Public Administrative Department Local Bodies Closing in 0 days TDR #37790115

Tender For Construction Of Boundary Wall And Building Hariya School. At - Saradhu, G.P- Saradhu, Block- Tandwa, District- Chatra

Issued by Local Bodies · tandwa, Jharkhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
29 May 2023
0 days left
EMD
71000
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tandwa → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Boundary Wall And Building Hariya School. At - Saradhu, G.P- Saradhu, Block- Tandwa, District- Chatra

BOQ

Name of Work:Construction of boundary Wall & Building HariyaSchool.At - Saradhu, G.P- Saradhu, Block- Tandwa, District- Chatra.
Sl. No. Item Description
1Earthwork in excavation in foundation trenches in ordinary soil and disposal of excavatedearth as obtained to a distance upto 50 M. including all lifts, levelling,ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specificationand direction of E/I
2Filling in founclation trenches and plenth in layers not exceeding 150 mm thick wellwatered, rammed, fully compacted and fine cressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of \"1.SlVl all complete as per building specification and direction of E/
3Providing coarse clean sand in filling in foundation trenches or in plirrth including rammrng and watering in layers not exceeding 150mm thick wiih all leads and lifts including cost of all rnaterials, labour, royaity and taxes all complete as per buildingspecrfication anci direction of E/l
4Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per bLrilding specification and directton of E/l.
5Providing P.C.C.M-l50 rn nominal mrx of (1:2:4) in foundation with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sancl of F M.2 5 to 3 including screening, shutteringmixing cement concrete in mixer and placrng in position\" lvibrating, strrking, curing, taxes and royalty all complete as per I fui,O,ng specification and direction of Engineer-in-charge\"
6Providng R c c M _ 200 wiih nominat mix of ( 1:\"1:5:3 ) rn foundation trench plinth with approvecl quality of stone ---- do ----
7Providing R.C.C. M200 with nominal mix of (1:1.5:3) in column…………do……………do…………
8Centring and shuttring including strutting, proping etc and removal of form for………
9Plinth beam
10Column
11Providing designation75B brick work in C.M.(1:6) in Superstrecture………..do…………….do………….
12Providing R.C.C. M 200 with nominal mix of (1:1.5:3) in band at Lintel level with …………..do………..do……..
13Providing Tor seel reinforcement of 8mm,10mm,12mm,16mm,20mm dia……do………….do………….e/I 8 m.m. Dia
1410 m.m. Dia
158 m.m. Dia
16Providing 12mm thick cement plaster (1:6)…………….do…………..do………………
17Supplying,Fitting and fixing MS Grillmade of 20x6 mm ms Flat……do….do……..all complite as per direction of E/I.
18Finishing walls with premium acrylic smooth exterior paint with sillicone additives of requited shade . New work : 2 or more coats applied @1.43 Ltr/10sqm over and including base coat of waterproofing cement paint applied @2.2 Kg/10 sqm
19Providing two coats of painting with ready mixed paint over a coat of primer of red lead paint over steel surface -do- -do- all complete job.
20Supplying, fitting and fixing M.S. grill gate with M.S. grills made of 20 x 6 mm M.S flats or16mm M.S square bars fitted on 25 x 5 x 6mm M.S angle frame of size 60 x 60 x 6mm -do- -do- all complete job as per specification and direction of E/I.
21Providing two coats of painting with ready mixed paint over a coat of primer of red lead paint over steel surface -do- -do- all complete job.
22Earlh work in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance up to 50M -do- -do- all complete job. (5.1.1 + 5.1.2)
23Providing course cleansand filling in foundation trenches -do- -do- all complete job as per specification & direction of E/I. (5.1.10)
24Providing designation 75B brick flat soling joint filled with local sand -do- -do- all complete job. (5.6.3)
25Providing P.C.C. (1:2:4) in foundation with Stone Chips -do- -do- all complete job. (5.3.5)
26Providing R.C.C.M-200 with nominal mix of (1:1.5:3) infoundation & column with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 excluding the cost of centring & shuttering mixing cement concreting in mixer and placing in position vibrating striking curing, taxes and royalty all complete as per building specification and direction of E/I.(5.3.9.1)
27Providing R.C.C.M-200 with nominal mix of (1:1.5:3) infoundation & column with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 excluding the cost of centring & shuttering mixing cement concreting in mixer and placing in position vibrating striking curing, taxes and royalty all complete as per building specification and direction of E/I.(5.3.10)
28Providing 75B brick work in C.M. (1:6) in foundation and plinth -do- -do- all complete job. (5.2.6)
29Providing 50mm thick Damp Proof Course with cement concrete M-200 with nominal mix 1:2:4 with approved quality of stone chips of 20mm to 6mm (20mmto 10mm : 10mm to 6mm stone chips 2:1) size graded and clean coarse sand of F.M. 2.5 to 3 including screening, mixing cement concrete in mixer with 5% Cico or any other approved water proofing compound and placing in position, striking, curing taxes and royalty and complete as per building specification and direction of E/I.5.3.5
30Providing 75B brick work in C.M. (1:6) in super structure -do- do- all complete job. (5.2.14)
31Providing R.C.C.M-200 with nominal mix of (1:1.5:3) in Roof Slabl with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 excluding the cost of centring & shuttering mixing cement concreting in mixer and placing in position vibrating striking curing, taxes and royalty all complete as per building specification and direction of E/I.(5.3.11)
32Providing 6mm thick Ceiling Plaster in CM (1:4) -do- -do- all complete job as per specification and direction of E/I. (5.7.6)
33Providing 12mm thick Cement Plaster in CM (1:6) -do- -do- all complete job as per specification and direction of E/I. (5.7.3)
34Providing1.5 m.m. cement punning including curing carriage of water with all leads and lift do--do all as per specification anddirection of E/I. (5.6.7)
35Providing 25 m.m. thick first class patent stone flooring (1:2:4) with stone chips in two layers ,bottom layer 19 m.m. thick (1:2:4)with 12m.m. to 6 m.m. size graded stone chips do--do all as per specification anddirection of E/I. (5.6.7)
36Providing 16mm dia Fan Hoocks -do- -do- all complete job.(5.5.13)
37Supplying, fitting and fixing M.S grill made of 20 x 6mm M.S. flat -do- -do- all complete job. (5.5.12)
38Providing primer one coat of read laid paint with two coats ofpainting with ready mixed Paint ofapproved shade and make over steel surface including cleaning thesurface thoroughly, scaffolding and taxes all complete as per building specification and direction of E/I.(5.8.41+5.8.43)
39Providing two coats of Oil Bound Distemper of approved shade and make over a coat of cement primer over old surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffold (5.8.18)
40Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) (DSR-13.46.1)
41Providing M.S. Reinforcement with cutting, bending and binding etc. -do- -do- all complete job. (5.5.5 b)8 m.m.20%@6.51 - 5.5.4
4210 m.m.20%@6.51 - 5.5.5. (a)
4312 m.m.20%@6.51-5.5.5 (b)
4416 m.m.20%@6.51 - 5.5.5 ©
4520 m.m.20%@6.51- 5.5.6
46Providing and fixign on wall face unplatictzed rigid pvc rain water pipes confirming to IS 13592 type A including jointing with seal ring confirming to is 5382 leaving 10 mm gap for thermal expansion. Single socket pipes. 110 mm dia.(DSR-12.41.2)
47Providing and fixigng unplatictzed pvc pipes clips of approve design to unplatictzed rigid pvc rain water pipes by means 50 x 50 x 50 mm hard wood plugs , screwed with M.S. screw of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete - 110 mm (DSR- 12.43.2)
48Centring shuttring including strutting, propping etc all complite as per direction of E/I.
49Roof Slab
50Column
51Wiring forfan Point/Light Point/Edjust fan call bell point with 1.5sq. Mm F.R P.V.C insulated copper conuctor single core cable in surface - recessed P.V.C conduit, with modular tipe switch phenolic laminated sheet, suitable size P.V.C - G.I. box etc . 1.3 group A Group A- 1.3.1
52GroupB -1.3.2
53Wiring for Submain wiring along nith earth wire ninth the Foloing do……..do.1.7.12x1.5sqmm.+ 1x1.5 sqmm Earth wire
541.7.22x2.5sqmm. +1x2.5sqmm. Earth wire
551.7.22x4sqmm. +1x4sqmm. Earth wire
56Supplying and fixing Folloing site p.v.c Conduit along with accessorisin surface slace recess including cutting the wall and making good the same in case recessed conduit as requred
57Supplying and fixing P.v.c /G.l. box of folloing sizes on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required .
58Supplying and fixing 6amp and 32amp rating 240 volts B Serico MINIATURE circuit breaker suitable four lighting and athor loads of fllowing poles in the existingMCB/DB complete with conection, testing and commissioning etc. as requried. 2.11.1amp Single Pole B Serice.
59S/f/f to pin 5amp. Celling rose on the existing junction box/wooden block including conection etc as requried.
60S/F modular type switch/socket......do......5/6 amps, one way switch
615/6 amps, two way socket
62S/F/F Stepped type electronic fan regulator .....do...do....
63Supplying and fixing LED Tube light 10/12W
64Supplying 48\" dia celling fan
65Carriage of materials.(i) Steel & Cement - Lead - 10 Km. =
66(ii) Sand - Lead - 10 Km. =
67(iii) Stone Chips - Lead - 15 Km. =
68(iv) Bricks - Lead - 8 Km. =
69Add 18% GST
70Add1% LC
71Add Phototgrapahy & Signboard

AI Tender Summary

OUR REF NO 37790115
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 29-05-2023
Authority
Authority Name Zilla Parishad
Work Description Construction Of Boundary Wall And Building Hariya School. At - Saradhu, G.P- Saradhu, Block- Tandwa, District- Chatra
Basic Detail
Tender No Nit No. 03/2023-24, Group No. 06
Bidding Type Tender
Location
City tandwa
State Jharkhand
Key Dates
Publish Date 22 May 2023
Submission Date 29 May 2023
Open Date 31 May 2023
Finance
Tender Value Ref. Documents
Tender Fee 5000
EMD 71000
Exemption Not Available
Document List
cde6b180-0b7f-4a6c-afcc-d6a394333bea.html
BOQ_95806.xls
TenderDocument.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 22, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
May 29, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 31, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

cde6b180-0b7f-4a6c-afcc-d6a394333bea.html

xls

BOQ_95806.xls

pdf

TenderDocument.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender