}

Bids Are Invited For 1 Sub-Head A (Operation And Maintenance)Periodical Operation And Maintenance Of Various Electrical And Mechanical Installations Of Terminal Building, Atc Tower, Fire Station Including Ac Operation, Pump Operation, Fire Fighting An, Varanasi-Uttar Pradesh

Airports Authority Of India has published Bids Are Invited For 1 Sub-Head A (Operation And Maintenance)Periodical Operation And Maintenance Of Various Electrical And Mechanical Installations Of Terminal Building, Atc Tower, Fire Station Including Ac Operation, Pump Operation, Fire Fighting An. Submission Date for this Tender is 10-06-2023. Bearings Tenders in Varanasi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

37760392
Bids Are Invited For 1 Sub-Head A (Operation And Maintenance)Periodical Operation And Maintenance Of Various Electrical And Mechanical Installations Of Terminal Building, Atc Tower, Fire Station Including Ac Operation, Pump Operation, Fire Fighting An
Open Tender
Indian
Uttar Pradesh
Varanasi
10-06-2023

Tender Details

Bids Are Invited For 1 Sub-Head A ( Operation And Maintenance ) Periodical Operation And Maintenance Of Various Electrical And Mechanical Installations Of Terminal Building, Atc Tower, Fire Station Including Ac Operation, Pump Operation, Fire Fighting And Alarm Systems Operation, Glf Operation And Others Including Operation, Repairs And Maintenance, Attending Faults / Breakdown Rectifications, Ensuring Serviceability / Satisfactory Working Conditions Of The System, Attending Complaints, Preventive Maintenance And Maintenance Of Records / Documentation Etc. As Per Detailed Specifications, Terms And Conditions Covered Under This Contract On All Days Including Saturdays, Sundays And Holidays As Per Tender Specifications, Terms And Conditions By Providing Following Manpower As Per Requirement In General Shift Per Day. ( A ) Skilled Manpower-02 Nos. ( Reliever Shall Be Provided On Weekly Off / Holiday ) ( C ) Unskilled Manpower - 02 Nos. ( Reliever Shall Be Provided On Weekly Off / Holiday ) Note-Contractor Has To Provide Reliever On Weekly Offs / Holidays Of Above Required Staffs. 2 Periodical Operation And Maintenance Of Various Electrical And Mechanical Installations Of Sub-Station And Dg Sets Including Operation, Repairs And Maintenance, Attending Faults / Breakdown Rectifications, Ensuring Serviceability / Satisfactory Working Conditions Of The System, Attending Complaints, Preventive Maintenance And Maintenance Of Records / Documentation Etc. As Per Detailed Specifications, Terms And Conditions Covered Under This Contract On All Days Including Saturdays, Sundays And Holidays As Per Tender Specifications, Terms And Conditions By Providing Following Manpower As Per Requirement For Round The Clock Operation In Three Shifts Per Day. ( A ) Skilled-03 Nos. ( I.E. 01 No. In Each Shift For Round The Clock Operation And Reliever Shall Be Provided On Weekly Off / Holiday ) ( C ) Unskilled - 03 Nos. ( I.E. 01 No. In Each Shift For Round The Clock Operation And Reliever Shall Be Provided On Weekly Off / Holiday ) Note- Contractor Has To Provide Reliever On Weekly Offs / Holidays Of Above Required Staffs. 3 Sub-Head B ( Services ) Annual Comprehensive Maintenance Of Inverter / Non- Inverter Split Type Room Air Conditioner Units Of Following Capacity, Different Makes Including Stabilizer ( If Any ) Installed At Different Locations Inclusive Of All Spares, Materials Involving Repair And Maintenance As Per Manufacture Schedule, Servicing Including Routine Preventive Maintenance, Breakdown Maintenance Including Repair / Replacement Of Compressor, Electronic Circuit Board, Mechanical, Equipment, Safety Controls And Instrumentations Gas Charging, Fan, Fan Motors, Thermal Insulation, Etc. Ensuring Serviceability / Satisfactory Working Condition Of The System, Maintenance Of Recordes / Documentation Etc. As Per Tender Conditions Covered Under This Contract On All Days Including Sunday And Holiday Etc. As Required. A 2.0 Tr, 1Phase, 230 V, 50 Hz Split Ac Unit 4 Annual Comprehensive Periodical Maintenance Of Vrv Type Outdoor Air Conditioner Units Of Capacity, And Cassette Type Indoor Units Of Daikin Makes, Model No. Rxyq20ary6 ( 5Nos. Vrv Unit Each 20Hp 3Phase, 380-415V, 50 Hz, With 20 Nos. Indoor Cassette Type Units ) Installed At Terminal Building Inclusive Of All Spares, Materials Involving Repair And Maintenance As Per Manufacturer Schedule, Servicing Including Routine Preventive Maintenance, Breakdown Maintenance Including Repair / Replacement Of Compressor, Electronic Circuit Board, Mechanical, Equipment, Safety Controls And Instrumentations Gas Charging, Fan, Fan Motors, Thermal Insulation, Etc. Ensuring Serviceability / Satisfactory Working Condition Of The System, Maintenance Of Recordes / Documentation Etc. As Per Tender Conditions Covered Under This Contract On All Days Including Sunday And Holiday Etc. As Required. 5 Supply And Laying Of Refrigerant Copper Piping Including Top Up Of Gas Charging Suitable For 1.5Tr / 2Tr / 2.5Tr Capacity Of Different Type Ac Units, Both Suction And Discharge Along With Suitable Thermal Insulation And Electrical Cable Of Size 4 Core X 4 Sq. Mm Copper Conductor For Connection From Indoor To Outdoor Unit And Suitable Necessary Accessories For Connection Complete For Shifting / Reinstallation Of Acs As Per Site Requirement. ( One Lengths Of Suction, Discharge Piping And Length Of Copper Wire Shall Be Measured One Meter For This Item ) 6 Annual Comprensive Maintenance Of Water Cooler ( Make- Voltas Model No. Voltas Wc Fs 40 / 80Np ) Installed At Terminal Building, Inclusive Of All Spares, Materials Involving Repair And Maintenance As Per Manufacturer Schedule, Servicing Including Routine Preventive Maintenance, Breakdown Maintenance Including Repair / Replacement Of Compressor, Electronic Circuit Board, Mechanical, Equipment, Safety Controls And Instrumentations, Gas Charging Etc. Ensuring Serviceability / Satisfactory Working Condition Of The System, Maintenance Of Recordes / Documentation Etc. As Per Tender Conditions Covered Under This Contract, Providing All Necessary Consumables Complete As Required ( Maintenance To Be Done Through Oem / Authorized Dealer / Local Specialised Agency. 7 Annual Comprensive Maintenance For Ro System Upto 50 Litre Capacity Including Replacement Of All Defective Components And Carrying Out Bi-Monthly Service Activity At Installed Position Etc. As Required. The Supply Of Consumable Spares, Membrane And Filters As Mentioned In 7B Is Not Included In The Scope Of This Item However Installtion And Satisfactory Working Of Equipments Covers In This Item. 8 Replacement Of Following Filter For Above Ro System Etc. Complete As Required. I Shield Membrane 9 Replacement Of Following Filter For Above Ro System Etc. Complete As Required. Ii Carbon / Sediment Filter 10 Rewinding, Servicing, Repairing Of Following Fans Including Replacement Of Worn-Out / Defective Parts Like Copper Wire, Insulation, Bearings, Capacitors Etc., I / C Transportation From Site To Workshop And Back To Site. ( By Back Dismantled Material ) . A Ceiling Fan 11 Rewinding, Servicing, Repairing Of Following Fans Including Replacement Of Worn-Out / Defective Parts Like Copper Wire, Insulation, Bearings, Capacitors Etc I / C Transportation From Site To Workshop And Back To Site. ( By Back Dismantled Material ) B Wall Fan / Pedestal Fan 12 Rewinding, Servicing, Repairing Of Following Fans Including Replacement Of Worn-Out / Defective Parts Like Copper Wire, Insulation, Bearings, Capacitors Etc I / C Transportation From Site To Workshop And Back To Site. ( By Back Dismantled Material ) . C Exhaust Fan 13 Lifting And Lowering Of Submersible Pump Of Various Capacities ( Up To 15 Hp ) Due To Defect In Existing Pump On Urgent Basis Within A Short Notices Including Connection Of Cables Jointing Of Cables Etc. With Successful Testing And Commissioning Complete As Required. 14 Repair And Rewinding Of Upto 15Hp Capacity Submersible Pump Motor Sets. Job Include Transportation Of Motor Dismantling And Rewinding With The Same Gage Insulated Copper Wire Including Replacement Of All The Internal Worn Out / Defective Parts I.E. Bushes, Impellers, Sleeves, Upper And Lower Bushes Sets, Thrust Bearing, Oil Seals, Rotor Grinding And Balancing, Assembling, Testing, Transportation Etc. Complete As Required. ( By Back Dismantled Material ) . 15 Refilling Of Fire Extinguisher Of Following Type And Capacity As And When Required. A Co2 Type- 4.5Kg Capacity 16 Refilling Of Fire Extinguisher Of Following Type And Capacity As And When Required. B Co2 Type- 6.5Kg Capacity 17 Refilling Of Fire Extinguisher Of Following Type And Capacity As And When Required. C Abc Type 4Kg Capacity 18 Refilling Of Fire Extinguisher Of Following Type And Capacity As And When Required. D Abc Type 6Kg Capacity 19 Annual Maintenance Contract Of Kirloskar Make 62.5Kva Dg Set Including Amf Panel And Preventiove Maintenance By Authorised Service Engineer ( Minimum One Visit In Three Months ) And Attending Any Nos. Of Breakdown Calls As Per Terms And Conditions Of Tender Including B Check From Authorised Dealers Of Oem. Make Of Dg Set- Koel, Serial No. Sl. No Ac Generator- Lbs3k 19F9138-H Make- Kirloskar Oil Engines Limited Sl. No Engine-T4.8904 / 1920003 Make- Kirloskar Oil Engines Limited A Quarterly Visit. 20 Annual Maintenance Contract Of Kirloskar Make 62.5Kva Dg Set Including Amf Panel And Preventiove Maintenance By Authorised Service Engineer ( Minimum One Visit In Three Months ) And Attending Any Nos. Of Breakdown Calls As Per Terms And Conditions Of Tender Including B Check From Authorised Dealers Of Oem. Make Of Dg Set- Koel, Serial No. Sl. No Ac Generator- Lbs3k 19F9138-H Make- Kirloskar Oil Engines Limited Sl. No Engine-T4.8904 / 1920003 Make- Kirloskar Oil Engines Limited B B Check ( All Parts To Be Replaced As Per Special Condition ) 21 Annual Maintenance Contract Of Greaves Make 125Kva Dg Set Including Amf Panel And Preventiove Maintenance By Authorised Service Engineer ( Minimum One Visit In Three Month ) And Attending Any Nos. Of Breakdown Calls As Per Terms And Conditions Of Tender Including B Check From Authorised Dealers Of Oem. Make Of Greaves Set- Engine Serial No. 1308041908102 Engine Model- 4G11tag26 ( Dom 17 / 02 / 2019 ) Ac Generator- Sl No. Sgag0365 A Quarterly Visit. 22 Annual Maintenance Contract Of Greaves Make 125Kva Dg Set Including Amf Panel And Preventiove Maintenance By Authorised Service Engineer ( Minimum One Visit In Three Month ) And Attending Any Nos. Of Breakdown Calls As Per Terms And Conditions Of Tender Including B Check From Authorised Dealers Of Oem. Make Of Greaves Set-Engine Serial No. 1308041908102 Engine Model- 4G11tag26 ( Dom 17 / 02 / 2019 ) Ac Generator- Sl No. Sgag0365 B B Check ( All Parts To Be Replaced As Per Special Condition ) . 23 Annual Maintenance Of Micro Processor Controlled Ccrs Of Nasu Make Including Repairing Of Defective Ccrs By Identifying The Fault, Replacement Of Defective Pcbs And Other Components And Service The Same, Including Calibration / Checking Of The Protection Circuits, Insulation Monitor Circuits And Brightness Controls Of Mpccrs And Complete Checking, Servicing On Quarterly Basis Etc. As Required As Per The Directions Of Engineer-In-Charge And Submission Of Test Reports Etc As Per Manufacturer Recommendations Of Nasu Make ( All The Components Required For Servicing Of Mpccrs Will Be Supplied By Aai ) . A 4 Kw, Microprocessor Controlled Nasu Make Ccr ( I ) Sr. No. Ns / Mpccr / 09 / 2019 / 09 24 Annual Maintenance Of Micro Processor Controlled Ccrs Of Nasu Make Including Repairing Of Defective Ccrs By Identifying The Fault, Replacement Of Defective Pcbs And Other Components And Service The Same, Including Calibration / Checking Of The Protection Circuits, Insulation Monitor Circuits And Brightness Controls Of Mpccrs And Complete Checking, Servicing On Quarterly Basis Etc. As Required As Per The Directions Of Engineer-In-Charge And Submission Of Test Reports Etc As Per Manufacturer Recommendations Of Nasu Make ( All The Components Required For Servicing Of Mpccrs Will Be Supplied By Aai ) . A 4 Kw, Microprocessor Controlled Nasu Make Ccr ( Ii ) Sr. No. Ns / Mpccr / 09 / 2019 / 09 25 Sitc Of 5Kva Inverter With 4Hours Backup Including Batteries, All Connection, Interconnecting Cables And Inverter For Backup.Time Of 4Hours, Trolly For The Inverter And Must Be Suitable To Opereate At Full Load, Auto Cutoff System After Full Charge, Auto Switch On After Power Failure Etc As Required. 26 Dismantling Of High Wall Split Type Air Conditioning Unit , Re-Installation, Testing And Commissioning Of Capacity Up To 2 Tr. Air-Conditioner Units , Fixing Of Existing Refrigerant Pipe, Insulation And Existing Flexible Copper Conductor Cable Between Evaporator And Condenser Units, Topping Up Refrigerant Gas Etc. Complete As Required As Per Direction Of Eic. 27 Sub-Head C ( Supply Of Items ) Supply Of Following Sizes Self Supporting Foldable Type Aluminium Ladder, Made Of C Section, Heavy Duty, Light Weight, Long Lasting, Easy To Carry And Store, Fold And Open, Provided With Edge Protectors, Rust Proof And Skid Proof Bottom And Provided With Anti Skid Pvc / Rubber Shoes And With Good Anodized Finish, Powder Coated Etc Complete As Required. A 8 Feet ( Make Alco Model- Ladder Al -110 Or Equivalent ) 28 Supply Of Following Sizes Self Supporting Foldable Type Aluminium Ladder, Made Of C Section, Heavy Duty, Light Weight, Long Lasting, Easy To Carry And Store, Fold And Open, Provided With Edge Protectors, Rust Proof And Skid Proof Bottom And Provided With Anti Skid Pvc / Rubber Shoes And With Good Anodized Finish, Powder Coated Etc Complete As Required. B 18 Feet ( Extension Ladder ) Self Support Extension Ladder ( Make- Alco Model Al – 105 ) 29 Supply Of Following Sizes Pvc Insulated, Pvc Round Sheathed Multicore Industrial Cables For Voltage Grade Upto 1100 V As Per Is 694-1990. A ) 3 Corex2.5Sqmm ( Each Coil 100Mtrs ) 30 Supply Of Following Sizes Pvc Insulated, Pvc Round Sheathed Multicore Industrial Cables For Voltage Grade Upto 1100 V. As Per Is 694-1990. A ) 3 Corex4sq.Mm ( Each Coil 100Mtrs ) 31 Supply Of Following Sizes Of 1.1 Kv Grade, Single Core Fr-Lsh Pvc Insulated Industrial Grade Copper Conductor ( Unsheathed ) Confirms To Is 694.With Up To Date Amendments Etc As And When Required ( Each Coil 180Mtrs ) A I ) 1.5 Sq.Mm. ( Red 1 Nos. Black 1Nos. Green 1Nos. ) 32 Supply Of Following Sizes Of 1.1 Kv Grade, Single Core Fr-Lsh Pvc Insulated Industrial Grade Copper Conductor ( Unsheathed ) Confirms To Is 694.With Up To Date Amendments Etc As And When Required ( Each Coil 180Mtrs ) B Ii ) 2.5 Sq.Mm. ( Red 1 Nos. Black 1 Nos. Green 1Nos. ) 33 Supply Of Following Sizes Of 1.1 Kv Grade, Single Core Fr-Lsh Pvc Insulated Industrial Grade Copper Conductor ( Unsheathed ) Confirms To Is 694.With Up To Date Amendments Etc As And When Required ( Each Coil 180Mtrs ) C Iii ) 4 Sq.Mm. ( Red 1 Nos. Black 1 Nos. ) 34 Supply Of 1.1Kv, 10Cx1.5 Sqmm, Copper Conductor Pvc Insulated, Pvc Sheathed Armoured Copper Control Cable Conforming To Is 7098 Part 1 And Upto Date Ammendment 35 Supply Of 4C X 16 Sq.Mm, Xlpe Insulated And Pvc Sheathed Armoured Aluminium Conductor Power Cable Of 1.1 Kv Grade Conforming To Is 7098 ( Part-1 ) With Upto Date Ammendments Etc. Complete As Required 36 Supply Of 4C X 25Sq.Mm, Xlpe Insulated And Pvc Sheathed Armoured Aluminium Conductor Power Cable Of 1.1 Kv Grade Conforming To Is 7098 ( Part-1 ) With Upto Date Ammendments Etc. Complete As Required 37 Supply Of 200W 20 / 6.6 Amp Isolating Transformer As Required. 38 Supply Of Landing T Doms Etc As Required. 39 Supply Of 9W Led Thread Type Landing T Bulb Etc As Required. 40 Supply Of Spares Required At Site During Repairing / Servicing For 4Kw Microprocessor Ccr Etc. Complete As Required. I Microprocessor Main Control Card 41 Supply Of Spares Required At Site During Repairing / Servicing For 4Kw Microprocessor Ccr Etc. Complete As Required. Ii Display Card 42 Supply Of Spares Required At Site During Repairing / Servicing For 4Kw Microprocessor Ccr Etc. Complete As Required. Iii Power Supply And Driver Card 43 Works Based On Dsr ( Eandm ) -2022 Items. Rate For Each Rupee Value Of Work Executed From The Cpwd Dsr ( Eandm ) 2022 Electrical Rates. ( For Example If The Quoted Rate For This Item Is Rs 0.9 Then The Executed Dsr-2022 ( Electrical ) Schedule Works Of Value Rs 200000.00 At Dsr-2022 ( Electrical ) Rates, The Quoted Amount Willbe Rs 180000.00 And If Quoted Rate For This Item Is Rs 1.25 The Quoted Amount For The Same Will Be Rs 250000.00 Total Quantity : 699

Key Value

Document Fees
Refer document
EMD
INR 95507.0 /-
Tender Value
INR 47.75 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail