Tender For Repair/Maintenance Of Fans, Summer Appliances And Water Coolers Etc At Afs Bihta, bihta-Bihar

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Fans, Summer Appliances And Water Coolers Etc At Afs Bihta. Submission Date for this Tender is 21-06-2023. Air Conditioner Tenders in bihta Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

37871284
Corrigendum : Tender For Repair/Maintenance Of Fans, Summer Appliances And Water Coolers Etc At Afs Bihta
Open Tender
Indian
Bihar
bihta
21-06-2023

Tender Details

Repair / Maintenance Of Fans, Summer Appliances And Water Coolers Etc At Afs Bihta

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Jun-2023 Revision of BOQ BOQ 14-06-2023
2 14-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 38000.0 /-
Tender Value
INR 19 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINTENANCE OF FANS, SUMMER APPLIANCES AND WATER COOLER ETC AT AF STN BIHTA
Sl. No. Item Description
1Material and labour for disconnecting electric connection, taking down/ keeping aside the air conditioner (Split/Window) and Water Cooler including stabilizer of any make and capacity, Servicing the same as cleaning inside by means of cleaning of filter, removing dust from body, tightening of loose nut, bolt, washer, rubber gasket and tightening of loose wiring, loose connection, replacement of wornout nut, bolt, washers, gasket etc and necessary cutting, welding/soldering works with replacement of rusted body parts with new MS/GI Sheets of suitable size and making the equipment fully functional and Re-installation in position and testing, complete all as specified and directed by Engineer-in-charge. Note: (All new spare parts will be measured and paid separately under the appropriateitems as supply only).
2Material and labour for detection and rectification of leakages in gas line by necessary brazing in 1.5 Ton/2.0 Ton window/split type AC of any model and any make and ensuring the complete systems leak proof including checking the system and replacement of required spare parts including charging of refrigerant gas R-134/R-134A/22/32/410A with appropriate quantity including testing for smooth functioning all as specified and directed. Note: Spare parts, if requited will be measured and paid separately under the supply of appropriateitems.
3Material and labour for dismantling of unserviceable/worn hermetically sealed unit compressor from window/Split type AC and replacement with new compressor suitable for existing same model/make of capacity 1.5 TR split/window type AC including brazing with suction and discharge line, checking the system for leak proof and inclduingcharging of refrigerant gas R-134/R-134A/22/32/410A in appropriate qty after making vaccume the complete system and testing the AC for proper functioning all as directed.
4Allas per item No-12 here in before but of capacity 2.0 TR split type AC, complete all as specified and directed.
5Supply and fixing the following spares parts required for repairs for window/split type AC or water coolers of any capacity against item No 1.00 here in above complete all as specified and directed by Engineer-in-Charge: - Note: All the repairs shall be carried out at AGE E/M store yard including transportation of equipment and re-fixing at site: - Supply only Cooling coil complete with fins made of copper suitable upto 2Ton/1.5 Ton capacity Window/Splittype AC.as per existing size and specification
6Supply only Condensing coil complete with fins made of copper suitable for upto 2Ton/1.5 Ton capacity Window/Splittype AC as per existing size and specification, complete all as specified and directed.
7Supply only condenser of suitablecapacity for AC 1.5/2.0 Ton, complete all as specified and directed.
8Supply only Fan motor of suitable capacity for 1.50/2.0 TR split/window AC, complete all as specified and directed.
9Supply only Fan blade suitable for AC"s blower/ water cooler motor and all as per sample, complete all as specified and directed.
10Supply only indoor blower motor for AC"s of 1.5/2.0 Ton capacity and all as per sample, complete all as specified and directed.
11Supply only outdoor motor incl bladesfor AC"s of 1.5/2.0 Ton capacity and all as per sample, complete all as specified and directed.
12Supply only indoor blower for AC"s of 1.5/2.0 Ton capacity and all as per sample, complete all as specified and directed.
13Supply only Condensing coil suitable for water cooler upto 120 Ltr capacity copper made, complete all as specified and directed.
14Supply only Cooling coil suitable for water cooler upto 120 Ltr capacity copper made.
15Supply only Water outlet tap made of brass chromium plated for water cooler upto 120 Ltr capacity, complete all as specified and directed.
16Supply and fixing of unserviceable wall mounted stand for outdoor unit of splite type AC of 2Ton/1.5 Ton capacity, complete all as specified and directed.
17Supply only Liquid line valves copper made for ACs upto 2Ton capacity, complete all as specified and directed.
18Supply onlyRefrigerant line valve copper made suitable for ACs upto 2Ton capacity, complete all as specified and directed.
19Supply only Foam insulation heavy duty for section/discharge pipe for ACs refrigerant line, complete all as specified and directed.
20Supply only temperature sensor for AC cooling as per existing, complete all as specified and directed.
21Supply only Capillary tube for water cooler/refrigerator/AC all as per exiting size, complete all as specified and directed.
22Supply only Vegitable tray for refrigerator all as per sample upto 320 Ltr capacity, complete all as specified and directed.
23S&F Running capacitor 80/100 mfd +/- 400 V AC, Suitable for1.5/2.0 TR window/split type AC including taking down unserviceable old one, complete all as specified and directed.
24S&FStarting capacitor 80/100mfd +/-5% 400 V AC Suitable for1.5/2.0 TRwindow / split type AC including taking down unserviceable old one, complete all as specified and directed.
25S & F Over load Relay of water cooler/deep freeze/Refrigerator including taking down unserviceable old one, complete all as specified and directed.
26S & F Thermostat switch (DT 50-1052), suitable for 1.5 Ton/2 Ton split / window type AC, including taking down unserviceable old one, complete all as specified and directed.
27S & F Blower/Propeller fan motor Single Phase 230 V AC, 50 Hzas per existing sample for indoor unit including taking down unserviceable old one, complete all as specified and directed.
28S & F Blower/Propeller fan motor single phase 230 V AC, 50 Hzas per existing sample for outdoor unit including taking down unserviceable old one, complete all as specified and directed.
29S & F Stainer/Filter (copper) Suitable for window type AC of 1.5/2.0 TR cooling capacityincluding taking out the old one, complete all as specified and directed.
30Supply and FixingElectronicCircuit plate (PCB)for Split/Window A/C1.5 TR/2 TR including taking down unserviceable old one, complete all as specified and directed.
31M&L for repairing the Electronic circuit plate(PCB) for various types and capacity of air conditioning unit including cleaning the parts of the indoor units all as specified and directed by Engineer -in-Charge.
32S&F stabilizer of capacity 5 KVA suitable for split/window type AC of 2Ton/1.5 Ton capacity, complete all as specified and directed.
33Taking out the unserviceable sealed compressor unit from water cooler and S&F New Sealed compressor unit as per existing sample, suitablefor 40/80 Ltr capacity of water cooler (duly tested) and checking the complete system for leak proof and including charging of refrigerant gas R-134 a in appropriate quantity and testing for smooth functioning complete all as specified and directed.
34M&L detection and rectification of leakage in gas line by necessary brazing/soldering in water cooler of any capacity, any type and any make and ensuring the system leak proof and replacement of required spare parts Including charging of refrigerant R-134 A in appropriate quantity in the system and testing for smooth functioning of water cooler, complete all as specified and directed.
35Supply and fixing running capacitor 25/30 mfd ± 5%, 400 voltfor Water Cooler having capacity 40/80 and 150Ltr iincluding taking down unserviceable old one, complete all as specified and directed.
36Supply and fixingover load Relay for Water Cooler having capacity 40/80 and 150Ltr including taking down old one, complete all as specified and directed.
37Supply and fixing Float valve of 15mm dia non-metallic for Water Cooler having capacity 40/80 and 150Ltr including taking down old one, complete all as specified and directed.
38Supply and fixing PVC connectionof size 15mm dia for Water Cooler having capacity 40/80 and 150Ltr including taking down unserviceable old one, complete all as specified and directed.
39Supply and fixing PVC waste pipe of size25 mm dia for Water Cooler having capacity 40/80 and 150Ltr including taking down unserviceable old one, complete all as specified and directed.
40Supply and fixing copper section pipe of suitable size for water cooler incl taking down old one, complete all as specified and directed.
41Supply and fixing copper discharge pipe of suitable size for water cooler incl taking down old one, complete all as specified and directed.
42Supply and fixing single pole magnetic contactor for outdoor/indoor AC 220 Volts (Black) of suitable capacity including taking down old one, complete all as specified and directed.
43Supply and fixing double pole magnetic contactor for outdoor/indoor AC 220 Volts (Black) of suitable capacity including taking down old one, complete all as specified and directed.
44Supply and fixing drain pipe of suitable size for ACs of 1.5/2.0 Ton including taking down old one, complete all as specified and directed.
45Supply and fixing swing motor of suitable capacity for AC"s indoor unit of 1.5/2.0 Ton including taking down old one, complete all as specified and directed.
46Supply and fixing indoor unit filter of suitable size for ACs of 1.5/2.0 Ton including taking down old one, complete all as specified and directed.
47M&L for detection and rectification of leakages in gas line by necessary brazing in refrigerator of 300/310Ltr capacity of any model and any make and ensuring the complete systems leak proof including charging of refrigerant gas R-134 Awith appropriate quantity including testing for smooth functioning and checking the system and replacement of required spare parts and complete all as specified and directed. Note:Spare parts like filter, capillary tube, cooling coiled, condensing coil if required will be measured and paid separately
48M& L for replacement of relay, suitable for 300/310 Ltr refrigerator of any make/model including taking down unserviceable old one, complete all as specified and directed.
49S & F PVC insulated 2.5 sqmm, 3 core, copper conductor wire with approved colour coding (Phase-red, Neutral-black, Earth-green) complete ISI marked drawn in and including flexible conduit including taking down old one, complete all as specified and directed.
50S & F sub main wiring using approved colour coding (Phase-red, Neutral-black, Earth-green) complete with two single core FRLS PVC insulated and unshealthed stranded copper conductor cable 4 sqmmas current carrying conductor drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated, unshealthed, stranded copper conductor of size 4 sqmm as earth conductor including taking down old one, complete all as specified and directed. Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.
51S&F Sheet metalenclosure with socket plug top and MCBs single pole with a two pin and earth plug andsocket complete with one single pole MCB of"C" series of cap 16-32 Amps including taking out the old one, complete all as specified and directed.
52Supply and fix switch socket combination, 2 in 1, of capacity of 5/6 Amps and 15/16 Amps, 6 pin incl taking out old one, complete all as directed by Engineer-in-Charge.
53Supply and fix plug top of capacity 05/06 Amps with suitable make incl taking out old one, complete all as specified and directed.
54Supply and fix plug top of capacity 15/16 Amps with suitable make incl taking out old one, complete all as specified and directed.
55S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used single pole and neutral 8 ways 220 volt with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plate, including fixing DB flush in wall complete with making good disturbed surfaces and colour matching all as specified and directed including taking down old one, complete all as specified and directed.
56S&F MCB’s single pole, 10 KA ,10 Amp to 32 Amp 240 Volts, ""B"" series with required wiring connections and lugs etc and erecting in provided enclouser/distribution board, MCBs shall be of current limiting type, ISI marked conforming to IS 8828-1996, including taking down old one, complete all as specified and directed.
57S&F MCB’s single pole and neutral, 10 KA, 32 Amp to 40 Amp 240 Volts, ""B"" series with required wiring connections and lugs etc and erecting in provided enclouser/distribution board, MCBs shall be of current limiting type, ISI marked conforming to IS 8828-1996, including taking down old one, complete all as specified and directed.
58Material and labour for taking down of ceiling fan/exhaust fan/wall mounted fan/pedestal fan from ceiling/wall and replacement of wornout steel split pin, rubber reel, washer, screws, nut bolts etc, greasing/ oiling of the fan including rectifying the defective wiring, cleaning complete and making the same functional, refixing in position and testing complete all as specified and directed by Engineer-in-charge. Note: Item required for repairs shall be measured and paid separately under appropriate items.
59Supply and fixing the following items /spare parts for serial item No 58.00above complete all as specified and directed by Engineer-in-charge. (a) Supply only fan clamp made of SS.
60(b)Supply only Fan capacitor 2.5MFD
61(c) Supply onlyFan capacitor 3.15MFD
62(d) Supply onlyMS down rodmade of GI 15 mm dia, 1Ft long.
63(e)Supply only Aluminium fan blade set 1200/1400mm sweep
64(f)Supply onlyMS mounting clamps for Exhaust fan with frame suitable upto for 300mm/450 mm sweep exhaust fans.
65(g)Supply only metal Exhaust fan blade suitable for upto 300mm/450 mm sweep exhaust fans.
66(h)S&F Electronic fan regulator stepped type (flush type) 240 volt, 50Hz, single phase on existing phenolic laminated sheet including taking down old one and connecting, complete all as specified and directed.
67Material and labour for dismantling/ opening complete fan obtained from item No 58 here in before, assembling and testing complete after the following repairs : (a) Supply and fixing fan bearings Make : SKF/NBC/TATA and all as per existing.
68(b) Supply and fixing gun metal bushes all as per sample.
69Material and labour for dismantling, opening complete Fan obtain from item No 58.00 and rewinding the same with super enamel copper conductor of suitable size and meet to original specifications & speed etc. Using proper insulation and varnish, sleeves etc asssembling and 8hrs continous testing before refixing at site, complete all as specified for the following sizes : Note : (i) Rewinding/ repairs of fans shall be carried out at AGE E/M store yard including transporation charges to and from site. (a)Ceiling Fan 1200/1400mm sweep.
70(b)Exhaust Fan 450mm/300 mm sweep
71(c) Wall mounted/ Padestel Fan 450mm sweep
72Supply and fixing LED tube lights fitting 1x18W, 220V, including LED tube light, minimum 100 lumens per watt, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and complete all as specified and directed by Engineer-in-Charge.
73Supply and fixing LED tube lights fitting 1x 10W, 220V, including LED tube light, minimum 100 lumens per watt, connecting up with three core flexible copper conductor cable of suitable size from ceiling roseand complete all as specified and directed by engineer-in-charge.
74Supply and fixing exhaust fan, steel body AC single Phase, 230V of size 300mm sweep with blades and frame and louvers and complete incl taking out old one, complete all as specified and directed by Engineer-in-charge.
75Supply and fixing exhaust fan, steel body AC single Phase, 230V of size 450mm sweep with blades and frame and louvers and complete incl taking out old one, complete all as specified and directed by Engineer-in-charge.
76Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00, BEE Five star rated with brushless direct current motor (BLDC) and complete incl taking out old one, complete all as specified and directed by Engineer-in-Charge.
77Material and labour for taking down of electric water heater from wall of capacity 25/50 ltrs, dismantling/opening the same, servicing, cleaning and replacement of wornout MS nut, bolts, washers, clamps etc and making the same fully functional including assembling, connecting and testing, complete all as specified and directed by Engineer-in-charge.
78M&L for non return valves cast copper alloy ISI mark 15 mm diaincluding taking out the old one, complete all as required and as specified.
79M&L pressure release valve of brass inner threaded of 15 mm dia or as per sample approved by EIC including taking out the old one, complete all as specified and directed.
80M&L pressure release valve of brass outer threaded of 15 mm dia or as per sample approved by EIC including taking out the old one, complete all as specified and directed.
81M & L PVC insulated copper conductor cable, 3 core, 40/0.0076,AC 1100 volts grade including taking down U/S cable, complete all as specified and directed.
82M&L Metallic fastener bolt 75mm long 8mm dia with nut and washer for hanging Geyser, complete all as specified and directed.
83M&L painting of complete outer body of storage type geyser of capacity 25 to 50 litres with one coat of red oxide primer and over it two coats of synthetic enamel paint including preparing surface and including writing of MES No with black ynthetic enamel paint, complete all as specified and directed.
84M&L painting and repairing of complete outer body of desert cooler with one coat of red oxide primer and over it two coats of synthetic enamel paint including preparing surface and including writing of MES No with black synthetic enamel paint, complete all as specified and directed.
85S&F 15 mm dia GI tubing, medium grade, with all GI fittings and fixed complete to walls, ceilings and floors, complete all as specified and directed.
86M&L for multifunction safety valve cast copper alloy 15 mm dia ISI marked including taking out the old one, complete all as specified and directed.
87S&F in repairs Bib taps cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for union, 15mm dia, complete all as specified and directed.
88S&F switch piano flush button single pole one way 15 Amp, 240 Volts conforming to IS 3854 ISI marked including taking down old one, complete all as specified and directed.
89S&Ffor socket outlet, 3 Pin, 15 Amp flush type conforming to IS 1293 ISI marked including taking down old one, complete all as specified and directed.
90Supply and replacement of Rubber Gasket flange as per site requirement for 25/50 ltr geyserincluding taking out the old one, complete all as specified and directed.
91S&F stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete of 15 mm dia including taking out old UNSV, complete all as specified and as directed.
92S & F modular switch socket combination, 2 in 1, 6 & 16 A, 6 pin, 240 volts AC, including taking down old one, complete all specified and directed.
93Supply and fixing desert cooler made out of GI sheet of thickness not less than 20 gauge and top and bottom cover not less than 18 gauge, 240 volts AC, electric driven (single phase), capacity having nominal air flow capacity of 4000 Cum per Hour, complete all as specified and as directed with the following specifications: - a) Fan sweep 450mm with aluminium blades duly factory painted. b) Propeller cooler fan motor max 150 watt, ISI marked. c) Submersible pump with 1.50 m head and 8-10 LPM water discharge. d) Three speed control including on/off switch. e) Pump on/off switch. f) Capacity of water storage tank Min 100 Ltrs. g) Minimum overall size 60cmx60cmx120cm. h) Min 25 mm thick cellulose evaporative Honey combed cooling pads on three sides i.e. rear, left and right.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail