Tender For Repair/Maint Of Summer Appliances, Ceiling Fan, Ext Fan And Other Allied Works At Nams, Amritsar-Punjab

Military Engineer Services-MES has published Tender For Repair/Maint Of Summer Appliances, Ceiling Fan, Ext Fan And Other Allied Works At Nams. Submission Date for this Tender is 21-06-2023. Air Conditioner Tenders in Amritsar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

37829578
Corrigendum : Tender For Repair/Maint Of Summer Appliances, Ceiling Fan, Ext Fan And Other Allied Works At Nams
Open Tender
Indian
Punjab
Amritsar
21-06-2023

Tender Details

Repair/Maint Of Summer Appliances, Ceiling Fan, Ext Fan And Other Allied Works At Nams

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Jun-2023 Revised BOQ BOQ 14-06-2023
2 14-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 72000.0 /-
Tender Value
INR 36 Lakhs /-

BOQ Items

Name of Work : REPAIR/MAINT OF SUMMER APPLIANCES, CEILING FAN, EXT FAN AND OTHER ALLIED WORKS AT NAMS
Sl. No. Item Description
1Water Cooler:- Servicing/ Inspection of water cooler of any capacity/type/make installed at different units at NAMS on site including disconnecting electric and water connection of water cooler finding of defect including dismantling of compressor, relay, capacitor, thermostat, motor, PVC hose pipe, condensing coil including fixing new spares/ parts complete as required all as specified and directed by Engineer -in-charge. Note (i) The new spare /parts required to make the water cooler serviceable shall be measured and paid separately as supply & fixing under relevant items . (ii) Transportation charges for carrying the plant from site to workshop and back at site incl testing & fixing are deemed to be included in quoted rates. (iii) Replacement of minor spare/parts whose cost are less than 100 rupees including cleaning of water tank, servicing etc are deemed to be included in quoted rates. no extra cost shall be paid for the same. (iv) Detecting the Gas leakage,Vacuuming the unit andrectify it by gas welding/brazing , charging of refrigerant gas .(v) Refrigerant gas shall be measured and paid seperately under relevent item.
2Supply and fixingof new compressor sealed unit suitable for water cooler of any make/type and 150 ltr/120 ltr/ hr cooling capacity, medium temperature range, including replacement of filter and making connectionand detect of leakage and rectifying it by gas welding or any other means etc. including Gas charging ofany type refrigerantas required on siteincluding testing of new sealed unit compressor complete all as specified and directed by Engineer-in charge. Make : Kirloskar / Carrier / Tecumseh /Copeland
3Description all as per srl item No 2.00 here-in-before but water cooler of any make/type and40/80 ltr/ hr cooling capacity.
4Supply and fixing of starting relay/Over load protector Complete all as specified and as directed by Engr-in-Charge.
5Supply only refrigerant gas of " R-22" suitable for compressor of water cooler/ Refrigerator/deep freezer and AC of any make ,capacity and typecomplete all as specified and directed by Engineer-in charge.
6Supply and fixing in replacement of evaporator coil/Condenser coilsuitable for water cooler of any make/type/capacity including making connection complete all as specified and directed by Engineer-in charge.
7Supply and fixingof Starting/running capacitor ISI marked in existing water cooler of any make/type/capacity including all fixing accessories etc complete all as specified and directed by Engineer-in-charge. Make – USHA/UNISTAR/TIBCON
8Supply and fixingof thermostat suitable for any cap. water cooler Complete all as specified and as directed by Engr-in-Charge.
9Supply and fixingof fan motor with blades of capacity 1/10 to 1/35 HP 50c/s, 230 voltsComplete all as specified and as directed by Engr-in-Charge.
10Supply and fixingof PVC hose waste pipe with SS clamp suitable for water cooler of any capacity Complete all as specified and as directed by Engr-in-Charge.
11Supply and fixingof drain tray , stainless steel for water cooler of any cap complete all as specified and as directed.
12Material and Labourfor replacement of old damage rusted water cooler body with new water cooler body fabricated from MS Sheet 18 Guage thick, necessary angle iron work of required size, cleaning, washing the sheetwith moderate solution, duly painted with two coats of synthetic enamel paint over one coat of red oxide primer including writing MES/SM number with white paint of appropriate size complete all as directed byEngineer InCharge.
13Refrigerator:- Servicing /Inspection of refrigerators of any cap/type/make installed at different units atNAMS on site, finding of defect including dismentling of compressor, relay, capacitor, thermostat, motor, condensing coil , door, rubber gasket, ice box assembly including fixing new spares complete as required all as specified and directed by Engineer -in-charge. Note (i) The new spare parts required to make the water cooler serviceable shall be measured and paid separately as supply & fixing under relevant items . (ii) Transportation charges for carrying the plant from site to workshop and back at site incl testing & fixing are deemed to be included in quoted rates. (iii) Replacement of minor spare parts whose cost are less than 100 rupees including cleaning of unit, serciving etc are deemed to be included in quoted rates. no extra cost shall be paid for the same. (iv) Detecting the Gas leakage,Vacuuming the unit andrectify it by gas welding/brazing and charging of refrigerant gas . (v) Refrigerant gas shall be measured and paid seperately under relevent item.
14Supply and fixing ofcompressor sealed unit alongwith one year guarantee certificate suitable for refrigerator of capacity 165 to 210 ltr ofany make/type, medium temperature range, including replacement of foundation bolts, rubber pad, strainer, capillary tubes, suction and discharge pipe line and includinggas charging ofany typerefrigerant as required on site and detect of leakage etc complete all as specified and directed by Engineer-in charge. Make : Kirloskar / Carrier / Tecumseh /Copeland/Godrej/Whirlpool, LG
15Description all as peritem No 14.00 butof capacity 215-360 ltr Complete all as specified and as directed by Engr-in-Charge.
16Supply only refrigerant gas of " R-134a" suitable for compressor of water cooler/ Refrigerator/deep freezer and AC of any make ,capacity and typecomplete all as specified and directed by Engineer-in charge.
17Supply and fixing of relay and over load protectionfor refrigerator of any capacity any type Complete all as specified and as directed by Engr-in-Charge./starting relay
18Supply and fixing of evaporator coil/Condenser coilsuitable for refrigerator/deep freezer of any make/type/capacity including making connection complete all as specified and directed by Engineer-in charge.
19Supply and fixingof thermostat for refrigerator of any capacity/any type Complete all as specified and as directed by Engr-in-Charge.
20Supply and fixing of glass/PVC shelf/cover for vegetable tray/ bulbsuitable for refrigerator/deep freezer of any make/type/capacity including making connection complete all as specified and directed by Engineer-in charge.
21Supply and fixing in replacement of PC Board forrefrigeratorof any make/capall as specified and as directed by Engr-in-Charge.
22Supply and fixingof freezer forrefrigeratorof any make/capall as specified and as directed by Engr-in-Charge.
23Supply and fixing of timer/heater for refrigerator complete all as specfied and as directed.
24Deep Freezer:- Servicing /.Inspection of Deep Freezer of any cap/type/make installed at different units atNAMS on site, finding of defect including dismentling of compressor, relay, capacitor, thermostat, motor, condensing coil , door, rubber gasket, ice box assembly including fixing new spares/parts complete as required all as specified and directed by Engineer -in-charge. Note (a) The new spare/parts required to make the water cooler serviceable shall be measured and paid separately as supply & fixing under relevant items . (b) Transportation charges for carrying the plant from site to workshop and back at site incl testing & fixing are deemed to be included in quoted rates. (c) Replacement of minor spare parts whose cost are less than 100 rupees including cleaning of water tank, serciving etc are deemed to be included in quoted rates. no extra cost shall be paid for the same (iv) Detecting the Gas leakage,Vacuuming the unit andrectify it by gas welding/brazing , charging of refrigerant gas . (v) Refrigerant gas shall be measured and paid seperately under relevent item.
25Supply and fixingof new compressor alongwith one yearguarantee certificate suitable for deep freezer of capacity 300-400 ltrs and any make/type, medium temperature range, including replacement of foundation bolts, rubber pad, strainer, capillary tubes, suction and discharge pipe line and subsequentlyGas charging ofgas type as required on site and detect of leakage etc complete all as specified and directed by Engineer-in charge.
26Description all as per item No 25.00 here in but for deep freezer of 100-205 ltr capacity Complete all as specified and as directed by Engr-in-Charge.
27Supply and fixing offan motor for deep freezer of cap upto 400Ltrs cap Complete all as specified and as directed by Engr-in-Charge.
28Split/Window AC:- Servicing/ Inspection of AC window/splittype of any cap/type/make installed at different units atNAMS on site, including jet washing,cleaning of filter,coils & checkingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit, fan, blower, etc., finding of defect including dismentling of compressor, blower motor, evaporating coil, relay,thermostat,condensing coil and keepingthe AC unit in satisfactory working condition after necessary servicing/ repair including fixing new spares complete as required all as specified and directed by Engineer -in-charge. Note (i) The new spare parts required to make the water cooler serviceable shall be measured and paid separately as supply & fixing under relevant items. (ii) Transportation charges for carrying the plant from site to workshop and back at site incl testing & fixing are deemed to be included in quoted rates. (iii) Replacement of minor spare parts whose cost are less than 100 rupees includingserciving etc are deemed to be included in quoted rates. no extra cost shall be paid for the same. (iv) Detecting the Gas leakage,Vacuuming the unit andrectify it by gas welding/brazing , charging of refrigerant gas . (v) Refrigerant gas shall be measured and paid seperately under relevent item.
29Supply and fixing of new compressor of capacity 2.0 Ton for window/split type, medium temperature suitable for air conditioner of any make/type including replacement of foundation bolts, rubber pad, strainer capillary tubes, suction and discharge pipe line, wiring kit, Gas charging (R-22/R-32/R-410A) and detect of leakage etc. and testing of new sealed unit compressoralongwith one yearguarantee certificate complete all as specified and directed by Engineer-in-charge. Make :Carrier / Tecumseh /Emerson/Hitachi/Godrej..
30Description all as per item No 29.00 here in but for window/split AC of 1.5 Ton capacity, specifications as per existing Complete all as specified and as directed by Engr-in-Charge.
31Supply and fixing of condensing coil of copper for window/Split air conditioner of cap 1.5/2 ton capacity as required on site complete all as specified and as directed by Engr-in-Charge.
32Supply and fixing of refrigerant gas of " R-32/ R 410A" suitable for compressor of water cooler/ Refrigerator/deep freezer and AC of any make ,capacity and typecomplete all as specified and directed by Engineer-in charge.
33Supply and fixing of evaporatingcoil of copper for window/Split air conditioner of cap 1.5/2 ton capacity as required on site complete all as specified and as directed by Engr-in-Charge.
34Supply and fixingof Starting/Running capacitor suitable for air conditioner of any make / type / capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
35Supply and fixing of thermostat for window/Split AC of cap1.5/2 ton as per existng make complete all as specifeid and directed.
36Supply and fixing ofmicron filter suitable for 1.5/2 Ton window/Split AC Complete all as specified and as directed by Engr-in-Charge.
37Supply and fixing ofblower motor for window air conditioner of capacity 1.5 /2 ton, type & specification as per existing Complete all as specified and as directed by Engr-in-Charge.
38M&L for Window AC front grill complete as per existing for 1.5/2.0 Ton Complete all as specified and as directed by Engr-in-Charge.
39Supply and fixing ofblower/fan motor for outdoor unit of split air conditioner of capacity 1.5/2ton, specification as per existing complete all as directed by engineer-in-charge
40Supply and fixingof electronic control circuit card suitable for air conditioner of any make / type and 1.5 / 2.0 ton capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
41Repairof electronic control circuit card suitable for air conditioner of any make / type and 1.5 / 2.0 ton capacity including making connection etc complete all as specified and directed by Engineer-in-Charge.
42Supply onlyremote control for split/window AC of existing make Complete all as specified and as directed by Engr-in-Charge.
43Supply and fixing ofswing motor, 230 v AC, 4-6 RPM for split/window AC of any make complete all as specfied and as directed.
44Supply and fixing offan motor for indoor unit of 1.5/2 Ton split ACComplete all as specified and as directed by Engr-in-Charge.
45Supply and fixingwater overflow PVC pipe heavy duty fixed on wall/floor of size15mm dia for water drainage.
46Supply and fixing ofcopper tubing 6mmto12 mm dia andthickness of copper tubing shall not be less than as per OEM.
47Taking out and refixing at another location window type/split typeAC 1.5 Ton/2 Ton including making hole in wall required sizeand making good disturb surface including electrical connection and testing of AC after installation complete all a specified and directed.
48M & Lin replacement of split Air conditioner outdoor unit wall mounting stand for suitable size of 1.5/2.0 TR split AC complete all as specified.
49DESERT COOLER Supply, fixing and connecting new fan motor,110 to 145watt single phase 230 volt 50 Hz copper wounded three speed suitable for desert cooler of 400/500 mm sweep sizecompleteincluding dismantling and removing of existing unserviceable fan motor with blades from the desert cooler of any make/type/capacity including removing of all fixing accessories etc and refixing the Fan motor with blades complete all as specified and directed by Engineer-in charge. Make -Crompton Greaves/Orient/Bajaj
50Supply and fixing in repalcement of old unsv/damage khas-khas pads for three sides, for desert cooler complete all as specified and directed by engineer-in-charge.
51Supply and fixing in replacement of old worn out/rusted desert cooler body frame of capacity 4000 Cum/Hr made of 20 gauge PGI sheet suitable for evaporative type desert cooler of size 67x67x87 cm including side panel - 03 Nos with 20 gause PGI sheet and water tank height 20 cm & grill with fins electrical wiring and connection with ON/OFF switch piano type with distribution PVC cup and elbow PVC pipe connection ,including duly painted complete body internally and externally and all side panel inner and outer side with two coat with synthetic enamel paint of approved colour over a coat of red oxide primer complete all as specified and as directed.
52Supply & fixing in repairs side shutter as per existing duly painted complete all as specified and directed by Engineer in Charge .
53Supply, Fixing in replacement of old unserviceable/damage submersible water pump with new submersible water pump , AC operated, single phase, capacity 12 to 18 watt , 240 Volts suitable for desert cooler and making necessary connection to power supply including flexible PVC tubing of required size,complete all as specified and directed byEngr-in-charge.
54Supply, Fixing in replacement of old unserviceable/ damage capacitor, 4 Mfd, 50Hz, complete all as specified and as directed by Engineer-In-Charge
55Supply, Fixing in replacemen of old unserviceable/ damage selector switch 3 speeds, 240 volts, 50Hz, complete all as specified and as directed by Engineer-In-Charge
56S&F in repairs switch piano type 5 Amp, flush type, single pole complete all as specified.
57Material and labour for scratching of old paint and rust by wire brush and applying two coats of spray paint of existingcolour/ as directed over one coat of primer ( red oxide ) including black bitumen paint at in side body of desert cooler complete all as specified and directed by Engineer-in charge.
58Supply & fix fan blades (Steel) for desert cooler in replacement as per sample all as specified.
59Supply & fix PVC water pipe of 15 mm dia with water distribution including replacement with PVC Elbows/junction/bend for desert cooler of any size.
60Supply & fix in replacementPVC cable flexible round/flat 3 Core Copper conductor cable 4 sqmm including taking out old unsv burnt out cable complete all as specified and directed by Engineer-in-charge.
61Supply & fix in replacementPVC cable flexible round/flat 3 Core Copper conductor cable 1.5 sqmm including taking out old unsv burnt out cable complete all as specified and directed by Engineer-in-charge.
62Supply & fix 3 pin Plug Top 15 Amp in replacement complete all as specified and directed.
63Supply & fix 3 pin Plug Top 5 Amp in replacement Complete all as specified and as directed by Engr-in-Charge.
64S&Fin replacement MCBs single pole (SP) 5 to 32 Amps with 10 KA breaking capacity of "C" series in distribution boards Complete all as specified and as directed by Engr-in-Charge.
65Dismantlingand taking out of voltage stabilizer of capacity 0.5 KVA to 5.0 KVA single phase 50 HZ detecting and rectifying faults and refixing , the repair of parts will be paid and measured seperately under relevant items complete all as specified and directed
66Dismantling of main transformer copper wound 160-250 volt stamping and material & labour for reassembling the stamping re-winding of main transformersinglephase 50HZ with supper enameled copper winding wire of correct size tums taping an vanishing of size 0.5 KVA to 3 KVA for PCB relay, resistance bakeilts mounted 2 to 3 pin connection with brass strip, Amp meter (0-30) Amps, Voltmeter(0-30)volts Kit Kat indicator and replacement to flexible wire 3 Core up to 40/0.0075 size round, cooper conductor and plug top 3 pin 5 to 15 Amps and reassembling testing complete all as specified and directed by Engineer-in-Charge
67Description all as per item No 66.00 but for 4 KVA to 5 KVA capacity.
68Supply & fix in replacement of Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 130 V to 270 volt with output voltage stabilized at 230 v with accuracy of+ 2.5 % and of cap 2/3 KVA having digital display to show input and output voltage Complete all as specified and as directed by Engr-in-Charge.
69Supply & fix in repair / replacement of Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 130 V to 270 volt with output voltage stabilized at 230 v with accuracy of+ 2.5 % and of cap 4 KVA having digital display to show input and output voltage Complete all as specified and as directed by Engr-in-Charge.
70Supply & fix in repair / replacement of Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 130 V to 270/300 volt with output voltage stabilized at 230 v with accuracy of+ 2.5 % and of cap 5 KVA having digital display to show input and output voltage
71Supply and fix in replacement push cock/ bib cock and stop cock chromium plated, for 15 mm bore pipe internal/external thread, suitable for water cooler of any type and any capacity, complete al as specified and as directed by Engineer-In-Charge.
72Taking out old unserviceable gate valve and supply and fix new 15 /20 mm dia bore gun metal gate valve conforming to IS with iron wheel head screwed both ends for iron pipe all as specified and directed.
73Supply and fixin replacement GI pipe Medium grade galvanized of15 mm dia bore size in any lengths laid in trenchs or laid on floors or fixed with walls with all fittings in such as tees, bend, elbows, sockets, reducer , connectors, back nuts, diminishing pieces, caps, plugs, nipples and union complete incl taking down old rusted/unserviceable pipe all as specified and directed.
74M&L in replacement of old unserviceable/ damage ball valve with new ball brass valves, high pressure, with polythene float and flynut, screwed for iron pioe or brass ferrule and fixed for 15mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
75M&L for Mild steel work as in stands/base usingangle sections in replacement including nuts, bolts, washers, welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified & directed.
76Material and labour for repair/servicing of water purifier , RO system , UF stabilized TDS controller of any make/ model through authorized service representative and replace the defective components and RO made functional, Minor items such as waste pipe,pvc connector,elbow etc shall be deemed to be included in quoted rate. Major complaints shall be measured and paid seperately as supply & fixing
77S&F membrane suitable for any make/model of RO.
78S& F candle for sedimentation filter
79S &Fcandle for pre/ post carbon filter
80S&Fbooster pump for RO complete all as specified and as directed
81S&Ft for TDS controller of RO complete all as specfed and as directed.
82Material and labor for replacement of unsv split AC indoor unit body, unsv AC junction box, unsv voltage relay , unsv blower fan and motor,burnt swing motor, unsv PCB and Evaporator and replacement of all filter complete make the AC serviceable all as specified and as directed.
83Supply and fix in replacement modular single phase motor starter , 230VAC, 25 Amp,2 module, panel mounting type as per existing make complete all as specifed and as directed.
84Material and Labour for replacement of unsv Split AC 1.5 Ton outdoor unit , unsv compressor, unsv fan motor with blade and unsv rusted outer body, and capacitor, unsv condenser replace all the unsv part and make the outdoor unit to serviceable condition complete all as specified and as directed.
85Taking down Exhaust Fan of any make & size from existing position of any height for repair, mainteance and refixing the same after neccesary repair complete all as directed. Notes (i) The defective parts to be replaced shall be measured and paid separately under relevant item of Sch . (ii)Cost of minor items i.e. Screws, nut & bolts etc shall be deemed to be included in the above item.
86S&F double ball bearing (ISI marked) including necessary greasing at site for exhaust fan of350/450mm sweep capacities.
87S&F double ball bearing (ISI marked) including necessary greasing at site for exhaust fan of300/250 mm sweep capacities.
88S&F Gun metal bush for Exhaust fan of any cap/ any size sweep complete.
89M&L for removing old burnt winding of exhaust fan/wall mounted fan of350/450mm sweep motor and rewinding the same with superior quality super enamelled copper wire of suitable size includinginsulation ,drying after varnishing complete all as directed and specified by Engr-in- Charge.
90M&L for removing old burnt winding of exhaust fan/Wall mounted fan of300mm/230mm sweep motor and rewinding the same with superior quality super enamelled copper wire of suitable size includinginsulation ,drying after varnishing complete all as directed and specified by Engr-in- Charge.
91S&F in replacement blade suitable for exhuast fan of 450mm/300/250 mm sweep of existing make complete all as directed and specified by Engr-in- Charge.
92S&F in replacement louvers shutter suitable for exhuast fan of 450mm/300mm/230mmsweepof existing make complete all as directed and specified by Engr-in- Charge.
93Taking down Ceiling fan of any make & sweep size by disconnecting clips,lock nuts etc. from existing position of any height,keeping in safe costudy for repair & mainteance.(Note: Repair & Maintance Shall be paid separetly under relevant items.)
94Hanging only ceiling fan 1200mm/1400mm sweep after repair & maintenance with existing down rod clips,lock nuts etc. Note:- (i)Refixing of repaired fan in any location of NAMS area with in distance of 5 Km shall be contractors responsiblility at his own arrangement of transport and tool and plant.(ii) cost of minor itemssuch as hanging clamp,split pin, steel screw,rubber reel etcincluded in quoted rate.
95M&L for rewinding of ceiling fan upto 1200/1400mm sweep AC230 volt with super enameled copper winding wire with an appropriate gauge and no of turns as originally designed by manufactures with all type of packing /insulatingmaterial varnishing including dismantling & reassembling after repair including cleaning andpainting of ceiling fan complete with synthetic enamel paint by spraying one coat after rewinding of the same and marking MES number and testing completeall as specified and directed by Engineer incharge.
96S&F bearing for ceiling fan 1200mm/1400mm sweep ISI marked including necessary greasing complete all as specified
97S&F Gun metal bush for ceiling fan 1200mm/1400mm sweep.
98S&F cup made of plastic complete with nut bolt for fixing in position suitable for ceiling fan 1200mm/1400mm sweep complete all as specified & directed.
99S&F blade suitable for 1200mm sweep Ceiling fan complete all as directed.
100S&F blade suitable for 1400mm sweep Ceiling fan complete all as directed.
101Supply and fixingmounting legs with rubber bush suitable for any type of exhaust fan complete all as specifed.
102Supply only ceiling fan down rod 15 mm bore, 300/400 mm long , factory made, colour brown/ white complete.
103S & F in repalcement flexible 2 core copper conductor cable of size 0.75 sqmm wire PVC insulated super conductor twin core for replacement from ceiling rose to ceiling/exhaust fan complete all as specified and directed.
104S&F of capacitor 2.5 mfd ISI marked complete all as directed.
105S&F of capacitor 3.15 mfd ISI marked complete all as directed.
106Taking downand refixing in PVC Exhaust Fan motor in replacement for 200/250 mm sweep , 230 volts 50 c/s of any make complete all as specified and directed.
107Taking downand refixing PVC Exhaust Fan blade in replacement for 200mm/250mm sweep 230 volts 50 c/s of any make completeall as specified and directed.
108Taking downand refixing PVC Exhaust Fanbody in replacement for 200/250mm sweep, 230 volts 50 c/sall as specified and directed.
109Supply and fixing in replacementof following sparesof PVC wall mounting fan ofexisting make 400mm sweep, 230v 50 Hz including making connectioncomplete all as specified and as directed. (i) Wall mounting fan body with selector switch -01 nos(ii) Wall mounting fan motor-01 nos(iii) fan blade-01 (iv) fan guard -01 nos
110Supply and fixing in replacementof following sparesof Pedestal fan ofexisting make 400mm sweep, 230v 50 Hz including making connectioncomplete all as specified and as directed.(i) Pedestalfan body with selector switch-01 nos (ii) Pedestal fan motor-01 nos (iii) fan blade-01 nos (iv) fan guard and stand -01 nos
111Taking down the stator of ceiling fan from site and carrying to workshop for remetalling and lathe work of shaft making it tooriginal shape and refixing at exisitng site complete all as specified and directed.
112Supply and fixing in reapir/replacement ofstepped type electronic fan regulator flush type all as specified and directed.
113S&F inreplacement of 3 pin socket suitable for sheet metal enclosure (industrial type DB) 20A complete all as speicified and directed .
114S&F inreplacement of 3 pin plug suitable for sheet metal enclosure (industrial type DB) 20A complete all as speicified and directed .
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail