Tender For Repairs Maintenance Of Ac Plant Summer Appliances Like Split Window Acs Water Cooler Refrigerator Voltage Stabilizer And Connected Works Under Age Em Ii Of Ge Nw Vasco, vasco-Goa

Military Engineer Services-MES has published Tender For Repairs Maintenance Of Ac Plant Summer Appliances Like Split Window Acs Water Cooler Refrigerator Voltage Stabilizer And Connected Works Under Age Em Ii Of Ge Nw Vasco. Submission Date for this Tender is 15-06-2023. Voltage Stabiliser Tenders in vasco Goa. Bidders can get complete Tender details and download the document.




Tender Notice

37887069
Tender For Repairs Maintenance Of Ac Plant Summer Appliances Like Split Window Acs Water Cooler Refrigerator Voltage Stabilizer And Connected Works Under Age Em Ii Of Ge Nw Vasco
Open Tender
Indian
Goa
vasco
15-06-2023

Tender Details

Repairs Maintenance Of Ac Plant Summer Appliances Like Split Window Acs Water Cooler Refrigerator Voltage Stabilizer And Connected Works Under Age Em Ii Of Ge Nw Vasco 8533/E8

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

NAME OF WORK : REPAIRS / MAINTENANCEOF AC PLANT, SUMMER APPLIANCES LIKE SPLIT / WINDOW AC"s WATER COOLER REFRIGERATOR, VOLTAGE STABILIZER AND CONNECTED WORKS UNDER AGE E/M-II OF GE (NW) VASCO. (Tender ID No. 2023_MES_598913_1)
Sl. No. Item Description
1SPLIT TYPE AC Taking down carefully the unserviceble rotary / hermetically sealed compressor unit from split type AC 1.5 ton capacity and supply and fix new rokery hevenitically sealed factory made compersor of capacity suitable capacity from the authorised dealer, and testing commissioning complete all as specified and as directed.
2All as per Srl item No. 01 above but 2 Ton capacity as directed.
3Charging of refreigerentgas with required quantity, after testing the system against leakage & putting the split type AC of 1.5 / 2.0 Ton capacity in perfect working condition complete all as specified and as directed.
4Servicing of split type AC of any capacity and make, washing condensor, cooling unit, cleaning of air filter incl testing and replacement of spares / components as required complete all as specified and as directed. (i)Spares will be measured & paid as supply only items here in after (ii)Gas charging etc will be measured & paid separately.
5Supply only running capacitor 45 MFD for split type AC of suitable capacity complete all as specified and as directed.
6Supply only outdoor unit of split AC, 230 volt comprising of condensor coil, fan motor with blade 1.5ton capacity complete all as specified and as directed.
7Supply only indoor unit of split AC, 230 volt comprising of cooling coil, blower, remote sensor unit with remote 1.5 ton capacity complete all as specified and as directed.
8Replacement of Air filter made of PVC / Nylon fiber suitable for any split type AC complete all as specified and as directed.
9Replacement of complete wiring kit of suitable make and model of split type AC of any capacity complete all as specified and as directed.
10Replacement of condenser fan blade made out of aluminium/plastic for split type AC of suitable capacity of make as approved complete all as specified and as directed.
11Replacement of blower made of aluminium / plastic for split type AC of suitable capacity ofmake as approved complete all as specified and as directed.
12Replacement of starting capacitor 120/150 MFD complete all as specified and as directed.
13Replacement of starting relay suitable for split type AC complete all as specified and as directed.
14Supply only copper tubing (two copper tubings with insulation tube) as per existing size for split AC any capacity 230 volt complete all as specified and as directed.
15Supply only Printed circuit board (PCB) of Window / Split Acs 1.5/2.0 ton complete all as specified and as directed.
16Taking down of old unservicableair conditioner and supply and install new portable air conditionerwith Non-Inverter Compressor: Smart & Elegant Design, single phase 230 V 50 Hz 100% Inner Grooved Copper Tubes, Capacity: 1.0 ton suitable for small / medium size rooms (Up to 100 square feet) refrigerant: R-410 Refrigerant has been used in this AC which is environment friendly 360° rotating strong caster wheels to bear load of the AC and makes it easy to move with elegant design with Top Throw, Auto Swing & Auto Restart, Easy Installation, Self Diagnosis Function with Remote Control, LED Display,free standing with cooling power 3.45 KW wattage with exhaust pipe and window assembly panel of Make:- Havells/ Lloyd 2020 Model, LP12B01TP, White or equvialent in Voltas, Bluestar, Carrier, O General etc complete all as specified and as directed.
17WATER COOLERS Disconnection old unserviceable water cooler off capacity and supply & install new Aqua Clear Stainless SteelWater Cooler of capacity 60/80 ltrswith in built RO of storing capacity, of 60 Ltrs single phase 230 V, 50 Hz power consumption of 800 Watt to 1000 watt RO unit should have the Treated Water Flow of 1 m3/hr and Recovery : 55- 60%, Feed Water TDS should be 900 PPM (Max). Note:- Old unserviceable water cooler of any capacity will be shifted to AGE E/M-II yard.
18Taking down carefully the old unservicable compressor unit from the water cooler supply and fix new hermitically sealed compressor of suitable size & capacity from the authorised dealer and testing the compressor after refixing, of the following model :-
19Kirloskar -4440
20Tecumseh -AW 1000
21Charging of refrigerent gas with required quantity, after flushing out and testing the system against leakage etc and of connected works including replacement of copper capillary tube and putting the water cooler in perfect working condition and testing the same after re-installation complete all as specified and as directed of following Capacities:
22Cleaning, checking, servicing of water cooler of any capacity and re-assembling connecting complete all as specified and as directed. (i) Leakage testing of Gas and Gas charging will be measured and paid separately. (ii) Spares will be measured and paid separately as supplied only items.
2340/80/100/120/150 Ltr cap
24Supply only starting relay complete with over load protector suitable for Kirloskar/ Tecumsah compressor complete all as specified and as directed.
25Supply only starting capacitor 40-60 MFD
26Supply only starting capacitor80 - 100 MFD
27Supply only starting capacitor 25 MFD
28Supply only running capacitor 10 MFD
29Supply only condenser fan motor single phase, with blade, capacity 1/35 HP including mounting clamps, bushes, nuts and bolts complete all as specified and as directed.
30Supply only Srl item No. 25above but capacity 1/10HP
31Supply only thermostat suitable for any type of water cooler
32Cleaning of water cooler tanks with potassium permanganet solution after removing all dust/mud particles complete all as specified and as directed.
33Repairing of water cooler storage tanks leakages by soldering / brazing work complete all as specified and as directed.
34Supply only liquid line filter of make and size as approved by GE complete all as specified and as directed.
35Supply only PVC float valve 15mm bore with PVC heavy duty ball and rod, complete all as specified and as directed.
36Supply only brass chromium plated push cock of 15mm bore (as per sample) with brass flex nipple complete all as specified and as directed.
37Supply only PVC drain pipe 32mm dia, 1300 mm long flexible pipe complete all as specified and as directed.
38M&L spray painting of water cooler of any capacity after scrapping old painted surface and applying one coat of synthetic enamel paint including writing serial No/MES No & SM No (Size of letter 20mm) on the front of the Machine, with white paint complete all as specified and as directed.
39REFRIGERATORS Taking out carefully Old un-serviceable compressor unit from the refrigerator body and S&F new factory made rotary/ hermetically sealed compressor unit of existing capacity from the authorised dealer and testing the compressor after refixing complete all as specified and as directed of 165 ltrs capacity Refrigerator
40Cleaning, checking, servicing of Refrigerator of any capacity and re-assembling connecting complete all as specified and as directed. (i) Leakage testing of Gas and Gas charging will be measured and paid separately. (ii) Spares will be measured and paid separately as supplied only items.
41Charging of refrigerant gas with required quantity after flushing out the system, testing the system against leakage and putting the refrigerator in working condition and testing after repair complete all as specified and as directed of165 ltrs Refrigerator
42Supply only liquid line filter for refreigerators of any type and cap of approved make complete all as specified and as directed.
43Supply only starting relay suitable for any type and cap of Refrigerators complete all as specified and as directed.
44Supply only thermostat switch with knob for refrigerator.
45Supply only bulb screw type 15 watts suitable for any type of refrigerators
46Supply only evaporation fan motor single phase, 230 volts, AC for any make and capacity of refrigerators including fan blades complete all as specified and as directed.
47Supply only freezer assembly suitable for any capacity and make of Refrigerators complete all as specified and as directed.
48Supply only condenser coil suitable for refrigerators of any capacity complete all as specified and as directed.
49Supply only vegetable tray, egg tray, water tray etc complete all as specified and as directed.
50VOLTAGE STABLIZER Rewinding of burnt transformer using super enamel copper wire of existing size as directed by EIC, for the following capacity of voltage Stablizers:
515 KVA Cap of any make
524 KVA Cap of any make
53Replacement of cut off relay of the following cap of voltage stablizers Make- Dunmeg or equivalent as approved by GE
545 KVA Cap of voltage stablizer
554 KVA Cap of voltage stablizer
56Replacement of automatic circuit complete of the following capacity of the voltage stablizer:
575 KVA Cap
584 KVA Cap
59Replacement of high/low cut off with time delay circuit of the following capacity of the voltage stablizer:
605 KVA Cap
614 KVA Cap
62Replacement of tigger transformer for the following capacities of the voltage stablizer:
635 KVA Cap
644 KVA Cap
65Replacement of volt meter AC, 230 volt of any capacity and size suitable for voltage stablizers as directed by EIC.
66Replacement of indicator bulb suitable for voltage stabilizers of approved make all as directed by EIC.
67Taking down old unserviceable Split type air conditioners ofCapacity 2.0 Tr comprising of indoor & outdoor units complete and suppy & install new Split air conditioner comprising of indoor & outdoor units complete with cordless remote control unit with cooling function of capacity 2.0 TR. Note:- The old split air conditioner comprising of indoor & outdoor units will be deposited to MES store yard of AGE E/M-II.
68Taking down of old unserviceable wall mounted stablizers and supply & installation of new Voltage stabliser of 5 KVA capacity automatic voltage stabilizer, wall mounted with input corrected range of 140 Volts to 280 Volts and output range voltage 225 Volts +/- 11% with digital display features of high and low out of range voltage shut down and time relay of 2 to 3 Mins on initial start Capacity – 5 KVA.
69M & L for sub main wiring with6 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor stranded cable with and including continuous earth wire of size 4.0 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor stranded cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories / fittings etc and connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified and as directed. Note :- 2 Runs of 6sqmm copper conductor cable and 1 Run of 4sqmm copper conductor cable with 1 Run PVC conduit 25mm dia will be measured as one RM unit
70Supply & fixing Sheet Metal Enclosures with one single pole MCB of 20 Amps capacity 240 volts "B" series 10KA and making connections complete all as specified and as directed.
71S&F (in repairs)MCCB, TPN, 100 Amps, Icu=16 KA, 415 volts, 50 hz, AC,with Adjustable Thermalrelease, Fixed magnetic type suitable releasein duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections complete all as specified and as directed.
72S&F in repairs MCCB, TPN, 160 Amps, Icu=35 KA, 415 volts, 50 hz, AC,with Adjustable Thermalrelease, Fixed magnetic type suitable release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections complete all as specified and directed.
73S&F in repairsMCCB, FP, 200 Amps, Icu=35 KA, 415 volts, 50 hz, AC,with Adjustable Thermalrelease, Fixed magnetic type suitable releaseduly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections complete all as specified and asdirected.
74Servicing and testing of Water Cooled Package Air Conditioners, comprising of Hermetic / Semi Hermetically sealed Scroll Compressors with microprocessor based control, including copper refrigerant piping, electrical interlockingbetween indoor units and condenser water pump motor, cooling tower motor etc, suitable for operation on R - 407C or any ecofriendlyrefrigerants, capacity not less then 3 x 15 TR (2 Working +1 No 50% stand by) i.e. one 15.0 TR standbyas per air conditioning data sheet enclosed as Appendix "A" with all equipment and accessories complete and comprisingthe following :- (a) Three Nos Package type air conditioning unit fully microprocessor controlled each of minimum 15.0 TR capacity complete and comprising of the following :-
75(i) Hermetically sealed Scroll type compressor with inbuilt motor of matching capacity, electrically operated on three phase 415 volts, 50 Hz AC supply complete with suction and discharge shut of valves, automatic capacity control with thermostats and solenoid valves, built in suctionstrainer, oil pump, hot gas muffler, oil pressure safety switch etc all as specified. (ii) Three Nos guage panel complete with HP/LP cut outs. oil switch, suction, discharge and oil pressure guage. (iii) Cooling coils of copper tube with aluminium fins. (iv) Filters, filter plenum and by pass dampers (03 Nos lots) with 90% efficiency to 20 microns. (vi) In built Blowers for weather makers complete (vii) Expansion valves and pilot solenoid valves.
76(viii) Three sets of spring antivibrationpads and suitable foundation as per manufacturer"s instructions for installation of the above package units. (ix) Necessary copper piping for liquid line complete with fittings valves etc. (x) First charge of ecofriendly refrigerant gas like R407C and oil for the complete plant. (xi) One set of flow switch in condenser water line (b) One lot of air distribution system from Package units to the space to be air conditioned and provision of return air plenum as per IS- 665 comprising of class VIII galvanized sheet with suitable supporting arrangements and bracing, supply / return / fresh air grills on wooden framework duly painted / finished to match with the existing ceiling, fire damper fusible link operated
77(c) Design and provision of hollow GI duct suitably insulated and weather protected from outside plant room to inside air conditioned room of suitable size and thickness duly supported on steel structure from AC Plant room to the rooms to be air conditioned for continuous supply and return air ductswith Plenum chamber and Canvas cloth joint.
78(d) Necessary provision of FRP cooling tower with fan and fan motor working on 415 V AC 3 phase supply of suitable capacity along with water pumps of suitable capacity electrically operated, 3 phase 415 Volts, monoblock type- 02 Nos (Minimum capacity 5 HP), circulating water pipe line made up of ERW steel pipe heavy grade with all fittings and fixtures of suitable size and length duly painted on the outer surface area to the unit including necessary supports / laying underground as per OEM specifications complete all as specified and as directed. Note :- Rate quoted for Sr Item No. 59.00 is inclusive of provision cost of Sr Item No. 59.03 & 59.04
79Taking down of existing armstrong type false ceiling carefully, and re-fixing the same after installation of new ducts including removal of existing old air ducts.
80M&L for Earthing complete with GI earth plate electrode 600x600x6 mm thick buried directly in ground earth pit not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below ground level connected to GI earth lead strip 20 x 4 mm size by mean of nut/bolt and washer ofGI as shown in electrical plate no 3 of SSR part I including necessary excavation and earth work GI pipe 20mm dia light grade for watering etc, PCC pit chamber with PCC cover in cement concrete 1:3:6 Type C2 with 40 mm thick Precast RCC cover slab 1:2:4 type B 0 with 8 mm dia TMT bar and handle withlifting hooks, adequate quantityof charcoal dust and common salt mixed with ordinary paddy field earth 20% etc including testing complete all as specified and as directed.
81Supply, Install, Testing and commissioning, pedestal mounted factory made cubical totally enclosed made out of 2 mm thick CRCA Sheet steel with hinged double door type and locking arrangements, powder coated suitablefor operation on 3 phase, 50 Hz, 415 Volts, with and including provision of the following items :- a) Copper Busbar for 3 phases and neutral of capacity 250 Amps. b) MCCB 4 Pole, 200 Amps, 36 KA, Microprocessor type with in built ground fault protection as main incomer - 01 No c) MCCB 4 Pole 63 Amps, 36 KA, Thermal magnetic type -03 Nos.( For package AC Units) d) MCB 4 Pole 10 KA, 32 Amps-06 Nos. (For water Pumps, cooling Tower motor and Capacitor Controls) e) Ammeter AC with suitable CTs and selector switches -01 No. f) Voltmeter with selector switch -01 No.
82g) LED Indicator lamps 3 Sets for R, Y,B Phases. h) 7.5 KVAR fixed capacitor for Power Factor Improvement -03 Nos . j) Energy Meter 3 phases 4 wire with suitable CTs -1 No. k) Control/main wiring for all equipments with suitable size PVC insulated single care Copper conductor-01 lot.
83Supply and fixingof molded case circuit breaker CG Cat Part No:- NSX250F, COMPACT NSX TYPE 3 PHASE 250 AMP, 690 VoltAIC rating – 36 KA @ 415 V complete all as specified and as directed.
84Supply & fixing of Single Phase Preventer VSP-2 / VSP-3/ VSP D-2 type,415 V,TP complete all as specified and as directed.
85Renewal ofball bearing( size No 6203) for electric induction motor of 2 HP to 5HP capacity complete all as specified and as directed.
86Renewal ofball bearing for AHUof 3 x 15 TRcapacity complete all as specified and as directed.
87Renewal of thermostate / temperature control switch suitable for 1x15 TRAir Cooled package type AC plants complete all as specified and as directed.
88Renewal of anti freeze switch suitable for Central/ package type AC plants complete all as specified and as directed.
89Renewal of drier for liquid line suitable for 3x 15 TR capacity compressor complete all as specified and as directed.
90S&F in repairs including testingharmeticallysealed scroll Compressorof capacity 5.5 TR suitable for existing 3 x 15 TRAir Cooled package type AC indoor unit of 3 x 15 TR capacities (Model No. ZR72KCG-TFD-52 E ofEMERSON), suitable for407(c) non CFC refrigerent gas including necessary brazing work to make the system leak proof complete all as specified and as directed.
91M&L for Taking down/ dismantling of portion of false ceiling for internal cleaning of air ducts with cloths with care and deposting the dust particles in container,removing the grills/ diffusers,and refixing the grills, diffusers and false ceiling in its original locations including renewal of screws complete all as specified and as directed (3 x 15 TR).
92Renewal of drier for liquid line suitable for 3 x 15 TR capacity compressor complete all as specified and as directed.
93Renewal of thermostate / temperature control switch suitable for 3 x 15 TRPackage type AC plants complete all as specified and as directed.
94Supply and charging of Refrigerent gas R-407 (c) Non CFC (ecofriendly)in company sealed cylinders of any capacity complete all as specified and as directed. Note: If the recharged refrigerent gas is leaked within one month of running of AC plant, the contractor shall recharge gas (including supply) without any extra cost to department.
95Renewal of V Belts of size B-40 to B-60 complete all as specified and as directed.
96S&F in repairs thermostatic expansion valve of 3 x 15TRworking on R-407 (c) NON CFC refrigerent gas (Ecofriendly) Air cooled package typeAC plant (Make - Blue Star)including collecting the refrigerent in the empty cylinders arranged by Contractor at his own resources by any means, cutting, welding, brazing, renewal of gasket, nuts, bolts and washers etc complete all as specified and as directed.
97Dismantling/ taking down burnt squirrel Cage Induction Motor of any capacity, 3 Phase, 415V, 1450 RPM of anymake from its base and transporting the motor to the Contractor"s workshop and back, refixing the motor at site after carrying out the following repairs/ renewals complete all as specified and as directed :- (i) opening the side covers and removing the rotor and cutting/ removing the burnt coils / winding from stator. (ii)Cleaning the slots carefully (iii) Rewinding the stator using super enamelled copper winding wire with same size, number of coils, number of turms/ coils as per data acquired from the old burnt motor,including varnishing two coats, drying and reassembling the electric motor at site (iv) Testing the coils for there continuity and no current passing through the stator core.
98(v) Dynamic testing of the rotor and alignment of the main shaft and ensure that no imbalance vibtrations. (vi) Re-assembling the rotor and connecting the end terminals to the terminal plate of the motor, closing the ends with side covers (vii)Testing and commissioing theelectric motor connecting to the electric supply to its full load by connecting the compressor. (viii) Renewal of Bolts, nuts and washers Note :- Parts renewed i.e Ball bearing shall be measured and paid separately. However filling of grease and oiling extra shall be deemed to be included in Unit rates.