Tender For Supply Installation Testing And Commissioning And Repairing Of Valve Of Dewatering System In The Dam Gallery Of Vyasi Dam At Juddo Dehradun
Tender Value
16.74 Lakhs
Estimated cost
Bid Submission
10 Jun 2023
0 days left
EMD
50300
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Supply Installation Testing And Commissioning And Repairing Of Valve Of Dewatering System In The Dam Gallery Of Vyasi Dam At Juddo Dehradun
BOQ
| Sl. No. | Item Description |
| 1 | Supply part: |
| 2 | Supply of Cast steel Gate Valve Size 200 mm.(As per Technical specification)Make: Leader /L&T/Audco Valve Only.(Warranty of Valve 12 Months and After Sale Service for 5 Years) |
| 3 | Supply of Cast Steel NRV Valve Size: 200 mm .(As per Technical specification)Make : Leader /L&T/Audco Valve Only.(Warranty of Valve 12 Months and After Sale Service for 5 Years) |
| 4 | Supply of Cast steel Gate Valve Size 150 mm.(As per Technical specification) Make : Leader /L&T/Audco Valve Only.(Warranty of Valve 12 Months and After Sale Service for 5 Years) |
| 5 | Supply of Cast Steel NRV Valve Size: 150 mm.(As per Technical specification)Make : Leader /L&T/Audco Valve Only(Warranty of Valve 12 Months and After Sale Service for 5 Years) |
| 6 | Supply of Mild Steel Nut/Bolt set 10x65 “OR” (as per Sample) |
| 7 | Supply of Packing Sheet 3mm “OR” as per requirement. |
| 8 | WORKPART : |
| 9 | Making of Arrangement for Dismantling of (02 No of NRV Valve’s) and Installation of (03 No ofNRV Valves),(As per technical specification) |
| 10 | Dismantling of Cast Steel NRV Valve Size : 200 mm , Class —150from the dewatering pipe line.(as per technical specification) |
| 11 | Proper Installation and testing of New C.S NRV Valve Size 200 mm , Class – 150at the same place of dewatering pipe line (As per technical specification) |
| 12 | Proper Repairing and Overhauling of Old and damage, Rusted NRV Valve Size 200 mm .(As per technical specification) |
| 13 | Dismantling of Cast Steel NRV Valve Size : 150 mm , Class —150from the dewatering pipe line (As per technical specification) |
| 14 | Proper Installation and testing of New C.S NRV Valve Size 150 mm , Class – 150at the same place of dewatering pipe line.(As per Technical specification) |
| 15 | Making arrangement for installation of NRV and flange size 150MM in existing line (as per technical specification |
| 16 | Proper Repairing and Overhauling of Old and damage, Rusted NRV Valve Size 150 mm (As per technical specification). |
| 17 | Making of Arrangement for Dismantling and Installation of Gate Valves size 200 mm and 150 mm .(As per Technical specification) |
| 18 | Dismantling of Cast Steel Gate Valve Size : 200 mm , Class —150from the dewatering pipe line (as per technical specification) |
| 19 | Proper Installation and testing of New C.S Gate Valve Size 200 mm , Class – 150at the same place of dewatering pipe line (As per technical specification) |
| 20 | Proper Repairing and Overhauling of Old and damage, Rusted Gate Valve Size 200 mm (As per Technical specification.) |
| 21 | Making flange arrangement at the end of 8inch dia pipe line. (as per technical specification) |
| 22 | Dismantling of Cast Steel Gate Valve Size : 150 mm , Class —150from the dewatering pipe line.(As per technical specification) |
| 23 | Proper Installation and testing of New C.S Gate Valve Size 150 mm , Class – 150at the same place of dewatering pipe line .(As per technical specification) |
| 24 | Proper Repairing and Overhauling of Old and damage, Rusted Gate Valve Size 150 mm.(As per technical specification) |
| 25 | Cleaning of Dewatering sump/pit of size 5.5M X 4M X 4M including cleaning, lifting and disposal of mud and silt from wall and bottom of the pit by means of extra pumps and manual bucket including all consumable, T&P and labour. (as per technical specification) |
| 26 | Shifting of 03 no starter panel system of dewatering pump from near NRV to another suitable place as per site requirement |
| 27 | Proper Testing of all Welded Joints by using Dye Penetrant inspection Kit . |
| 28 | Shifting all Scrap from site to store (as per technical Specification) |
AI Tender Summary
Tender Timeline
May 19, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedJun 10, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJun 14, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender