| 1 | Erection of RCC Poles 11Mtr. long CEE/E-698, R-3 along with labour and material. |
| 2 | GI Stay rod with plate LT/11KValong with labour and material. |
| 3 | GI Turn buckle with eye bolt 11KV |
| 4 | Stay wire 7/10 SWG wire |
| 5 | Break Insulator, 8KV |
| 6 | GI Nut & Bolts 100 X16mm |
| 7 | HDGI stayclamps for RCC pole 11 mts long |
| 8 | HDGI \"X\" arm clamps for RCC pole 11 mtr long |
| 9 | HDGID.P.Structurematerial (for mounting of 1sets. 11KV GOAB switches) |
| 10 | 11KVGOAB400amps 3PoleCEE/E-670 withoperating pipe supportof classB, 25mm.Dia. |
| 11 | HDG Cut point channel of 1.3 Mtr. long of channelISMC75 x 40 x 7.3 mm |
| 12 | DiscInsulator70KNwithmetalparts. |
| 13 | ACSRWEASEL CONDUCTOR 6/1/2.59 (nominalaluminium area 30 Sq.mm.) (139 amp max at 45 °C.) |
| 14 | G.I.Earthingpipe8\" long 40mm.DiaclassB,Fabricated&perforatedincludingalternatelayers30Cm.Thick of charcoal, salt, & earth (charcoal & salt 10 Kgs. each for per pit) inclusive of excavation, backfilling and spreadingofexcavated earth evenly. |
| 15 | Enamelled danger boards 11000 VoltsCEE/E-490. |
| 16 | Anti climbing device |
| 17 | 9KV,5KALightningarrestor |
| 18 | 11KV INCOMING CABLES & ASSOCIATED EQUIPMENT |
| 19 | 3 WAY RMU, 11KV, 630A, 21 kA 3Sec, SF6 Outdoor RMU – 2LBS + 1CB Extensible/Non-Extensible Two (2) Motor operated load break switches (LBSs) with Manual operated earthing switches in SF6 and One (1) vacuum circuit breaker with Electrical closing and tripping along with disconnector and earthing switches SCADA Compatible and base channel. Battery charger along with batteries required for Electrical operations of RMU is in the scope of the Bidder. Each module shall consist of VPIS, FPI in LBS Module (N-1) but not less than 1 no’s per RMU. Suitable arrangement for mounting FRTU, modem or Ethernet Switch/LIU along with battery, battery charger shall be provided in RMU. |
| 20 | G.I.Earthingpipe8\" long 40mm.DiaclassB,Fabricated&perforatedincludingalternatelayers30Cm.Thick of charcoal, salt, & earth (charcoal & salt 10 Kgs. each for per pit) inclusive of excavation, backfilling and spreadingofexcavated earth evenly. |
| 21 | XLPE cable 11KV 3C X 300 sq.mm armoured (pole to RMU) |
| 22 | XLPE cable 11KV 3C X 95 sq.mm armoured (RMU to transformer) |
| 23 | Warning Tape |
| 24 | H.S 11 KV Termination kit indoor 240/300 XLPE 3 core |
| 25 | H.S.11 KV Termination kit outdoor 240/300 XLPE 3 core |
| 26 | H.S 11 KV Termination kit indoor 50/95 XLPE 3 core |
| 27 | H.S.11 KV Termination kit outdoor 50/95 XLPE 3 core |
| 28 | Excavation in any type of soil including hard laterite soil. |
| 29 | Refilling of excavated soil |
| 30 | Sand for cushioning of HT underground cables. |
| 31 | RCC Slab 600x250x50 mmBreaking Capacity-135 Kg as a protective cover for underground cables. |
| 32 | GI Pipe 150mm class B |
| 33 | RCC cable route marker |
| 34 | DTC and Associate Equipments |
| 35 | 400 KVA 11kv/.4kvDistribution Transformers level II losses, Copper Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014, suitable for outdoor use and for plinth mounting. |
| 36 | DistributionTransformer Metering unitwith DLMS/COSEM protocol energy meter with modem |
| 37 | G.I.Earthingpipe8\" long 40mm.DiaclassB,Fabricated&perforatedincludingalternatelayers30Cm.Thick of charcoal, salt, & earth (charcoal & salt 10 Kgs. each for per pit) inclusive of excavation, backfilling and spreadingofexcavated earth evenly. |
| 38 | S&E of GI earthing strip of size 25x5 mm for connecting earthing pipe to other equipment |
| 39 | Outdoor, LV Switchboard with 1 no. 1000A ACB incoming and 4 nos. 320Amps MCCB outgoings suitable for 400KVA Transformer centre made out of CRCA sheet with PU paintedcomplete with all accessories and HDGI mounting channels. |
| 40 | LT UG cable from Transformer to LV panel to metering panels |
| 41 | Excavation oftrench of size 0.3 x 0.9 x 25 mts in any type of soil including of opening of road etc forlaying of cable of size 3 ½ core 300sq.mm & 3 ½ core 185sq.mm |
| 42 | Supply,transportation to site and laying of 3 ½ coreXLPE insulated armoured cable of size 3.5 x 300 sq.mm, 1.1 KV grade as per I.S. standard, with acessories. |
| 43 | Filling of available excavated earth (excluding rock/stones) in trench, plinth, sides, foundations etc. in layer not exceeding 0.2mts. depth consolidating each deposited layer by ramming and watering lead up to 54mts. (0.7x0.3x40) |
| 44 | Kaddapa ofsize 600mm length x 250mm width x 37mm thick as a protective cover for underground cables. |
| 45 | Sand for cushioning of the cables in the trench. |
| 46 | Providing and laying in position cement concrete 1:2:4 ( 1 cement :2 coarse sand :4 graded granitic or basaltic stone aggregate 40mm nominal size) excluding cost of centering,shuttering and finishing (for plinths of 400KVA transformer, RMU,LV panel) |
| 47 | Centering & shuttering including struttings, propping etc & remonal of formwork |
| 48 | 12mm cement plaster 1:4 (1 - cement: 4 - fine sand) for foundations. |
| 49 | Brick work using common burnt clay building bricks in cement mortar 1:4 ( 1-cement: 4 - coarse sand) in foundation and plinth (b) with bricks of class designation 75 kgs/sq.mm (wire cut bricks) |
| 50 | Al. Crimping lug 300 sq.mm |
| 51 | Aluminium crimping lugs 150 Sq.mm |
| 52 | FRP Fencing complete with Gate as per specification for Distribution Transformer ( Size x 4Mx3Mx2M) with Concreting for FRP fencing Supports with plinth (0.3x0.3x0.5) Cu.mx12nos.Each ratio 1:3:3 |