| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: |
| 2 | All kinds of soil |
| 3 | Providing and laying of dry stone solling tightly hand picked on horizontal levels |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 5 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing with.1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 20mm nominal size) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:2:4 mix |
| 7 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. |
| 8 | Dry random rubble masonry with hard stone in foundation and plinth: With bond stone |
| 9 | Providind and Laying of Reinforced cement concrete work in walls (any thickness) including attached pilasters,buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering,finishing and reinforcement of mix 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 10 | Reinforced cement concrete work in arches, archribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcement with: 5.5.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 12 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 14 | Foundations, footings, bases of columns etc. for mass concrete. |
| 15 | Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 16 | Suspended floors, roofs, landings, balconies and access platforms |
| 17 | Columns, pillars, piers, abutments, posts and struts |
| 18 | 12mm Cement plaster of mix 1:4(1 cement : 4 fine sand) |
| 19 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) with floating coat in Septic tank. |
| 20 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above/upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 21 | Structural steel work in built up sections, trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat ofapproved steel primer all complete.Welded |
| 22 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 23 | Providing corrugated G. S. coloured sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 24 | Providing and fixing of stailness steel (Grade Ist) railing made of hollowtubes, channels, Plates etc including welding, Grinding, Buffing, polishing and making curvature (whereever required ) and fitting the same with necessary assessories and stailness steel fasteners stainless bolts etc of required size on the top of the floor are the side of waiste slab with suitable arrangement as per the direction of Engineer incharge |
| 25 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately)Second class kail wood. |
| 26 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately. First class kail wood |
| 27 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 28 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge :Second class Kail wood.35 mm thick |
| 29 | Fixing of chain link fencing of mesh size 50*50mm of 4mm G.I wire. |
| 30 | Applying priming coat:With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood |
| 31 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work. |
| 32 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.1 mm thick |
| 33 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm |
| 34 | Providing and fixing stainless steel A ISI 304 (18/8) kitchen sink as per I.S.13983 with C.I brackets and stainless steel plug 40mm. Including painting of fittings and brackets, cutting and making good the walls wherever required:610*510mm bowl depth 200mm |
| 35 | Providing & fixing water closet squatting pan(Indian type.W.C.pan)with 100mm sand cast Iron with “S” or “P” trap.10 liter low level white P.V.C flushing cistern,including flushpipe (of approved make)with manually controlled device (handle lever) conforming to IS:7231.with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. (Orissa pattern with integral foot type) |
| 36 | Flooring with marble stone of specified thickness as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed with grey cement slurry including rubbing, polishing and curing complete with: Makrana White Second quality |
| 37 | Providing Ist quality ceramic glazed tiles confirming to IS:13753 of minimum thickness 5mm of approved makelike NITCO ORIENT,SOMANY,KAJARIA or equivalent make in all colour , shades except burgundy, bottle green, black of any size as approved by Err in charge in skirting,risers of steps and dados over 12mm thick bed of cement mortar 1:3(1 cement, 3 coarse sand)and jointing with grey cement slurry @ 3.3 kgs/SM including pointing in white cement mixed with pigment of matching shade complete. |
| 38 | Providing and fixing of eves boarding coloured plain GI sheet 300mm wide.(18 guage) All complete as directed by Engineer Incharge at site. |
| 39 | Providing and fixing soffits of coloured sheets of 0.50mm thick including formation of base all complete as directed by Engineer Incharge at site. |
| 40 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 41 | Providing, hoisting and fixing, trusses,purlins, rafters,using ist class poplar wood.As directed by Engineer Incharge at site. |
| 42 | Providing and fixing of glass panes 4mm thick with wooden fillets. |
| 43 | Providing & laying of filter media effective size of sand varies from 0.45mm to 0.70mm having uniformity coefficient between 1.30 to 1.75 & should be dustfree & free from other organic impurities to be obtained from Ganderbal Nallah &the size of gravel should vary from 2mm to 40mm include all carriages complete. |
| 44 | Providing & Fixing of 150 mm dia DF sluice value with caps, nuts bolts,washers complete job (Kirlosker make) |
| 45 | Providing & Fixing of 300 mm dia DF sluice value with caps, nuts bolts,washers complete job (Kirlosker make) |
| 46 | Providingand fixing of 250mm DF sluice valves confirming IS 780 read with up to date amendments standard make (VAG) meat for pipe gallery in filter beds required from operating plateform height 3.5m. Hence suitable arrangement for manual operations to be provided the job includes providing and fixing and fabrication of MS 6mm thick tail pieces as per site requirement, nuts bolts and seals the sluice vaves be fitted with extension rods pedestal etc( Filter beds, inlet and outlet) |
| 47 | Providing and fixing of 80mm diameterPVC under drainage laterals 8mm thick fabricated out of Korean foam or prince make with 9mm perforations as per design in the bed provided at 60degree along with Pvctees and end caps to be grouted in M25 grade cement concrete at ends the pressure rating 10kg\"s/cm2 |
| 48 | Providing & fixing of MS Flanges of 12mm thickness including cutting of threaded portion,cost of nuts, bolts ,washers all complete for |
| 49 | 150 mm Dia |
| 50 | 100 mm Dia |
| 51 | Providing and fixing of air blower(Everest make or kay make) capable for providing compression @10.50 cum per minute @0.35kg/sqm with suitable 3 phase induction motor with auxiliary pipe system up to filter beds filling pressure guage nozzles cement concrete block base plate air check valve non return valve cement concrete block in M 20 grade foundation bolts base frame fabricated out of100mm MS channels the job also includes PRV pipe and pipe fittings starters and PVC19/18 copper wire complete job and other electrical controlling devices fitted on panel board. Complete job. |
| 52 | Providing installation testing commissioning of kirloskar make monoblock pumping equipment capable of lifiting of 50cum per hour for a height of 20m with 3 phase appropriate rating power induction mover with starter assembly suction and dlivery fittings up to back wash, the job includes all electrical operating devices fitted in panel board. |
| 53 | Providing and fixing of mechanical equipment required for Alum solution tank with electrically driven paddle assembly fitted with suitable reduction gear mechanism coupled with 3 phaseelectric motor 1HP capacity (Kirloskar/ crampton Greaves make) along with 40mm diameter PVC pipeand pipe fittings up to point of application in the flash mixer along with washout arrangement plus 25mm diameter GI inlet water line from back wash tankto alum tank with GI pipe specials and gate valves.(B-class pipe) include electrical operating devices complete job. |
| 54 | Providing and fixing of mechanical equipment required for bleach solution tank with electrically driven paddle assembly fitted with suitable reduction gear mechanism coupled with 3 phaseelectric motor 1HP capacity (Kirloskar/ crampton Greaves make) along with 40mm diameter PVC pipeand pipe fittings up to point of application in the clear water chamber along with washout arrangement plus 25mm diameter GI inlet water line from back wash tankto alum tank with GI pipe specials and gate valves.(B-class pipe) include electrical operating devices complete job. |
| 55 | Providing and fixing of MS rotating bridge fabricated out of ISA 50×50×6mm suitable for bearing silt load of clarifloculator (Floculator radius=5.1m). The job includes central bearing assembly shaft assembly MS wheels O-stop wheels,end carriages with adequate rating prime mover 3 phase 440 volts 50 HZ including fly wheel plus MS rail ISLC-100 on fish plate grounted on top base of clarifloculaterin cement concrete 6mm thick chequreds flooring over full span of bridge.the job includes providing and installation of 3 phase cubical electrical pannel having capacity of 63 Amp.with one incoming feeder and one outgoing feeder including of auxilary system fitted with appropriate rating 3 phase MCCB, OCB and MLI (L&T make)starters for operation of electrical motors and end carriage system.the job also includes connecting pole system and appropriate guage PVC copper wire. Complete job. |
| 56 | Providing installation testing commissioning of flash mixer assembly suitable for a diameter of 1.15m comprising of SS churners with vertical type hollow shaft prime mover 3 phase 450 RPM. The job includes constant bleed assembly with reduction gear box and operational gear to regulate the bleed. Complete job. |
| 57 | Providing instalation testing commissioningof 3 phase oil immersed 30 KVA voltage stabilizer (servo make) capable to operate incoming voltage of 180 volts and outgoing voltage of 410 + _10% volt. Complete job. |
| 58 | Providing and fixing of 50 sqm of 3.5 core aluminium armoured cable from HT transformer to MCCB inside filtration plant. |
| 59 | Providing installation testing commisionning of 4 pole 200 Amp (L&T make) MCCB fitted on wall mounted panel including thimbling complete job |
| 60 | Providing installation testing commissioning of 100 Amp dust /moisture proof cubical panel board fitted with 3 phase 100 Amp MCCB L&T make 02 No. and 63 Amp single phase MCCB for lighting system. The job also includes 1 No. amp mete 0-100 AE make with CT coils and one number voltmeter AE make 0-500 with selector switches L&T make and 3 No. indicator lamps Neon type complete job. |
| 61 | Providing and fixing of heating points in 4mm mm PVC copper wire for filter house and operator quarter |
| 62 | Providing and fixing of lighting points in 1.5mm PVC copper wire, LED conical type of Havlles/syska make of 8 watt include push buttons etc.Complete job. |
| 63 | Providing and fixing of philips make high mass security lights to be fitted inside filtration plant premesis with high mass GI poles. complete.The job includes circuit wire of required specifications and all fittings complete. |
| 64 | Providing and fixing of exhaust fan in the chemical house complete job(Havel\"s Ushas, crompton greaves make) for filtert house and operator quarter. |
| 65 | Providing and fixingof ceiling fans in the operating room of Havells/Usha,crompton make for filter house and operator quarter. |
| 66 | Providing necessary earthing for motor panels lightning and heating networks as per prevailing electric rules with latest amendments with necessary medium including refilling complete job (Electrode type).Complete job. |
| 67 | Laying in positon centrifugally cast (spun) iron S&S or flanged pipes (excluding cost of pipe) |
| 68 | Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket. |
| 69 | 300 mm dia D.I pipes |
| 70 | 250 mm dia D.I pipes |
| 71 | Dismantling cement concrete work of walls at spots and laying back of cement concrete in 1:1.5:3 mix including all carriages |
| 72 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 73 | Providing installation testing commissioning of double flanged MS pipes of 6mmthick and other allied accessories. The job includes cutting welding and fabrication complete job. |
| 74 | 150mm dia |
| 75 | 100/80mm dia |
| 76 | Supplying and laying of matting in two layers as per directions of Engineer Incharge. |
| 77 | Carriage of material from source to dumping site at road by mechanical transport. |
| 78 | Cement and steel for avg. lead of 15 Km |
| 79 | Sand for avg. lead of30Km |
| 80 | Aggregate for avg. lead of15Km |
| 81 | Bricks for average lead of15 Km |
| 82 | Stone solling For avg lead of 05 km |
| 83 | Carriage ofPipes material From divisinal storeto dumping site of work by mechanical transport For anaverage lead of 15 Km including loading , unloading and stacking complete . |
| 84 | 300mm dia DI pipes for average lead of 18 KM |
| 85 | 250mm dia DI pipes for average lead of 18 Km |
| 86 | Electric Sub-Station |
| 87 | P/I/T/Commissioning of 63 KVA 3 phase and neutral distribution transformer of following specifications and details:-A)Type:-Distribution transformer, naturally aspirated, oil cooledB) Capacity:-63 KVA ( C) Operating ConditionsD) Terminals E)Core:- High permeability core for heat dissipation, fabricated out of suitable size and gauge strips. F) Transformer Coils:- Suitable no. of HT& LT coils in each leg. The transformer coils shall be fabricated out of superior quality aluminium wire/ strips properly wound. G) Coolant:- The HT transformer shall be completely filledwith “A” grade transformer oil upto required level. H) Enclosure: - The core, coils, brackets shall be enclosed in MS tank of suitable thickness with cooling conduits /fins on either side. The MS tank shall be painted in to two coats of enamel synthetic paint and the tank shall be fitted with drain plug and oil level indicator. 1)Input:-11000Volts2 ) Output:-440 Volt AC supply, 3 phase 1)Input: - 3 No. HT bush rods with insulators, washers, nuts etc.2) Output:- 4 No. LT bush rods with insulators, washers, nuts etcBesides above the whole assembly is to be carried to site and includes carriages, head loads, all leads and lifts. |
| 88 | Supply, installation, erection of MS tubular poles of 9 mtrs long (SP- 33) having reduced dia. of 4”x5” x 6” from top to bottom and shall be anti-corrosive painted. The job includes providing / laying of cement concrete in 1:2:4 cement, sand aggregate block for grouting of each pole. The pole shall be fitted / welded with 40 x 40 squares in size and 10 mm thick MS plate at the bottom and having duly drilled holes at top at appropriate position for accommodating MS fasteners for holding crosses and safety devices. Job includes, earthing and the cost of black painting of poles up to a height to 1.50 mtrs and the top with a silver shade |
| 89 | P/F of 9’ long ISMC 100 channels for transformer bed. |
| 90 | P/F of 9’ long ISMC 75 channels for fitment of link set, D/O set & lightening arrestor set etc |
| 91 | P/F 3-phase heavy duty G .O setsuitable for 11 KVA at tapping point so as to ensure safety during maintenance of the HT line. The job includes costs on a/c labour, handling, carriage, channel iron required for fitting ,nuts and bolts etc. |
| 92 | P/F 11KVA -3 phase drop out set |
| 93 | P/F of lightening arrestor set station type. |
| 94 | P/F 11KVA -3 phase G .O set complete with links and lever operating mechanism |
| 95 | P/F of the arrangement (Belt) to hold the transformer firmly and securely to the substation. It is to be fabricated out of ISA(40x40x5)mm C/w nuts & bolts |
| 96 | P/F of Cross arms fabricated out of ISMC 75 of 5 ft length to carry insulators duly drilled with suitable size holes for accommodating nuts bolts. |
| 97 | P/F of ISA 40—5 ft long as braces for above crosses duly drilled with suitable size holes for accommodating nuts bolts for proper fitment. |
| 98 | P/F 11KVA pin insulators ( polymer) with pins to be fitted on poles |
| 99 | P/F of danger plate with clamps with writing in English / regional language. |
| 100 | P/F of anti climbing devices complete with nuts and bolts |
| 101 | P/F of 0.05 ACSR Aluminum conductor |
| 102 | P/F of G.I wires SWG 8. |
| 103 | Providing, Installation of earthing station comprising of company fabricated earthing electrodes as per IS: 3043. The job includes Auguring of bore of required dia. / depth for installation of electrode along with black fill compound mixed with soil and all other items required thereof for achieving the best result The job includes connecting of electric gadgets, DG set through GI stripe making of surface structure in brick / cement concrete material as per drawing annexure. Safe earthing electrode size 80 mm dia.length- 2000mm Blackfill - 30 Kg Model / make-JMV-392, Ashlok, Recons |
| 104 | P/F of PRODIGY LT meter of following specificationsfor above Sub station c/w all fixtures required for fitment at site. Type: E3L100, 3Ph, 4Wire (KWh , kVArh, kVAh, kVA) 3x240(415)V,50HZRef Temp: 270C400 pulses/unitBattery : LithiumIb:40A Imax 200A |
| 105 | P/F of Switchgear unit consisting of 200 Amp. 4 – pole MCCB 3,phase,415 V, 50 KA breaking capacity make L&T housed properly in an outdoor type cubical Panel fabricated out of MS SWG-16 sheet steel |