Tender For Spl Repair Replacement Of Ber Pressure Filter And Capacitor Bank Of Water Supply Instln Provn Of 02 Water Cooler Each At Bldg No P397 And Ch Of Fd Hosp 02 Ac Split With Necessary Elect Fitting In Instrument Shop And Fuel Injection Eqpt Roo
Tender Overview
Project Description
Spl Repair / Replacement Of Ber Pressure Filter & Capacitor Bank Of Water Supply Instln, Provn Of 02 X Water Cooler Each At Bldg No P-397 And Ch Of Fd Hosp, 02 X Ac ( Split ) With Necessary Elect Fitting In Instrument Shop & Fuel Injection Eqpt Room Of Eme Bn, 02 X Tower Ac For Soi, 02 X Ac For Med Store & Opg Machine Room Incdu, 15 X Geyser Of ( Ta ) Garh Rif And Airfield Beacon At R&O Flt At Rms
BOQ
| Sl. No. | Item Description |
| 1 | S&Finstallation and testing and commissioning of Split type inverter Air conditionerof capacity 1.5 ton rating 5 star with cordless remote operated on 230 Volt AC supply complete to wall with suitable bracket for indoor outdoor unit and connected with electric suply, testing on full load complete all as specified and directed. Make : Voltas/Blue star/Godrej/LG |
| 2 | Supply and ffixing Voltage stablizer for automatic operation single phase indoor type and designed for input variation between 90-300 volts with digital disply out put voltage stabliser at 230 Volts with energy of± 2.5 % and of capacity 4 KVA complete all as specified and directed. Make Microtech/Volina/V-guard/Voltas |
| 3 | Supply and install vertical pack type tower Air conditioner units indoor/outdoor complete with cordless remote control and with inbuilt air ioniser and Plasma filter for better indoor air quality with twin rotary compresser three phase units 415 volts 50 Hz of capacity 3 TR complete all as specified and directed.. Make : Voltas/blue star/LG |
| 4 | M&L for sub main wiring with four runs of6.00 Sq mm and one run of 6.00 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn throughand including PVC double locked Casing & caping including complete all as specified and as directed. NOTE:- Four runs of 6.00 Sq mm + one run of 6.00 Sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length .Make:- Finolex/Havells/RR KabelMake of caping/casing :- Prestoplast/Finolex/supreme |
| 5 | M&L for sub main wiring with two runs of4.00 Sq mm and one run of 4.00 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn throughand including PVC double locked Casing & caping including complete all as specified and as directed.NOTE:- two runs of 4.00 Sq mm + one run of 4.00 Sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length.Make:- Finolex/Havells/RR KabelMake of caping/casing :- Prestoplast/Finolex/supreme |
| 6 | All asper item No 5.00 here in above butTwo runs 6 sqmm + one run 6sqmm (earth wire) in 25mm dia conduit/Casing caping . |
| 7 | M&L for metal clad AC socket point single pole and neutralenclosure with a tow pin and earth plug and socket complete with one single pole MCB SP 20 Amps complete all as specified and as directed. |
| 8 | Supply and fixing for tripple pole and earth enclosure with a three pin and earth plug with socket complete with one tripple pole MCB 32 Amps complete all as specified and directed. |
| 9 | M&L for MCB Distribution board double door type SPN 2 way with 200 amps rated busbar, sheet steel, powder painted, withneutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed. |
| 10 | M&L for MCB Distribution board double door type SPN 4 way with 200 Amps rated bus bar, sheet steel, powder painted, withneutral link & earth bar etc. and fixing MCBs of various rating capacity MCB DBs complete all as specified and as directed. |
| 11 | M&L for MCB Distribution board double door type SPN 8 way, sheet steel, powder painted, withneutral link & earth bar etc. and fixing MCBs of various rating capacity MCB DBs complete all as specified and as directed. Make : Legrand/ABB/Siemens |
| 12 | M&L for TPN 40 Amps to 100 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB \"C\" series MCB complete all as specified and as directed. Make:- Legrand Cat No 408636 or equivalent in ABB/Siemens |
| 13 | Supply and fixing MCB SPN 32 Amp rating 240V, 10KA \"C\" curve miniature circuit Breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 14 | M&L for MCB SP 6-32 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB \"C\" seriescomplete all as specified and as directed.Make:- Legrand/ABB/Siemens |
| 15 | M&L point wiring with, two single core, 2.5 Sqmm (nominal area) size multistranded FRLSHcopper conductor cable and one single core 2.5 Sqmm (nominal area) size solid copper conductor cable using colour code as phase , Neutralandas Earth continuity conductor connected to common earth dolly, 1100 volts grade,PVC insulated, unsheathed cabledrawn throughand including PVC casing capping and PVC boards with all fittings and fixing materials for one 5 pin 15 Amps socket outlet point controlled by one way switch all as specified and directed.Make:- Finolex/Richa/RR KabelMake of caping/casing & PVC boxes :- Prestoplast/Finolex/supreme/Richa |
| 16 | M&L Switch socket combination flush type 3 pin 16 Amp complete all as specified and directed. Make :Anchor/Legrand/Havells |
| 17 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed. Make-Havells/Bajaj/Crompton |
| 18 | Supply and laying tubes Medium grade galvanised GI tubing with all fittings, fixed complete to walls/poles/laid in floors/trenchs/road crossing of size 15 mm dia bore including complete all as specified and as directed. Make: Jindal/Prakash surya/TATA |
| 19 | Supply and laying tubes Medium grade galvanised GI tubing with all fittings, fixed complete to walls/poles/laid in floors/trenchs/road crossing of size 20mm dia bore including complete all as specified and as directed. Make: Jindal/Prakash surya/TATA |
| 20 | All as per Item No 19.00 but 25 mm bore GI tubing including complete all as specified and as directed. Make: Jindal/Prakash surya/TATA |
| 21 | S&F Stop valves, cast copper alloy, fancy type, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.: Make : Jindal/Prakash surya/TATA |
| 22 | S&F15mm boreBib tap fancy type chromium plated with long shank all as per specified and as directedMake: Jindal/Prakash surya/TATA |
| 23 | Supply and fixing Airfield rotating beacon light L-802A for night operation as identification and location markers, clear vision of 40 miles, lamp lifetime 4000 hrs, 10-18 rpm, IP-67 , 2150W 110/230V, 50/60HZ as per ICAO standard all as specified and as directed.Note : Pre-dispatch factory inspection to be carried out as per norms/ description and test report to be submitted along with invoice. |
| 24 | M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of16 sq mm, 2 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. |
| 25 | Excavation in trenches not exceeding 1.50 m wide and n.exc1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and as directed. |
| 26 | Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed . |
| 27 | Removing exvated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point completeall as specified and as directed . |
| 28 | Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cableincludingspreading and punning down to 23cm thickness complete all as specified and as directed. |
| 29 | Materials and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed. |
| 30 | M & L for galvanised steel tubing 40 mm bore light grade laid in trenches, road crossings pole/wall etc. for cable protection including providing MS flat iron 50mm x 6mm clamps (02 Nos) complete all as specified and directed including taking down the existing UNSV steel tubing complete all as specified and directed.. Make: Jindal/TATA/Nezone |
| 31 | Supply, installation, commis-sioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling 60/120 capacity as shown complete all as specified and directed.. Make : Voltas/Bule star |
| 32 | Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip 32x6mmby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. |
| 33 | Taking down old unserviceable (BER) water filtration plant, any size and capacity with and including connecting accessories and shifted to store yard of GE 868 EWS as per direction complete all as specified and directed. |
| 34 | Supply, install, testing and commissioning of complete set of multigrade sand filtration plant of 10000 GPH capacity with and including supplying of all equipments like face piping fittings, filter pump, filter media, valves, catalytic, Internal distribution system, pressure gauge, coagulant feeder with accessories, back washing facility etc including RCC foundation work as required as per manufacturer\"s specification, all complete plant to produce clear water free from suspended impurities and turbidity etc as per following specification:- (a)Shell Dimension 2500 mm dia x 1500 mm straight height.(b) Thickness of body, dish end & bed plate - 10 mm x 10 mm x 12 mm, frontal pipe line -100 mm ERW pipe (Medium), Valves in frontal pipe line - 100 mm butterfly valves, media (sand & Gravel) 185 cft, Oxidation chamber - Vertical, single deck, mild steel IS-2062, Shell 1000 mm dia x 1200 mm heightthickness of body, dish end & bed plate - 6 mm x 8 mm x 8 mm simultaneously, filter media (sand & Gravel) 185 cft, catalytic media (MnO2 compound)-47 Cft, pressure gauge -2 set for raw water and filter water and Oxidation chamber - Vertical, single deck, mild steel IS-2062 complete suitable for existing Air Compressor Model DH-9, Capacity 12 cfm,Chlorine dosing pump with FRP tank-RPQ 40 HD with CDS-100, Coagulation dosing - CI Alum pot and soda pot 14 litres with fittingscompleteall as specified and directed.Make : Sombansi Enviro Engg Pvt Ltd/ Thermax Ltd/ Sathya Sai Aqua Pura Services/Ion Exchange/Bharati Water. |
| 35 | Supply and fixing for 100 KVAR APFC Panel board will be floor mounted indoor type, free standing, dust and vermin proof, fabricated from 2mm CRCA Sheet, finished with powder coating paint & providing TPN 200A aluminum bus bar & wiring, consisting of the following feeders:-(a) 200A, TP, 36KA, MCCB-01 NOS(b) Spreader lin for 200A, TP, MCCB (Set of 6Pcs)-02 NOS(c) Extended rotary handle for 200A, TP, MCCB-02 NOS(d) Digital VAF (V,A,F) meter-02 NOS(e) LED Indicator lamp R,Y,B-06 NOS(f) CT 200/5A, Cl-1, Tape wounded-06 NOS(g) CT 200/5A, Cl-1, Tape wounded (For APFC) before load-02 NOS(h) 6A, SP, MCB-06 NOS(j) 8Th stage APFC Relay, 1CT Input-02 NOS(k) Auxiliary Contactor 2NO 2NC-04 NOS(l) Indicator lamp Red, Amber04 NOS(m) Auto manual selector switch-02 NOS(n) Cooling Fan 6\"-04 NOS(o) Thermostat-02 NOS(p) 6A, DP, MCB-02 NOS(q) 10A, DP, MCB-04 NOS |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender