Tender For Repair / Maintenance Of Lt Distribution System Incl Repair Lt Panels, Apfc Panels At Mil Stn Dappar., dappar-Punjab

Military Engineer Services-MES has published Tender For Repair / Maintenance Of Lt Distribution System Incl Repair Lt Panels, Apfc Panels At Mil Stn Dappar.. Submission Date for this Tender is 19-06-2023. Overhead Line Tenders in dappar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

37813202
Corrigendum : Tender For Repair / Maintenance Of Lt Distribution System Incl Repair Lt Panels, Apfc Panels At Mil Stn Dappar.
Open Tender
Indian
Punjab
dappar
19-06-2023

Tender Details

Repair / Maintenance Of Lt Distribution System Incl Repair Lt Panels, Apfc Panels At Mil Stn Dappar.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-06-2023
2 15-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPARI/MAINTENANCE OF LT DISTRIBUTION SYSTEM INCL REPAIR LT PANELS, APFC PANELS AT MIL STN DAPPAR.
Sl. No. Item Description
1Disconnecting & taking out old unserviceable LT cable of any size all as specified and directed by Engr-in-Charge.
2Supply, laying, jointing, connecting, testing & commissioning UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty 1100 volts grade with standard aluminium conductor of cross sectional area 120 sqmm x 3.5 core all as specified and directed by Engr-in-Charge. NOTE - (a). The quoted rate is deemed to be inclusive of arranging respective shutdown, disconnection of cables, commissioning of feeder after the completion of job and inclusive of any minor spares and jobs required for the completion of the job. (b). The cost of excavation, returning, filling, removal and PCC cable covers will be measured and paid under relevant items of this schedule.
3All as per ser item No 2 here-in-before but size of LT under ground cable 95 sqmm 3.5 core all as specified and directed by Engr-in-Charge.
4All as per ser item No 2 here-in-before but size of LT under ground cable 50 sqmm 3.5 core all as specified and directed by Engr-in-Charge.
5All as per ser item No 2 here-in-before but size of LT under ground cable 35 sqmm 3.5 core all as specified and directed by Engr-in-Charge.
6All as per ser item No 2 here-in-before but size of LT under ground cable 25 sqmm 4 core all as specified and directed by Engr-in-Charge.
7Excavation in trenches in soft/loose/hard soil n exc 1.5 m wide and not exc 1.5 m in depth and getting out including forming bottom to required level or slope for laying pipes / laying of cable complete all as specified and as directed by Engineer-in-Charge.
8Returning filling in soft / loose soil in trenches including spreading, leveling and well ramming in 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.
9Removal of surplus soil to a distance n exc in 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
10Material and labour sand cushioning (dry sand) to underground cable for cable protection 23 cm thick in two layers (8 cm thick before laying of cables and 15 cm thick after laying the cable and punning down the sand to 18 cm thickness.). Complete all as specified and as directed by Engineer-in-Charge. (Note:- Only punned thickness 18 cm of sand shall be measured for payment purposes).
11Material and labour precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm all as specified and directed by Engr-in-Charge.
12Make bore to road width for providing GI pipe medium/light grade both end socketed for passing armoured cable complete all as specified and directed by Engr-in-Charge.
13Material and labour for galvanized iron tubing size 40 mm bore (Light grade) with all necessary fittings laid in trenches under road crossing or fixed on poles / walls / under floors for cable protection complete all as specfied and as directed.
14Material and Labourfor earthingwith galvanised iron earth plate of size 600x600x6mm thick buried directly in ground not less than 2.25m below normal ground level,earth plate packed on all sides with charcoal mixed with salt in alternate layers of 15 cm thickness connected by galvanised iron earth earth strip 32x6mm soldered & riveted to earth plate, galvanised iron earth strip will be provided by using 50mm bore galvanised iron pipe (light grade) earth plate to transformer body and neutralor test point of transformer, including flat iron clamp 25x3mm including bolts, nuts and washers complete including watering galvanised iron pipe 20 mm dia "Light grade" 2.5m long the earthing includes PCC pit including necessary earth works and disposal of surplus soil to a distance not less than 50m, chamber of PCC 1:4:8 type D-2 using 40mm graded stone aggregate, coping shall be of PCC 1:3:6 type C-I using 20mm graded stone aggregate, RCC pit cover 50mm thick in 1:2:4 type B-I using 20mm graded stone aggregate, reinforced with 8mm dia @ 15cm c/c complete all as shown on sketch No 3 of SSR-I of 2009 and as specified and as directed by Engr-in-Charge.
15Material and Labourearth continuity conductor GI of 32x6 mm of GI strip by means of bolts, nuts, check nuts and GI washers complete all as specified and directed by Engr-in-Charge.
16Material and Labour Synthetic insulating mat (rubber matting), ISI Marked suitable for 1100 Volts electrical grade 2mX1mX2mm thick chequered top, ISI marked to be laid in front of LT panel board complete all as specified and directed by Engr-in-Charge.
17Material and Labour for Danger notice boards of 1.6mm thick mild steel sheet, vitreous enamelled white,with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT 25x20cm size all as specified and directed by Engr-in-Charge.
18Material & Labour for application of two coats of aluminium paint on steel tubular/rail pole of 9/11/13/15 M long externally after removal of old paint, rust, dust, oil, grease or any other foreign deposits by paint removers or burning off by blow lamps, cleaning with scrapers and chemicals for removal of rust for any number of coats of any width or girth incl. numbering of poles in black base & white letters paint and including. painting five no. strips upto 30 cm on bottom of pole with black and yellow colour paint alternatelyall as specified and directed by Engr-in-Charge
19Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 25 to 50 sqmm, core outdoor type and taking down fault complete all as specified and directed by Engr-in-Charge.
20Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 70 to 120 sqmm, core outdoor type and taking down fault complete all as specified and directed by Engr-in-Charge
21Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 150 to 185 sqmm, core outdoor type and taking down fault complete all as specified and directed by Engr-in-Charge.
22Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 240 to 300 sqmm, core outdoor type and taking down fault complete all as specified and directed by Engr-in-Charge.
23Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, Supply & Fix MCCB FP, 36kA, 400 AMPS with Thermal - Magnetic Release Type Ics = 100% Icu, Adjustable Over Load setting: 0.4 -1.0 x In, Adjustable short circuit for each phase from 1.5 - 8 x In including spreader terminals .NOTE - Quoted rate is deemed to be inclusive of minor jobs and minor spares required for fitment of MCCB in the existing panel all as specified and directed by Engr-in-Charge.
24Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, Supply & Fix MCCB TP, 25kA, 250 AMPS with Thermal - Magnetic Release Type, Ics = 100% Icu, Adjustable Over Load setting: 0.4 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, including spreader terminalsall as specified and directed by Engr-in-Charge. NOTE - Quoted rate is deemed to be inclusive of minor jobs and minor spares required for fitment of MCCB in the existing panel all as specified and directed by Engr-in-Charge
25Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, Supply & Fix MCCB TP, 25 kA, 200 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, including spreader terminalsall as specified and directed by Engr-in-Charge. NOTE - Quoted rate is deemed to be inclusive of minor jobs and minor spares required for fitment of MCCB in the existing panel all as specified and directed by Engr-in-Charge
26Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, Supply & Fix MCCB TP, 25 kA, 160 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In,including spreader terminalsall as specified and directed by Engr-in-Charge. NOTE - Quoted rate is deemed to be inclusive of minor jobs and minor spares required for fitment of MCCB in the existing panel all as specified and directed by Engr-in-Charge
27Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, Supply & Fix MCCB TP, 25 kA, 100 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, NOTE - Quoted rate is deemed to be inclusive of minor jobs and minor spares required for fitment of MCCB in the existing panel all as specified and directed by Engr-in-Charge
28Disconnecting, dismantling and taking out old burnt unserviceable MCCB from LT distribution panels after arranging necessary electric shutdown, Supply & Fix MCCB TP, 25 kA, 63 AMPS with thermal magnetic release, Ics = 100% Icu, Adjustable Over Load setting: 0.8 -1.0 x In, Adjustable short circuit for each phase from 6 - 10 x In, including spreader terminalsall as specified and directed by Engr-in-Charge. NOTE - Quoted rate is deemed to be inclusive of minor jobs and minor spares required for fitment of MCCB in the existing panel all as specified and directed by Engr-in-Charge
29Material and Labour for inspection of LT FPB all connected accessories/components like MCCB/MCB/ACB ON-OFF/Tripping operations, metering devices, cable lugs joints, bus bar connections, insulators, wiring, CTs, etc., cleaning of LT FPB using dry air pressure, vacuuming out all dust/foreign particles using vaccum cleaner complete, removing flash over/burnt carbon particles from cable lug joints, bus bars, etc. with CRC 226 or WD14 or equivalent cleaner, tightening of nuts/bolts and other electric connections, disconnecting all incoming and outgoing connected cables, cutting off burnt portions, crimping with suitable size copper lugs and connecting up inclusive of replacement of cable glands (if any) all as directed at site by Engr-in-charge. Note:- (a). All spares like LED indicating lamps, ACB/MCCB/MCB, fuses with holders, voltmeter, ammeter, CTs, selector switches, copper/aluminium bus bar, control wiring, etc. required for replacement shall be measured and paid separately under relevant items of schedule here-in-after however the quoted rate is deemed to be inclusive of cost of cleaning agents, grease, cable lugs, cable glands, nut/bolt and washer combination all as approved by Engr-in-Charge. (b). The contractor has to arrange for electrical shutdown prior to carry own repairs.
30Material and Labour for sheet metal work for replacement of unsv. panel doors, bus bar cover, metering devices/relay mounting doors in complete alignment with panel"s existing doors with 3mm thick CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032 or of shade as specified incld. necessary cutting of MS sheet so as to incorporate old serviceable panel accessories like LED indicating lamps, volt/ammeter, selector switches, MCCB/MCB handles, etc. welding and fixing jobs and dismantling of unsv./rusted doors to the complete satisfaction and as directed and specified by Engr-in-Charge. NOTE - (a). The contractor has to arrange for electrical shutdown prior to carry own repairs. (b). The quoted rate is deemed to be inclusive of cost of hinges, panel locks, accessories required for flush fitting of old serviecable LED indicating lamps, volt/ammeter, selector switches, MCCB/MCB handles, etc. on the new door or any other materials required for fixing and proper operations of door.
31Supply and relplace existing u/s indicating lamp LED type suitable to operate on 230 volts AC Supply of R/Y/B colour as per site requirement all as specified and directed by Engr-in-Charge.
32Supply & fix in replacement Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input current measurement range 0-200 A, CT/PT site programmable including suitable size CTs (set of 3) - 04 Nos. (Outgoing feeders) all as specified and directed by Engr-in-Charge.
33Supply & fix in replacement Single function 3 phase LED voltmeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable including suitable size CTs (set of 3) - 04 Nos. (Outgoing feeders) all as specified and directed by Engr-in-Charge.
34Supply and replace existing u/s selector switch for voltmeter all as specified and directed by Engr-in-Charge.
35Supply and replace existing u/s selector switch for Ammeter all as specified and directed by Engr-in-Charge.
36Supply and replace existing unserviceable CT as that of existing ratio and model suitable for 3 phase supply all as specified and directed by Engr-in-Charge.
37Painting to electric control panel of E/M installations by cleaning the existing old paint with the help of mechanical tools such as wire brush, scraper and sand paper from the surface of panel and painting the prepared surface with two coat of synthatic enamel paint of approved shade over a coat of red oxide primer complete all as specified abd specified.
38Repairing/servicing of APFC panel board by replacing the all defective components with new components, re-wiring, cleaning, testing, reconnecting, re-installing and commissioning the APFC panel board complete all as specified and directed by Engr-in-Charge. (a). All new components,. required for replacement shall be measured and paid separately under relevant items of schedule here-in-after however the quoted rate is deemed to be inclusive of cost of cleaning agents, grease, cable lugs, cable glands, nut/bolt and washer combination all as approved by Engr-in-Charge
39Supply & fix in replacement APFC relay of 8 stage supply Voltage 415 V AC and current Input - 1A or 5 A with specs as - 3 Phase Current and Voltage measurement, PF display - 3 Digit after decimal, Individual harmonics measurement up to 31st order, Dual PF setting for Mains - DG application, Communication through Inbuilt MODBUS RS-485 Protocol all as specified and directed by Engr-in-Charge.
40Supply & fix in replacement APFC relay of 16 stage supply Voltage 415 V AC and current Input - 1A or 5 A with specs as - 3 Phase Current and Voltage measurement, PF display - 3 Digit after decimal, Individual harmonics measurement up to 31st order, Dual PF setting for Mains - DG application, Communication through Inbuilt MODBUS RS-485 Protocol all as specified and directed by Engr-in-Charge..
41Dismantling, supply and install, connect, test and commission of capacitor, 3 phase, Super Heavy Duty cylindrical type, self standing units, self healing property with MPP film with safety device in the form of pressure sensitive (over pressure) mechanical interrupter, 415/440V, 3 phase, 50 Hz, Capacity 5 KVAR, AC conformance to Standards IEC 60831-1 2/96, IS 13340 including testing, commisioning as in repairs complete all as specified and directed.
42All as per item no 41 above but 10 KVAR all as specified and directed by Engr-in-Charge.
43All as per item no 41 above but 20 KVAR all as specified and directed by Engr-in-Charge.
44All as per item no 41 above but 25 KVAR all as specified and directed by Engr-in-Charge.
45All as per item no 41 above but 48.50/50 KVAR all as specified and directed by Engr-in-Charge.
46Supply and fix in repairs power capacitor duty contactor 3 phase with auxilary switch block 415 volts suitable for 10 kVAR capacitor complete with connected switch gear/ components in various APFC panelsall as specified and directed by Engr-in-Charge.
47Supply & fix in repairs power capacitor duty contactor 3 phase with auxilary switch block 415 volts suitable for 15 kVAR capacitor complete with connected switch gear/ components in various APFC panels all as specified and directed by Engr-in-Charge.
48Supply & fix in repairs power capacitor duty contactor 3 phase with auxilary switch block 415 volts and Spreader Link Kit suitable for 25 kVAR capacitor complete with connected switch gear/ components in various APFC panelsall as specified and directed by Engr-in-Charge.
49Supply & fix in repairs power capacitor duty contactor 3 phase with auxilary switch block 415 volts and Spreader Link Kit suitable for 48.50/50 kVAR capacitor complete with connected switch gear/ components in various APFC panels all as specified and directed by Engr-in-Charge.
50Supply & fix in repairs NO element complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
51Supply & fix in repairs NC element complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
52Supply & fix in repairs Illuminated push button- RED complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
53Supply & fix in repairs Illuminated push button- GREEN complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
54Supply & fix in repairs 1.1 KV current transformer of ratio 150/5 complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
55Supply & fix in repairs 1.5 Sqmm multistranded copper FRLSH wire for control circuit complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
56Supply & fixin repairs 2.5 Sqmm multistranded copper FRLSH wire for control circuit complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
57Supply & fix in repairs 4.0 Sqmm multistranded copper FRLSH wire for control circuit complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
58Supply & fix in repairs 6 sqmm multistranded FRLSH copper flexible cable complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
59Supply & fix in repairs 10 sqmm multistranded FRLSH copper flexible cable complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
60Supply & fix in repairs 16 sqmm multistranded single core copper conductor (Flexible) PVC Insulated Heavy Duty Industrial Cables for control circuit complete in various APFC panels all as specified and directed by Engr-in-Charge.
61Supply & fix in repairs 35 sqmm multistranded single core copper conductor (Flexible) PVC Insulated Heavy Duty Industrial Cables for control circuit complete in various APFC panels all as specified and directed by Engr-in-Charge.
62Supply & fix in repairs 1.5 sqmm pin type lugs complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
63Supply & fix in repairs 6 sqmm pin/fork/round type lugs complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
64Supply & fix in repairs 6-32 A SP MCB, 10 kA "C" series, 240 V AC, 50 Hz complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
65Supply & fix in repairs 2 way selector adaptor 25 Amps complete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
66Dismantling old LT panel and Supplying, installing, testing and commissioning of APFC panel with heavy duty capacitor and MCCB as incomer of 160 kVAR factory fabricated of size and of technical specs adhereing to existing IEC 61439 Part 1 & 2 norms, floor mounted, IP 55 grade, indoor type Panel double door type LT cubical panel made out of1.6 MM thick CRCA MS sheet duly powder coated with Seimens grey shade RAL 7032, dust and vermin proof with suitable size TPN PVC sleeved aluminium bus bar, including aluminium bus bars for incoming and outgoing connections supported on glass fiber reinforced thermosetting plastic insulated support with lifting lugs of suitable size. Panel should be mounted/grouted PCC (1:4:8) type D2of size on as per the panel dimensions such that there should be 100 mm offsets complete. The bottom of the panel (space between bottom of panel and top of PCC foundation) shall be covered with CRCA sheet covering all the sides of the base frame duly painted with two coats of synthetic enamel paint of approved shade over one coat of red oxide primer. The panel should have following accessories fitted in :-INCOMER :- (i) MCCB 320 Amp. TP 36KA Thermal Magenetic - 01 Nos(ii) Rotary operating mechanism - 01 Nos(iii) Spreader suitable for 320 Amp MCCB TP - 02 Sets of three(iv) Automatic Power Factor Controller Relay 12/16 Stage - 01 Nos(v) Automanual Selector Switch 1 Pole 2 way - 01 Nos(vi) Amp. Meter digital Type - 01 Nos(vii)Amp Meter Selector Switch - 01 Nos (viii) Volt Meter Digital Type (0-500 Volt) - 01 Nos(ix) Volt Meter Selector Switch - 01 Nos(x) Phase indication light RED - 01 Nos (xi) Phase indication light Yellow - 01 Nos
67(xi) Phase indication light Yellow - 01 Nos (xii) Phase Indication LIGHT Blue- 01 Nos (xiii) Control MCB 6 Amp 10 KA - 06 Nos (xiv) Current Transformer 320/5A - 03 Nos OUTGOINGS:- 50 KVAR Capacitor Bank :- (i) MCCB 125 Amp TP 25 KA- 01 Nos (ii) ON Indication Light RED - 01 Nos(iii) OFF Indication Light GREEN - 01 Nos (iv) Red Stop Push Button with block - 01 Nos (v) Green Start Push Button with block - 01 Nos (vi) MDXL Heavy Duty Capacitor 415 Volt 50Kvar*1Nos - 50 Kvar (vii) Capacitor Duty Contactor suitable for 50 Kvar capacitor, 3phase, 415volts with NO+NC Auxiliary Contacts - 01 Nos 25 KVAR Capacitor Bank :- (i) MCB 63 Amp TP 10 KA - 03 Nos (ii) ON Indication Light RED - 03 Nos (iii) OFF Indication Light GREEN - 03 Nos (iv) Red Stop Push Button with block - 03 Nos (v) Green Start Push Button with block - 03 Nos 2.5 mm air gap between testing(vi) MDXL Heavy Duty Capacitor 415 Volt 25Kvar*3 Nos - 75 Kvar (vii) Capacitor Duty Contactor suitable for 25 Kvar capacitor, 3phase, 415volts with NO+NC Auxiliary Contacts - 03 Nos
6815 KVAR Capacitor Bank :- (i) MCB 32 Amp TP 10 KA - 01 Nos (ii) ON Indication Light RED - 01 Nos (iii) OFF Indication Light GREEN - 01 Nos(iv) Red Stop Push Button with block - 01 Nos (v) Green Start Push Button with block - 01 Nos (vi) MDXL Heavy Duty Capacitor 415 Volt 15Kvar*1 Nos - 15 Kvar (vii) Capacitor Duty Contactor suitable for 15 Kvar capacitor, 3phase, 415volts with NO+NC Auxiliary Contacts - 01 Nos 10 KVAR Capacitor Bank :- (i) MCB 25 Amp TP 10 KA - 01 Nos (ii) ON Indication Light RED - 01 Nos (iii) OFF Indication Light GREEN - 01 Nos (iv) Red Stop Push Button with block - 01 Nos (v) Green Start Push Button with block - 01 Nos(ii) ON Indication Light RED - 03 Nos (vi) MDXL Heavy Duty Capacitor 415 Volt 10Kvar*1 Nos - 10 Kvar (vii) Capacitor Duty Contactorsuitable for 10 Kvar capacitor, 3phase, 415volts with NO+NC Auxiliary Contacts - 01 Nos5 KVAR Capacitor Bank :- (i) MCB 16 Amp TP 10 KA - 02 Nos (ii) ON Indication Light RED - 02 Nos NO+NC Auxiliary Contacts - 03 Nos (iii) OFF Indication Light GREEN - 02 Nos
69(iv) Red Stop Push Button with block - 02 Nos (v) Green Start Push Button with block - 02 Nos (vi) MDXL Heavy Duty Capacitor 415 Volt , 5Kvar*2 Nos - 10 Kvar (viiii) Capacitor Duty Contactor suitable for 5 Kvar capacitor, 3phase, 415volts with NO+NC Auxiliary Contacts - 02 Nos Air Fan 6" - 02 NosAuxiliary contact - 10 Nos BUS BARS :- 200Amp, TPN 415Volts 3Phase 4Wire Color Coaded Aluminum busbars (for outgoings & Incomings)- 01 Set MISCELLANEOUS:- Nuts, Bolts, Washers, Ferul Numbers, Cable Ties, Tie Base, Copper PVC Control Wire, Power Wire, Copper, Thimbles, Panel Locks, I-Hooks, PVC Tape, Insulators, E-type, L-Type, Round Type, MCB Chanel, PVC Chanel, Connector Chanel, Connectors, Foam Ga - 01 Lot
70Material & Labour for dismantling old unserviceable LT panel along with disconnecting connected cables, supplying, installing, testing and commissioning of 415Volts 3Phase 4 Wire factory fabricated and tested all as per existing IEC 60439 Part 1, floor mounted, IP 55 grade, indoor type double doorLT cubical panel made out ofCRCA MS sheet 1.6mm thick duly powder coated with Seimens grey shade RAL 7032, dust and veremin proof with suitable size TPN PVC sleeved aluminium bus bar all including angle iron base frame of 40mmx40mmx6mm. Panel should be mounted/grouted on 150 mm thick PCC (1:4:8) type D2 below nearest ground level and should be with 400 mm offsets on all 04 sides of the panel complete and should be inclusive of following fitted in accessories :- A. INCOMING - (i) MCCB 315 Amps ,415 V 4 pole 35 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T including spreader terminals - set of 04 and direct rotary handle -01 No, Current transfomer 400/5A -01 Nos,Shunt Release as per OEM specifications and model- 01 Nos. B. OUTGOING - (ii) MCCB 100 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T Make : Cat pat No :including spreader terminals - set of 04 and direct rotary handle -02 No, Current transfomer 100/5A -01 Nos,Shunt Release as per OEM specifications and model- 03 Nos. (iii) MCCB 63 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&Tincluding spreader terminals - set of 04 and direct rotary handle -01 No, Current transfomer 100/5A -01 Nos,Shunt Release as per OEM specifications and model- 05 Nos.(vii) MCB TPN 63 amps- 02 nos (viii) LED indicators - R/Y/B 240 V AC - 11 Sets of three - outgoing feeders (iii) OFF Indication Light GREEN - 01 Nos (iv) Red Stop Push Button with block - 01 Nos (v) Green Start Push Button with block - 01 Nos (vi) MDXL Heavy Duty Capacitor 415 Volt 50Kvar*1Nos - 50 Kvar (vii) Capacitor Duty Contactor suitable for 50 Kvar capacitor, 3phase, 415volts with NO+NC Auxiliary Contacts - 01 Nos
71(ix) Multifunction meter with accuracy Class 1.0, Flush mounting 96 x 96 mm, CT/PT site programmable for measurement of V, A, PF, kW, kVA, Load hoursincluding suitable size CTs (set of 3) - 01 No. (01 NO. for Incoming feeder) (x) Single function 3 phase LED voltmeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmableincluding suitable size CTs (set of 3) - 08 Nos. (Outgoing feeders) (xi) Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmableincluding suitable size CTs (set of 3) - 08 Nos. (Outgoing feeders) (xii) MCB SP "C" series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function meters) and multifunction meter - 6 Nos.(xiii) Control wiring with suitable size PVC insulated single core copper conductor cable for LED lamps, MFMs, etc.
72All as per item no 66 above but with following specifications:-
73A. INCOMING - (i) MCCB 250 Amps ,415 V 4 pole 35 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&T including spreader terminals - set of 04 and direct rotary handle -01 No, Current transfomer 400/5A -01 Nos,Shunt Release as per OEM specifications and model- 01 Nos. D. OUTGOING - (ii) MCCB 63 Amps ,415 V 4 pole 25 KA 50 Hz with Ics =100% Icu & thermal magnetic adjustable type all as per L&Tincluding spreader terminals - set of 04 and direct rotary handle -01 No, Current transfomer 100/5A -01 Nos,Shunt Release as per OEM specifications and model site programmable for measurement of V, A, PF, kW, kVA, Load hours including suitable size CTs (set of 3) - 01 No. (01 NO. for Incoming feeder) (vi) Single function 3 phase LED voltmeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable including suitable size CTs (set of 3) - 09 Nos. (Outgoing feeders) (vii) Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable including suitable size CTs (set of 3) - 09 Nos. (Outgoing feeders) (viii) MCB SP "C" series 10kA 60-32 Amps as protection for LED lamps (01 No. each for set of 03 Nos. LED lamps, multifunction and single function meters) and multifunction meter - 6 Nos.
74Note for Item Nos 66 to 68 above:- a. Panel drawing must be approved prior to placing PO to the Panel manufacturer from the Engineer-in-Charge. b. To ensure safety, reliability and accountability of component co-ordination, all the major components such as circuit breakers, contactors and the enclosure system called for in this specification should preferably be from a single manufacturer. The OEM shall be preferably manufacturer of aforesaid components and switchgear.
75Repairing/servicing of APFC panel board ranging from 150 - 200 KVAR by replacing the all defective components with new components, re-wiring, cleaning, testing, reconnecting, re-installing and commissioning the APFC panel board complete all as specified and directed by Engr-in-Charge.
76All as per item 69 above but APFC panel board ranging from 100 - 150 KVAR all as specified and directed by Engr-in-Charge.
77All as per item 69 above but APFC panel board ranging from 50 - 100 KVAR all as specified and directed by Engr-in-Charge. NOTE FOR ITEM No - 69 to 71 Supply of cable lugs and cable tags are deemed to be included in the quoted rates.
78Supply & fix Plastic body Instrument Cooling axial fan of 120 x 120 x 38 mm size fitted complete within the panel including cutting of a suitable sized hole on the panel body and wiring with 1.5 Sqmm copper conductor cable and MCB SPN 6 Amps all complete incld disconnecting and dismantling the old one as per satisfaction of Engr-in-Charge.
79Dismantling old unserviceable cable ducts from within the panel, Supply & Fix PVC cable ducts of size of size 45x30 MM including drawing existing cable through the ducts and commissioning the panel all as directed and specified by Engr-in-Charge.
80Dismantling old unserviceable DIN Rails from within the panel, Supply & Fix DIN Rail for mounting of MCBs of rating 6 to 63 Amps and of poles - 2/3/4 all as directed and specified by Engr-in-Charge.
81Supply & fix in repairs 63 A TP MCB, 10 kA "C" series, 240 V AC, 50 Hzcomplete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail