Tender For Repair Maintenance Of Cool Room Cold Room Window Split Ac Water Cooler And Deep Freezer At Blo Hq Gna Gmk 2W Det Ncb And Inhs Jeevanti Under Ge Gomantak Vasco, vasco-Goa

Military Engineer Services-MES has published Tender For Repair Maintenance Of Cool Room Cold Room Window Split Ac Water Cooler And Deep Freezer At Blo Hq Gna Gmk 2W Det Ncb And Inhs Jeevanti Under Ge Gomantak Vasco. Submission Date for this Tender is 09-06-2023. Air Conditioner Tenders in vasco Goa. Bidders can get complete Tender details and download the document.




Tender Notice

37811427
Corrigendum : Tender For Repair Maintenance Of Cool Room Cold Room Window Split Ac Water Cooler And Deep Freezer At Blo Hq Gna Gmk 2W Det Ncb And Inhs Jeevanti Under Ge Gomantak Vasco
Open Tender
Indian
Goa
vasco
09-06-2023

Tender Details

Repair Maintenance Of Cool Room Cold Room Window Split Ac Water Cooler And Deep Freezer At Blo Hq Gna Gmk 2W Det Ncb And Inhs Jeevanti Under Ge Gomantak Vasco

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-May-2023 amendment1 BOQ 09-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 55000.0 /-
Tender Value
INR 27.48 Lakhs /-

BOQ Items

Name of Work : Repair/ Maintenance of Cool Room/ Cold Room,Window, Split AC, Water Cooler and Deep Freezer at BLO, HQ GNA, GMK, 2W Det, NCB and INHS Jeevanti under GE Gomantak Vasco
Sl. No. Item Description
1Material andLabour for servicing of following appliances comprising of thorough cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for the following:-
2(a) Water coolers 40 to 150 ltrs cooling capacity.
3(b) Refrigerator of 165 to 310 ltrs capacity.
4(c) Deep Freezers 200 to 425 ltrs capacity
5Supply andcharging refrigerant gas R-12/R-134up to required level incl connected works like pressure testing with nitrogen before filling refrigerant gas including leakage testing if any complete all as specified and directed by Engr-in-Charge
6(a) Water coolers 40 to 150 ltrs cooling capacity.
7(c) Deep freezers of 200 to 425 ltrs capacity.
8(d) Refrigerators of any capacity.
9Supply and replace compressor sealed unit of the following appliances of any make complete including replacement of copper tubing/capillary strainer etc, testing and commissioning all as specified and as directed by Engr-in-Charge. Make :Emerson,Kirloskar,Voltas
10(a)Water coolers of capacity 40/150 liters.
11(b) Refrigerators of capacity 165 to 310 ltrs.
12(c) Deep freezers 200 to 425 ltrs capacity.
13Supply and replace starting relay suitable for :- Make : as per exiting make
14(a) Water coolers 40 to 150 ltrs cooling capacity
15(b) Refrigerator of 165 to 310 liters capacity.
16(c) Deep freezers of 200 to 425 ltrs capacity.
17Supply and replace thermostats of :-Make : as per exiting make
18(a) Water coolers 40 to 150 ltrs cooling capacity.
19(b) Refrigerator of 165 to 310 ltrs capacity.
20(c)Deep freezers of 200 to 425 ltrs capacity.
21Supply and replace condenser unit of the following appliances including making of all connections as specified and directed by Engr-in-Charge. Make : as per exiting make
22(a) Water coolers 40 to150 ltrs capacity.
23(b) Refrigerator of 165 to 310 ltrs capacity.
24(c) Deep freezers of 200 to 425 ltrs ltrs capacity.
25Supply and replace cooling coil of :-
26(a) Water coolers 40 to150 ltrs capacity.
27(b) Refrigerator of 165 to 310 ltrs capacity.
28Supply and replace top cover gasket of water cooler 40 to 150 ltrs capacity.
29Supply and replace overload protector of :-Make : as per exiting make
30(a) Water coolers/ Refrigarator upto 350 ltrs cooling capacity.
31(b) Deep freezers of upto 425 ltrs capacity.
32Supply and replace ball brass valve, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferruleMake : Leader, Jindal or equivalent
33(a) 15mm dia
34(b) 20mm dia
35Supply and fix PVC insulated and overall PVC sheathed circuler flexible3 core 4 sqmm copper conductor cable including disconnecting and removal of old cable . Plaza / Findese or equivalent
36Supply and replace blower/condenser fan motor complete with necessary mounting bracket to and base frames for :-Make : as per exiting make
37(a) Water coolers of any make and40 to 150 ltrs capacity.
38(b) Deep freezers of any make & cap 200 to 425 ltrs
39Supply and fixing of16 mm CPVC pipes SDR 11 and plain CPVC SDR 11 fittings on wall/ ceilings or laying on floors complete all as specified
40All as per item no 13 as above but for20 mm bore
41Supply and Fixing in repair Gun metal Globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed in pipe including taking out existing unserviceable globe or gate of valves.Make : Leader, Jindal or equivalent
42(a) 15mm dia
43(b) 20mm dia
44Supply and Fixing bib taps, cast copper alloy with crutch or butterfly handle, screwed for iron pipe or for brass furrulesuitable for water cooler of any capacity including taking down existing bib tap Make : Jaquar,johnson,hindustan
45(a) 15mm dia
46(b) 20mm dia
47Dismantling and removing of defective burnt motor from unit and rewinding the motor with super enamel copper winding wire including replacement of worn out motor bearing, refixing and testing all as deirceted by Engr-in-Charge for the following appliances:-
48(a) Water coolers any make and capacity 40 to 150 ltrs .
49(b) Deep freezer of any make of 200 to 425 ltrs capacity.
50Supply and replace internal wiring complete suitable for following appliances.:-Make : as per exiting
51(a) Water Coolers 40 to 150 ltrs capacity.
52(b) Deep freezer of any make of 200 to 425 ltrs capacity.
53Supply andcharging refrigerant gas R-22/R-32up to required level incl connected works like pressure testing with nitrogen before filling refrigerant gas complete all as specified and directed by Engr-in-Charge. Make Paragon,Mefron(Note : Above secondfloor contractor willarrange crain / scaffolding with safety device)
54(a) Window type AC of capacity 1/1.5 Ton.
55(b) Split type AC 1.5/2.0 Ton capacity
56M&L for servicing of Split type AC 1.5/2 Ton capacity comprising of thorough cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation.(Note : Above secondfloor contractor willarrange crain / scaffolding with safety device)
57Preparation of old painted surfaces of Split type AC 1.5/2 Ton Capacity, painting with two coats of synthetic enamel paint by spraying as directed by Engr-in-Charge.(Note : Above secondfloor contractor willarrange crain / scaffolding with safety device)
58Supply and replace compressor sealed unit of the following appliances of any make complete including replacement of copper tubing/capillary strainer etc, testing and commissioning all as specified and as directed by Engr-in-Charge. (Note : Above secondfloor contractor willarrange crain / scaffolding with safety device) Make : Emerson,Kirloskar,LG
59(a) Window type AC of capacity 1/1.5 Ton.
60(b) Split type AC 1.5/2.0 Ton capacity.
61Supply and replace capacitors of the following capacities for ACs Make :Siemens,epcos or equivalent
62(a) 4/6 Mfd
63(b) 10 Mfd
64( c) 36 Mfd 6 pin
65(d) 80/100 Mfd
66(e) 120 Mfd
67(f) 45+6 Mfd Seven Pin
68Replace after cutting of worn out bottom portion and fabricated / welded properly of bottom tray with suitable size of GI plate of Split type ACs any capacity and make and welding of legs including supply fixing suitable size of angle iron legs of any make complete all as specified and as directed by Engr-in-Chrge.
69Supply and replace starting relay suitable for Split type AC 1.5/2 Ton capacity
70Supply and replace thermostats of Split type AC 1.5/2 Ton capacity.
71Supply and replace overload protector of Split type AC 1.5/2 Ton capacity.
72Supply and replace copper condenser unit of Split type AC 1.5/2 Ton capacity including making of all connections as specified and directed by Engr-in-Charge Make :.LG,Voltas,Whirpool .
73Supply and replace ofevaporator coil of Split type AC 1.5/2 Ton capacity.Make : as per exiting
74Supply & Fixing submain wiring with 2 Runs of 4 Sqmm, PVC insulated, unsheathed, single core, multi stranded, 1100 volts, copper conductor cable drawn in and including 25/32mm wide PVC casing and caping with all accessories such as tees, elbows, juction box, reducers etc as required along with 1 run of 4 sqmm PVC insulated, unsheathed, single core, multi stranded coper conductor cable as continuous earth wire and connecting to existing main switch board/Distribution Board and testing on completion including taking down old submain wiring of any type with conduit comlete all as directed by Engineer-in-Charge. Note : 3 runs of 4 Sqmm cable, and 1 run of PVC casing/caping 25mm/32mm wide shall be measured as single run. Make poly cab/Anchor/V- guard
75Supply and fixing of DBOXX protected socket AC box woth one sigle pole MCB 240 volts 20 Amp. Make :. Havells/Anchor/Legrand
76Supply and replace MCB SP 5 to 30 Amps 250 Volts. Make Legrand,L&T,C&S
77Supply and replace contact unit of split type AC of 1.5/2 Ton cap.Make : as per exiting
78Supply and replace internal wiring but complete suitable for Split type AC of any make and capacity 1.5/2ton.
79Dismantling and removing of defective burnt motor fromSplit type AC of any make and capacity 1.5/2 ton and rewinding the motor with enamelcopper winding wire incl replacement of worn - outmotor bearing ,refixing and testingall as directed
80Supply and replace blower/condenser fan motor complete with necessary mounting bracket to and base frames for Split type AC of any make and capacity 1.5/2 ton :- Make : as per exiting
81Supply and replace indoor fan unit complete suitable for cool room / cold room with existing make and capacity all as directed by Engr-in Charge :- Make : as per exiting
82Supply and replace heavy duty PVC flexible pipe with necessary fittings of jubilee /split ACs/Window ACs drains of 15mm dia bore.
83Supply and fix Air fillter suitable for 1.5/2.0 ton splittype AC
84Supply and fix insulation for copper tubes of split type AC units,insulation type superion of size 3/8"diameter
85Supply and fix insulation for copper tubes of split type AC units,insulation type superion of size 5/8"diameter
86Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 5/8" dia
87Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 3/8" dia
88Taking down of Split type AC (Indoor & out door with mounting bracket & voltage stabilizer) of any capacity from existing place and Reinstall the same in another location complete and testing & commisioningall as specified and directed by Engr-in - charge.(Note : New spares required for replacing (mounting bracket,insulation for copper and copper tubing) shall be measured and paid seperately).
89Supply and fix PCB(circuit board) complete suitable for 1.5/2.0 ton capacityInverter type split AC indoor unit. Make: LG ,Voltas,Daikin
90Supply and fix PCB(circuit board) complte suitable for 1.5/2.0 ton capacity Inverter type split AC out door unit. Make: LG ,Voltas,Daikin
91Supply and fix PCB complte suitable for 1.5/2.0 ton capacitysplit type AC. Make LG ,Voltas ,Daikin
92Supply & Fixheating element of cold room door of existing make, capacity and size for the entire satisfaction of Engr in Charge
93Supply & Fixthermostat of heating element of cold room door of existing make, capacity and size for the entire satisfaction of Engr in Charge
94Supply & Fixhandle with locking facility of cold room door of existing make, capacity and size for the entire satisfaction of Engr in Charge
95Supply and fix in repair MS stand factory made for installation of condensing unit on the wall/ ground duly powder coated all as per requirement complete all as specified and as directed by Engineer in charge
96Supply and fix in repair Remote control of any size and capacity of split AC . Make: as per existing.
97Supply and fix in repair Voltage stablizer capacity of 5 KVA of range 130V to 280 V suitable for upto 2 ton Split AC . Make: V-Guard,Micro Tec/ Volina/ Aplab
98Supply and fix in repair indoor cooling unit with rotary fan suitable for 1.5 ton Split AC . Make: LG ,Voltas,Daikin
99Supply and fix in repair indoor cooling unit with rotary fan suitable for 2 ton Split AC . Make: LG ,Voltas,Daikin
100Supply and fix in repair Out Door unit with rotary fan suitable for 1.5 ton Split AC . Make LG ,Voltas,Daikin
101Supply and fix in repair Out Door unit with rotary fan suitable for 2 ton Split AC . Make LG ,Voltas,Daikin
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail