Tender For Construction Of Ac Plant Room And Electrical Panel Room( Balance Work)At Kalamandal Project, Near Sainik School, Bhubaneswar, bhubaneswar-Odisha

Orissa Industrial Infrastructure Development Corporation-IDCO has published Tender For Construction Of Ac Plant Room And Electrical Panel Room( Balance Work)At Kalamandal Project, Near Sainik School, Bhubaneswar. Submission Date for this Tender is 05-06-2023. Electrical Panel Tenders in bhubaneswar Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

37752400
Corrigendum : Tender For Construction Of Ac Plant Room And Electrical Panel Room( Balance Work)At Kalamandal Project, Near Sainik School, Bhubaneswar
Open Tender
Indian
Odisha
bhubaneswar
05-06-2023

Tender Details

Construction Of Ac Plant Room And Electrical Panel Room( Balance Work)At Kalamandal Project, Near Sainik School, Bhubaneswar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-Jun-2023 Due Date Extended - Due to some issues in accessing portal, all the tenders due for closing on 02-June-2023 from 10.00 Hrs. to 18.55 Hrs have been extended by 72 hours as per System Malfunction Procedure. Admin Corrigendum Date Extend 05-06-2023

Key Value

Document Fees
INR 10000 /-
EMD
INR 65000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:Construction of AC Plant Room & Electrical Panel Room( Balance work)at Kalamandal Project, near Sainik School, Bhubaneswar
Sl. No. Item Description
1CIVIL WORK
2Earthwork in excavation upto 1.50mtr depth of foundation trenches for columns, basement, tie beams, walls and steps in following types of soil including moorum, hard stony earth, earth mixed with boulders, Laterite rocks etc but not requiring blasting with initial leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, design including cost of all labour, T&P etc. as required for the work completein all respectexcluding GST as directed by the Engineer- in- charge.
3In all kinds of soil
4In DI rock
5Earthwork in excavation beyond 1.50mtr depth of foundation trenches for columns, basement, tie beams, walls and steps in following types of soil including moorum, hard stony earth, earth mixed with boulders, Laterite rock etc but not requiring blasting with initial leads and lifts including dressing and leveling the bed sides up to required depth and depositing the excavated materials at places away from the work site with T&P for shoring, shuttering, dewatering if required etc. complete as per the drawing, designing including cost of all labour, T&P etc. required for the work completein all respectexcluding GST as directed by the Engineer- in- charge.
6In all kinds of soil
7In DI rock
8Filling foundation trenches and plinth with excavated earth including laying the earth in layers not exceeding 23.5cm (9”) thick ramming and watering with all leads and lifts including cost of all labour, T&P etc. complete as directed by the Engineer-in-charge.
9Supplying & Filling foundation trenches, plinth & ditches with river sand well watered and rammed inlayers not exceeding23 c.mindepthwith all lead and lift including cost, conveyance, loading, unloading,stacking,royaltiesof all Materials, cost of all Labour,Sundries, T&P required for the work complete in all respect excluding GST as directed by the Engineer-in-charge.(Measurement will be taken on finished compacted section only.)
10Providing & layingPlain Cement concrete (PCC )of proportion (1:3:6) in foundation and floors using 4cm (1½”) size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6”) thick to the required level ramming, watering, curing etc. complete including cost, conveyance , loading,unloading,royaltiesof all materials, cost of all labour, Sundries, T&Prequired for the work including shoring, shuttering and dewatering ( if required) including hire and running charges of water pumprequired for the workcomplete in all respect excluding GST as directed by the Engineer-in-charge.
11Providing ,Lifting, Hoisting & Laying Reinforced Cement Concrete ofM-25 for foundationas per approved designs and drawings having a minimum compressive strength ( in work test) 25 N/mm2 in 15 cm. cubes at28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips of approved quality from approved quarry, washed and cleanedto be mixed in concrete mixturewith approved quality of cementincluding hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, including cost of requiredcentering and shuttering thereafter dismantling and removing thedebrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessaryincluding cost, conveyance, loading, unloading,stacking, royaltiesof all materials, cost of all labours, scaffolding, sundries, T&P required for the work etc. completeinall respect butthe excluding cost &conveyanceof M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc.ofM.S. rods or Tor steel and binding wires and tying the grills and placing in proper position excluding GSTas directed by the Engineer-in-charge.having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills.
12R.C.C. work ofM-25 for plinth beam as per approved designs and drawings having a minimum compressive strength ( in work test) 25 N/mm2 in 15 cm. cubes at28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips of approved quality from approved quarry, washed and cleanedto be mixed in concrete mixturewith approved quality of cementincluding hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, including cost of requiredcentering and shuttering thereafter dismantling and removing thedebrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessaryincluding cost, conveyance, loading, unloading,stacking, royaltiesof all materials, cost of all labours, scaffolding, sundries, T&P required for the work etc. completeinall respect butthe excluding cost &conveyanceof M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc.ofM.S. rods or Tor steel and binding wires and tying the grills and placing in proper position excluding GSTas directed by the Engineer-in-charge.having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills.
13R.C.C. work ofM-25 for beam and column as per approved designs and drawings having a minimum compressive strength ( in work test) 25 N/mm2 in 15 cm. cubes at28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips of approved quality from approved quarry, washed and cleanedto be mixed in concrete mixturewith approved quality of cementincluding hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, including cost of requiredcentering and shuttering thereafter dismantling and removing thedebrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessaryincluding cost, conveyance, loading, unloading,stacking, royaltiesof all materials, cost of all labours, scaffolding, sundries, T&P required for the work etc. completeinall respect butthe excluding cost &conveyanceof M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc.ofM.S. rods or Tor steel and binding wires and tying the grills and placing in proper position excluding GSTas directed by the Engineer-in-charge.having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills.
14Ground Floor
15First Floor
16R.C.C. work ofM-25 for lintel as per approved designs and drawings having a minimum compressive strength ( in work test) 25 N/mm2 in 15 cm. cubes at28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips of approved quality from approved quarry, washed and cleanedto be mixed in concrete mixturewith approved quality of cementincluding hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, including cost of requiredcentering and shuttering thereafter dismantling and removing thedebrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessaryincluding cost, conveyance, loading, unloading,stacking, royaltiesof all materials, cost of all labours, scaffolding, sundries, T&P required for the work etc. completeinall respect butthe excluding cost &conveyanceof M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc.ofM.S. rods or Tor steel and binding wires and tying the grills and placing in proper position excluding GSTas directed by the Engineer-in-charge.having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills.
17R.C.C. work ofM-25 for roof slab at double height as per approved designs and drawings having a minimum compressive strength ( in work test) 25 N/mm2 in 15 cm. cubes at28 days after mixing and test conducted in accordance with I.S. 456 and I.S. 516 using screened & washed sharp river sand for mortar and 10 mm. to 20 mm. size black hard crusher broken granite stone chips of approved quality from approved quarry, washed and cleanedto be mixed in concrete mixturewith approved quality of cementincluding hoisting, lowering, laying and compacting concrete by using vibrators, watering and curing for 28 days, including cost of requiredcentering and shuttering thereafter dismantling and removing thedebrises away from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessaryincluding cost, conveyance, loading, unloading,stacking, royaltiesof all materials, cost of all labours, scaffolding, sundries, T&P required for the work etc. completeinall respect butthe excluding cost &conveyanceof M.S. rods or Tor Steel and Binding wires and labour charges for straightening, cutting, bending etc.ofM.S. rods or Tor steel and binding wires and tying the grills and placing in proper position excluding GSTas directed by the Engineer-in-charge.having minimum compressive strength of 250kg./cm2 in 15cm cubes at 28 days and in accordance with I.S. 456 and I.S. 516 using crusher broken hard black granite chips of approved quality & from approved quarry including hoisting, lowering, laying and compacting concrete with vibrator, watering and curing for 28 days, cost of rigid and smooth centering & shuttering and finishing to exposed surface smooth providing, grooves or beads wherever necessary including cost, conveyance, royalties of all materials and cost of all labour, T&P etc. as required for the work complete in all respects as per drawing, design and direction of Engineer-in-charge but excluding cost of M.S. rod/Tor steel and binding wires and labour charges for bending, binding and tying the grills.
18Providing & fixing Thermo mechanically treated bars (Fe-500 D) Reinforcement bars of approved makefor RCC work of required diameter& of approved quality including straightening, cutting, bending, binding, welding , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings with provision for fan hooks where required including the cost, conveyanceof reinforcement bars or tor steel and binding wires of 18 to 20 gauge, cost of all labour,loading, unloading, labour cess, T&P, etc. required for the work complete for the workin all heights as per the specification & excluding GST as direction of Engineer-in-Charge. (Linear measurements will be taken & quantity will be calculated on standard weight. Weight of binding wire will not be considered for measurement. No payment will be made for overlap, couplings, welded joints spacer bars,stays, hangers and wastage. Cost of these items shall be deemed to be included in the rates for reinforcement)
19Ground Floor
20First Floor
21Brick work in foundation and plinth with flyash bricks of size 25x12x8cm in cement mortar (1:6) with best quality bricks having crushing strength not less than 75 Kg/cm2 immersing the bricks in water for not less than 6 hours before use (the bricks shall be free from cracks, well shaped, uniform in size and shall produce a clear metallic ringing sound when struck) includes molding, chamfering, corbelling .complete as per drawing, design and specification, watering and curing for 7days including cost, coveyance,stacking, loading, unloading, royalties of all materials ,cost of all labour,scaffolding, sundries and T&P required for the workscomplete in all respect excluding GST as directed by the Engineer-in-charge.
22Brick work in superstructure with flyash bricks of size 25x12x8cm in cement mortar (1:6) with best quality bricks having crushing strength not less than 75 Kg/cm2 immersing the bricks in water for not less than 6 hours before use (the bricks shall be free from cracks, well shaped, uniform in size and shall produce a clear metallic ringing sound when struck) includes molding, chamfering, corbelling .complete as per drawing, design and specification, watering and curing for 7daysincluding cost, coveyance,stacking, loading, unloading, royalties of all materials ,cost of all labour,scaffolding, sundries and T&P required for the workscomplete in all respect excluding GST as directed by the Engineer-in-charge.
23Ground Floor
24First Floor
25Second Floor
2625 mm. average thick artificial stone flooring with cement punning laid to proper slope with cement concrete of proportion (1:2:4) using and with screened and washed sharp sand for mortar with black hard crusher broken granite stone chips of approved quality and from approved quarry, washed and cleaned laid in two layers i.e. the bottom layer being 19 mm . thick and top layer of 6mm. thick with 12mm. to 20. size black hard crusher brokenstone chips (20mm size chips not to exceed 25%) including chipping and chiseling and cleaning the top surface of the floor slabs in upper floors, including rounding of corners, watering and curingincluding cost, coveyance,stacking, loading, unloading, royalties of all materials ,cost of all labour,scaffolding, sundries and T&P required for the workscomplete in all respect excluding GST as directed by the Engineer-in-charge.
27Ground Floor
28Providing 12mm. thick cement plaster with cement mortar of mix (1:4) in all floors with Portlandslag cement (PSC) and with screened and washed sharp sand for mortar with neat cement punning finished smooth to brick/RCC walls after racking out the joints including watering and curing complete including cost, coveyance,stacking, loading, unloading, royalties of all materials ,cost of all labour,scaffolding, sundries and T&P required for the workscomplete in all respect excluding GST as directed by the Engineer-in-charge.
29Supplying, fitting and fixing in position 25mm thick cement concrete tile of approved make, quality, colour and size in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient grouted with neat white cement slurry with required quantities of pigments of approved marks watering and curing for 21 days, including cost, coveyance,stacking, loading, unloading, royalties of all materials ,cost of all labour,scaffolding, sundries and T&P required for the workscomplete in all respect excluding GST as directed by the Engineer-in-charge.
30Supplying, fitting and fixing of MS openable shutter with 35 x 35 x 6mm size M.S. angle frame as chowkath and 30x30x5mm Ms frame for shutter with 25x6mm flat fabricated to proper size of door opening with 16 gauge CR sheet including fixing clamps for door frames and hinges for fixing shutters and aldrop with tower bolt etc. complete for all floors including cost, conveyance,of all materials, labour, T&P etc.required for the work complete in all respect excluding GST as directed by the Engineer-in-charge.
31Providing and fixingrolling shutters of approved make, made of 80x1.25mm laths interlocked together through their entire length and jointed at the by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including thecost ofproviding and fixing necessary 27.5 cm long wire springs grade no 2. and M.S. top cover 1.25mm thick for rolling shutter. Item include providing and fixing 2 nos ball bearings ofapprovedmake in rolling shutter.Item also include painting of shutterwith 2 coats ofsynthetic enamel paint over a coat of metal primer of approved make & shade and fixing of shutter with lugs of 15x 6mm in 15cmx10cmx10cm cement concrete blocks of 1:2:4 (1cement:2 coarse sand:4 graded stone aggregate). The rate should include cost of all materials, labour ,T&P etc.required for the workcomplete in all respect excluding GST as directed by the Engineer-in-charge.
32Providing 25mm thick grading concrete in C.C. (1:2:2) laid in proper slope over terrace roof slab by using two part of sand, one part of cement and two parts of6mm size black hard crusher broken granite chips with addition of water proofing compound of approved quality to be mixed with specified ratio including watering, curing, cost, conveyance, royalties, of all materials, cost of all labour, T&Petc.required for the workcomplete in all respect excluding GST as directed by the Engineer-in-charge.
33First Floor
34Providing 12mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) finished smooth to outside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners etc. complete with cost, coveyance, loading and unloading, royaltiesof all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as desired by the Engineer in charge.
35Ground Floor
36First Floor
37Second Floor
38Providing 12mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) finished smooth to inside smooth surface of brick masonry walls after racking out the joints including watering and curing, rounding of corners etc. complete with cost, coveyance, loading and unloading, royalties and taxes of all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as desired by the Engineer in charge.
39Ground Floor
40First Floor
416 m.m thick cement plaster in cement mortar of mix (1:4)in all floors at all height using screened& washed sharpriver sandformortar with approved quality of cement tothe ceilingofthe Roof Slab, Staircase,Beams, Columns,Landings, Railings,Chajja ,Fins ,Walls ,Jallyand Shelves etc. including roughening, scraping, chiseling, cleaning, closed deep chipping with slurry treatment and finished smooth to allR.C.C. Surface including cost, conveyance, loading, unloading, royalties ,stackingof all Materials, cost of all Labour,Sundries, T&P, Scaffolding,Watering, Curing etc. complete in all respect excluding GST as directed by the Engineer- in- charge.
42First Floor
43Providing and painting the internal plastered surface with water proofing cement paint of approved quality and shade, in all floors at all height using required quantity of cement paint as specified by the manufacturer to give an even shade over a coat of cement wash with watering the surface before applying the cement paint and curing the surface for required days with cost, conveyance, loading, unloadingof all materials, cost of all labour, sundries, T & P, scaffolding, watering and curing etc. complete as directed by the Engineer-in-charge.
44Ground Floor
45First Floor
46Painting to external surface of building with two coats of weather coat over a coat of water based primer of approved shade and quality of approved design, after cleaning by watering & removing the dirts etc. to the surface to be painted including cost, coveyance, loading , unloading ,stackingof all Materials,cost of all Labour,Sundries, Staging,Scaffolding, T&P required for the work etc. complete in all respect excluding GST as per specification as directed by Engineer-in-charge.
47Ground Floor
48First Floor
49Second Floor
50Providing and painting two coats with synthetic enamel paint over a coat of zinc oxide primer of approved quality and approved shade confirmming to ISI on steel work to give an even shade in all floors at all height including sand papering and making the surface smooth including cost, coveyance, loading , unloading ,stackingof all Materials,cost of all Labour,Sundries, Staging,Scaffolding, T&P required for the work etc. complete in all respect excluding GST as per specification as directed by Engineer-in-charge.
51Ground Floor
52Providing and applying 2 coats of 1mm thick elastomeric cementitious waterproofing coating Brushbond RFX of Fosroc Chemicals Tested to ASTM D4060, ASTM D4541, ASTM D638, ASTM C836. with Adhesion to concrete : >1N/mm2for waterproofing structures like roof slabs, sunken slabs, chajjas, tunnels, water tank etc. after proper surface preparation and soaking the surface with water prior to application complete as specified and directed by the Department at all levels.
53Providing and fittingof circular/square/rectangular Structural steel work welded in built up sections forframed work including cutting,hoisting,fixing in position and applying a priming coat of approved steel primer etc.including cost, coveyance, loading , unloading ,stackingof all Materials,cost of all Labour,Sundries, Staging,Scaffolding, T&P required for the work etc. complete in all respect excluding GST as perthe approved drawing & designand as directed by Engineer-in-charge.
54Providing and lying plain cement concrete of (1:2:4) in foundation and floors using 12 mm. Size black hard crusher broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-Charge.
55Providing and fixing of GRC Column as per approved drawing & design including cost, coveyance, loading and unloading, royaltiesof all materials and cost of all labours, sundries, T&P and scaffolding required for the work etc. complete in all respect as desired by the Engineer in charge. B=1.10, T=0.90, 5.75 Mtr
56Providing and injecting chemical emulsion for pre - constructional antitermite treatment as per IS specification and creating a chemical barrier in bottom and sides of foundation trenches, top-surface of plinth filing junction of walls and floors along with external perimeter of the building expansion joints surrounding the pipes and cables etc. complete using approved quality of chemical emulsion of requisite quantity prescribed by the manufacturer as directed by the Engineer-in-charge including cost of all materials and labour taxes etc. complete. (Measurement should be taken as per plinth area and indemnity bond for warranty for 10 years to be furnished)
57Supplying all labour, T&P for the Carriage of excavated earth by mechanical means of transport within 5.00 K.M. lead including hire and running charges of vehicles, labour charges for loading and unloading as required for the work etc. complete as per the direction of the Engineer-in-charge.
58Electrical portion of Work
59Wiring
60Wiring to light points/ ceiling fan point/ exhaust fan point/Call bell point with 1.5-sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia 2mm thick non metalic PVC rigid conduit pipe with 6Amp, 250V Modular Switch ISI marked and ceiling rose ISI marked mounted on Metal box having front Modular cover of suitable size, metal box with 1.5sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection complete as per direction of Engineer-in-charge.
61Primery light point
62Secondary point
63Exhaust fan point specification same as above.
64Ceiling fan point.
65Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
66Supply and fixing of 6Amp plug with 6amp switch on existing board (Modular type ISI marked)
67Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
68Supply and fixing of modular metal box on surface or recess with suitable size of modular cover in front including providing an fixing of ISI marked 16Amp plug with 16A switch with all conection as required.
69Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required.
70Submains:
71Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed 2mm thick PVC rigid conduit pipe as required complete as per direction of engineer in charge.
722 x 1.5 sq.mm. + 1 x 1.5 sq.mm.
732 x 2.5 sq.mm. + 1 x 2.5 sq.mm.
742 x 4.0 sq.mm. + 1 x 4.0 sq.mm.
752 x 6.0 sq.mm. + 1 x 6.0 sq.mm.
764 x 4.0 sq.mm. + 2 x 4.0 sq.mm.
774 x 6.0 sq.mm. + 2 x 6.0 sq.mm.
784 x 10.0 sq.mm. + 2 x 6.0 sq.mm.
79TV/Telephone Wiring:
80Supply, delivery, installation, testing and commssioning of modular type TV Antenna/Telephone Outlet Boards containing a ISI markedModular TV Antenna/Telephone Socket fixed on Modular Concealed Box including connections and making good the damages caused complete as required and as per Dierction of Engineer-In-Charge.
81Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
82Supplying and drawing 2 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed conduit as required.
83Supplying and fixing of following sizes of 2mm thick rigid PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required complete as per Dierction of Engineer-In-Charge.
8420 mm dia
8525 mm dia
86Controll Panel & BDB
87Main Distribution Board
88Supply, delivery, installation, testing & commissioning of L.T. indoor floor/ wall mounted type main distributiob board made out of 2 mm thick CR sheet metal cubiclewith front side hinges glass door for every meter compartment, the cabinet have a common bus bar, duly acid treated for derusting, primered and painted with 2 coats of enamel paint of approved shade; dust, damp & vermin proof powder coated; having hinged door and compartmental arrangement for eachequipment& busbar chamber onthe top of the panel; having provision for cable/ conduit entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISSandasperspecial conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge.
89All MCCB shall confirm to IEC- 60947 and IS-13947. MCCB shall comply with the isolation function requirement of IEC-60947-2 section 7.1.2 to be marked as suitable for isolation / disconnection to facilitate safety of person in use. All MCCB have ics=100% icu and the overload setting should be from 0.7 to 1 times of Ir for thermal magenetic release and for microprocessor release the overload Settings: 0.4 to 1 times of Ir. Manually closing mechanism should be accommodated in a Moulded housing of robust and vermin-proof construction. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open) . The tripping devices shall be ambient temperature compensated type. The insulating case shall be made of high strength heat resistant and flame retardant thermosetting insulating material.
90Incoming :
91MCCB: 1 No 100A (16kA) 4P thermal magnetic(TM) with ROM & spreader links.
92SPD: 1No 50kA 4P T1+T2
93MCB "C": 1 No 63A 10kA 4P
94Outgoing :
95Busbar : 1 SET, 4 Nos 125 Amp Copper Strips. (CD=1.6A/sqmm)
96MCB "C" : 2 nos of 63A 10 kA 4P, 2 nos of 32A 10 kA 4P & 4 nos of 32A 10 kA 2P.
97Instruments:
981 Set of 0-500volt Digital voltmeterwith inbuilt selector switch, 1 set of LED type RYB phase indicating lamps with control fuses & 1no 0-100A digital ammeter with inbuilt selector switch with required CT"s
99Supply, delivery, installation, testing & commissioning of L.T. indoor floor/ wall mounted type Distribution Boards with metal door of reputed company make having provision for cable/ conduit entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISSandasperspecial conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge.
10012 way SPN metal double door Distribution Board
101incoming :
102RCCB : 1 no 40Amp 100mA DP
103outgoing
104MCB "C" : 10nos 6-16Amp 10kA SP
1054 way TPN metal double door Distribution Board for Light
106incoming :
107RCCB : 1 no 25A (100mA) 4P
108outgoing
109MCB "C" : 12nos of (16-32)Amp 10kA SP as per SLD
1104 way TPN metal double door Distribution Board for Power
111incoming :
112MCB "C" : 1 no 63A 10kA 4P
113outgoing
114MCB "C" : 12nos of (16-32)Amp 10kA SP as per SLD
115Cabling
116Supply of following size of XLPE insulated & PVC sheathed Armoured Aluminium power cables ISI marked complete as per the direction of Engineer-in-charge.
1173&1/2 core x 25 sqmm PVC armoured cable
118Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
119Upto 35 sq. mm
120Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required complete as per the direction of Engineer-in-charge.
121Upto 35 sq. mm
122Cable termination:
123Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required complete as per the direction of Engineer-in-charge.
1243½ X 25 sq. mm (28mm)
125Earthing
126Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required and as per the direction of Engineer in charge.
127Supplying and laying 25 mm x 5mm G.I. strip on surface or in recess for connection etc as required complete as per the direction of Engineer-in-charge.
128Providing and fixing 6 SWG G.I. wire on surface or in recess for loop earthing as required complete as per the direction of Engineer-in-charge.
129Fittings & Fixtures
130Supply, Installation, testing & commissioning of following types of light fixtures directly on wall / ceiling of building with allaccessories such as drivers, lamps cover etc complete assembly including supply of all accessories and making connection from the suitable point outlet complete as per the direction of Engineer-in-charge.
131All purpose surface and wall mounted 20 watt LED batten with aluminum housing & integrated electronic driver having THD<20% similar to make Havells Cat no. LUMILINEPLUSBS20WLED865SPCSS complete.
132Aesthetically designed 15 watt LED flat panel for surface mounting which provides soft-light and glare free symmetrical illumination similar to make HAVELLS Cat no.PLUTOSURFA CE1X1PLS15WLED857S complete.
13310 watt or above Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head Back-lit LED luminaire comprising of high brightness LEDs (IP66) similar to make HAVELLS Cat no. HEXAFT10WLED857SSYMBOPC complete.
13430w LED street light including GI pipe bracket, necessary wiring from loop-in-box with 1.5 sqmm copper wires inside PVC pipes etc complete as required with all materials as per direction of Engineer-in-charge similar to make HAVELLS Cat no. ENDURA CITYLITE PLAT PLUS SL30W LED757SASYBOPC complete.
135Supply, delivery, installation, testing & commissioning of BEE Star rated 1200mm sweep ceiling fan as per direction of Engineer-in-charge similar to make Crompton HS Plus - 1 Star BEE* complete.
136Supply, delivery, installation, testing & commissioning of metal Exhaust fan 300mm sweep as per direction of Engineer-in-charge similar to make Crompton Trans Air 12" complete.
137Supply and fixing circular/ HEXAGONAL G.I. box for ceiling fan hook, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick G.I. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the G.I.box by means of 3.3 mm dia round headed screws, one lock at the corners. Hook shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
138N.B - The bidders are required to Quote their rates excluding of Goods & Service Tax (GST). GST as applicable will be paid extra. The existing rule of Govt. and any amendment made in future will be followed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail