Public Administrative Department Local Bodies Closing in 0 days TDR #37758059

Tender For Detailed Project Report For Improvements To Water Supply Systemin Unnnamalaikadai Town Panchayat

Issued by Local Bodies · unnamalaikadai, Tamil Nadu
Tender Value
19.95 Crore
Estimated cost
Bid Submission
14 Jun 2023
0 days left
EMD
19.95 Lakhs
Bank guarantee accepted
Document Fee
25000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
unnamalaikadai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Detailed Project Report For Improvements To Water Supply Systemin Unnnamalaikadai Town Panchayat

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 28-May-2023 Payment method changed Other 06-Jun-2023
2 01-Jun-2023 Date Extended Date 14-Jun-2023

BOQ

Name of Work: Detailed Project Report for improvements to water supply systemin Unnnamalaikadai Town Panchayat
Sl. No. Item Description
1Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers. Sand, silt or other loose soil, wet sand or silt not under water light black cotton soil, sandy loam and ordinary soil.SS20B(TWAD SOR 22-23, Pg 295,296)
2Pumping Main
3110mm
4Feeder Main
590mm
6Distribution System
7250mm
8200mm
9160mm
10140mm
11110mm
1290mm
13Supply & delivery of following sizes of HDPE PIPES confirming to IS 4984/2016 (TWAD SOR 22-23, PN6, Pg 29 , )
14Pumping Main
15110mm
16Feeder Main
1790mm
18Distribution System
19250mm
20200mm
21160mm
22140mm
23110mm
2490mm
25Lowering HDPE pipes and specials to trench and layingtopropergradeandalignment andas directed by the TWAD Officers (TWAD SOR 22-23, Pg 268, 258)
26Pumping Main
27110mm
28Feeder Main
2990mm
30Distribution System
31250mm
32200mm
33160mm
34140mm
35110mm
3690mm
37Jointing HDPE Pipes and Specials by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed by TWAD Board Officers. (TWAD SOR 2022-2023, Pg 279, 261)
38Pumping Main
39110mm
40Feeder Main
4190mm
42Distribution System
43250mm
44200mm
45160mm
46140mm
47110mm
4890mm
49Supply , delivery and fixing of HDPE Pipe specials as per IS 8360/1977/Part I at site etc., complete as directed by Engineer in charge.(pg-32)
50Pumping Main
51110mm
52Feeder Main
5390mm
54Distribution System
55Equal tees (pg 32)
56250mm
57200mm
58160mm
59140mm
60110mm
6190mm
62Bends (pg 32)
63250mm
64200mm
65160mm
66140mm
67110mm
6890mm
69End Caps
70250mm
71200mm
72160mm
73140mm
74110mm
7590mm
76Barricading work (Where the lines are in narrow width of municipality area, busy streets like Market, Bus-stand and in the Highways etc.) for laying of pipe line using casurina poles at 1.50m center to center (8cm to 10cm dia. and 1.80m height) vertical with horizontal poles in two rows, painting the vertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including supplying, delivery and fixing of GI sheet (0.90m x 0.8mm thick) in the horizontal poles and fixing 75mm dia. reflectors including earth work excavation for fixing vertical posts and finally removing and stacking the materials safely for further use etc., complete and as directed by TWAD Board officers. (TWAD SOR 22-23, Pg 323)
77Pumping Main
78Feeder Main
79Distribution System
80Total
81Barricading work (Where, there is less traffic areas and broader roads etc.) for laying of pipe line using casurina poles at 1.50m center to center (8cm to 10cm dia and 1.80m height) vertical with horizontal poles in three rows including painting the vertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including fixing charges and fixing 75mm dia reflectors including earth work excavation for fixing vertical posts and finally removing and stacking the materials safely for further use etc., complete and as directed by TWAD SOR 22-23. (TWAD SOR 22-23, Pg 323)
82Pumping Main
83Feeder Main
84Distribution System
85Total
86Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and Eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification - Block for resting Duckfoot Bend
87Pumping Main
88Feeder Main
89Road Restoration
90Sump 1.00 LL
911.5 OHT-Upto 1.5m below GL
92Total
931.5 OHT-1.5m to 4.5m below GL
94Supplydelivery to site, fixing & Commisioningof kinetic air valve for handling more volumes of air in pumping main, double orifice kinetic air valve confirming to IS 14845 tamper proof design (PN-1) and with 6 years warranty including loading and unloading at site, transporting charges taxes and duties etc., as directed by the engineers of the following sizes. (TWAD SOR 22-23, Pg 68)
9550mm Double Air Valve
96Pumping Main
97Feeder Main
98Construction of chamber for sluice valve, scour valve & air valve usingsecond class chamber bricks in cement mortar 1:5and necessary plastering with cement mortar 1:3 for 12 mminside , precast concrete covers including reinforcement grill as per drawing , as per IS specifications and as directed by the engineers for the following sizes in metres,as per drawing.
99Size - 1.85m x 1.30m x 1.20m
100Pumping Main
101Feeder Main
102Refilling the trenches with excavated earth (other than sand) in layers and watering, ramming and consolidation as per standard specification etc complete and as directed by Engineer in charge (TWAD SOR 22-23, Pg 295,296)
103Pumping Main
104110mm
105Feeder Main
10690mm
107Distribution System
108250mm
109200mm
110160mm
111140mm
112110mm
11390mm
114Disposal of surplus earth including loading, conveyance within a distanceof5 km and spreading as directedbythe Engineer in charge. (TWAD SOR 22-23, Pg 322)
115Pumping Main
116Feeder Main
117Distribution System
118Labour charges for cutting of B.T road for laying of mains and as directed byEngineer in charge. (TWAD SOR 22-23, Pg 299)
119Pumping Main
120Feeder Main
121Distribution System
122Labour charges for cutting of C.C. road for laying of mains and as directed byEngineer in charge. (TWAD SOR 22-23, Pg 299)
123Pumping Main
124Feeder Main
125Distribution System
126Total
127Testing of pipes for water supply with hydraulic testingequipment by filling with water (including cost of water) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc., complete for the following diametres of pipes. (TWAD SOR 2022-2023, Pg 270)
128Pumping Main
129110mm
130Feeder Main
13190mm
132Distribution System
133250mm
134200mm
135160mm
136140mm
137110mm
13890mm
139Provision for Orifices for maintaining pressure
140Plain Cement Concrete 1:2:4 (one cement, two Crushed Stone Sand (M- Sand) and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour chargesetc., complete as per standard specification
141Providing House service connection with MDPE 20mm pipe (supply, lowering, jointing & testing), electrofusion tapping saddle PE 80 blue, PN 12.5 with female threaded metal insert of SS 304, brass ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and the corresponding bore sizes of 15mm dia size (1/2\"), Poly Propylene compression male threaded adaptor with metal insert of SS 304, Poly Propylene 90 degree compression elbow with compression joint at both ends, Poly Propylene compression female threaded adaptor with metal insert of SS 304 and protection box of size 20cm X 30cm for fixing of water meter all as per standard including road cutting, replacement of utilities providing house service connection, refillin, retoration of roads/ drains testing etc complete with materials and specification as instructed by department officers.
142Supply, delivery of Brass Ferrule as per IS 319 grade of sizes 15mm, 20mm and 25mm size and threaded as per IS :554 BSPT, ISO:7- 1 to suit the corresponding bore sizes of 15mm dia size ( 1/2\", ) in the saddle Connection as per IS :554 BSPT, ISO:7-1 (TWAD SOR 2022-2023, Pg 53, S.No.3(i))
14320mm
144Supply, delivery of Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRCNSF LTD, UK suitable for 20mm, OD MDPE pipes (TWAD SOR 2022-2023, Pg 54, S.No.3(v))
14520mm
146Supply, delivery of Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm OD MDPE pipes (TWAD SOR 2021-2022, Pg 53, S.No.3(iii))
14720mm
148Supply, delivery Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 20mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm respectively. (TWAD SOR 2022-2023, Pg 54, S.No.3(iv))
14920mm
150Supply, delivery of MDPE PE 80 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRC-NSF LTD, UK (TWAD SOR 2022-2023, Pg 54, S.No.3(vi))
15120mm
152U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRCNSF LTD, UK,size : 20mm ODx1/2\"ID, 25mm ODX1/2\"ID and 32mm OD X 3/4\" ID (TWAD SOR 2022-2023, Pg 54, S.No.3(viii))
15320mm
154Supply and delivery of protection box of size 20cm x 30cm for fixing of Water Meter. The box should be rectangular base in construction and material of construction should be weather resistant polyethylene (PE) blue /black .Reinforcement rips should be provided at the walls of the box. Box should be at two components comprising body and lid. Lid should be press fitted to the body. No hinges should be used for opened /closed. Operation meter box should be provided with built in lock. The body as inlet and outlet windows to pass the pipe through suitable for use with pipes of sizes up to 1\" .Base of the box should be designed in such a way .That the box can be installed to the floor/wall using anchor Bolts / screws without grouting the entire base of the meter Box .Provision for fixing Name plate showing the name of the Department etc., complete and as directed by the Department Official (TWAD SOR 2021-2022, Pg 54, S.No.3(54))
155Supply and delivery of multi jet water meter with removal mechanism water merers confirming to ISO 4064 Class B or IS 779 standards with type test certificates for Routine Test, IP 68 Test certificates issued by FCRI/NABL Accredited Lab. The water meter shall have magnetic or mechanical drivers or shall ber versatile for installation in horizontal position. The meters shall be hydrodynamically or hydrostatically balanced. The runner, runner chamber, pointers of the meter shall be as per ISO 4064Class B Specification. Dry dial excavated counter housing fully protected against floodings ensuring easy reading in all climatic conditions. The meters shall be inferntial, Dry-Dial Type, Class B with Straight reading Cyclometer with inbuild filter basket, meter body shall be of Brass body confirming to DCB2 material specification and suitable for drinking water applications
15615mm
157Lowering MDPE pipes and specials to the trench and laying to proper grade and alignment, jointing with couplers with cement past etc complete for the pipes size upto 40mm dia OD MDPE Pipes (TWAD SOR 2022-2023, Pg 268)
15820mm
159Jointing MDPE Pipes and Specials by butt fusion weldiEng / electro fusion welding joints using fusion equipment as per ISO 21307- 2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per HDPErected by TWAD SOR 22-23. (TWAD SOR 2022-2023, Pg 279)
16020mm
161Supply, delivery and fixing of GI pipes for encasing in open drain including handling charges. etc complete as per standard specifications and as HDPE rected by the TWAD SOR 22-23 (TWAD SOR 2022-2023, Pg 40)
16225mm
163Refilling with excavated soil (other than sand complying with the standard specification for filling in foundation and basement(TWAD SOR 2022-2023, Pg 295)
164Labour for cutting open road for laying water mains or sewer.B.T. Roads (or) Maccadam road (TWAD SOR 2022-23, Pg 299)
165Labour charges for drilling, cutting, Threading and Fixing Ferrules in distribution pipes
16625mm
167Supply, delivery to site, fixing, & commissioning of CI Sluice valve, Pressure Reducing and flow limit control valve, Electromagnetic flow meter including specials C.I. D/F pipe, PVC Tail Piece with Flange, Bolt Nut & Rubber Insertion (exluding Valve Pit)
168100 mm Sluice Valve, 100mm Flow Control Valve, 100 mm Electromagnetic Flow meter in 110 mm HDPE PN6 main
169100 mm CI D/F Sluice Valve - 1 No.
170100 mm DI D/F Pressure Reducing and Flow Limit Control Valve - 1 No.
171100 mm D/F Full Bore Electromagnetic Flow Meter - 1 No.
172100 mm x 0.20 m C.I.D/F Pipe - 2Nos
173100 mm x 0.75 m C.I.D/F Pipe - 2Nos
174110 mm PVC Tailpiece with flange - 2 Nos.
175Surface box - 1 No.
176Bolt , Nut & Rubber insertion - 100mm - 8 Nos.
177150 mm Sluice Valve, 150 mm Flow Control Valve, 150 mm Electromagnetic Flow meter in 140 mm HDPE PN6 main
178150 mm CI D/F Sluice Valve - 1 No.
179150 mm DI D/F Pressure Reducing and Flow Limit Control Valve - 1 No.
180150 mm D/F Full Bore Electromagnetic Flow Meter - 1 No.
181150 mm x 0.30 m C.I.D/F Pipe-2 Nos
182150 mm x 0.75 m C.I.D/F Pipe-2 Nos
183140 mm PVC Tailpiece with flange - 2 Nos.
184Surface box - 1 No.
185Bolt , Nut & Rubber insertion - 150mm - 8 Nos.
186150mm Sluice Valve, 150mm Flow Control Valve, 150mm Electromagnetic Flow meter in 160 mm HDPE PN6 main
187150 mm CI D/F Sluice Valve - 1 No.
188150 mm DI D/F Pressure Reducing and Flow Limit Control Valve - 1 No.
189150 mm D/F Full Bore Electromagnetic Flow Meter - 1 No.
190150 mm x 0.30 m C.I.D/F Pipe - 2 Nos
191150 mm x 0.75 m C.I.D/F Pipe - 2 Nos
192160 mm PVC Tailpiece with flange -2 Nos.
193Surface box - 1 No.
194Bolt , Nut & Rubber insertion - 150mm - 8 Nos.
195200mm Sluice Valve, 200mm Flow Control Valve, 200mm Electromagnetic Flow meter in 200 mm HDPE PN6 main
196200 mm CI D/F Sluice Valve - 1 No.
197200 mm DI D/F Pressure Reducing and Flow Limit Control Valve - 1 No.
198200 mm D/F Full Bore Electromagnetic Flow Meter - 1 No.
199200 mm x 0.40 m C.I.D/F Pipe-2 Nos
200200 mm x 0.75 m C.I.D/F Pipe-2 Nos
201200 mm PVC Tailpiece with flange - 2 Nos.
202Surface box - 1 No
203Bolt , Nut & Rubber insertion - 200mm - 8 Nos.
204250mm Sluice Valve, 250mm Flow Control Valve, 250mm Electromagnetic Flow meter in 250 mm HDPE PN6 main
205250 mm CI D/F Sluice Valve - 1 No.
206250 mm DI D/F Pressure Reducing and Flow Limit Control Valve - 1 No.
207250 mm D/F Full Bore Electromagnetic Flow Meter - 1 No.
208250 mm x 0.50 m C.I.D/F Pipe-2 Nos
209250 mm x 0.75 m C.I.D/F Pipe-2 Nos
210250 mm PVC Tailpiece with flange - 2 Nos.
211Surface box - 1 No
212Bolt , Nut & Rubber insertion - 250mm - 8 Nos.
213Construction of chamber for District Metering Area usingsecond class chamber bricks in cement mortar 1:5and necessary plastering with cement mortar 1:3 for 12 mminside , precast concrete covers including reinforcement grill as per drawing , as per IS specifications and as directed by the engineers for the following sizes in metres,as per drawing.
214For 110mm Dia. HDPE Pipe -1.85m x 1.30m x 1.20m
215For 140mm Dia. HDPE Pipe - 2.27m x 1.30m x 1.20m
216For 160mm Dia. HDPE Pipe - 2.27m x 1.30m x 1.20m
217For 200mm Dia. HDPE Pipe -2.65m x 1.30m x 1.25m
218For 250mm Dia. HDPE Pipe - 3.10m x 1.30m x 1.35m
219Earthwork excavation above Water Level in light or sandyor clayey soil for infiltration well of 4.50 m dia (Internal) includinglevelling the site with an initial lead of 10m and as directed by the departmental officers -Excavation for Infiltration well for first depth of 2.00 m SOR.2022-23,pg 249 (Area=3.14x7.00 2 )/4 =38.50 m 2
220R.C.CM 30 Design mixusing20 mm and 10mm size H. B.G stone (machine crushed) including mixing concrete using mechanical mixer machine and vibrating with mechanical vibrator, but excluding cost of steel reinforcement, fabrication and placing the grills in postion and the cost of centering and strutting but including curing, finishing etc.,complete as directed by the TWAD Board Officers.
221Infilteration Well
2221.00 LLSump
223Above G.L
224Below GL & upto 1.5 m
2251.50 LL OHT
226Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 400 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m\") 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
227Upto 1.5m below GL
228From 1.5m to 4.5m below GL
229upto 4.5m above GL
2304.5m to 7.32m above GL
2317.32m to 10.98m above GL
23210.98m to 14.64m above GL
23314.64m to 18.3 m above GL
23418.3 to 21.96m above GL
235Sinking of infiltration well of 6.00 m internal diabelow water level including all incidental charges using special tools and plants such as air compressor, helmet etc., complete including bailing out water below pilasters level (SOR-2020-21)
236I depth of 2 m
237II depth of 2 m
238III depth of 2 m
239IV depth of 2 m
240V depth of 2 m
241Porous Concrete CC 1:4 (one cement ,four hard broken granite jelly of size 20mm) for steining of infiltration well excluding cost of centering but including curing etc complete and as directed by the TWAD Board Officers
242Brick work in CM 1:5 (one cement and five sand) using country bricksfor steining of 45 cm thick for infiltration wellincluding ,curing, etc., complete and as directed by TWAD Board Officers.
243Centering forplane surface or circular curved surfaces including strutting upto to required height using MS sheets of size 90cm x 60cm and BG 10 gauge stiffened with welded MS angle of size 25mm x 25 mm x 3mm laid over silver oak (Country Wood) joists of size 10cm x 6.5cm (Spaced at about 90cm centre to centre) and supported by causrina props of 10cm to 13cm dia. (Spaced at 75cm centre to centre) complying with standard specification as per TWAD Board Officers -including the cost of strutting shuttering and all labour charges at Different levels
244Infilteration Well
245For plane surface
246For curved surface
2471.00 LLSump
248Plain surface
249Curved surface
250Round column
2511.50 LL OHT
252Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
253Upto 3.30 M Below GL
254For Footing side
255Square column
256Circular column
257Upto 3.30 M above GL
258Plane surface
259Square column
260Circular column
2613.30 - 4.30M above GL
262Square column
263Circular column
264Plain surface
2654.30 - 5.30M above GL
266Square column
267Circular column
2685.30 - 6.30M above GL
269Square column
270Circular column
2716.30 - 7.30M above GL
272Square column
273Circular column
274Plain surface
2757.30 - 8.30M above GL
276Square column
277Circular column
2788.30 - 9.30M above GL
279Square column
280Circular column
2819.30 - 10.30M above GL
282Square column
283Circular column
28410.30 - 11.30M above GL
285Square column
286Circular column
287Plain surface
28811.30 - 12.30M above GL
289Square column
290Circular column
29112.30 - 13.30M above GL
292Square column
293Circular column
29413.30 - 14.30M above GL
295Square column
296Circular column
29714.30 - 15.3 M above GL
298Square column
299Circular column
300Curved surface
30115.3 - 16.3 M above GL
302Square column
303Circular column
304Inside the tank
305From 0m to 3.3 m from floor slab
306Curved surface
307Circular column
308From3.3m to 4.3 m from floor slab
309Curved surface
310Plane surface
311Supply, delivery fabrication and placing in position of RTS rods for reinforcement for binding ring, pilasters, roof slab and well curb including cost of binding wire and as directed by TWAD Board officers.
312Infilteration Well
313Sump 1.00 LL
3141.5 LL OHT
315Plastering inside of well steining by CM 1:4 (One cement and four sand ) 12mm thick including curing etc., complete and as directed by TWAD Board Officers.
316Plastering outside of well steining by CM 1:5 (One cement and fivesand ) 20 mm thick including curing etc.,complete and as directed by TWAD BoardOfficers.
317Supply, delivery and fixing in position 50mm thick RCC manhole cover slab of size 0.60x0.60m with necessary reinforcement and MS angle of size 50mmx50mm x 12.5mm thick fixed alround the edges of the slab complete and as directed by the TWAD Board Officers.
318Infilteration Well
3191.00 LLSump
3201.50 LL OHT
321Supply, delivery and fixing of PVC moulded CI steps in position at 30 cm center to center in zig zag manner and as directed bythe TWAD Board Officers.
322ProvidingGIventilating arrangementof size 0.10m and as directed by the TWAD Board officers
323Labour charges for putting bore holes of size 3\" to 4\" in river bed in sandy and other loose soils using hand boring sets including the cost of hire charges, conveyance charges of hand boring sets,and complete as directed by TWAD Board Officers.
324Providing for cutting edge using 12G MS sheets including the cost of fabrication welding and placing in position in the curb including supply of the MS sheet with necessary holding rod of 20mm dia.
325Painting two coats with approved cement paint over one coat of primer over the cement plastered exposed wall surface and side of roof slab and complete as directed by TWAD board Officers
326Infilteration Well
3271.50 LL OHT
3281.00 LLSump
329Total
330Plugging the bottom of the well with coarse sand of approved sizes and grade as directed by the Board officers
331Earth work excavationand depositing on bank with an initial lead of 10m and initial lift of 2mfor foundation including shoring, strutting wherever necessary including hand bailing out water and all other incidental charges. etc. complete as directed by TWAD Board Officers as detailed below.
332hard stiff clay, stiff black cotton soil, hard red earth , shales, murams,gravel, stoney earth and earth mixedwith small boulders and hard gravelly soil
333First depth of 2 m
334Sump 1.00 LL
3351.50 LL OHT
336Supply and filling the foundation with clean river sand in layers, of not exceeding 15 CM thick complying with standard specification including consolidation and watering etc complete as directed by TWAD Board Officers.
337Sump 1.00 LL
3381.50 LL OHT
339Levelling course with plain cement concrete 1:4:8 (One cement, four sand and eight course aggregate) using 40mm size hard granite broken stone for foundation including mixing concrete laying, consolidation, curing etc. complete as directed by TWAD Board Officers
340Supply and fixing of GI cowls
341Supplying and fixing RCC ladderinside the sump
3421.00 LL Sump
3431.50 LL OHT
344Supplying and fixingMSladderout sidethe sump
345Providing cut stone set in C.M 1:3 for inlet pipe.
3461.50 LL OHT
3471.00 LL Sump
348Refilling the outside of the sump with excavated earth(other then sand) complying with standard specification for filling the foundation including watering consolidation etc., complete as directed by the TWAD Board Officers.
349Sump 1.00 LL
3501.50 LL OHT
351Earthwork excavation and depositing on bank for foundation,with an initial lead of10m and initial lift of 2m including shoring, struttingand all other incidental works, as directed by the departmental Officers in the following classification of soil. Hard stiff clay, stiff black cotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small sized boulders.
352Second Depth 2m - 3m below GL
353Earthwork excavation and depositing on bank with an initial lead of 10 meters and initial lift of 2 meters in Medium rock and dense medium rock not requiring blasting.(2m-3m below G.L)
354Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.(Contractor has to make his own arrangements for the supply of steel and binding wire)
355Refilling with excavated earth other than crushed stone sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officersin layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
356Supply and fixing of M20 design mix RCC hand rails of 0.9 m height over the top of the roof slab of approved pattern and design including the cost of cement, reinforcement, centering, precasting, finishing, curing cement painting the surfaces etc., complete and as directed by the TWAD Board Officers.
357a)Construction of RCC Spiral stair case in RCC M20 design mix concreteof 2.30m dia of required height for approach to the roof of Service Reservoir with RCC hand rails as per type design No.Sanitary Engineer/PH(M) NO.18/64 - 65 Sanitary Engineer(PH) 3/64 including necessary earth work excavation in various classification of soils met with at the site of work for providing foundation concrete in CC 1:4:8 mix, RCC footing M30 mix,GLplatform etc., including cost of steel reinforcement, fabrication charges, scaffolding, centering precasting charges, cement painting the surfaces etc.,complete and as directed by the TWAD Board Officers.The staircase shall be braced to the column of Service Reservoir at suitable interval
358Supply and fixing in position ventilator of reinforcement cement concreteRCC M20 design mix50 CM wide/diametre of approved pattern and design including cost of cement, reinforcement centering, shuttering, strutting, curing and fixing in position on the roof slab with mosquito proof net arrangement etc., complete. and as directed by the TWAD Board Officers.
359Providing pipe connection by lifting pipes and specials in vertical direction and placing the same for required alignment including lifting the pipes and specials in various heights of inlet, outlet, overflow and scour including earthwork excavation conveying the pipe and specials into the trenches, laying to proper grade and alignment cutting, threading and jointing with jointing materials with required specification including labour charges and supply of valves pipes, specials MS Clamps to fix the pipes with the columns including all taxes duties and connected charges etc. complete and taxes duties and connected charges etc. complete and as directed by Engineer in charge.
360Inlet
361Lifting and positioning of C.I / G.I / DI/ MS Pipes in vertical direction for service reservoir pipe connection - 150mm (TWAD SOR 2022-2023, Pg 300)
362Supply and delivery of 150 CI Pipe for plumbing2m - 21m (TWAD SOR 2022-2023, Pg 37)
363Supply and delivery of 150mm CIPipe for plumbing1m -1 No (TWAD SOR 2022-2023, Pg 37)
364150 mm CID/F SLUICE VALVE - 1 No (TWAD SOR 2022-2023, Pg 71)
365150 mm CI 90 DEG D/F BEND - 3 Nos (TWAD SOR 2022-2023, Pg 71)
366150 mm CI Flanged socket - 1 No (TWAD SOR 2022-2023, Pg 39)
367150 mm CI DUCKFOOTFLANGED BEND - 1 No(TWAD SOR 2022-2023, Pg 39)
368JointingCIpipes - 10 Nos (TWAD SOR 2022-2023, Pg 261,262, Item No. 8b)
369Providing MS clamp set to fix the inlet Pipewith column - LS
370Outlet
371Lifting and positioning of C.I / G.I / DI/ MS Pipes in vertical direction for service reservoir pipe connection - 150mm (TWAD SOR 2022-2023, Pg 300)
372Supply and delivery of 150 CI Pipe for plumbing2m - 18m (TWAD SOR 2022-2023, Pg 37)
373Supply and delivery of 150mm CIPipe for plumbing1m -1 No (TWAD SOR 2022-2023, Pg 37)
374150 mm CI 90 DEG D/F BEND - 1 Nos (TWAD SOR 2022-2023, Pg 71)
375150 mm CI Flanged socket - 1 No (TWAD SOR 2022-2023, Pg 39)
376150 mm CI DUCKFOOTFLANGED BEND - 1 No(TWAD SOR 2022-2023, Pg 39)
377JointingCIpipes - 11 Nos (TWAD SOR 2022-2023, Pg 261,262, Item No. 8b)
378Providing MS clamp set to fix the inlet Pipewith column - LS
379Scour
380Lifting and positioning of C.I / G.I / DI/ MS Pipes in vertical direction for service reservoir pipe connection -100mm (TWAD SOR 2022-2023, Pg 300)
381Supply and delivery of 100 CI Pipe for plumbing2m - 18m (TWAD SOR 2022-2023, Pg 37)
382Supply and delivery of 100mm CIPipe for plumbing1m -1 No (TWAD SOR 2022-2023, Pg 37)
383100 mm CID/F SLUICE VALVE - 1 No (TWAD SOR 2022-2023, Pg 71)
384100 mm CI DUCKFOOTFLANGED BEND - 1 No(TWAD SOR 2022-2023, Pg 39)
385100 mm CI Flange Scoket - 1 No(TWAD SOR 2022-2023, Pg 39)
386JointingCIpipes - 8 Nos (TWAD SOR 2022-2023, Pg 261,262, Item No. 8b)
387Providing MS clamp set to fix the inlet Pipewith column - LS
388Overflow
389Lifting and positioning of C.I / G.I / DI/ MS Pipes in vertical direction for service reservoir pipe connection -100mm (TWAD SOR 2022-2023, Pg 300)
390Supply and delivery of100mm CIPipe for plumbing2m (TWAD SOR 2022-2023, Pg 300)
391100 mm CI 90 DEG D/F BEND - 3 Nos (TWAD SOR 2022-2023, Pg 71)
392100 mm CI DUCKFOOTFLANGED BEND - 1 No(TWAD SOR 2022-2023, Pg 39)
393100 mm CI Flanged socket - 1 No (TWAD SOR 2022-2023, Pg 39)
394JointingCIpipes - 10 Nos (TWAD SOR 2022-2023, Pg 261,262, Item No. 8b)
395Providing MS clamp set to fix the inlet Pipewith column - LS
396Labourcharges for painting Department Emblem in accordance with the size and specifications as approved by the Board on the Service Reservoirs including cost of all consumables etc., complete and as directed by TWAD SOR 22-23.
397Supply, delivery and fixing in position of enamel coated \"water level indicator\" with all accessories of approved pattern and design, in the outer surface of the side wall of Sump to read the water level of the required height and as directed by TWAD Board Officers.
398pumpset
399Supply and delivery of Open well Submersible pump set conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller, CI FG 200 grade casing and brass screws and rotor shall be of copper rod as per IS 613/1984 with ISI mark. The pump suitable for installation in sump with 1.1KV grade 3 core suitable copper flat submersible cable to a length of 15m with necessary cable joints. The non-return valve located at the top of the pump in the discharge outlet connection is to be designed with minimum friction. The pump should be directly coupled to 2880 RPM, three phase, 50 Hz (±5), 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL upto 5 HP, Fully Automatic Air break Star Delta up to 20 HP and Auto Transformer starter for above 20 HP starting and for continuous operation.
400Wet Well
401600 lpm x 75 m
402Supply and delivery of floor mounting cubical type vermin and dust proof powder coated M.V. panel board made of 14 SWG MS sheet & MS angleironframe work with enclosed 4 Nos of Aluminium bus bar of Electrolyte grade E.91,PVC sleeved of suitable size for phase and netural with hinged front door and railway type lock and key arrangements.The bus bar shall be of ample current carrying capacity with all interal wiring as per IE rules and as per IS 8633 and as per safty requirements of CEIG. The desgin of panel board should facilitate for quick operation of all switches from the front side. The panel board shouldbe completed with all interal wiring including necessarytwin copper earthing arrangements and consists of the componets for controlling incoming and out going supply ; rate inclusive of fabrication charges
403INCOMING
404i)250 Amps, 3 phase 4poleMCCBwith over /under voltage release and short circut release to control the incoming supply to the bus bar in the cubical board from the E.B.supply point. - (1 No Spare)
405ii)Multi Functions Meters - Flush type for M V Panel Board - LED type, CT/PT, Voltage, Current, Frequency, Kilowatt, Kilo Volt Ampere, KVAR , KVAH, Run Hours, unbalance(V,A), Rpm, Phase angles, Thd - Class 0.5 With RS 485 Port (SOR )
406Outgoing
407i)200Amp 3phase MCCB ,TPN for controlling SD starter for HSC pumpset (1 no stand by)
408iI) 50Amp 3 phase3PMCCB to control the capacitor for HSCpumpset ( 1 NO spare)
409iii) 32 Amp 3Phase MCCB for controlling the lighting load of the pumproom
410iv) RYB & ON/OFF indicating lamps with control switch
411Supply and delivery of wall mounted cubical type EB meter Box Up to 50HP/37 KW (which includes LT meter panel board, 6 Nos. suitable fuse carriers SoR 2022-23 Pg.No125
412150mm dia Pressure Gauge and Vaccum guage including all accessories as per specification (For Suction and Delivery to be mounted on wall on Teak Wood Board) SoR 2022-23 Pg:123
413a)supply and delivery of heavy duty 1.1 KV grade 3.5x 95sq.mm-armoured aluminium conductor XLPE insulated pvc sheathed cable as per IS 7098 (Part I) to be laid in between EB pole - Meter Box - M.V. panelSoR 2022-23Pg.No:120
414b) Layingthe above cable as per IE rules inside the pumproom or in air SoR 2022-23Pg.No122
415c)Jointing of the above L.T. cables 3.5 core 1.1 KV grade Armoured Aluminium conductor cable confirming to IS7098 Part I with ISI markingincluding jointing materials lugs,clamps,etc., SoR 2022-23 Pg.No:125
416a)Supply and delivery of heavy duty 11 KV grade 3.5x50 sq.mm-armoured aluminium conductor XLPE insulated pvc sheathed cable as per IS 7098 (Part I) to be laid in betweenM.V. panelto ATSstarter for 50HPHSCSoR 2022-23Pg.No:123
417b) Layingthe above cable as per IE rules inside the pumproomSoR 2022-23Pg.No127
418c)Jointing of the above L.T. cables 3.5 core 1.1 KV grade Armoured Aluminium conductor cable confirming to IS7098 Part I with ISI marking including jointing materials lugs,clamps,etc., SoR 2022-23 Pg.No:125
419a)Supply and delivery of heavy duty 1.1 KV grade 3x 50sq.mm-armoured aluminium conductor XLPE insulated pvc sheathed cable as per IS 7098 (Part I) to be laid in from ATSstarter to motor for 50 HP HSC pumpset SoR 2022-23Pg.No:123
420b) Layingthe above cable as per IE rules inside the pumproomSoR 2022-23Pg.No127
421c)Jointing of the above L.T. cables 3 core 1.1 KV grade Armoured Aluminium conductor cable confirming to IS1554 Part I with ISI markingincluding jointing materials lugs,clamps,etc., SoR 2022-23 Pg.No:125
422a)Supply and delivery of heavy duty 11 KV grade 3x 16 sq.mm-armoured aluminium conductor XLPE insulated pvc sheathed cable as per IS 7098 (Part I) to be laid in from M.V. panelto 18 KVAR capacitor
423b) Layingthe above cable as per IE rules inside the pumproomSoR 2022-23Pg.No127
424c)Jointing of the above L.T. cables 3core 1.1 KV grade Armoured Aluminium conductor cable confirming to IS1554 Part I with ISI marking including jointing materials lugs,clamps,etc., SoR 2022-23 Pg.No:125
425Supply, Deliveryand Fixing of the following items for obtaining Service Connection from E.B.Pole.
426150 mm GI SERVICE PIPE to a length of 3m
427150mm GI bend-3Nos
428150mm GI Coupling-3Nos
429Providing pump housewiring and lighting arrangements.
430Providing pump house lighting wiring using PVC conduit pipes and specials with 2 runs 1.5 sq mm PVC insulated copper wire and 1 run14 SWG TC wire for earthing for lights, 5 Amps plug points includingswitch box 5 Amps switch socket, celing rose and consumable suitable for pump house wiring
431Supply and fixing LED INDOOR FITTINGS (LIGHT EMITTING DIODE)24W LED 4000K 2 x 2 Square Type Recessed Fitting (vide page194 of SR Book 2022-23 )
432Supply and fixing LED OUTDOOR FITTINGS (LIGHT EMITTING DIODE)30W LED Street Light Fitting
43316 amps.3 pinflush type wall socket only.-3No SoR 2022-23 pg 203
434Supply and delivery of safety appliances as detailed below SoR 2022-23 Pg.No:131 item 18
435Electrical gloves tested to 11 KV /22 KVwith wooden box dusted with french chalk powder -2Nos
436Electrical quality 6mm thick rubber mat - 6 Nos
4375 kg capacity ISI marked Dry chemical powder fire extinguisher - 2 Nno
438Fire Bucket-3 Nos Hooked to MS stand -1 No
439Laminated shock treatment chart - 2 NO
440Wooden First Aid Box -1 no
441ProvidingthefollowingtoolsmountedonTeak woodBoardtobefixedonthewall and in a teak wood box SoR 2022-23 pg:133
442Connector Screw Driver 901 Taparia Make or equivalent - 1No
443200mm Screw Driver 825 Taparia Make or equivalent -1No
444200mm Cutting PlierTaparia Make or equivalent -1No
445800gm Ball Pane Hammer with HandleTaparia Make-1No
446DE Spanner set 6 to 32 Jhalani Make or equivalent
447Twin CI Earthing as per IS 3043/1987 and I.E. rules including Earth pit (2 pits) with RCC slab and other civil works complete (upto 25 HP) (SOR 22-23/ Item 19.0/ P. 127)
448Labour Charges for erection of Horizontal shaft, centrifugal pumpset (Coupled/Monoblock) in bore well/Open well including fixing of suction pipe and foot valve upto a maximum depth of 7 metres and delivery pipes to the required length with valves, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPIC switches starter, Voltmeter, Ammeter, Capacitor single phasing preventor and laying and jointing the cables and twin earthing as per IE rules including providing bed blocks etc., complete and operating the pumps and trial run for 10 days including signing of completion of reports as required by EB authorities. SoR 2022-23 Pg.No:307
4495HP pumpset
450Supply and delivery of CI D/F200mm Non returnvalve wafer type ( dual plate check valve) to be used in pump houses confirming to IS
451Supply and delivery of CI D/F 200 mm sluice valve with spur gear and hand operation ISI mark reputed make PN 1.6 to be used in pump houses( Long body/long face to face) confirming to IS (12.5)(SOR -P- 68)
452Supply and delivery of CI D/F 250 mm sluice valve with spur gear and hand operation ISI mark reputed make PN 1.6 to be used in pump houses( Long body/long face to face) confirming to IS (12.5)(SOR -P- 68)
453Supply and delivery of CI D/Fsluice valve with cap wheel as pe IS 14846/2000 PN 1.0 with ISI marking . The rates are inclusive of transportation charges, etc., (SOR -P- 65)
454250 mm sluice valve - for 250mm main
455Supply and delivery of CI D/F200mm Non returnvalve wafer type ( dual plate check valve) to be used in pump houses confirming to IS
456250mm Non return valve - for 250mm main
457Supply and delivery of following CI pipe and spls. IS 1538/1993 , IS 7181/1986 & IS 1537/1996(SOR -P- 39)
458For suction
459upto 250 mm CI D/F spls
460250x150mm CI D/F Tapper
461250mm CI D/F bend
462250mm CI Foot valve
463Upto 250mm CI D/F pipe
464250mmx 1.00m CI D/F pipe
465250mm x 2.75m CI D/F pipe
466Delivery pipe
467Upto 200mm CI D/F spls
468125 x 200mm CI D/F Tee
469200mm CI D/F bend
470200mm CI D/F duckfoot Bend
471upto 250 mm CI D/F spls
472200x250mm CI D/F Tapper
473Upto 200mm CI D/F pipe
474200mmx 0.50m CI D/F pipe
475200mmx 0.50m CI D/F pipe
476200mmx 1.00m CI D/F pipe
477200mmx 2m CI D/F pipe
478200mmx 2.5m CI D/F pipe
479200mm x 2.75m CI D/F pipe
480Jointing the C.I/ D.I Double flanged pipes and specials with rubber insertion to the required specificationwith M.S. bolts and nutscomplete (including cost of jointing materials) SoR 2022-23 Pg.262
481200mm
482250mm
483Supplyand deliveryofWoltman model with removal mechanism water meters of following sizes with Dirt box confirming toIS 2373 with life cycle test certificate from FCRI/NABl Accredited lab.The water meters shall have magnetic drivers or mechanical drivers and shall beversatile for installation in any position.Themeters shall be hydro dynamiacally ,hydrostaticallybalanced. The runner,runner chamber, pointers of the meter shall be as per ISO 4064 Class B specification.Dry dial excavatedcounter housing fully protected against flooding ensuring easy reading in all climates.**** PAYMENTS ONLY MADE AFTER RECEIPT OF TEST CERTIFICATES FOR THE DELIVERED MATERIAL FULFILL ALL THE TEST PARAMETERSSoR 2022-23 pg:86
484200mmwater meter with dirt box
485Erection of water meter including earth work excavation ,labour charges from cutting and threading, convenyance,welding and hire charges for tools and plants etc complete and as directed by the TWAD Board officers. SoR 2022-23 Pg:86
486200mmwater meter with dirt box
487Supply and run of 4 x 6 sq.mm. (84 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V on 7 / 20 GI bearer wire for service connection mains (SD68)

AI Tender Summary

OUR REF NO 37758059
AUTHORITY Local Bodies
TENDER VALUE 19.95 Crore
LAST DATE 14-06-2023
Authority
Authority Name Town Panchayats
Work Description Detailed Project Report For Improvements To Water Supply Systemin Unnnamalaikadai Town Panchayat
Basic Detail
Tender No 145/2022/A1
Bidding Type Tender
Location
City unnamalaikadai
State Tamil Nadu
Key Dates
Publish Date 01 Jun 2023
Submission Date 14 Jun 2023
Open Date 14 Jun 2023
Finance
Tender Value 19.95 Crore
Tender Fee 25000
EMD 19.95 Lakhs
Exemption Not Available
Document List
b3eecc54-eecf-4120-b571-3312276ef17b.html
Bid.pdf
BOQ_376212.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 01, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 06, 2023
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 14, 2023
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 14, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 14, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

b3eecc54-eecf-4120-b571-3312276ef17b.html

pdf

Bid.pdf

xls

BOQ_376212.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders