Tender For Development Of Mashiche Mal Ground With All Sports Facilities In Ward No. 05 At Nanus Vado Valpoi Phase Ii, panaji-Goa

Goa State Urban Development Agency -GSUDA has published Tender For Development Of Mashiche Mal Ground With All Sports Facilities In Ward No. 05 At Nanus Vado Valpoi Phase Ii. Submission Date for this Tender is 22-06-2023. Playground Construction Tenders in panaji Goa. Bidders can get complete Tender details and download the document.




Tender Notice

37917805
Corrigendum : Tender For Development Of Mashiche Mal Ground With All Sports Facilities In Ward No. 05 At Nanus Vado Valpoi Phase Ii
Open Tender
Indian
Goa
panaji
22-06-2023

Tender Details

Development Of Mashiche Mal Ground With All Sports Facilities In Ward No. 05 At Nanus Vado Valpoi Phase Ii

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-06-2023
2 14-Jun-2023 Corrigendum Other 22-06-2023

Key Value

Document Fees
INR 6000 /-
EMD
INR 1657041.0 /-
Tender Value
INR 8.28 Crore /-

BOQ Items

Name of Work: DEVELOPMENT OF MASICHE MAL GROUND WITH SPORTS FACILITIES IN WARD NO. 05 AT NANUS VADO VALPOI , GOA (PHASE II)
Sl. No. Item Description
1Earthwork in excavation over areas/Trenches by mechanical/mannual means at all depths( till 3 mt) in all types of strata’s comprising of the materials such as soil, silt, sand, clay, gravel moorum of all varieties shringles, pebbles, all types of conglomerates laterite rocks, ordinary rocks, disintegrated rocks, fissured / shattered rocks decomposed rocks or weathered rocks and all such other materials as described under appendix “A” to these specifications either in full or in parts as the case may be adopting any method / methods as may be convenient or permitted inclusive of blasting chiseling wedging etc. in all conditions such as dry, moist foul submerged saturated etc. and as directed by the Engineer-in-charge, etc. all complete including dressing of sides, ramming of bottom including all leads and lifts including getting out the excavated soil as directed including pumping and bailing out water, barricading danger lighting guarding as directed by the departmental officers.
2Filling n plinth and floors with contractors material /brought from outside and approved by Engineer incharge in layers of 15cm to 20cm including watering and compaction etc. complete.
3Refilling the plinth , flooring, foundations etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.
4Loading and unloading of excavated earth.By mechanical transport including loading , unloading and stacking upto a lead upto 10 kms
5Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
6Providing anti – termite treatment to buildings conforming to I.S.S. 6113 part II 1971 (revised) including adoptingprecautions for health hazards and safety measures as required therein with the cost of all materials, chemicals, plants, equipments required for the treatment and furnishing a guarantee for a minimum period of 10 years from the date of completion including eradicatingany infestation of termite free of cost during the guaranty period complete. (The payment will be made on plinth of the building.(a) Pre-construction
7Providing anti – termite treatment to buildings conforming to I.S.S. 6113 part II 1971 (revised) including adoptingprecautions for health hazards and safety measures as required therein with the cost of all materials, chemicals, plants, equipments required for the treatment and furnishing a guarantee for a minimum period of 10 years from the date of completion including eradicatingany infestation of termite free of cost during the guaranty period complete. (The payment will be made on plinth of the building. (a) Post-construction
8Making plinth protection 50mm thick of Cement Concrete 1:3:6 (1cement: 3 Coarse Sand: 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry laterite aggregate 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
9Providing and laying in position cement concrete 1:2:4(1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size) excluding cost ofcentering,shuttering and finishing : All works upto plinth level
10Providing and laying upto floor five level cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20 mm nominal size) including smooth finishing to exposed surfaces, with cement mortar 1:3 (1 cement: 3 fine sand) including centering and shuttering etc.
11Providing and laying in position ready mixed concrete (RMC) with usage of Ordinary Portland Cement manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead upto 10kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C., from the transit mixer to the site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including the cost of admixtures in recommended porportions as per IS : 9103 to accelerate/retard setting of concrete, improve workability without imparing strength and durability as per the directions of the engineerin- charge. All works upto floor V level: M-30 grade of concrete
12Providing and laying in position ready mixed concrete (RMC) with usage of Ordinary Portland Cement manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead upto 10kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C., from the transit mixer to the site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including the cost of admixtures in recommended porportions as per IS : 9103 to accelerate/retard setting of concrete, improve workability without imparing strength and durability as per the directions of the engineerin- charge. All works upto floor V level: M-25 grade of concrete
13Centering & shuttering including Strutting, Propping & removal of forms for: Foundations, Footings, Bases for columns
14Centering & shuttering including Strutting, Propping & removal of forms for:Columns, Piers, Pillars, Abutments, Posts and struts (square rectangle polygon in plan)
15Centering & shuttering including Strutting, Propping & removal of forms for:Vertical surfaces such as retaing walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like
16Centering & shuttering including Strutting, Propping & removal of forms for:Staircases (except spiral staircases) excluding landing
17Centering & shuttering including Strutting, Propping & removal of forms for:Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, Bressumers and Lintels plinth beams not exceeding 1m in depth
18Centering & shuttering including Strutting, Propping & removal of forms for:Suspended floors, roofs landings, shelves & their supports
19Extrafor additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de- shuttering and de-centering at all levels, over a height of 3.5m,for every additional height of 1m or part thereof. (Plan area to be measured) Suspended floors, roofs landings,beams & balconies.(From 3.50m upto 4.50m)
20Providing TMT steel reinforcement (Confirming to IS 1786 of 1986)for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floorsalongwith the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
21Brick work using fly ash bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with bricks of class designation 40 kgs / cm2. in foundation and plinth.
22Brick work using fly ash bricks in cement mortar 1 : 4 (1 cement: 4 coarse sand) with bricks of class designation 40 Kg / sq. cm, in superstructure upto floor V level. Brick size 230mm X 110mm X 80 mm
23Providing and laying half brick masonry usingfly ash bricks in cement mortar 1:3 (1 cement : 3 coarsesand) with 2 nos of 6mm dia M.S bars at every third course embedded in cement mortar above plinth upto floor V level.(With bricks of class designation 40 kg/sq.cm.)
24Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces,in all positions including scaffolding and curing etc. complete.
25Providing internal cement plaster 6mm thick in a single coat in cement mortar1:3without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.
26Labour charges for providing groove in external plaster having width and spaced as directed by engineer incharge etc. complete.
27Providing 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge.
28Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
29Distempering two or more coats with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade.
30Wall painting(two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade.
31Painting three or more coats with acrylic exterior paint of approved brand and manufacture (such as weather shield, APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete.
32Finishing wall with waterproofing cement paint of approved brand and manufacture and of required shade on new work (three or more coats) to give an even shade.
33Applying priming coat with ready mixed red lead paint of approved brand and manufacture on steel work.
34Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade.
35Providing and and laying vitrified floor tiles in different sizes of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigment etc., complete. 600x 600 mm Dark Shades
36Providing and laying vitrified Antiskid floor tiles in different sizes of Johnson, Somany,Kajaria (thickness to be specified by the manufacturer) and conforming to IS:15622 of approved make in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigment etc., complete. 300 x 300 mm dark Shades - 10mm thick
37Table tennis: Supply and of Gerflor make SyntheticSports Flooring. Technical Specification: TARAFLEX EVOLUTION (Made in France) or equivalent, an overall thickness of 7.5 mm synthetic sport surface comprising of PUR Protect® treated + > 2.1 mm vinyl surface layer, calendared and grained, associated with PVC density single closed cell foam, reinforced by a fiberglass grid structure reinforcement, Sanosol treatment for fungistatic and bacteriostatic properties, Weight: 4.7kg/m2, Impact resistance (EN 1517) =8 N/m, Abrasion resistance (EN ISO 5470-1) =350mg, Shock absorption (EN14808) =25% class P1, Indentation resistance (EN 1516) =0.5mm, Ball bounce (EN 12235) = 90%, Vertical deformation (EN 14809) =2mm, Sliding coefficient (EN 13036-4) 80 – 110, Fire (EN 13501-1) Cfl-s1, Anti-Viral activity (human coronavirus 229E) – ISO 21702….99.37% (after 2h00) Energy return (NF P 90 203) = 0.31m/s, TVOC after 28 days <100 microgram /m3 according to ISO 16000-6, Floor Score®, CE Marking specification for indoor surfaces for multi-sports use (EN14904), REACH compliant, Singapore Green Label certified.Federation Approvals: The synthetic flooring must comply with international standards and homologated by BISFED, BWF, FIBA, EHF, IHF, AFC, IFF, AVC and complete with 10 years’ manufacturer’s product warranty.
38Kotah stone slab flooring over 30 mm (average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid over & jointed with grey cement slurry mixed with pigment to match the shade of the slabincluding rubbing & polishing etc. complete. 20mm thick
39Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer : Flamed finish granite stone slab.-Elite Brown
40Rubber Skirting: Factory supplied 75mm x 100mm rubber base molding to include air channelling in back of base to provide full ventilation of the sub-floor system.Fixed to the wall with a base molding adhesive as recommend by manufacturer
41Providing and fixing Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps and dados, jointing with grey cement slurry @3.3 kg per sqm, including pointing/grouting in white cement mixed with pigment of matching shade complete.:600 x 600 mm - Dark Shades
42Providing and fixing Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps and dados, jointing with grey cement slurry @3.3 kg per sqm, including pointing/grouting in white cement mixed with pigment of matching shade complete.600 x 600 mm - light Shades
43Kotah stone slab flooring over 25 mm thick in risers of steps, skirtings, dado & pillars laid on 12mm (average) thick cement mortor 1:3 (1cement : 3 coarse sand) & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete.
44Providing and fixing Granite stone slabs (flamed finish) 18mm thick in risers of steps, skirting, dado and pillars laid on cement paste and jointed with grey cement slurry mixed with pigment to match the shade of the slabs,including rubbing and polishing complete-Elite Brown
45Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade, area of slab over 0.50 sqm-Jet Black
4652mm thick cement concrete flooring/ IPS Flooringwith metallic concrete hardener topping, under layer of 40 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layers 12 mm thick metallic cement hardener constituting of mix 1:2 (1 cement: 2 graded stone aggregate 6 mm nominal size by volume with which metallic quality is mixed in ratio 4:1 (4 parts of cement: 1 part of metallic) hardening compound of approved floor hardening compound of approved quality) by weight, including finishing complete.
47Providing and laying 20mm thick cuddapah in shelves over 20 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) etc.complete
48Providing 25 mm thick cuddapah slabs machine cut and polished on either side in partitions including making necessary grooves in the wall and fixing with cement mortar, complete as directed by the Engineer
49Full/half rounding and polishing of edges ofgranite slab as per the requirement.
50Supplying and fixing CI manhole cover and frame of 445x610 mm rectangular C.I. cover (light duty) weight of cover to be not less than 23 kg. as per specification and as directed.
51"Supply and Installation of MAPLEwood sports flooring as per specifications and conditions mentioned Hard maple flooring: MFMA approved Hard Maple wood Flooring 20mm thick each individual strip of Hard Maple shall include the engraving of the MFMA Maple Flooring Manufacturers Association and manufacturing mill certification number. Minimum width of Hard Maple boards is 57mm and of random length varying from 230mm to 1800mm jointed together with the help of tongue and groove on all four sides of all boards. Substructure: Substructure of maple wood flooring shall consist of sleeper of Spruce or Pine having 63mm wide and cross section of 38 mm and laid perpendicular to the main flooring planks at a spacing 305mm centre to centre including 19 mm thick rezill pads at 305mm centre to centre spacing and polyethylene membrane installed over the concrete base beneath the flooring system as a vapour barrier between the concrete and wood floor. Vapour Barrier: .20mm polyethylene membrane installed over the concrete base beneath the flooring system as a vapor barrier between the concrete and wood floor. Finish: Machine sanding two coats of oil modified Poly urethane Gym sealer and one coat of oil modified Poly urethane Gym sports finish in accordance with manufacturer specification and Game line marking in accordance with manufacturers specifications and project drawings etc complete to the entire satisfaction of Engineer-in-charge. FIBA (Federation International Basketball Association). WSF (World Squash Federation)"
52Supply and installation spike resistance rubber flooring for Locker room it consist of colour rubber granules and 30% synthetic EPDM granules floor should be Environmental friendly, non-toxic, Recycled , non-polluted, anti slip and anti-fatigue Laid with adhesive as per manufacturer’s instruction over existing leveled surface with following Technical specification. 6mm
53Providing 20mm thick marble slab to urinal partitions with cement complete
54Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/Cuddapah stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
55Providing and fixing M.S. fan clamp type 1or II of 16 mm dia M.S. bar bent to shape with hooke ends in R.C.C. slabs, beams during laying including painting the exposed portion of loop, all as per standard design complete.
56Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing "C" wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of GI steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring "T" with :b) GI Metal Ceiling Clip in plain Beveled edge global white colour tiles of size 600x600 and 0.4- 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.
57DOUBLE SKIN ALUMINIUM STANDING ROOFING SYSTEM Supply and fixing of“SELF SUPPORTED” SECRET FIX STANDING ROOFING SYSTEM IN 0.9mm THICK AA 3004/3005 ALUMINIUM ALLOY. The general roof-construction shall comprise from top to bottom : Top layer –65/400 Straight/Curved profile sheeting manufactured from aluminium self supported standing seam roof system from aluminium alloy AA 3004/3005 H46 (AlMn1Mg1) as specified in BS EN 1396: 2015 material thickness of 0.9 mm and in finish of PVDF2 consisting of anti corrosive primer of 5 microns, topcoat of PVDF in 20 +/-2 microns with the Total coating thickness as 25 Microns. The coil for the top panel shall have 75 microns transparent protective guard film with the roofing manufacture name printed, This Guard film prevents scratches during roll forming & handling. The standing seam sheet panel of approved make shall be fixed on to the purlin using aluminium ST clips. The head of clips shall be fixed accurately to ensure the roof sheeting to expands and contracts freely during thermal movement. The material properties shall be as follows: Ultimate tensile strength minimum 200 N/mm2, 0.2% Proof Stress: min 185 N/mm2, Sheets are to be laid to meet the requirements of the building geometry and fixed on aluminum clips. Clip to be fixed with SS 304 screws only. Second Layer – Rockwool insulation of 100mm thickness and minimum 60 kg/m³ density with thermal conductivity of K=0.038 W/mk at 20 degrees Celsius when tested to ASTM C518.
58Aluminium Flashing Flashings manufactured from aluminium alloy AA 3004/3005 (AlMn1Mg1) as specified in BS EN 1396: 2015 material thickness of 0.9 mm & same finish as panel. Flashing girth to be 400mm to 500 mm.
59Aluminium Gutter Supply and fixing of Single skin 2 mm thick Aluminium gutter, GRADE AA 1100 ALLOY with EPDM Expansion joints for every 6/8 mtrs length based on the girth of the Gutter, Down take spout dia 150 mm at every 10m gutter length, & other accessories and welding at joints. The Girth of gutter would be maximum 1200mm OR as per Project requirement.
60Double SKINFaçade System: Supply and fixing of TF 800 profiles IN 1 mm THICKNESS AA 3004 ALUMINIUM ALLOY, comprising of the following layers: Exterior Layer: Designing, providing and fixing TF 800 R in 1.0 MM THICK AA3004 ALUMINUM ALLOY comprising of sheets in 800 Mm widths, and in lengths up to 5.8 mtrs or as per site requirements and finished in PVF2 colour – (Shade as approved by Architect). Each module shall,further comprise of three 267 modules and each module with two downward pointing triangular profile , of 67 mm widths , which shall have a radius bend of 3mm . The sheeting having a nominal value yield strength at 0.2% proof stress R p0.2 =185N /mm2 .The sheets shall confirm to the Characteristics load bearing Capacity according to DIN 18807 ,part 6.The panels shall be mechanically fixed to suitable substructure of MS/ aluminum at every 2nd small lower Flange, at 120 mm from the panel ends and a maximum centre to centre distance of 1300 mm OR AS REQUIRED BY THE WIND LOAD at the specific site. The Sheeting shall be finished with PVF2 . Nominal organic coating thickness - 25um – EN13523 1 Second Layer – Rockwool insulation of 100 mm thickness and minimum 60 kg/m³ density with thermal conductivity of K=0.038 W/mk at 20 degrees Celsius when tested to ASTM C518. (Make Rockwool India/Roxul) . Third Layer – Vapour Control Layer - A single layer film reinforced polyester yarn a six layer double sided Vapor control barrier, consisting of lamination of pure aluminum foil, aluminum film and high quality kraft paper reinforced with polyester yarn, thickness of 180-200 microns thickness, with tensile strength of N/25 mm in the machine direction of 150-170 and Water Vapor Transmission tested as per ASTM F1249 @ 0.08 - 0.2. g/m2/day. Fourth Layer - Solid 35 /200 Galvalume steel liner 550 MPa, 0.5mm TCT 1000 mm total cover width 35mm deep ribs. Purlin Spacing shall be advised by the roofing manufacturer. The panel shall be manufactured out of Hi tensile pre-painted Zincalume/Galvalume steel- AZ150 (min. 150 gms/sq.mt total on both sides) having minimum yield strength of 550 MPa. The finish to the exposed surface of the liner will be polyester coating with film thickness of 15 to 20µm +/- 2 µm
61POLYCARBONATE FOR FAÇADE:Providing and Fixing of Multi cell Polycarbonate Panels 16mm thick with 5 cells - 6 walls structure with panel width shall be 900mm to ensure best performance for wind uplift. The panels shall be uniform in colour with an integral Multi-Cell core with soft light finish to give diffused light. In a cross section, the core shall be constructed of Microcell of max 4mm x 4mm.The appearance should be rectangular. Panels shall be coextruded with UV Protection layers of certified minimum 50 microns to filter harmful UV rays. The weight of the panel shall not be less than 3250 gram per square meter. Panel shall have U value not more than 1.9 W/m2 k and UV transmission less than 0.1% as per UV filtration test AS No.1067-1990.Panels shall have Vertical Standing Seam of 15mm at both sides with Snap-on connector to interlock the panels shall have a2 tooth grip-locking mechanism to ensure maximum uplift capability. Panels shall be fixed on Purlins with special SSExpansion fastener with design load of 250kg/clip and polycarbonate U/2 connectors. Panels shall have impact and shockresistance of soft and hard body impact of D1-10J - M50,300J - M50,400J. Panel should pass Sandbag impact test AS/NZS4040.4-1996 and water penetration test ASTM E -331. Panel should have certification of B S1 D0 for reaction to fire testunder EN 13501 – 1:2002. Panels shall have Yellowness Index as per ASTM D-1925 or equivalent and the delta changeshould not be more than 10 points from original after 60 months of exposure. Panels shall pass colour change test according to ASTM D2244 and delta change shall not be more than 3 units from the original after exposure of 60 months. Panels shallpass Light Transmission test ASTM D1003 and light transmission of panels shall not decrease more than 6% after 10 years. Translucent polycarbonate system Materials and Products shall be manufactured by a company continuously and regularlyemployed in the manufacture of translucent systems using polycarbonate panel systems for a period of at least ten (10) years and same period should be applicable for warranty of panels. Panels shall be manufactured with approved quality assurance as per ISO 9001 & ISO 14001. Third party test certificates to be submitted before supplying the materi
62Providing water proofing treatment over the new R.C.C. roofs, terrace, toilet by spreading cement slurry over the R.C.C. slab and laying of10cms. Average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba in covered with damp proof of Hindustan water proofing co. Or equivalent jointless water proofing plaster of mix 1:3 ( 1 cement : 3 find sand), finished smooth with wooden trowel with false marking of 30 cms square. The vertical surface of the adjoining walls are to be treated upto a height of 30cms including rounding of junction (the rate includes for complete items including labour and materials and including cost of initial treatment of roof slab as follows. The injunction of damp proof or equivalent compound with cement solution will be given as and when found necessary for filling honey comb, cracks etc. inthe R.C.C. slabs). NOTE: cement consumption 25 kg/sq.m.(Terrace, Sunken Portion of WC"s, Toilet, Kitchen etc)
63Providing woodwork in frames of doors, windows, clerestory windows trusses & other frames wrought framed and fixed in position.Second class Indian teak wood
64Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type (BWP), core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
65Providing and fixing hydraulic floor spring of reputed make Everrite, prabhat or equivalent as per the manufacturer"s as specification having double action spring as approved by the Engineer-in-charge.
66Providing and fixing brass hydraulic door closer of make Everest universal 68 or equivalent with necessary screws and fittings complete.
67Providing and fixing chromium plated brass butt hinges with necessary screws etc. complete125 x 70 x 4.0mm (ordinary type)
68Providing and fixing chromium plated brass butt hinges with necessary screws etc. complete 75 x 40 x 2.5 mm (ordinary type)
69Providing& fixing chromium plated brass tower bolts (barrel type) with necessary screws complete.250 x 10 mm
70Provided and fixing 150 mm chromium plated brass floor door stopper with rubber cushion screws etc. to suit shutters thickness complete.
71Providing and fixing chromium plated brass handle with necessary screws etc. complete.-125mm
72Providing flat iron hold fast 40 cm including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedded in cement concrete block 30 x 10 x 15 cm 1:3:6 mix (1 cement: 3 coarse sand: 6 stone aggregate 20 mm nominal size.
73Provided and fixing chromium plated brass 100 mm. mortice latch and a pair of levers and handles with necessary screws etc. complete (Indian make of approved quality).
74Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
75Design, supply & installation of suspended Spider Glazing system (Frameless glass structural glazing) designed to withstand the wind pressure as pr IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding , other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.
76Extra over design, supply and installation of Spider glazing system, for provision of 12mm thk clear toughened glass door shutter fittings including the cost of top & bottom patch fitting, over panel patch, panel connector pivot, over panel/sidepanel connector with pivot, bottom lock, stainless steel hardware fittings of 316 grade for operating door i.e. door handle 450mm Lg, floor spring of approved make and locking arrangement etc. complete including the cost of cutting the floor and making good the same, as per design and drawing all complete as required.
77Providing and Fixing mat finish stainless steel (of 302grade) railing with top pipe of 50mm dia. and vertical pipe of 38mm dia at 0.60m c/c or as required and horizontal pipes of 25mm dia in three rows, all pipes of 2mm thick including buffing, fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75mm dia above newel post of 75mm diameter etc.complete (Prior approval of sample and brand by Ex.Engineer is necessary before use)
78Providing and laying of aluminium fixed with 65mm x 38mm tubular frame with 6mm thick glass sections are powder coated with pure ployster powder of thickness 75-80 microns with approved standard accessories. The glass would be fixed with taper clips with EPDM beading and including filling gaps with silicone sealant of approved make etc complete. (Shop drawing to be submitted by contractor for approval.)
79Supply and installation of Aluminium Louvers. The frame should be made of Aluminium tubes of size 100x50X1.50 mm thk and 50X25x1.50 mm thk C channels. Aluminium Z shaped louvers of 100mm should be fixed to the supporting frame with aluminium cleats, GI screws, etc complete. The whole assembly is powder coated with pure polyester paint. (MS framing to be paid separately)
80Steel work(SAIL, TATA. VIZAG only) riveted or bolted in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead paint.In tees, angles, flats and channels
81Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of (SAIL, TATA. VIZAG, JSW ,APOLLO Steel Ltd.) make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
82Providing and fixing Toilet cubicals as under with door, pilaster and divider of 18mm thick boardboth side decorative compact laminate ofrequiredcolour,shadeand sizesas manufacturedbyBescoby MerinoorGreenlamSturdoor T Line or equivalent as approved,includingstainless steel accessories ( SS-304 grade)like square top rail. Front panel and divder wall with stripe shoe touching floor ( No gap shall be at bottom of divder/front panel except door) , knob, thumb turn and indicator, twincoathook,doorstopper,adjustableshoe,gravityhinges,andlockingarrangement, SSchanneletcasdesired.all complete as per drawings . The cubical unit shall be installed in approved finish, shades and colours as per specifications and direction of Engineer in charge. The cubical unit shall be minimum 10 years guarantee for the board against any moisture and 5 yearsguaranteeforthehardwares. (Cubicalsize=(900mmwidthx1500mmdepth),CubicalHeight=2100mm,External Laminate finish = Metallic).
83Table TennisTable :- Supplying and Installing ITTF approved Tables for Table Tennis. The playing surface of the table shall be rectangular, 2.74m long and 1.525m wide, and shall be in a horizontal plane 76cm above the finished floor. The playing surface Should be 21 mm thick andshalll not include the vertical sides of the table top. The playing surface shall yield a uniform bounce of 1bout 23cm when a standard ball is dropped on to it from a height of 30cm. The playing surface shall be divided in to two equal courts by a vertical net running parallel with the end lines, and shall be contineous over the whole area of each court. As directed by Engineer-In-Charge.
84Basketball- Supply movable Hydraulic basketball post The base of the frame shall consist of structural steel tubing, comprising of 100X80X5mm,square tubing, and formed sheet metal parts welded Together to form a rectangle. The base weldment supports 2 structural steel columns consisting of100x60x5mm,40x40x5mm steel tubes welded. Together. The columns are supported on hinges with Ø40mmshaft at bearing ends on the base. On the columns is supported the overhang beam of 25x125x5mm tube holding the backboard. The overhang beam shall have an extension of 3200mm” from the front base pad to the front of the backboard glass. The unit will come preassembled with 600kg. of ballast weight. 2 heavy-duty swivel casters with one 150mm nylon wheel on each side rated at 500kg. no harm Folding: The folding mechanism will be available in two different 1) high power hydraulic cylinder with manual cranking, taking only minutes to raise and lower. The unit shall come with a positive lock at the 8’, 9’, and 10’ playing positions and can be adjusted to meet severalheights in between. Padding: All front padding shall be a minimum of 5.5” thick foam .All base side padding shall be a minimum of 3” thickfoam. Standard padding color shall be Blue
85Badminton Pole Made from dia 42 round tube powder coated with 100kg. of ballast weight. Roller wheels to be provided for facilitating easy transport and storage. Post should be designed for strength and stability, to support net and Manual winch is provided for tightening the net. with a large base. Post should maintain the stability with Badminton Net. As per Instructions directed by Site engineer
86Volleyball Post: Volleyball UprightsUnder floor L300mm,76.3mm 60kg/pair Internal bevel gear system, Special cold drawing steel tube construction. Fine height adjustment for multiple floor heights.
87Acoustic Panel: Supply and installation of Stretch Hush fabric system consisting of FR Grade Hush fabric-based membrane with high-performance Polyester core and acoustically-transparent face covering of choice colour, size 1.4mx75m, stretched by using combination of Strut CC50 Cross Channel and Strut FS25 Tracks, Strand 600x1200x15mm, 10mm woodenbase, SynthPF 10x50,10x10 infill with requisite accessories.Technical Parameters of system• Fire (Class) – 1& P • Acoustics – NRC 0.9 (For 12mm thk C50 Mounting) • Thermal conductivity (W/mk)– 0.07 • Climate (°C, RH) – 50, 95 • Light reflectance (%) – Color Dependant • Green (VoC, RC %) – Low,30
88Proving and fixing white vitreous china Wall Hung type (European Type) water closet with seat and lid with C.I. brass hinges and rubber fittings with flush valve nelson/ similar fully chromium plated with stop cock, wall flanges, flush pipe or elbow and vaccum breaker coupling etc. including chair bracket/rag bolts, cutting & making good the walls and floors where required and concealed seat support - W.C. Pan with white plastic seat and lid
89Providing and fixing white vitreous china flat back Large lipped front urinal basin of 590x375x390mm size with Urinal Valve Auto closing system with built in control cock & wall flange with fittings, spreader, R.S. or C.I. brackets, standard size C.P. Brassl flush pipe and spreaders with C. P. brass unions & C. P. Brass clamps with waste fitting as per IS 2556, PVC trap with outlet grating and other couplings in CP Brass complete, including painting, fittings, cutting and making good the walls and floors where required. - Range of one urinal basin
90Providing and fixing white vitreous china pedestal for wash basin complete recessed at the back for the reception of pipes and fittings.
91Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 including cutting of stone and making good the walls wherever required. Kitchen sink without drain board. with coupling & all accessories complete with choke stop strainer, Plain type having flat borders for correct sandwithing between the plaform top and bottom slabs complete. Overall size 610mmx510mm (24"x20") bowl size 545mmx445mmx200mm (211/2"x 17 1/2"x 8") depth 200 mm. Glossy. 1.0mm thk,
92Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 including cutting of stone and making good the walls wherever required. Kitchen sink without drain board. with coupling & all accessories complete with choke stop strainer, Plain type having flat borders for correct sandwithing between the plaform top and bottom slabs complete.Overall size 610mmx460mm (24"x18") bowl size 560mmx410mmx215mm (22"x16"x81/2") Glossy. 1.0mm thk, Each 5785.00
93Providing and fixing G. I. Inlet connection for flush pipes connecting with W. C. pan.
94Providing and fixing C.P. brass or M. I. Trap for wash basin and sinks: 40 mm dia
95Providing & fixing (4’) 100 mm sand cast iron grating for gully floor or nahni trap.
96Providing & Fixing In Position 25 mm diameter mosquito proof coupling of approved municipal design.
97Providing & fixing bevelled edge mirror of superior glass (5mm thk) of approved Quality, shape & size complete with CP brass screws and washers, Cleats, CP studs etc Complete.
98Providing & fixing c.p. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C. P. brass screws 750 x 20 mm size
99Providing and fixing toilet paper holder :C.P. brass
100Providing & fixing liquid soap container with C.P. brass lid and brackets fixed to wooden cleats with C. P. brass screwsGlass container
101Providing and fixing NICKEL chrome plated copper alloy Fancy BIB Cock Short Body Jaquar make or equivalent. Confirming to IS 8931;1993 15mm nominal bore
102Providing and fixing NICKEL chrome plated copper alloy Fancy long body bib cock with wall flance Jaquar make or equivalent. Confirming to IS 8931;199315mm nominal bore
103Providing and fixing NICKEL chrome plated copper alloy Fancy two way long body bib cock with wall flance Jaquar make or equivalent. Confirming to IS 8931;199315mm nominal bore
104Providing and fixing NICKEL chrome plated copper alloy Fancy concealed stop cock with sheet flance 20mm Jaquar make or equivalent. Confirming to IS 8931;1993 15mm nominal bore
105Providing and fixing NICKEL chrome plated copper alloy Fancy wall mixer with 115mm long bend pipe for connection to over head shower Jaquar make or equivalent. Confirming to IS 8931;1993Wall mixer with 115 mm long bend pipe for connection to over head shower.
106Providing and fixing NICKEL chrome plated copper alloy Fancy BOTTLE TRAP ECONOMY TYPE 32MM Jaquar make or equivalent. Confirming to IS 8931;1993
107Providing and fixing NICKEL chrome plated copper alloy Fancy waste coupling 32 mm with 190 mm long connection pipe wall flance Jaquar make or equivalent. Confirming to IS 8931;1993
108Providing & fixing soap dish chromium plated with brackets fixed to wooden cleats with CP brass screw
109Providing & fixing G.I. pipes complete with G.I. fittings including trenching & re-filling etc. (external work). 40 mm nominal bore
110Providing & fixing G.I. pipes complete with G.I. fittings including trenching & re-filling etc. (external work). 50 mm nominal bore
111Providing & fixing G.I. pipes complete with G.I. fittings including trenching & re-filling etc. (external work).80 mm nominal bore
112High pressure with P.V.C. floats: 15 mm nominal bore
113High pressure with P.V.C. floats: 20 mm nominal bore
114High pressure with P.V.C. floats: 25mm nominal bore
115Providing and fixing non-return valve of approved quality : 25 mm nominal bore
116Providing and fixing non-return valve of approved quality : 32 mm nominal bore
117Providing and fixing non-return valve of approved quality : 40 mm nominal bore
118Providing and fixing C.P. brass shower rose with 15 or 20 mm. Inlet:100 mm diameter
119Providing and placing on terrace roof of floor two (1st flor roof single piece rotational moulded polythene water storage tank having I S I mark and conforming to I S 12701; 1996.1000 lit. capacity
120Providing, laying and jointing glazed stone wear pipes grade “a” with stiff mixture of cement mortar in the proportion of 1:1 (1 cement :1 fine sand) including testing of joints etc. complete :100 mm diameter
121Providing, laying and jointing glazed stone wear pipes grade “a” with stiff mixture of cement mortar in the proportion of 1:1 (1 cement :1 fine sand) including testing of joints etc. complete :150 mm diameter
122Providing, laying and jointing glazed stone wear pipes grade “a” with stiff mixture of cement mortar in the proportion of 1:1 (1 cement :1 fine sand) including testing of joints etc. complete :230 mm diameter
123Providing and fixing square-mouth S.W. gully trap grade ‘A’ complete with c.i. grating brick masonry chamber and water tight C.I. cover with frame of 300 x 300 mm size (inside the weight of cover to be not less than 4.53 kg). And frame to be not less than 2.72 kg as per standard design :100 x 100 mm size P type
124Providing and fixing square-mouth S.W. gully trap grade ‘A’ complete with c.i. grating brick masonry chamber and water tight C.I. cover with frame of 300 x 300 mm size (inside the weight of cover to be not less than 4.53 kg). And frame to be not less than 2.72 kg as per standard design :150 x 100 mm size –P or S type
125Constructing brick masonry manhole or inspection chamber with second class bricks in cement mortar 1:5 (1 cement :5 fine sand) R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand ;4 graded stone aggregate 20mm nominal size foundation concrete 1:2:4 mix (1 cement ;2 coarse sand :4 graded stone agrregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cemetn and making channels in cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) neatly finished complete as per standard design.Inside size 90 x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455 x610mm internal dimensions total weight of cover ad frame to be not less than 38 kg. (weight of cover 23 kg. )
126Constructing brick masonry manhole or inspection chamber with second class bricks in cement mortar 1:5 (1 cement :5 fine sand) R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand ;4 graded stone aggregate 20mm nominal size foundation concrete 1:2:4 mix (1 cement ;2 coarse sand :4 graded stone agrregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cemetn and making channels in cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) neatly finished complete as per standard design.Inside size 90 x80 cm and 60 cm deep including C.I. cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 kg. (weight of cover 23 kg.)
127Constructing brick masonry manhole or inspection chamber with second class bricks in cement mortar 1:5 (1 cement :5 fine sand) R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand ;4 graded stone aggregate 20mm nominal size foundation concrete 1:2:4 mix (1 cement ;2 coarse sand :4 graded stone agrregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cemetn and making channels in cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) neatly finished complete as per standard design.Inside size 1.2m x 90 cm and 90cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter total weight of cover and frame to be not less than 116 kg. (weight of cover 58 kg).
128Constructing brick masonry manhole or inspection chamber with second class bricks in cement mortar 1:5 (1 cement :5 fine sand) R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand ;4 graded stone aggregate 20mm nominal size foundation concrete 1:2:4 mix (1 cement ;2 coarse sand :4 graded stone agrregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cemetn and making channels in cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) neatly finished complete as per standard design.Inside size 60 x 60cm and 60cm deep including C.I. cover with frame (light duty) 455x610mm internal diameter total weight of cover and frame to be not less than 38 kg. (weight of cover 23 kg).
129Replacement of M.S. foot rests in manholes including dismantling concrete blocks and fixing with 20 cm x 20 cm x 10 cm cement concretes including 1:3:6 (cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size):With 20mm x 20 mm square of round bar
130Making connection of drain or sewer line with existing manholes including braking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete: For pipe 100 to 150 mm dia
131Providing and fixing rigid PVC bend of required degree (of approved make) for S.W.R. drainage pipes of approved including lubricating.110 mm dia
132Providing and fixing rigid PVC bend (approved make ) for S.W.R. pipes including lubricating etc complete bend with door :100 mm dia
133Providing and fixing rigid PVC bend (approved make ) for S.W.R. pipes including lubricating etc complete bend with door :75 mm dia
134Providing and fixing single tee of rigid PVC (approved make) for S.W.R. pipes including lubricating etc. complete, without door:110 mm dia.
135Providing and fixing single tee of rigid PVC (approved make) for S.W.R. pipes including lubricating etc. complete, without door:75 mm dia.
136Providing and fixing nahani trap of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, without door :110 mm dia Each 128.00
137Providing and fixing nahani trap of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, without door :75 mm dia Each 118.00
138Providing and fixing R.P.V.C. vent cowl:110 mm dia
139Providing and fixing R.P.V.C. vent cowl:75 mm dia
140Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 pipe).15 mm outer dia CPVC pipe
141Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 pipe).20 mm outer dia CPVC pipe
142Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 pipe).25 mm outer dia CPVC pipe
143Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 pipe).32 mm outer dia CPVC pipe
144Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 pipe).40 mm outer dia CPVC pipe
145Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 pipe).50 mm outer dia CPVC pipe
146Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc.15 mm dia nominal outer dia pipes.
147Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc.20 mm dia nominal outer dia pipes.
148Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc.25 mm dia nominal outer dia pipes.
149Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc.32 mm dia nominal outer dia pipes.
150Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes confirming to IS: 15778 having thermal stability for hot and cold water supply includng all CPVC plain and brass threaded fittings CPVC solvent cement,trenching ,refilling and testing of joints complete as per firectionof the Engineer incharge.(External work (heavy duty SDR 11 pipe)32 mm nominal outer dia pipes
151Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes confirming to IS: 15778 having thermal stability for hot and cold water supply includng all CPVC plain and brass threaded fittings CPVC solvent cement,trenching ,refilling and testing of joints complete as per firectionof the Engineer incharge.(External work (heavy duty SDR 11 pipe)40 mm nominal outer dia pipes
152Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes confirming to IS: 15778 having thermal stability for hot and cold water supply includng all CPVC plain and brass threaded fittings CPVC solvent cement,trenching ,refilling and testing of joints complete as per firectionof the Engineer incharge.(External work (heavy duty SDR 11 pipe)50 mm nominal outer dia pipes
153Providing and fixing P.V.C.Rain water pipes of 160mm outer diameter and having wallthickness of 2.2to2.7mm confirming to I.S .135921992 including proper rain water receiving recess with P.V.C. plug,bend,necessary fittings ,such as,offsets,shoes,inluding fixing the pipe on wall using approved wooden cleatsprojecting 25mm to 40 mm from face of wall a fixing with clips of approved quality and number,filing the join t using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks,including necessarys caffolding and maintenance for 3yrs for any leakages or dislocations of pipes.All the P.V.C. fitting sand additional 2 piece socket clip s shall be go tapproved from engineer in charge etc. complete. [for Rain Water Pipes Vetical&horizontal)160 mm OD
154Providing and fixing 15cm rigid PVC Nahani trap including PVC grating,bend,connecting piece of UPVC pipe up to the outside face of wall ,making the good damaged surface anesting etc.complete(Prior approval of sample and brand by Ex.Engr.is necessary before use)
155Supply and fixing,testing commissioning of aquaguard Magna HD 25ltrRO + Uv water purifier and black comolete as per specification & direction of the engineer in charge
156Providing and fixing vertical storage type hot water heater fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug. Capacity 25 Litres Venus Model Magma 25GV
157Providing and fixing fully automatic Hand dryer Euronics Model-EH 26 NW or equivalent ,including all fittings complete in all respect.
158Providing and fixing Aerosol Perfume Dispenser Euronics Model-EA 24 or equivalent ,including all fittings complete in all respect.
159Providing and fixing Straight Grab Bar, 600 mm length and 35 mm dia made of antibacterial nylon. The item should have base plate support with SS screws (304 grade) & PVC wall plugs.
160Providing and fixing cast brass clean out plug with suitable insert keys for opening, male threaded joint with GI threaded socket caulked to CI soil pipe including cost of lead Joint.100 mm dia
161Providing and fixing cast brass clean out plug with suitable insert keys for opening, male threaded joint with GI threaded socket caulked to CI soil pipe including cost of lead Joint.150 mm dia
162Providing and fixing cast brass clean out plug with suitable insert keys for opening, male threaded joint with GI threaded socket caulked to CI soil pipe including cost of lead Joint.75 mm dia
163Providing, fixing, jointing & testing of uPVC agricultural (6kgf/cm2) grade pipes and fittings conforming to IS 4985 -2000 complete with solvent cement jointing with testing of pipes and making the joints leak proof. (For Pipes Buried in Toilets from Wash Basin etc to Main Drain) 50 mm NB (SP+WP)
164Providing, fixing, jointing & testing of uPVC agricultural (6kgf/cm2) grade pipes and fittings conforming to IS 4985 -2000 complete with solvent cement jointing with testing of pipes and making the joints leak proof. (For Pipes Buried in Toilets from Wash Basin etc to Main Drain) 40 mm NB (WP)
165Providing, fixing, jointing & testing of uPVC agricultural (6kgf/cm2) grade pipes and fittings conforming to IS 4985 -2000 complete with solvent cement jointing with testing of pipes and making the joints leak proof. (For Pipes Buried in Toilets from Wash Basin etc to Main Drain) 32 mm NB (WP)
166Providing and fixing forged brass single acting air release valve with screwed inlet 25 mm dia.
167Providing, fixing, jointing & testing of UPVC pipe Type-B for Soil, Waste upto 160mm dia. confirming to IS 13592 cut torequired lengths including all necessary fittings and specials such as as 45 or 90 deg. bends, Tee"s, Y"s, access pipe with solvent cement jointing. Setting the pipes in cement concrete M-15 as per specifications after testing of pipes. (For Pipes buried in flooring- Internal drainge )110 mm
168Providing, fixing, jointing & testing of UPVC pipe Type-B for Soil, Waste upto 160mm dia. confirming to IS 13592 cut torequired lengths including all necessary fittings and specials such as as 45 or 90 deg. bends, Tee"s, Y"s, access pipe with solvent cement jointing. Setting the pipes in cement concrete M-15 as per specifications after testing of pipes. (For Pipes buried in flooring- Internal drainge )75 mm
169Providing, fixing, jointing & testing of UPVC pipe Type-B for Soil, Waste upto 160mm dia. confirming to IS 13592 cut torequired lengths including all necessary fittings and specials such as as 45 or 90 deg. bends, Tee"s, Y"s, access pipe with solvent cement jointing. Setting the pipes in cement concrete M-15 as per specifications after testing of pipes. (For Pipes buried in flooring- Internal drainge )150 mm
170Providing & fixing in position 80mm NB "P" type trap of self cleaning type (inlet to "P" trap to be 100mm dia) including brass 125mm dia CP grating, drip seal jointing embeding in concrete etc. all complete.
171Providing, laying and jointing HDPE Double Wall Coil (DWC) SN-8 Grade pipes confirming to IS: 16098including all fittings wherever required e.g., tees, bends of any degree, couplings, adapters, plugs, unions etc. and jointing as manufacturer recommondation etc. including testing of joints etc. complete.(EXTERNAL SEWER)160 mm OD
172Providing, laying and jointing HDPE Double Wall Coil (DWC) SN-8 Grade pipes confirming to IS: 16098including all fittings wherever required e.g., tees, bends of any degree, couplings, adapters, plugs, unions etc. and jointing as manufacturer recommondation etc. including testing of joints etc. complete.(EXTERNAL SEWER)200 mm OD
173Providing, laying and jointing HDPE Double Wall Coil (DWC) SN-8 Grade pipes confirming to IS: 16098including all fittings wherever required e.g., tees, bends of any degree, couplings, adapters, plugs, unions etc. and jointing as manufacturer recommondation etc. including testing of joints etc. complete.(EXTERNAL SEWER)250 mm OD
174Providing & Fixing Heavy CI Grating at The Collection Point of Rainwater Pipe On Terrace of approved design. (Rain water Khurra)150 X 250 mm (Rain Water Outlet)
175Providing and constructing Brick building. Masonry catch basin of suitable size including excavation, cement concrete bedding 150 mm thick in cement mortar outside the Brick building. masonry (230 mm) in cement mortar 1:6 and benching from inside with 1:2:4 C.C. and plastering with cement mortar 1:3 from inside and outside and fixing air tight RCC covers of following sizes including curing etc suitable for following sizes of Catch Basin.450 X 450 mm
176Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface steel conduit( medium) withmodular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (a) Group A-- with Cat A Modular Accessories
177Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable insurface steel conduit( medium) with 2 way modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(a) with Cat A Modular accessories
178Wiring for 5A /15A power plug with 2 x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface steel conduit( medium) alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
179Wiring for 5A /15A power plug with 4 x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface steel conduit( medium) alongwith 2 Nos of4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
180Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface steel conduit( medium) of appropriate size as required.(b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit)
181Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface steel conduit( medium) of appropriate size as required. (c) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm Conduit)
182Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface steel conduit( medium) as required. (b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire
183Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface steel conduit( medium) as required. (c) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire
184Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface steel conduit ( medium)and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
185Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface PVC conduit( medium) with modular switch, modular plates,suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (a) Group A-- with Cat A Modular Accessories
186Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface PVC conduit( medium) with 2 way modular switch, modular plates,suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (a) with Cat A Modular accessories
187Wiring for 5A /15A power plug with 2 x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface PVC conduit( medium) alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
188Wiring for 5A /15A power plug with 4 x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface PVC conduit( medium) alongwith 2 Nos of4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
189Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface PVC conduit ( medium)of appropriate size as required. (b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit)
190Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the existing surfacerigid PVC conduit( medium)/ casing caping, as required. (b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire
191Supplying and fixing suitable size modular GI box with modular plate and coverin front on surface or in recess including providing and fixing 4 nos 3 pin 5/6 Amodular socket outlet and 4 nos 5/ 6 Amodular switch connection painting etc. as required. The scope of work includes alternate arrangement, if required as per site conditions, to provide switches and sockets seperately, above and below the table respectively.( For workstations) (a) Cat A
192Supplying and fixing suitable size modular PVC box with modular plate and coverin front on surface or in recess including providing and fixing 1 no 6 pin 15/16 Amodular socket outlet and 1 nos 15/ 16 Amodular switch connection painting etc. as required.( For workstations) (a) Cat A
193Supplying and fixing suitable size modular PVC box with modular plate and coverin front on surface or in recess including providing and fixing 2 no 6 pin 15/16 Amodular socket outlet and 2 nos 15/ 16 Amodular switch connection painting etc. as required.( For workstations) (a) Cat A
194Supplying and fixing suitable size modular GI box with modular plate and coverin front on surface or in recess including providing and fixing 2 no 6 pin 15/16 Amodular socket outlet and 2 nos 15/ 16 Amodular switch connection painting etc. as required.( For workstations) (a) Cat A
195Supplying and fixing suitable size modular PVC box with modular plate and coverin front on surface or in recess including providing and fixing required number of modular switches , connection painting etc. as required.( For group controlled points) (a) Cat A
196Installation, earthing, testing and commissioning of ceiling fan including wiring the down rodof standard length ( upto 30 cm) with 1.5 sq .mm FR PVC insulated copper conductor single core cableincluding providing and fixing phenolic laminated sheet cover on the fan boxetc. as required.
197Carriage of ceiling fan and regulator/ exhaust fan from store to site as required.
198Installation, earthing, testing and commissioning of exhaust fan upto 450 mm sweep in the existing opening including making the hole to suit the size of the above fan making good the damage connections testing commissioning etc as required
199Installation, earthing, testing and commissioning of exhaust fan upto 510 mm sweep in the existing opening including making the hole to suit the size of the above fan making good the damage connections testing commissioning etc as required
200Supplying installation testing and commissioning of surface/ recess mounting vertical type 415 V TPN,double door MCB DB of sheet steel dust protected duly phosphatised and powder painted inclusive of 200 A tinned copper busbar common neutral link earth bar din bar for mounting MCBs detachable gland knock out plate and with 100 A 10 KA MCCB as incomer interconnection between incomer MCCB and busbars of following ways (but without MCCB/MCBs as required)(c) 12 way with 100A MCCB as Incomer, double door,Cat A
201Supplying and fixing 6 A to 32 A,C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. (a) SP, Cat A
202Supplying and fixing 40 A,C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. (e) TPN, Cat A
203Supplying and fixing 63 A,C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. (e) TPN, Cat A
204Supplying and fixing SP blanking plate in the existing MCB DB complete as required
205Supplying and fixing 20 A 240 V SPN industrial type socket outlet with 2 pole and earth metal enclosed plug top alon with 20 A, C seriesSP MCB in sheet steel enclosure in surface or in recess with chained metal cover for the socket outlet and complete with connections testing and commissioning etc. as required" (a) Cat A
206Providing and fixing M.V. Danger Notice plate of 200mm x 150 mm made of mild steel atleast 2 m thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required
207Providing and fixing HT Danger Notice plate of 250mm x 200 mm made of mild steel atleast 2 m thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required
208Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with CI/RCC coverhaving locking/Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation ofpit of size 1.0x1.0x 3.0 mtrs(min) and disposal of excavated soil.c)Watering GI pipe, 20mm, Class B,with funnel as per specs. d)Charcoal/salt as per specs ( paid seperately). e) Refilling the pit of size 1.0x1.0x 3.0 mtrs(min) with soft black agriculture soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe.g)watering arrangement(plumbing will be paid seperately).(a) In soily strata
209Supply of Back fill Compound/ Groung resistance enhancement powder conforming to the enclosed specifications.
210Constructing aspecial masonryinspection chamber for earthing system as per the enclosed drawing and specifications. Thesquare chamber( 860 x860mm) shall be constructed with brick masonry of 230 mm on a solid base of 75mm rubble packing and 75mm PCC. The floor level shall be finished with 50mm cement concrete. The inside wall of the chamber shall be plastered with 12mm plaster finish. A removable CI/RCC cover of size 400x 400mm ona angle box frame of 35x35x5mm shall be provided with locking arrangements/ lifting lugs. The scope of work includes all material labour etc complete as required.
211Supplying and drawing/fixing jelly filled unarmoured telephone cable with0.5 sq.mm dia. tinned copper conductor, ITD/DOT approved, with GI saddles on wal or in the existing surface/recesed steel/PVC conduit having folowing pair(s), complete as required.(a) 5 Pair
212Supplying and drawing/fixing jelly filled outdoor type armoured telephone cable with0.5 sq.mm dia. tinned copper conductor, ITD/DOT approved, with GI saddles on wal or in the existing surface/recesed steel/PVC conduit having folowing pair(s), complete as required.(d) 50 Pair
213Supplying and drawing/fixing jelly filled outdoor type armoured telephone cable with0.5 sq.mm dia. tinned copper conductor, ITD/DOT approved, with GI saddles on wal or in the existing surface/recesed steel/PVC conduit having folowing pair(s), complete as required. (e) 100 Pair
214Supplying, installing, testing and commissioning of Junction Box, ITD/DOT approved, indoor type with wall mounting/concealed facility having front door with lock along with aluminium frame for mounting disconnection type Krone modules, complete cabinet fabricated from 18 SWG CRCA sheet with powder coating in appropriate manner and suitable for following capacity of pairs, including Krone makemodules, crimping and terminations, etc. complete as required.(a) 10 Pair
215Supplying, installing, testing and commissioning of Junction Box, ITD/DOT approved, indoor type with wall mounting/concealed facility having front door with lock along with aluminium frame for mounting disconnection type Krone modules, complete cabinet fabricated from 18 SWG CRCA sheet with powder coating in appropriate manner and suitable for following capacity of pairs, including Krone makemodules, crimping and terminations, etc. complete as required.(c) 50 Pair
216Supplying, installing, testing and commissioning of Junction Box, ITD/DOT approved, indoor type with wall mounting/concealed facility having front door with lock along with aluminium frame for mounting disconnection type Krone modules, complete cabinet fabricated from 18 SWG CRCA sheet with powder coating in appropriate manner and suitable for following capacity of pairs, including Krone makemodules, crimping and terminations, etc. complete as required.(d) 100 Pair
217Supplying, erecting and commissioning of Discoonection type Krone Module, ITD.DOT approved, having capacity of 10 pairs with silver plated terminal contacts, complete as required.
218Supplying and drawing of Cat - 6 UTP, 4 pair annealed tinned copper conductor PVC insulated, PVC sheathed, unarmoured data cable in existing surface/recessed steel/PVC conduit of appropriate size including connection, etc. complete as required(a) Cat 6
219Supplying, installation and testing of suitable size modular GI box , modular plate and cover complete with RJ-45 connector(modular LAN socket TX1000/ CAT6) including concealed metal box/surface GI/PVC Box, modular plate, punching, identifying, complete as required. CAT A
220Supplying, installation and testing of suitable size modular GI box , modular plate and cover complete with RJ-11 connector(modular telephone socket) including concealed metal box/surface GI/PVC Box, modular plate, punching, identifying, complete as required. CAT A
221Supplying, installation and testing of suitable size modular GI box , modular plate and cover complete with modular TV socket including concealed metal box/surface GI/PVC Box, modular plate, punching, identifying, complete as required. CAT A
222Supply of4 core unarmoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.4 Core 4 sq.mm
223Supply of4 core unarmoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.4 Core 10 sq.mm
224Supply of4 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI markconforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 4 Core 6 sq.mm
225Supply of4 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI markconforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.4 Core 10 sq.mm
226Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.(1) 3 x 1.5/2.5 Sq. mm.
227Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.(1) 4 x 1.5/2.5 Sq. mm.
228Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.(2) 4 x 4 Sq. mm.
229Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.(5) 4 x 16 Sq. mm.
230Supplying and Installing following size perforatedtype 16 SWG, M.S.cable tray of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required. 100mm width x 50mm depth
231Supplying and Installing following size perforatedtype 16 SWG, M.S.cable tray of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required.150mm width x 50mm depth
232Supplying and Installing following size perforatedtype 16 SWG, M.S.cable tray of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required. 200mm width x 50mm depth
233Supplying and Installing following size perforatedtype 16 SWG, M.S.cable tray of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required. 300mm width x 50mm depth
234Supplying and erecting LED square / circular Max. 11 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
235Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
236Supplying and erecting LED Panel Light(600mm X 600mm) Max. 30 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips plete with 3 years warranty.
237Supplying and erecting integrated LED Highbay Fitting 100W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of Min. 15000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L50B50 , including driver complete with 3 Year warranty as per specification No FG-ODF/FLS2.
238Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 ears warranty
239Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
240Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. withverheating protection with 2 years warranty.
241Supply of following rating MCCB in Sheet Steel Enclosure with extended cable end box for Incoming Cable.125A FP MCCB ,25 kA breaking capacity
242Supply of following rating MCCB in Sheet Steel Enclosure with extended cable end box for Incoming Cable.63A FP MCB+RCCB 300mA
243Supply of following rating MCCB in Sheet Steel Enclosure with extended cable end box for Incoming Cable.40A FP MCB 10kA
244Supply, Installation Testing and Commissioning of IP 20 Rated, 3D Printed Pendant Luminaire suitable for E27 lamp. The Housing material of the shade should be recyclable 100% Virgin Polycarbonate. The pendant shade should be available with choice of essential colors, primary colors and shiny metallic colors with a possibility of printing Logo through 3D printing process. The pendant shade should have flexibility of having textures to provide a improved aesthetic appeal. In terms of design , Luminaire should have a modular assembly and the shade should be replaceable without tooling and while being able to re-use all other luminaire parts. The Pendant shade should be within size limit of 250 mm x 250 mm and should be tested in conformity with the essential requirements of the European Directives and harmonized standards: EN 60598-1: 2015 and EN 50581:2012. Similar to Philips 3D printed luminaire
245Supply of LED exit signage of Box size in mm 325 x 425 x 365
246Supplying, installing, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR Capacity having ISEER minimum 3.50 to maximum 3.99 suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hiwall / floor mounting type complete with refrigerant R410 A/R32 and copper condenser at position. specification no. APAC/ SAC
247Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 12 mm complete.
248Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 16 mm complete.
249Supply, installation, testing and commissioning cordless remote contol having colour LCD panel, real time clock, temperature limitation (16 to 30 degree Cent.), functions like filter clean reminder timer suitable to communicate with wired controller complete.
250Supplying, installing, testing and commissioning FR, XLPE armouredcable 2 core1.5 sq.mm. copper conductorcomplete erected on wall/ ceiling complete as per specification no. CB-LT/CU
251Supply, Installation Testing & Commissioning of Dual Tone Metal Grill Ceiling Mounted Speaker with all recquisite mouting accessories to mount the speaker on False Ceiling / True Ceiling.6 Watts with Tapping of 6/3/1.5W Brands: Bosch/Ateis/Honeywell
252Supply Installation, Testing and comissioning of 6 Zone Main PA Console Expandable upto 12 zones, Complete with suitable rack arrangement to house the entire PA system components. The system shall be equipped with relaying inbuilt automated messages in case of an emergency. Note:- Vendor to calculate Rack size based on the no amplifiers, message manager and controller with call station etc.Brands: Bosch/Ateis/Honeywell
253Supply Installation, Testing and comissioning of Booster (Audio) Amplifiers sutaible to accommodate all above speakers, and Shall be connected to Main PA consoleBrands: Bosch/Ateis/Honeywell 250 Watt
254Supply, installation, Testing and Commissioning of Call Station With 6 Zone Selection Switch and microphone and accessories required to achive desired functionality. Complete with required accessories and cables Brands: Bosch/Ateis/Honeywell
255Supply, Installation Testing & Commissioning of Volume Control, Shall capable to override incase of fire Emergency.Brands: Sony/Samsung/Bosch
256Supply installation of 2 Core x 1.5 mm2, Multistranded AT Copper, FRLS Armoured cable, BLUE in Colour. The cable shall belaid on surface with GI saddle-spacers every 0.3 meters. Complete with GI Junction Box, lugs, cable compression glands, cable tags and Ferruling.Brands: Bosch/Ateis/Honeywell
257Supplying and erecting ISI mark GI pipe 75/80 mm dia ‘C” class position with accessories complete. Specification no. CW-PLB/GP.
258Supplying and erecting ISI mark GI pipe 100 mm dia ‘C” class position with accessories complete. Specification no. CW-PLB/GP.
259Supplying & erecting cast iron double flange butterfly valve of size 100 mm dia. complete as per specification no. FF-VL/BFV
260Supplying and erecting cast iron double flange NRV of size 100 mm dia complete as per specification no. FF-VL/NRV
261Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification no.FF-VL/HV
262Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) fitted with necessary accessories complete as per specification no. FF-FFA/HV
263Supplying fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
264Supplying & erecting gun metal branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FF-FFA/NZ
265Supplying and erecting 20/25mm dia gun metal air release cock,with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
266Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FFFFA/PG
267Supplying and installing pressure switch with 12/15 mm dia isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
268Supplying and erecting one no. brass orifice plate having 6 mm.thickness, 140 mm outer dia and required/proper diameter of inner hole at every single outlet hydrant valve as per specification no.FF-FFA/OP
269High pressure with P.V.C. floats:25mm nominal bore
270Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete
271Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall..
272Supplying and erecting D.C.P. type fire extinguisher 9 kg capacity cartridge type with Gun Metal cap 150 gram CO2 gas cartridge, powder and brackets conforming to IS 2171-1985 and complete erected with necessary clamps made from 50x6 mm M.S.flat with nuts & bolts grouted in wall complete.
273Supplying, installing, testing & commissioning of electrical motor driven, Positive Suction type Booster Pump, Monoblock type of capacity 900 LPM at 35 Mtrs. The pump shall be coupled to Squirrel Cage Induction TEFC motor of suitable HP with speed of 2900 RPM. Complete set shall be mounted on common base frame. The rate shall be inclusive of foundation bolts,Vibration Isolators and all other necessary accessories, complete in all respects.
274Supply, Erection of emergency Start / Stop Push Button station weather proof type for Booster pump at terrace level. ( Also Panel should be compatible for BMS Connectivity like Level switch to be provided for fire ug, All Pumps On / Off Command, On / Off Status, Trip Status to be Monitor on BMS and for the same Potentialfree Contacts to be privided in starter Panel.) NOTE 2 sets of push buttons to be provided one in BMS /FA room and other in security room near main gate.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail