Tender For Provn Of Three Phase Connection With Allied Services As Per New Map Provision In Officers Md Accn Of Bhagat Enclave, Replacement Of Existing Conventional Electric Energy Meter Into Smart Prepaid Energy Meters In Jco Md Accn In Ah Enclave, ganganagar-Rajasthan

Military Engineer Services-MES has published Tender For Provn Of Three Phase Connection With Allied Services As Per New Map Provision In Officers Md Accn Of Bhagat Enclave, Replacement Of Existing Conventional Electric Energy Meter Into Smart Prepaid Energy Meters In Jco Md Accn In Ah Enclave. Submission Date for this Tender is 08-07-2023. Energy Meter Tenders in ganganagar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

37811277
Corrigendum : Tender For Provn Of Three Phase Connection With Allied Services As Per New Map Provision In Officers Md Accn Of Bhagat Enclave, Replacement Of Existing Conventional Electric Energy Meter Into Smart Prepaid Energy Meters In Jco Md Accn In Ah Enclave
Open Tender
Indian
Rajasthan
ganganagar
08-07-2023

Tender Details

Provn Of Three Phase Connection With Allied Services As Per New Map Provision In Officers Md Accn Of Bhagat Enclave, Replacement Of Existing Conventional Electric Energy Meter Into Smart Prepaid Energy Meters In Jco Md Accn In Ah Enclave And Provis

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Jun-2023 Revised DATE Date 24-06-2023
2 16-Jun-2023 Revised DATE1 Date 01-07-2023
3 01-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-07-2023

Key Value

Document Fees
INR 1000 /-
EMD
INR 174550.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: PROVN OF THREE PHASE CONNECTION WITH ALLIED SERVICES AS PER NEW MAP PROVISION IN OFFICER"S MD ACCN OF BHAGAT ENCLAVE, REPLACEMENT OF EXISTING CONVENTIONAL ELECTRIC ENERGY METER INTO SMART PREPAID ENERGY METERS IN JCO MD ACCN IN AH ENCLAVEAND PROVISION OF SERVER ALONGWITH ALLIED ITEMS FOR MERTERING SYSTEM AT MILITARY STATION SRIGANGANAGAR
Sl. No. Item Description
1Excavation in trenches, not exc. 1.50 mtr wide and not exc 1.50 mtr in depth and getting out in soft / loose soil for foundations complete all as specified and directed by Engineer - in -Charge.
2M & L for PCC (1:4:8) type D-2 ( using 40mmgraded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed by Engineer - in -Charge.
3M&L for form work on flat surfaces, rough finish to sides of concrete foundations, footings, bases of columns, raft beams sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter complete all as specified and directed by Engineer-in-Charge.
4M&L for RCC M-25 (Design mix) using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams, plinth beams, base for columns, etc basements slabs under rammed piles and mass concrete complete all as specified and directed by Engineer - in -Charge.
5M&L for formwork to sides of pillars Square, Circular rectangular on plan or polygonal posts, struts, piers, columns and stanchions complete all as specified and directed by Engineer - in -Charge.
6M&L for RCC M-25 (Design mix) using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and strutscomplete all as specified and directed by Engineer - in -Charge.
7M&L for form work for rough finished flat surface of concrete to roof beams, beam haunching, girders, lintels etc. also splays between floors and beem complete all as specified and directed by Engineer - in -Charge.
8M&L for RCC M-25 (Design mix) using 20 mm graded stone aggregate as in Beams cantilevers, bressummers lintels over 1.5 m span complete all as specified and directed by Engineer - in -Charge.
9M&L for formwork to soffits of suspended slabs such as roof slabs,floor slabs thickness n. exc. 200 mm(horizontal or sloping) in rough finish complete all as specified and directed by Engineer - in -Charge.
10M&L for Formwork to edges of concrete flats and similar worksthickness n. exc. 200 mmwide in rough finish complete all as specified and directed by Engr-in-Charge.
11M&L for RCC M-25 (Design Mix) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-in-Charge.
12S & F TMT bars 10mm diaand over cut to length bent to shape required , incl cranking , bending spirally for hoping for columns , hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer - in -Charge.
13All as per item No. 12 above but 5mm dia and over upto and including10mm dia as in stirrups, spacers and binders complete all as specified and directed by Engineer - in -Charge.
14M&L for brick work with sub class `B` old size bricks straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
15M&L for 15mm thick rendering in CM (1:4) to brick/ concrete wall surfaces finishedeven & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
16M&L for 15mm thick rendering in CM (1:6) to brick/ concrete wall surfaces finishedeven & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
17M&L for 5 mm thick rendering in CM (1:3) to concrete surfaces of ceiling finishedeven & smooth without using extra cement complete all as specified and directed by Engineer - in -Charge.
18M & L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over 3mm thick wall putty complete all as specified and directed by Engineer - in -Charge.
19M&L for preparation ofnewly plastered surface of wall any description and applying twocoats of oil emulsion distemper over 3 mm thick wall putty over a coat of chalk whiting layer on plastered surfaces complete all as specified and directed by Engineer - in -Charge.
20M & L for three coats of white washing on newly plastered surfaceson ceilingincluding preparation of surface complete all as specified and directed by Engineer - in -Charge.
21M&L for 75 mm thick PCC (1:3:6) type C-1 using 40 mm graded crushed stone aggregate as in plinth protection, hard standing finished cement concrete surface even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
22M&L for cement concrete type B1, (1:2:4), using 20 mm gradded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed by Engineer - in -Charge.
23M&L for earth filling, spreading and levelling in layers n exc. 25 cm thick complete all as specified and directed by Engineer - in -Charge.
24M&L hardcore of broken stone or boulders gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer - in -Charge.
25M&L for 75 mm thick plain cement concrete (1:4:8) type D-2, using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed by Engineer - in -Charge.
26M&L for Non skid coloured ceramic tiles (Jointless) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but n exc 0.18 as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed by Engr-in-Charge.
27M&L for glazed ceramic coloured tiles 600 x 300 x 7 mm thick jointless tiles as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified and directed by Engr-in-Charge.
28Returning filling in incl spreding levelling watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer - in -Charge.
29Removing excavated soil not exc. 50 mtr and depositing where directed at a level n. exc. 1.50 mtr above the starting point complete all as specified and directed by Engineer - in -Charge.
30S&Fpowder coated coloured anodised aluminium frames for doors, windows with one or more rebates including jointing cleates for fixing etc complete all as specified and directed by Engineer - in -Charge.
31S & F powder coated coloured anodised aluminiumwindowsand ventilator shutters, side hung type, without sash bars aluminium saction weighing 0.55 kg/sqm including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fitting such as peg stay 150mm long (01 No) hinges type B21 100 mm long (03 Nos) suitable handle (02 Nos) complete all as specified and directed by Engineer - in -Charge.
32S&F Anodised aluminum grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15 ) of approved design /pattern, with approved standard section and fixed to the window /doorwith C.P brass/SS screw @ 200mm centre to centre , including cutting the grill to proper opening size for fixing and operation of handles complete all as specified and directed by Engineer - in -Charge. Note:- (i) Design shall be approvedby Engineer - in - Charge. (ii)Minimum thickness of powder coating shall not be less than 50 micron.
33S&F aluminum alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-charge
34S& F powder coated anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges,anodised aluminum snap beading screws,tower bolt (02 Nos) etc complete all as specified and directed by Engineer-in-charge
35S & F brass mortice lock, vertical type, size 100 mm and 4 lever type complete all as specified and directed by Engineer-in-charge
36S&Fdoor closer (extruded section body) hydraulically regulated, alunimiunbody designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed complete all as specified and directed by Engineer-in-charge
37S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed by Engineer-in-charge
38S&Fanodised aluminium snap grid frame work for false ceiling including hangers complete all as specified and directed by Engineer-in-charge
39S&F Gypsum boardof size 600 x600 x12 cm thick for false ceiling panel or tiles for insulation and accoustic purposes, 60 cm x 60 cm in size laid/inserted to timber/GI/Aluminium framework with screwscomplete all as specified and directed by Engr-in-Charge.
40S & F for 5.5mm thick sheet glass(tinted),selected quality and glazing with necessory arrangement in square exc 0.5 sq. m in each pane complete all as specified and directed by Engr-in-Charge.
41M&L for 100mm dia cast iron sand cast waste and vent pipes in any length with or without ears with cement jointed fixed to wall complete all as specified and directed by Engr-in-Charge.
42M&L for Roof treatment to RCC roof as follows:- (a) Cleaning the roof surfaces thoroughly using wire brusehes to remove sharp projections, cleaning joints, washing, drying and removing all dirt/dust to receive concrete padding/plaster etc. (b) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:4) with WPC, finished even and smooth without using extra cement. (c) Providing one coat of approved bituminous primer @100 gms per sqm, over dried plastered surface. (d) Laying 3 mm thick APP membrane,(mineral finish) minimum weight 3kg/sqm reinforced with non woven polyster fabric(weight not less than 150 gms/sqm), by torch application. The overlapping while torching shall be 75 mm on longitudinal direction and 100 mm on the transverse direction complete all as specified and directed by E-in-Charge. Notes:- (i) All joints and change in directions should be covered wih cement mortar (1:3) mixed with SBR latex @ 200 ml/bag of cement/as per site reqmt and cured well before laying membrane by torching. (ii) All angles and abuttments should be sealed well with extra care to ensure full bondage. (iii) Water proofing treatment shall be got carried out by approved authorised applicator of manufacturer only. The name of firm shall be got approved from CWE before carrying out the wk. (iv) The independent testing of membrane for technical parameters given in particular specifications shall be carried out from Govt approved labs having fascilities for testing of membrane. (v) The guarnatee of treatment shall be for min 10 yrs reckoned from date of completion of whole wk.
43M&L for heat resistance tiles of size 300x300x10mm thick on roof slab of any colour approved over and including 15mm thick screed bed in CM (1:4) technical specification of roof tiles shall be as per IS 4457:2007 complete all as specified and directed by Engineer - in -Charge. Make: Johnson Endura , Kajaria, Orient
44M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment as in floor complete all as specified and directed by Engineer-in-charge
45M&L sand cushioning 25mm thick laying in floor finished even and fair to receive tile complete all as specified and directed by Engineer-in-charge
46M&L for 75 mm thick PCC (1:4:8), type D-2 (using 40mm graded crushed stone aggregate) as in sub base of floor finished even and fair complete all as spd & directed by Engr-in-Charge.
47M&L PCC (1;2:4) type B-1 using 20mm graded stone agregete as in sides of rounded or chamfered on edges of interlocking tiles complete all as spd & directed by Engr-in-Charge.
48M&L forproviding precast cement concrete(1:2:4) type B-1 with 20 mm graded aggregate for kerb stone and similar works with plain fair finishes including chamfers, weatherings, throat- ing etc. and setting in cement mortar (1:4) complete with joints to match complete all as specified and directed by Engineer-in-charge
49Supply, Installation and setup of Application server and backup server Dell PowerEdge Tower Server T550. The sever would be suitable for 5000 meters. The below specifications are indicative. The servers may be hosted at the locations provided by the department. • 3.5" Chassis with up to 8 Hard Drives (SAS/SATA), 1 CPU • CPUIntel® Xeon® Silver 4314 2.4G, 16C/32T, 10.4GT/s, 24M Cache, Turbo, HT (135W) DDR4-2666 • Memory -16GB RDIMM, 3200MT/s, Dual Rank • Hard Drive - 800GB SSD SAS ISE mixed use 12Gbps 512 2.5in HP AG Drive,3.5in HYB CARR, 3 DWPD • Standard Heat Sink for Less = 150W • Dual, Hot Plug, Non-Redundant Power Supply (2+0), 600W, Mixed Mode Make: Dell, HP, IBM Note: (1) The server cost would include two year charges for high speed 1 GBPS broadband connectionfor one locations. (2) the server cost would include suitable data switch,firewall,monitor.
50Supply and Installation of UPS for the server with the specification10 kVA, 230V suitable for INDIA Harsh Environment or Equivalent complete with joints to match complete all as specified and directed by Engineer-in-charge Make: APS, Emerson, Luminous
51Provision of high speed 1 GBPS broad bandfor the server after two years of defect liability period complete with joints to match complete all as specified and directed by Engineer-in-charge
52S & F Inverter along with tubular batteries having following specifications complete all as specified and directed by Engr-in-Charge:- (a) Capacity of 2KVA of inverter 1680 W, sine wave output. (b) Battery of 12 Volts, 150Ah tubular plates technology-2 Nos (c) High durability with sealed plastic housing (d) Comprehensive protection against short-circuit, reverse polarity, battery over charge, deep discharge etc. (e) Battery warranty of minimum 36 months (f) Intuitive display to easily understand staus of mains availability, battery status, etc. Make :Luminous , Model No : Cruze 2KVA, Battery-ILTT 18048N 150AH or techno-commercially or equivalent
53Supply and install hi wall split Air Conditioner (1.5 Tonn AC Capacity) units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 including timer arrangement of both AC complete all as specified and directed by engineer in charge
54S & F desktop computer with the following specifications complete all as specified and directed by Engr-inCharge :- Software Parameters:- (a)8GB RAM, DDR4 RAM with Genuine Windows 10 Operating system or higher version (b)Intel Processer with 8th Gen core i7 processor with min speed of 1.3 GHz (c)Hardware storage of min 1TB Hardware Parameters:- (a)Screen size of min 15 inches of black in color with full HD display (1920 x 1080), LED backlit display (b) Minimum of 3 USB ports. (c) With one Qwerty keyboard & wireless mouse. (d)UPS of min. 1kVA for backup Make : Dell, Model No : Optiplex 5060MT or commercially or equivalent in HP/Apple
55Supply , installation , testing and commisioning of wireless laserjet b&w printer for print, scan and copy with 40 page per minute capacity for 1200X1200 DPI as reuired and specified suitable for A4 size papers complete all as specified and directed by Engr-in-Charge Make: HP, Canon, Epson
56M & Lfor concealedconduit point wiring complete for light/ fan on independent /combine boardwith cable 1.5 sqmm (Nominal area) FRLSH PVC insulated multistranded unsheathed copper conductor,drawn in and includingPVC Concealed conduitpipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , aftercutting in wall chasing for conduits and sinking"s for modular metal flush boxes suitable length, Min 1.6 mmthickness and 50 mm depth for mounting, switches, sockets,fan regulatorwith modular cover plate with frame and making the gooddisturbed surfaces of wallin CM 1:3 with white wash or existing colour including provision ofcontinuousearth continuity conductoralong with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switchand connected to commonearth dolly, complete all as specified anddirecedby the Engineer in charge.
57All as per item No 56 above but socket 5 pin 5 Amp 230 volt flush type onsame board
58All as per item No 56here in before but for one socket outlet 5 pin , 5 Amp on independent board.
59Allas per item No 56 here in before but for one socket outlet 6 pin, 15 Amp with 2.5 Sqmm PVC copper conductor and 2.5 sq mm PVC insulated copper conductor as earth continuity conductor .
60All as per item No 56 here in before but for industrial socket metal clad plug and socket with MCBs single pole 20 Amp with 4.0 sqmm PVC copper conductor and 4.0 Sqmm PVC insulated copper conductor as earth continuity conductor.
61S & F modular switch5/6 Amps single pole one way,one module complete all as specified and directed by Engineer - in -Charge.
62S & F modular switch socket combination 5 pin, type 5/6 Amps5 in 1flush type complete all as specified and directed by Engineer - in -Charge.
63S & F modular switch socket combination 6 Pin, 5/16 Amps flush type complete all as specified and directed by Engineer - in -Charge.
64S & F modular socket outlet 5 pin 5 Amps flush type complete all as specified and directed by Engineer - in -Charge.
65Supply and fix industrial socket metal clad plug and socket with MCBs single pole 20 Amp complteall as specified and directed by Engineer - in -Charge.
66S & F modular stepped type, fan regulator not less than 120 watt for ceiling fan 1200/1400mm sweep complete all as specified and directed by Engineer - in -Charge
67S & F ceiling rose surface bakelitethree terminals complete all as specified and directed by Engineer - in -Charge.
68S & FTube light fitting withLED batten with aliminium housing andintegrated electronic driver,20 watt having input voltage AC90-300V, 50 Hz , 6500K, and all other accessories including connection with flexiblecable copper conductortwin coreof size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in -Charge.
69S&Fsecurity light fitting LED type 25 watt with all necessary acessories, Clear transparent acrylic cover, prewire suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in -Charge
70S & F Water tight bulk head fitting,comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,glass well,and including 10 watt LED lamp all as specified and directed by Engineer - in -Charge
71S & Fangle holder insulated body with back plate for conduit fittings complete all as specified and directed by Engineer - in -Charge
72S&F LED lamp 9W for angle holder complete all as specified and directed by Engineer - in -Charge.
73S & FMCB ‘B’ series type suitable for 240 volts, AC supply 40 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in -Charge.
74S & FMCB ‘B’ series type suitable for 240 volts, AC supply06 to 32 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KAcomplete all as specified and directed by Engineer - in -Charge.
75S&FMCCB TPN 63 Amps with breaking capcity 16kA ,Fixed TM and 415 volts AC Supply ISI markedcomplete all as specified and directed by Engineer - in -Charge. .
76S&F sheet metal enclosure double door 8 way SPN 230V ISI marked IP 43 complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made complete all as specified and directed by Engineer - in -Charge.
77S&FSheet metal enclosure for double door Vertical DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounting VTPN 4 Way 415 VoltISI marked 250Amps busbar stove enameled dust and vermin proof,IP:43 protection suitable for incorporation FP MCCB(V-Tech) N1 Frame upto 125A,Isolators and including give connection with wire and cable etc complete all as specified and directed by Engineer - in -Charge.
78Supply and hanging/fixing ceiling fan 1200 mm sweep, AC supply (Input voltage range- 120 to 280 V) , BLDC type,5 star rated, BEE and ISI marked super enamelled,copper winding of "B" class insulation,single phase minimum 26 W (± 10 %) Temperature rise 40 degree maximum without remote with and including operative based capacitive regulator, 03 Nos blade, down rod including accessories,white colour, total harmonic less than 10 % . 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified and directed by Engineer - in -Charge. Note :Serial nos as issued by Engineer-In-Charge of ceiling fan and GE office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for sameshall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. MAKE: Orient electric 1200mm hector 500/ Havells effeciencia neo 1200mm/ Cromption Energion HS.
79S & Fsub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLSH stranded copper conductor drawn in and including concealedPVC conduict dia 20mm “medium quality” conduit including 6.00 Sq mm (Nominal Area) copper cableas earthcontinuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and coversincluding necessary connections, PVCflexible pipes are used in panel board while connecting the cablecomplete all as specified and directed by Engineer - in -Charge. Note : (i) PVC cable and PVC conduit shall be ISI marked. (ii) Two run of 6 Sqmm cable , one run of 6 Sqmm earth wire and pvc conduit and its accessories shall be measured and paid as one length .
80M & L Rigid non-metallic PVC conduit 20 mm exclusive of boxes (junction/terminal) but inclusiveof all tees,bends,elbows,reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.complete all as specified and directed by Engineer - in -Charge.
81Supply and lay jointing and testing and commissioningof50 Sqmm x 3.5 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer in charge.
82M & L for sand cushioning with dry and clean locally available sand for underground cable 8cm before laying cable and 15 cm after laying cable and punned to 18 cm after laying of cable complete all as specified and directed by Engineer-in-Charge Note: Pressed thickness shall be considered for payment purpose
83Supply and lay standard size bricks subclass B typecomplete all as specified and directed by engineer in charge.
84Supply and fixingGI pipe 50 mm dia light grade for cable protection in walls /trenches or any situation including clamp nut bolt etc complete all as specified and directed by Engineer-in-Charge.
85M & L for Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mmthick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of plate not less than 1.5 Mtr below ground level , connecting to GI earth lead 4 mm dia GI earth wire ,by means of bolts,nuts and washers of GIand protection by provisionof GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20 mm grade stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 25mmX25mmX6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape ,GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40 mmX 8 mm FI with fixing arrangement ,funnel, wire mesh and earth work in hard dense soil ,returning filling in and removal of surplus soil to a distance not exceeding50 mtrs all as per electric plate no.3 of SSR part 1 and connecting to earth test point completeall as specified or indicated including testing on completion all as specified and directed by Engr -In - Charge
86Supply and Installation of Smart Single Phase Meter with the following specifications: • AC Single Phase two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10A-60A conforming to IS-16444 and relevant IEC standards with inbuilt 865-867 MHz Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamperfeatures, Microprocessor and LCD based circuitry.. • Meter Should support the following data : 30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, 30 load survey data for energy, monthly billing survey for Cumulative Energy and Max Demand • Meter should have connect / disconnect functionality operable from prepaid billing software Electric supply will be disconnected under followingcondition.(a)Over Current (105 % of Max current in any phase (b) Load control limit (Programmable) (c) Disconnection signal from utility control centre (d) The meter shall confirms requirements specified in IS-15959. (e) All meters should be connected/ Integrated with their respective Data control units and approved softwares/ servers. • The meter should support open communication protocol DLMSwith the software MAKE: Secure, L&T, HPL,Elmeasure Note: (a) The contractor would be responsible from removing the existing meter, noting down the reading and depositing it with the MES.
87(b) It would be possible to run the meter in both prepaid and postpaid mode (c) The meters to carry 05 year guarantee. The contractorshall furnish 05 (Five) years replacement guarantee for prepaid meters installed under this contract except damage from water and fire. (d) Whole work shall be executed through Origional Equipment Manufacturer (OEM) or its authorised repersentative. (e) Contractor will submit necessary MoU on Rs 100 stamp paper with OEM/Authorized rep (Who will provide all these facility mentioned above before commencement of work) (f)The contractor should maintain reserve stock of 3% of total meter installed and replace the faulty meter within one week of complaint given to him.Otherwise penal recovery of Rs 100/day/meter will be recovered from the contractor. (g) Meter should be compliant to IS16444. Data exchange protocol used should be as per IS 15959 (2011).(h) Meter manufacturer should share LLS Key & HLS Key of each meter. (j)Thesmart meter should be RF enabled, the buyer has to insist during purchase (in specs) that their MDAS can be exchanged with other third- party billing systems, and that they will provide support to enable data exchange. Another point to be confirmed from meter manufacturing module used inside the meter is a plugin module. (k) The Cost of making good disturbed surface & matching with existing surfaces is deemed to included in quated rate. (l) While installing power shutdown etc needs to be take in consulation with the user and MES .The contractor should ensure Minimum disturbance of Powerwhile changing the old Metering system to New Meters
88Supply and installation of polycarbonate boxes for the single phase smart meters as required including wiring complete all as specified and directed by engineer-in-charge.
89Supply and Installation of IP-67 protection Data Concentrator Units (DCU) compatible for remote Automatic Metering Infrastructure (AMI) solution and capable of communicating with the smart energy Meter in the corresponding frequency band and with the data server through GPRS/Ethernet. It would have internal memory to store data of at least 200 modules. It would have inbuilt battery back-up. It would have IP-67 protection. It would support auto discovery of the meters and self healing mechanism for the breaks in the RF network complete all as specified and directed by engineer-in-charge. Make: Secure, L&T, Schneider, CyanConnode
90Supply and Configuration of the Web based Software with following modules: (i) Meter Data Management Module The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system.The meter data management system would capture and provide the following data: (a) 15/30 min instantaneous data from all the meters for seven parameters (phase wise as applicable)– Cumulative Energy, Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency (b) Monthly billing survey data for cum energy and max demand (ii) Postpaid /Prepaid Billing Module The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data / billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required.
91(iii) Occupation and Vacation Module The system would support occupation / vacation and billing reports. the software would be collecting data from DCU. The software would provide access to staff as well as the occupant for the data. (iv) Web site: There would be a dedicated website for the AGE and BSO team to view all the data and information. The designated users in MES would have the admin access to the application. The MES staff would also have the access of the key information on an android mobiles app (for admin use). website must have only access ofMES authority, not to any third party or web devloper and OEM team will visit regularly or on request for any bug fixing as required for smooth runnung of website and application software. (v) Customer Portal The system would include a customer portal for the resident /occupant to log in and view their own energy / billing data. There would be android and iOS mobile apps for the user to monitor its own data and balance on regular basis. (vi) Energy Accounting Module The system would include features of energy accounting. The system would be able to account for total energy block wise, facility wise and would also allow calculations of unaccounted energy in case total energy meter is also available. (vii) Communication Module The system would provide communication of energy data and bills via print, email and sms methods. (viii) Meter Master Data The system would support meter master data repository. The system would support meter replacement process. (ix) Excel Export The system would support export of metering and billing data in excel format.
92(x)Customer Care Module - The software would include a customer care module where the user would be log in any complaints. The service provider would monitor the complaints and carry out the necessary activities for the complaints resolution. (xi) Meter Installation Module - The software would include an app based meter installation module where the meter installation or changes can be captured on the app itself and the readings may be demonstrated to the user if required on the app itself. (xii) Activities Communication - The software support communication of the various activities such as occupation, vacation, meter change. personal detail change etc. with the user as well as the department on email.contractor should submitMoUfrom OEM toprovide the software & hardware update for smart meter / Data communicator/ website / Mobile app /application software. (xiii) (a). Application software / Mobileapp,website and other connected items must be supplied as recommonded byOEM (Manufacturar of meter) irrespective of developers and contractor should have submit MOUon 100 rupees non judicial stamp paperto provide the availability ofsoftware update / hardware spares for five years. (b) all softwares / applications must have security provisions to protect privacy data and army area security, (c) The software would contain two year defect liability including all operating expenses such as GPRS charges, hosting charges etc. (d ) Personal data of user and electric comsumption data should be stored on MES computer/ server designated specifically for the purpose or MEITY (Ministry of Information Technology) approved GCC (Government Community Cloud).
93(e)Personal data for user/ qtr/ accn on standard format as required for software shall be provided by the dept. (f)The configuration of smart meter will be through software which will be compatible with all makes of smart meter and software will be audited by CERT-INDIA empaneled firm and cost of audit is to be borne by contractor. (g) The software provided by the firm is to be user friendly and compatible with future upgradation. (h)System should be compatible with all possible payment/recharge mode, be it online or offline mode. (j) Software for smart meter should also include prepayment mode recovery of licence fee, higher charge of furniture, water charges etc as directed to contractor by MES. (k) Smart meter and software/mobile application will be in compliance withservice HQ cyber security norms. (l) One payment gateway would be installed and connected to the SBI publicbank account provided by the GE. This payment gateway should have both payment options of online payment and offline payments. Make: Innologix, Schneider, Oracle Note: (a) The software would be either on hosted on MEITY (Ministry of Information Technology) approved GCC (Government Community Cloud) or on MES provided server.
94(b) The software would contain two year defect liability including all operating expenses such as GPRS charges, hosting charges etc. (c) The software can be scaled up to integrated with any IS16444 based meter provided the meter inetgration details and/ or headend integration details are made available.
95One year comprehensive maintenance including operating costs after completion of work. They would include the following items: (a) Monthly sim charges for the DCU. The contractor would ensure supply of appropriate SIMs/modules to ensure necessary signal availability. The contractor would change the sim or sim provider as required. In case of network issues, the contractor would liaison with the telecom service providers for necessary resolution. (b) Recurring SMS charges. The SMS would be issued for the payments alerts, low balance alerts and disconnection / connection alerts. (c) Software AMC. This would include necessary upgradations in the software such as support to the chrome browser changes, android version changes , iOS version changes. These changes happen on frequent basis and the software would support all the changes. (d) Changes in the government tariff structure. The government tariff structure changes may require software upgrade. The same would be included in the AMC scope of work. (e) Remote server admin support - Ensuring adequate database back up, upgradations in the operating system, anti virus updates, database upgrade etc. (f) Reports Development - The additional reports as needed for the success of the project would be developed (g) Software installation on any alternate / backup server if required
96Contd....... (h) The communication network monitoring and support (i) Configuration of the repaired / replaced hardware in the system (j) Trouble shooting and necessary actions to run the system as required. (k) Software bug fixing as and when required (l)Contractor will employ Min 01Nos Trained/Skilled Personel At GE SGNR in Shift from 9:00 AM to 5:00 PM (Except on Sunday and Holiday) After completion of work for a period of one year, The Duties shall include:- (i) Managing meter recharge problems.(ii) Rectifying any problem that may occur in the hardware as well as software system and coordinating for smooth functioning of the same. (iii) Deploying all measures for corrective actions as and when required. (iv) Acting as a link between Respective GE/Resident and the parent company providing the metering system. (v) Providing training to MES personnel as and when required & directed. (vi)Generation and Maintenance ofE-cash payment details and updating the same to MES designated officer. (vii) Providing any other associated technical support. NOTE:- (a) This item shall be operative & commence after declaring all meters commissioned. (b) Only Cashless payment i.e. through debit/credit cards will be acceptable.
97S & Fin replacement sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLSH stranded copper conductor drawn in and including concealedPVC conduict dia 20mm “medium quality” conduit including 6.00 Sq mm (Nominal Area) copper cableas earthcontinuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and coversincluding necessary connections, PVCflexible pipes are used in panel board while connecting the cablecomplete all as specified and directed by Engineer - in -Charge. Note : (i) PVC cable and PVC conduit shall be ISI marked. (ii) Two run of 6 Sqmm cable , one run of 6 Sqmm earth wire and pvc conduit and its accessories shall be measured and paid as one length
98Supply and Installation ofSmart Three Phase Meter with the following specifications: (a) AC Three Phase Four Wire, Tamper Proof, Static Meter of Class 1.0, 415 V, 50 Hz, 10 A-100 A ISI marked conforming to IS-16444 2015(reaffirmed 2020) and relevant IEC standards with inbuilt 865-867 MHz Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry. (b)Meter Should support the following data : 30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, 30 load survey data for energy, monthly billing survey for Cumulative Energy and Max Demand (c)Meter should have connect / disconnect functionality operable from prepaid billing software Electric supply will be disconnected under followingcondition.(a)Over Current (105 % of Max current in any phase (b) Load control limit (Programmable) (c) Disconnection signal from utility control centre (d) The meter shall confirms requirements specified in IS-15959. (e) All meters should be connected/ Integrated with their respective Data control units and approved softwares/ servers. (d) The meter should support open communication protocol DLMSwith the software MAKE: Secure, L&T, HPL Note: (a) The contractor would be responsible from removing the existing meter, noting down the reading and depositing it with the MES. (b) It would be possible to run the meter in both prepaid and postpaid mode (c) The meters to carry 05 year guarantee. The contractorshall furnish 05 (Five) years replacement guarantee for prepaid meters installed under this contract except damage from water and fire.
99(d) Whole work shall be executed through Origional Equipment Manufacturer (OEM) or its authorised repersentative. (e) Contractor will submit necessary MoU on Rs 100 stamp paper with OEM/Authorized rep (Who will provide all these facility mentioned above before commencement of work) (f)The contractor should maintain reserve stock of 3% of total meter installed and replace the faulty meter within one week of complaint given to him.Otherwise penal recovery of Rs 100/day/meter will be recovered from the contractor.(g) Meter should be compliant to IS16444. Data exchange protocol used should be as per IS 15959 (2011). (h) Meter manufacturer should share LLS Key & HLS Key of each meter. (j)Thesmart meter should be RF enabled, the buyer has to insist during purchase (in specs) that their MDAS can be exchanged with other third- party billing systems, and that they will provide support to enable data exchange. Another point to be confirmed from meter manufacturing module used inside the meter is a plugin module. (k) The Cost of making good disturbed surface & matching with existing surfaces is deemed to included in quated rate. (l) While installing power shutdown etc needs to be take in consulation with the user and MES .The contractor should ensure Minimum disturbance of Powerwhile changing the old Metering system to New Meters
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail