| 1 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 11 KV line on 9 mtr. ST poles, 30mm² ACSR Conductor at WSS Seen Thakran. |
| 2 | 9 mtr. Long ST Pole (ST-410 SP-33) |
| 3 | GI V Cross -arm with top Bracket including clamps |
| 4 | GI Channel X-arm including clamps and Angle for braces |
| 5 | 30mm² ACSR conductor |
| 6 | PG Clamps for 30mm² ACSR conductor |
| 7 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
| 8 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting |
| 9 | Galvanized Nuts and Bolts |
| 10 | Danger Plates with Clamps |
| 11 | Anti climbing device with clamps |
| 12 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm |
| 13 | Painting of 9 mtr ST poles with One coat of Red oxide Paint. |
| 14 | Painting of 9 mtr ST poles with two coat of Aluminium Paint. |
| 15 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
| 16 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 17 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for installation of 100 KVA Sub Station at WSS Seen Thakran Stage-Zero. |
| 18 | 11/0.433 KV, 3-phase distribution Transformer 100 KVA with Bimetallic Terminal Connectors Energy Level-2 AluminiumWound, & with LV Cable box having detachable Aluminium Gland plate |
| 19 | Gapless surge Arestor, 9 kv, 10 KA , LA with polymer housing stn. Type |
| 20 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
| 21 | 11 KV Horn gap fuse set 3 phase 200 A |
| 22 | 185mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type |
| 23 | 9 mtr. Long ST pole (ST-410 SP33) |
| 24 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75Positive and 80 KV Negative, creepage distance 320mm with fitting |
| 25 | GI Channel /Angle/flat of sizes including clamps |
| 26 | Galvinized Nuts and Bolts. |
| 27 | Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mmfor connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover |
| 28 | 11 KV Poloymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm |
| 29 | LT distribution box for 100 KVA DTR with MCCB for incomer and SFU\"s for outgoing circuits |
| 30 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
| 31 | PG Clamps |
| 32 | Danger Plates with Clamps |
| 33 | GI Barbed wire for Anticlimbing |
| 34 | 3-phase 4-wire Prodigy meter with box |
| 35 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
| 36 | Painting of ST poles 9 mtr. long with 1 coat of Red oxide & 2 coat of Al. paint |