Tender For Special Repairs To Basketball Court (P/113) Near Mt Pool At Ins Mandovi Under Ge (P) Navy Mandovi, North Goa-Goa

Military Engineer Services-MES has published Tender For Special Repairs To Basketball Court (P/113) Near Mt Pool At Ins Mandovi Under Ge (P) Navy Mandovi. Submission Date for this Tender is 22-06-2023. Construction Material Tenders in North Goa Goa. Bidders can get complete Tender details and download the document.




Tender Notice

37778958
Corrigendum : Tender For Special Repairs To Basketball Court (P/113) Near Mt Pool At Ins Mandovi Under Ge (P) Navy Mandovi
Open Tender
Indian
Goa
North Goa
22-06-2023

Tender Details

Special Repairs To Basketball Court ( P / 113 ) Near Mt Pool At Ins Mandovi Under Ge ( P ) Navy Mandovi 1 B / R Portion 2 Demolition Of Cement Concrete ( Unreinforced ) Of Any Description And In Any Position Not Otherwise Specifically Provided For Complete All As Specified And Directed. 3 M & L For Providing 7.5 Cm Thick ( Compacted Thickness ) Wbm, With Granite, Trap Or Basalt Coarse Aggregates Of Grading 2 ( 63 To 40 Mm Size ) Or Of Grading 3 ( 50 To 20 Mm Size ) , Spread, Rolled And Consolidated To Gradient And Camber Required Complete All As Specified And Directed. 4 M & L For Preparing Black Top Surface By Brushing With Wire Brushes For Removing Caked Mud Etc, Sweeping With Brooms And Finally Fanning The Cleaning Surface With Gunny Bags To Remove All Loose Dirt Etc. Complete All As Specified And Directed. 5 M & L For Applying Evenly A Priming / Tack Coat With Paving Bituminous Primer At 5 Kg Per 10 Sqm Complete All As Specified And Directed. 6 M & L For Providing Bituminous Premix Asphaltic Semi Dense Concrete Carpet Of 20 Mm Consolidated Thickness, Using 20Mm And 12Mm Size Stone Chipping Mixed With 3.5% Binder Content ( Paving Bitumen, Any Penetration ) By Weight Of Total Mix Laid With Mechanical Paver, Rolled And Compacted To Required Camber And Gradient Using Paver Roller Exc 6 Tonne And N. Exc 12 Tonne Complete All As Specified And Directed. 7 M & L For Providing Bituminous Premix Asphaltic Semi Dense Concrete Carpet Of 20 Mm Consolidated Thickness, Using 6Mm And 4Mm Size Stone Chipping Mixed With 4.0% Binder Content ( Paving Bitumen, Any Penetration ) By Weight Of Total Mix Laid With Mechanical Paver, Rolled And Compacted To Required Camber And Gradient Using Paver Roller Exc 6 Tonne And N. Exc 12 Tonne Complete All As Specified And Directed. 8 M & L For Preparation Of The Court In Following Steps Complete All As Specified And Directed: ( A ) Pressure Washing The Court To Remove Built-Up Moss. ( B ) Scrubing The Area With Machine To Even Out The Surface And Prepare For Smooth Application Of Layering ( C ) Pressure Washing The Entire Court Again. 9 M & L For Applying All Weather Proof Acrylic Synthetic Itf Certified Surface To Existing Court In Following Layers As Per Manufacturer Insutructions Complete All As Specified And Directed: ( A ) Applying First Coat Of Primer. ( B ) Applying Second Coat Of Resurfacer ( C ) Applying Third Coat Of Resurfacer ( D ) Applying Fourth Layer Of Synthetic Paint ( E ) Applying Fifth Layer Of Synthetic Paint ( F ) Line Marking As Per International Standard. Notes: ( I ) The Work Shall Be Carried Out Through An External Specialist Agency Having Suitable Experience In Carrying Out Similar Works. ( Ii ) Contractor Shall Submit Necesary Guarantee / Warranty Certificate To The Engineer-In-Charge. 10 S & F Basketball Post Of Tempered Acrylic Back Board Of 20 Mm In Aluminium Frame With Ring And Net Including All Fittings Complete All As Specified And Directed. 11 Dismantling Fencing Wire Mesh, Any Type Complete All As Specified And Directed. 12 Dismantling Steel Post Or Struts, Any Section, Embedded In Concrete / Brick Work / Masonry Including Taking Out Embedded Portion And Making Good Disturbed Ground Complete All As Specified And Directed. 13 S & F Mild Steel For Posts And Struts In Fencing Including Cutting Tops To Shape As Directed, Drilling Holes, Notching For Wire, Etc.; Flat Iron Fillets ( For Securing Wire Mesh Etc. ) Including All Necessary Drilling, Bolting Or Riveting, Etc., And Similar Work Conforming To Fe-290 Gde E-165 Complete All As Specified And Directed. 14 S & F Mild Steel Screw Bolts ( Machine Made ) With Hexagonal Or Square Heads At One End And Screwed The Other, Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut, Length Of Bolt Exc 5Cm But N Exc 10Cm Long And Diameter Of Neck 5 To 10 Mm Complete All As Specified And Directed. 15 M & L For Providing Tmt Bars Mild Steel Bars 10 Mm Dia, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clips For Stiffner Of Chainlink Fencing Complete All As Specified And Directed. 16 Supply Only Chain Link Fencing With 3Mm Dia Galvanised Steel Wire, Size Of Mesh 75Mm X 75Mm, Weight Exc 2.0 Kg Per Sqm But N.Exc 2.50 Kg Per Sqm Complete All As Specified And Directed. 17 Fixing Only Chain Link Fencing Including Line Wires, Any Mesh, Size And Type To Any Type Of Standards, Rails, Straining Bolts Etc Including Provision Of Binding Wire Complete All As Specified And Directed. 18 M & L For Providing Cement Concrete 1:2:4, Type B2, Using 40Mm Graded Aggregate As In Walls Or Retaining Walls, Any Thickness, Size Or Shape Including Pilasters, Buttresses Columns, Pillars, Boundary Pillars And Posts ( Including Caps And Bases ) Complete All As Specified And Directed. 19 Demolition Of Brickwork Or Stone / Boulder Masonry, Built In Cement Mortar For Ashlar Facings, Dressed Stonework And Precast Concrete Articles Complete All As Specified And Directed. 20 M & L For Pre-Cast Cement Concrete Block Masony With Solid Blocks Of Precast Cement Concrete 1:3:6 Type C1 ( Using 20 Mm Graded Stone Aggregate ) , Exc 10Cm In Width And Set In Cement Mortar 1:6 Complete All As Specified And Directed. 21 M & L For Rendering 10 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar 1:6, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 22 M & L For Preparation Of New Or Previously Untreated Steel Surfaces Of Any Description, Over 10 Cm In Width Or Girth, Not Otherwise Described And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Complete All As Specified And Directed. 23 M & L For Preperation Of Old Plastered Wall Surfaces And Applying Two Coats Of White Wash Complete All As Specified And Directed. 24 External Electric Supply 25 Taking Down Old U / S Damaged Gi / Rcc Pole Including All Fittings Complete All As Specified And Directed. 26 Taking Down Old U / S Lt Panel Of Any Type Complete All As Specified And Directed. 27 Taking Down Old U / S Lt Ug Cable Of Any Size And Make Complete All As Specified And Directed. 28 S & F Hot Dip Galvanised Iron, Octogonal Pole, Of Height 7 Mtrs, Minimum Galvanising Of 70 Microns, Top 70 Mm, Bottom 130 Mm And 3 Mm Sheet Thickness In Single Section, Without Any Weld Joints, With Square Plate Of Minimum Dimensions 225 X 225 X 12 Mm Foundation Bolts, Single Arm Gi Bracket Of 900 X 1000 Mm For Mounting One Or Two Light Fittings, Backelite Sheet With One 6 A Sp Mcb And 16 Mm Stud Type Connectors - 04 Nos Inside The Pole At The Door Opening For Cable Connections, Common Templates Minimum 01 For Each 15 Poles All Fixed And Bolted On And Including Suitable Pcc Pedestal As Per Manufacturers Recommendations And Specifications For Street / Security Lights Complete All As Specified And Directed. Note: Mast And Pole Shaft Shall Be As Per Bsen 10025, Is 5986, Astm A572. Make Of Pole: Bajaj / Jindal / Crompton / Shubham Or Equivalent 29 S & F In Repairs Led Area Flood Light Fitting, 250 Watt, For 230 V 50Hz Ac Supply, Energy Saving Environmental Friendly, Long Life, Energy Saving Environmental Friendly, Long Life, Housed In Exclusive Innovative Die Cast Aluminium Housing Confirming To Ip 66, Suitable For Highlighting Architectural Features Or Retail Spaces And Connecting To Mcb With 2.5 Sqmm 3 Core Copper Cable Multistranded Conductor Complete All As Specified And Directed. 30 Supplying, Laying, Jointing, Testing And Commissioning Of Lt Xlpe Insulated, Armoured, Heavy Duty Electric Cables With Multistranded Aluminium Conductor Of 4 Core, 25 Sqmm, Shielded Core Type Wrapped With Tape Screwed Galvanized Strip, Suitable For Earthed System For 1100V, Ac 50 Cycle Including Centre Glands, Lugs, Jointing Materials Etc Complete All As Specified And Directed. Note: Excavation, Pcc, Covers And Protection Shall Be Measured And Paid Separately Under Relevant Items Of This Schedule. 31 Supplying, Laying, Jointing, Testing And Commissioning Of Lt Xlpe Insulated, Armoured, Heavy Duty Electric Cables With Multistranded Aluminium Conductor Of 4 Core, 10 Sqmm, Shielded Core Type Wrapped With Tape Screwed Galvanized Strip, Suitable For Earthed System For 1100V, Ac 50 Cycle Including Centre Glands, Lugs, Jointing Materials Etc Complete All As Specified And Directed. Note: Excavation, Pcc, Covers And Protection Shall Be Measured And Paid Separately Under Relevant Items Of This Schedule. 32 Excavation In Trenches, N Exc 1.5 M Wide And N Exc 1.5 M In Depth; For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. N Exc 10 Sq M On Plan And N Exc 1.5 M In Depth And Getting Out In Soft / Disintegrated Rock Complete All As Specified And Directed. 33 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25 Cm Thick Using Excavated Soft Disintegrated Rock Complete All As Specified And Directed. 34 Removing Excavated Material To A Distance N Exc. 50M And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point Complete All As Specified And Directed. 35 Supply And Laying Fine Dry River Sand For Cable Protection In Trenches For Cable Protection Complete All As Specified And Directed. Note : Punned Thickness Only Will Be Measured & Paid. 36 Supplying And Laying Un-Reinforced Precast Concrete Cable Cover For Cable Protection, Class Lv, Type I, Flat, Size 250Mm X 150Mm X 40Mm, Isi Marked Complete All As Specified And Directed. 37 Supply And Laying 40Mm Dia Bore Light Grade Gi Tubing In Trenches / On Pole / Road Crossing For Cable Protection Complete All As Specified And Directed. 38 M & L For Providing Cement Concrete 1:3:6 Type C2 Using 40Mm Graded Aggregate As In Foundations, Filling And Mass Concrete Complete All As Specified And Directed. 39 Supply, Installing, Testing And Commissioning Of Lt Panel Board, Cpri Approved, Made Out Of 3.15Mm Thick Crca Sheet, Outdoor Type, Front And Rear Opening Totally Enclosed In Dust, Weather And Vermin Proof Casing, With Minimum 60 Cm Depth Of Panel, Having Copper Bus Bar Of Capacity 200 Amps, For 50 Hz Ac Supply, Ryb N Insulated Busbars With Suitable Insulator And Including Multifuntional Digital Type Panel Meter Including Ct Ratio, Selector Switches, Indicator Lamps, Internal Wiring, Powder Coated Cabinets For Housing Accessories As Mentioned Below; Entire Panel Mounted On Suitable Angle Iron Frame 50 Cm Above Ground And Providing Glands For Each Incoming And Outgoing Cables Including Necessary Excavation And Pcc Work Complete All As Specified And Directed :- Incoming:- ( A ) Mccb 100 Amps 4-Pole 415 Volts, Breaking Capacity 16 Ka Of Rating - 01 No ( B ) Copper 4-Pole Busbar 200 Amps - 1 Set Outgoing:- ( A ) Mcb Spn 240 Volts, C Series, Breaking Capacity 10 Ka Of Rating 32 Amps - 5 No ( B ) Digital Voltmeter, With Connected Wiring Accessories - 01 Set ( C ) Digital Ammeter, With Cts & Connected Accessories - 01 Set ( D ) Led Phase Indication Lamps Ryb - 01 Set ( E ) Analog Timer Switch 3 Module With Wiring And Connections 40 M & L For Earthing Complete With Galvanised Steel Earth Plate Electrode 60Cm X 60Cm X 6 Mm Thick Buried Directly In Ground, Earth Pit Not Less Than 2.25 M Below Ground Level, With Top Edge Of Plate Not Less Than 1.5 M Below Ground Level, Connected To 4Mm Dia Gi Earth Wire By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Steel Including Neccessary Earthwork And Excavation In Any Strata, Pcc Chamber In Pcc 1:3:6 Type C2, 20 Mm Dia Light Grade Gi Pipe For Protection Of Earth Strip And Gi Wire, Chamber Cover Etc All As Per Electrical Plate No. 3 Of Ssr Part-I Including Connections With Earth Testing Point Complete All As Specified And Directed. Note: On Testing After Completion If The Desired Earth Resistance Is Not Obtained, Earthing Shall Be Redone At No Extra Cost. 41 M & L For Providing Earth Continuity Conductor Or Main Earthing Lead, 4 Mm Dia Galvanised Iron Or Steel Wire, Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit / Pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required Complete All As Specified And Directed. 42 M & L For Earthing Complete With Galvanised Steel Earth Plate Electrode 60Cm X 60Cm X 6 Mm Thick Buried Directly In Ground, Earth Pit Not Less Than 2.25 M Below Ground Level, With Top Edge Of Plate Not Less Than 1.5 M Below Ground Level, Connected To 32 X 6 Mm Gi Earth Strip By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Steel Including Neccessary Earthwork And Excavation In Any Strata, Pcc Chamber In Pcc 1:3:6 Type C2, 20 Mm Dia Light Grade Gi Pipe For Protection Of Earth Strip And Gi Wire, Chamber Cover Etc All As Per Electrical Plate No. 3 Of Ssr Part-I Including Connections With Earth Testing Point Complete All As Specified And Directed. Note: On Testing After Completion If The Desired Earth Resistance Is Not Obtained, Earthing Shall Be Redone At No Extra Cost.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 63400.0 /-
Tender Value
INR 31.70 Lakhs /-

BOQ Items

Name of Work:
Sl. No. Item Description
1B/R PORTION
2Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
3M & L for providing 7.5 cm thick (compacted thickness) WBM, with granite, trap or basalt coarse aggregates of grading 2 (63 to 40 mm size) or of grading 3 (50 to 20 mm size), spread, rolled and consolidated to gradient and camber required complete all as specified and directed.
4M & L for preparing black top surface by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaning surface with gunny bags to remove all loose dirt etc. complete all as specified and directed.
5M & L for applying evenly a priming/ tack coat with paving bituminous primer at 5 kg per 10 Sqm complete all as specified and directed.
6M & L for providing bituminous premix asphaltic semi dense concrete carpet of 20 mm consolidated thickness, using 20mm and 12mm size stone chipping mixed with 3.5% binder content (paving bitumen, any penetration) by weight of total mix laid with mechanical paver, rolled and compacted to required camber and gradient using paver roller exc 6 tonne and n. exc 12 tonne complete all as specified and directed.
7M & L for providing bituminous premix asphaltic semi dense concrete carpet of 20 mm consolidated thickness, using 6mm and 4mm size stone chipping mixed with 4.0% binder content (paving bitumen, any penetration) by weight of total mix laid with mechanical paver, rolled and compacted to required camber and gradient using paver roller exc 6 tonne and n. exc 12 tonne complete all as specified and directed.
8M & L for preparation of the court in following steps complete all as specified and directed: (a) Pressure washing the court to remove built-up moss. (b) Scrubing the area with machine to even out the surface and prepare for smooth application of layering (c) Pressure washing the entire court again.
9M & L for applying all weather proof acrylic synthetic ITF certified surface to existing court in following layers as per Manufacturer insutructions complete all as specified and directed: (a) Applying first coat of primer. (b) Applying second coat of resurfacer (c) Applying third coat of resurfacer (d) Applying fourth layer of synthetic paint (e) Applying fifth layer of synthetic paint (f) Line marking as per International standard. Notes: (i) The work shall be carried out through an external specialist agency having suitable experience in carrying out similar works. (ii) Contractor shall submit necesary guarantee/ warranty certificate to the Engineer-in-Charge.
10S & F basketball post of tempered acrylic back board of 20 mm in aluminium frame with ring and net including all fittings complete all as specified and directed.
11Dismantling fencing wire mesh, any type complete all as specified and directed.
12Dismantling steel post or struts, any section, embedded in concrete/ brick work/ masonry including taking out embedded portion and making good disturbed ground complete all as specified and directed.
13S & F mild steel for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
14S & F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm but n exc 10cm long and diameter of neck 5 to 10 mm complete all as specified and directed.
15M & L for providing TMT bars mild steel bars 10 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips for stiffner of chainlink fencing complete all as specified and directed.
16Supply only chain link fencing with 3mm dia galvanised steel wire, size of mesh 75mm x 75mm, weight exc 2.0 kg per sqm but n.exc 2.50 kg per sqm complete all as specified and directed.
17Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc including provision of binding wire complete all as specified and directed.
18M & L for providing cement concrete 1:2:4, type B2, using 40mm graded aggregate as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed.
19Demolition of brickwork or stone/ boulder masonry, built in cement mortar for ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
20M & L for pre-cast cement concrete block masony with solid blocks of precast cement concrete 1:3:6 type C1 (using 20 mm graded stone aggregate), exc 10cm in width and set in cement mortar 1:6 complete all as specified and directed.
21M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed.
22M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
23M & L for preperation of old plastered wall surfaces and applying two coats of white wash complete all as specified and directed.
24EXTERNAL ELECTRIC SUPPLY
25Taking down old u/s damaged GI/ RCC pole including all fittings complete all as specified and directed.
26Taking down old u/s LT panel of any type complete all as specified and directed.
27Taking down old u/s LT UG cable of any size and make complete all as specified and directed.
28S & F hot dip galvanised iron, octogonal pole, of height 7 mtrs, minimum galvanising of 70 microns, top 70 mm, bottom 130 mm and 3 mm sheet thickness in single section, without any weld joints, with square plate of minimum dimensions 225 x 225 x 12 mm foundation bolts, single arm GI bracket of 900 x 1000 mm for mounting one or two light fittings, backelite sheet with one 6 A SP MCB and 16 mm stud type connectors - 04 nos inside the pole at the door opening for cable connections, common templates minimum 01 for each 15 poles all fixed and bolted on and including suitable PCC pedestal as per manufacturers" recommendations and specifications for street/ security lights complete all as specified and directed. Note: Mast and pole shaft shall be as per BSEN 10025, IS 5986, ASTM A572. Make of pole: Bajaj/Jindal/Crompton/Shubham or equivalent
29S & F in repairs LED area flood light fitting, 250 watt, for 230 V 50Hz AC supply, energy saving environmental friendly, long life,energy saving environmental friendly, long life, housed in exclusive innovative die cast aluminium housing confirming to IP 66, suitable for highlighting architectural features or retail spaces and connecting to MCB with 2.5 sqmm 3 core copper cable multistranded conductor complete all as specified and directed.
30Supplying, laying, jointing, testing and commissioning of LT XLPE insulated, armoured, heavy duty electric cables with multistranded aluminium conductor of 4 core, 25 Sqmm, shielded core type wrapped with tape screwed galvanized strip, suitable for earthed system for 1100V, AC 50 cycle including centre glands, lugs, jointing materials etc complete all as specified and directed. Note: Excavation, PCC, covers and protection shall be measured and paid separately under relevant items of this schedule.
31Supplying, laying, jointing, testing and commissioning of LT XLPE insulated, armoured, heavy duty electric cables with multistranded aluminium conductor of 4 core, 10 Sqmm, shielded core type wrapped with tape screwed galvanized strip, suitable for earthed system for 1100V, AC 50 cycle including centre glands, lugs, jointing materials etc complete all as specified and directed. Note: Excavation, PCC, covers and protection shall be measured and paid separately under relevant items of this schedule.
32Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/disintegrated rock complete all as specified and directed.
33Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick using excavated soft disintegrated rock complete all as specified and directed.
34Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
35Supply and laying fine dry river sand for cable protection in trenches for cable protection complete all as specified and directed. Note : Punned thickness only will be measured & paid.
36Supplying and laying un-reinforced precast concrete cable cover for cable protection, class LV, type I, flat, size 250mm x 150mm x 40mm, ISI marked complete all as specified and directed.
37Supply and laying 40mm dia bore light grade GI tubing in trenches/on pole/road crossing for cable protection complete all as specified and directed.
38M & L for providing cement concrete 1:3:6 type C2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and directed.
39Supply, installing, testing and commissioning of LT panel board, CPRI approved, made out of 3.15mm thick CRCA sheet, outdoor type, front and rear opening totally enclosed in dust, weather and vermin proof casing, with minimum 60 cm depth of panel, having copper bus bar of capacity 200 Amps, for 50 Hz AC supply, RYB N insulated busbars with suitable insulator and including multifuntional digital type panel meter including CT ratio, selector switches, indicator lamps, internal wiring, powder coated cabinets for housing accessories as mentioned below; entire panel mounted on suitable angle iron frame 50 cm above ground and providing glands for each incoming and outgoing cables including necessary excavation and PCC work complete all as specified and directed :- INCOMING:- (a) MCCB 100 Amps 4-pole 415 Volts, breaking capacity 16 KA of rating - 01 No (b) Copper 4-pole Busbar 200 Amps - 1 Set OUTGOING:- (a) MCB SPN 240 Volts, "C" series, breaking capacity 10 KA of rating 32 Amps - 5 No (b) Digital voltmeter, with connected wiring accessories - 01 Set (c) Digital Ammeter, with CTs & connected accessories - 01 Set (d) LED Phase indication lamps RYB - 01 set (e) Analog timer switch 3 module with wiring and connections
40M & L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground, earth pit not less than 2.25 m below ground level, with top edge of plate not less than 1.5 m below ground level, connected to 4mm dia GI earth wire by means of bolts, nuts, check nuts and washers of galvanised steel including neccessary earthwork and excavation in any strata, PCC chamber in PCC 1:3:6 type C2, 20 mm dia light grade GI pipe for protection of earth strip and GI wire, chamber cover etc all as per electrical plate No. 3 of SSR Part-I including connections with earth testing pointcomplete all as specified and directed. Note: On testing after completion if the desired earth resistance is not obtained, earthing shall be redone at no extra cost.
41M & L for providing earth continuity conductor or main earthing lead, 4 mm dia galvanised iron or steel wire, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed.
42M & L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground, earth pit not less than 2.25 m below ground level, with top edge of plate not less than 1.5 m below ground level, connected to 32 x 6 mm GI earth strip by means of bolts, nuts, check nuts and washers of galvanised steel including neccessary earthwork and excavation in any strata, PCC chamber in PCC 1:3:6 type C2, 20 mm dia light grade GI pipe for protection of earth strip and GI wire, chamber cover etc all as per electrical plate No. 3 of SSR Part-I including connections with earth testing pointcomplete all as specified and directed. Note: On testing after completion if the desired earth resistance is not obtained, earthing shall be redone at no extra cost.