| 1 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 2 | 20 mm |
| 3 | 25 mm |
| 4 | Dismantling and re-fixing of following Dia sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 5 | 20 mm Dia |
| 6 | 25 mm Dia |
| 7 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. |
| 8 | 3 x 1.5 sq. mm |
| 9 | 4 x 1.5 sq. mm |
| 10 | 5 x 1.5 sq. mm |
| 11 | 6 x 1.5 sq. mm |
| 12 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 13 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 14 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 15 | 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire |
| 16 | Supplying and fixing 6 way double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 17 | Supplying and fixing 63 A TP&N MCB inside the existing panel board including deilling holes in panel, Mking connections etc as required |
| 18 | Supplying and fixing of following rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 19 | Single pole |
| 20 | Single Pole & neutral |
| 21 | Supplying and fixing 5/6 amps switch piano type/tumbler switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 22 | Supplying and fixing metal box of size 200 mm X 150 mm X 60 mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 23 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 Amodular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 24 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 Amodular switch, connections etc. as required |
| 25 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 26 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. Mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 27 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories includingsafety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 28 | Supplying, Installations, Testing and commissioning of 70 watt LED high efficiency wellglass advanced design luminaires suitable for industrial use, housing made of pressure die cast aluminium powder coated with ingress protection of IP66, consumes lesser energy and maintain high lighting levels. Connection with 3x1.5sqmm FRLS copper wire, 1no. eyebolt provided for mounting purpose on godown truss/wall along with all accessories such as clamp, nuts, bolts, complete in all respect etc as required |
| 29 | Supply of Surface waterproof industrial luminaire with polycarbonate housing and diffuser suitable for twin 4ft T8 tube along with 2 Nos of 20/22 Watt LED polycarbonate T8 tube with in build driver with metal heat sink and Installation, testing and commissioning of pre-wired,LED fitting,complete with all accessories and tube/lamp etc. directly on nceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required |
| 30 | S/I/T/C of highly robust industrial luminaire suitable for single LED tube & 20w LED tubeincluding all accessories i.e., installation on wall/truss/pipe, wiring with 1.5sqmm wire, painting, screw etc as required. |
| 31 | S/I/T/C of 30W street light of pressure die cast housing alongwith Prismatic polycarbonate optic with IP66 protection, including all accessories i.e., installation on wall/truss/pipe, wiring with 1.5sqmm wire, painting, screw etc as required. |
| 32 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required |
| 33 | Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required |
| 34 | P/F of cable termination of M.S. box of size 15cm X 15cm X 10 cm with compression termination arrangements, 6-10 Amp SP MCB and double natural link etc as required. |
| 35 | Supply and Laying of one number additional PVC insulated and PVC sheathed / XLPE XLPE POWER CABLE of 1.1 kv grade armoured Al. cablecompulsory ISI mark confirming to IS:7098/ PART –I / 88 with amendment no.1 (clamped with 1mm thick saddle) on the wall surface as reqd. |
| 36 | CABLE SIZE 2 X 10 SQ.MM |
| 37 | Supply, Installation, Shifting, testing & commissioning of Double door, outdoor cubicle type totally enclosed free standing type moisture, dust and vermin proofPanel Board of minimum size 0.8mx1mx0.4m made out of 2.0 mm thick CRCA sheet Steel IP 42 Wall / floor mounting type. The sheet steel shall undergo minimum 9 tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes415 V 250 Amp electrolitic Aluminium Bus Bar, removable gland plates, cable glands,including connection with outgoing feeders completeinall respect. All MCCB shall have thermalmagnetic release with adjustable over current,short circuit & Earth fault protection with trip history (Faulty phase, type of fault and interupted Current) as per specification & BOQ. All MCCB\"s shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L &S/Ctrip setting as per load requirement. All TP MCCB shall be with solid isolable neutral link.The breaking capacity specified is Ics value. All outgoing MCB\"s shall be C type with 10 KA breaking capacity. The fault withstanding capacity of panel shall be 25 KA rms for 1 sec. The above board shall be complete with 3 nos. phase indicating lights, flush AVF meter with, CT\"s, PT\"s, selector switches, protective fuses etc. at Incomer with all inter connections by min. 2.5 sq.mm. Copper wires. 1 no. 100 Amp FP Moulded Case Circuit Breaker. (25 KA)1no. 100 Amp changeover switch 2nos. 63 Amp FP Moulded Case Circuit Breaker. (16 KA)2nos. 63 Amp FP Miniature Circuit Breaker. (10 KA)5nos. 32 Amp DP Miniature Circuit Breaker. (10 KA) |
| 38 | Less creditfor old damaged Flourescent fitting/batten etc. as required |