Tender For Repair/ Maintenance To Certain Sub Station, Lt Distribution System Capacitor Banks And Other Allied Works At Nad Bheemunipatnam And Ins Karna And Repair/ Maintanance Of Security/ Street/ High Mast / Solar Light System And Another Connected, visakhapatnam-Andhra Pradesh

Military Engineer Services-MES has published Tender For Repair/ Maintenance To Certain Sub Station, Lt Distribution System Capacitor Banks And Other Allied Works At Nad Bheemunipatnam And Ins Karna And Repair/ Maintanance Of Security/ Street/ High Mast / Solar Light System And Another Connected. Submission Date for this Tender is 13-06-2023. Capacitor Bank Tenders in visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

37813139
Tender For Repair/ Maintenance To Certain Sub Station, Lt Distribution System Capacitor Banks And Other Allied Works At Nad Bheemunipatnam And Ins Karna And Repair/ Maintanance Of Security/ Street/ High Mast / Solar Light System And Another Connected
Open Tender
Indian
Andhra Pradesh
visakhapatnam
13-06-2023

Tender Details

Repair / Maintenance To Certain Sub Station, Lt Distribution System Capacitor Banks And Other Allied Works At Nad Bheemunipatnam And Ins Karna And Repair / Maintanance Of Security / Street / High Mast / Solar Light System And Another Connected Works At Tp Area, Non Tp Area At Ins Kalinga, Ins Karna, Nad Bheemunipatnam Visakhapatnam Under Ge ( P ) Navy Kalinga

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work : REPAIR/ MAINTENANCE TO CERTAIN SUB STATION, LT DISTRIBUTION SYSTEM CAPACITOR BANKS AND OTHER ALLIED WORKS AT NAD BHEEMUNIPATNAM AND INS KARNA AND REPAIR/ MAINTANANCE OF SECURITY/ STREET/ HIGH MAST / SOLAR LIGHT SYSTEM AND ANOTHER CONNECTED WORKS AT TP AREA, NON TP AREA AT INS KALINGA, INS KARNA, NAD BHEEMUNIPATNAM VISAKHAPATNAM UNDER GE (P) NAVY KALINGA
Sl. No. Item Description
1Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr in wide and not exc. 1.5m in depth for taking out / laying ofunder ground cable in trenches or cable ducts all complete all as specified.
2Returning, filling in including spreading, levelling, watering andwell ramming in layers, not exceeding 25 cm thick in soil after repairing / jointing and laying and testing of cables complete all as specified
3Removing surplus soil to a distance not exceeding 50 Mtr and deposited at a level not exceeding 1.5 mtr above from the starting point complete all as specified
4M&L natural river sand as cushioning of cables including spreading and punning down all as per clause No 19.75 of SSR part -I all as specified. Note : Punned thickness shall be measured for payment purpose
5Supply and lay un-reinforced precast concrete cable cover class LV, type 1, flat, size 250mmx150mmx40mm for protection of cable, laying in trenches complete all as specified and directed by Engr-in-charge.
6Labour charges for re-laying of serviceable bricks of any size and type recovered during taking out of old cable , over newly laid or re-laid cables all complete as specified and directed.
7M&L for cutting existing road / PCC drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with PCC 1:3:6 type CI using 20mm graded aggregates complete all as specified
8M&L for 50mm dia GI pipe medium grade galvanised for cable protection and sealing both ends including taking out old pipe complete all as specified.
9M&L for 80mm dia GI pipe medium grade galvanised for cable protection and sealing both ends including taking out old pipe complete all as specified.
10Taking down or out existing cable of sizes 2/3.5/4 core 10 sqmm to 70 sqmmfrom the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub stationincluding segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by Engineer in charge Note :(1) Excavation / cutting of road or floor/ GI pipe & laying / relaying of cableetc shall be measured and paid separately under respective item of this schedule
11All as per Item No 10 but cable of size 3.5 core 95 sqmm to 300 sqmm
12Relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 2/3.5/4 core 10 to 70 sqmm in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all asdirected and specified Note ;- Lugs and Glands will be measured and paid separately.
13All as per Item Sl No 12 above but of size 3.5 core 95 to 240sqmm
14Supply & Laying XLPE insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 16sqmm 4 core including necessary cable lugs, glands, insulation tapecomplete all asdirected and specified.
15All as per Srl item No. 14 here-in-before but of size10 sqmm 4 core
16All as per Srl item No. 14 here-in-before but of size25 sqmm 4 core
17All as per Srl item No. 14 here-in-before but of size35 sqmm 3.5 core
18All as per Srl item No. 14 here-in-before but of size 50 sqmm 3.5 core
19All as per Srl item No. 14 here-in-before but of size70 sqmm 3.5 core
20All as per Srl item No. 14 here-in-before but of size 95 sqmm 3.5 core
21All as per Srl item No. 14 here-in-before but of size120 sqmm 3.5 core
22All as per Srl item No. 14 here-in-before but of size150 sqmm 3.5 core
23M&L straight through joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty XLPE cables with aluminium conductor including jointing kit, including making joints for the cable of size 10-16 sqmm x 2/4 core cables including testing and commissioning complete all as specified
24All as per Srl item No. 23 here-in-before but of size 25 to 50sqmm x 3.5 / 4core, as per the size of existing UG cable.
25All as per Srl item No. 23 here-in-before but of size 70 to 120 sqmm x 3.5 / 4core, as per the size of existing UG cable.
26All as per Srl item No. 23 here-in-before but of size 150 to 185 sqmm x 3.5 / 4core, as per the size of existing UG cable.
27All as per Srl item No. 23 here-in-before but of size 240 to 300 sqmm x 3.5 / 4core, as per the size of existing UG cable.
28S&F in repair 400 A 4 Pole MCCB, 36/35 KA, 415V, 50 Hz, AC supply, Ics=100% Icu, adjustable Overload 80-100%, thermal magnetic release mechanism including necessary cable lugs & wire etc complete all as specified and directed.
29All as per Srl item No. 28 here-in-before but of capacity250 A 4 pole MCCB, Icu=35/36 KA.
30All as per Srl item No. 28 here-in-before but of capacity 200 A 4 pole MCCB, Icu = 25/26 KA.
31All as per Srl item No. 28 here-in-before but of capacity 125 A 4 pole MCCB, Icu = 18 KA.
32All as per Srl item No. 28 here-in-before but of capacity 63 A 4 pole MCCB, Icu = 18 KA.
33S&F in repair 3Ph LED Ammeter Cl 1digital type, 96X96 mm square Flush mounted case , Accuracy Class 1.0, with Inbuilt selector switch for 3 phase meters, Input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300 VAC, all complete with necessary wiring in the panelas specified and directed.
34S&F in repair 3Ph LED Voltmeter Cl 1, digital type, 0-500V, 96X96 mm square Flush mounted case Accuracy Class 1.0, with Inbuilt selector switch for 3 phase meters, Input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300 VAC, all complete with necessary wiring as specified and directed.
35S&F in repair of CT"s epoxy cast resin , with primary Current 400A - 650A or as per existing panel ratings suitable for relays and Secondary current5A , Dual core , Dual Ratio. Protection core-Class 5P10 & Metering core - Class 0.5 , 2.5 VA . Suitable for LT 415V panel incoming feeders.
36S&F in repair aluminium lugs suitable for 240 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed.
37All as per Srl item No. 36 here-in-before but for 185 Sqmm
38All as per Srl item No. 36 here-in-before but for 120 Sqmm,
39All as per Srl item No. 36 here-in-before but for 95 Sqmm,
40All as per Srl item No. 36 here-in-before but for 70 Sqmm,
41All as per Srl item No. 36 here-in-before but for 50 Sqmm,
42All as per Srl item No. 36 here-in-before but for 25 Sqmm,
43All as per Srl item No. 36 here-in-before but for 16 Sqmm Sqmm,
44M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground(earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth strip 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanisediron or steel all as shown in electrical plate No 3, connected to earthing point of outdoor panel boards all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel,complete all as specified and testing on completion.
45S&F in repair 250 A 4 Pole Change over switch, 50 KA, 415V, 50 Hz, AC supply, I - O - II operation, manual type, open construction or closed type construction as per site requirement, adjustable type of thermal and magnetic setting, handle,including necessary cable lugs & wire etc complete all as specified and directed.
46S&F in repair 160 A 4 Pole Change over switch, 50 KA, 415V, 50 Hz, AC supply, I - O - II operation, manual type, open construction or closed type construction as per site requirement, adjustable type of thermal and magnetic setting, handle,including necessary cable lugs & wire etc complete all as specified and directed.
47S&F in repair double compression weatherproof brass cable gland heavy duty , nickel plated of size OD 23mm-26mm (cable size 10/16 sqmm) all complete as specified and as directed Note: The quoted rate is inclusive of disconnecting the existing cable from electrical panel board and reconnecting it to the panel board after replacing the gland.
48All as per Srl item No. 47 here-in-before but of size OD 26mm - 30mm (cable size 25/35 sqmm)
49All as per Srl item No. 47 here-in-before but of size OD 33mm - 37mm (cable size 50/70 sqmm)
50All as per Srl item No. 47 here-in-before but of size OD 41mm - 46mm (cable size 95 / 120 sqmm)
51All as per Srl item No. 47 here-in-before but of size OD 52mm - 61mm (cable size 185/240 sqmm)
52M&L for dismantling the cable connections of3/4 pole Air circuit breakerof capacity 630 to 1000 Amps ,415 V 50 HZ of Any make, strip opening the Air circuit breaker, inspecting the parts for serviceability/ overhauling complete and carrying out the following repairs/maintenance :- (Srl item No. 52 is here-by continued as Srl item No. 52.10 to 52.90)
53a) Cleaning the insulation parts including bushings with CTC solution.
54b) Checking the alignment and condition of movable and stationary contacts and adjust them all as per manufacturer"s instructional manual
55c) Check the bolts, nuts, washers, cotter pins and all terminal connections are in place and tights. Replace the worn-out parts.
56d) Check arc chutes for damage and replace damaged parts.
57e) Clean and lubricate the operating mechanism with a light machine oil (SAE-20or 30) for pins and bearings and with a non-hardening grease for the wearing surfaces . Adjust breaker operating mechanism all as per manufacturer"s instructional manual . Replace if there is excessive wear and tear.
58f) Checking / inspectingshunt trip coil for serviceability and replacing the same if required.
59g) Replacing the badly worn or burned contacts. Checking control device free for operation.
60j) Check after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electricaloperation is functional
61Note : The rate quoted deemed to be inclusive of T&P and minor spares like lubricants, nuts/bolts/washers/ pins etc. Major spares like contacts, shunt trip coil , relays, CTsetc will be measured & paid separately under relevant schedule items
62S&F in repair XLPE insulated, armoured, earthed, heavy duty electric cable with Copper conductor , 1100 Volt grade, cross sectional area 16 sqmm 1 corecomplete all asdirected and specified.
63S&Fin repair XLPE insulated, armoured, earthed, heavy duty electric cable with Copper conductor , 1100 Volt grade, cross sectional area 35 sqmm 1 corecomplete all asdirected and specified.
64S&F in repair Copper lugs suitable for 16 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed.
65S&F in repair Copper lugs suitable for 35 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed.
66Supply only auxiliary contact block suitable for air circuit breakers of rating 400 to 1000 Amps rating as all per existing make.
67Supply only of Breaker Main Contact Setsuitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing make.
68Supply only of Spring charging handle assemblysuitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing make.
69Supply only of Shutter for guide framesuitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing make.
70Supply only of Overcurrent releasesuitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing make.
71Supply only of Front facia for drawout breakerssuitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing make.
72Supply only of arcing contacts (fixed/ moving)suitable for air circuit breakers of rating 400 to 1000 Amps rated as all per existing make.
73Supply only of arc chutes (for 415 V) suitable for air circuit breakers of rating 400 to 1000 Amps ratedas all per existing make.
74Supply only of closing coilsuitable for air circuit breakers of rating400 to 1000 Amps ratedas all per existing make.
75Supply only of trip coil suitable for air circuit breakers of rating400 to 1000 Amps rated all as per existing make.
76S&F in repair 300/320 A 4 Pole MCCB, 36/35 KA, 415V, 50 Hz, AC supply, Ics=100% Icu, adjustable Overload 80-100%, thermal magnetic release mechanism including necessary cable lugs & wire etc complete all as specified and directed.
77M&L for taking down high pressure SV/MV/MH/FTL/LED street light fittings and flood Light fittings of any wattage/ any height of pole/walls/ any location for repairs or replacement of burnt out the accessories and rectifying the fault etc. complete all as specified and as directed by the Engineer-in-Charge. Note: LED drivers, surge protection and cable etc. shall be measured separately under relevant items of this schedule.
78S&Fin repair LED street light fitting 45Watt 230 V AC outdoor type with high pressure die cast aluminium housing with heat resistant toughened glass & IP 65 protection luminaries of capacity 40 Watt complete all as specified and as directed by the Engineer-in-Charge. Make: Crompton Cat. Part No. LSTS-45-CDL-M or equivalent as approved by GE
79S&F in repairs, LED street light fitting pressure die cast aluminium housing with heat resistant toughened glass & IP 66 protection luminaries of capacity135 Watt complete all as specified and as directed by the Engineer-in-Charge. Make: Crompton Cat. Part No.LFLN-135-CDL/60-M or equivalent as approved by GE
80S&F in repair LED Flood light fitting pressure die cast aluminium housing with heat resistant toughened glass & IP 66 protection luminaries of capacity 150 Watt complete all as specified and as directed by the Engineer-in-Charge. Make: Crompton Cat. Part No. LFLN-150-CDL/60-M or equivalent as approved by GE
81Supply only drivers for LED street lights 45W/60W, 230 Volts, 50 Hz complete all as specified and as directed by the Engineer-in-Charge.
