Rajasthan Rajya Vidyut Utpadan Nigam Limited-RVUNL has published Tender For Supply Of Pressure Transmitter (Pt) And Differential Pressure Transmitter (Dpt) At Katpp, Jhalawar. Submission Date for this Tender is 02-08-2023. Power Transformer Tenders in jhalawar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

37860577
Corrigendum : Tender For Supply Of Pressure Transmitter (Pt) And Differential Pressure Transmitter (Dpt) At Katpp, Jhalawar
Open Tender
Indian
Rajasthan
jhalawar
02-08-2023

Tender Details

Supply Of Pressure Transmitter ( Pt ) And Differential Pressure Transmitter ( Dpt ) At Katpp, Jhalawar , Dpt Sh Ist & Ii Nd Stage Flow Tx, Rh Dsh Flow, Blr Cont.Blowdown Flow Unit: Kpa Measuring Range-: -500 To 500 User Range / Calibration Range:0 To 250 , Dpt Drum Level Tx. Unit: Mmh2o Measuring Range-: -800 To 800 User Range / Calibration Range: -600 To500 Mmh2o , Dpt Pa Flow, Aph Pa Inlet & Outlet Dp, Secondary Air Flow, Aph Sa Inlet & Outlet Dp Unit: Kpa Measuring Range-: -2.0 To 2.0 User Range / Calibration Range:0.1 To1.5 , Dpt Feed Control Stn In &Out Dp Unit: Mpa Measuring Range-:- -0.12 To10.0 User Range / Calibration Range:0 To 10.0 , Dpt Sh Spray Water Flow Unit: Kpa, Measuring Range-: -500 To 500 User Range / Calibration Range:0 To 500 , Dpt Rh Spray Water Flow, Main Feedwater Flow Unit: Kpa Measuring Range-:-160 To 160 User Range / Calibration Range:0 To 60 , Dpt Cont.Blowdown Tanklevel Tx Unit: Mmh2o Measuring Range-:-0.0 To 1500 Mmh2o User Range / Calibration Range:0.0 To1500 , Dpt Ldo Tank Level Tx ( Capillary Type ) Unit: Mmh2o Measuring Range-:0 To 8500, User Range / Calibration Range: 0 To 8500 , Dpt Hfo Tank Level Tx ( Capillary Type ) Unit: Mmh2o Measuring Range-: 0 To 13000 User Range / Calibration Range: 0 To 13000 , Pt Furnace Press Tx., Aph Inlet And Outlet Gas Press, Esp Intel Gas Press, Id Fan Inlet Press, Gas Press Fur. Cavity Unit: Kpa, Measuring Range-:-8.0 To 8.0, User Range / Calibration Range: -8.0To1.0 , Pt Main Feedwater Press, Drum Press Tx., Sh Out Press, Main Steam Press, Sh Spray Water Press., Main Feedwater Mov Front Press., Cont. Blowdown Tank Press. Tx Unit: Mpa Measuring Range: -0.1 To 40.0 User Range / Calibration Range: 0 To 30.0 , Pt Secondary Air Pressure Tx., Aph Inlet Sec Air Press, Fd Fan Out Press, Furnace Sec. Air Box Press, Furnace Pressure Unit: Kpa, Measuring Range-: -60 To 60 User Range / Calibration Range: -7.0 To 7.0 , Pt Aph Out Hot Pa Press, Aph Inlet Pa Press , Mill Separator Outlet Pressure , Mill Sealing Air Pressure, Mill Pa Pressure Scanner Air Outlet Pressure Unit: Kpa Measuring Range-:-100 To 400, User Range / Calibration Range:0 To 30.0 , Pt Id Fan Outlet Press Unit: Kpa, Measuring Range-:-2.0 To 2.0 User Range / Calibration Range:0 To 2.0 , Pt Cw / Acw Header Pressure , Instrument Air Pressure, Cw Outlet Pressure Iac / Cac Air Pressure Unit: Mpa, Measuring Range-:0 To 1.5 User Range / Calibration Range:0 To1.5 , Pt Rh Spray Water Press, Ibd Flash Tank Inlet Press. Tx, Turb , Rh Spray Wtr Press Rh Inlet / Outlet Press Unit: Mpa Measuring Range-:-0.1 To 16.0 User Range / Calibration Range:0 To 15.0 , Pt Turbine Stm Prs After Gov Stage1 Unit: Mpa Measuring Range-:0 To 15 User Range / Calibration Range:0 To 15 , Pt No1 Hph I / L Stm Prs Unit: Mpa, Measuring Range-:0 To 10 User Range / Calibration Range:0 To 10 , Pt Hpbp Behind Stm Prs 1, Hp Turb Exhaust Stm Left Prs , Hp Turb Exhaust Stm Right Prs, Hp Turb Exhaust Stm Hdr Pipe Prs , Reater I / L Stm Prs, Crh To Bept Stm Prs, Rh O / L Stm Press , Rh O / L Stm Press , Rh O / L Stm Press , No2 Hph I / L Stm Prs, Crh To Bfpt Stm Prs, Cold Rh Stm To Aux Stm Prs, No 2 Hph I / L Stm Unit: Mpa, Measuring Range-:0 To 6 User Range / Calibration Range: 0 To 6 , Pt Dearator Press 1, 4 Sect. Extr. To Aux Stm Prs, 4 Sect. Extr. To Dea Mov Frt Prs, 4# Extr. To Mfpt Press, Aux Stm To Bfpt Stm Prs., Mfpt A I / L Stm Prs., Aux Stm To Bfpt Stm Prs, Gen Stat Cw I / L Wtr Flow, No5 Lph I / L Stm Prs, Turb Hp&Ip Gas Gland Stm Prs. 1, Gen Entering Hydrogen Pr. No5 Lph I / L Stm Prs Unit: Mpa, Measuring Range-: 0 To 2 User Range / Calibration Range:0 To 2 , Pt Lpbp Vlv ( Hp ) Behind Stm Prs 1 Lpbp Vlv ( Lp ) Behind Stm Prs 1 Unit: Mpa, Measuring Range-:-0.2 To 2 User Range / Calibration Range: -0.1 To 2 , Pt No7 Lph A&B I / L Stm Prs No8 Lph A&B I / L Stm Prs 1 Unit: Mpa Measuring Range-:-0.1 To 0.1 User Range / Calibration Range: -0.1 To 0.1 , Pt Cp Inl Press Unit: Mpa Measuring Range-:-0.1 To 0.5 User Range / Calibration Range: -0.1 To 0.5 , Pt Lub Oil Of Turb Prs Unit: Kpa Measuring Range-: 0 To 5500, User Range / Calibration Range:0 To 5500 , Pt Hp Cond Vacuum Pres 1, Lp Cond Vacuum Press 1, Hp Cond Vacuum Prs 1, Lp Cond Vacuum Prs 1, Bfpt B Exhust Vac Press, Bfpt A Exhust Vac Press Unit: Kpa, Measuring Range-:-100 To 100 User Range / Calibration Range:-100 To100 , Dpt Tdbfbp A I / L Filter Dp, Tdbfbp B I / L Filter Dp Tdbfbd O / L Feed Wtr Flow 2, Tdfpa I / L Filter Dp Tdfp A I / L Filter Dp, Mbfbp I / L Filter Dp, Mbfp I / L Filter Dp, Rh Spray Wtr Flow, Sh Spray Wtr Flow 1, 4# Extr. To Aux Stm Flow, 4# Extr. To Mfpt Unit: Kpa Measuring Range-:-0 To 100 User Range / Calibration Range:0 To 100 , Pt Trub Self-Scanling Gland Htr Prs Unit: Kpa Measuring Range-:-100 To 600 User Range / Calibration Range: -100 To 600 , Dpt Gen Stat Cw Flow, Seal Oil Dp, Hp Bpv In Steam Flow Unit: Kpa Measuring Range-:0 To 250 User Range / Calibration Range:0 To 250 , Dpt Tdbfbp A O / L Feed Wtr Flow 1, Tdbfbp B O / L Feed Wtr Flow 1, Tdbfbp B O / L Feed Wtr Flow 3 Mbfbp O / L Feed Wtr Flow 1 Unit: Kpa Measuring Range-:0 To 40 User Range / Calibration Range:0 To 40 , Pt Ldo , Hfo Supply And Return Press ( With Capillary ) Unit: Mpa Measuring Range-:0 To 5 User Range / Calibration Range:0.1 To 5 , Pt Prds Hdr Press Unit: Mpa Measuring Range-:-0 To 6.3 User Range / Calibration Range:0 To 5 , Pt Mill Loading Oil Pressure Unit: Mpa Measuring Range-:0 To 40 User Range / Calibration Range:0 To 25 , Dpt Mill Sealing Air Dp Sadc / Cadc Press Dp Unit: Kpa Measuring Range-:-60 To 60 User Range / Calibration Range:0 To 5 , Dpt Hfo Filter Dp ( With Capillary ) Unit: Kpa Measuring Range-: -500 To 500 User Range / Calibration Range: -100 To 100 , Dpt Lo Filter Dp ( With Capillary ) Unit: Kpa Measuring Range-:-160 To 160 User Range / Calibration Range:0 To 100 , Dpt Mill Separotor Inlet / Outlet Dp Unit: Kpa Measuring Range-:0 To 40 User Range / Calibration Range:0 To 20 , Dpt Scanner Fan Dp Unit: Kpa Measuring Range-: 0 To 8 User Range / Calibration Range:0 To 6.2 , Pt Scanner Fan Press., Mill Separator Outlet Pressure, Mill Seal Air Pressure, Mill Pa Pressure Unit: Kpa Measuring Range-:-100 To 400 User Range / Calibration Range:0 To 30

