Tender For Repair And Maintenance Of Summer Appliances At Dscc Ayodhya Nagar Bhopal, bhopal-Madhya Pradesh

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Summer Appliances At Dscc Ayodhya Nagar Bhopal. Submission Date for this Tender is 26-06-2023. Air Conditioner Tenders in bhopal Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

37903581
Corrigendum : Tender For Repair And Maintenance Of Summer Appliances At Dscc Ayodhya Nagar Bhopal
Open Tender
Indian
Madhya Pradesh
bhopal
26-06-2023

Tender Details

Repair And Maintenance Of Summer Appliances At Dscc Ayodhya Nagar Bhopal

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 22000.0 /-
Tender Value
INR 11 Lakhs /-

BOQ Items

Name of Work: REPAIR AND MAINTENANCE OF SUMMER APPLIANCES AT DSCC AYODHYA NAGAR BHOPAL
Sl. No. Item Description
1M & L for servicing of window type AC of capacity 1.5/2 TR of any make including cleaning of filter on front side by removing dust, cleaning the condenser including fins, blower fan motor and checking and testing of all parts for its serviceability, oiling/greasing to condenser cum blower fan motors, replacing worn out rubber, bushes/rubber packing, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc and reassembling of complete AC including testing for smooth functioning complete all as specified and directed by Engineer-in-Charge. Note : Refrigerant required for topping (R22 / 134) shall be measured and paid for separately as "supply only rates" under respective item.
2Replacement of following unserviceable item in Split type AC 1.5/2 TR :-
3Supply only Blade for condensing fan motor
4Supply onlyRunning Capacitor 45 Mfd
5Supply onlyRunning Capacitor 6 Mfd
6S & F in repairs running capacitor (ISI Marked), 36 Mfd suitable for AC of capacity 1.5/2 TR. complete all as specified and directed by Engineer-in-Charge.
7S & F in repairs starting capacitor, 100-120 Mfd suitable for AC of capacity 1.5/2 TR. complete all as specified and directed by Engineer-in-Charge.
8S&F in repairs PVC fan blade suitable for condenser of split type AC of 1.5/2 TR capacity.
9S&F in repairs cooling fan motor of split type AC of 1/30 or 1/35 HP capacity of make Carrier/ Hitachi / Voltage / Blue star, all as directed by Engineer-in-Charge.
10S&F in repairs cooling blower fan motor of split type AC of 1/30 or 1/20 HP capacity of make Carrier/ Hitachi / Voltage / Blue star, all as directed by Engineer-in-Charge.
11S&F Foam type insulating flexible pipe & air tight outer tapping fitted on ACs of any capacity for suction / discharge copper tubes.
12S&F in repairs wall mounted indoor Voltage Stabilizer automatic operation single phase and designed for input variation between 170 V to 250 Volt with output voltage stabilized at 230 V with accuracy of +2.5% and of capacity 2 KVA.
13S&F in repairs wall mounted indoor Voltage Stabilizer automatic operation single phase and designed for input variation between 170 V to 250 Volt with output voltage stabilized at 230 V with accuracy of +2.5% and of capacity 4 KVA.
14Supply & fixing single pole and neutral enclosure with a two pin and socket complete with one single pole MCB 240 volts, 20 Amps.
15S&F in repairsRotary type Compressor (Sealed Unit) of window / split type AC 1.5 TR capacity, single phase, 220 volt of make Kirloskar / Tecumseh / Carrier includingnecessary modification of foudation as required to suit the comptessor, vacumisation, pressure testing, leakage rectification including gas charging R-22/134 & testing complete to the entire satisfaction ofEngr-in-charge.
16S&F in repairsRotary type Compressor (Sealed Unit) of window / split type AC 02 TR capacity, single phase, 220 volt of make Kirloskar / Tecumseh / Carrier includingnecessary modification of foudation as required to suit the comptessor, vacumisation, pressure testing, leakage rectification including gas charging R-22/134 & testing complete to the entire satisfaction ofEngr-in-charge.
17S&F in repairsRotary type Compressor (Sealed Unit) of refrigerator 165/175 ltr capacity, single phase, 220 volt of make Kirloskar / Tecumseh / Carrier includingnecessary modification of foudation as required to suit the comptessor, vacumisation, pressure testing, leakage rectification including gas charging R-22/134 & testing complete all as specified and directed by Engineer-in-Charge.
18Supply and top up of Refrigerant gas R 22incompany sealed cylender of capacity complete all as specified and directed by Engineer-in-Charge.
19Supply and top up of Refrigerant gas R 134incompany sealed cylinder of capacity complete all as specified and directed by Engineer-in-Charge.
20Supply and fix PCB for split type AC of capacity 1.5 TR complete all as specified and directed by Engineer-in-Charge. .make as per site requirment
21Supply and fix PCB for split type AC of capacity 2 TR complete all as specified and directed by Engineer-in-Charge. .make as per site requirment
22Supply & fix in repair wall mount stand forsplit ac outdoor unit shall be fixed on wall with standard bracket or fixed on roof /floor with proper MS stand.
23M&L for cleaning after takingdown complete body including fitting and fixture of desert cooler of capacity 4000/5000 cum/hours of any make with wire including removal of all sludge, loose paint dirt etc and preparationand cleaning of surface for painting and applying two coats of synthetic enamelspray paint inside and out side surfaces and applying two coats rubber seal paint inside the water tank, and rewriting of MES No. etc. complete all as specified and directed by Engineer-in-Charge.
24S&F in repairs PVC flexible pipe 16mm outer dia complete with PVC elbow etc.
25S&F in repairs selector switches three way 230 Volts single phase of standard quality fixed in desert coolers.
26S&F in repairs wood wool pad (set of three), minimum weight 0.8 Kg, fixed in side panels of desert coolers including GI wiremesh of 20 Gauge wire and mesh size 100 x 100 mm complete all as directed .
27S&Freplacement piano type switch single pole 230 volt flush type 5 Amps
28S&F in repairs capacitor 4 MFD for fan motors of desert coolers.
29S& F in repairs Sub mersible pump 230 volts suitable for desert cooler of capacity 4000/5000 including necessary wiring complete all as directed.
30S & F in repairs side shutter (set of three) made out from 24 guage thick galvanized iron sheet suitable for 4000/5000 cum/hrs capacity desert coolers complete all as directed.
31S&F in repairs float valve high pressure of PTMT with epoxy coated aluminum rod and high density plastic ball, screwed for 15mm bore iron pipe, weight not less than 142gm/each. Complete all as directed.
32S & F in repairs Aluminium fan blade for fan motor of desert cooler 300 mm sweep.
33S & F in repairs PVC, 3 way distributor suitable for 15 mm pipe with nut/ screws all as directed.
34S & F in repairs desert cooler body of size 60x55x65 cm made out of 20 gauge GI sheet & water storage tank of soze 65x55x20 cm deep made out of 18 gauge GI sheet including front grills & three side shutters duly fitted with wood pads & duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer (inside & outside) all as directed by Engr-in-charge.
35S & F in repair desert cooler fan motor 3 speed copper winding ISI mark including suitable leg set of three including nut bolt washer all as directed.
36S & F wooden scantling second class hard wood of size 50X50 mm and making frame and fix with screw and nail for supporting to desert cooler.
37S & F ply wood with commercial face of 5 ply 6mmthick BWR grade for packing of AC and Disert cooler all as directed.
38M&L for sub main wiring with two runs of 4 sqmm single core PVC insulated but unsheathed FRLS copper conductor 1100V drawn through and including rigid heavy duty PVCconduit 25 mm dia with conduit accessories including 2.5 sqmm PVC insulated but unsheathed FRLS copper conductor used as earth wire all as directed by EIC
39Supply and lay PVC pipe20 mm dia with fittings in repairfixed on wall / ceiling.
40M&L for complete servicing of AHU unit of various capacity installed in DSCC Bhopal including replacement of defective parts as under after removing and refixing of insulations etc and testing comissioning of plant after replacement of spares completed all as specified and directed by Engineer in Charge
41Supply and fixingfan belts of AHU of size B-78 (Make: Dunlop,Fanner) as per existing size after removing the defective worn out fan belt.
42Supply and fixingfan belts of AHU of size B-90 (Make: Dunlop,Fanner) as per existing size after removing the defective worn out fan belt.
43Material & labour for filling Refrigerant R134a for top up (62 kg cylinder) for chillercomplete all as specified and as directed.
44Repair and replacement of cooling tower draft eliminator block of dimension 600 mm X 150 mm X 150 mm- 300 Nos (quantity) and 3 cooling tower fans blade 3 Nos complete all as specified and as directed.
45M&L for repair and rewinding of blower motor of capacity 7.5 HP/5.5 after taking out from its existing location, transporting to work shop, removing defective burnt wiring, rewinding of motor with new copper wire of suitable gauge including replacement of insulation paper, baking, heating , varnishing of winding, replacement of bearing, any machining and lath work as required, replacement of hardware as required etc and refixing it in existing location, testing comissioning complete up to the satisfaction of engineer in charge.
46Supply and fixing in replacement relay contactor, 3 Pole power contractor type MNX ,
47Supply and fixing in replacement relay contactor,4 Pole power contractor type MCX,
48Supply only temperature sensor of evaporator entering, condenser entering or evaporation leaving discharge temperature for chiller No. 3, Make: OEM
49Supply & fixing MCCBs for Motor back-up Protection TYPE 440 volt AC, 50 Hz, 3 pole,rupturing capacity 35 KA of capacity 63 Amps.
50All as per Item No.46.00 but 250 Amps 36 ka
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail