Tcmc Zone - 1 Gf 2023-24 -Reparis To Adam Nagar Public Toilet ( Ward No. 12 )

Key Value

Document Fees
Refer document
EMD
INR 3850.0 /-
Tender Value
INR 3.85 Lakhs /-

BOQ Items

Name of Work:Reparis toAdam Nagar Public Toilet@ (Ward No. 12)
Sl. No. Item Description
1Supplying and fixing in position Indian water closet of size 580 X 440mm, white glazed earthen ware of approved quality with "P" trap or "S" trap confirming to IS:2556 -Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers.
2Supply and position colour Glazed European water closet best quality and approval make with 100 mm P or S trap with Double flapped rigit PVC sheet cover with C.P brass inches with 10 litres PVC low level flushing tank with all inertial fitting etc completes as per standard specification
3Water tight bulk head fitting suitable for 100/60 watts lamp with guard heavy type (PHILIPS/ BAJAJ/ CROMPTON GREAVES)
4Supply and fixing of 5 pin 15Amps plug point etc complete as per PWD specification
5Wiring with 2 x 2.5 sp.mm PVCunsheathed SC, Alu. Cable of 650 V Grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with suitable coilor with continoius earth wireconnection of 14 SWG TC wirefor open PVC light point (SD20)
6Supply and fixing of 4 feet Flouresent Tube light etc complete as per standard specification
7Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.,
8Supply and fixing of following PVC materials etc complete as per standard specification
94” PVC pipe
104” PVC Tee
114” PVC Bend
12Earthing as per PWD standard specification with necessary masonry works etc., complete as per standard specification
13Laying and jointing of PVC pipe etc complete as per standard specification
14Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVCheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter.
15White washing two coats using best shell lime including cleaning , curing cost and conveyance incidentalcharges etc., complete as per standard specification.
16Distempering two coats of best oil bound distemper of approved colour and quality including preparation of surface including cost and conveyance of all materials and all other labour charges etc.
17Supply anddelivery of 2-HP single phasesubmersible pump set Duty 20lpmX150M head, inlcuding cost and conveyance of material etc., complete as per standard specification
18Supply anddelivery ofsingle phasepanel Board with two level guard with Auto start for 2 hp single phase submersible pumpset inlcuding cost and conveyance of material etc., complete as per standard specification
19Supply and delivery of 32mm G.I pipe (medium) asper IS 139/PARTI/90 inlcuding cost and conveyance of material etc., complete as per standard specification
20Supply and delivery of 32mm Jackey Coupling (long) inlcuding cost and conveyance of material etc., complete as per standard specification
21Supply and Delivery of PVC Insulated and Sheathed 3 core 4sqmm flate type copper cable Confirming to IS 694/1990 inlcuding cost and conveyance of material etc., complete as per standard specification
22Supply and delivery of32mm G.M gate valve inlcuding cost and conveyance of material etc., complete as per standard specification
23Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gagues upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and train run for 10 days
24Supplying and laying TAMIN Paver Block of size 60mm thick,M40 grade Providing and laying of80mmthick high strength type conforming IS 15658-2006 of rubberized interlocking paver lock in size of minimum compressive strength of 40N/mm2 in uniform shape of approved make to be laid in flurring bone pattern with Stone dust cushionbelow the uniform shap of approvednon skitting surface in the top and the rate including levelling the base preparation ofpavers as sub base, Stone dustcushion150mm thick layingout of pavement cut the pieces to fix the edge vibring the pavers,sweeping tranporting loading unloading of laying paver block as per standard specification,.