Tender For Periodical Services, Repair To Flooring/Plastering, Tilling And Repair/Replacement Of Internal Wiring Socket, Switches Etc And Other E/M Items At Af Stn Naraina In Aor Of Ge (Af) Faridabad, New Delhi-Delhi

Military Engineer Services-MES has published Tender For Periodical Services, Repair To Flooring/Plastering, Tilling And Repair/Replacement Of Internal Wiring Socket, Switches Etc And Other E/M Items At Af Stn Naraina In Aor Of Ge (Af) Faridabad. Submission Date for this Tender is 17-06-2023. Electromechanical Machinery Tenders in New Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

37780371
Corrigendum : Tender For Periodical Services, Repair To Flooring/Plastering, Tilling And Repair/Replacement Of Internal Wiring Socket, Switches Etc And Other E/M Items At Af Stn Naraina In Aor Of Ge (Af) Faridabad
Open Tender
Indian
Delhi
New Delhi
17-06-2023

Tender Details

Periodical Services, Repair To Flooring/Plastering, Tilling And Repair/Replacement Of Internal Wiring Socket, Switches Etc And Other E/M Items At Af Stn Naraina In Aor Of Ge (Af) Faridabad

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 94000.0 /-
Tender Value
INR 47 Lakhs /-

BOQ Items

Name of Work: PERIODICAL SERVICES, REPAIR TO FLOORING/PLASTERING, TILLING AND REPAIR/REPLACEMENT OF INTERNAL WIRING SOCKET, SWITCHES ETC AND OTHER E/M ITEMS IN AOR OF GE (AF) FARIDABAD
Sl. No. Item Description
1Demolition/Dismantling of Brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc complete all as specified and directedby Engineer-in-Charge.
2M&L for Brickwork with subclass "B" bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directedby Engineer-in-Charge.
3All as per item No 02 above here in but except bricks complete all as specified and directedby Engineer-in-Charge.
4M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete all as specified and directedby Engineer-in-Charge.
5Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls, Ceiing etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directedby Engineer-in-Charge.
6M&L for rendering 15 mm thick cement plaster in CM 1:6 onbrick Work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directedby Engineer-in-Charge.
7M&L, Rendering 15mm thick in CM 1:4 onof brick work or concrete surfacefinish ever and smooth (w/o using extra cement) incl WPC as per user manual complete all as specified and directedby Engineer-in-Charge.
8M&L for rendering 10mm thick in CM 1:3 over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directedby Engineer-in-Charge.
9M & L for preparation of new plastered surface and applying two coats of oil emulsion distemperon wall over one coat of primer incl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directedby Engineer-in-Charge.
10M&L for preparation of new plaster surface & apply twocoats of cement based paint over a coat alkali primer resistanceincl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directedby Engineer-in-Charge.
11M & L for preparation of new plastered surface and applying two coats of oil emulsion distemperon ceiling over one coat of primerincl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directedby Engineer-in-Charge.
12M&L fortwo coat ofAcrylic smooth exterior emulsion paint over one coat of acrlic primer incl one layer of 3mm thick wall care compound of altek/birlaputty for exterior/interior on old scraped wall/ceiling surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directedby Engineer-in-Charge. Note : Colour and make as approved by Engr-in-Charge.
13M&L forone coat ofAcrylic smooth exterior emulsion paint over one coat of acrlic primer incl one layer of 3mm thick wall care compound of altek/birlaputty for exterior/interior on old scraped wall/ceiling surfaces and obtain smooth finish using sand paper complete all as specified and directedby Engineer-in-Charge.. Note : Colour and make as approved by Engr-in-Charge.
14M&L forpreparation of old surfaces by removal of existing treatmen and applying two coats of oil emulsion distemper over a coat of primer on surface of walls incl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directedby Engineer-in-Charge.
15M&L for preparation of old surfaces by removal of existing treatment and applying two coats of distemper oil emulsion on ceiling over one coat of primerincl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directedby Engineer-in-Charge.
16M&L forpreparation of old surfaces by removal of existing treatmen and applying one coats of oil emulsion distemper over a coat of primer on surface of wallsincl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directedby Engineer-in-Charge.
17M&L for preparation of old surfaces by removal of existing treatment and applying one coats of distemper oil emulsion on ceiling over one coat of primerincl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directedby Engineer-in-Charge.
18M & L for preparation of old wall surfaces by removal of existing treatmentand apply two coats of cement based paint over a coat alkali primer resistanceincl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directedby Engineer-in-Charge.
19M & L for preparation of old surfaces by removal of existing treatmentand apply one coats of cement based paint over a coat alkali primer resistance incl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directedby Engineer-in-Charge.
20M&L forpreparation of old surfaces by removal of existing treatmen and applying two coats of white wash on surface of walls complete all as specified and directedby Engineer-in-Charge.
21M&L forpreparation of old surfaces by removal of existing treatmen and applying two coats of white wash on surface of ceiling complete all as specified and directedby Engineer-in-Charge.
22M&L forpreparation of old surfaces by removal of existing treatmen and applying one coats of white wash on surface of walls complete all as specified and directedby Engineer-in-Charge.
23M&L forpreparation of old surfaces by removal of existing treatmen and applying one coats of white wash on surface of ceiling complete all as specified and directedby Engineer-in-Charge.
24M&L for coral wall texture paint flasks type consisting of fiber natural gem, semi-precious pigmented granules, pearl and spary texture of high resistance, fire proof polymer alkali resistance, anti-corrosion and anti-condensation with natural stone, lime stone quartz etc. that given a scam less wall surface without joints, reples water ultra violet rays from sunlight including removing of, alage and fungus applied on wall or ceiling with trowel and roller complete all as specified and directedby Engineer-in-Charge.
25M & L for one coat of synthetic enamel paint on steel surface including preparation of old steel surface width or girth exc 10cm complete all as specified and directedby Engineer-in-Charge.
26M & L for one coat of synthetic enamel paint on steel surface including preparation of old steel surface width or girth n. exc 10cm complete all as specified and directedby Engineer-in-Charge.
27M&Lfor one coats of synthetic enamel paint on wooden surfaces of any description over 10cm width or girth including preparation of old surfaces complete all as specified and directedby Engineer-in-Charge.
28Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris complete all as specified and directedby Engineer-in-Charge.
29M & L for 50 mm thick PCC 1:3:6 type C-2 (using 40 mm agg. ) as in plinth protection / path/ any paved area complete all as specified and directedby Engineer-in-Charge.
30M&L 75mm thick PCC type D-2, 1:4:8 (using 40mm graded aggregate) as in sub base complete all as specified and directedby Engineer-in-Charge.
31M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 60mm thickness, with grey cement, pigmentincl 25mm thick sand filling complete all as specified and directedby Engineer-in-Charge.
32M & L for sand filling under floors or in foundationincluding watering and consolidation complete all as specified and directedby Engineer-in-Charge.
33M & L for chequered tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling complete all as specified and directedby Engineer-in-Charge.
34M&L for 25 mm thick PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in laying offloor/sub base finishes complete all as specified and directedby Engineer-in-Charge.
35M&L for non skid ceramic coloiured tiles 7 to 8 mm thick (square/rectangular ) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm as in floor of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles,15 mm thick rendering in bedding layer or screed bed in cement mortar (1:6) in floors incl dismantling tiles etc complete all as specified and directedby Engineer-in-Charge.
36All as per item No 35 above item but here- in area of each tile exe 0.11 sqm but n.exe 0.18 sqm, in floors & dado etc complete all as specified and directedby Engineer-in-Charge.
37M& L for Glazed ceramic jointless light/coloured group of size 300/350mmx450/600mm, thickness not less than 6mm as in vertical surfaces such as skirting/dado etc., set and jointed in neat cement slurry and pointed with white cement and pigment to match,laid over and including 10mm thick plastering in cement mortar 1:4,incl dismantlingtiles etc complete all as specified and directedby Engineer-in-Charge. Note : shade & design as approved by EIC/GE
38M&L for coloured Non Skid Ceramic tiles7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm , in floors of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles,15 mm thick rendering in bedding layer or screed bed in cement mortar (1:6) in floors incl dismantling tiles etc complete all as specified and directedby Engineer-in-Charge.
39M&L for Virified tiles light shade /dark shade 10 mm thick (square/ rectangular) polished, area of each tiles not exc 0.36 sqm , in floors, dado , skirtingetc. set and jointed in neat cement slurry over 15 mm thick screed bed or bedding layer in CM 1:4 for laying floor finishes and pointed in white or coloured cement to match and incl dismantling tiles etc complete all as specified and directedby Engineer-in-Charge.
40Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc.laid, bedded and pointed in any mortar complete all as specified and directedby Engineer-in-Charge.
41M&L for Granite 20 mm thick (of any type ) (table runned and polished ) in floors steps , jamns, pillars,window-cills,cooking plateforms and vertical surfaces bedded and jointed with grey cement slurry and pointing in white ciment (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directedby Engineer-in-Charge.
42M&L rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directedby Engineer-in-Charge.
43M & L for viterous china squating pan of (Orrissa Pattern) size 580x440 mm white with "P" or "S" trap front or back inlet and integral foot rest (excluding flushing cisteern and flush pipe) fixed in repair including lime concrete bedding as required set complete all as specified and directedby Engineer-in-Charge.
44S&F for Vitreous China wash down water closet pan (pedestal pattern) with trap, white (excluding fixing bolts, flushing cistern and flush pipe) incl connection to drain and flushing pipe complete all as specified and directedby Engineer-in-Charge.
45S&F in repair ofPVC flushing cistem low level white with all accessories of 10 ltrs capacity incl flushing pipe, brackets and taking down of old CI/PVC flushing cistern complete all as specified and directedby Engineer-in-Charge.
46S&F in repair for 15 mm bore Twin one angle valve/ bib tap cast copper alloy chromium plated, fancy type, screwed down high pressure, screwed both ends for ironpipe or for union complete all as specified and directedby Engineer-in-Charge.
47S&F CP jetfor EWC along with pvc connection complete all as specified and directedby Engineer-in-Charge.
48S&F in repair for Toilet paper holder,stainless steel,fixed with and including chromium plated brass screws and and wooden/plastic cleatson walls,complete all as specified and directedby Engineer-in-Charge. Make:Jaquar Cat Part No. AKP 35753PS or equivalent.
49S&F in repair for Health faucet brass CP with 8mm dia 1.2 mtr long flexible pipe and wall hook fixed with brass chromium plated screws,complete all as specified and directedby Engineer-in-Charge. Make:Jaquar Cat Part No. ALD CHR-573 or equivalent .
50S&F in repair forVitreous China wash basin (Pedestal pattern), White, flat back, size550x400 mmexcluding taps, waste, chain and plug and porcelain stopperbut including brackets complete all as specified and directedby Engineer-in-Charge.
51M&L in repair for 600x450 mmbeveled edge mirror of selected quality glass, mounted on 6 mm thick AC building board and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directedby Engineer-in-Charge.
52S& F in repair for swan neck pillar cock fancy typechromium plated screw with iron pipe incl all fittings in repairs complete all as specified and directedby Engineer-in-Charge.
53S&F in repair CP brass centre hole mixer without pop up waste system 15mm bore for mixing hot and cold water screwed down for iron pipe for WHB, complete all as specified and directedby Engineer-in-Charge.
54S&F in repair for Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms)complete all as specified and directedby Engineer-in-Charge.
55S&F in repair for liquid soap container of PTMT fixed with and incl CP brass screws and wooden/plastic cleats complete all as specified and directedby Engineer-in-Charge.
56S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directedby Engineer-in-Charge.
57S & F in repairvitreous china urinals, half stall type (635x450mm) , complete including providing and fixing , bedding urinal against wall in cement mortar 1:2 , pointing around urinal back in cement , grating and union for discharge pipe, (Exclusive of fixing supply pipe to flushing cistern, trap&waste pipe complete all as specified and directedby Engineer-in-Charge.
58S&F in repair for Curverbshape urinal partition with frosted glass 8mm thk size 900x450 mm complete all as specified and directedby Engineer-in-Charge.
59S&F in repair for Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directedby Engineer-in-Charge.
60S&F in repair for 32 mm dia Waste coupling of PTMT (half or full threaded) suitable for urinal . (Minimum weight 32mm45gms) complete all as specified and directedby Engineer-in-Charge.
61S&F in repair for Bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms/40mm-270 gms),complete all as specified and directedby Engineer-in-Charge.
62S & F in repair Bib tap CP fancy type long body 15 mm bore with will crutch or buttewrfly handle screwed down screwed to iron pipe complete with all fittings complete all as specified and directedby Engineer-in-Charge.
63S & F in repair Stop cock /angle CP fancy type 15 mm bore screwed down high pressure with crutch or butterfly handle & screw both end for iron pipe or for Unions complete all as specified and directedby Engineer-in-Charge.
64S & F in repair Stop cock concealed long shank chromium plated fancy type 15 mm borescrewed down high pressure with crutch or butter fly handle complete all as specified and directedby Engineer-in-Charge.
65S&F in repair for wall mixer with provision for overhead shower with 115 mm long bend pipe on upper side, connecting legs and wall flanges, complete all as specified and directedby Engineer-in-Charge. Make: ESS cat part No EC-10 or equivalent.
66S&F in repair for Brass chromium plated shower rose of 200mm size with arm and with or without swivel joints, complete all as specified and directedby Engineer-in-Charge. Make: Jaquar Cat Part No. OHS 1779 for shower and SHA 49483 for arm or equivalent.
67S&F in repair for Ball valve, high pressure with PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe orfixed of size 20 mm bore, fixed in repairs.(Min Wt 20mm- 210 gms) complete all as specified and directedby Engineer-in-Charge.
68S&F in repair for Ball valve, high pressure with PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe orfixed of size 15 mm bore, fixed in repairs.(Min Wt 20mm- 210 gms) complete all as specified and directedby Engineer-in-Charge.
69S&F in repair for Soap dish,fixed to plugs with chromium plated brass screws complete all as specified and directedby Engineer-in-Charge.
70S&F in repair for PVC connections 60cm long superior quality with PTMT nut on both side complete all as specified and directedby Engineer-in-Charge.
71S&F in repair grating round 125mm size of CP complete all as specified and directedby Engineer-in-Charge.
72S&F stainless steel pegset of six suitable size of length complete all as specified and directedby Engineer-in-Charge.
73Taking up or down 15 mm dia bore steel tubing and connection including cleaning for refixing or removed to store complete all as specified and directedby Engineer-in-Charge.
74S&F for GI tubing 15mm boremedium grde with all fittings and fixed complete to wall and ceiling or laid in floors etc incl cutting chases in brick wall pinning in making good in CM 1:3 to facings where required all as directed and specified.
75Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 20 mm dia bore complete all as specified and directedby Engineer-in-Charge.
76S&F GI tubing 20 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directedby Engineer-in-Charge.
77Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 25 mm dia bore complete all as specified and directedby Engineer-in-Charge.
78S&F GI tubing 25 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directedby Engineer-in-Charge.
79S&F for 110mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cmlength "medium grade " with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and directedby Engineer-in-Charge.
80All as per item No 79 above but laid in trench or in floor complete all as specified and directedby Engineer-in-Charge.
81S&F for 110mm bore PVC Gully Trap setting / jointed with solvent cement complete all as specified and directedby Engineer-in-Charge.
82S&F for 110mm bore PVC bends/junctionany radius complete all as specified and directedby Engineer-in-Charge.
83S&F for 75 mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cmlength "medium grade " with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and directedby Engineer-in-Charge.
84All as peritem No 83above but laid in trench or in floor complete all as specified and directedby Engineer-in-Charge.
85S&F for 75 mm bore PVC bends/junctionany radius complete all as specified and directedby Engineer-in-Charge.
86S&F PVC (SWR) floor trap, plain with CP grating including jointing with solvent cement, 75mm diameter of outlet, complete all as specified and directedby Engineer-in-Charge.
87Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) completeincluding all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete all as specified and directedby Engineer-in-Charge.
88M&L for point wiring light point / bell point with single core PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through in existing concealed conduit, fixed on wall, ceiling with GI saddles GI screws, rawal plugs (concealed conduit wiring) with all fittings including Tee, junction boxes and provision of modular metal flush boxof suitable sizemodular white cover plate with frame for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with stranded coper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and directedby Engineer-in-Charge for following :-.NOTE:-After rewiring cutting chasing portion should be matched with existing finishes of walls.
89All as per item No 88 above but 5 Amp socket outlet, independent complete all as specified and directedby Engineer-in-Charge.
90All as per item No 88 above but on the same board complete all as specified and directedby Engineer-in-Charge.
91All as per item No 2 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 1.5 sq mm connected to common earth dolly
92M&L switch flush type bell push button 6 amp after dismantling old one complete all as specified and directedby Engineer-in-Charge. Make : Anchor/Fine/Indo Asian
93M&L for socket outlet 6A-2/3 Pin combined 2 module modular type complete all as specified and directedby Engineer-in-Charge.
94M&L for socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directedby Engineer-in-Charge.
95M&L for switch 6 amps modular type one one way complete all as specified and directedby Engineer-in-Charge.
96M&L for switch 16 amps modular type one one way complete all as specified and directedby Engineer-in-Charge.
97M&L for modular type fan regulator (Step type) , 120 W-1 module complete all as specified and directedby Engineer-in-Charge.
98M&L metal flush box 3 module complete all as specified and directedby Engineer-in-Charge.
99M&L metal flush box 6 module complete all as specified and directedby Engineer-in-Charge.
100M&L metal flush box 12 module complete all as specified and directedby Engineer-in-Charge.
101M&L for white cover plate with frame, 12 module complete all as specified and directedby Engineer-in-Charge.
102M&L for white cover plate with frame, 6 module complete all as specified and directedby Engineer-in-Charge.
103M&L for white cover plate with frame, 3 module complete all as specified and directedby Engineer-in-Charge.
104S&F bell Ding dong AC 230Volts single pole complete all as specified and directedby Engineer-in-Charge.
105S &F in replacement switch 16A,6pin,3module 220/230 Volts complete all as specified and directedby Engineer-in-Charge.
106S&F in replacement switch piano type 5 amp SP one way ISI Marked complete all as specified and directedby Engineer-in-Charge.
107S&Fin replacement 15 Amps SP one way ISI Marked complete all as specified and directedby Engineer-in-Charge.
108S&F in replacement socket outlet 3 pin 5 Amps flush type complete all as specified and directed by Engineer-in-Charge.
109S&F in replacement socket outlet 2-in-1, 3 pin 5 amp and 15 amps complete all as specified and directedby Engineer-in-Charge.
110S&F in replacement of wall mounting slim 18/20 Watt 4 feet led Batten luminaire , white with engineering plastic batten with white acrylic cover sleek design & high efficiency for wall and surface mounted applicationscomplete all as specified and directedby Engineer-in-Charge.
111S&F in replacement of wall mountingLED slim 9/10 Watt 2 feet, white with high efficient LEDs & glare free opal diffuser complete all as specified and directedby Engineer-in-Charge.
112S & F in replacement enviroment friendly recess/surface mounting LED flat panel 2"x2", cool white with high efficient LEDs & glare free opal diffuser (36 W) PF>0.95 driver life >25000 Hours, operating range 140v to 280 V includingcomplete all as specified and directedby Engineer-in-Charge.
113S& F LED fitting bulkhead 10 Watt single phase 50 Hz IP 66 outdoor type complete all as specified and directedby Engineer-in-Charge.
114S&F in replacement of Recesses mountingLED slim round downlighter 12 Watt warmwhite with high efficient LEDs & glare free opal diffuser complete all as specified and directedby Engineer-in-Charge.
115S&F in replacement of Recesses mountingLED slim square downlighter 12 Watt warmwhite with high efficient LEDs & glare free opal diffuser complete all as specified and directedby Engineer-in-Charge.
116S&F in replacement MCB SP 5 to 32 Amps,240 volts curve "C",breaking capacity 10KA,complete all as specified and directedby Engineer-in-Charge.
117S&F in replacement MCB SPN32 to 63 Amps,240 volts,curve "C", breaking capacity 10 KA,complete all as specified and directedby Engineer-in-Charge.
118S&F in replacement MCB TP 40 to 63 Amps,415 volts curve "C",breaking capacity 10KA, complete all as specified and directedby Engineer-in-Charge.
119S&F in replacement MCB TPN 40 Amps,415 volts curve "C",breaking capacity 10KA,complete all as specified and directedby Engineer-in-Charge.
120S&F in replacement MCB TPN 63 Amps,415 volts curve "C",breaking capacity 10KA,complete all as specified and directedby Engineer-in-Charge.
121S&F in replacement MCB 4 Pole 100 Amps,415 volts curve "C",breaking capacity 10KA, complete all as specified and directedby Engineer-in-Charge.
122S&F in replacement MCCB,Four pole,415 volts, 125 Amps , curve "C",breaking capacity 10 KA,complete all as specified and directedby Engineer-in-Charge.Make : Havells/legrand/l&T
123S&F sheet metal enclosuresDBDouble door Verticle distribution type,04 way,TPN DB , IP43, 415V & suitable for MCCB TP as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and directedby Engineer-in-Charge.
124S&F sheet metal enclosuresDBDouble doordistribution type,04 way,TPN DB , IP43, 415V & suitable for MCB TP as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and directedby Engineer-in-Charge.
125S&F sheet metal enclosuresDBDouble doordistribution type,06 way,TPN DB , IP43, 415V & suitable for MCB TP as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and directedby Engineer-in-Charge.
126S&F in replacement sheet metal enclosuresDBDouble door type 8 way SPN 240 voltincluding 200 Amps rated bus bar with neutral link complete all as specified and directedby Engineer-in-Charge.
127S&F in replacement sheet metal enclosuresDBDouble door type 4 way SPN 240 voltincluding 200 Amps rated bus bar with neutral link complete all as specified and directedby Engineer-in-Charge.
128S&F for ceiling rose surface bakelite 65x50mm two to three terminals complete all as specified and as directed by Engr-in-Charge.
129S& F in repair casing capping of size 15 mmto cover the copper conductor in wall complete all as specified and directedby Engineer-in-Charge.
130S&F in replacement of LED electronic driver suitable for 20 Watt LED batten fitting complete all as specified and directedby Engineer-in-Charge.
131S&F in replacement of LED electronic driver suitable for 36 Watt LED (2"x2") recesses mountedfitting complete all as specified and directedby Engineer-in-Charge.
132Supply and fix external wall mounted switch board 15 Amps consisting of one number 15 Amps switch and socket including frame and sheet complete with screws complete all as specified and directedby Engineer-in-Charge.
133Supply and fix external wall mounted switch board 5 Amps consisting of one number 5 Amps switch and socket including frame and sheet complete with screws al as specified and as directed by Engineer-in-charge.
134Taking down pressure pump motor of capacity upto 1 HP, single phase , 230 Volt complete all as specified and directedby Engineer-in-Charge.
135M&L for rewinding of presume pump motor of capacity upto 1 HP single phase , 230 Volt complete all as specified and directedby Engineer-in-Charge.
136M&L for refixing presume pump motor of capacity upto 1 HP single phase , 230 Volt all as per specified and as directed by Engineer-in-charge.
137M&L earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand includinggalvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means ofnuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dollyall as shown in electrical plate No 3 of MES SSR part I and testing on completion includingnecessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc complete all as specified and directedby Engineer-in-Charge.
138Supply only ISI marked self adhesive PVC electrical insulation Tape roll of 25 mm wide,0.125 mm thick and 25 RM lengthcomplete all as specified and directedby Engineer-in-Charge.
139Taking down carefully water heater storage type 25 ltrs/50 Ltrs capacity for repair and over hauling and opening to geysers and comprising of heating element thermo stat switch, electric connection cleaning and descaling with descaling solution the geysers tank and checking of leakage on pressure at 150 PSI and testing for smooth functioning complete all as specified and directedby Engineer-in-Charge.
140S&F in replacement of heating element 2.00 KW capacity 230 volt suitable for geysers any type as per site requirement ISI mark complete all as specified and directed by Engineer-in-Charge
141All as per item No 140 above but 1.5 KW capacity 230 volt complete all as specified and directedby Engineer-in-Charge.
142S&F in replacement thermostat switch connection any type suitable for geyser of any size/model complete all as specified and directed by Engineer-in-charge.
143S&F in replacement of geyser assembly any make any type for 25 ltrs/50 ltrs capacity water heater including replacement of rubber seal complete all as specified and directed by Engineer-in-Charge.
144Supply and fixing in replacement of indicator lamp (Pilot type)for 25 ltrs water heater complete all as specified and directed by Engineer-in-Charge. Make : As per ISI Marked.
145Supply and fixing in replacement of PVC insulated copper conductor cable 4 Sqmm size 3 core grade (For Geyser) complete all as specified and directed by Engineer-in-Charge. Make: Kalinga/Plaza/Finolex.
146S&F in replacement of water storage tank of suitable for 25ltrs capacity incl glass wool complete all as specified and directed by Engineer-in-Charge.
147S&F in replacement of water storage tank of suitable for 50ltrs capacity incl glass wool complete all as specified and directed by Engineer-in-Charge.
148Supply & fixing in replacement ofbottom cover suitable cylindrical type geyser for 25 Ltrs/ 50 Ltrscapacity geyser all as specified and directed by Engineer-in-Charge
149All as per item No 148 above but of capacity 50 Ltrscomplete all as specified and directedby Engineer-in-Charge.
150M&L for preparation of external surface of geyser body 25 ltrs rubbing the rusted surface and painting with two coats of spray paint with synthetic enamel paint over a coat of metal primer matching with existing colour complete all as specified and directedby Engineer-in-Charge.
151S& F heavy duty PVC pipe suitable for hot water flow for geysers of capcity 25 to 50 ltrs all as specified and as directed by Engineer-in-Charge
152S& F plug top 3 pin ,15 Amps rating all as specified and as directed by Engineer-in-Charge
153S& F plug top 3 pin ,5 Amps rating all as specified and as directed by Engineer-in-Charge
154Supply and install in replacement AC Box with plug and socket complete with 16 to 32 Amp SP MCB C Curve 10 KA complete all as specified and directed by Engineer-in-Charge.
155S&F in repair wall mounted TPN busbar chamber factory made with busbar of current rating 400 Amp, 415 Volts complete all as specified and directed by Engineer-in-Charge.
156Supply and fixing in replacement of capacitor of following sizes complete all as specified and directed by Engineer-in-Charge. (a).2.5 Mfd.
157All as per item No 156 above but 3.15 Mfd complete all as specified and directed by Engineer-in-Charge.
158M&L for rewinding of burnt fan1200 mm/1400 mm sweepwith super enameled copper wire winding, rubber real, U’ clamps, nuts, bolts, washers and split pins of suitable size as per details of any make/model complete all as specified and directed by Engineer-in-Charge.
159Taking down ceiling fan 1200 mm/1400 mm sweep removing cleaning of dust, properly cleaning and greasing of bearing and connecting up complete all as specified and directed by Engineer-in-Charge.
160Supply in replacement for rewinding of exhaust fan as per details given below with supper enameled copper wireof suitable size of any make/type/model including transportation complete all as specified and directed by Engineer-in-Charge :-(a) Exhaust fan 300mm (12’size)
161All as per item No 160 above but Exhaust fan 380mm (15” size) complete all as specified and directed by Engineer-in-Charge.
162Supply in replacementfor exhaust fan Louver of following size complete all as specified and directed by Engineer-in-Charge (a) 380 mm
163All as per item No 162 above 300 mm complete all as specified and directed by Engineer-in-Charge
164Taking down carefully defective wall mounted fan of any size and make and oiling greasing after opening and refixing the fan to its position after repair and testing complete all as specified and directed by Engineer-in-Charge.(a)Wall fan of size 400mm
165All as per item No 164 above Wall fan of size 300mm complete all as specified and directed by Engineer-in-Charge
166M&L for rewinding of wall mounted fan given below with super enameled copper wire Including of suitable of size of any make/type model complete all as specified and directed by Engineer –in-charge :- (a)Wall fan of size 400mm
167All as per item No 166 above Wall fan of size 300mm complete all as specified and directed by Engineer-in-Charge
168Supply and fixing in replacementventilating fan plastic 250 mm sweepbody 240 v 50 Hz single phase complete all as specified and directed by Engineer-in-Charge
169Supply and fixing in replacementventilating fan plastic 300 mm sweepbody 240 v 50 Hz single phase all as specified and directed by Engineer-in-charge.
170Supply and fixing in replacement wall mounted fan plastic body 240 v single phase 50 Hz complete all as specified and directed by Engineer-in-Charge
171S&F in replacement for wall mounted fan bushes ,shaft and suitable body cover ,moving partcomplete all as specified and directed by Engineer-in-Charge
172Supply only ISI marked self adhesive PVC electrical insulation Tape roll of 25 mm wide,0.125 mm thick and 25 RM lengthcomplete all as specified and directed by Engineer-in-Charge
173S&F decorative 45 W LED Strip light including drivers and necessary connections non-integral flexible type with high brihtness for indoor and outdoor applications. Strip can be cut at marked interval to suit desired length complete all as specified and directed by Engineer-in-Charge
174M&L submain wiring with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked25mm dia as per IS specification fixed concealedin wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length)
175M&L submain wiring with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked25mm dia as per IS specification fixed concealedin wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 6 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed by Engineer-in-Charge Note : Two runs of 6 sqmm cable alongwith one run of 6 Sqmm PVC insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length).
176Supply and fixing in replacement of PVC insulated copper conductor cable 1.5 Sqmm size 3 core gradecomplete all as specified and directed by Engineer-in-Charge. Make: Kalinga/Plaza/Finolex.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail