| 1 | Taking out old unserviceable cable of any size carefully from trenches ofter disconnecting electric connection, GI pipe protection, with and including separating serviceable bricks & set aside and removing un-serviceable bricks from site complete all as specified and as directed.Note : The excavation and earth work shall be measured and paid separately under relevant items of schedule. |
| 2 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulatedPVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 16 sqmm 2 core with and including all fixing & connecting accessories such as Aluminum cable lugs, cable gland, nut, bolts, washer etc complete all as specified and as directed.Note :GI protection pipe, bricks protection and sand cushioning shall be measured and paid separately. |
| 3 | All as per ser item No 2 above but of cross sectional area 16 sqmm 4 core complete all as specified and as directed. |
| 4 | All as per ser item No 2 above but of cross sectional area 25 sqmm 4 core complete all as specified and as directed. |
| 5 | All as per ser item No 2 above but of cross sectional area 50 sqmm 3.5 core complete all as specified and as directed. |
| 6 | Digging out incoming and outgoing cables of any sizes from loops near junction box/ feeder pillar box in trenches, cutting burnt out uninsulated portion of cable and relaying /refixing in trenches & returning, refilling the excavated soil and connecting the cables with bus bars including provision of suitable size of aluminium lugs complete all as specified and as directed.Note : Earth work and its connected items shall be included in the item and bidders shall quote the rate accordingly. |
| 7 | Relaying in trenches or passing through pipe, 1100 volts grade,LT electric power UG cables, of any type/Size with and including all fixing & connecting accessories such as Aluminum cable lugs, cable gland, nut, bolts, washer etc complete all as specified and as directed.Note : The serviceable cable obtained from taking out vide item No. 1 shall be reused.The items GI pipes, bricks and sand cushioning shall be measured and paid separately. |
| 8 | Supply and fix of moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 63 Amps of breaking capacity 25 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 9 | Supply and fix ofmoulded case circuit breaker (MCCB) four pole Microprocessor release type 415 volt, 50 Cycles, 100 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 10 | Supply and fix ofmoulded case circuit breaker (MCCB) four pole Microprocessor release 415 volt, 50 Cycles, 160 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 11 | Supply and fix ofmoulded case circuit breaker (MCCB) four pole Microprocessor release type 415 volt, 50 Cycles, 200 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 12 | Supply and fix ofmoulded case circuit breaker (MCCB) four pole Microprocessor release type 415 volt, 50 Cycles, 250 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 13 | Supply and fix moulded case circuit breaker (MCCB) four pole Microprocessor release type 415 volt, 50 Cycles, 400 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 14 | S&F in replacement MCB, Triple pole & neutral 63 amps, 240 volts, ‘C’ curve, 10KAcomplete all as specified and as directed. |
| 15 | M&L for heat shrinkable straight through joint for 3.5 / 4 core cable 25sqmm to 50 sqmm complete all as specified and as directed. |
| 16 | Excavation in trenches in soft/loose soil not exc. 1.5 meter wide and not exc. 1.5 meter in depth and getting out for taking up / layingunder ground electric cable complete all as specified and as directed. |
| 17 | Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cms in depth complete all as specified and as directed. |
| 18 | Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 19 | Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. |
| 20 | Supply and laying sub class B bricks of size 23cmx12.5cmx7.5cm (+/-10% tolerance) for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed. |
| 21 | Laying only Old bricks for protection of LT UG cable complete all as specified and as directed. Note: The serviceable bricks obtained from item Ser No. 1 shall be reused. |
| 22 | M & L for horizontal boring suitable for 50mm bore steel tubing across the existing road without disturbing the road surface for insertingGI pipe complete all as specified and as directed. Notes:- (i) Removal of surplus soil shall be deemed to be include in the unit Rate. (ii) GI pipe will be measured and paid separately under relevant item of Sch \"A\". |
| 23 | M&L for 50 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed. |
| 24 | M&L for one run of 6 Sqmm 2 Core (Nominal Area) PVC Sheathed multi stranded unarmed aluminium conductor cable LT 1100 volt grade Conforming to IS 7098 FRLS (inner sheet) in existing position including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 25 | M&L for one run of 10 Sqmm 2 Core (Nominal Area) PVC Sheathed multi stranded unarmed aluminium conductor cable LT 1100 volt grade conforming to IS 7098 FRLS (inner sheet) in existing position including taking down / dismantling of old existing unserviceable one complete all as specified and as directed. |
| 26 | Dismantling of old unserviceable LT feeder pillar box/LT junction box including PCC/Brick work foundation after disconnecting of all electrical connection complete all as specified and as directed. |
| 27 | Supply, fabrication, installation and testing of LT out door type factory made CPRI approved, junction box of size 900mmX600mmX400mm (over all dimension) made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 25X25X5mm vertical frame and legs with mild steel flat iron 25X5 mm in horizontal sides of the frame with front and back side open able ,single hinged door / shutter with locking arrangement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of size 0.80m X 0.6m X 0.90m depth (0.30m below ground level and 0.60m above ground level ) and connections of all outgoing / incoming existing cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables including the following fitment accessories all complete as specified and as directed.(a)Copperbus bar of size 600 Amp wrapped with PVC sleeves with maintained the colour code and provision of making holes as required with nuts, bolts & washers for cable connections including hydrographic insulators with nuts & bolts at both ends= 04 nos.(b)Synthetic enameled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. |
| 28 | Supply, fabrication, installation, testing and commissioning of LT 3 Phase 4 wire 450 Volts system, factory made CPRI approved water and vermin proof protection pedestal type feeder pillar box (CPRI approved) of minimum size 1200 mm x 800 mm x 500 mm (overall) of out door type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side open able hinged door and air ventilation arrangement including provision of cable looping box of size 800 x 450 x 400 mm . Danger notice plate with letters, figures and conventional skull and bones in signal red and shall be fixed on main door. The panel shall be complete painted with Powder Coated paint of approved shade. \"U\" type gas ket shall be used to make the inner shell completely vermin proof to accommodate incomers/outgoing MCCBs. All interconnection between the main bus bar as well as out going feeders shall be carried out with TPN coppe bus bar of rating not less than 1.5 times the rated capacity of individual out going feeders and should be insulated with heat shreank cable PVC shleaves and shall be mounted on suitable size \"F\" class insulators. The degree of protection of outer shell of the panel shall be IP-65. A detachable pre drilled gland plate should be used at bottom. All control wire shall be with 2.5 sqmm multi stranded copper conductors and shall be properly brunched, tied, ferruled for proper identification and print with adequate size of lugs complete with and including PCC (1:3:6) type C-2 of size 0.80 m x 0.60 m x 1.05 m depth (45 cm below ground level and 60 cm above ground level) as in foundation in cement mortar 1:6 and plastering the same in cement mortar 1 : 6 finished even and smooth with out using extra cement complete including necessary excavation, earth work and including connecting all incoming and outgoing LT UG cables after drawing/ digging out cable from loops in trenches complete all as specified and as directed along with and including comprising of the following accessories : - (a)Copper busbar 600 Amps capacity including insulator with nuts & bolts-04 Nos (Incoming) (b)Copper busbar 400 Amps capacity including insulator with nuts & bolts-04 Nos ( Out going) (c) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 160 amps including all fixing accessories with both ends spreader links . ( Incoming -01 Nos) (d) MCCB 4 pole, 415 volts, 25 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 63 amps including all fixing accessories with both ends spreader links . ( Outgoing -04 Nos) (e) MCB SPN 40 Amps 240 volts 10 KA - 4 Nos (f)Neon indicator lamp with holder (RYB) = 03 Nos (g) Digital Voltmeter of range (0-500) volt flush mounting type with selector switch = 01 No (h) Digital Ammeter of range (0-200) Amp flush mounting type with selector switch = 01 No (i) Enameled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of FPB for LT -01 No.Note : (i) Cost of earth work and PCC are deemed to be inclusive in this item.(ii) the schematic diag of LT panels shall be approved by GE before procurement. |
| 29 | Supply and fixing aluminium strip of size 25 x 3mm for earth continuity conductor fixed on PCC block complete all as specified as directed complete all as specified and as directed. |
| 30 | Supply and fixing Copper strip of size 20 x 3mm for earth continuity conductor fixed on PCC block complete all as specified as directed complete all as specified and as directed. |
| 31 | Dismantling of existing unserviceable loose/disturbed Aluminum strip/Copper strip/GI Strip/Termination rod of any sizes on roof/down conductor fixed on wooden guities /directly on roof including screws etc complete all as specified and as directed. |
| 32 | Supply & fixing in repairsfor 32 x 6 mm galvanised iron strip, earth continuity conductor or main earthling lead fixed to wall on batten or recess or chases or buried in ground or fixed to poles or roof with saddle and screw current complete all as specified and as directed. |
| 33 | Supply and fixing porcelain insulator of size 65x31 mm and height 30mm with three nos hole including GI bolts and nuts of required size and two nos washer on PCC, fixing strip complete all as specified and as directed. |
| 34 | M & L for PCC work providing PCC type C1 (1 :3 : 6 ) with 20 mm graded aggregate in foundation for panel/coping and finishing the surface even and smooth without using extra cement including breaking of old PCC and necessary form work complete all as specified and as directed. |
| 35 | Disconnecting electric connection and Taking down of all UG cable from LT Panel/JB of any capacity and model removing of unserviceable spares / accessories for repair/replacement of the same including reconnection of all UG Cable connection with suitable lugs, nuts & bolts etc to existing LT Panel/JB and testing complete all as specified and as directed. Note: Suitable lugs, nuts & bolts etc for reconnection shall be deemed including in quoted rate. |
| 36 | M & L for GI tubing, 20 mm dia bore, Light grade with all fittings laid in trenches including taking down of existing pipes and removal from site complete all as specified and as directed. |
| 37 | M & Lin repairs Earth continuity conductor or main earthling lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles/Bldg/panel or any other indicated situation for loop earthling etc. as required 4.00 mm dia galvanised iron or steel wire complete all as specified and as directed |
| 38 | Taking down old unserviceable Earthing pit of any type with accessories including removing of demolished material from work site at distance n.exc 500m out side MD land complete all as specified and as directed. |
| 39 | M&L for Earthing complete with Copper earth plate electrode 600x600x3.15 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below the ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to Copper earth strip 20x3 mm dia by means of bolts, nuts, check nuts and washers of brass/copper all as shown in electrical plate No 3 of SSR part-I2009 connected to lightening conductor all as specified and testing on completion including necessary excavation, earthwork, PCC works and CI earth pit cover with watering pipe 20mm dia GI pipe medium grade, funnel with wire mesh and lugs and GI pipe 40 mm dia of light grade,for protection of earth stripcomplete all as specified and directed. |
| 40 | M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below the ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or of steel all as shown in electrical plate No 3 of SSR part-I2009 connected to pole/LT Panel all as specified and testing on completion including necessary excavation, earthwork, PCC works and CI earth pit cover with watering pipe 20mm dia GI pipe medium grade, funnel with wire mesh and lugs and GI pipe 40 mm dia of light grade,for protection of earth stripcomplete all as specified and directed. |
| 41 | M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below the ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or of steel all as shown in electrical plate No 3 of SSR part-I2009 connected to pole/LT Panel all as specified and testing on completion including necessary excavation, earthwork, PCC works and CI earth pit cover with watering pipe 20mm dia GI pipe medium grade, funnel with wire mesh and lugs and GI pipe 40 mm dia of light grade,for protection of earth stripcomplete all as specified and directed. |
| 42 | Supply, laying ,jointing andtestingLT underground electric power cable crossed linked XLPE insulated, two or more core galvanized steel strip or wire armoured / PVC insulated armoured cableheavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 10 sqmm 2 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts or passing through pipesetc fixing and connecting accessories such as Aluminium cable lugs, cable glands, nut, bolts, washwers etc complete all as specified and as directed.Note :GI protection pipe, bricks protection and sand cushioning shall be measured and paid separately. |
| 43 | Supply and fixing in repairs street light bracket made out of GI pipe light grade 40 mm dia 1.2 mtr length bent to shape and reduced to required size at top upto 1.5 mtr length by cutting, welding and well finishing including MS clamp of flat iron of size 40 x 6 mm suitable length 2 Nos complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats aluminium paint over a coat of red oxide primer complete all as specified and as directed. |
| 44 | Material and labour for LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs with lens and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-270 Volts, delivering lumen equal to/greater than 4500 lumen, system wattage 45 Watt, Ingress protection IP-66 with all accessories including taking down unserviceable light fitting and removing from site complete all as specified and as directed. |
| 45 | Material and labour for LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs with lens and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-270 Volts, delivering lumen equal to/greater than 6000 lumen, system wattage 60 Watt, Ingress protection IP-66 with all accessories including taking down unserviceable light fitting and removing from site complete all as specified and as directed. |
| 46 | Material and labour for LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs with lens and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-270 Volts, delivering lumen equal to/greater than 9000 lumen, system wattage 90 Watt, Ingress protection IP-66 with all accessories including taking down unserviceable light fitting and removing from site complete all as specified and as directed. |
| 47 | Material and labour for LED floodlight epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs with lens and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-270 Volts, delivering lumen equal to/greater than 10000 lumen, system wattage 100 Watt, Ingress protection IP-66 with all accessories including taking down unserviceable light fitting and removing from site complete all as specified and as directed. |
| 48 | Material and labour for LED floodlight epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs with lens and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-270 Volts, delivering lumen equal to/greater than 20000 lumen, system wattage 200 Watt, Ingress protection IP-66 with all accessories including taking down unserviceable light fitting and removing from site complete all as specified and as directed. |
| 49 | M&L for LED garden light 09 watt made up of high grade unbreakable polycarbonate material, IP-65 protection, cone series innovative design with uniformly lit diffuser at the upper portion inlc taking out old unsv garden light fittings complete all as specified and as directed. |
| 50 | Supply and fixing loop in- loop out fuse junction box of internal dimention 250 x 200 x 100mm made of FRP sheet with weather proof canopy and locking screw fitted with and including50 Amp rated 4 way connectors for 3 phase and neutral incoming/outgoing , mounted in the box, fixing on street pole/rail poles including necessary aluminium clamps, suitable glands, lugs and GI nut and bolt including taking down old unserviceable junction box complete all as specified and as directed.Note: Contractor shall provide cable lugs andPVC gland of suitable size if required on site for connecting cable in junction box. |
| 51 | Supplying and fixing in repairs single run 3 core ,2.50 sqmm nominal cross sectional areamultistrandedcopper conductor cable, over all PVC sheathed, 1100 Volts grade confirming to IS-694-2010 (FRLS) heavy dutycable PVC insulatedand PVC sheathed from pole junction box to light fitting complete all as specified. |
| 52 | Supplying and fixing in repairs single run 2 core ,1.50 sqmm nominal cross sectional areamultistrandedcopper conductor cable, over all PVC sheathed, 1100 Volts grade confirming to IS-694-2010 (FRLS) heavy dutycable PVC insulatedand PVC sheathed from pole junction box to light fitting complete all as specified. |
| 53 | Supply and fixed in repairs 20 mm nominal bore dia, UPVC pipes of pressure rating 10 kgf/cm2 fixed to pole, any type including provision MS clamp of size 20mm x 3mm flat at interval of 1.5 m length complete all as specified and as directed |
| 54 | Supply and fixing in repairs power contractor 40 amps 3 pole ( 1NO + 1 NC) , 415 Volts AC 50Hz,including connecting with existing system complete all as specified and directed. |
| 55 | Supply and fixed in repairs of Digital Time switch(5-40) Amps , 240 Volts , AC , Singlephase complete all as specified and as directed. |
| 56 | Material and labour for disconnection of all electric connection and taking down of street light fittings of any type , size , capacity and model removing of unserviceable spares or accessories for repair/ replacement of the same including reconnecting and refixing of street light to its existing position viz pole / high mast andtesting complete all as specified and as directed.Note : The unit rate quoted shall be deemed inclusive for the following nature of work. A BOO shall be assembled for deciding the spares to be changed and paid against supply only items:-(a) Contractor shall be provided one Skilled Electrician and 2(Two) Helper alongwith T&P and wooden ladder.(b) SparesParts required for repair will be measured and paid separately as supply only under relevant items of this schedule. |
| 57 | Supply and fixing in repairsElectronic driver suitable for 45 Watts LED Street light fittings of approved make / brand complete all as specified and as directed. |
| 58 | Supply and fixing in repairs Electronic driver suitable for 60 Watts LED Street light fittings of approved make / brand complete all as specified and as directed. |
| 59 | Supply installation and testingof outdoor time line distribution board forstreet light , degree of protection IP 54, three phase, maximum load 12 kW, prewired with Digital timer switch, contactor TP rating 65 Amp and MCB Triple pole & neutral rating 63 Amp complete all as specified and as directed. |
| 60 | Material and labour for steel tubular poles complete with cast iron base palate, final taper plug bolts, nuts & screws as specified type 410 SP-31, 9.0 meter long including painting all external exposed steel surfaces with two coats of aluminum paints over a coat of red oxide zinc chrome primer and all internal surfaces and external surfaces in contact with concrete with two coats of black bituminous paint complete all as specified and as directed including taking down old existing concrete poles / struts any size after demolition of foundation and depositing / stackingat a place where directed within 5kM distance from the work site complete all as specified and as directed. |
| 61 | M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate for foundation of stay assembly/struts/pole etc. (around the poles in pit) complete all as specified and as directed. |
| 62 | M & L Painting ofsteel pole (swan neck type or straight type) up to 12 mtr heightwith cross arms, clamp of any length and shape for LT overhead line/ for street lightwith two coat of aluminium paint after scratching out old paint, cleaning and exiting surface rust free, preparation of the existing surface,including marking pole numbers in a 15 cm dia yellow circle with number writing with blacksyenthic paint/ Sticker, includingpainting strips in alternate from bottom to top with three strips of black syntheticpaint & two strips of Yellow/ Red paint(as per existing pattern through out the circumference of pole, including removing extra wall papdi ,peel off wall papdi by sand paper and makinggood with putty as per existing thickness and applying one coat of white washing on PCC copping of pole and re-numbering of pole with approved size of letter ( Example - CZ- 001) with synthetic enamel paint of white colour background and black colour lettering complete all as specified and as directed. |
| 63 | M&L for repairing of mechanism of lowering down and hoisting of flood light cage (mobile Head frame) of High mast assy of 16 mtr height, repairing, servicing of hoisting motor assy, repairing of chain, greasing of moving parts and replacement of steel rope, pulley ,repairing of elevator wrench system etc, relaying of rope from top to bottom and making the mechanism functional complete all as specified and as directed. |
| 64 | M&L for winding of induction motor of single phase, 1 HP, 240 V, 50 Hzof High mast of hoisting and lowering mechanism of flood light cage with super enameled winding wire of existing gaudge , replacement of bearing as per existing etc to make the motor functional complete all as specified and as directed. |
| 65 | M&L for repairing of Control Panel of Hight mast assy, repair/replacement of unserviceableparts like MCB, Contractor, auto manual switch, NO + NC switch, starter motor, replacement of u/sindicators, start stop switch , repairing and complete wiring of panel with min 1.5 Sqmm wire complete all as specified and as directed.Note: Cost of spares replaced shall be paid under relevant item of this schedule as supply only. |
| 66 | Supply only 4 Pole Power contractor Type MCX, AC 1 rating 40Amp,415 V, 50Hzcomplete all as specified and as directed. |
| 67 | Supply only digital time switch 240V complete all as specified and as directed. |
| 68 | Material and labour for removing old painted surface and apply two coats of exterior acrylic emulsion paintabrasion resistance, corrosion resistance, excellent adhesion with superior finish over a coat of exterior grade white primer to PCC pole 9.00/9.50 mtr long including cross arms/street light bracket after preparation of existing painted surface including marking the strips of one feet each on pole with red and white exterior acrylic emulsion paint two coat upto 6 feet from the bottom of pole (Total 6 Nos strip of one feet each) and re-numbering of pole with approved size of letter (Example : CZ- 001) with synthetic enamel paint on black colour background and white colour lettering completeall as specified and directed . |