Military Engineer Services-MES has published Tender For Repairs Maint And Services Of Split, Window Type Ac Desert Coolers, Refrigerators, Deep Freezers And Allied Works At Domestic Area At Af Stn Jodhpur. Submission Date for this Tender is 20-06-2023. Air Cooler Tenders in jodhpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

37850542
Corrigendum : Tender For Repairs Maint And Services Of Split, Window Type Ac Desert Coolers, Refrigerators, Deep Freezers And Allied Works At Domestic Area At Af Stn Jodhpur
Open Tender
Indian
Rajasthan
jodhpur
20-06-2023

Tender Details

Repairs Maint And Services Of Split, Window Type Ac Desert Coolers, Refrigerators, Deep Freezers And Allied Works At Domestic Area At Af Stn Jodhpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work : Repairs/Maint and servicing of split, window type AC, desert coolers, water coolers, refrigerators, deep freezers and allied works at domestic area at AF Stn Jodhpur
Sl. No. Item Description
1M&L for disconnecting and taking out unserviceable sealed unit of Reciprocating compressor having capacity 1.5 Ton, single phase, 230 volt including necessary modification of the foundation as required to install the new compressor, vaccumising the system, testing for pressure, rectification of leakage if required, and installation of new compressor of same capacity & make including gas charging with R-22/R-407C, testing to desired temperature complete allas specified & as directed by the Engineer-in-Charge.
2M&L for disconnecting and taking out unserviceable sealed unit of Reciprocating compressor having capacity 2.0 Ton, single phase, 230 volt including necessary modification of the foundation as required to install the new compressor, vaccumising the system, testing for pressure, rectification of leakage if required, and installation of new compressor of same capacity & make including gas charging with R-22/R-407C, testing to desired temperature complete allas specified & as directed by the Engineer-in-Charge.
3M&L for disconnecting and taking out unserviceable sealed unit of Rotary compressor having capacity 1.5 Ton, single phase, 230 volt including necessary modification of the foundation as required to install the new compressor, vaccumising the system, testing for pressure, rectification of leakage if required, and installation of new compressor of same capacity & make including gas charging with R-22/R-407C, testing to desired temperature complete allas specified & as directed by the Engineer-in-Charge.
4M&L for disconnecting and taking out unserviceable sealed unit of Rotary compressor having capacity 2.0 Ton, single phase, 230 volt including necessary modification of the foundation as required to install the new compressor, vaccumising the system, testing for pressure, rectification of leakage if required, and installation of new compressor of same capacity & make including gas charging with R-22/R-407C, testing to desired temperature complete allas specified & as directed by the Engineer-in-Charge.
5M&L for disconnecting and taking out unserviceable sealed unit of Inverter compressorhaving capacity 1.5 Ton, single phase, 230 volt including necessary modification of the foundation as required to install the new compressor, vaccumising the system, testing for pressure, rectification of leakage if required, and installation of new compressor of same capacity & make including gas charging with R-410A, testing to desired temperature complete allas specified & as directed by the Engineer-in-Charge.
6M&L for disconnecting and taking out unserviceable sealed unit of Inverter compressorhaving capacity 2.0 Ton, single phase, 230 volt including necessary modification of the foundation as required to install the new compressor, vaccumising the system, testing for pressure, rectification of leakage if required, and installation of new compressor of same capacity & make including gas charging with R-410A, testing to desired temperature complete allas specified & as directed by the Engineer-in-Charge.
7M&L for WATER JET servicing of SPLIT TYPE AC"s of 1.5/2.0 Ton capacity (complete indoor and outdoor unitby using service bag cover & cooling coil rinse solution for cleaning of coils), taking out the indoor top coveroutdoor top cover from existing location, cleaning of cooling coil , condenser coil,and other components usingclean water greasing of fan, motor, blower etc., without damage any part and re-install at the same location including testing and commissioning complete all as specified & directed by the Engineer-in-Charge. (Note: The contractor shall at his own cost arrange water for servicing purpose.)
8M&L for WATER JET servicing of WINDOW TYPE AC"s of 1.5/2.0 Ton capacity (complete unit by using service bag cover & cooling coil rinse solution for cleaning of coils), taking out the indoor & outdoor cover from existing location, cleaning of cooling coil, condenser coil,and other components usingclean water, greasing of fan, motor, blower etc.,without damage any part and Re-fixing/mounting, at the same location including making opening of window AC air tight and dust proof including testing and commissioning complete all as specified & directed by the Engineer-in-Charge. (Note: The contractor shall at his own cost arrange water for servicing purpose.)
9M&L for WATER JET servicing of CASSET TYPE AC"s/DUCTABLE AC"s of 2.5/4/5.5 Ton capacity (complete indoor and outdoor unitby using service bag cover & cooling coil rinse solution for cleaning of coils), taking out the indoor top coveroutdoor top cover from existing location, cleaning of cooling coil , condenser coil,and other components usingclean water, greasing of fan, motor, blower etc.,without damage any part and reinstall at the same location including testing and commissioning complete all as specified & directed by the Engineer-in-Charge. (Note: The contractor shall at his own cost arrange water for servicing purpose.)
10S&F in replacement Running capacitor of capacity 2.5 MFD, 230 volts, 50 HZ suitable for indoor unit complete all as specified & directed by the Engineer-in-Charge.
11S&F inreplacement Running capacitor of capacity 4 MFD, 230 volts, 50 Hz suitable for indoor unit complete all as specified & directed by the Engineer-in-Charge.
12S&F in replacement Running capacitor of capacity 6 MFD, 230 volts, 50 Hz complete all as specified & directed by the Engineer-in-Charge.
13S&F in replacement Running capacitor of capacity 45MFD, 230 volts, 50 Hz complete all as specified & directed by the Engineer-in-Charge.
14S&F in replacement Running capacitor of capacity 50 MFD 230 volts, 50 Hz complete all as specified & directed by the Engineer-in-Charge.
15S&F in replacement Starting capacitor of capacity 80-100 MFD, 230 volts, 50 Hz complete all as specified & directed by the Engineer-in-Charge.
16Taking down existing condensing fan motor from the unit and rewinding of condensing fan motor of capacity 1.5/2.0 Ton (split type/window type) of any make with super enamelled copper winding wireincluding replacement of the motor bushes , shaft and testing on load for the entire satisfaction of Engineer-in-Charge. Note : Rewinding of Fan motor is included in unit rate quoted by contractor. Nothing extra shall be paid on this account.
17Taking down existing fan blower motor of cooling unitand rewinding offan blower motor of cooling unit of capacity1.5/2.0 ton(split type/window type)unit with supper enamelled copper windingwire of suitable gaugewire including replacement of the shaft ,bushes and testing on load for the entire satisfaction of Engineer-in-Charge. Note : Rewinding of Fan motor is included in unit rate quoted by contractor. Nothing extra shall be paid on this account.
18S&Finreplacement condensing fan motorof capacity 1.5/2.0 Ton for split type AC"s, single phase, AC230 volts, 50 Hz of original make as per existing complete all as specified & directed by the Engineer-in-Charge.
19S&F inreplacement condensing fan motorfor 1.5 /2.0 Ton capacity WINDOW type AC"s single phase, AC230 volts, 50 Hz of original make as per existing complete all as specified & directed by the Engineer-in-Charge.
20S&F in replacement condensing fanDC motor for 1.5 /2.0 Ton capacity split type AC"s (For outdoor unit) of original make as per existing complete all as specified & directed by the Engineer-in-Charge.
21S&F in replacement Blower suitable (for indoor unit) of split type AC"s cap 1.5/2.0 Ton of original make as per existing complete all as specified & directed by the Engineer-in-Charge.
22S&F in replacement fan blades (ISI Marked) of suitable size for outdoor unit of 1.5/2.0 Ton Split type AC"s complete all as specified & directed by the Engineer-in-Charge.
23S&F inreplacement fan blade/blower (ISI Marked)of suitable size for capacity 1.5/2.0 ton of Window type AC"s complete all as specified & directed by the Engineer-in-Charge.
24M&L for repairing of PCB control card suitable for 1.5/2.0 Tonne capacity, split type /window type AC, single phase and make the PCB control card fully functionalcomplete all as specified & directed by the Engineer-in-Charge.
25M&L for repairing of PCB control card suitable for 1.5/2.0 Ton capacity invertor split type AC/ window ac, single phase and make the PCB control card functional complete all as specified & directed by the Engineer-in-Charge.
26S&F in replacementPCB control card suitable for AC indoor unit 1.5/2.0Ton capacity split type AC, single phase of original make as per existing etc., complete all as specified & directed by the Engineer-in-Charge.
27S&F in replacement PCB control card suitable for DC indoor unit 1.5/2.0 Ton capacity invertor split type AC, single phase of original make as per existing complete all as specified & directed by the Engineer-in-Charge.
28S&F inreplacement of PCB control card suitable Outdoor unitfor invertor type splitAC"s capacity 1.5/2.0 Ton of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
29Supply only in replacementof Remote suitable for 1.5/2.0 ton capacity split ACof original make as per existingat site complete all as specified & directed by the Engineer-in-Charge.
30S&F in replacement capillary copper tube (ISI Marked) of split /window type AC capacity 1.5/2.0 ton complete all as specified & directed by the Engineer-in-Charge.
31S&F in replacement condenser coil for window type AC 1.5/2.0 Ton capacity including charging of gas R-22/R407C complete all as specified & directed by the Engineer-in-Charge.
32S&F in replacement copper cooling coil for window type AC 1.5/2.0 ton capacity of including charging of gas R-22/R407C complete all as specified & directed by the Engineer-in-Charge.
33S&F in replacement inner grill round (ISI Marked) of window AC of any capacity and any make as approved by Engineer-in-Charge.
34S&F in replacement water tray (ISI Marked) for Indoor unit of split AC of any capacity and make as approved by Engineer-in-Charge.
35S&F in replacement of relay of split type AC of any make and any capacity complete all as specified & directed by the Engineer-in-Charge.
36S&F in replacement thermostat suitable for any make of window type AC 1.5 ton capacity complete all as specified & directed by the Engineer-in-Charge.
37S&F in replacement single pole contactor suitable for split type AC capacity 1.5/2.0 Ton complete all as specified & directed by the Engineer-in-Charge.
38M&L for dismantling the window type AC"s/split type AC"s of 1.5/2.0 ton finding out the leakage of condenser or cooling coil with pressure test and reassembling the same after repair the leakage point by brazing/soldering including gas charging with R-22, testing to desired temperature to the entire satisfaction ofEngineer-in-Charge.
39M&L for dismantling the window type AC"s/split type AC"s of 1.5/2.0 ton finding out the leakage of condenser or cooling coil with pressure test and reassembling the same after repair the leakage point by brazing/soldering including gas charging with R-410a/R-407c, testing to desired temperature to the entire satisfaction ofEngineer-in-Charge.
40Supply, laying & commissioning in replacementPVC sheathed cable with multi stranded copper conductor of size 2.5 sqmm 3 corecomplete all as specified & directed by the Engineer-in-Charge.
41S&F in replacement of copper tube (ISI Marked) of size ?” dia for any capacity of split type AC complete all as specified & directed by the Engineer-in-Charge.
42S&F in replacement of copper tube (ISI Marked) of size ¼” dia for any capacity of split type AC complete all as specified & directed by the Engineer-in-Charge.
43M&L in replacement of fire resistance, elastomeric Nitrile rubber tubing (NBR) for Pipe insulation thickness 10mm of size ?"dia for split type AC"s, any capacity complete all as specified & directed by the Engineer-in-Charge.
44M&L in replacement of fire resistance, elastomeric Nitrile rubber tubing (NBR) for Pipe insulation thickness 10mm of size¼"dia of split type AC"s any capacity complete all as specified & directed by the Engineer-in-Charge.
45S&F in replacement of flexible drain pipe (PVC BRAIDED hose pipe) of size 15 mm dia, for split type AC any capacity and any make complete all as specified & directed by the Engineer-in-Charge.
46S&F in replacement air filter element suitable for split type AC 1.5/2.0 Ton capacity any make complete all as specified & directed by the Engineer-in-Charge.
47M&L for fabricationof canopy stand for outdoor split typeAC unitwith 40mm x 6mm thick angle iron with flat strip including welding, cutting & installed at site with PCC locking arrangement including dismantling the old unserviceable canopy stand complete all as specified & directed by the Engineer-in-Charge.
48S&F in replacement wall mounting bracket stand suitable for 1.5/2.0 tonne capacity outdoor unit of split AC complete all as specified & directed by the Engineer-in-Charge.
49S&F inreplacementfloor mounted bracket AC stand, certified special coated super 50cm x 8 cm shelf bracket suitable for 1.5/2.0 ton outdoor unit capacity complete all as specified & directed by the Engineer-in-Charge.
50M&L for scraping and removing of old paint of MS sheet canopy and frame of condensing unit of split type air conditioner and preparation of steel surface and applying two coats of synthetic enamel paint of smoke grey colour (Ist quality) over one coat of zinc chromate primer complete all as specified & directed by the Engineer-in-Charge. Note : Spray Painting shall be carried out with Spray Gun & Compressor.
51S&F in replacement electronic circuit board with relay suitable for 4/5 KVA voltage stabilizer as per existing make and testing complete all as specified & directed by the Engineer-in-Charge.
52S&F in replacement the main transformerof voltage stabilizer capacity 4/5 KVA, with super enamelled copper windingwire of suitable size,including dismantling and taking out the old unserviceable winding wire completeall as specified & directed by the Engineer-in-Charge.
53M&L forsub main wiring with two runs of PVC insulated unsheathed multi stranded copper conductor FRLS cable 6 Sqmm 1100 volt gradeand one run of 4 Sqmm single coreas earth lead drawn through inand includingnon-metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, concealedin wall (includingaccessories like bends, tees junction boxes, etc fixed in wall or ceiling etc.) including 2.5 sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade as earth wire including taking out / down the existing unserviceable sub main wiring with conduit complete all as specified and directed by the Engineer in Charge. Note :- Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
54M&L forsub main wiring with two runs of PVC insulated unsheathed multi stranded copper conductor FRLS cable 4 Sqmm 1100 volt gradeand one run of 2.5 Sqmm single coreas earth lead drawn through inand includingnon-metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, concealedin wall (includingaccessories like bends, tees junction boxes, etc fixed in wall or ceiling etc.) including 1.5 sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade as earth wire including taking out / down the existing unserviceable sub main wiring with conduit complete all as specified and directed by the Engineer in Charge. Note :- Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
55S&F inreplacement sheet metal enclosure SPN withtwo pin and earth plug socket with & including 25Amps MCB "C"curve, single pole, 240 Volt AC complete all as specified & directed by the Engineer-in-Charge.
56S&F in replacement MCB, SP, 25 Amp, ‘C’ curve type, 10 KA complete all as specified & directed by the Engineer-in-Charge.
57S&F in replacement MCB, SPN, 25 Amp ‘C’ curve type, 230 volts, 10 KA complete all as specified & directed by the Engineer-in-Charge.
58S&F in replacement MCB, SP, 20 Amp, ‘C’ curve type, 230 volts, 10 KA complete all as specified & directed by the Engineer-in-Charge.
59S&F in replacement3 pin plug top cap, 15 Amp, AC 240 Volts, 50 Hz complete all as specified & directed by the Engineer-in-Charge.
60Dismantlingof split AC/window AC any capacity with proper pump down from the site and deposit to MES work shop for major repair works complete all as specified & directed by the Engineer-in-Charge.
61Fixing & commissioning only of split/window type AC, capacity 1.5/2.0 Ton including testing after installation complete all as specified & directed by the Engineer-in-Charge. Note :- (i) Copper tubing if required, shall bemeasured & paidseparately. (ii)AC dismantled from item no.60 here-in-before shall be reused under this items. (iii) The quoted rate including gas charging & testing to desired temperature to the entire satisfaction of Engineer-in-Charge.
62S&F in replacement display card of indoor unitof Split AC,capacity 1.5Tonof existing make complete all as specified & directed by the Engineer-in-Charge.
63S&F in replacement display card of indoor unitof Split AC,capacity 2.0 Tonof existing make complete all as specified & directed by the Engineer-in-Charge.
64S&F in replacement complete Indoor unit with remote of Split AC capacity 1.5 Ton any make complete all as specified & directed by the Engineer-in-Charge.
65S&F in replacement complete indoor unit with remote of Split AC capacity 2 Ton any make complete all as specified & directed by the Engineer-in-Charge.
66S&F in replacement of L & Key valve (ISI Marked) of size 5/8" for condenser unit of split type AC 1.5/2.0 Ton, complete all as specified & directed by the Engineer-in-Charge. Note : Proper leak check shall be carried after replacement of valve and make the unit fully functional.
67S&F in replacement L & key valve (ISI Marked)of size 1/4" for condenser unit split type AC 1.5/2.0 Ton, complete all as specified & directed by the Engineer-in-Charge. Note : Proper leak check shall be carried after replacement of valve and make the unit fully functional.
68S&F inreplacement offlair nut size 5/8" and 1/2"dia forsplit type AC ofany capacitycomplete all as specified & directed by the Engineer-in-Charge.
69S&F inreplacement offlair nut size 3/8" and 1/4" dia for split type AC ofany capacity complete all as specified & directed by the Engineer-in-Charge.
70S&F inreplacement of dead nut size 1/4 "" dia for any capacity of split type AC complete all as specified & directed by the Engineer-in-Charge.
71M&L for filling of Refrigerant R-22 complete all as specified & directed by the Engineer-in-Charge.
72M&L for filling of Refrigerant R-410a complete all as specified & directed by the Engineer-in-Charge.
73M&L for MCB, DB, SPN 8 way IP-54 double door, concealed in wall, IP 54 protection with MCB SPN ‘C’ Curve type, 40 amps- 01 No and MCB, SP, ‘C’ Curve type, 6 to 32 amps - 06 Nos including necessary connection lugging with copper lugs pin/Ring type including dismantling &taking down the old unserviceable DB with accessories andalso making good disturbed surfaces of wallsto match with existing complete all as specified & directed by the Engineer-in-Charge.
74M&L for MCB, DB, SPN, 4 way, IP-54double door,concealed in wall, IP 54 protection with MCB, SPN, ‘C’ Curve type, 40 amps -01 No and MCB, SP, ‘C’ Curve type, 6 to 32 amps -02 Nos including necessary connection lugging with copper lugs pin/ring typeincluding dismantling &taking down the old unserviceable DB with accessories andalso making good disturbed surfaces to match with existing complete all as specified & directed by the Engineer-in-Charge.
75S&F in replacement AC motor suitable for Indoor unit blower ofsplit type AC 1.5/2.0Tonof existing make, complete all as specified & directed by the Engineer-in-Charge.
76S&F in replacement DC motor suitable for indoor unit blowerofsplit type AC 1.5/2.0 Tonof existing make, complete all as specified & directed by the Engineer-in-Charge.
77M&L for seal the existing bore holes of walls with expandable polyurethane foam complete all as specified & directed by the Engineer-in-Charge.
78M&L for taking out unserviceable sealed unit (compressor) of water cooler of capacity storage/cooling 150/150 litres, single phase, 230 volt and replacing the same with new sealed unit (Compressor), including necessary modification of the foundation as required to suit the compressor, vaccumization, pressure testing, leakage rectification, charging of gas R-22/R-134a, oil filling and testing complete to the entire satisfaction of the Engineer-in-Charge. Make of compressor - Tecumesh/ Kirloskar
79All as per item No. 78, here-in-before, but of water cooler of capacity storage/cooling 120/60 litres.
80All as per item No. 78, here-in-before, but of water cooler of capacity storage/cooling 80/40 litres.
81M&L for rewinding of condensing fan motor with super enamelled copper wire single phase, 230 volts, capacity 1/16 HP for water cooler of capacity storage/cooling 150/150 litres, Complete all as specified & as directed by Engineer-in-Charge. Make of winding wire- Devi dayal/Chetak/ Usha thermal class E or any make specified inAppx "B"
82All as per serial item No. 81.00 here-in-before, but capacity 1/32 HP for water cooler of capacity storage/cooling 120/60 litres.
83All as per serial item No. 81.00 here-in-before, but capacity 1/35 HP for water cooler of capacity storage/cooling 80/40 litres.
84M&L for repair to bottom rusted and deteriorated portion of body of 150 litres capacity of water cooler replacement with 20 gauge mild steel sheet with necessary cutting, denting, welding including spray painting of complete hole bodywith one coat of approved synthetic enamel paint (Ist quality) over a coat of red oxide primer to the entire outer surface of the body and after repair of the leakage point by brazing/soldering including charging thegas R-22/R-134 and testing the water cooler to the entire satisfaction of the Engineer-in- Charge.
85All as per serial item No. 84.00 here-in-before, but 120/60 litres storage/cooling capacity of water cooler.
86All as per serial item No. 84.00 here-in-before, but 80/40 litres storage/cooling capacity of water cooler.
87M&L for finding out the leakage with the pressure test of the condenser or cooling coil of water cooler 150/150 litres storage/cooling capacity and dismantling the same for repair, reassembling the same after repair of the leakage point by brazing/soldering including charging the gas R-22/R-134 and testing the water cooler to the entire satisfaction of the Engineer-in- Charge.
88All as per serial item No. 87.00 here-in-before, but for water cooler of capacity storage/cooling 120/60 litres.
89All as per serial item No. 87.00 here-in-before, but for water cooler of storage/cooling capacity of 80/40 litres.
90S&F in replacement wiring kit for water cooler of any make and capacity.Make of wiring kit - Hi-Tech/Aanutrol/Tecumseh/Sriram
91S&F in replacement running capacitor for water cooler of6 MFD capacity, Make - Havells/Sarda/Epcos/ Jaivic
92S&F in replacement starting capacitor for water cooler of 80-100 MFD capacity,Make -Tesla/Havells/ Epcos/Jaivic
93S&F in replacement 15 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe (Minimum weight 142 gms) for water cooler, complete all as specified & as directed.
94S&F in replacement cast copper alloy, chromium plated lift cock of 15mm bore, complete all as specified & as directed.
95S&F in replacement cast copper alloy, chromium plated push cock of 15mm bore, complete all as specified & as directed.
96S&F in replacement of flexible PVC waste water pipe of water cooler any capacity and make as per existing all as specified & directed by Engineer-in-charge.
97S&F in replacement condensing fan motor 1/32 HP of water cooler.
98All as per serial item No. 84.00 here-in-before, but fan motor 1/16 HP.
99S&F in replacement of thermostat of water cooler any capacity and make as per existing all as directed by Engineer-in-charge.
100S&F in replacement of relay OLP set for water cooler capacity 40/80 ltr as per existing make all as directed by Engineer-in-charge.
101S&F in replacement of capacitor 36 MFD for water cooler as per existing make all as directed by Engineer-in-charge.
102S&F in replacement of capacitor 25 MFD for water cooler as per existing make all as directed by Engineer-in-charge.
103S&F in replacement of capacitor 15 MFD for water cooler as per existing make all as directed by Engineer-in-charge.
104S&F in replacement of condenser (heat exchanger) for water cooler capacity 150 ltr as per existing make all as directed by Engineer-in-charge.
105S&F in replacement of condenser (heat exchanger) for water cooler capacity 120/60 ltr as per existing make all as directed by Engineer-in-charge.
106S&F in replacement of condenser (heat exchanger) for water cooler capacity80/40 ltr as per existing make all as directed by Engineer-in-charge.
107M&L for servicing of water cooler of any capacity at existing location by cleaning of condenser, cooling coil, and other components with cooling coil rinse solution & clean water, greasing of fan, motor including cleaning of storage tank with treated water after applying the potassium permanganate solution etc., without damaging any part etc., complete all as specified & directed by the Engineer-in-Charge.
108M&L for over load relay 1/3 HP and capacitor 40 to 60 mfd.
109M & L for condenser motor fan blade suitable for water cooler capacity150/120/80/40 ltrs all as specified & directed by Engineer-in-Charge.
110S&F in replacementold hermetic sealed compressor of capacity 165/170/180 litre Refrigerator oftechmush/LG Make with the compressor of original manufacturer/authorized dealer including charging of refrigerant gas R134a and testing on full load all as specified and directed by the Engineer-in-Charge.
111All as per serial item No. 110.00 here-in-before, but of capacity of refrigerator 280/285/220 Litre.
112All as per serial item No. 110.00 here-in-before, but of capacity of refrigerator 320/340/310Litre.
113M&L for repair to bottom rusted and deteriorated portion of body of 285/320/310/340 litres capacity refrigerator up to 150 mm height by replacing with 20 gauge MS sheet, including cutting, denting, welding and spray painting to the entire body with two coats of approved synthetic enamel paint (Ist quality) over one coat of red oxide primer after rubbing/removing the existing old paint all as specified& writing SM No/MES No,40 to 50 mm high letter with white paint and also including charging of gas all as directed by the Engineer-in-Charge.
114All as per serial item No. 113.00 here-in-before, but refrigerator capacity 165/170/180 litres.
115S&F in replacement thermostat auto frosted type of refrigerator any capacity all as specified and directed by the Engineer-in-Charge.
116S&F in replacement freezer of 285/300/320 litres capacity Refrigerator all as specified and directed by the Engineer-in-Charge.
117All as per serial item No. 116.00 here-in-before but of 165/170 litres capacity Refrigerator all as specified and directed by the Engineer-in-Charge.
118S&F in replacement of condenser (heat exchanger) for Refrigerator capacity 165/170/180 ltr as per existing make all as specified & directed by Engineer-in-charge.
119S&F in replacement of condenser (heat exchanger) for Refrigerator capacity 285/310/340/320 ltr as per existing make all as specified & directed by Engineer-in-charge.
120S&F in replacement of relay OLP set suitable for 165 to 350 ltr capacity of Refrigerator as per existing make all as specified & directed by Engineer-in-charge.
121S&F in replacement of capillary suitable for refrigerator size 031/036 all as specified & directed by Engineer-in-charge.
122S&F in replacement of filter suitable for refrigerator size 180/285/310/340ltr all as specified & directed by Engineer-in-charge.
123M&L for repairing of PCB control card suitable for refrigerators of any capacity/size all as specified & directed by Engineer-in-charge.
124M&L for finding out the leakage with the pressure test of the condenser or cooling coil of Refrigerator 165 to 220 ltr capacity and dismantling the same for repair, reassembling the same after repair of the leakage point by brazing/soldering including charging thegas R-22/R-134a and testing the Refrigerator to the entire satisfaction of the Engineer-in- Charge.
125M&L for finding out the leakage with the pressure test of the condenser or cooling coil of Refrigerator 280 to 350 ltr capacity and dismantling the same for repair, reassembling the same after repair of the leakage point by brazing/soldering including charging thegas R-22/R-134a and testing the Refrigerator to the entire satisfaction of the Engineer-in- Charge.
126M&L for rewinding of desert cooler fan motor, any make, of capacity 4000 cum/hrs/5000cum/hrs with super enamelled copper wire of appropriate size as directed. Make winding wire– Devi dayal/Chetak/Usha
127S&F in replacement of capacitor capacity 4 MFD, 240 volts suitable for desert cooler fan motor. Make : Unistar/Kell/Assain/ Siemens/Epcos
128S&F in replacement 15 mm bore superior quality PVC pipe for vertical pump and distributor assembly.
129S&F in replacement weld mesh 3”x2” rectangle block of 12 SWG galvanized iron of size 24”x28” in size for side panels of desert coolers all as specified and directed by the Engineer-in-Charge.
130S&F in repairs front grill made of sheet steel as per sample complete with operating panel board for 4000 cum/hrs/5000cum/hrs capacity of desert cooler including two coats of grey synthetic enamel paint over a coat of red oxide primer.
131S&F in replacement 15mm bore elbow of PVC for desert cooler.
132S&F in replacement 15mm external dia PVC distributor assembly with 3 outlets for desert cooler.
133M&L for patch repair work to unserviceable / corroded portion of bottom tankand body of Desert cooler with 20 gauge PGI sheet including necessary welding and painting the new surfaces to match with existing surface and leakage testing complete all as per directed by Engineer-in-Charge.
134S&F inreplacement bottom water tank of size 750x750x200mm fabricated out of 18 gauge PGI sheet including nuts, bolts and washers etc., complete including painting with one coat of bituminous black paint inside and two coat of grey synthetic enamel paint on outside of tank over a coat of red oxide primer complete all as specified & as directed.
135S&F in replacement side panel made out of 22 gauge PGI sheet with suitable handles including painting to match with the existing desert cooler 4000 CFM all/5000CFM capacity complete all as specified & directed by Engineer-in-Charge.
136S&F in replacement of desert cooler body of size approx 660 x 660 x 900 mm with and including front grill and three side louver fabricated out of 22 gauge mild steel plain GIsheet and bottom water tank (sump) of size 660x660x200mm deep fabricated out of 20 gauge mild steel plain GI sheet including taking out and reinstallation complete with standard fittings such as PVC pipe for water, electric controls and switch, fan speed regulator, rewiring of fan motor and water lifting pumpincluding fixing and connecting existing cooler fan, electric pump with new 3 core PVC insulated & PVC sheathed cables (min. 3 metre in length).External surfaces shall be spray painted with two coats of approved synthetic enamel paint over a coat of red oxide primer and internal surface of body, cooler pump and motor shall be painted with two coats of bituminous paint over a coat of red oxide primer complete all as per sample kept in AGE E/M office and all as specified and directed by the Engineer-in-Charge.
137M&L for scraping and removing of old paint of desert cooler body (steel surface) and preparation of steel surfaces including necessary denting/welding/cutting etc., and spray painting two coats with smoke grey synthetic enamel paint (Ist quality) over a coat of red oxide primer on outer surface and inner surface i.e. water tank and body, fan mounting blades shall be painted with a coat of anticorrosive black paint over a coat of red oxide primer complete for desert cooler of any size and capacity including writing MES No with white synthetic enamel paint 40 to 50 mm high letters all as specified and directed by the EIC.
138S&F in replacementwood wool pad 30mm thick duly winded with the nylon mesh of standard size for 4000 cum/hr / capacity desert coolers.
139All as per serial item No. 138.00 here-in-before, but suitable for 5000 cum/hr capacity desert coolers.
140M&L for rewinding of Desert cooler exhaust fan motor capacity 1HP with super enamelled copper wire of appropriate size as directed & including replacement of capacitor 25 Mfd 440 volts.
141S&F in replacement submersible pump of discharge head 1.5 metre 220-240 volts AC supply single phase 40 watt
142S&F in replacement desert Cooler exhaust fan metal blade 18" to 24”.
143S&F in replacement selector switch with Knob three speed fan motor.
144S&F in replacement aluminium fan blade with bracings, screw, of size 18"/20” desert cooler heavy duty as per sample.
145S&F in replacement desert cooler fan motor capacity 1 HP three speed 1400 RPM single phase with fan blade stand and selector switch Make – GEC/Khaitan
146M&L for painting of desert cooler stand with two coats of synthetic enamel paint of approved colour over a coat of red oxide including preparation old surfaces complete all as specified and directed by Engineer-in-Charge.
147S&F in replacement 3 pin plug top cap 5 Amp AC 240 Volts 50 Hz.
148S&F in replacement 3 pin plug top cap 15 Amp AC 240 Volts 50 Hz.
149S&F in replacement of main lead 3 core,8 feet length with 3 pin plug top cap 5 Amp AC 240 Volts 50 Hz
150S&F in replacement of leg set with grommet for desert cooler any capacity as per existing make all as directed by Engineer-in-charge.
151Supply and fix switch 6 A, 1 way, piano type, as per existing make all as directed by Engineer-in-charge.
152S&F in replacement motor fixing ring for desert cooler eight screw/clip type (as per sample).
153S&F in replacement of copper wound wire electric motor 4000 cum/hrs/5000cum/hrs capacity for desert cooler. Make : CG /KHAITAN
154S&F in replacement fan motor 3phase, 1.1 KW 380 V suitable for industrial cooler.
155S&F in repair /rewinding fan motor 3 phase, 1.1 KW, 380 V, suitable for industrial cooler.
156S&F in replacement water lifting pump vertical type suitable for industrial cooler.
157S&F in replacement wiring kit suitable for industrial cooler.
158S&F in replacement fan blade of size 600mm with complete assembly suitable for industrial cooler including installation, commissioning, testing etc., complete to entire satisfaction of Engineer-in-Charge.
159S&F in replacement of TPN, capacity 3 Amp, for industrial cooler as per existing make all as directed by Engineer-in-charge.
160S&F in replacement of honey pad suitable for kavva industrial cooler as directed by Engineer-in-Charge.
161M&L for taking out unserviceable sealed unit (compressor) of Deep freezer of capacity storage/cooling 300-350 litres, single phase, 230 volt and replacing the same with new sealed unit (Compressor), including necessary modification of the foundation as required to suit the compressor, vaccumization, pressure testing, leakage rectification, charging of gas R-22/R-134a, oil filling and testing complete to the entire satisfaction of the Engineer-in-Charge. Make of Compressor - Tecumesh/ Kirloskar
162S&F in replacement of condenser fan motor for Deep freezer including installation, commissioning, testing etc., complete to entire satisfaction of Engineer-in-Charge.
163M&L for finding out the leakage with the pressure test of the condenser or cooling coil of Deep freezer 300 to 350 ltr capacity and dismantling the same for repair, reassembling the same after repair of the leakage point by brazing/soldering including charging the gas R-22/R-134a and testing the Deep freezer to the entire satisfaction of the Engineer-in- Charge.
164S&F in replacement of condenser (heat exchanger) for Deep freezer capacity 300 to 350 ltr and make as per existing all as directed by Engineer-in-charge.
165M&L for disconnecting, cutting and taking out unserviceable sealed unit (compressor) 5.5 Tonne capacity cassette AC, Three phase, 415 volt including necessary modification of the foundation asrequired to suit the new compressor, vacumisation, pressure, testing, leakage, rectificationand supply & fixing of new compressor of same capacity and make including gas charging R-22/R-407c and testing complete all as specified & directed by the Engineer-in-Charge.
166S&F in replacement ofoutdoor unit capacity 1.5 ton with fan motor ,fan blade and suction and discharge L key valve and capillary for splittype 1.5 TR AC ofexisting make and model complete all as specified and directed by Engr-in-charge.
167S&F in replacement ofoutdoor unit capacity 2 ton with fan motor ,fan blade and suction and discharge L key valve and capillary for split type 2 TR AC ofexisting make and model complete all as specified and directed by Engr-in-charge.