82Supply only drivers for LED street lights 100W/120W, 230 Volts, 50 Hz complete all as specified and as directed by the Engineer-in-Charge.
83Supply only drivers for LED flood lights 150W/200W, 230 Volts, 50 Hz complete all as specified and as directed by the Engineer-in-Charge.
84Supply and fixing PVC sheathed cable with stranded copper conductor of size 1.5 Sq.mm. 3 core, 1100 Volts grade, complete all as specified and as directed by the Engineer-in-Charge.
85S&F in repair digital time switches with battery back up 1100 hours with current capacity 16 A programmable every 1min with 1 changeover and total 28 programs complete all as specified and as directed by the Engineer-in-Charge. Make: Indoasian Cat. Part No. TDA43110 or equivalent as approved by GE
86S&F in repairs contactor ML-2 of capacity of 32 Amps AC 3 phase heavy duty including taking down old unserviceable contactor complete all as specified and as directed by the Engineer-in-Charge.
87S&F in repairs contactor ML-3 of capacity of 40 Amps AC 3 phase heavy duty including taking down old unserviceable contactor complete all as specified and as directed by the Engineer-in-Charge.
88S&F in repair timelite distribution board 32 Amps, 3 pole, 230 volts digital time switch complete all as specified and directed by Engineer-in-Charge. Make: Indoasian cat No. TL032DB0 or equivalent as approved by GE
89M&L for cleaning the swaged steel tubular street light poles of 9/11 meters height including GI pipe of street light fitting and preparation of surfaces by cleaning including scrapping up old corroded paint/dirt/dust/rust carefully and applying two coats of aluminium paint over one coat of metal primer and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of synthetic enamel paint including writing of pole numbers and two coats of colour washing on PCC coping surfaces complete all as specified and as directed by the Engineer-in-Charge.
90M&L for cleaning the pre-stressed cement concrete street light poles of 9/11 meters height, preparing old plastered or unplastered surfaces and applying two coats of cement based paint over one coat of primer including writing of pole numbers and two coats of colour washing on PCC coping surfaces complete all as specified and as directed by the Engineer-in-Charge.
91S&F GI bracket suitable for street light fitting made out of 40mm dia. GI tubing of light grade bent to shape of 1.5m length complete including taking out old one complete all as specified and as directed by the Engineer-in-Charge.
92Supply and laying LT underground cable XLPE insulated and sheathed armoured cable 1100 Volts grade of size 4 core 16 Sq.mm. aluminium conductor in trenches/poles and connecting with all accessories including taking out the old unserviceable cable complete all as specified and as directed by the Engineer-in-Charge.
93supply and laid pipes galvanized light grade for cable protection complte of 40 mm dia complete including taking down old unserviceable pipe .
94S&F HOT moulded (FRP) jucntion box for street light pole with locking arrangementt with IP-65 protection of size 250x250x150mm with 32 Amp 4 way heavy duty terminal block with 10 Amps MCB SP and two steel bracket to fix with pole complete all as specified and as directed by the Engineer-in-Charge. Make: Hansel/Sintex
95S&F in repairs, MS clamps suitable for 40mm GI pipe made out of 25x4mm flat iron complete with necessary nuts and bolts complete all as specified and as directed by the Engineer-in-Charge.
96S&F rigid non metallic PVC conduit 20mm dia. including all the fittings like Tees, bends, elbows, reducers etc. and fixtures such as couplers, lock nuts, saddles, pipe hooks etc. complete including taking down old one complete all as specified and as directed by the Engineer-in-Charge.
97M&L for repairs and maintenance of LED solar lights with charging and topping up distilled water in solar light batteries to maintain necessary specific gravity with replacement of damaged battery lead clamps andworn out leads including taking down and fixing of batteries to its position complete all as specified and as directed by the Engineer-in-Charge.
98Taking down high mast light of size 12/15/16 mtr from its base with help ofcrane, cleaning, greasing, and overhauling of all moveable parts like pullies,steel wire,chain,winches etc,replace unserviceable light if required and refix the mast on its original position complete all as specified and as directed by the Engineer-in-Charge.
99S&F in repairs of Aviation lightcomprising aluminium housing and polycarbonated enclosure at any height and location complete all as specified and as directed by the Engineer-in-Charge. Make:-Bajaj/Havells/Crompton/C&S
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,