}

Tender For Repairs / Replacement Of Ceiling Fan / Exhaust Fan / Wall Fan / Pedestal Fan / Air Circulator Fan, Geyser ,Solar Water Heater At Main Camp At Af Station Tambaram, tambaram-Tamil Nadu

Military Engineer Services-MES has published Tender For Repairs / Replacement Of Ceiling Fan / Exhaust Fan / Wall Fan / Pedestal Fan / Air Circulator Fan, Geyser ,Solar Water Heater At Main Camp At Af Station Tambaram. Submission Date for this Tender is 22-06-2023. Solar Heater Tenders in tambaram Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

37779324
Corrigendum : Tender For Repairs / Replacement Of Ceiling Fan / Exhaust Fan / Wall Fan / Pedestal Fan / Air Circulator Fan, Geyser ,Solar Water Heater At Main Camp At Af Station Tambaram
Open Tender
Indian
Tamil Nadu
tambaram
22-06-2023

Tender Details

Repairs / Replacement Of Ceiling Fan / Exhaust Fan / Wall Fan / Pedestal Fan / Air Circulator Fan, Geyser ,Solar Water Heater At Main Camp At Af Station Tambaram

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-06-2023
2 17-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 64000.0 /-
Tender Value
INR 32 Lakhs /-

BOQ Items

Name of Work:REPAIRS / REPLACEMENT OFCEILING FAN / EXHAUST FAN / WALL FAN / PEDESTAL FAN / AIR CIRCULATORFAN, GEYSER ,SOLAR WATER HEATER AT MAIN CAMP AT AF STATIONTAMBARAM
Sl. No. Item Description
1Taking down carefully the ceiling fan including BLDC fan/exhaust fan/wall Mounted fan/pedestal fan / Aircirculator fan of any size/ Make after disconnecting the electrical connection etc.all as specified and directed
2Refixing/Instal only ceiling fan any size/make replacing the spares such as carterpin Unserviceable/Rusted nut bolts,split pin rubber wheel bearing washers,bush,PVC clamps for holdings of capacitor etc.And connectingup with PVC insulated cable size 1.5 Sqmm three core copper conductor round cable complete all as Specified (Note:-Rewinding,spare parts suchas ball bearing, capacitor,bush etc required to make the ceiling fan serviceable shall be measured paid seperately under relevent items..The Refixing fan shall be tested after fixing the blades)
3Refixing /Instal only Exhaust/Pedestal/Wall Mounted fans along with louvers any description any approval make,replacing the spares such as carter pin Unserviceable /Rusted nut bolts,split pin rubber wheel bearing washers,bush,PVC clamps for holdings of capacitor etc.And connectingup with PVC insulated cable size 1.5 Sqmm three core copper conductor round cable complete all as Specified (Note:-Rewinding,spare parts suchas ball bearing, capacitor,bush etc required to make the Exhaust/ Pedestal/ Wall mounted fansserviceable shall be measured paid seperately under relevent items..The Refixing fan shall be tested after fixing the blades)
4Material and labour for rewinding of fan motor with super enameled copper winding wire of same gauge and weight after cutting and removeing the existing burnt/heated up windings,including cleaning of rotor and varnishing,heating and providing fresh insulating Materials for the following size of fans/circulators :-( a ) Exhaust fan225 to 300 mm Sweep.
5(b) Exhaust Fan 350 to 450mmSweep
6(c) Pedestal fan 400mm to 600mm sweep
7(d) Wallmounted fan 400mm sweep
8(e) Ceiling fan of 1200 mm sweep
9(f )Ceiling fan of 1400 mm sweep
10(g )Air circulatorfan of450mm to 600 mm sweep
11Supply onlyball bearing size (6201/6202/6203) suitablefor ceiling fans size 1200/1400 mm Sweep complete all as specified and as directed.
12Supply onlyball bearing Size (2001/2002/2003) suitablefor exhaust/wallfan/pedestal fan of any size and make complete all as specified and as directed.
13Supply only capcitor of capacity 2.5 mfd for the fans in position as directed by Engineer -in-Charge.
14Supply only capcitor of capacity 4 mfd for the fans in position as directed by Engineer -in-Charge.
15Supply only GM bush suitable for ceiling fan of size 1200/1400 mm Sweep
16Supply onlybush suitable for exhaust fans any make/size
17Supply only ceiling fan canopy / cup white in colorsuitable for all types ofceiling fans
18Supply and fix in repairexhaust fan louvers size (450/300/275/230)suitable for Exhaust fanall as specified and as direcetd.
19Supply only exhaust fan blades suitable for (450/300/275/230) suitable exhaust fan all as specified and as directed.
20Supply onlyPCB board convertible 240 Volt ACto 12 Volt DCsuitable for BLDC ceiling fan any type/ model of ceiling fan 1200 mm sweep230 Volt 50 Hzall as specified and as directed .
21Material & labour for Cleaning and preparing the surface of ceiling fan of any sweep, removing the grease,carbon dust over the fans,filling cavities with filler and applying one coat synthetic enamel paintpainting of ceiling fanwith down rod upto 2.00 mtr long with two coats of synthetic enamel white paint of approved colour bysprayingincluding preparation of old painted surface & writing of MES No on the fancomplete all as specified and as directed.
22Material & labour for Cleaning and preparing the surface of exhaust /wall mounted /pedestal/Air circulatedany sweep, removing the grease,carbon dust over the fans,filling cavities with filler and applying exisitingcolour bysynthetic enamel paint of approved colour bysprayingincludingwriting of MES No on the fancomplete all as specified and as directed.
23Taking down carefully storage type water heater (Geyser)of any type and make up to 25 /50 Ltrs capacity after disconnecting all Electrical connecting,descaling the inner container heating element base assembly etc by using diluted hydrochloric acid and cleanning thoroughly,filling the inner container with water and checking leakage if any reasembling the geyser after of leakage by bracing and electric and water supply lines,refixing and testing on completion all as specified and directed (Note:-spares shall be measured and paid seperately under relevent items of this Schedule)
24Supply and fix in repair of following spares for the geysers and testing the same as directed :- ( a) Heating Elements with rubbergasket thread/push type 230V,2.0 KW (Make:-Bajaj/Usha/Racold)
25Supply and fix Thermostart suitable for Geysers 25 to 50 Ltrs capasity,and temp range 30 to 80 degree centigrade and cut off at 70 degree centigrade all as specified and as directed.
26Supply and fix in replacement white cableswater heater indicator red /greenlamp completeall as specified and directed.
27Supply and fix in replacement 3 pin plug top 16 Amp all as specified and directed.
28Supply and fix PVC Connecting pipe 15 mm dia 450 mm long heavy duty suitable for hot/cold water with two brass union and washers completed all as directed.
29Supply and fix in replacement of solar water tank capacity220 Lpd FPC inner tank 3mm thickness Galvanized steel enamel coated,and outer cladding with 50 mm thickPUF,outer claddingmade with pre-coated laminated sheet (color-Half white)with support structure standmade of galvanized steel with powder coating and all requireplumbing work,including commisioning, testing,complete all included in quoted rate allas specified and as direcetd.
30Supply andfix in replacement of solar water heater FPC panelssize 2000mm x1000mm and capasity for 220 ltr for -02 solar FPC panels with stand with following :-section-1.2 mm thick aluminium,Back sheet -0.46mm thick Aluminium,insulation -fiber Glass wool,,foil- 0.05 mm thick Aluminium,Flat Plate collector fins(9 Nos )-Ultrasonic welded with Nalsum coating,copper pipe 24 SWG ,Aluminium,Headed Pipe -copper 24 SWG,Glazing - 1000* 2000* 4 mm clear toughned glass & 960 * 1660*4,glass bleedingE.P.D.MRubber,fasteners-stainless steel ,Grommets -EP,D,M Rubber,flanges -brass,all as finished with power coating withinstallation, testing and commisioningall as specified and as directed.
31Material and labour for serviceing the solar water heater any make/type/capacity,cleanning/descalling of solar collecting panel of copper pins/tubes including replaceing the sacrifical anode rod and panel tuffen glass 4 mm thick (size2mx1m) completed all as specified and as directed.
32Taking down carefullyAir Curtain fansize 3 feet , 230 Volt 50 Hz any size/make forrepair/replacing thewinding, nut bolts,bearing washers,bush,PVC clamps for holdings of capacitor, etc.And connectingup with PVC insulated cable size 1.5 Sqmm three core copper conductor cable complete all as Specified (Note:-Rewinding and spare parts suchas ball bearing, capacitor,bush etc required to make Serviceableand Refixing the above said all items are inclusive of Quoted rate all as specified and as direcetd.
33Supply and fix in repair ceiling fan down rod size 10" to 18" inches fabricated out of 15 mm dia GI pipe medium grade duly cutting/threading /drilling etc.suitable for check nuts and split pin including Uclamp bolts,nuts,washers,rubber split pin check nutsetc suitable for ceiling fan 1200/1400 mm sweep incl taking down of unserviceable complete all as specified.
34Supply and fix in repair ceiling fan hook made out of MS flat iron 40x6 mm dia bar bend to shape for hanging ceiling fan incl taking down unserviceable complete all as specified.
35Supply and fix in repair regulator electronic type with control suitable for 1200/1400 mmsweep ceiling fan all as specified.
36M&L for sub main wiring with 2 runs of 4 Sqmmsingle core FRLS PVC insulated unsheated cable 1100 volts grade with multistranded copper conductor drawn through in existing surface/recessed steel/pvc conduit and accessories on surface of wall roof etc with one run of 4.0 sqmm of PVC FRLS copper cable for earth continuity all as specified.dismantlingexisting sub main wiring and making good distrubed portion complete all as specified and as directed
37All as per item No36 here in befire but with 2x6.0 sqmm along with 1x6.0 sqmm as earth continuty conductor.
38All as per item No36here in befire but with 2x10.0 sqmm along with 1x10.0 sqmm as earth continuty conductor.(Note:-for ser No 36 to 38 : Two runs of cable and one run of earth continuty cable shall bemeasured as one unit.)
39Supply and fix in replacementMCB SP 6to 32Amps,10KA 240 volts,50 Hz.all as specified and as directed by engineer-in Charge.
40Supply anf fix in replacement Single pole and Neutral Encloser with two pin and earth plug and Metal glad Socket Complete with one Single Pole MCB 20/32 Amps 240Volt all as specified and as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail