Power Government Departments Closing in 0 days TDR #37860577

Tender For Supply Of Pressure Transmitter (Pt) And Differential Pressure Transmitter (Dpt) At Katpp, Jhalawar

Issued by Government Departments · jhalawar, Rajasthan
Tender Value
50.21 Lakhs
Estimated cost
Bid Submission
02 Aug 2023
0 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jhalawar → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply Of Pressure Transmitter ( Pt ) And Differential Pressure Transmitter ( Dpt ) At Katpp, Jhalawar , Dpt Sh Ist & Ii Nd Stage Flow Tx, Rh Dsh Flow, Blr Cont.Blowdown Flow Unit: Kpa Measuring Range-: -500 To 500 User Range / Calibration Range:0 To 250 , Dpt Drum Level Tx. Unit: Mmh2o Measuring Range-: -800 To 800 User Range / Calibration Range: -600 To500 Mmh2o , Dpt Pa Flow, Aph Pa Inlet & Outlet Dp, Secondary Air Flow, Aph Sa Inlet & Outlet Dp Unit: Kpa Measuring Range-: -2.0 To 2.0 User Range / Calibration Range:0.1 To1.5 , Dpt Feed Control Stn In &Out Dp Unit: Mpa Measuring Range-:- -0.12 To10.0 User Range / Calibration Range:0 To 10.0 , Dpt Sh Spray Water Flow Unit: Kpa, Measuring Range-: -500 To 500 User Range / Calibration Range:0 To 500 , Dpt Rh Spray Water Flow, Main Feedwater Flow Unit: Kpa Measuring Range-:-160 To 160 User Range / Calibration Range:0 To 60 , Dpt Cont.Blowdown Tanklevel Tx Unit: Mmh2o Measuring Range-:-0.0 To 1500 Mmh2o User Range / Calibration Range:0.0 To1500 , Dpt Ldo Tank Level Tx ( Capillary Type ) Unit: Mmh2o Measuring Range-:0 To 8500, User Range / Calibration Range: 0 To 8500 , Dpt Hfo Tank Level Tx ( Capillary Type ) Unit: Mmh2o Measuring Range-: 0 To 13000 User Range / Calibration Range: 0 To 13000 , Pt Furnace Press Tx., Aph Inlet And Outlet Gas Press, Esp Intel Gas Press, Id Fan Inlet Press, Gas Press Fur. Cavity Unit: Kpa, Measuring Range-:-8.0 To 8.0, User Range / Calibration Range: -8.0To1.0 , Pt Main Feedwater Press, Drum Press Tx., Sh Out Press, Main Steam Press, Sh Spray Water Press., Main Feedwater Mov Front Press., Cont. Blowdown Tank Press. Tx Unit: Mpa Measuring Range: -0.1 To 40.0 User Range / Calibration Range: 0 To 30.0 , Pt Secondary Air Pressure Tx., Aph Inlet Sec Air Press, Fd Fan Out Press, Furnace Sec. Air Box Press, Furnace Pressure Unit: Kpa, Measuring Range-: -60 To 60 User Range / Calibration Range: -7.0 To 7.0 , Pt Aph Out Hot Pa Press, Aph Inlet Pa Press , Mill Separator Outlet Pressure , Mill Sealing Air Pressure, Mill Pa Pressure Scanner Air Outlet Pressure Unit: Kpa Measuring Range-:-100 To 400, User Range / Calibration Range:0 To 30.0 , Pt Id Fan Outlet Press Unit: Kpa, Measuring Range-:-2.0 To 2.0 User Range / Calibration Range:0 To 2.0 , Pt Cw / Acw Header Pressure , Instrument Air Pressure, Cw Outlet Pressure Iac / Cac Air Pressure Unit: Mpa, Measuring Range-:0 To 1.5 User Range / Calibration Range:0 To1.5 , Pt Rh Spray Water Press, Ibd Flash Tank Inlet Press. Tx, Turb , Rh Spray Wtr Press Rh Inlet / Outlet Press Unit: Mpa Measuring Range-:-0.1 To 16.0 User Range / Calibration Range:0 To 15.0 , Pt Turbine Stm Prs After Gov Stage1 Unit: Mpa Measuring Range-:0 To 15 User Range / Calibration Range:0 To 15 , Pt No1 Hph I / L Stm Prs Unit: Mpa, Measuring Range-:0 To 10 User Range / Calibration Range:0 To 10 , Pt Hpbp Behind Stm Prs 1, Hp Turb Exhaust Stm Left Prs , Hp Turb Exhaust Stm Right Prs, Hp Turb Exhaust Stm Hdr Pipe Prs , Reater I / L Stm Prs, Crh To Bept Stm Prs, Rh O / L Stm Press , Rh O / L Stm Press , Rh O / L Stm Press , No2 Hph I / L Stm Prs, Crh To Bfpt Stm Prs, Cold Rh Stm To Aux Stm Prs, No 2 Hph I / L Stm Unit: Mpa, Measuring Range-:0 To 6 User Range / Calibration Range: 0 To 6 , Pt Dearator Press 1, 4 Sect. Extr. To Aux Stm Prs, 4 Sect. Extr. To Dea Mov Frt Prs, 4# Extr. To Mfpt Press, Aux Stm To Bfpt Stm Prs., Mfpt A I / L Stm Prs., Aux Stm To Bfpt Stm Prs, Gen Stat Cw I / L Wtr Flow, No5 Lph I / L Stm Prs, Turb Hp&Ip Gas Gland Stm Prs. 1, Gen Entering Hydrogen Pr. No5 Lph I / L Stm Prs Unit: Mpa, Measuring Range-: 0 To 2 User Range / Calibration Range:0 To 2 , Pt Lpbp Vlv ( Hp ) Behind Stm Prs 1 Lpbp Vlv ( Lp ) Behind Stm Prs 1 Unit: Mpa, Measuring Range-:-0.2 To 2 User Range / Calibration Range: -0.1 To 2 , Pt No7 Lph A&B I / L Stm Prs No8 Lph A&B I / L Stm Prs 1 Unit: Mpa Measuring Range-:-0.1 To 0.1 User Range / Calibration Range: -0.1 To 0.1 , Pt Cp Inl Press Unit: Mpa Measuring Range-:-0.1 To 0.5 User Range / Calibration Range: -0.1 To 0.5 , Pt Lub Oil Of Turb Prs Unit: Kpa Measuring Range-: 0 To 5500, User Range / Calibration Range:0 To 5500 , Pt Hp Cond Vacuum Pres 1, Lp Cond Vacuum Press 1, Hp Cond Vacuum Prs 1, Lp Cond Vacuum Prs 1, Bfpt B Exhust Vac Press, Bfpt A Exhust Vac Press Unit: Kpa, Measuring Range-:-100 To 100 User Range / Calibration Range:-100 To100 , Dpt Tdbfbp A I / L Filter Dp, Tdbfbp B I / L Filter Dp Tdbfbd O / L Feed Wtr Flow 2, Tdfpa I / L Filter Dp Tdfp A I / L Filter Dp, Mbfbp I / L Filter Dp, Mbfp I / L Filter Dp, Rh Spray Wtr Flow, Sh Spray Wtr Flow 1, 4# Extr. To Aux Stm Flow, 4# Extr. To Mfpt Unit: Kpa Measuring Range-:-0 To 100 User Range / Calibration Range:0 To 100 , Pt Trub Self-Scanling Gland Htr Prs Unit: Kpa Measuring Range-:-100 To 600 User Range / Calibration Range: -100 To 600 , Dpt Gen Stat Cw Flow, Seal Oil Dp, Hp Bpv In Steam Flow Unit: Kpa Measuring Range-:0 To 250 User Range / Calibration Range:0 To 250 , Dpt Tdbfbp A O / L Feed Wtr Flow 1, Tdbfbp B O / L Feed Wtr Flow 1, Tdbfbp B O / L Feed Wtr Flow 3 Mbfbp O / L Feed Wtr Flow 1 Unit: Kpa Measuring Range-:0 To 40 User Range / Calibration Range:0 To 40 , Pt Ldo , Hfo Supply And Return Press ( With Capillary ) Unit: Mpa Measuring Range-:0 To 5 User Range / Calibration Range:0.1 To 5 , Pt Prds Hdr Press Unit: Mpa Measuring Range-:-0 To 6.3 User Range / Calibration Range:0 To 5 , Pt Mill Loading Oil Pressure Unit: Mpa Measuring Range-:0 To 40 User Range / Calibration Range:0 To 25 , Dpt Mill Sealing Air Dp Sadc / Cadc Press Dp Unit: Kpa Measuring Range-:-60 To 60 User Range / Calibration Range:0 To 5 , Dpt Hfo Filter Dp ( With Capillary ) Unit: Kpa Measuring Range-: -500 To 500 User Range / Calibration Range: -100 To 100 , Dpt Lo Filter Dp ( With Capillary ) Unit: Kpa Measuring Range-:-160 To 160 User Range / Calibration Range:0 To 100 , Dpt Mill Separotor Inlet / Outlet Dp Unit: Kpa Measuring Range-:0 To 40 User Range / Calibration Range:0 To 20 , Dpt Scanner Fan Dp Unit: Kpa Measuring Range-: 0 To 8 User Range / Calibration Range:0 To 6.2 , Pt Scanner Fan Press., Mill Separator Outlet Pressure, Mill Seal Air Pressure, Mill Pa Pressure Unit: Kpa Measuring Range-:-100 To 400 User Range / Calibration Range:0 To 30

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 21-Jun-2023 CORRIGENDUM-I Date 05-Jul-2023
2 05-Jul-2023 NIT EXTENSION ORDER-II Date 19-Jul-2023
3 19-Jul-2023 NIT Extension Order IIIrd Date 02-Aug-2023

BOQ

Name of Work: < SUPPLY OF PRESSURE TRANSMITTER (PT) AND DIFFERENTIAL PRESSURE TRANSMITTER (DPT)AT KATPP, RVUNL, JHALAWAR.>
Sl. No. Item Description
1DPTSH Ist & II nd stageFlow tx,RH DSHFlow,BLRCont.blowdown FlowUnit: Kpameasuring range-: -500 to 500 User Range/calibration Range:0 to 250
2DPTDrum Level Tx.Unit: mmH2Omeasuring range-: -800 to 800 User Range/calibration Range: -600 to500 mmH2O
3DPTPA Flow, APH PA inlet & outlet DP, secondary air flow,APH SA Inlet & Outlet DPUnit: Kpameasuring range-: -2.0 to 2.0User Range/calibration Range:0.1 to1.5
4DPTFeed Control Stn In &Out DPUnit: Mpameasuring range-:- -0.12 to10.0User Range/calibration Range:0 to 10.0
5DPTSH Spray water flowUnit: Kpa,measuring range-: -500 to 500 User Range/calibration Range:0 to 500
6DPTRH Spray Water Flow,Main Feedwater FlowUnit: Kpameasuring range-:-160 to 160 User Range/calibration Range:0 to 60
7DPTCont.blowdown tanklevel TxUnit: mmH2Omeasuring range-:-0.0 to 1500 mmH2O User Range/calibration Range:0.0 to1500
8DPTLDO Tank level TX(Capillary type)Unit: mmH2Omeasuring range-:0 to 8500, User Range/calibration Range: 0 to 8500
9DPTHFO tank level Tx( Capillary type )Unit: mmH2Omeasuring range-: 0 to 13000 User Range/calibration Range: 0 to 13000
10PTFurnace Press Tx., APH Inlet and Outlet Gas Press, ESP Intel Gas Press, ID Fan Inlet Press, Gas Press Fur. CavityUnit: Kpa,measuring range-:-8.0 to 8.0, User Range/calibration Range: -8.0to1.0
11PTMain Feedwater Press, Drum Press Tx.,SH Out Press,Main Steam Press, SH Spray water press.,Main feedwater MOV front press., Cont. blowdown tank Press. TxUnit: Mpameasuring range: -0.1 to 40.0 User Range/calibration Range: 0 to 30.0
12PTSecondary Air Pressure Tx., APH Inlet sec air press, FD FanOut Press, Furnace sec. air Box Press, Furnace PressureUnit: Kpa,measuring range-: -60 to 60 User Range/calibration Range: -7.0 to 7.0
13PTAPH out Hot PA Press, APH Inlet PA Press , mill separatoroutlet pressure ,mill Sealing air pressure, mill PA pressure scanner air outlet pressureUnit: Kpameasuring range-:-100 to 400, User Range/calibration Range:0 to 30.0
14PTID Fan Outlet PressUnit: Kpa,measuring range-:-2.0 to 2.0 User Range/calibration Range:0 to 2.0
15PTCW/ACW Header Pressure ,Instrument Air Pressure, CWoutlet pressure IAC/CAC air pressureUnit: Mpa,measuring range-:0 to 1.5User Range/calibration Range:0 to1.5
16PTRH Spray Water Press, IBD Flash tank inlet Press.Tx,Turb ,RH Spray WTR Press RH Inlet /Outlet Press Unit: Mpameasuring range-:-0.1 to 16.0 User Range/calibration Range:0 to 15.0
17PTTurbine STM PRS After Gov Stage1 Unit: Mpameasuring range-:0 to 15 User Range/calibration Range:0 to 15
18PTNo1 HPH I/L STM PRSUnit: Mpa,measuring range-:0 to 10User Range/calibration Range:0 to 10
19PTHPBP Behind STM PRS 1, HP Turb Exhaust STM LEFT PRS , HPTurb Exhaust STM Right PRS, HP Turb Exhaust STM HDR Pipe PRS ,Reater I/L STM PRS,CRH to BEPT STM PRS, RH o/LSTM Press , RH o/L STM Press , RH o/L STM Press , No2 HPHI/L STM PRS, CRH TO BFPT STM PRS, Cold RH STM To AUX STM PRS, No 2 HPH I/L STMUnit: Mpa,measuring range-:0 to 6 User Range/calibration Range: 0 to 6
20PTDearator Press 1,4 Sect. Extr. To Aux STM PRS,4 Sect. Extr. ToDea Mov FRT PRS,4# Extr. To MFPT Press,Aux STM To BFPTSTM PRS.,MFPT A I/L STM PRS.,AUX STM To BFPT STM PRS,GENSTAT CW I/L WTR Flow,No5 LPH I/L STM PRS,Turb HP&IP GasGland STM PRS. 1,GEN Entering Hydrogen Pr. No5 LPH I/L STM PRSUnit: Mpa,measuring range-: 0 to 2User Range/calibration Range:0 to 2
21PTLPBP VLV(HP) Behind STM PRS 1 LPBP VLV ( LP) Behind STM PRS 1Unit: Mpa,measuring range-:-0.2 to 2User Range/calibration Range: -0.1 to 2
22PTNo7 LPH A&B I/L STM PRSNo8 LPH A&B I/L STM PRS 1Unit: Mpameasuring range-:-0.1 to 0.1 User Range/calibration Range: -0.1 to 0.1
23PTCP INL PressUnit: Mpameasuring range-:-0.1 to 0.5 User Range/calibration Range: -0.1 to 0.5
24PTLub oil of Turb PRS Unit: Kpameasuring range-: 0 to 5500, User Range/calibration Range:0 to 5500
25PTHP Cond Vacuum Pres 1, LP Cond Vacuum Press 1, HP COND VACUUM PRS 1,LP COND VACUUM PRS 1, BFPT B Exhust vac Press, BFPT A Exhust Vac PressUnit: Kpa,measuring range-:-100 to 100 User Range/calibration Range:-100 to100
26DPTTDBFBP A I/L Filter DP, TDBFBP \"B\" I/L Filter DP TDBFBD O/L Feed WTR flow 2,TDFPA I/L Filter DP TDFP \"A\" I/L Filter DP, MBFBP I/L Filter DP, MBFP I/L Filter DP, RH Spray WTR Flow, SH Spray WTR FLOW 1, 4# Extr. To Aux STM Flow, 4# Extr. To MFPTUnit: Kpameasuring range-:-0 to 100 User Range/calibration Range:0 to 100
27PTTrub Self-Scanling Gland HTR PRSUnit: Kpameasuring range-:-100 to 600 User Range/calibration Range: -100 to 600
28DPTGEN STAT CW Flow, Seal oil DP,HP BPV IN Steam flowUnit: Kpameasuring range-:0 to 250 User Range/calibration Range:0 to 250
29DPTTDBFBP \"A\" o/L Feed WTR Flow 1,TDBFBP \"B\" O/L Feed WTR Flow1,TDBFBP B O/L Feed WTR Flow 3 MBFBP O/L Feed WTR Flow 1Unit: Kpameasuring range-:0 to 40User Range/calibration Range:0 to 40
30PTLDO , HFO SUPPLY AND RETURN PRESS(WITH CAPILLARY)Unit: Mpameasuring range-:0 to 5 User Range/calibration Range:0.1 to 5
31PTPRDS HDR PRESSUnit: Mpameasuring range-:-0 to 6.3 User Range/calibration Range:0 to 5
32PTMILL LOADING OIL PRESSUREUnit: Mpameasuring range-:0 to 40 User Range/calibration Range:0 to 25
33DPTMILL SEALING AIR DP SADC/CADC PRESS DPUnit: Kpameasuring range-:-60 to 60User Range/calibration Range:0 to 5
34DPTHFO FILTER DP(WITH CAPILLARY)Unit: Kpameasuring range-: -500 to 500 User Range/calibration Range: -100 to 100
35DPTLO FILTER DP(WITH CAPILLARY)Unit: Kpameasuring range-:-160 to 160 User Range/calibration Range:0 to 100
36DPTMILL SEPAROTOR INLET/OUTLET DPUnit: Kpameasuring range-:0 to 40 User Range/calibration Range:0 to 20
37DPTSCANNER FAN DPUnit: Kpameasuring range-: 0 to 8 User Range/calibration Range:0 to 6.2
38PTSCANNER FAN Press., Mill Separator outlet Pressure, mill seal air pressure, mill PA pressureUnit: Kpameasuring range-:-100 to 400 User Range/calibration Range:0 to 30

AI Tender Summary

OUR REF NO 37860577
AUTHORITY Government Departments
TENDER VALUE 50.21 Lakhs
LAST DATE 02-08-2023
Authority
Authority Name Rajasthan Rajya Vidyut Utpadan Nigam Limited
Work Description Supply Of Pressure Transmitter ( Pt ) And Differential Pressure Transmitter ( Dpt ) At Katpp, Jhalawar , Dpt Sh Ist & Ii Nd Stage Flow Tx, Rh Dsh Flow, Blr Cont.Blowdown Flow Unit: Kpa Measuring Range-: -500 To 500 User Range / Calibration Range:0 To 250 , Dpt Drum Level Tx. Unit: Mmh2o Measuring Range-: -800 To 800 User Range / Calibration Range: -600 To500 Mmh2o , Dpt Pa Flow, Aph Pa Inlet & Outlet Dp, Secondary Air Flow, Aph Sa Inlet & Outlet Dp Unit: Kpa Measuring Range-: -2.0 To 2.0 User Range / Calibration Range:0.1 To1.5 , Dpt Feed Control Stn In &Out Dp Unit: Mpa Measuring Range-:- -0.12 To10.0 User Range / Calibration Range:0 To 10.0 , Dpt Sh Spray Water Flow Unit: Kpa, Measuring Range-: -500 To 500 User Range / Calibration Range:0 To 500 , Dpt Rh Spray Water Flow, Main Feedwater Flow Unit: Kpa Measuring Range-:-160 To 160 User Range / Calibration Range:0 To 60 , Dpt Cont.Blowdown Tanklevel Tx Unit: Mmh2o Measuring Range-:-0.0 To 1500 Mmh2o User Range / Calibration Range:0.0 To1500 , Dpt Ldo Tank Level Tx ( Capillary Type ) Unit: Mmh2o Measuring Range-:0 To 8500, User Range / Calibration Range: 0 To 8500 , Dpt Hfo Tank Level Tx ( Capillary Type ) Unit: Mmh2o Measuring Range-: 0 To 13000 User Range / Calibration Range: 0 To 13000 , Pt Furnace Press Tx., Aph Inlet And Outlet Gas Press, Esp Intel Gas Press, Id Fan Inlet Press, Gas Press Fur. Cavity Unit: Kpa, Measuring Range-:-8.0 To 8.0, User Range / Calibration Range: -8.0To1.0 , Pt Main Feedwater Press, Drum Press Tx., Sh Out Press, Main Steam Press, Sh Spray Water Press., Main Feedwater Mov Front Press., Cont. Blowdown Tank Press. Tx Unit: Mpa Measuring Range: -0.1 To 40.0 User Range / Calibration Range: 0 To 30.0 , Pt Secondary Air Pressure Tx., Aph Inlet Sec Air Press, Fd Fan Out Press, Furnace Sec. Air Box Press, Furnace Pressure Unit: Kpa, Measuring Range-: -60 To 60 User Range / Calibration Range: -7.0 To 7.0 , Pt Aph Out Hot Pa Press, Aph Inlet Pa Press , Mill Separator Outlet Pressure , Mill Sealing Air Pressure, Mill Pa Pressure Scanner Air Outlet Pressure Unit: Kpa Measuring Range-:-100 To 400, User Range / Calibration Range:0 To 30.0 , Pt Id Fan Outlet Press Unit: Kpa, Measuring Range-:-2.0 To 2.0 User Range / Calibration Range:0 To 2.0 , Pt Cw / Acw Header Pressure , Instrument Air Pressure, Cw Outlet Pressure Iac / Cac Air Pressure Unit: Mpa, Measuring Range-:0 To 1.5 User Range / Calibration Range:0 To1.5 , Pt Rh Spray Water Press, Ibd Flash Tank Inlet Press. Tx, Turb , Rh Spray Wtr Press Rh Inlet / Outlet Press Unit: Mpa Measuring Range-:-0.1 To 16.0 User Range / Calibration Range:0 To 15.0 , Pt Turbine Stm Prs After Gov Stage1 Unit: Mpa Measuring Range-:0 To 15 User Range / Calibration Range:0 To 15 , Pt No1 Hph I / L Stm Prs Unit: Mpa, Measuring Range-:0 To 10 User Range / Calibration Range:0 To 10 , Pt Hpbp Behind Stm Prs 1, Hp Turb Exhaust Stm Left Prs , Hp Turb Exhaust Stm Right Prs, Hp Turb Exhaust Stm Hdr Pipe Prs , Reater I / L Stm Prs, Crh To Bept Stm Prs, Rh O / L Stm Press , Rh O / L Stm Press , Rh O / L Stm Press , No2 Hph I / L Stm Prs, Crh To Bfpt Stm Prs, Cold Rh Stm To Aux Stm Prs, No 2 Hph I / L Stm Unit: Mpa, Measuring Range-:0 To 6 User Range / Calibration Range: 0 To 6 , Pt Dearator Press 1, 4 Sect. Extr. To Aux Stm Prs, 4 Sect. Extr. To Dea Mov Frt Prs, 4# Extr. To Mfpt Press, Aux Stm To Bfpt Stm Prs., Mfpt A I / L Stm Prs., Aux Stm To Bfpt Stm Prs, Gen Stat Cw I / L Wtr Flow, No5 Lph I / L Stm Prs, Turb Hp&Ip Gas Gland Stm Prs. 1, Gen Entering Hydrogen Pr. No5 Lph I / L Stm Prs Unit: Mpa, Measuring Range-: 0 To 2 User Range / Calibration Range:0 To 2 , Pt Lpbp Vlv ( Hp ) Behind Stm Prs 1 Lpbp Vlv ( Lp ) Behind Stm Prs 1 Unit: Mpa, Measuring Range-:-0.2 To 2 User Range / Calibration Range: -0.1 To 2 , Pt No7 Lph A&B I / L Stm Prs No8 Lph A&B I / L Stm Prs 1 Unit: Mpa Measuring Range-:-0.1 To 0.1 User Range / Calibration Range: -0.1 To 0.1 , Pt Cp Inl Press Unit: Mpa Measuring Range-:-0.1 To 0.5 User Range / Calibration Range: -0.1 To 0.5 , Pt Lub Oil Of Turb Prs Unit: Kpa Measuring Range-: 0 To 5500, User Range / Calibration Range:0 To 5500 , Pt Hp Cond Vacuum Pres 1, Lp Cond Vacuum Press 1, Hp Cond Vacuum Prs 1, Lp Cond Vacuum Prs 1, Bfpt B Exhust Vac Press, Bfpt A Exhust Vac Press Unit: Kpa, Measuring Range-:-100 To 100 User Range / Calibration Range:-100 To100 , Dpt Tdbfbp A I / L Filter Dp, Tdbfbp B I / L Filter Dp Tdbfbd O / L Feed Wtr Flow 2, Tdfpa I / L Filter Dp Tdfp A I / L Filter Dp, Mbfbp I / L Filter Dp, Mbfp I / L Filter Dp, Rh Spray Wtr Flow, Sh Spray Wtr Flow 1, 4# Extr. To Aux Stm Flow, 4# Extr. To Mfpt Unit: Kpa Measuring Range-:-0 To 100 User Range / Calibration Range:0 To 100 , Pt Trub Self-Scanling Gland Htr Prs Unit: Kpa Measuring Range-:-100 To 600 User Range / Calibration Range: -100 To 600 , Dpt Gen Stat Cw Flow, Seal Oil Dp, Hp Bpv In Steam Flow Unit: Kpa Measuring Range-:0 To 250 User Range / Calibration Range:0 To 250 , Dpt Tdbfbp A O / L Feed Wtr Flow 1, Tdbfbp B O / L Feed Wtr Flow 1, Tdbfbp B O / L Feed Wtr Flow 3 Mbfbp O / L Feed Wtr Flow 1 Unit: Kpa Measuring Range-:0 To 40 User Range / Calibration Range:0 To 40 , Pt Ldo , Hfo Supply And Return Press ( With Capillary ) Unit: Mpa Measuring Range-:0 To 5 User Range / Calibration Range:0.1 To 5 , Pt Prds Hdr Press Unit: Mpa Measuring Range-:-0 To 6.3 User Range / Calibration Range:0 To 5 , Pt Mill Loading Oil Pressure Unit: Mpa Measuring Range-:0 To 40 User Range / Calibration Range:0 To 25 , Dpt Mill Sealing Air Dp Sadc / Cadc Press Dp Unit: Kpa Measuring Range-:-60 To 60 User Range / Calibration Range:0 To 5 , Dpt Hfo Filter Dp ( With Capillary ) Unit: Kpa Measuring Range-: -500 To 500 User Range / Calibration Range: -100 To 100 , Dpt Lo Filter Dp ( With Capillary ) Unit: Kpa Measuring Range-:-160 To 160 User Range / Calibration Range:0 To 100 , Dpt Mill Separotor Inlet / Outlet Dp Unit: Kpa Measuring Range-:0 To 40 User Range / Calibration Range:0 To 20 , Dpt Scanner Fan Dp Unit: Kpa Measuring Range-: 0 To 8 User Range / Calibration Range:0 To 6.2 , Pt Scanner Fan Press., Mill Separator Outlet Pressure, Mill Seal Air Pressure, Mill Pa Pressure Unit: Kpa Measuring Range-:-100 To 400 User Range / Calibration Range:0 To 30
Basic Detail
Tender No TN-1001(MM)
Bidding Type Tender
Location
City jhalawar
State Rajasthan
Key Dates
Publish Date 19 Jul 2023
Submission Date 02 Aug 2023
Open Date 02 Aug 2023
Finance
Tender Value 50.21 Lakhs
Tender Fee 1180
EMD 1 Lakhs
Exemption Not Available
Document List
4a9d56ce-8ce9-4a90-a5f5-ed1e94a62027.html
BOQ_599184.xls
E-TN-1001.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 19, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 05, 2023
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 19, 2023
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 02, 2023
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 02, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 02, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

4a9d56ce-8ce9-4a90-a5f5-ed1e94a62027.html

xls

BOQ_599184.xls

pdf

E-TN-1001.pdf

pdf

Tendernotice_1.pdf

TenderDetail