Tender For Replacement/ Augmentation Of Old/Frayed Condcutor Of 11 Kv, Replacement Of Old/Frayed Lt Conductor (Lt Bare To Lt Bare And Lt Bare To Lt Ab Cable) And Capacitor Banks Under Revamped Reforms-Based And Results-Linked, Distribution Sector Sch
Tender Overview
Project Description
Replacement / Augmentation Of Old / Frayed Condcutor Of 11 Kv, Replacement Of Old / Frayed Lt Conductor ( Lt Bare To Lt Bare And Lt Bare To Lt Ab Cable ) And Capacitor Banks Under Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme
BOQ
| Sl. No. | Item Description |
| 1 | 11 KV Feeder Replacement with DOG Conductor |
| 2 | 11.0 Mtr. Long Steel Lattice Structure with (65 x 65 x 6 mm) M.S. angle suitable for ACSR DOG Conductor including all nuts & bolts complete without arms. |
| 3 | 11 kV Disc Insulator 70 KN, B&S / TC Type |
| 4 | Hardware Fittings for disc insulator suitable for DOG conductor |
| 5 | 11 KV Pin Insulator (Porcelain) with G.I Pin & fittings as required ( ABI / Saravanan or equivalent ) |
| 6 | DOG Conductor 100 sqm, 6/4.72+7/1.57 |
| 7 | G.I. Wire 4 mm (8-SWG) for Continuous Earth |
| 8 | PG Clamp for Dog Conductor |
| 9 | Compression Joint for ACSR Dog conductor |
| 10 | Back clamps of 75x8mm M.S. flat for holdingchannel. |
| 11 | M.S. nuts & bolts of 16mm dia.X 40mm length. |
| 12 | M.S. channel 75X 40X 6mm 1.8 m long for S.P.structure. |
| 13 | Pole top channel 75X40X 6mmX0.3m long S.P. structure. |
| 14 | Structure Earthing: 25x3 mm G.I. Flat with perforated G.I. pipe of 19mm dia x 95 cm. and 38 mm dia x 250 cm combination with Reducer, Funnel and Cover Arrangement as per design to be provided and Salt (80 Kgs) & Charcoal (3 bags) Combination etc. |
| 15 | Guy Assembly complete with 7/10 SWG Stay Wire, 140x85 mm H.T Guy Insulator, 18mm diameter Stay Rod 1.8 mtrs Long with bow thimble, turn buckle & 300x300x6mm anchor plate |
| 16 | Red oxide paint @ 2 ltr/ pole |
| 17 | Aluminium paint @ 1.5 ltr / pole |
| 18 | G.I. Barbed Wire |
| 19 | 11 kV Caution Board |
| 20 | G.I. Wire 4 mm (8-SWG) for Continuous Earth |
| 21 | 11 KV Feeder Replacement with RABBIT Conductor |
| 22 | 11.0 Mtr. Long Steel Lattice Structure with (65 x 65 x 6 mm) M.S. angle suitable for ACSR Rabbit Conductor including all nuts & bolts complete without arms. |
| 23 | 11 kV Disc Insulator 70 KN, B&S / TC Type |
| 24 | Hardware Fittings for disc insulator suitable forRabbit conductor |
| 25 | 11 KV Pin Insulator (Porcelain) with G.I Pin & fittings as required ( ABI / Saravanan or equivalent ) |
| 26 | Rabbit Conductor 50 sqm |
| 27 | G.I. Wire 4 mm (8-SWG) for Continuous Earth |
| 28 | PG Clamp for Rabbit Conductor |
| 29 | Compression Joint for ACSR Rabbit conductor |
| 30 | Back clamps of 75x8mm M.S. flat for holdingchannel. |
| 31 | M.S. nuts & bolts of 16mm dia.X 40mm length. |
| 32 | M.S. channel 75X 40X 6mm 1.8 m long for S.P.structure. |
| 33 | Pole top channel 75X40X 6mmX0.3m long S.P. structure. |
| 34 | Structure Earthing: 25x3 mm G.I. Flat with perforated G.I. pipe of 19mm dia x 95 cm. and 38 mm dia x 250 cm combination with Reducer, Funnel and Cover Arrangement as per design to be provided and Salt (80 Kgs) & Charcoal (3 bags) Combination etc. |
| 35 | Guy Assembly complete with 7/10 SWG Stay Wire, 140x85 mm H.T Guy Insulator, 18mm diameter Stay Rod 1.8 mtrs Long with bow thimble, turn buckle & 300x300x6mm anchor plate |
| 36 | Red oxide paint @ 2 ltr/ pole |
| 37 | Aluminium paint @ 1.5 ltr / pole |
| 38 | G.I. Barbed Wire |
| 39 | 11 kV Caution Board |
| 40 | G.I. Wire 4 mm (8-SWG) for Continuous Earth |
| 41 | LT BARE TO LT ABC(3X95+1X50+1X16)SQMM |
| 42 | 8.5 Mtr STP complete with nuts & bolts-410 SP21 |
| 43 | Tension Clamp for Dead End for L.T A B Cable |
| 44 | Suspension Clamp for L.T A B Cable |
| 45 | Tension Clamp for Dead End with Attachment |
| 46 | Clamps for Neutral |
| 47 | Piercing Connector TYPE -I, 1P/3P (Main 16-50 sqmm Tap Off 16-50 Sqmm) |
| 48 | Piercing Connector TYPE -II, 1P/3P (Main 16-50 sqmm Tap Off 16-50 Sqmm) |
| 49 | LTAir Bunched Cable 3 x 95 Sqmm + 1 x 50 Sqmm insulated neutral cum Messenger + 1 x 16 sqmm, 1.1 KV |
| 50 | Stay set including 16 mm Dia x 1.8 mtr Long Rod, and 110 x 75 x 6 mm Anchor Plate complete with 7/12 SWG Stay Wire |
| 51 | Back Clamps 75 x 8 mm flat |
| 52 | Earthing Coil of 115 Turns of 50 MM Dia and 2.5 Mtr Lead of 4.0 mm G.I Wire |
| 53 | Spring Loaded Busbar System suitable for 1 Incoming 3 Outgoing 3 Phase Circuit |
| 54 | Spring Loaded Busbar System suitable for 1 Incoming 6 Outgoing 1 Phase Circuit |
| 55 | Red Oxide Paint |
| 56 | Aluminium Paint |
| 57 | Anti Climbing Device (Barbed Wire) |
| 58 | 440 Volt Caution Board |
| 59 | LT BARE TO LT ABC(3X70+1X50+1X16)SQMM |
| 60 | 8.5 Mtr STP complete with nuts & bolts-410 SP21 |
| 61 | Tension Clamp for Dead End for L.T A B Cable |
| 62 | Suspension Clamp for L.T A B Cable |
| 63 | Tension Clamp for Dead End with Attachment |
| 64 | Clamps for Neutral |
| 65 | Piercing Connector TYPE -I, 1P/3P (Main 16-50 sqmm Tap Off 16-50 Sqmm) |
| 66 | Piercing Connector TYPE -II, 1P/3P (Main 16-50 sqmm Tap Off 16-50 Sqmm) |
| 67 | LTAir Bunched Cable 3 x 70 Sqmm + 1 x 50 Sqmm insulated neutral cum Messenger + 1 x 16 sqmm, 1.1 KV |
| 68 | Stay set including 16 mm Dia x 1.8 mtr Long Rod, and 110 x 75 x 6 mm Anchor Plate complete with 7/12 SWG Stay Wire |
| 69 | Back Clamps 75 x 8 mm flat |
| 70 | Earthing Coil of 115 Turns of 50 MM Dia and 2.5 Mtr Lead of 4.0 mm G.I Wire |
| 71 | Spring Loaded Busbar System suitable for 1 Incoming 3 Outgoing 3 Phase Circuit |
| 72 | Spring Loaded Busbar System suitable for 1 Incoming 6 Outgoing 1 Phase Circuit |
| 73 | Red Oxide Paint |
| 74 | Aluminium Paint |
| 75 | Anti Climbing Device (Barbed Wire) |
| 76 | 440 Volt Caution Board |
| 77 | LT BARE TO LT ABC(3X50+1X35+1X16)SQMM |
| 78 | 8.5 Mtr STP complete with nuts & bolts-410 SP21 |
| 79 | Tension Clamp for Dead End for L.T A B Cable |
| 80 | Suspension Clamp for L.T A B Cable |
| 81 | Tension Clamp for Dead End with Attachment |
| 82 | Clamps for Neutral |
| 83 | Piercing Connector TYPE -I, 1P/3P (Main 16-50 sqmm Tap Off 16-50 Sqmm) |
| 84 | Piercing Connector TYPE -II, 1P/3P (Main 16-50 sqmm Tap Off 16-50 Sqmm) |
| 85 | LTAir Bunched Cable 3 x 50 Sqmm + 1 x 35 Sqmm insulated neutral cum Messenger + 1 x 16 sqmm, 1.1 KV |
| 86 | Stay set including 16 mm Dia x 1.8 mtr Long Rod, and 110 x 75 x 6 mm Anchor Plate complete with 7/12 SWG Stay Wire |
| 87 | Back Clamps 75 x 8 mm flat |
| 88 | Earthing Coil of 115 Turns of 50 MM Dia and 2.5 Mtr Lead of 4.0 mm G.I Wire |
| 89 | Spring Loaded Busbar System suitable for 1 Incoming 3 Outgoing 3 Phase Circuit |
| 90 | Spring Loaded Busbar System suitable for 1 Incoming 6 Outgoing 1 Phase Circuit |
| 91 | Red Oxide Paint |
| 92 | Aluminium Paint |
| 93 | Anti Climbing Device (Barbed Wire) |
| 94 | 440 Volt Caution Board |
| 95 | CAPACITOR BANK |
| 96 | 12.65 kV, 2000 KVAr, 3-Phase, 50 Hz, Outdoor Type, Capacitor bank havingstep as 900 Kvar + 900 Kvar + 200 Kvarat 12.65 KV. Bank shall be complete with Capacitor control panel of 100/200/400 kVAr at7.3 KV, including Capacitors, Reactors, Vacuum Capacitor Switches allied material such as suitable size of Aluminium busbars, Pin/Post insulators, Expulsion fuses, 3-Phase Oil-Cooled RVT,L.A,Isolator & Structure for complete Equipment etc. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender