Tender For Conservation, Restoration And Development Of Thongnambonbi (Hump Bridge)., Imphal West-Manipur

Health And Family Welfare Department has published Tender For Conservation, Restoration And Development Of Thongnambonbi (Hump Bridge).. Submission Date for this Tender is 29-05-2023. Bridge Work Tenders in Imphal West Manipur. Bidders can get complete Tender details and download the document.




Tender Notice

37758751
Corrigendum : Tender For Conservation, Restoration And Development Of Thongnambonbi (Hump Bridge).
Open Tender
Indian
Manipur
Imphal West
29-05-2023

Tender Details

Conservation, Restoration And Development Of Thongnambonbi (Hump Bridge).

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-May-2023 TIME EXTENSION FOR CONSERVATION, RESTORATION AND DEVELOPMENT OF THONGNAMBONBI (HUMP BRIDGE). Date 29-05-2023

Key Value

Document Fees
INR 25000 /-
EMD
INR 1300000.0 /-
Tender Value
INR 6.50 Crore /-

BOQ Items

Name of Work: CONSERVATION, RESTORATION AND DEVELOPMENT OF THONGNAMBONBI (HUMP BRIDGE)
Sl. No. Item Description
1CONSERVATION, RESTORATION AND DEVELOPMENT OF THONGNAMBONBI (HUMP BRIDGE)
2Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing itthereafter.The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge.
3Provision of Diverting Water by making coffer dam and making area dry for working manually as well as mechanically through out the duration and again rediverting water after complication of work
4Centering and shuttering including strutting, propping etc. and removal of form for:
5Arches, domes, vaults upto 6 m span
6Sterilizing treatment using Biocide: Masonry covered with algae, lichen, mosses, small plants, etc should be removed with knife blades, spatula and stiff bristle or soft wire brushes. Spray diluted solution of quaternary ammonium based biocide on surface of the masonry with out allowing to spray drift. Leave the treated area for at least one week than brush off as much dead growth as possible. Next again spray a solution of a proprietary biocide and incorporating tribute tin oxide in same manner and clean the surface.
7Manually removal of vegetation (major trees, climbing plants, creepers) from walls, columns, arches, floor etc in a skilled and careful manner, using appropriate tools and means and without causing any damage to the adjoining parts, including carrying and stacking the dismantled materials including lift/lower upto 11mtrs and lead upto 50 mtrs as directed by the engineer or architect in charge. The exposed surfaces will be coated with a paste made from ammonium sulphamate crystals or with "Tree killer" available in market. In this condition the root system may be left to absorb and die. Large sections of dead wood must not be left within the core. As they decay they will remove support and create voids and weaknesses in the wall. Pull off a well-established mat of vegetation must be resisted. Tamping, grouting, pointing and resetting of brick / stones especially on wall top, must all be anticipated as remedial work.
8Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete - MS Platform for walking as well as supporting beneath the bridge
9Demolishing brick work manually/ by mechanical means including stacking ot serviceable material and disposal ot unserviceable materialwithin 50 metros lead as per direction of Engineer-incharge
10In cement mortar
11Dismantling steel work in built up sections in angles, tees, flats kg3.21 and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lèad.
12Raking out joints in lime or cement mortar and preparing thesqm surface for re-pointing or replastering including disposal Of rubbish to the dumping ground within 50 metres lead.
13Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
14Flush / Ruled/Struck or Weatheredd lime pointing 1:1:1 ( 1 Slaked lime:1 surkhi:1 fine sand) In Brickwork
1530-40mm lime plaster in two coats with 20mm base coat in lime mortar 1:1:1 (1 lime : 1 Surkhi :1 Coarse Sand) and top coat in lime mortar 1:1:1 (1 lime : 1 Surkhi :1 Fine Sand)
16Lime punning with lime putty mixed with Gur,Bilgri,Urd and other ingredients followed by grinding to fine paste for smooth finish
17Stone work in plain ashlar masonry in superstructure in lime mortar 1:1:1 (1 lime:1 surkhi:1 coarse sand) including pointing with lime mortar and an admixture of pigmen matching the stoneshade. White sand stone
18Lime concrete at plinth protection , coping , slab etc Providing and laying lime concrete with graded brick aggregate 50 mm nominal size and 50% mortar comprising of 1 lime putty : 2 coarse sand rammed excluding cost of centring and shuttering
19Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
20Providing protective coating of water repellent siloxane (transparent in color) through brush or spray untill complete impregnation over completely cleaned and dried stone or plastered surface to reduce the absorption of water.
21Providing and supplying hot lime grouting using fine sand 1:2 use of unslack hydraulic lime for same depending upon site condition use of surkhi for cavity and opening in masonary. In existing structure
22Providing /supplying & fixing of Helifix make Hi-Fin reinforcement Bars-Helibar having 6mm Dia MOC. Austenitic Stainless Ateel ASTM 304 having cross section area 8.3mm2 with UTS 1150n/mm2 at various places where there is cracks in Stone Msonary /Arches .Item includes HELIFIX & HELIBOND Grout a special cementitious grout with low expansion ,non-gasing & injectables with exceptional thixotropic properties is to be used to bond the stainless steel Hi-Fin reinforcement bars & pins with the help of pressure gun to be injected in the slot of stone Masonary .ensuring that it remains tight in the joint after curing .Item also include Crackbond TE -250ml a injectable special epoxy resin with the help of Crackbond applicator ensuring that it covers entire cracked area wherever required
23Providing supplying and fixing of Helifix make Hi-fin reinforcement bars-Cemtie 8mm dia MOC. Austenitic stainless steel , ASTM 304, having cross section area of 9.5 mm 2 with UTS 1375n /mm2 at various places where there is crack in brick/stone masonry as directed by structural engineer/Helifix. Inclusive of supplying and fixing of Helifix make Helibond grout a special cementious grout with low expansion,non-gassing and injectable with exceptional thixotropic properties is to be used to bond the stainless steel Hi-fin reinforcement bars and pins with the help of pressure gun to be injected in the slot of stone masonry, ensuring that it remains tight in the joint after curing. inclusive of supplying and filling of Crackbond TE 250 mlan injectable special epoxy resin with the help of crackbond applicator wherever necessary.
24Creating a HeliBeam using Helibars 6mm: Providing and fixing of Helifix make Hi-fin reinforcement Helibars of 6mm dia, double bars in one slot, MOC austenitic stainless steel as per ASTM 304, having cross-section area of 8 sq.mm, pitch 29/30, with UTS 980 N, shear strength 5.5 kN, along with Helibond grout, a special cementitious grout with low expansion, non-gassing and injectable with exceptional thixotropic properties. Including chasing of bed joints for HeliBars in brick/stone/block masonry, cleaning and dampening with water to achieve good bonding of HeliBar with HeliBond grout in the slot of masonry ensuring that it remains tight at the joint after curing, including filling of general purpose styrene free resin with the help of manual pressure applicator and nozzle, to be used for anchoring the ends of helical bars wherever needed at locations as per instructions provided by Structure Engineer / Helifix, excluding Staging & Scaffolding, at places wherever necessary.Item also include Crackbond TE -250ml a injectable special epoxy resin with the help of Crackbond applicator ensuring that it covers entire cracked area wherever required.
25Creating a HeliBeam using Helibars 8mm: Providing and fixing of Helifix make Hi-fin reinforcement Helibars of 8mm dia, double bars in one slot, MOC austenitic stainless steel as per ASTM 304, having cross-section area of 9.5 sq.mm, pitch 29/30, with UTS 980 N, shear strength 5.5 kN, along with Helibond grout, a special cementitious grout with low expansion, non-gassing and injectable with exceptional thixotropic properties. Including chasing of bed joints for HeliBars in brick/stone/block masonry, cleaning and dampening with water to achieve good bonding of HeliBar with HeliBond grout in the slot of masonry ensuring that it remains tight at the joint after curing, including filling of general purpose styrene free resin with the help of manual pressure applicator and nozzle, to be used for anchoring the ends of helical bars wherever needed at locations as per instructions provided by Structure Engineer / Helifix, excluding Staging & Scaffolding, at places wherever necessary.Item also include Crackbond TE -250ml a injectable special epoxy resin with the help of Crackbond applicator ensuring that it covers entire cracked area wherever required.
26Stitching the cracks in Stone/Brick masonry using Stainless Steel Patta and bolts by cutting, welding, hoisting, fixing using nut-bolts as including designe etc. required.
27Excavation work by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m.
28Ordinary rock
29Extra for every additional lift of 1.5 m or part thereof in
30Ordinary rock
31Clearance of land slips in all type of soils hill road i/c disposal of excavated soil, rubbish etc. upto a lead of 50 metres
32Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete.
33Providing, hoisting and laying of stone base plate ofsize(450X 600X 150 MM ) under I sections/woodenbeams on the end wall for placing the structural steel/woodenbeam, as per the specification
34Extra for random rubble masonary with hard stone in superstructute above floor V level for every four floors or part thereof.
35Providing and applying CEMENT PLASTER IN COARSE SAND 15 mm cement plaster
361:4 (1 cement: 4 coarse sand).
37Brick work in plain arches in superstructure above plinth level and upto floor five level including centering and shuttering complete for span upto 6 metres with 1st class common burnt F.P.S. bricks(non modular) in cement mortar 1:3 (1 cement: 3 coarse sand).
38Brick work in gauged arches in superstructure above plinth level and upto floor five level in cement mortar 1:3 (1 cement : 3 coarse sand) including centering and shuttering complete, for span upto 6 meters with 1st class F.P.S. bricks (non modular).
39Providing and making SS Signages with proper Ethyl paint for the monuments including Sketch , image in colour with Size 4" X 3"
40Brick on edge flooring with bricks of 1st class on bed of 12 mm cement motar including filling the joints with the same motar with common burnt clay non modular bricks
411:4 (1 cement: 4 coarse sand).
42Providing , Careful hosting& PlacingCast Iron work in single section fixed with or without connecting plate including cutting hoisting, fixing in position and applying a anti rust paint over priming coat of approved steel primer & Paint , as directed by Engineer incharge/ Architect, Including all formwork, proping etc. required.
43Providing and fixing of New carvedstone in all thickness wherever required upto all level/heightin plain/decorative work carved by manual/mechanical methode including base(dasa) ,shaft ,capital of columns , springer ,key stone of arches, Decorative stoneband at plinth level. etc as per old design including coldrollstainless steel clamp,copper pins of requireddiameter for securing adjacent stones in stone wall lining ,Providing and fixing stone dowelscut to double wedge shape as per old design including making the necessary chases.Item includes cost of mortar /adhesive /safety measure /use of specified equipment for workers requiredtocomplete the work.(Overall length , width and thickness of stone (cut stone / replaced new stone quantity)will be measured for the purpose of payment)
44Provding and fixing cast Iron bench stone Benches as per Site Condition.
45Providing Mild Steel litter bins with Powder Coating finish of size: 23.62” Dia x 31.49” Height and holding capacity of 50 Litres.
46Providing, fabricating and erecting on site street name board. Vertical pole shall be of hot dip galvanized M.S. square pipe of size 100mm x 100mm x 3.5mm thick. Signage box shall be of size 1500mm x 600mm made of hot dip galvanized M.S. square pipe of size 50mm x 50mm x 2mm thick covered with 4mm thk, 0.5mm alskin thk aluminum compostie pabel on both sides as shown in drawing. The signage box assembly shall be welded to the vertical pole. The retro reflective sign board of size 1500mm x 600mm shall be made of Type XI standards as per IRC 67-2012 which shall be pasted on to 4mm thick ACP sheet on both sides that shall be riveted to the square box as shown in drawing. Letters or borders shall be printed on the retro reflective sheeting using printed approved by the sheeting manufacturer and laminated using suitable UV protective laminate. The vertical pole shall be fixed to the ground by means of properly fitted foundation with base plate 200mm x 200mm x 6mm thick and "J" GI bolts as mentioned in the approved drawing. Complete as per specification and as directed by the engineer.
47Providing, fabricating, erecting on site Facility Information Sign Board onto electric pole. Signage shall be of size 600mm x 800mm rectangle as per approved structural drawing. The board shall be made of 4mm ACP with back support frame of Aluminum C section of size 33 x 33 x 33 x 2mm thick fixed using an Aluminum clamp of 3mm thick with suitable GI nut bolt on to the electrical pole. The board shall be pasted with MICRO PRISMATIC GRADE retro reflective base sheets conforming to Type XI standards of I.R.C. 67 2012 CODE. Letters or borders shall be printed approved by the sheeting manufacturer and laminated using suitable UV protective laminate. Complete as per the specification and directed by the engineer.
48Providing, Fabricating, Erecting on site Cautionary Boards onto electrical pole. Signage shall be of size 600mm triangle as per the approved structural drawing. The board shall be made of 3mm ACP with back support frame of Aluminum C section of size 33 x 33 x 33 x 2mm thick fixed using an Aluminum clamp of 3mm thick with suitable GI nut bolt onto the electrical pole. The board shall be pasted with MICRO PRISMATIC GRADE retro reflective base sheets conforming to type XI standards of I.R.C. 67 2012 CODE. Letters or borders shall be printed on the retro reflective sheeting using printer approved by the sheeting manufacturer and laminated using suitable UV protective laminate.Complete as per the specification and directed by the engineer.
49Providing, Fabricating, Erecting on site Mandatory Boards onto electrical pole. Signage shall be of size 600mm dia as per the approved structural drawing. The board shall be made of 3mm ACP with back support frame of Aluminum C section of size 33 x 33 x 33 x 2mm thick with suitable GI nut bolt on to the electrical pole. The board shall be pasted with MICRO PRISMATIC GRADE retro reflective base sheets conforming to Type XI standards of I.R.C. 67 2012 CODE. Letters or borders shall be printed on the retro reflective sheeting using printer approved by the sheeting manufacturer and laminated using UV protective laminate.Complete as per the specification and directed by the engineer.
50Providing & rooting the flora/Plant/Flowersat site including Planting,watering in level, cleaning etc. complete as per consultant Design .
51American Grass turf
52Plumeria Rubra
53Euphorbia Milli
54Tibouchina Urvilleana
55Kalanchoe Blossfeldiana
56Plumbago Indica
57Polinthes Tuberosa
58Ixora Coccinea
59Verbena hybrid
60Providing and fixing cast Iron Bollards as per given design by the Architect which included cutting,bending,installation and duco Painting etc. complete.
61Providing and fixing Cast Iron chain (Length 1.2mtr)for connectingBollards as per given desgn by the Architect which includes cutting,bending,installation and duco Painting etc. complete.
62Construction of Panel cum server room including provision of DMX server and all electrical panels, controller etc
63Supply and installation of porta cabin , The paneling of side walls and end walls shall be of min. 1 mm thick resin bonded plastic decorative laminate sheets fixed on min. 8 mm thick commercial quality plywood. The roof panels shall be min. 4 mm thick commercial quality plywood of same specification covered with min. 1 mm thick resin bonded plastic decorative laminate of same quality and design as in the case of inner panels. All wall and roof panels shall be supported by suitable M.S. Frame work. Including all necessary electric connection fan, lights complete for security of size 20 x 10 ft
64Provision of Triple Self-Cleaning Electronic ECO-Toilet 1. Fabricated public toilet made of stainless steel (SS 304) inner layer with thickness 1.2mm /1.3mm and outer layer of Aluminum Composite (Alco-panel) of 6mm. 2. Foam is place between inner and outer layer for pleasant temperature inside. 3. Inside Dimension (LxWxH): 1 x 1.2x 2meters 4. Toilet Size (LxWxH): 2 x 2.5x 2meters 5. Area required for installation of toilet: 90 Sq. ft. 6. Area required for installation of Bio- digester (LxWxH): 6.5ft x4.5ft x6ft underground. 7. Stainless Steel platform & closet - Indian. 8. Overhead water tank with capacity: 500+500+500=1500 Ltr. 9. Bio-Digester tank with capacity: 3000 Ltr. 10.Toilet status display – Vacant/Busy/Water Low Level Indication. 11.Coin based automated entry. 12.Manual exit. 13.Automated light & exhaust fan. 14.GSM connectivity 15.Self-cleaning and washing mechanism (Flushes, Floor & Wall wash). 16.Online surveillance system for entry and voice assistance. 17.Low Water Level Indication using Water level sensor. 18.Baby Child Changing Station will be provided inside female toilet. 19.Accessories like Wash basin, Health Faucet & Cloth Hanger etc. 20.Power backup facility UPS and 30 AH battery.
65Construction of footpath/separator by providing a 150 mm compacted granular sub base as per clause 401 and 25 mm thick cement grade M15,over laid with pre-cast concrete tiles in cement mortar 1:3 including provision of all drainage arrangements but excluding Kerb channel..
66Providingand laying in positioncement concreteof specified gradeexcludingthe cost of centering andshuttering-all work upto plinth level.
671:4:8( 1cement:4 coarse sand:8 gradedstone aggregate 40mm nominal size)
68Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (I cement: 4 coarse sand):
6925 mm thick.
70ELECTRICAL WORK
71Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceilingerected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed (b) 25 mm
72(c) 32 mm
73Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC bushes, Check-nuts etc. complete of following sizes.(2) 25 mm
74(3) 32 mm
75Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness
76150 mm width X 50 mm depth X 1.6 mm thickness
77Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipeto be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size (e) in existing pipe (a) 2 wire 1.5 sq. mm
78(d) 3 wire 2.5 sq. mm
79Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size (e) in existing pipe (a) 2 wire 4 sq. mm
80Providing & erecting 240 V MCB double pole switch for motor & inductive load(C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity (A) 40 AMP
81Providing & erecting 415 V MCB Four Polefor Motor & InductiveLoad (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity (a)25 Amp.
82(b)40 Amp.
83(c)63 Amp.
84Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used)(H) Single phase 12 way SS Double door
85(L) Three phase 6 way SS Double door for single phase outgoing horizontal box
86(N) Three phase 8 way SS Double door for horizontal single phase outgoing
87Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. (i) 25 Amps.FP
88(ii) 40Amps. FP
89(iii) 63 Amps. FP
90Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(F) 3 core 4 Sq. mm
91(K) 4 core 4 Sq. mm
92Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copperconductor for1.1 KV. to be laidon wall with necessary clamps or in existingtrench/ pipe at road crossing or floorof followingsize of cables.(A-1) 4 core 4 Sq. mm
93(C) 4 core 10 Sq. mm
94(D)4 core 16 Sq. mm
95Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables.(b) 2 to 4 core 4 Sq. mm
96(c) 2 to 4 core 6 Sq. mm
97(d) 2 to 4 core 10 Sq. mm
98Solderless crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (A) 1.5/2.5 to 6 Sq.mm
99(B) 10 Sq.mm
100(C) 16 Sq.mm.
101SETC of SurfaceMounted LED Spot, 1800-2000 Lumen, as per detail technical specification.
102Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
103Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
104Supply and Installation of approved make unarmoured 4 Sqmm 4 core single conductor fr pvc insulated 1100V cable as directed by eic.
105Supply and installation of IN-OUT (Male-Female) Connectors with IP65 rating for the connection of each lights as directed by eic.
106Supply and Installation of approved make outdoor Weatherproof Termite resistant Easy Cable entry, bottom & top Tamper proof Pilferage proof Restricts unauthorized tapping Maintenance-free Rustproof / Shockproof High heat distortion temperature IP65 Enclosure of size 300X200X130 .
107Same as above but Enclosure of size 140X140X95
108Supply and Fixing of Flange Type Brass cable gland for armoured cable
109Supply and Fixing of PVC Cable gland for PVC insulated cable
110Supply, installation, testing and commissioning of Following hot dip galvanised vertical square(100 X 100 MM Class C Pole) shape pole with inbilt IP67, 55W LED Light Fixture/s complate withreflector system encased in clear UV protected polycarbonet diffuser for distribuiton of light. Thefixture shall be provided with sutable driver and other required acssories. The pole shall be epoxyzinc rich penetrating primer and finishing with polyester powder coated of approved shed. IP54 Integral control gear box complate with rust free zinc cast lock & key, sealed with silicon rubbergasket, GI chain link etc. provided to interlink the pole & control box cover. Control gear tray isprewired with MCB connector and loop in & loop out terminal block sutable for the cable selected.The pole shall be mounted on surface mounting base plate with Hot dip GI.Foundation bolt &nuts.Base plate size & thickness shall be sutable for the minimum of wind speed 55km/hr & Pole load. 4.5mtr Height pole square shape Column with one Light fixture on One Side.
111Supply, installation, testing and commissioning of Following hot dip galvanised vertical square(100 X 100 MM Class C Pole) shape pole with inbilt IP67, 55W LED Light Fixture/s complate withreflector system encased in clear UV protected polycarbonet diffuser for distribuiton of light. Thefixture shall be provided with sutable driver and other required acssories. The pole shall be epoxyzinc rich penetrating primer and finishing with polyester powder coated of approved shed. IP 54Integral control gear box complate with rust free zinc cast lock & key, sealed with silicon rubbergasket, GI chain link etc. provided to interlink the pole & control box cover. Control gear tray isprewired with MCB connector and loop in & loop out terminal block sutable for the cable selected.The pole shall be mounted on surface mounting base plate with Hot dip GI.Foundation bolt & nuts.Base plate size & thickness shall be sutable for the minimum of wind speed 55km/hr & Pole load. 4.5mtr Height pole square shape Column with two Light fixture on opposite Side.
112Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withou MCB/RCCB/Isolator) 4 way (4 + 12), Double door
113Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 40 mm
114SETC of LED Type Decorative Post top lantern IP66, 4000-5000 Lumen, having Antique/ Heritage Look. With GI suitable for post topPole 3.0 Mtr. Ht. with Base Plate made out of GI pole, primer and painted with polyurethanebased paint. The Pole shall be suitable to mount 1 no of above Post top Lantern, maximum 3 no CCTV camera & maximum 2 no of Outdoor Speaker. Arrengment as shown by consultant. (Cost of CCTV & PA Bracket shall be exluded). As per Detail Technical Specification. (Including Pole & Luminary)
115SETC of LED Decorative lantern IP66, 4000-5000 Lumens, having Antique/ Heritage Look with Antique Design wall Mounted Bracket,
116SETC of Spike light Mounted LED Spot, 1800-2000 Lumen, as per detail technical specification.
117Supply, Erecting, Testing, Commissioning & Programmingof DMX Compatible 2 Feetarchitectural Linear wall washer light Luminaires. As per details specification
118Supply, Erecting, Testing, Commissioning & Programmingof DMX Compatible 4 Feetarchitectural Linear wall washer light Luminaires. As per details specification
119Supply, Erecting, Testing, Commissioning & Programmingof DMX Compatible 20-25 W architectural wall washer Flood Light Luminaires. As per details specification
120Supply, Erecting, Testing, Commissioning & Programmingof DMX Compatible 45-55 W architectural wall washer Flood Light Luminaires. As per details specification
121SETC & Programming of DMX Engine Including S2 power supply as per detail technical specification. These Engines shall be the perfect platform for building dynamic, effective and reliable lighting applications. These engines shall be the functional backbone of lighting installations controlling fixtures, interacting with user terminals and executing shows. These engines shall be built for steadiness, long-term use and flexibility. They shall feature-rich and benefit from many years pioneering work in the fieldof lighting control. A DMX engine that can be used either in standalone mode to replay and loop previously uploaded lighting shows,or as a DMX output device controlled by another server with an e:net connection. It is programmed using a PC or the LightingControl Engine running the software suite. One compact Butler controls up to 1024 DMX channels in two DMX universes. Up to 99 cue-lists for shows in standalone mode are stored on a micro SD card/ USB Interface. The DMX channel control can be increased to 16,384 channels by clustering more Butler S2s. The Butler should be powered by an external power supply with 12 to 24 V DC or via 48 V DC PoE (Power over Ethernet). A 7-segment LED is used for message and status display. It shall be supplied with PSU (Power Supply Unit) Two DMX universes (up to 1024 DMX channels) Scalable up to 16,384 channels (16 Butler S2, 32 universes) Can play up to 99 cue lists in standalone mode Plays up to eight cue lists in parallel Micro-SDHC drive for flexible storage Control of up to 128DMX universes when clustered using a central controller RJ45 connectivity for show upload, DMX output and e:net Standalone configuration via web browser on Ethernet interface Power consumption 2.7 W (incl. DMX termination) Operating/storage temp. 0 … 40 °C/32 … 104 °F Operating/storage humidity 0 … 80% non-condensing With Mounting Desktop or in Butler Garage CE Certified Conforms to UL
122Supply, Errection, Testing & Commissioning of RDM ISOLATOR (Repeater) Including Plug-in PSU 12V 2A Worldwide
123Bollards Bollard LED fittings mounted on 60 cms high rotomoulded LLDPE pillar duly grouted on a concretebase by means of four nos of M8 X 75 mm studs with necessary basering, (b) 15 W,1275 Lumens, Surge -4KV
124SETC of IP65 High Power LED Strip, 7.2 W/Mtr, As per Detail Technical Specification.
125Supply, Erecting, Testing, Commissioning & Programmingof Data supply units (Signal Booster/Repeater/Data Injector) for data-power feed to lighting fixtures as per detail technical specification.
126Supply installation testing and commisioning of a pillar feeder for street light as per details and specoitation approved by EIC with Provision of timer for controllinglight fixture
127Providing of External Electrification installation
128Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
129100 A, 10 kA,TPMCCB
130RISING MAINS & BUS TRUNKING
131Providing anf Fixing ( Following rating and breaking capacity) MCCB in esisting cubicle panel board including drilling holes in cubicle panel & making connection as reqd.
132125 A, Isc = 25 kA for 1 second
133Providing and fixing 125 amp TPN stand ground on load change over switch (Compact design)415/500 V including connectionetc as reqd
134S/F Bus bar chamber with 4 strips copper bus bar of length 300mm suitable for 200 amp capacity complete with all accessories i/c connection earthing the body etc as reqd
135EARTHING
136Earthing with copper earth plate 600 mm X 600 mm X 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. without charcoal/ coke and salt) as required.
137Extra for using salt and charcoal for GI or copper plate earth electrode as reqd
138Providing and Fixing 4mm dia copper wire on surface or in recessed for loop earthing as reqd
139CHAPTER 7-MV CABLE LAYING
140Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
141Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
142Additional Items
143Laying and fixing of 1 no.PVC onsulated PVC sheathed power cable of 1.1KV grade of size not less than 25 sqmm but not exceeding 120sqmm on surface as reqd.
144Supply of 125 KVA 3 Phase Diesel Generator including installation.Make-Kirloskar,Cummins,Jackson or Equivalent.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail