Public Administrative Department Local Bodies Closing in 0 days TDR #37824262

Tender For Supply, Delivery, Testing And Commissioning Of Faulty Scada Instrument To Be Replacement Of Mandalam -Ii

Issued by Local Bodies · tiruchirappalli, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
30 May 2023
0 days left
EMD
26200
Bank guarantee accepted
Document Fee
7080
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tiruchirappalli → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply, Delivery, Testing And Commissioning Of Faulty Scada Instrument To Be Replacement Of Mandalam -Ii

BOQ

Name of Work: Supply, delivery, testing and commissioning of faulty SCADA instrument to be Replacement of Mandalam -II
Sl. No. Item Description
1Supply, Delivery, Installation and Commissioning of Pressure Transmitter along with installation accessories and with 4-20 mA Signal output for PLC connectivity at pumping following specifications.,Medium :Drinking Water, Pressure (min / max) :0 -10 BarTemperature (min / max) :-25 °C ... 70 °CType:CompactSENSOR ELEMENT:Measurement Method:Piezo resistive measurementProcess Temperature Limits: -25 °C ... 70 °CProcess isolating diaphragm design Internal Material process isolating diaphragm :316LElectromagnetic compatibility As per all the relevant requirements of the EN 61326 series including all taxesas directed by the Department officers
2Supply, Delivery, Installation and Commissioning of Ultrasonic level Transmitter along with installation accessories with 4-20 mA Signal output for PLC connectivity at all the OHT\"sfollowing specifications Type: UltrasonicPrinciple: Pulse Time of flightOutput 4-20 mA HART/Profibus Electromagnetic compatibility Interference emission to EN 61326;Ingress Protection :As per site condition Accuracy +/- 2 mm or 6 mm depending on selection or 0.2% of set measuring distance whichever is greater. Area Classification Non-Hazardous Temperature range -20°C ... +60°C Display :Builtin Alph numeric LCD display. Menu guided operation.Configuration Using Keypad on display SensorRange Liquids 0 to 5m depending on Tank size Temperature range -20°C ... +60°C ,Sensor: PVDF Seal: EPDMProcess connection Threaded or universal flange including all taxesas directed by the Department officers
3supply , delivery ,Installation and commissioning ofElectromagnetic flow meter conforming to ISO 17025 standard shall bea velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in units of kilolitres and shall be accurate within 0.5% of measured value, shall operate within a range of 0.3m/sec to 4m/sec and be constructed as follows: Meter tube(sensor) shall be fabricated from stainless steel and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber / polyurethane/PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil housing shall be fabricated from stainless steel/ ss304 /die cast aluminum /carbon steel with anticorrosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged for buried operation. Signal converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20mA output into minimum 500ohm load and a frequency output of a maximum of 0-10 KHz. The microprocessor based signal converter shall have a self diagnostic test mode and a backlit display that continuously displays \"Rate of flow\" and \"Total volume\". The signal converter housing should be die cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate should be provided by FCRI flow test lab / NABL accredited lab of OHT\"s IP 68 protect device.including all taxes extraas directed by the Department officers
4250 mm dia
5200 mm dia
6300 mm dia
7Actuator Repair of SCADA Based Valve Actuator Control System In the best hands Benefit from our solution. Our professional repair engineer of reliable and fault-free operation.We repair exactly what is needed with the utmost diligence and know-how.we often carry the requested spare parts. Repair at the Service engineer are professionally tested, maintained, and recalibrated.After RepairA. Reliable long-term operationB. Perfect actuator settingC. Complete Automation Operation as directed by the Department officers
8Torque switch
9potential transmitter
10Supply and Delivery of PLC unit with Operating voltage of24 V DC and with in built program memory back up, RTC, Adequate number of analog inputs & outputs, digital inputs & outputs along with PLC Panel with all internal wirings,24V DC power supply unit, 8 channel Solid state relays, terminal blocks etc., at following OHT locations with following minimum specifications Input Power: 24 VDC CPU Speed: 0.3 µs for Bool Instruction, 0.6 µs for Word Instruction Application Program Memory: 128 K bytes Flash Source Code Memory: 1 MB flash can Store Project File with Symbolic Names, Comments, Visualisation Screens Marker Memory: 32 K Points (4 K bytes) Data Memory : 24 K bytes Retained Memory: Stored in FRAM, Programming languages: Instruction List IL/Function Block Diagram FBD/ Ladder Diagram LD /Sequential Function Chart SFC/Continuous Function Chart (CFC) PLC system shall confirm to EN 61131-2 for operating & environmental conditions including all taxesas directed by the Department officers

AI Tender Summary

OUR REF NO 37824262
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 30-05-2023
Authority
Authority Name Tiruchirappalli City Municipal Corporation
Work Description Supply, Delivery, Testing And Commissioning Of Faulty Scada Instrument To Be Replacement Of Mandalam -Ii
Basic Detail
Tender No T.No. 67/2023-2024 Serial No.02
Bidding Type Tender
Location
City tiruchirappalli
State Tamil Nadu
Key Dates
Publish Date 24 May 2023
Submission Date 30 May 2023
Open Date 30 May 2023
Finance
Tender Value Ref. Documents
Tender Fee 7080
EMD 26200
Exemption Not Available
Document List
efda9246-26c6-404e-93cf-7efe3e81f6af.html
BOQ_378462.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 24, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
May 30, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 30, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

efda9246-26c6-404e-93cf-7efe3e81f6af.html

xls

BOQ_378462.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders