Military Engineer Services-MES has published Tender For Periodical Preventive And Comprehensive Maintenance Of Dg Sets, Amf Panel, Ups System And Battery Bank In The Area Of Age E/M-I (Af) Palam Under Ge (Af) Palam Delhi Cantt-10. Submission Date for this Tender is 19-06-2023. UPS Tenders in palam Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

37798237
Corrigendum : Tender For Periodical Preventive And Comprehensive Maintenance Of Dg Sets, Amf Panel, Ups System And Battery Bank In The Area Of Age E/M-I (Af) Palam Under Ge (Af) Palam Delhi Cantt-10
Open Tender
Indian
Delhi
palam
19-06-2023

Tender Details

Periodical Preventive And Comprehensive Maintenance Of Dg Sets, Amf Panel, Ups System And Battery Bank In The Area Of Age E/M-I (Af) Palam Under Ge (Af) Palam Delhi Cantt-10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

Name of Work: PERIODICAL PREVENTIVE AND COMPREHENSIVE MAINTENANCE OF DG SETS, AMF PANEL, UPS SYSTEM AND BATTERY BANK IN THE AREA OF AGE E/M-I (AF) PALAM UNDER GE (AF) PALAM DELHI CANTT-10
Sl. No. Item Description
1Material and Labour for Quarterly Periodical, preventive and comprehensive maintenance of different capacity DG sets (100 KVA to 125 KVA) installed in various locationsat AF Stn Palam consisting of the following :- (a) Checking of total system for proper functioning. (b) Checking of Engine Oil, Fan Belts, Hose Pipes, Fuel pipes and Filters. (c) Checking of Foundation Bolts, Ante-vibration Pads, Oil and Water Safety devises. (d) Cleaning of fuel tank, checking of distilled water in batteries, checking of coolent concentrate andpetrollium jelly on battery terminals. (e) Checking of batery charging system, RPM of DG set, Volt meter, Ammeter etc for their proper functioning.
2All as per item No.1 here-in-before but of capacity 25 KVA to 75 KVA.
3All as per item No.1 here-in-before but of capacity 160 KVA to 250 KVA.
4All as per item No.1 here-in-before but of capacity 500 KVA to 600 KVA (NOTE for item No 1 to 4 : Each job shall be measured and paid separately for each Generator Set)
5S&F in replacement of"B" Check kit comprissing of Diesel filters, lubricant oil filter set complete with gasket for DG sets for 600 KVA, Make : Kirloskar.
6S&F in replacement of"B" Check kit comprissing of Diesel filters, lubricant oil filter set complete with gasket for DG sets for 400/500 KVA, Make : Kirloskar.
7S&F in replacement of"B" Check kit comprissing of Diesel filters, lubricant oil filter set complete with gasket for DG sets for 62.5/75 KVA, Make : Kirloskar.
8S&F in replacement of"B" Check kit comprissing of Diesel filters, lubricant oil filter set complete with gasket for DG sets for 180/200 KVA, Make : Kirloskar.
9S&F in replacement of"B" Check kit comprissing of Diesel filters, lubricant oil filter set complete with gasket for DG sets for 160 KVA, Make : Kirloskar.
10S&F in replacement of"B" Check kit comprissing of Diesel filters, lubricant oil filter set complete with gasket for DG sets for 100/125 KVA, Make : Kirloskar.
11S&F in replacement of"B" Check kit comprissing of Diesel filters, lubricant oil filter set complete with gasket for DG sets for 25/30 KVA, Make : Kirloskar.
12S&F in replacement of element air cleaner ofDG sets 600 KVA, Make of DG set : Kirloskar.
13S&F in replacement of element air cleanerofDG sets 400/500 KVA, Make of DG set : Kirloskar.
14S&F in replacement ofelement air cleaner ofDG sets 62.5/75 KVA, Make of DG set : Kirloskar.
15S&F in replacement of element air cleanerofDG sets 180/200 KVA, Make of DG set : Kirloskar.
16S&F in replacement ofelement air cleanerofDG sets160 KVA, Make of DG set : Kirloskar.
17S&F in replacement ofelement air cleanerofDG sets 100/125 KVA, Make of DG set : Kirloskar.
18S&F in replacement ofelement air cleanerofDG sets 25 KVA, Make of DG set : Kirloskar.
19S&F in replacement of water hose pipe set for DG sets 500 to 600 KVA, Make : Kirloskar/Cummins
20S&F in replacement of water hose pipe set for DG sets 180 KVA, Make : Kirloskar/Cummins
21S&F in replacement of water hose pipe set for DG sets100 to 200KVA Cummins/Kirloskar
22S&F in replacement of fuel pipe line set for DG sets 500 to 630 KVA, Make : Kirloskar/Cummins
23S&F in replacement of fuel pipe line set for DG sets 100 to 200 KVA, Make : Ruston/Cummins/Kirloskar
24S&F in replacement of solenied shut off valve 100 to 200 KVA as per model, Make : Cummins/Kirloskar
25M & L for overhauling and calibration offuel injection pumpincluding setting the tapped and replacement of seal if required excluding gear pump suitable for DG set ofCapacity 500 KVA & 600 KVA, Make : Kirloskar/ Cummins
26All as per item No.25 here-in-before but DG Set of Capacity 180 KVA to 200 KVA Make of DG set: Kirlosker/ cummins
27All as per item No.25 here-in-before but DG Set of Capacity 100 to 125 KVAMake of DG set : Kirloskar/ Cummins
28All as per item No.25 here-in-before but DG Set of Capacity 62.5 to 75 KVAMake of DG set : Kirloskar/ Cummins
29S&F in replacement of radiator fan belt set for DG sets500/600 KVA Make of DG set : Cummins/Kirloskar
30S&F in replacement of radiator fan belt set for DG sets100 to 200 KVA Make of DG set: Ruston/Cummins/Kirloskar
31S&F in replacement ofwater safty device for DG sets 200 to 500 KVA, Make of DG set : Kirloskar/Cummins
32S&F in replacement of water safty device for DG sets100 to 200 KVA Make of DG set : Ruston/Cummins/Kirloskar
33S&F in replacement ofoil safty device for DG sets 200 to 500 KVA, Make of DG set : Kirloskar/Cummins
34S&F in replacement ofoil safty device for DG sets100 to 200 KVA Make of DG set : Ruston/Cummins/Kirloskar
35S&F in replacement ofhead gasket for DG sets 250 to 500 KVA, Make of DG set : Kirloskar/Cummins
36S&F in replacement of head gasketfor DG sets100 to 200 KVA Make of DG set : Ruston/Cummins/Kirloskar
37S&F in replacement of tapet cover gasket for DG sets 250 to 500 KVA, Make of DG set : Kirloskar/Cummins
38S&F in replacement of tapet cover gasket device for DG sets100 to 200 KVA Make of DG set : Ruston/Cummins/Kirloskar
39S&F in replacement of fresh water pump with clamp & nut for DG sets 180 to 200 KVA,
40Taking down Radiator assembly from DG set, cleaning includingbrazing of water tubes if found leakage during cleaning. The radiator shall be cleaned thoroughly and remove scale deposits by suitable cleaning material. The radiator shall be tested for leakage by means of injecting pressure. The complete DG set housing/ block shall also be de-carbonized/cleaned by means of suitable cleaning material and re-fixing the same and testing after completion for DG Set of Capacity 400 KVA/500 KVA all as specified and directed by Engineer-in-Charge
41All as per item No.40 here-in-before but DG Set of Capacity 180 to 160 KVA
42S&F in replacement of gear pump of FIP pump for DG set 200 to 400 KVA, Make : Kirloskar.
43All as per item No. 42 here-in-before but DG Set of Capacity 160/125 KVA Make:-Cummins.
44Taking out the unserviceableself starter (24 volts) for repair and overhauling the same with replacement of carbon brush, carbon brush holder, pinion, G M. bush, armature taping, winding. varnishing and heating the field coil, greasing the bearing.Re-assembling the self starter, refixing in engine including replacement of starting switch and repairing to panel board wiring and testing complete.
45All as per item No 44 here-in-before but for 12 Volt.
46M&L for repair to battery charger of 12/24 volts capacity complete by replacingthe defective parts such as diode,rectifier including repair to dimmer complete.
47S&F in replacement of Printed Circuit Board Card (EC-2 Relay Card) in existing DG set AMF panel board. Make: Kirlosker/Micronems/Verdic electronic
48S&F in replacement of battery connection wire for 12V, battery copper conduct for PVC insulated multi strand 1.25 m long duly fixed with terminals and lugs (440/014 or equivalent to 95 sqmm).
49S&F in replacement of water/ oil temperature gauge suitable for existing DG Set complete.
50M & L for calibration & overhauling of Injector with replacement of spring, ball check, retainer, link injector, pin spiral, cup injector, barrel & plunger etc of kit injector repair and testing on full load complete.
51M&L for disconnecting the alternator from DG Set of 200/250 KVAfor rewinding of armature bring to civil worshop,cutting and removing burnt copper wire including insulating material ,cleaning & removing corbon (smoke) particals .Rewinding the armature with good quilty of insulated copper wire of same wieght & size of existing wire, jointing,varnshing,and heating , re-assembling and taking back at site refitting &reconnecting complete testing on full load (Note : winding wire and paper mica shall be measured and paid seperately)
52All as per item No 51 but DG set 125/100 KVA Capacity.
53Supply only Super Enamel Copper Winding Wire 16 to 20 Gauge as approved/ordered for repair /re-winding of alternator complete.
54S&F in replacement ofCotton Tape Off Sizes, as approved/ ordered for repair/re-winding of alternator, and varnicing,baking and heating the winding to achieve required omhmic value complete.
55S&F in replacement of terminal block for alternator 200 to 500 KVA capacity complete.
56M&L for dismantling the engine of DG Set capacity125to200 KVAfor checking and repair work by opening complete engine head, piston, cylinder and FIP unit including Remove cylinder head covers. & Check valve clearance between rocker arms and valve stem end with filler gauge as per the valve setting sequence. 0.3mm for inlet valve and 0.5mm for exhaust valve, re-assembling the existing parts complete testing on full load all as specified and as directed by Engr-in-charge.(Note : Items required to make the DG Set serviceable shall be measured and paid seperatively under relevant items of the schedule).
57Supply only in replacement of kit Engine Piston
58Supply only in replacement of piston Liner kit
59Supply only in replacement of Starter 12V DC complete
60Supply only in replacement of Oil seal rear
61Supply only in replacement of Oil Seal front
62Supply only in replacement of Bearing trrust
63Supply only in replacement of Sleeve Injector
64Supply only in replacement of Valve Inlet
65Supply only in replacement of Valve Exhaust
66Supply only in replacement of STARTER RING 121 TEETH, 3.175 MODULE
67Supply only in replacement of Valve seat
68Supply only in replacement of Ring liner seal
69Supply only in replacement of Gear wheel complete
70Supply only in replacement of Gasket Set, head gaskets, body gasket complete
71S&F in replacement of maintenance freebattery 12 volt 180 AHcomplete as directed by Engr-in-Charge. Make:- Exide/Amron/Sucam
72S&F in replacement of maintenance freebattery 12 volt 100 AHcomplete as directed by Engr-in-Charge. Make:- Exide/Amron/Sucam
73S&F in repalcement of automatic voltage regulator for 500/380/250/185/125 KVA DG sets including testing and commissioning etc complete. Make: National/Atlex electric
74S&F in replacement of fuel level sensor which senses level of fuel in fuel tank and communicates engine safety unit to provide alarm or stopping of DG as per designed operating levels of fuel complete.
75S&F in replacement of electronic battery charger in put voltage 230 V Ac and out put voltage 12/24 volt DC fixed in AMF panel of DG set complete. Make: Teknika/ Electro expert/ Active control
76S & F in replacement of exhaust silencer complete with muffler of 200 KVA DG set complete connects engine and DG silencer to drive away hot gases generated during operation of DG to atmosphere through silencer complete.
77Supply and replacement / topping up engine oil multi grade 15W/40 Make : Indian Oil/HP/Castrol.
78Supply and filling coolent concentrate for DG set all as specified and directed by Engr-in-charge.
79Supply and filling distilled waterfor DG Set batteryall as specified.
80M&L for painting to DG sets 250 to 500KVA capacity with two coats of synthetic enamel paintwith spray gun after preparation of surface including scraping, cleaning and washing of engine alternator, base frame, control panel and fuel tank of approved coloured complete and writing SM No and capacity etc all as directed at site.
81All as per item No. 80 but 100 to 200KVA capacity DG sets.
82All as per item No. 80 but 25 KVA to 63 KVA capacity DG sets.
83M&L for checking the control panel of 3 phase UPSof capacity 30/50 KVA by opening the cabinat and checking the faulty circuit / hardware/ micro processor relay and PCB circuit including cleaning, removing the dust particle by using high speed blower and calibrating & testingthe relays for constant out put voltage complete.
84M&L for checking the control panel of 3 phase UPSof capacity 10/20 KVA by opening the cabinat and checking the faulty circuit / hardware/ micro processor relay and PCB circuit including cleaning, removing the dust particle by using high speed blower and calibrating & testingthe relays for constant out put voltage complete.
85M&L for checking the control panel of 3 phase UPSof capacity upto 5 KVA by opening the cabinat and checking the faulty circuit / hardware/ micro processor relay and PCB circuit including cleaning, removing the dust particle by using high speed blower and calibrating & testingthe relays for constant out put voltage complete.(Note for item No 83 to 85: Servicing work to be carried out reputedService Engineer/ Company of manufacturer of DG set and spares wiil be measured & paid seperately).
86Supply only in replacment of UPS LM relayfor 10/ 20 KVA UPS Make : Sucam/APC/Sintrac
87Supply only in replacment of UPS LM relayfor upto 20 KVA UPS Make : Sucam/APC/Sintrac
88Supply only in replacment of Capacitance 4/6 mfd.
89Supply only in replacment of Hardware assembly as per existing make and model for 10/ 20 KVA UPSMake: Sucam/ Sinetrac / APC
90Supply only in replacment of Hardware assembly as per exting make and model for upto 5 KVA UPSMake: Sucam/ Sinetrac / APC
91S&F in replacement of power contactor 3 pole with AC coil 415V, 50 Hz of capacity 32 Amps as per existing NO/NCcomplete Make : L&T/Havells/Schnieder.
92S&F in replacement of power contactor 3 pole with AC coil 415V, 50 Hz of capacity 40 Amps as per NO/NC complete Make : L&T/Havells/Schnieder.
93S&F in replacement of power contactor 4 pole with AC coil 415V, 50 Hz of capacity 150- 185 Amps as per existing NO/NCcomplete Make : L&T/Havells/Schnieder.
94S&F in replacement of power contactor 4 pole with AC coil 415V, 50 Hz of capacity 250 Amps as per NO/NC complete Make : L&T/Havells/Schnieder
95S&F in replacement of power contactor 4 pole with AC coil 415V, 50 Hz of capacity 63 to75 Amps range as per NO/NC complete Make : L&T/Havells/Schnieder
96S&F in replacement of sealed maintenance free fully charged Nickle cadmium battery 65Ah, 12 volts complete. Make: Sucam/ EXIDE/Amron
97S&F in replacement of sealed maintenance free fully charged Nickle cadmium battery 42Ah, 12 volts complete. Make: Sucam/ EXIDE/Amron
98S&F in repair copper wire 50 Sqmm fixed on wall by saddles to connect with earth to equipment complete.
99S&F in replacement of PCB relay for UPS 30/ 50 KVA as per existing modelincluding connecting to existing control circuit and testing complete
100M&L in replacement of PCB relay for UPS 10/20 KVA as per existing modelincluding connecting to existing control circuit and testing complete
101M&L in replacement of DPA type module 10 KVA for moudulor UPS as per existing modelincluding connecting to existing control circuit and testing complete
102M & L for checking the AMF panel of DG set calibrating the relays for auto / manual run of DG set and testing the circuit for auto run complete.
103M&L in replacement of over voltage relay for AMF panel of DG set of any capacity including connecting to existing control circuit complete. Make: Teknika/PIC
104M&L in replacement of under voltage relay for AMF panel of DG set any capacity including connecting to existing control circuit complete. Make: Teknika/PIC
105S&F in replacement of micro processer control panel for 100/125 KVA DG set by taking out unserviceable relay complete with following parameters : (Make of DG set : Kirlosker) (a)Individual phase current (Amps) (b) Phase voltages (V) (c ) Generator output frequency (Hz) (d) Engine water temperature (Deg.C) (e) Lube oil pressure (kpa) (f) Working hours (g) Push button (Starter) & (stop) (g) LED indications for main function