Tender For M/O Office Building Under North Zone., Delhi-Delhi

Delhi Development Authority-DDA has published Tender For M/O Office Building Under North Zone.. Submission Date for this Tender is 25-05-2023. Air Conditioner Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

37745623
Tender For M/O Office Building Under North Zone.
Open Tender
Indian
Delhi
Delhi
25-05-2023

Tender Details

Sh-M / O E.I. And Fans Desert Cooler, Water Cooler, Air Conditioners And Submersible Pump Set At Office Building Of Civil Circle-11, Nd-1, Nd-9 Near T.V. Tower, And Dy. Dir. Lm / N.Z.At Lu Block - Pitampura....As Per Tender Notice.

Key Value

Document Fees
Refer document
EMD
INR 36825.0 /-
Tender Value
INR 18.41 Lakhs /-

BOQ Items

Name of work : M/o Office building under North Zone. SH: M/o E.I. & Fans Desert Cooler, Water cooler, Air conditioners & submersible pump set at office buildingof Civil Circle-11,ND-1, ND-9 near T.V. Tower,and Dy. Dir. LM/N.Z. at LU Block-Pitampura. SH: M/o E.I. & Fans Desert Cooler, Water cooler, Air conditioners & submersible pump set at DDA office complex, ELD.7/ND-5atLawrence Road & CC-12, ND-10, ND-11 & CAUOffice complex at Ashok Vihar
Sl. No. Item Description
1Annual running maintenance of internal & external electrical installations of following officesas per inventory terms & conditions attached. i. N.D.-1 Pitampura ii. Northern Divn. 9 / Pitampura iii. Civil Circle-1/ Pitampura. iv. Dy. Dir. (L.M.) LU block, Pitampura
2Annual running maintenance of internal & external electrical installations of following officesas per inventory terms & conditions attached. i. Elect. Divn. 7/ Lawrence Road. ii. Northern Divn. 5 / Lawrence Road. iii. Northern Divn. 10 / Ashok Vihar. iv. Northern Divn. 11 / Ashok Vihar. v. Civil Circle-12 / Ashok vihar. vi. C.A.U. / North Zone / Ashok Vihar.
3Lifting of sub. Pump set with G.I. delivery pipe and its connecting cable from the bore well i/c dismantling of G.I. pipe and cable from the pump set etc. complete as reqd.
4Lowering of sub. Pump set along with G.I. pipe and its accessories in the bore well and replacement of G.I. nut, bolt and washers i/c making cable jointing, connection, testing etc. complete as reqd.
5Supplying & replacement (from deputed labour) of following size cable FRLS , ISI mareked. FRLS PVC insulated, copper conductor cable i/c connection, testing etc. as required.
61.5 Sqmm (Single Core)
74 Sqmm (Single Core)
8S.I.T.C. (from deputed labour)of ceiling fan 1400mm sweep suitable for working at 230 volt 50 Hz. AC supply + 10% pearl white metalic colour in good condition at site etc. as reqd.
9Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 12 way , Double door
10Supplying & replacement (from deputed labour)of following items ( ISI marked) suitable to operate on 240 volts A.C. supply, testing etc. as reqd.
115/6Amp. Piano type switch
1215/16Amp. Piano type switch
135/6Amp. Bell push piano type
143 pin 5/6Amp. socket outlet piano type
156 Pin 15/16Amp. Socket outlet piano type
16Call bell / buzzer
176 to 32 Amp. S.P. MCB (C) Curve – 10 KA
1832 AmpDPMCB (C) Curve 10 KA
19Supplying and fixing(from deputed labour)following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) 63 A
20Supplying and fixing(from deputed labour)125A MCCB , four pole, rating 36 KA,complete with connections, testing and commissioning etc. as required.
21Supplying and fixing following modular switch/ socket on theexisting modular plate &switch box including connections but excluding modular plate etc. as required .
225/6 amps switch
232 way 5/6 A switch
2415/16 A switch Each
253 pin 5/6 A socket outlet
266 pin 15/16 A socket outlet
27Rewinding of 1400 mm sweep ceiling fani/c dismantling, varnishing greasing, reassembling, re-installation,connections & testing etc completeas required.
28Rewinding of exhaust fan of size 18" sweepi/c removing , dismantling, varnishing, greasing, reassembling,reinstallation, connection & testing etc. complete as required.
29Supplying & replacement (from deputed labour)of following items of 18"/20" desert cooler.
30Round cable 3 X 1.5 sq.mm PVC insulated copper conductor cable - 3 mtr. Long
313 pin top 15 Amp.(ISI marked)
32capacitor 4 mfd
33Rewinding (Coppe winding) & repairing of 18/20" desert cooler fan motor of defferent make 900/1400 rmp testing etc. complete as required.
34Supplyig & fixing of cooler stand suitable for 18/20" desert cooleretc. complete as required.
35Supplying & replacement (from deputed labour) of front grill made out of 20 SWG GI sheet suitable for 18"/20" desert cooler i/c GI nut bolts screws washer etc after removing the existing grill testing etc as required.
36Supplying & replacement (from deputed labour) of 450mm sweep 1400 rpm (approx) cooler fan motor (copper wound)(3 speed) complete with motor blade & mounting accessories suitable for 18"/20" desert cooler, providing & fixing GI nut bolts of suitable size legs, connections, testing etc complete as required.
37Supplying & replacement (from deputed labour)body of 18"/20" desert cooler having size86 cm X 65 cm X 65 cm (H X B X D) (+3%) made out of 18 SWG GI (sheet tank) & 20 SWG GI grill top front & side louvers with distributor PVC pipe 1/2" dia wood wool pads control plate with 2 nos. 5 Amp. Switch etc as required.
38Supplying & replacement (from deputed labour) of electric power driven cooler pump (submersible type) 1400 rpm (approx) having one meter lead, discharge 5 ltrs /min. (approx) providing G.I.Strip, nut bolts of suitable size for 18" /20" cooleretc. as required .
39Paintingof desert cooler of size 18"/20" after removing ofrust & cleaning of dust with two coat of synthetic enamel paint of approved colour andnumberingwith Alpha numerical letter of 1" width on desert cooler etc. as required.
40Suppying & replacementof wood wool pad in 18"/20" in desert cooler i/c PVC pipe, pad holding wiremesh after cleaning of desert cooler, oiling of motor, etc. as required.
41Servicing of water cooler 40/80 ltr. Capacity oiling in fan motor, Cleaning of base plate and condenser coil with chemical and cleaning of water tank etc. complete as required.
42Supplying & Gas charging in water cooler i/c testing, commissioning etc. complete as required.
43Service of splittype air conditioner of 1.5/2.0 ton capacity i/ccleaning of cooling coil & condenser with chemical, washing the complete air-conditioner, painting of sheet metal parts hose plate with synthetic enamel i/c painting of exposed cooling & condenser pipes with anti corrosion paint, oiling of fan motor, etc as required
44Supply and replacement of20 watt PVC housing LED batten with integrated electric driveri/c connection, testing etc. complete as required and dismantling of old and damage fitting etc. as required
45Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. a) Group B
46Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
473 x 1.5 sq. mm
483 x 4 sq. mm
49Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
5020 mm
5125mm
52Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required.
536 Module (200mmX75mm)
548 Module (125mmX125mm)
5512 Module (200mmX150mm)
56Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
576 Module
5812 Module
59Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
60Supplying and installation of 34 watt, 2x2 LED light, environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminair with high brightness SMD LEDs as light source, suitable for Armstong/Grid ceilingi/c all accessories etc as required.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail