Tender For Repair/ Maint Of Internal Electrification Fittings, Fixture, Main Distributing Boards, Bldg Earthing, Internal Electric Supply Services And Other E/M Works In Omq, Otm Accn And Technical Area, sulur-Tamil Nadu

Military Engineer Services-MES has published Tender For Repair/ Maint Of Internal Electrification Fittings, Fixture, Main Distributing Boards, Bldg Earthing, Internal Electric Supply Services And Other E/M Works In Omq, Otm Accn And Technical Area. Submission Date for this Tender is 14-06-2023. Electrification Work Tenders in sulur Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

37850754
Tender For Repair/ Maint Of Internal Electrification Fittings, Fixture, Main Distributing Boards, Bldg Earthing, Internal Electric Supply Services And Other E/M Works In Omq, Otm Accn And Technical Area
Open Tender
Indian
Tamil Nadu
sulur
14-06-2023

Tender Details

Repair/ Maint Of Internal Electrification Fittings, Fixture, Main Distributing Boards, Bldg Earthing, Internal Electric Supply Services And Other E/M Works In Omq, Otm Accn And Technical Area Repair/ Maint Of Internal Electrification Fittings, Fixture, Main Distributing Boards, Bldg Earthing, Internal Electric Supply Services And Other E/M Works In Omq, Otm Accn And Technical Area At Af Stn Sulur

Key Value

Document Fees
INR 500 /-
EMD
INR 99000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR / MAINT OF INTERNAL ELECTRIFICATION FITTINGS, FIXTURE, MAIN DISTRIBUTING BOARD"S, BLDG EARTHING, INTERNAL ELECTRIC SUPPLY SERVICES AND OTHER E/M WORKS IN OMQ , OTM ACCN AND TECHNICAL AREA AT AF STN SULUR
Sl. No. Item Description
1SCHEDULE A BOQ
2Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5m deep in hard/dense soil and getting out for taking down/laying of pipes complete all as specified and directed.
3Returning, refilling including spreadinglevelling watering and well ramming in layers not exceeding 25cms thick in hard/dense soil complete all as specified and directed.
4Removing excavated materials not exceeding 50m distance and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified and directed.
5Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as specified and directed. Note :- In case sufficient sand not obtained from excavation, the quoted rate is deemed to be inclusive for the required additional qty obtain from out side MD land as directed by the Engineer-in-Charge.
6M&L Fly ash bricks using modular bricks as in cable protection cover including taking down existing bricks of any size complete all as specified and directed.
7Supply and lay XLPEinsulated,screened ,PVC bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium conductor, multi strand, 1100Volts grade cross sectional area 6 Sqmm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed.
8Supply and lay XLPEinsulated,screened ,PVC bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium conductor, multi strand, 1100Volts grade cross sectional area 10 Sqmm 2 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed.
9Supply and lay XLPEinsulated,screened ,PVC bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium conductor, multi strand, 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed.
10Supply and lay XLPEinsulated,screened ,PVC bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium conductor, multi strand, 1100Volts grade cross sectional area 25 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed.
11Note for Item No 07 to 10:- Earth work excavation, RFR, Removal, Cushioning, cable cover protection/ pipe etc will be measured and paid seperately
12M & L repair/ maintenance and making the continuity of supply for rectifying the defects including taking down defective electrical items such as light point, fan/exhaust fan point, call bell point, socket point 5A/15A, switches, sockets, regulator, lamp holder, brackets, bell, buzzer, push button, ceiling rose, pendent, any type of MCB"s, SPN DB"s any type of internal light fixtures, any type of lamp, ceiling fan, exhuast fan, geyser, capacitor, replacement of fuse wires and all elcectrical accessories in day to day/door to door maintenance including reconnection with S&Fsmall pieces of elctrical cable of size upto 6 sqmm single core and length not exceeding 0.50m complete all as specified and as directed.
13Note:- following shall be part of job under item No 12:-
14(a)The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced before commencement of work.
15(b) All bldg light complaints including service connection, submain & internal electric for entire Domestic area of AF Stn sulur shall be attended.
16(c) Record of complaints/complaint slip showing qtr No, bldgs No, nature of job supported with users signature shall be prepared as per format directed by Engr-in-charge & will be deposited to concerned JE E/M within 24 hrs.
17(d) Necessary complaints slip/complaints register & other stationary required shall be contractor responsibility.
18(e)All sort of petty T&P items such as PVC insulation table, ladder, galvanised screws, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept.
19(f) Defective items if any, required to be replaced shall be measured and paidseparately.
20(g) The quoted rate is deemed to be inclusive for small pieces of elctrical cable of size upto 10 sqmm single core and length not exceeding 0.50m
21(h)The contractor shall maintain a record of all urgent/ routine works and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
22(j)In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
23(k)The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than twelve hrs after handing over works of urgent/ routine nature to the contractor. The Engr-in-Chargeshall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip.The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive.If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Chargeand the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
24(l) The decision of the Accepting Officer in this regard shall be final and binding.
25Supply & fix switch piano flush type 5 Amps240 volts single pole one way complete all as specified and directed. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
26Supply & fix switch piano flush type 5 Amps240 volts single pole two way complete all as specified and directed. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
27All as per item No 26 here-in-beforebut 15 Amp complete all as specified and directed. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
28Supply & fix shuttered socket outlet 3 pin 5 amps, flush type complete all as specified and directed.
29Supply & fix shuttered socket outlet 2 in 1, 5 pin, 5 and15 amps complete all as specified and directed.
30Supply & fix switch socket combination out let 3 pin 5 amps, flush type complete all as specified and directed. .
31Supply & fix switch socket combination out let 5 in 1, 5 pin 5 and 15 amps, flush type complete all as specified and directed. .
32Supply & fix for Ceiling rose 3 plates flush type 6 Amps,250 volts ACISI marked complete all as specified and directed.
33Supply & fix lamp holder, insulated body, cord grip pattern SP 230 volt, complete all as specified and as directed.
34Supply & fix electronicfan regulator 230 volts, step type socket type, hum free 100/240 watt complete all as specified and directed. Make :Havells / Schnieder/ crabtree
35Supply & fix PVC gang box 1 way 05 amp complete all as specified and directed. Make. Cona/SSK/Anchor
36Supply & fixElectronic ballastfor 36/40 Wflourecent tube light fittngs, 230V, complete all as specified and directed. Make : Sumo Slim EBE(Slim) 136 TLD 240 of Philips or equivalent of Bajaj/Crompton Greaves (CG)
37Supply and fix in repairPVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 1.5sqmm 3 core complete all as spcified and directed. Make : Havells/ Polycab/ Plaza
38Supply and fix in repairPVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 2.5sqmm 3 core complete all as spcified and directed. Make : Havells/ Polycab/ Plaza
39Supply and fix in repairPVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 4sqmm 3 core complete all as spcified and directed. Make : Havells/ Polycab/ Plaza
40Supply and fix in repairPVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 6sqmm 3 core complete all as spcified and directed. Make : Havells/ Polycab/ Plaza
41Supply & fixstarter for 40Wflourecent tube light fittngs 1x40 /2x40 watts 230V complete all as specified and directed. Make : Philips/ Bajaj/ CG
42Supply & fixsinglepole MCB 6 to 32 Amps, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996all as specified and directed. (Make/Model : Lexic MCB of MDS LegrandCat No :408587 to 408595 / Siemens/ Schnieder.
43Supply & fix electric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make : Anchor/ cona/ Plaza
44Supply and fix LED bulb(Green colour)15Watt B22 holder based complete all as spcified and directed. Make : Philips, Bajaj or CG
45Supply and fix energy saving lamps 2W/3W/5W SUODI LIGHTING day light spiral type complete all as spcified and directed. Make : Philips/ Crompton Greaves/ Bajaj
46S&F small thread LED candle bulb 05 watt, warm white E-14, 2700K as per sample complete all as specified and directed. Make : Philips/ Wipro/ Bajaj
47S&F big thread LED candle bulb 05 watt, warm white E-27, 2700Kas per sample complete all as specified and directed. Make : Philips/ Wipro/ Bajaj
48Supply & fix 7 watt LED lamp complete all as specified and directed. Make : Philips/ Bajaj/ Crompton Greaves
49Supply & fix 2.5 mfd condensor for ceiling fan complete all as specified and directed. Make : Epcos/ Asian/ Tyton
50Supply & fix plug top 3 pin 15 ampsAC 230 volts complete all as specified and directed. Make : Havells/ Cona/ Plaza
51Supply & fix plug top 3 pin 5 ampsAC 230 volts complete all as specified and directed. Make : Havells/ Cona/ Plaza
52Supply & fix bakelite sheet not less than 3 mm thick of size 100 x 100 mm complete all as specified and as directed. Make : Hylam/ Formica/ Green laminated boards
53Supply & fix TP, MCB 40 to 63 amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996complete all as specified and directed. (Make/Model : Siemens/ Schneider/ L&T.
54Supply & fix TPN, MCB 20 to 32 amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996complete all as specified and directed. (Make/Model : Siemens/ Schneider/ L&T.
55Supply & fix electronicfan regulator modular typre 230 volts, step type socket type, hum free 100/240 watt complete all as specified and directed. Make :Havells / Schnieder/ Crabtree.
56Supply & fix insulation tape 25 mm width 10m long complete all as specified and directed.
57Supply and fix electronic LED driver 36W suitable for 2" x 2" ceiling light indoor fitting complete all as specified and directed. make Philips/ Luker/ Wipro/ Bajaj as directed by Engineer-in-Charge.
58Supply & fix PVC rectangular/square block 75mmx75mmx35mm complete all as specified and directed.
59Supply & fixElectronic ballastfor2 x 36/40 Wflourecent tube light fittngs, 230V, complete all as specified and directed. Make : Sumo Slim EBE 236 TLD 240 of Philips or equivalent of Bajaj/CG
60Supply & fix 4" 20W/ 18W LED tube rod suitable for existing fitting complete all as specified and directed. Make : Philips, Bajaj, Havells
61Supply & fix bell push complete all as specified and directed. Make : Anchor/ Cona/ Havells
62Supply and fix bell push modular 1 way complete all as specified and directed. Make : Anchor/ Cona/ Havells
63Supply & fixElectronic ballastfor28W TL5 lampflourecent tube light fittngs, 240V, complete all as specified and directed. Make :Sumo Slim EBE 128 TL5 240 of Philips or equivalent of Bajaj/CG
64Supply & fixElectronic ballastfor1x18Wflourecent tube light fittngs, 230V, complete all as specified and directed. Make :Philips or equivalent of Bajaj/CG
65Supply & fix PVC gang box 2 way 15 amp complete all as specified and directed. Make. Cona/SSK/Anchor
66Supply & fix bakelite sheet not less than 3 mm thick of size 200 x 250mm complete all as specified and as directed. Make : Hylam/ Formica/ Green laminated boards
67Supply & fix bakelite sheet not less than 3 mm thick of size 250 x 300mm complete all as specified and as directed. Make : Hylam/ Formica/ Green laminated boards
68Supply & fix 4 mfd condensor for ceiling fan complete all as specified and directed. Make : Epcos/ Asian/ Tyton
69Supply & fix electric buzzer, AC 230 volt, single pole complete all as specified and directed. Make : Anchor/ cona/ Plaza
70Supply & fixmodular switch1 way 6 amp.1 module complete all as specified and directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
71Supply & fixmodular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
72Supply & fixmodular switch1 way 16 amp.1 module complete all as specified and directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
73Supply & fix modular Socket, 16A - 2/3 pin combined 2 module complete all as specified and directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
74Supply & fixmodular white cover plate with frame,3 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
75Supply & fix modular white cover plate with frame,4 module complete all as specified and directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
76Supply & fixmodular white cover plate with frame,6 module complete all as specified and directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
77Supply & fixmodular white cover plate with frame,8 module complete all as specified and directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
78Supply & fixmodular white cover plate with frame, 12 module complete all as specified and directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
79Supply & fixmodular switch1 way 32 amp 2 module complete all as specified and directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
80Supply & fix in repair rigid non-metallic, PVC conduit pipe, medium grade of 32 mm bore, including bends, saddles, accessories complete all as specified and directed. Make : prince/ supreme / diplast
81Supply & fix in repair rigid non-metallic,PVC conduit pipe, medium grade of 25 mm bore, including bends, saddles, accessories complete all as specified and directed. Make : prince/ supreme / diplast
82Supply & fix switch socket combination outlet 3 in 1/ 3 pin 3 and 5 amps flush type with box complete all as specified and directed.
83Supply & fix switch socket combination outlet 5 in 1/ 5 pin 5 and 15 amps flush type with box complete all as specified and directed.
84Supply & fix electronic fan regulator 230 volts, step type, switch type, hum free 100/ 240 watt complete all as specified and directed. Make : Anchor/ Cona/ Havells
85Supply & fix Double pole MCB 40 amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996complete all as specified and directed. Make/Model : Siemens/ ABB/ Legrand.
86Supply & fix in repair PVC batten of 15 mm (width) complete all as specified and directed complete all as specified and directed. Make : Polycab/Modi/ Presto Plast
87Supply & fix in repair PVC batten of 20 mm (width) complete all as specified and directed complete all as specified and directed. Make :Polycab/Modi/ Presto Plast
88Supply & fix in repairPVC batten of 25 mm (width) complete all as specified and directed complete all as specified and directed. Make :Polycab/Modi/ Presto Plast
89Supply & fixTPN, MCB 40 to 63 amp, 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996complete all as specified and directed. (Make/Model : Siemens/ ABB/ Legrand.
90Supply & fix 9 watt LED lamp complete all as specified and directed. Make : Philips/ Bajaj/ CG
91Supply & fix of4 pin18 wattCFL complete all as specified and directed. Make: Crompton Greaves/ Havells/ Osram
92Supply & fix of4 pin36 wattCFL complete all as specified and directed. Make: Crompton Greaves/ Havells/ Osram
93Supply & fix PVC gang box 2 way 05 amp complete all as specified and directed. Make. Cona/SSK/Anchor
94Supply & fix bakelite sheet not less than 3 mm thick of size 175 x 100mm complete all as specified and as directed. Make : Hylam/ Formica/ Green laminated boards
95Supply & fix bakelite sheet not less than 3 mm thick of size 200 x 200mm complete all as specified and as directed. Make : Hylam/ Formica/ Green laminated boards
96Taking down carefully hangers lights for repairs, replacement including taking down of defective spare parts such as ballast, lampholders, lamp, capacitor,ignitor etc of capacity 150/250/400 watts HPSV/HPMV/MH including cleaning internally and externally fixing back the fitting in same position after repair and test complete all as specified and directed.
97Note:- following shall be part of job under this item :-
98(a)The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced before commencement of work.
99(b) All bldg light complaints including service connection, submain & internal electric for OTM accn andentire Tech area of AF Stn sulur shall be attended.
100(c) Record of complaints/complaint slip showing qtr No, bldgs No, nature of job supported with users signature shall be prepared as per format directed by Engr-in-charge & will be deposited to concerned JE E/M within 24 hrs, failing which a sum of Rs. 50.00 per day will be recovered from the contractor.
101(d) Necessary complaints slip/complaints register & other stationary required shall be contractor responsibility.
102(e)All sort of petty T&P items such as PVC insulation table, ladder, galvanised screws, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept.
103(f) Defective items if any, required to be replaced shall be measured and paid as supply only separately, however labour component shall be part of this item.
104(g)Pointwiring, sub main wiring, DB"s, earthing & conduit etc specifically mentioned as M&L, S&F shall be measured and paid seperately.
105(h)The contractor shall maintain a record of all urgent/ routine works and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
106(j)In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
107(k)The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than twelve hrs after handing over works of urgent/ routine nature to the contractor. The Engr-in-Chargeshall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip.The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive.If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Chargeand the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
108(l) The decision of the Accepting Officer in this regard shall be final and binding.
109Supply and fix ignitor suitable for HPSV/ HPMV/ MH fitting of wattage 150/ 250/ 400 watts complete all as specified and directed. Make : Bajaj/ CG/ Philips.
110Supply and fix high wattage metal halide lamp in elliptical / tubular shape of400 watts complete all as specified and directed. Make : Philips / Bajaj/ Wipro
111Supply and fix 33 mfd capacitor suitable for HPMV/ HPSV/ MH light fitting complete all as specified and directed. .
112Supply and fixMercury / Metal Halide lamp ballast with copper winding polyster filling and voltage taping at 220/240V for 400 WHPMV fittings complete all as specified and directed. Make:- Cat Part No BHL 400 X 261 ofPhilips or Bajaj/ Crompton Greaves
113Supply and fix 20 mfd capacitor suitable for HPMV/ HPSV/ MH light fitting complete all as specified and directed. .
114Supply and fix Mercury / Metal Halide lamp ballast with copper winding polyster filling and voltage taping at 220/240V for 250 WHPMV fittings complete all as specified and directed. Make:- Cat Part No BHL 250 X 261 of Philips or equivalent in Bajaj/ Crompton Greaves
115Supply and fix high wattage metal halide lamp in elliptical / tubular shape of250 watts complete all as specified and directed. Make : Philips /Bajaj/ Wipro
116Supplyand fix electronic LED driver 70/75 W suitable for hangar down light/flood light and indoor fitting complete all as specified and directed. Make:- philips/Wipro/Bajaj/CG/Havells as directed.
117Supplyand fix electronic LED driver 150/160 W suitable for hangar down light/flood light and indoor fitting complete all as specified and directed. Make:- philips/Wipro/Bajaj/CG/Havells as directed.
118Supplyand fix electronic LED driver suitable for flame proof LED light fitiings 150/160 W sun shelter down light/flood light and indoor fitting complete all as specified and directed. Make:- philips/Wipro/Bajaj/CG/Havells as directed.
119S&F in replacement on distribution board MCCB four pole, 125 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 complete all as specified and directed. Make :- Siemens/ L&T/ ABB
120Supply and fix metal clad switch socket triple pole and earth enclosure with a three pin and earth plug and socket complete with one triple pole MCB 32A, 415 V complete all as specified and directed.
121Supply and fix metal clad switch socket triple pole and earth enclosure with a three pin and earth plug and socket complete with one triple pole MCB 63A, 415 V complete all as specified and directed.
122M&L for Sub main wiring with PVC insulated unsheathedFRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVCcasing capping and all accessories fixed to wall/floors along with one run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.
123Note for Item No 122:- (a)2 runs of 4 sqmm cable along with 1run of 4 sqmm cable for earth conductor and one run ofPVC casing capping shall be measured as one length.
124(b)Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
125M&L for Sub main wiring with PVC insulated unsheathedFRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVCcasing capping and all accessories fixed to wall/floors along with one run of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.
126Note for Item No 125:- (a)2 runs of 6 sqmm cable along with 1run of 6 sqmm cable for earth conductor and one run ofPVC casing capping shall be measured as one length.
127(b)Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
128M&L for Sub main wiring with PVC insulated unsheathedFRLS cable 1100 volts grade multi stranded copper conductor cable 4 runs of 10 sqmm drawn through in and incl suitable size PVCcasing capping and all accessories fixed to wall/floors along with two runs of 10 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.
129Note for Item No 128:- (a)4 runs of 10 sqmm cable along with 2runs of 10 sqmm cable for earth conductor and one run ofPVC casing capping shall be measured as one length.
130(b)Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
131M&L for Sub main wiring with PVC insulated unsheathedFRLS cable 1100 volts grade multi stranded copper conductor cable 4 runs of 10 sqmm drawn through in and incl suitable size PVCconduit and all accessories fixed to wall/floors along with two run of 10 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.
132Note for Item No 131:- (a)4 runs of 10 sqmm cable along with 2run of 10 sqmm cable for earth conductor and one run ofPVC conduit shall be measured as one length.
133(b)Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
134S& F repair convetional type post topfitting with LEDPost tops lamp fitting 1x45 W LEDmade die cast aluminium with innovative glare free indirect lighting ditribution & IP 65 protectioninlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground all as specified and directed.Make/cat part No. CG cat no. LPTO-40/CDL/Bajaj Cat Part No. BRIL 45 W LED NW /philips.
135S & F in repairs 18 watt recess mounted sleek squaredownlighterenviornment friendly, new generation, energy savingwith high powerLED as light sources & clear glass inlcuding accessories all as specified and directed by Engr-in-Charge. Make /Model : Philips cat part No.DN 295B LED16S-6500 PSU WH/Wipro/ Bajaj.
136S&F in replacementfactory madepowder coated distribution board VTPN, 8 way double doorincludingbus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623all as specified. Make/Model : Siemens/Schnieder/ Legrand
137S&F in replacementfactory madepowder coated distribution board VTPN, 4 way double doorincludingbus bar, Neutral bar, standard DIN rail, earth bar completeall as specified and conforming to IS: 8623all as specified. Make/Model : Siemens/Schnieder/ Legrand
138S&F in replacementfactory madepowder coated distribution board VTPN, 12 way double doorincludingbus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623all as specified. Make/Model : Siemens/Schnieder/ Legrand
139S&F in replacementfactory madepowder coated distribution board TPN, 4 way double doorincludingbus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623all as specified. Make/Model : Siemens/Schnieder/ Legrand
140S&F in repairs Electronic energy meter single Phase 5 to 30Amps range capacity complete all as specified. Make : BENTEC / L&T/ABB Note :- Old unserviceable meter shall be deposited to E/M store yard.
141M&L for wiring for circuit complete submain wiring with 2 X1.5 sqmm single core PVC insulated, unsheathed FRLS 100 Volt grade multi stranded copper conductor cable drawn through and incl suitable dia rigid PVC conduit and accessories complete fixed surface to wall/roof/ceiling etc and including one run of 1.5 sqmm single corewire PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductoretc including taking down existing sub main wiring of any size and all as specified.
142Note for Item No 141:- (a)2 runs of 1.5 sqmm cable along with 1run of 1.5 sqmm cable for earth conductor and one run ofPVC conduit shall be measured as one length.
143(b)Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
144M&L for Sub main wiring with PVC insulated unsheathedFRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with one run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed.
145Note for Item No 144:- (a)2 runs of 4 sqmm cable along with 1run of 4 sqmm cable for earth conductor and one run ofPVC conduit shall be measured as one length.
146(b)Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
147M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with one run of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed..
148Note for Item No 147:- (a)2 runs of 6 sqmm cable along with 1run of 6 sqmm cable for earth conductor and one run ofPVC conduit shall be measured as one length.
149(b)Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
150M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size steel conduit and all accessories fixed to wall/floors along with one run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed..
151Note for Item No 150:- (a)2 runs of 4 sqmm cable along with 1run of 4 sqmm cable for earth conductor and one run ofsteel conduit shall be measured as one length.
152(b)Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
153M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size steel conduit and all accessories fixed to wall/floors along with one run of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed..
154Note for Item No 153:- (a)2 runs of 6 sqmm cable along with 1run of 6 sqmm cable for earth conductor and one run ofsteel conduit shall be measured as one length.
155(b)Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
156S&Ffactory madepowder coated distribution board SP & N 8 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623complete all as specified and directed. Make/Model : Siemens/ Schnieder/ ABB
157S&F in replacementfactory madepowder coated distribution board TPN, 4 way single doorincludingbus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623complete all as specified and directed. Make/Model : Siemens/ Schnieder/ ABB
158S&F in replacement of convetional type bollard fitting with LED bollard light fittings suitable for 1x9 watt LEDbollard in rectangular shaped vicotria design with opal acrylic diffuser and IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground complete all as specified and directed. Make /cat part No. CG cat no.LBLSN-10-CDL /Bajaj Cat Part No. BGBOS 600 9W LED /philips.
159S&F in replacement on distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 complete all as specified and directed. Make : Siemens/ L&T/ ABB
160S&F in repairs integrated LED bulk head luminarie fittings in engineering plastic housing with clear prismatic /opal diffuser /pressure aluminium die cast housing in white powder coating minimum IP-65 protection, system wattage not more than 10 watt (lumen output not less than 800 lumen) power factor more than 0.9, with surge protection device minimum 2KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm complete all as specified and directed. . Make : Wipro Cat part NO.LW07-4-XXX-57-G1 or equivalent in Philips Wipro/ Bajaj.
161S&F in repairs Electronic energy meter 3 Phase 30 to 60Amps range capacity. Make : BENTEC / L&T/ABB. Note :- Old unserviceable meter shall be deposited to E/M store yard.
162M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable4 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 2 runs of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size complete all as specified and directed.
163Note for Item No 162:- (a)4 runs of 6 sqmm cable along with 2runs of 6 sqmm cable for earth conductor and one run ofPVC casing capping shall be measured as one length.
164(b)Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
165S&F factory madepowder coated distribution board SP & N 4 way double door,includingbus bar, Neutral bar, standard DIN rail, earth bar completeall as specified and conforming to IS: 8623complete all as specified and directed. Make/Model : Siemens/ Schnieder/ Legrand
166S&F in replacement factory madepowder coated distribution board SP & N 2 way single door,includingbus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DBall as specified and conforming to IS: 8623 complete all as specified and directed. Make/Model : Siemens or equivalent of Schnieder & Legrand
167S&F in replacement on distribution board MCCB four pole, 63 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 complete all as specified and directed. Make : Siemens/ L&T/ ABB
168Supply & fix 5 watt LED lamp complete all as specified and directed. Make : Philips/ Bajaj/ CG
169Supply and Fixing in repairs indoor decorative extruded aluminium anodised housing /CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED T8 batten type luminaire (LED batten shall be prewired box type) retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink /aluminium housing for excellent heat dissipation;2 feet (appx) size, high efficiency electronic driver, system wattage 10 watt (lumen output not less than 1000 lumen), power factor more than 0.9, with surge protection device minimum 3KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glarefree, no UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmmcomplete all as specified anddirected. Make : Philips Cat part No.LHEXACP7IN1W00 or equivalent inWipro/ Bajaj
170Taking down aluminum/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete (Taking down of fittings such as switches, sockets, bells, ceiling rose, holders , regulators, light fittings, MCB, lamps etc shall be measured and paid seperately) and making good the disturbed plaster surfaces of wall, floor, ceilingand painting 2 coat of white wash/distamber to meet the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified and directed.
171M&Lfor point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral including and drawn through concealedPVC Conduit, ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators,sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed for the following:-. Make of Conduit : Avon Plast/ Supreme/ Diplast Make of Wire : Plaza/ Havells/Polycab Note: (a) Switches, sockets outlets,blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b)Connection of wire with switch, socket shall be through copper thumble (lugs) only.
172One light point/fan/bell point controlled by one switch
173All as per item No. 171 here in before but for One 3 pin socket out 5 ampon the same board
174All as per item No. 171 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
175All as per Sl No 171 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
176M&Lfor point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral including and drawn through PVC casing Caping with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators,sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed for the following:-. Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Havells/ Polycab Note: (Switches, sockets outlets,blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely).
177One light point/fan/bell point controlled by one switch
178All as per item No. 176 here in before but for One 3 pin socket out 5 ampon the same board
179All as per item No. 176 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
180All as per Sl No 176 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
181M&Lfor point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral including and drawn through medium grade steel conduit with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators,sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed for the following:- Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Havells/ Polycab Note: (Switches, sockets outlets,blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely).
182One light point/fan/bell point controlled by one switch
183All as per item No. 181 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
184All as per Sl No 181 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
185Supply and Fixing in repairs indoor decorative extruded aluminium anodised housing /CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED T8 batten type luminaire (LED batten shall be prewired box type) retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink /aluminium housing for excellent heat dissipation;4 feet (appx) size, high efficiency electronic driver, system wattage 20 watt (lumen output not less than 2000 lumen), power factor more than 0.9, with surge protection device minimum 3KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glarefree, no UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmmcomplete all as specified anddirected. Make : Philips Cat part No.LHEXBLP7IN1W020 or equivalent inWipro/ Bajaj
186M&Lpoint wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC casing Caping with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators,sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed for the following:- Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Polycab/ Havells
187One light point/fan/bell point controlled by one switch
188All as per item No. 186 here in before but for One 3 pin socket out 5 ampon the same board
189All as per item No. 186 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
190All as per Sl No 186 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
191M&Lpoint wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC conduit fixed on surface ofwall, columns etc with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators,sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed for the following:- Make of Conduit : Supreme/diplast/Avon plast Make of Wire : Plaza/ Polycab/ Havells
192One light point/fan/bell point controlled by one switch
193All as per item No. 191 here in before but for One 3 pin socket out 5 ampon the same board
194All as per item No. 191 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
195All as per Sl No 191 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
196Supply and Fix in repair switch piano flush type 5 Amps240 volts single pole one way complete all as specified and directed. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
197Supply and Fix switchin repair piano flush type 15 Amps240 volts single pole one way complete all as specified and directed. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
198Supply and Fixin repair shuttered socket outlet 3 pin 5 amps, flush type complete all as specified and directed.
199Supply and Fixin repair shuttered socket outlet 2 in 1, 3 pin, 5 and15 amps complete all as specified and directed.
200Supply and Fixin repairmodular switch1 way 6 amp.1 module complete all as specified and directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
201Supply and Fixin repairmodular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
202Supply and Fixin repairmodular switch1 way 16 amp.1 module complete all as specified and directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
203Supply and Fixin repair modular Socket, 16A - 2/3 pin combined 2 module complete all as specified and directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
204S&F in repairs Surface & wall mounted LED fitting including 5 watt LED tube rodcomplete with all accessories internally, pre-wired, connecting up withtwin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make : Philips Cat part No.LHEXBLP7IN1W005 or equivalent inWipro/ Bajaj
205M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable4 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 2 runs of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.
206Note for Item No 205:- (a)4 runs of 4 sqmm cable along with 2runs of 4 sqmm cable for earth conductor and one run ofPVC casing capping shall be measured as one length.
207(b)Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
208Supply and fixing pathway light decorative retrofit LED fitting with 9 W LED bulb including necessary excavation, PCC foundation, 1.5 mtr long GI pipe light grade 50 mm bore with base plate, cable junction box with 2 pole connector 32 A capacity including cable entry and exist knockouts, 1.5 mtr length 3 core 1.5 sqmm PVC insulated copper round cable from connector to light fitting, disposal of soil to outside MD land including taking down existing one all as specified and directed by Engineer-in-Charge. Make / Model of Light fitting : Athena 2 Prismatic of Havells Cat Part No : LHDC12115099 or equivalent in Wipro or CG.
209S&F in repairs 36 W LED recessed 2x2 luminaire with classic design & glare free soft illumination. Housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens. CRI >80, Color temperature5700±300K, THD <10% and PF >0.95, IP20, IK02.Life class of 50,000hrs @ L70, Operating Temperature: -10 TO +45 DEG.C; Input Supply Voltage Range:150-277 V, Frequency :50-60 HZ. Driver Safety requirement stds: IS 15885-2-13, complete all as specified and directed. Make : Bajaj Cat Part No Skylux - BZRSQL 30W GZi WH / Philips cat No RC 355 BLED 33-6500 PSU OD WH or equivalent in Wipro.
210Supply and fixing in repairs building security luminaire ofwatt 10 watt LED 1000 lumens light High power LED, with unique peanut lens to ensure uniform distribution, higher spacing between poles and maintenance free system with excellent thermal management including prewired andall as specified and directed Make : Philips/ Wipro/ Bajaj.
211Supply and fixing in repairs building security luminaire ofwatt 20 watt LED 1000 lumens light High power LED, with unique peanut lens to ensure uniform distribution, higher spacing between poles and maintenance free system with excellent thermal management including prewired andall as specified and directed, Make : Philips/ Wipro/ Bajaj.
212Supply and fixing electronic driver 10W suitable for bldg security light complete all as specified and directed. Make:- Bajaj/ Philips all as directed by Engineer-in-Charge.
213Supply and fixing electronic driver 20W suitable for bldg security light complete all as specified and directed. Make:- Bajaj/ Philips all as directed by Engineer-in-Charge.
214Supply and fixing in repairs LED flood light, 100 watts , 230 Volt, AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection, with impact and corrossion resistant complete with driver and lamp complete all as specified and directed. Make : Luker cat pat No. LFL 100 or Equivalent of Havells/Wipro.
215Supply and fixing in repairsLED flood light, 160 watts , 230 Volt, AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection, with impact and corrossion resistant complete with driver and lamp all as specified and directed. Make : Luker cat pat No. LFL 160 or Equivalent of Havells/Wipro.
216Supply and fixing in repairs ALCOR LED flood light, 50 watts RGB colour changing light, 240 Volt, with high quality lenses & reflector, High grade aluminium pressure Die-Cast Housing with toughened glass cover, IP-66 class of protection, complete with control gear and all accessories including necessory PCC foundation for placing of flood lightcomplete all as specified and directed by Engr in charge. Make : Luker cat pat No. LFLR 50 or Havells/Wipro or Equivalent.
217S&F in repairs 9 watt surface mounted sleek square down lighter environment friendly, new generation energy saving with high poer LED as light sources and clear glass including accessories complete all as specified and directed.
218S&F in repairs Switch flame proof rotary type with termination box in LM6, 16A, double pole 250V complete all as specified and directed. Make:- M/s Sudhir, Baliga or equivalent
219S&F flame proof LED light fitting 2x16 Watt , CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed. Make :- Sudhir, Bajaj, Baliga
220S&F in repairs Switch flame proof switch socket plug combined in LM6, cable termination box in LM6, 16A, double pole 250V complete all as specified and directed. Make:- M/s Sudhir, Baliga or equivalent
221S&F in repairs flame proof exhaust fan 300mm sweep 230 volts, with all accessories fixed on wall/ceiling including writing MES No with synthetic enamel paint complete all as specified and directed. Make of sudhir, Baliga or equivalent Note:- Old unserviceable flame proof exhaust fans shall be deposited to MES store Yard.
222Supply & fixindustrial type metal clad plug top & socket single pole and a neutral link earth enclosure with MCB SP 20 Ampcomplete all as specified and directed.
223S&FMCB SPN32/40 Amp , 240 v, 50 Hz ACsuitable for ‘C’ curve, 10 KA breaking capacitycomplete conforming to IS 8828 of 1996 all as specified Make/Model :- Legrand Cat Part No 408617 or equivalent. ofSchniede, Siemens.
224M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directlyin Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x6mm (upto 7.5m length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
225Note for Item here in above :- (a)All Joints should be joined by Exothermic Welding or Brazing.
226(b)After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
227(c)Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab.
228(d)After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
229M&L in repairs Galvanised Earth strip of size 25 x 4 mm fixed on proper post insulator at the instrument end complete all as per specified and as directed.
230Demolition of Brickwork/stone boulder masonry, built in cement mortar complete all as specified and as directed.
231M&L Fly ash Brick work with Old size brick, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:4 complete all as specified and directed.
232Taking down cement plaster on brick or stone walls, or concrete or ceilings etc., including raking out joints, hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises, removal and depositing serviceable materials where directed.
233M & L Rendering 10 mm thick in cement mortar 1:4 onbrick or stone or concrete surfaces finished even and smooth without using extra cement completeall as specified and directed.
234M&L for applying two coat of oil bound distemper over one coat of putty including preparation of newly plastered surfaces complete all as specified and as directed.
235Note for Item No 230 to 234:- The above items are required for making good the disturbed surfaces of wall/ ceiling during execution of electrical repairs.