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Jun-2023 CORRIGENDUM-I Date 05-07-2023
2 05-Jul-2023 NIT EXTENSION ORDER-II Date 19-07-2023
3 19-Jul-2023 NIT Extension Order IIIrd Date 02-08-2023

Key Value

Document Fees
INR 1180 /-
EMD
INR 100420.0 /-
Tender Value
INR 50.21 Lakhs /-

BOQ Items

Name of Work: < SUPPLY OF PRESSURE TRANSMITTER (PT) AND DIFFERENTIAL PRESSURE TRANSMITTER (DPT)AT KATPP, RVUNL, JHALAWAR.>
Sl. No. Item Description
1DPT SH Ist & II nd stage Flow tx,RH DSH Flow,BLR Cont.blowdown Flow Unit: Kpa measuring range-: -500 to 500 User Range/calibration Range:0 to 250
2DPT Drum Level Tx. Unit: mmH2O measuring range-: -800 to 800 User Range/calibration Range: -600 to500 mmH2O
3DPT PA Flow, APH PA inlet & outlet DP, secondary air flow, APH SA Inlet & Outlet DP Unit: Kpa measuring range-: -2.0 to 2.0 User Range/calibration Range:0.1 to1.5
4DPT Feed Control Stn In &Out DP Unit: Mpa measuring range-:- -0.12 to10.0 User Range/calibration Range:0 to 10.0
5DPT SH Spray water flow Unit: Kpa, measuring range-: -500 to 500 User Range/calibration Range:0 to 500
6DPT RH Spray Water Flow,Main Feedwater Flow Unit: Kpa measuring range-:-160 to 160 User Range/calibration Range:0 to 60
7DPT Cont.blowdown tanklevel Tx Unit: mmH2O measuring range-:-0.0 to 1500 mmH2O User Range/calibration Range:0.0 to1500
8DPT LDO Tank level TX (Capillary type) Unit: mmH2O measuring range-:0 to 8500, User Range/calibration Range: 0 to 8500
9DPT HFO tank level Tx ( Capillary type ) Unit: mmH2O measuring range-: 0 to 13000 User Range/calibration Range: 0 to 13000
10PT Furnace Press Tx., APH Inlet and Outlet Gas Press, ESP Intel Gas Press, ID Fan Inlet Press, Gas Press Fur. Cavity Unit: Kpa, measuring range-:-8.0 to 8.0, User Range/calibration Range: -8.0to1.0
11PT Main Feedwater Press, Drum Press Tx.,SH Out Press, Main Steam Press, SH Spray water press.,Main feedwater MOV front press., Cont. blowdown tank Press. Tx Unit: Mpa measuring range: -0.1 to 40.0 User Range/calibration Range: 0 to 30.0
12PT Secondary Air Pressure Tx., APH Inlet sec air press, FD Fan Out Press, Furnace sec. air Box Press, Furnace Pressure Unit: Kpa, measuring range-: -60 to 60 User Range/calibration Range: -7.0 to 7.0
13PT APH out Hot PA Press, APH Inlet PA Press , mill separator outlet pressure ,mill Sealing air pressure, mill PA pressure scanner air outlet pressure Unit: Kpa measuring range-:-100 to 400, User Range/calibration Range:0 to 30.0
14PT ID Fan Outlet Press Unit: Kpa, measuring range-:-2.0 to 2.0 User Range/calibration Range:0 to 2.0
15PT CW/ACW Header Pressure ,Instrument Air Pressure, CW outlet pressure IAC/CAC air pressure Unit: Mpa, measuring range-:0 to 1.5 User Range/calibration Range:0 to1.5
16PT RH Spray Water Press, IBD Flash tank inlet Press. Tx,Turb ,RH Spray WTR Press RH Inlet /Outlet Press Unit: Mpa measuring range-:-0.1 to 16.0 User Range/calibration Range:0 to 15.0
17PT Turbine STM PRS After Gov Stage1 Unit: Mpa measuring range-:0 to 15 User Range/calibration Range:0 to 15
18PT No1 HPH I/L STM PRS Unit: Mpa, measuring range-:0 to 10 User Range/calibration Range:0 to 10
19PT HPBP Behind STM PRS 1, HP Turb Exhaust STM LEFT PRS , HP Turb Exhaust STM Right PRS, HP Turb Exhaust STM HDR Pipe PRS ,Reater I/L STM PRS,CRH to BEPT STM PRS, RH o/L STM Press , RH o/L STM Press , RH o/L STM Press , No2 HPH I/L STM PRS, CRH TO BFPT STM PRS, Cold RH STM To AUX STM PRS, No 2 HPH I/L STM Unit: Mpa, measuring range-:0 to 6 User Range/calibration Range: 0 to 6
20PT Dearator Press 1,4 Sect. Extr. To Aux STM PRS,4 Sect. Extr. To Dea Mov FRT PRS,4# Extr. To MFPT Press,Aux STM To BFPT STM PRS.,MFPT A I/L STM PRS.,AUX STM To BFPT STM PRS,GEN STAT CW I/L WTR Flow,No5 LPH I/L STM PRS,Turb HP&IP Gas Gland STM PRS. 1,GEN Entering Hydrogen Pr. No5 LPH I/L STM PRS Unit: Mpa, measuring range-: 0 to 2 User Range/calibration Range:0 to 2
21PT LPBP VLV(HP) Behind STM PRS 1 LPBP VLV ( LP) Behind STM PRS 1 Unit: Mpa, measuring range-:-0.2 to 2 User Range/calibration Range: -0.1 to 2
22PT No7 LPH A&B I/L STM PRS No8 LPH A&B I/L STM PRS 1 Unit: Mpa measuring range-:-0.1 to 0.1 User Range/calibration Range: -0.1 to 0.1
23PT CP INL Press Unit: Mpa measuring range-:-0.1 to 0.5 User Range/calibration Range: -0.1 to 0.5
24PT Lub oil of Turb PRS Unit: Kpa measuring range-: 0 to 5500, User Range/calibration Range:0 to 5500
25PT HP Cond Vacuum Pres 1, LP Cond Vacuum Press 1, HP COND VACUUM PRS 1,LP COND VACUUM PRS 1, BFPT B Exhust vac Press, BFPT A Exhust Vac Press Unit: Kpa, measuring range-:-100 to 100 User Range/calibration Range:-100 to100
26DPT TDBFBP A I/L Filter DP, TDBFBP "B" I/L Filter DP TDBFBD O/L Feed WTR flow 2,TDFPA I/L Filter DP TDFP "A" I/L Filter DP, MBFBP I/L Filter DP, MBFP I/L Filter DP, RH Spray WTR Flow, SH Spray WTR FLOW 1, 4# Extr. To Aux STM Flow, 4# Extr. To MFPT Unit: Kpa measuring range-:-0 to 100 User Range/calibration Range:0 to 100
27PT Trub Self-Scanling Gland HTR PRS Unit: Kpa measuring range-:-100 to 600 User Range/calibration Range: -100 to 600
28DPT GEN STAT CW Flow, Seal oil DP,HP BPV IN Steam flow Unit: Kpa measuring range-:0 to 250 User Range/calibration Range:0 to 250
29DPT TDBFBP "A" o/L Feed WTR Flow 1,TDBFBP "B" O/L Feed WTR Flow 1,TDBFBP B O/L Feed WTR Flow 3 MBFBP O/L Feed WTR Flow 1 Unit: Kpa measuring range-:0 to 40 User Range/calibration Range:0 to 40
30PT LDO , HFO SUPPLY AND RETURN PRESS (WITH CAPILLARY) Unit: Mpa measuring range-:0 to 5 User Range/calibration Range:0.1 to 5
31PT PRDS HDR PRESS Unit: Mpa measuring range-:-0 to 6.3 User Range/calibration Range:0 to 5
32PT MILL LOADING OIL PRESSURE Unit: Mpa measuring range-:0 to 40 User Range/calibration Range:0 to 25
33DPT MILL SEALING AIR DP SADC/CADC PRESS DP Unit: Kpa measuring range-:-60 to 60 User Range/calibration Range:0 to 5
34DPT HFO FILTER DP (WITH CAPILLARY) Unit: Kpa measuring range-: -500 to 500 User Range/calibration Range: -100 to 100
35DPT LO FILTER DP (WITH CAPILLARY) Unit: Kpa measuring range-:-160 to 160 User Range/calibration Range:0 to 100
36DPT MILL SEPAROTOR INLET/OUTLET DP Unit: Kpa measuring range-:0 to 40 User Range/calibration Range:0 to 20
37DPT SCANNER FAN DP Unit: Kpa measuring range-: 0 to 8 User Range/calibration Range:0 to 6.2
38PT SCANNER FAN Press., Mill Separator outlet Pressure, mill seal air pressure, mill PA pressure Unit: Kpa measuring range-:-100 to 400 User Range/calibration Range:0 to 30