location complete including replacement of unserviceable PVC 2 pole connector all as specified and directed.
2M&L for dismantling the ceiling fan 1200mm sweep, 230 Volts, 50 Hz of any make, cutting and removing of burnt winding of fan motor and re-winding the same with appropriate gauge super enameled copper winding wire with and including necessary allied works such as insulation material, air drying insulation, varnishing, cotton tape lathered film paper, spacers, sleeves and necessary testing and commissioning after re-assembling of fan complete all as specified and as directed.
3All as per Item No. 2 herein before but for Ceiling fan 1400 mm sweep.
4All as per Item No. 2 herein before but for Exhaust fan 230 to 300 mm sweep.
5All as per Item No. 2 herein before but for Exhaust fan 350 to 380 mm sweep.
6All as per Item No. 2 herein before but for Exhaust fan 400 to 450 mm sweep.
7All as per Item No. 2 herein before but for Flame proof Exhaust fan 300 to 350 mm sweep.
8All as per Item No. 2 herein before but for Wall mounted fan 400 to 450 mm sweep.
9All as per Item No. 2 herein before but for Flame proof wall mounted fan 400 to 450 mm sweep.
10All as per Item No. 2 herein before but for Air circulator fan or pedestal fan up to 600 mm sweep.
11All as per Item No. 2 herein before but for Flame proof air circulator fan or pedestal fan up to 600 mm sweep.
12M&L for servicing and overhauling of ceiling fan 1200mm sweep including cleaning with cleaning agent, greasing, replacement of bushes, capacitor, bearings etc. (if required), replacing unserviceable minor spares like split pins, steel strip holding clamps & rubber pad packing of capacitors, tightening the nut-bolts, screws etc. and making electric connections complete including necessary T&P all as specified and as directed. [Notes: (i) Supply only Ball bearings, bushes & capacitors shall be measured and paid separately (ii) Repair and serving work to be carried out in the store yard or in office premises under the close supervision of the executives.]
13All as per Item No. 12 herein before but for Ceiling fan 1400 mm sweep.
14All as per Item No. 12 herein before but for Exhaust fan 230 to 300 mm sweep.
15All as per Item No. 12 herein before but for Exhaust fan 350 to 380 mm sweep.
16All as per Item No. 12 herein before but for Exhaust fan 400 to 450 mm sweep.
17All as per Item No. 12 herein before but for Flame proof Exhaust fan 300 to 350 mm sweep.
18All as per Item No. 12 herein before but for Wall mounted fan 400 to 450 mm sweep.
19All as per Item No. 12 herein before but for Flame proof wall mounted fan 400 to 450 mm sweep.
20All as per Item No. 12 herein before but for Air circulator fan or pedestal fan up to 600 mm sweep.
21All as per Item No. 12 herein before but for Flame proof air circulator fan or pedestal fan up to 600 mm sweep.
22Supply only Ball bearing 6201. [Make: SKF/ NBC/ NSK/ NACHI].
23Supply only Ball bearing 6202. [Make: SKF/ NBC/ NSK/ NACHI].
24Supply only Ball bearing 6203. [Make: SKF/ NBC/ NSK/ NACHI].
25Supply only Gun metal bush any type as required.
26Supply only Capacitor 2.50 MFD, 50 Hz. [Make: Epcos/ Tibcon/ Havells/ Crompton].
27Supply only Capacitor 4 MFD, 50 Hz. [Make: Epcos/ Tibcon/ Havells/ Crompton].
28S&F as in replacement, heavy duty rubber reel suitable for hanging rod of ceiling fan complete all as directed.
29S&F as in replacement 0.50 Sq.mm size twin core, PVC insulated copper conductor flexible cord cable as in electric connection for ceiling/ exhaust fan complete all as specified and directed.
30S&F as in replacement PVC three core flexible wire with copper conductor of size 23/0.0076" confirmingto IS-434 from connector of ceiling/ exhaust fan to the mains complete all as specified and as directed.
31S&F as in replacement heavy duty mild steel socket along with split pin locking screw as required for coupling fan motor and hanging down rod of ceiling fan complete all as specified and directed.
32S&F in repairs fan regulator electronic socket step type, 100 Watts, 230 Volts, flush type one module all as specified. [Make: Anchor/ Cona/ GM/ Leader]
33S&F in repairs fan regulator electronic socket step type, 100 Watts, 230 Volts, flush type two module all as specified. [Make: Anchor/ Cona/ GM/ Leader]
34S&F in repairs modular step type electronic fan regulator 2 module, 120 Watt, 230 V complete all as specified. [Make: Anchor/ Cona/ GM/ Leader]
35S&F in repairs ceiling rose PVC/ Poly carbonate isolated body, three terminal, 230 Volts AC complete all as specified. [Make: Anchor/ Cona/ GM/ Leader]
36S&F in repairs single pole and neutral enclosure with two pin and earth plug and socket with one single pole MCB 20 Amps 240 Volts complete with plastic cover all as directed. [Make: L&T/ Schneider/ Legrand/ ABB]
37S&F as in replacement ‘U’ clamp including nut-bolt, washers, rubber reel, split pin and check nut etc. suitable for ceiling fan any size complete all as specified and directed.
38S&F as in replacement down rod (Hanging Rod) of 450mm long fabricated out of 15 mm bore GI tubing duly threaded for check nut and drilling for split pin and U clamps as necessary for ceiling fan of any size complete all as directed.
39S&F as in replacement down rod (Hanging Rod) of length exc. 450mm but n.exc. 1000mm fabricated out of 15 mm bore GI tubing duly threaded for check nut and drilling for split pin and U clamps as necessary for ceiling fan of any size complete all as directed.
40S&F as in replacement PVC insulated, PVC sheathed, 2.50 Sq.mm size, single core, multi-stranded copper conductor cable (FR-LSH) complete all as specified and directed.
41S&F as in replacement PVC insulated, PVC sheathed, 4 Sq.mm size, single core, multi-stranded copper conductor cable (FR-LSH) complete all as specified and directed.
42S&F Exhaust fan 300mm sweep, single phase 230V, AC single phase metal body with louvers, heavy dutyincluding electric connection from ceiling rose to fan connector with PVC insulated 3 core copper cable of size 0.75 sq.mm complete including taking down existing unserviceable fan and depositing to MES store all as specified and directed. [Make: Model No. "Ventil Air - DB" of make: Havells or equivalent in Almonard/ Bajaj/ Crompton]
43S&F 400mm sweep, wall mounted cabin fan 1350 RPM, single phase, 230 volts AC, 50 Hz, complete with pull cord for speed control & oscillating mechanism, necessary mounting arrangement and making electric connection using three core flexible twisted copper conductor of size 23/0.0076" complete including taking down existing unserviceable fan and depositing to MES store all as specified and directed. [Make: Havells/ Orient/ Bajaj/ Usha].
44S&F PVC extension junction box with combined switch and socket,6A, 6 module, 3/5 Pin socket 230V for multiple electrical appliances along with connection of twin core PVC cable of 1.5 Sq.mm up to a length of 5 Mtr complete as required and as directed. [Make: Anchor/ Cona/ GM/ Leader]
45S&F PVC extension junction box with combined switch and socket,16A, 4 module, 3/5 Pin socket 230V for multiple electrical appliances along with connection of twin core PVC cable of 2.5 Sq.mm up to a length of 5 Mtr complete as required and as directed. [Make: Anchor/ Cona/ GM/ Leader]
46S&F in repairs Surface PVC box 4 Module of size 85x145x42mm all side covered complete all as specified and as directed. [Make: Anchor/ Cona/ GM/ Leader]
47S&F in repairs Surface PVC box 6 Module of size 85x219x42mm all side covered complete all as specified and as directed. [Make: Anchor/ Cona/ GM/ Leader]
48S&F in repairs Surface PVC box 2 Module of size 85x85x40mm all side covered complete all as specified and as directed. [Make: Anchor/ Cona/ GM/ Leader]
49S&F in repairs rigid non metallic concealed PVC conduit ISI marked of size 20mm dia inclusive of all tees, bends, elbow, reducers, bell mouth tube ends and fixing accessories such as couplers. locknuts, saddles, pipe hook etc. over the surface/recess complete all as specified and directed.
50S&F in repairs rigid non metallic PVC casing and capping, ISI marked of size 20x12mm inclusive of all fixing accessories and casing pin etc. over the surface complete all as specified and directed.
51Taking down carefully electric geyser storage type of any capacity, after disconnecting all electrical and water connections, from its position, opening of geyser tank after removing glass wool and taking out copper inner tank for rectifying the leakage by necessary welding, brazing, soldering, replacement of worn out nut-bolts, washer as required and reassembling & re-fixing the same after making it functional at its position including necessary testing complete all as specified and directed. NOTE: - The cost of welding / soldering material, nut-bolts, washers as required and transportation charges shall be deemed to be included in the unit rate. T&P as required shall be provided by the contractor and cost thereof deemed to be included in the quoted rate.
52S&F as in replacement, brass water inlet and outlet assembly along with rubber gasket suitable for 25 Litres capacity electric geyser including provision of housing thermostat assembly, heating element fixing arrangement, nut-bolts and washers as required complete all as specified and directed. [Make: Bajaj/ Racold/ Ditz/ Shakti].
53All as per Item No. 55 herein before but for Geyser of 50 Ltr capacity
54S&F as in replacement, thermostat switch suitable for electric geyser of any capacity as per sample complete all as specified and as directed. [Make: Bajaj/ Racold/ Ditz/ Shakti].
55S&F as in replacement, heating element triangular type of capacity 1.50 KW complete all as specified and as directed. [Make: Daspass, Theeta, Airex].
56S&F as in replacement, heating element round type of capacity 1.50 KW complete all as specified and as directed. [Make: Daspass, Theeta, Airex].
57S&F as in replacement, heating element triangular type of capacity 2 KW complete all as specified and as directed. [Make: Daspass, Theeta, Airex].
58S&F as in replacement, heating element round type of capacity 2 KW complete all as specified and as directed. [Make: Daspass, Theeta, Airex].
59S&F as in replacement, pressure release valve 0.70 mpa, conforming to relevant IS, 15mm size suitable to fix with 15mm bore GI pipe complete all as specified and as directed. [Make: Pearl/ Airex/ Racold]
60S&F as in replacement, 450 mm long heavy duty hot & cold PVC connection with CP brass connectors at both ends suitable for 15 mm bore water supply line complete all as specified and as directed. [Make: Prayag/ Netco/ Getco].
61S&F as in replacement, indicating lamp single pole, AC 230 volts, round or rectangular shaped as required, suitable for electric geyser of any capacity complete all as specified and directed.
62S&F MCB SPN, 240 volts, 40 to 63 Amps, "C" curve, 10 KA all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB]
63S&F MCB SP, 240 volts, 6 to 32 Amps, "C" curve, 10 KA all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB]
64S&F sheet steel powder coated distribution board 2 ways, 240 volts, with 200 Amps rated bus bar, neutral link, earth bar, suitable for mounting MCBs all as specified and as directed including taking down existing unserviceable DB all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB]
65S&F in replacement, thermal cut out Bimetallic disc type along with snap action switch, with operator below the boiling point i.e. 90°+6°C with manual reset knob for Geyser complete all as specified and as directed. [Make: Bajaj/ Racold/ Ditz/ Shakti/ Airex].
66S&F in replacement, metal plug top 15 Amp rating with 3 pins, 230 volts complete all as specified and directed. [Make: Legrand/ Havells/ Anchor/ GM/ L&T]
67S&F in replacement, PVC plug top 15 Amp capacity with 3 pins, 230 volts complete all as specified and directed. [Make: Anchor/ Cona/ GM/ Leader]
68S&F in replacement, work shop cable, copper Flexible 3 core of size 40/0.0076" complete all as specified and as directed.
69S&F in replacement, work shop cable, copper Flexible 3 core of size 70/0.0076" complete all as specified and as directed.
70S&F in replacement, Multi function safety valve along with necessary fixing arrangement suitable for Geyser of 25 Litres capacity complete all as specified and directed. [Make: Pearl/ Airex/ Racold]
71S&F in replacement, fusible plug complete all as specified and directed. [Make: Pearl/ Airex/ Racold]
72S&F in replacement, clamps along with suitable size of nut-bolts and washers (150mm Long) complete all as specified and directed.
73S&F in replacement, half door set suitable for 25 Litres capacity Geyser complete all as specified and directed. [Make: Pearl/ Airex/ Racold]
74S&F in replacement, rubber gasket heavy duty suitable for 25 Litres capacity Geyser complete all as specified and directed. [Make: Pearl/ Airex/ Racold]
75S&F in replacement, mounting plate suitable for 25 Litres capacity Geyser complete all as specified and directed. [Make: Pearl/ Airex/ Racold]
76S&F glass wool suitable for water storage geyser of any capacity complete all as specified and directed.
77M&L for sub main wiring concealed complete with two runs of 1100 Volts grade 4 sq.mm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade drawn through and including 20mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls/ roofs/ floors etc. with one run of 1100 Volts grade 4 sq.mm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade as earth continuity conductor all as specified. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
78M&L for sub main wiring concealed complete with two runs of 1100 Volts grade 6 sq.mm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade drawn through and including 20mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls/ roofs/ floors etc. with one run of 1100 Volts grade 6 sq.mm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade as earth continuity conductor all as specified. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
79M&L for sub main wiring concealed complete with two runs of 1100 Volts grade 2.5 sq.mm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade drawn through and including 20mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls/ roofs/ floors etc. with one run of 1100 Volts grade 2.5 sq.mm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade as earth continuity conductor all as specified. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
80S&F as in replacement ofElement 3 KW capacity suitable for Solar water heater of Capacity 200 to 300 Litres complete all as specified and directed.
81S&F sheet steel powder coated distribution board SPN 4 ways, 240 volts, with 200 Amps rated bus bar, neutral link, earth bar, double door with IP 43 protection, suitable for mounting MCBs all as specified and as directed including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB]
82Cutting existing GI pipe of size 20/25/40mm bore in position for insertion of new tees, branches etc including connection complete all as specified and as directed.
83S&F in repairs 20mm dia stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for unions/sockets and fixed complete all as specified and as directed.
84S&F in repairs 15mm dia bib cock, cast copper alloy, screwed down high pressure, with crutch or butterfly handle screwed both ends for unions/sockets complete all as specified and as directed.
85S&F in repairs GI pipe of 15mm dia medium grade including all fittings fixing to wall/floor or laying in trenches complete all as specified and directed.
86Supply, fixing, Installation and testing of storage type water heater (Geyser) 25 Ltrs capacity, BEE 5 star rated with glass lined inner tank & powder coated steel outer bodyincluding pressure valve & electric supply connection complete including grouting with nuts & bolts of 15mm dia 100mm long for hanging the geysers, including PVC connection 15mm dia, 450mm long heavy duty suitable for hot & cold water connections complete including plastering and finishing of disturbed wall surface as per existing finish complete all as specified and as directed including taking down existing unserviceable geyser and handing over to MES store.. [Model: HSE-VAS-X of make: AO Smith or equivalent in Racold/ Venus]
87S&F in repairs LED String Light strip, decorative, multi colour with different modes, minimum 20 m long, 230 voltsalong with suitable type LED driver complete all as specified and as directed.
88Deduct: Amount of Schedule of Credit b/f from Sl. Page No. 17 of tender document i.e. Rs. 1,09,435.00
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail