Tender For Repair/Replacement Of Various Capacity Lt Switch Gears, Mccbs, Acbs, Contactor, Apfc Panels, Security Light And Other Misc E/M Works At Af Stn Faridabad In Aor Of Ge(Af) Faridabad, faridabad-Haryana

Military Engineer Services-MES has published Tender For Repair/Replacement Of Various Capacity Lt Switch Gears, Mccbs, Acbs, Contactor, Apfc Panels, Security Light And Other Misc E/M Works At Af Stn Faridabad In Aor Of Ge(Af) Faridabad. Submission Date for this Tender is 23-06-2023. Gear Product Tenders in faridabad Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

37798185
Corrigendum : Tender For Repair/Replacement Of Various Capacity Lt Switch Gears, Mccbs, Acbs, Contactor, Apfc Panels, Security Light And Other Misc E/M Works At Af Stn Faridabad In Aor Of Ge(Af) Faridabad
Open Tender
Indian
Haryana
faridabad
23-06-2023

Tender Details

Repair/Replacement Of Various Repair/Replacement Of Various Capacity Lt Switch Gears, Mccbs, Acbs, Contactor, Apfc Panels, Security Light And Other Misc E/M Works At Af Stn Faridabad In Aor Of Ge(Af) Faridabad

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-Jun-2023 Date Date 16-06-2023
2 02-Jun-2023 Tender Documents Terms and Conditions 16-06-2023
3 02-Jun-2023 BOQ BOQ 16-06-2023
4 16-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 76000.0 /-
Tender Value
INR 38 Lakhs /-

BOQ Items

Name of Work: REPAIR/REPLACEMENT OF VARIOUS CAPACITY LT SWITCH GEARS, MCCBS, ACBS, CONTACTOR, APFC PANELS, SECURITY LIGHT AND OTHER MISC E/M WORKS AT AF STN FARIDABAD IN AOR OF GE(AF) FARIDABAD
Sl. No. Item Description
1Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr depth for laying of cables/poles or foundation etc and getting outcomplete all as specified and directed y Engineer-in-Charge.
2Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cmapart complete all as specified and directed y Engineer-in-Charge.
3Removing of surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed y Engineer-in-Charge.
4Material and labor for sand cushioning to XLPE cable with using clean dry and natural river sand with a layer of 8 cm thick before laying the cable and 15 cm thick layer after laying the cable and this then gently punned down to a thick of 10 cm above the top the upper most cable complete all as specified and directed y Engineer-in-Charge.
5Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm complete all as specified and directed y Engineer-in-Charge.
6Supply,Laying,Connecting and testing in repairs cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 185 Sqmm 3.5 core complete all as specified and directed y Engineer-in-Charge.
7All as above item No 6 But Size 95 sqmm 3.5 core complete all as specified and directed y Engineer-in-Charge.
8All as above item No 6 But Size 70 sqmm 3.5 core complete all as specified and directed y Engineer-in-Charge.
9All as above item No 6 But Size 35 sqmm 3.5 core complete all as specified and directed y Engineer-in-Charge.
10All as above item No 6 But Size 25 sqmm 4 core complete all as specified and directed y Engineer-in-Charge.
11All as above item No 6above But Size 16 sqmm 4 core complete all as specified and directed y Engineer-in-Charge.
12All as above item No 6above But Size 10 sqmm 4 core complete all as specified and directed y Engineer-in-Charge.
13Supply and Fix cable jointing kit,heat shrink type for 1100 volts grade,XLPE insulated armoured heavy duty electric cable with aluminium conductor,cross sectional area 6-16 Sqmm 4 core complete with jointing material and accessories including testing complete all as specified and directed y Engineer-in-Charge.
14All as above item No 13 but Size 25-35 sqmm 4 core complete all as specified and directed y Engineer-in-Charge.
15All as above item No 13 but Size 50-95 sqmm 3.5 core complete all as specified and directed y Engineer-in-Charge.
16All as above item No 13 but Size 120 - 185 qmm 3.5 core complete all as specified and directed y Engineer-in-Charge.
17S & F in repairs Earth test box made of powder coated, 3.15 mm thick, CRCA sheet,20 cm x 20 cm x 10 cm size conforming to CPRI approved and IP-65 protection class,right hinge openable type including mounting arrangement such as making hole in wall,providing MS clamp,nut,bolt etc complete manufactured through approved manufacturers complete all as specified and directed y Engineer-in-Charge.
18S&F in repairs MCCB 3 pole 415 volts fixed type 160 Amps with braking capacity 36KA after taking out old U/S one complete all as specified and directed y Engineer-in-Charge. Make : Havells/L&T/C&S
19S&FMCCB 3 pole 415 volts in repairs,fixed type 63 Amps to 100 Amps with braking capacity 16 KA.after taking out old U/S onecomplete all as specified and directed y Engineer-in-Charge. Make: Havells/L&T/C&S
20S&F in repairs MCCB 3 pole 415 volts fixed type 200Ampswith braking capacity 36KA after taking out old U/S one complete all as specified and directed y Engineer-in-Charge. Make : Havells/L&T/C&S
21S&F in repairs MCCB 3 pole 415 volts fixed type 250Ampswith braking capacity 36KA after taking out old U/S onecomplete all as specified and directed y Engineer-in-Charge. Make : Havells/L&T/C&S
22S&FMCCB 3 pole 415 volts in repairs,fixed type 32 Amps with braking capacity 16 KA.after taking out old U/S one.all as specified and directed.Make: Havells/L&T/C&S
23S&F in Repairs Contactor, (4 Pole AC & DC Control) operational current AC1,160 Amps,poles composition- 4NO,DC control ref-LP1D80004 of TC complete all as specified and directed y Engineer-in-Charge.
24S&F in Repairs Contactor, (4 Pole AC & DC Control) operational current AC1,125 Amps,poles composition- 4NO,DC control ref-LC1DT125A of TC complete all as specified and directed y Engineer-in-Charge.
25S&F MNX 18, 3 pole contractor,2 NO+ 2 NC,415 volts AC, confirms to IS/IEC 60947 -4-1, in existing model and make including after taking out old unserviceable one, complete all as specified and directed y Engineer-in-Charge.
26S&F MNX 95, 3 pole contractor,2 NO+ 2 NC,415 volts AC, confirms to IS/IEC 60947 -4-1, in existing model and make including after taking out old unserviceable one, complete all as specified and directed y Engineer-in-Charge.
27S&F MNX 70, 3 pole contractor,2 NO+ 2 NC,415 volts AC, confirms to IS/IEC 60947 -4-1, in existing model and make including after taking out old unserviceable one, complete all as specified and directed y Engineer-in-Charge.
28S&F MN contactor 18 Amps in existing model and make ncluding after taking out old unserviceable one, complete all as specified and directed y Engineer-in-Charge.
29S& F Panel LED indication lamps (R/Y/B) complete all as specified and directed y Engineer-in-Charge.
30S&F Rotary switch of existing make L&T complete all as specified and directed y Engineer-in-Charge.
31S&F in repairs digital volt meter ,415 volts,including after taking out old unserviceable one complete all as specified and directed y Engineer-in-Charge. Make: AE/C&S/ABB
32S&F in repairs digital Ammeter,415 volts grade,100 Amps rating,including and after taking out old unserviceable one all as specified and as directed by Engr-In-Charge.AE/C&S/ABB
33S& F in capacitor 3 phase, 5 KVAR complete all as specified and directed y Engineer-in-Charge.
34S& F in capacitor 3 phase, 10 KVAR complete all as specified and directed y Engineer-in-Charge.
35S& F in capacitor 3 phase, 25 KVAR complete all as specified and directed y Engineer-in-Charge.
36S& F in capacitor 3 phase, 2 KVAR complete all as specified and directed y Engineer-in-Charge.
37S& F in capacitor 3 phase, 3 KVAR complete all as specified and directed y Engineer-in-Charge.
38Supply and install reactive power manager in existing APFC panel complete all as specified and directed y Engineer-in-Charge.
39M&L for servicing/testing of APFC(Automatic Power Factor Control) panel including checking of all internal connetions and replacement of spares if required complete all as specified and directed y Engineer-in-Charge. Note - Spares to be measured and paid separately
40M & L for High quality powder coating on electric panels (Cubicle) installed at different places with synthetic enamel paint of suitable colour including and after scrubbing all body surface to get all foreign particles removed off,applying one coat of metal primer by disconnecting,removal of all accessories like bas bar, CTs,MCCBs and all wirings,equipments and refix with new Gun metal nut,bolt and washer complete with new copper lead wiring complete all as specified and directed y Engineer-in-Charge.
41Boring of Holes under road, Pavement, hard Standing by trenchless technology using ultra Sound technique and necessary machine withHDPE Pipe, PN 10,100 mm dia complete all as specified and directed y Engineer-in-Charge.
42M&L for earthing complete for pole with galvanized mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtr below ground level connected by using galvanised iron strip 25 X 4mm as earthing lead size by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 40mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, all excavation and earth work & connectiing the earthing to an earthing test point as specified and testing on complete all as specified and directed y Engineer-in-Charge.
43Supply, laying and fixing in position in repairs galvanized iron pipe 80 mm bore light grade fixed to pole with mild steel clamps of required size or laid through wall/under floor/under road/in trenchesduly painted with two coat of black metallic paint after aprimer coat of red oxide complete all as Specified and Directed by Engr-In-Charge.Make : Jindal/Tata/Prakash Surya
44All as per item No. 43 here in above but 50 mm dia complete all as specified and directed y Engineer-in-Charge.
45All as per item No 43 here in above but 40 mm dia complete all as specified and directed y Engineer-in-Charge.
46Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, front access free standing/Wall mounted, dust and vermin proof (IP 65 ingress protection) main LT Panel(In door type) suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of 50 KA for 1 sec , fabricated from 2 mm thick CRCA sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement mounted on angle iron frame made out of 50x50x6 mm frame with 6 nos legs not less than 45 cm fixed with nuts bolts of suitable size,including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below :-
47Note : item No 46 continued ....../-. LT Panel shall have provision for entry of cables from the top or bottom as required All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position Suitable arrangement shall be made for termination of multiple incoming cables All kA values indicated shall be Ics breaking capacity. General Arangement drawings shall be got approved by GE before fabrication Pre - dispatch inspection of panel shall be carried out by Rep. of accepting officer within overall cost quoted. INCOMER : (i) MCCB 400 Amp, 35 KA, 4 pole 415 volts.1 Nos (incoming), (II) Digital Volt Meter (0-500V) =01 No., (iii) Digital Amps Mtr (0-200)=01 No.with suitable CT rating (iv) Selector Switches-02 Nos (3 phase volt meter,3 phase Ammeter), (v) Lamp LED,220 Volt, - 03Nos OUTGOING : (i) MCCB 160 Amp, 25 KA, 4 pole 415 volts - 02 Nos (ii) MCCB 125 Amp, 16 KA, 4 pole 415 volts - 08 Nos Note :MCCBs shall have adjustable thermal setting
48Design, fabrication, assembly, wiring and supply, installation, testing and commissioning of front operated cubicle type compartmentalised, front access free standing/Wall mounted, dust and vermin proof (IP 65 ingress protection) main LT Panel(In door type) suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for fault level of 50 KA for 1 sec , fabricated from 2 mm thick CRCA sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement mounted on angle iron frame made out of 50x50x6 mm frame with 6 nos legs not less than 45 cm fixed with nuts bolts of suitable size,including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below :-
49Note : item No 48 continued ....../-. LT Panel shall have provision for entry of cables from the top or bottom as required All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The Busbars insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be lockable in OFF position Suitable arrangement shall be made for termination of multiple incoming cables All kA values indicated shall be Ics breaking capacity. General Arangement drawings shall be got approved by GE before fabrication Pre - dispatch inspection of panel shall be carried out by Rep. of accepting officer within overall cost quoted. INCOMER : (i) MCCB 315 Amp, 35 KA, 4 pole 415 volts.1 Nos (incoming), (II) Digital Volt Meter (0-500V) =01 No., (iii) Digital Amps Mtr (0-200)=01 No.with suitable CT rating (iv) Selector Switches-02 Nos (3 phase volt meter,3 phase Ammeter), (v) Lamp LED,220 Volt, - 03Nos OUTGOING : (i) MCCB 160 Amp, 25 KA, 4 pole 415 volts - 03 Nos (i) MCCB 125 Amp, 16 KA, 4 pole 415 volts - 03 Nos (i) MCCB 100 Amp, 16 KA, 4 pole 415 volts - 01 No. Note :MCCBs shall have adjustable thermal setting
50Supply and install and commmissionng of LT bus bar chamber CPRI approved out door type with sloping canopy of size 600x600x600mm made out of 3.15 mm thick CRCA sheet, panel shall be powder coated siemens grey shade mounted on 40x40x6 mm MS angle iron frame 90 cms height erected in ground with PCC foundation 1:4:8 with 40mm stone aggregate including supply and fixing insulated aluminium bus bar of size 50x 6mm for three phase and neutral 200 mm length respectively mounted on insulators and terminating with suitable cable with glands and provision of one MCCB 63 Amps,3 pole ,415 mps, 50 Hz of breaking capacity 25 KA as incomer complete all as specified and directed y Engineer-in-Charge.
51M & L for servicing of volatge stabilizer auto servo controlled on balanced type 3 ph naturally cooled of capacity 160 KVA of make : Volina, by disconnecting the LT cables and draining out oil complete and taking out the coreand checking the continuity and insulation values of all three phases, reinsulating if required and inspecting and replacing the PCB and servicing of breaker, removing and cleaning the sludge from the tank, refilling the oil after filteringby using online centrifuge machine and obtain the dielectric strength of oil not below 60 KV at 2.5 mm gap including testing of volatge stabilizer by reconnecting the disconnected cables and calibrating complete all as specified and directed y Engineer-in-Charge. Note:The rate shall also deemed to be included the rate for Technician, Electrician,and labours.
52Preparing of old faded painted surface of 9 m long steel tubular pole complete including all accessories such as cross arms, bracings, brackets etc and painitng with two coats of aluminium paint of approved tint including writing pole number with paint same as existing earlier and white/blue colour of synthetic enamel for 30 cm strip upto 1.5 meter height from ground level complete all as specified and directed y Engineer-in-Charge.
53Supply and fix Energy saving LED street light with PDC Aluminium body and toughened glass visor fitted in frame,secondary optical lens for superior light distribution roadway street light fittingwith high power LEDs of 45 Watt as light source with electronic driver complete all as specified and directed y Engineer-in-Charge.
54Supply and fix Energy saving LED street light with PDC Aluminium body and toughened glass visor fitted in frame,secondary optical lens for superior light distribution roadway street light fittingwith high power LEDs of 60 Watt as light source with electronic driver complete all as specified and directed y Engineer-in-Charge.
55Supply and fix Energy saving LED street light with PDC Aluminium body and toughened glass visor fitted in frame,secondary optical lens for superior light distribution roadway street light fittingwith high power LEDs of 72 Watt as light source with electronic driver complete all as specified and directed y Engineer-in-Charge.
56Supply and fix energy efficient LED flood light new Generation Energy Saving LED flood light powder coated PDC Aluminium body with toughened glass visor long life save exclusive-cast aluminium flood light fitting with high power LEDs 200 Watt in existing high mast light/tower upto 40 mtr heightas light source including necessary fixing arrarangements complete all as specified and directed y Engineer-in-Charge. Note - Repair/raplacement of fitting through hydra crane etc cost included in this unit quoted rate .
57Supply and fix energy efficient LED flood light new Generation Energy Saving LED flood light powder coated PDC Aluminium body with toughened glass visor long life save exclusive-cast aluminium flood light fitting with high power LEDs 150 Wattin existing high mast light/tower upto 40 mtr height as light source including necessary fixing arrarangements complete all as specified and directed y Engineer-in-Charge. Note - Repair/raplacement of fitting through hydra crane etc cost included in this unit quoted rate .
58Supply and fix energy efficient LED flood light new Generation Energy Saving LED flood light powder coated PDC Aluminium body with toughened glass visor long life save exclusive-cast aluminium flood light fitting with high power LEDs 100 Watt in existing high mast light/tower upto 40 mtr height as light source including necessary fixing arrarangements complete all as specified and directed y Engineer-in-Charge.
59Repair and maintenance of existing street, Security and highmast light fittings 45/60/72/150/250 watts LED fittings of any type and capacity including cleaning of perplex cover where ever required and tightening of loose connection or brought it down for repair and fix it back after repair on the pole complete all as specified and directed y Engineer-in-Charge. Note: The Spares required for the maintenance of item No 17will be measured & paid separately including labour and the rate quoted is deemed to beincluded only for checking, removing, re fixing, cleaning & tightening etc.
60Supply and fixing of terminal box made out of SMC with hinged door and locking arrangements of size 300x200x150 mm Including 4 way connector, MS Clamps suitable for pole ,PCC/MS/GI/rail etc. with bolt, nut and washer,electrical connections incl MCB SP 6-32 Amps complete all as specified and directed y Engineer-in-Charge.
61Supply and fix two single core PVC insulated and sheathed copper conductor cable 2.5 Sqmm nominal size and one single corePVC insulated and sheathed copper conductor cable 1.5 Sqmm nominal size for earth continuity from main lines to the street light fittings after removing u/s one complete all as specified and directed y Engineer-in-Charge.
62M&L in repairs,two single core PVC insulated cable with copper conductor multi stranded 1.5 Sqmm duly drawn through and including PVC conduit suitable size as sub main with continuous earth wire 1.5 Sqmm size and connecting to common earth dolly complete all as specified and directed y Engineer-in-Charge. (Flexible Copper Wire Used In FRLS)
63Supply and fix three core PVCconductor copper round cable 6 Sqmm for connection from high mast light fittings complete all as specified and directed y Engineer-in-Charge.
64Supply and fixing PVC insulated sheathed aluminum conductor cable 10 sqmm two single core 1100 volts grade multistanded conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connectionscomplete all as specified and directed y Engineer-in-Charge.
65Supply and Fix MCB TPN 63 Amps, 10 KA rupturing capacity complete all as specified and directed y Engineer-in-Charge.
66Supply and Fix MCB TP 40 Amps, 10 KA rupturing capacity complete all as specified and directed y Engineer-in-Charge.
67Supply and fix driver suitable for 45 Watt LED light fittings and testing completeincluding taking down the same complete all as specified and directed y Engineer-in-Charge.
68Supply and fix driver suitable for 60 Watt LED light fittings and testing completeincluding taking down the same complete all as specified and directed y Engineer-in-Charge.
69Supply and fix driver suitable for 70 Watt LED light fittings and testing completeincluding taking down the same complete all as specified and directed y Engineer-in-Charge.
70Supply and fix driver suitable for 150 Watt LED flood light fittings and testing completeincluding taking down the Same all as specified and directed.
71Supply and fix driver suitable for 200 Watt LED lood light fittings and testing completeincluding taking down the same complete all as specified and directed y Engineer-in-Charge.
72Supply and fixing GI bracket in repairs made out of 32 mm bore,light grade 1.2 m long bent to shape suitable for street light fitting including MS flat clamp 50 x 6 mm 2 Nos for each bracket with nut & bolt complete all as specified and directed y Engineer-in-Charge.
73Supply and fixing LED-Post top 40Watts,230 V, IP 65, 5700K rated with control driver with efficiency 90% pure coated aluminium die cast and spun aluminium body with clear/opal diffuser suitbale for landscape lighting for uniform illumination prewired including all accessories and connecting up with twin core copper conductor with suitable size complete all as specified and directed y Engineer-in-Charge.
74Supply and fix steel tubular swaged poles type 410 SP-31 (9.0 meter long) complete with CI base plate and finial including foundation and coping complete all as specified and directed y Engineer-in-Charge.
75M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate in foundation complete all as specified and directed y Engineer-in-Charge.
76M&L for PCC 1:3:6 type C1 using 20mm graded stone aggregate for stay and couping for poles including necessary form work to exposed surface finished smooth and even complete all as specified and directed y Engineer-in-Charge.
77Cutting tree branches below, top and around the street light pole/fitting and clearing not less than two mtrs around the pole and keeping the clearance by trimming the branches includingclearing the site by depositing the branches to a distance not exceeding 50 m complete all as specified and directed y Engineer-in-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail