Tender For Provision Of 140 Kva Generator Set And 62.5 Kva Sound Proof Silent Dg Set With Amf Panel At Mintsd Under Under Ge (South) Pune, pune-Maharashtra

Military Engineer Services-MES has published Tender For Provision Of 140 Kva Generator Set And 62.5 Kva Sound Proof Silent Dg Set With Amf Panel At Mintsd Under Under Ge (South) Pune. Submission Date for this Tender is 25-07-2023. Diesel Generators Tenders in pune Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

37939704
Corrigendum : Tender For Provision Of 140 Kva Generator Set And 62.5 Kva Sound Proof Silent Dg Set With Amf Panel At Mintsd Under Under Ge (South) Pune
Open Tender
Indian
Maharashtra
pune
25-07-2023

Tender Details

Provision Of 140 Kva Generator Set And 62.5 Kva Sound Proof Silent Dg Set With Amf Panel At Mintsd Under Under Ge ( South ) Pune

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Jun-2023 Corrigendum No 1 dt 06 Jun 2023 Date 21-06-2023
2 13-Jun-2023 Corrigendum No 2 dt 13 Jun 2023 (Change in dates) Date 26-06-2023
3 17-Jun-2023 Corrigendum No 3 dt 17 Jun 2023 (Change in dates) Date 30-06-2023
4 22-Jun-2023 Corrigendum No 4 dt 22 Jun 2023 (Change in dates) Date 04-07-2023
5 24-Jun-2023 Corrigendum No 05 dt 24 Jun 2023 (Change in dates) Date 10-07-2023
6 01-Jul-2023 Corrigendum No 06 dt 01 Jul 2023 (Change in dates) Date 15-07-2023
7 07-Jul-2023 Corrigendum No 7 Change in Date Date 18-07-2023
8 07-Jul-2023 85868 Corrigendum for BOQ BOQ 18-07-2023
9 18-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 55920.0 /-
Tender Value
INR 27.96 Lakhs /-

BOQ Items

Name of Work : PROVISION OF 140 KVA GENERATOR SET AND 62.5 KVA SOUND PROOF SILENT DG SET WITH AMF PANEL AT MINTSD UNDER UNDER GE (SOUTH) PUNE
Sl. No. Item Description
1Supply,install,testing and commissioning of silent Diesel Engine driven generating set of capacity 62.5KVA, 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with and including concrete foundation and plinth (as per OEM design), control panel with necessary meter and sound proof canopy as per CPCB-II norms including all tools and spears complete all as specified and directed and comprising of the following :-
2a) Engine : Diesel engine, 4cylinder engine developing required 84 BHP @ 1500 RPM for continuous duty suitablefor62.5 KVA alternatorwith provision of 10% over load for one hour in every 12 hour running confirming to BS 5514/ISO 3046 and revised editions as applicable standard Totally enclosed,electric star,compression ignition,4 stroke.The engineshall consists of following specification:-
3(i) Fly wheel to suit flexible coupling with starter ring, cooling radiator with blower fan, fuel hoses, mico fuel pump with mechanical governor, oil bath type air cleaner, exhaust silencer, SS expansion bellow, lubricating oil filter, fuel oil filter, 24 V electric starting system, battery charging alternator, engine control panel consisting of ON/OFF START key, lub oil pressure guage, water temp guage, ammeter battery chargingsafely divices such as:low lubricating oil pressure, light water temperature ect as per standard norms.
4(ii)   Instrument panel consisting of: Starting switch with key lubricating oil, temperature guage, lubricating oil pressure gauge,water temperature guage, battery charging indicatinglamp, hour meter with RPM indicator, safety control against high temperature of water, over speed stop with double driver adopter complete.
5(iii) Alternator : Self excited self regulated, floor mounted with all and / or roller bearings, statically and dynamically balanced screen protected SPDP enclosures confirming to IS 4722 / BS 2613, single shaft extensive type with damper with damper winding on pole ‘F’ class insulation automatic voltage regulated from no load to full load, ammeter capacity of delivery 62.5 KVA,415 volts, 3 phase, 50cycles andlagging for AC supply and will be suitable for tropical conditions.
6(b) OTHER FITTINGS : (i) Battery Charger : Battery charger having electric circuit consisting of rectifiers, capacitors and resistance etc. The battery charger should be able to charge 12 volts 180 AH battery 2 Nos at a time (ii) Fuel tank of suitable capacity as per manufacturer recommendation mounted on steel frame at suitable height with all connecting pipes and fittings upto fuel pump and over flow pipe from engine to tank including level indicating gauge duly marked and drain valve and air vent plug etc. (iii) Maintenance Spares: (iv) Lub Oil filter elements - 05 Nos (v) Fuel filter element - 05 Nos (iii)Vee Belt set- 02 Sets (vi) Air cleaner element - 01 Set (v) Flexible coupling for Gen set - 01 No.(vii)Anti Vibration Pads for DGBase plate all as specified and directed.
7(c)DG set shall be supplied along with acoustic original enclosure of the manufacture’s suitable for 62.5 KVA DG Set as per CPCB Norms
8(d) The DIESEL OIL, LUB OIL etc. for smooth functioning of DG SET during PH-I& PH-II complete testing and full tank filling of DIESEL OIL after PH-I & PH-II testing, topping of LUB OIL etc. required for commissioning and testing of DG set.
9(e) Standby fuel tankof capacity 200 Litre made out of MS Sheet 2mm thickincl inlet, outlet, & connection with MS Pipe 15mm stop cock,mounted on heavy duty angle iron stand duly painted with one coat of red oxide primer and two two coats of synthetic enamel paint all as specified and directed.
10Supply, laying, jointing, testing and commissioning LT cable 95 Sqmm 3.5 Core, 1100 volts grade, XLPE insulated armoured and PVC sheathed with stranded aluminium conductor heavy duty, conforming to IS 1554 Part I, ISI marked,with and including cable glands, cable lugs etc to suit cable size, laid in trenches, fixed along the polesor through G.I. Pipe laid under floors road etc complete all as specified and directed
11Supply, install, testing and commissioning ofSilent Diesel Engine Generaing Set, 112 KW/140 KVA,1500 RPM, 3 phase,415 V, 50 c/s, power supply alternator along with fuel tank, control panel, battery and complete set installed in sound acoustic enclosure and standard accessories and fittings,with power factor 0.8, including concrete foundation and plinth suitable for the generator set as per manufacturer"s instructions, tools and spares complete all as specified and directed and comprising of the following:-
12a) Engine : Diesel engine, 6 cylinder engine developing required 184 BHP @ 1500 RPM for continuous duty of suitablefor140 KVA alternatorwith provision of 10% over load for one hour in every 12 hour running confirming to BS 5514/ISO 3046 and revised editions as applicable standard Totally enclosed, electric star, compression ignition, 4 stroke.The engineshall consists of following specification:-
13(i) Fly wheel to suit flexible coupling with starter ring, cooling radiator with blower fan, fuel hoses, mico fuel pump with mechanical governor, oil bath type air cleaner, exhaust silencer, SS expansion bellow, lubricating oil filter, fuel oil filter,24 V electric starting system,battery charging alternator,engine control panel consisting of ON/OFF START key, lub oil pressure guage, water temp guage, ammeter battery chargingsafely divices such as:low lubricating oil pressure, light water temperature ect as per standards norms.
14(ii)   Instrument panel consisting of: Starting switch with key lubricating oil, temperature guage, lubricating oil pressure gauge, water temperature guage, battery charging indicatinglamp, hour meter with RPM indicator, safety control against high temperature of water, over speed stop with double driver adopter.
15(iii) Alternator: Self excited self regulated, floor mounted with all and / or roller bearings, statically and dynamically balanced screen protected SPDP enclosures confirming to IS 4722 / BS 2613, single shaft extensive type with damper with damper winding on pole ‘F’ class insulation automatic voltage regulated from no load to full load, ammeter capacity of delivery 112KW/140 KVA, 415 volts, 3 phase, 50cycles andlagging for AC supply and will be suitable for tropical conditions.
16(b) OTHER FITTINGS : (i) Battery Charger : Battery charger having electric circuit consisting of rectifiers, capacitors and resistance etc. The battery charger should be able to charge 12 volts 180 AH battery 2 Nos at a time (ii) Fuel tank of suitable capacity as per manufacturer recommendation mounted on steel frame at suitable height with all connecting pipes and fittings upto fuel pump and over flow pipe from engine to tank including level indicating gauge duly marked and drain valve and air vent plug etc. (iii) Maintenance Spares: (iv) Lub Oil filter elements - 05 Nos (v) Fuel filter element - 05 Nos (iii)Vee Belt set- 02 Sets (vi)Air cleaner element - 01 Set (v) Flexible coupling for Gen set - 01 No
17(c) DG set shall be supplied along with acoustic original enclosure of the manufacture’s suitable for 140 KVA DG Set as per CPCB Norms
18(d) The DIESEL OIL, LUB OIL etc. for smooth functioning of DG SET during PH-I& PH-II complete testing and full tank filling of DIESEL OIL after PH-I & PH-II testing, topping of LUB OIL etc. required for commissioning and testing of DG set.
19(e)Excavation,earthwork and provn of PCC plinth of suitable sizes as per manufacturers instructions for installation of DG set & connected accessories complete.
20(f) Standby fuel tankof capacity 500 Litre made out of MS Sheet 2mm thickmounted on angle iron stand duly painted with one coat of red oxide primer and two two coats of synthetic enamel paint all as specified and directed.
21M&L for earthing complete with galvanised "steel earth plate electrode 600 x 600.× 6mm thick, buried "directly in ground (earth pit not less "than 2.25 metres deep below normalground "level) with top edge of the plate not "less"than 1.5 metres below normal "ground level, connected to "galvanisediron strip 32x6mm by means of bolts, nuts, check "nuts and washers of galvanised iron "or steel . earth strip protected by provision of GI medium grade pipe 50mm dia including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick RCC cover in CC 1:2:4 type B1 reinforced with XPM (weight not less than 4 kg/sqm) and frame made outin MS angle iron of size25x25x3mm with lugs02 Nos and withMShandle made in 6mm dia round bar made to shape, including GI medium grade 20mm bore pipe for watering, perforated at bottom1.75m long placed on top edge of earth plate including including provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate, test point made out of ohosphorus bronze with fixing arrangement ,funnel, wire mesh and earth work in hard/dense soil returning filling in and removal of surplus soil to a distance not exceeding 50mtr all as shown in electrical plate No. 3 of SSR Part I 2009connected to earthing test "point all as specified or indicated "including testing on completion.NOTE:-GI strip and GI pipe 40mm bore medium grade for encasing GI strip beyond 7.50m lengthper earthing if so required at site shall be measured and paid separately under relevant items.
22Supply, laying, jointing, testing and commissioningelectric power cable (heavy duty)of size 240 sqmm 3 .5 core, 1100 V grade with stranded aluminium conductor, XLPE insulated screened PVC bedded galvanised steel strip or wire armoured etc complete all as specified and directed.
23Supply, laying, jointing, testing and commissioning cable of size 120 sqmm 3 .5 core, 1100 V grade, XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor etc complete all as specified and directed
24Excavating in trenches n exc 1.5m wide & n exc 1.5m in depth; for foundation, etc. or for manholes etc n.exc.10 Sqm on plan and n.exc.1.5m in depth and getting out in soft/ loose soil complete all as specified. complete all as specified and directed
25Returning filling in, including spreading, levelling, watering and well ramming in layers n.exc. 25cm in soil complete all as specified and as directed
26Removing of excavated soil to a distancen exc. 50 m anddeposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
27Supply installation, commission and testingof outdoor typeFeeder pillar box Outdoortype,compartmentalised made out of CRCA sheet 3.15mm thick (width of panel shall not be less than 60 cm in any respect ) with powder coated painting and four Nos 500 amps Aluminiumstrip/bars ( not less than 65 mmx10 mm duly insulated mounted on insulators /suitable size backelite sheet ) mounted on angle iron frame of made out of 40mmx6mm angle ironand comprising the following .
28(a)MCCB4pole 315 Amp,415 volt ,16 KA,with thermal magnetic protection(overload &short circuit protection)-1No .(main incoming)
29(b) ditto butoutgoing MCCB ,4 pole, 100A, 16KA 415 V Ics = 100 % Icu =04 no
30(c)-do- butoutgoing MCCB 4 pole, 63A,16KA,Ics = 100 % =04 Nos
31(d)-do- butoutgoing MCCB 4 pole,16KAIcs = 100 % Icu with thermal release range range 100A=01 N0( standby)
32(e)DigitalVoltmeter range 0 to 500 voltsize 96 x96 sq mmwith selector switch-1No
33(f)   DigitalAmmeter range 0 to 100 Amp size 96 x96 sq mm =01 with selector switch and CT"S- 03Nos
34(g)LEDphase indicating lamps(red,yellow,Blue)=01 SET
35(h) On Load change over switch 200A,4Pole ,415V interconected to two main supply and DG supply all as specified and directed
36(Note : - The LT panel should be designed so as to accommodate 10% extra spacefor future expansion.)
37M&L for laying ofReinforced concrete pipes,class NP2 with one collar per lengh of pipe of dia 100 mm ,2 nos half round ( for bottom and top )and before laying exacaved area shall be leveling all as specified and directed Engr-in-charge.
38M&L forgalvanised tubing 100 mm light grade with all fittings laid in trenches all as directed by engineer in charge.
39M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortor 1:6 complete all as specified and as directed by Engr-in-Charge.
40M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 complete all as specified and as directed by Engr-in-Charge.
41M&L for hardcore of gauge exc 63 mm but n.exc 100 mm deposited, spread and leveled in layers n.exc 15 cm thick, watered and rolled/rammed to a true surfaces in broken stone or boulder complete all as specified and as directed by Engr-in-Charge.
42M&L 100 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone agg as in sub base complete all as specified and as directed by Engr-in-Charge.
43M&L 100 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone agg as in floor finished even and smooth complete all as specified and as directed by Engr-in-Charge.