Tender For Matheran Electrical Material Supply, Raigad-Maharashtra

Directorate Of Municipal Administration-DMA has published Tender For Matheran Electrical Material Supply. Submission Date for this Tender is 25-05-2023. Electrical Maintenance Tenders in Raigad Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

37745599
Corrigendum : Tender For Matheran Electrical Material Supply
Open Tender
Indian
Maharashtra
Raigad
25-05-2023

Tender Details

Matheran Electrical Material Supply , Supplying & Erecting Crimping Type Copper Lugs For Cable 70 Sq Mm Complete As Per Specification No. Cb-Cl/Cu , Supplying, Installing, Testing And Commissioning Of Single Phase, 230V, 50 Hz, 800 To 900Va Digital Pure Sine Wave Inverter With Backup Time Of ........ Hrs. Based On Insulated Gate Bipolar Transistor (Igbt) Technology Complete As Per Specification No. Ap-Inv , Supplying, Installing, Testing And Commissioning Of Single Phase, 230V, 50 Hz, 700Va Digital Pure Sine Wave Inverter With Backup Time Of ........ Hrs. Based On Insulated Gate Bipolar Transistor (Igbt) Technology Complete As Per Specification No. Ap-Inv , Supplying, Installing, Testing And Commissioning Of Single Phase, 230V, 50 Hz, 2500 Va Digital Pure Sine Wave Inverter With Backup Time Of ........ Hrs. Based On Insulated Gate Bipolar Transistor (Igbt) Technology Complete As Per Specification No. Ap-Inv , Supplying, Installing, Testing And Commissioning Of Single Phase, 230V, 50 Hz, 1400 To 1600Va Digital Pure Sine Wave Inverter With Backup Time Of ........ Hrs. Based On Insulated Gate Bipolar Transistor (Igbt) Technology Complete As Per Specification No. Ap-Inv , Supplying, Installing, Testing And Commissioning 11Kv Hrc Fuse 10A To 40A For Load Break Switch With Necessary Nut Bolts Complete. , Supplying, Installing, Testing And Commissioning 11 Kv Hrc Fuse 63A For Load Break Switch With Necessary Nut Bolts Complete. , Supplying, Installing, Testing & Commissioning Window Type Variable Speed Inverter Technology With Minimum 3 To 1 Convertible Mode For Compressor, Room Air Conditioning Unit 1.3Tr To 1.6Tr Capacity Having Iseer Minimum 3.5 Suitable To Operate On 250V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall/Floor Mounting Type Complete With Refrigerant R32 Having Copper Condenser, Minimum 2.5Pm Filter, Self Diagnosis Feature, Stabilizer Free Operation & Temperature Display On Indoor Unit, Noise Level Maximum 50Dba At Position As Per Specification No. Apac/ Wac , Supplying, Installing, Testing & Commissioning Window Type Variable Speed Inverter Technology With Minimum 3 To 1 Convertible Mode For Compressor, Room Air Conditioning Unit 1.0Tr To 1.2Tr Capacity Having Iseer Minimum 3.5 Suitable To Operate On 250V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall/Floor Mounting Type Complete With Refrigerant R32 Having Copper Condenser, Minimum 2.5Pm Filter, Self Diagnosis Feature, Stabilizer Free Operation & Temperature Display On Indoor Unit, Noise Level Maximum 50Dba At Position In Provided Recess With Wooden Frame Complete Specification No. Ap-Ac/Wac , Supplying, Installing, Testing & Commissioning Window Type Variable Speed Inverter Technology With Minimum 3 To 1 Convertible Mode For Compressor, Room Air Conditioning Unit 1.0Tr To 1.2Tr Capacity Having Iseer Minimum 3.1 To Maximum 3.29 Suitable To Operate On 250V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall/Floor Mounting Type Complete With Refrigerant R32 Having Copper Condenser, Minimum 2.5Pm Filter, Self Diagnosis Feature, Stabilizer Free Operation & Temperature Display On Indoor Unit, Noise Level Maximum 50Dba At Position In Provided Recess With Wooden Frame Complete Specification No. Ap , Supplying, Installing, Testing & Commissioning Window Type Variable Speed Inverter Technology With Minimum 3 To 1 Convertible Mode For Compressor, Room Air Conditioning Unit 0.7Tr To 0.9Tr Capacity Having Iseer Minimum 3.1 To Maximum 3.29 Suitable To Operate On 250V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall/Floor Mounting Type Complete With Refrigerant R32 Having Copper Condenser, Minimum 2.5Pm Filter, Self Diagnosis Feature, Stabilizer Free Operation & Temperature Display On Indoor Unit, Noise Level Maximum 50Dba At Position In Provided Recess With Wooden Frame Complete Specification No. Ap , Supplying, Installing, Testing & Commissioning Split Type Variable Speed Inverter Technology With Minimum 3 To 1 Convertible Mode For Compressor, Room Air Conditioning Unit 1.7Tr To 2.0Tr Capacity Having Iseer Minimum 3.8 To Maximum 4.39 Suitable To Operate On 250V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall/Floor Mounting Type Complete With Refrigerant R32 Having Copper Condenser, Minimum 2.5Pm Filter, Self Diagnosis Feature, Stabilizer Free Operation & Temperature Display On Indoor Unit, Noise Level Maximum 50Dba At Position As Per Specification No. Apac/ Wac , Supplying, Installing, Testing & Commissioning Split Type Variable Speed Inverter Technology With Minimum 3 To 1 Convertible Mode For Compressor, Room Air Conditioning Unit 1.3Tr To 1.6Tr Capacity Having Iseer Minimum 5.00 Suitable To Operate On 250V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall/Floor Mounting Type Complete With Refrigerant R32 Having Copper Condenser, Minimum 2.5Pm Filter, Self Diagnosis Feature, Stabilizer Free Operation & Temperature Display On Indoor Unit, Noise Level Maximum 50Dba At Position As Per Specification No. Apac/ Wac , Supplying, Installing, Testing & Commissioning Split Type Variable Speed Inverter Technology With Minimum 3 To 1 Convertible Mode For Compressor, Room Air Conditioning Unit 1.3Tr To 1.6Tr Capacity Having Iseer Minimum 3.8 To Maximum 4.39 Suitable To Operate On 250V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall/Floor Mounting Type Complete With Refrigerant R32 Having Copper Condenser, Minimum 2.5Pm Filter, Self Diagnosis Feature, Stabilizer Free Operation & Temperature Display On Indoor Unit, Noise Level Maximum 50Dba At Position As Per Specification No. Apac/ Wac , Supplying, Installing, Testing & Commissioning Split Type Variable Speed Inverter Technology With Minimum 3 To 1 Convertible Mode For Compressor, Room Air Conditioning Unit 1.0Tr To 1.2Tr Capacity Having Iseer Minimum 5.00 Suitable To Operate On 250V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall/Floor Mounting Type Complete With Refrigerant R32 Having Copper Condenser, Minimum 2.5Pm Filter, Self Diagnosis Feature, Stabilizer Free Operation & Temperature Display On Indoor Unit, Noise Level Maximum 50Dba At Position As Per Specification No. Apac/ Wac , Supplying, Installing, Testing & Commissioning Split Type Variable Speed Inverter Technology With Minimum 3 To 1 Convertible Mode For Compressor, Room Air Conditioning Unit 1.0Tr To 1.2Tr Capacity Having Iseer Minimum 3.8 To Maximum 4.39 Suitable To Operate On 250V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall/Floor Mounting Type Complete With Refrigerant R32 Having Copper Condenser, Minimum 2.5Pm Filter, Self Diagnosis Feature, Stabilizer Free Operation & Temperature Display On Indoor Unit, Noise Level Maximum 50Dba At Position As Per Specification No. Apac/ Wac , Supplying, Installing, Testing & Commissioning Ip Epabx For 10 Extensions Complete. , Supplying, Installing, Testing & Commissioning Digital (Hybrid) Type Epabx Of 6 X 16 Extension Complete. , Supplying, Installing, Testing & Commissioning Digital (Hybrid) Type Epabx Of 3 X 8 Extensions Complete. , Supplying, Installing, Testing & Commissioning Analogue Type Epabx Of 3 X 8 Extension Complete. , Supplying, Installation, Testing And Commissioning Of Main Fire Pump (Mfp / Ep) Suitable For Water Discharge Of 2280 To 2850Lpm At 80 To 60 M Head Driven By Electric Motor 415 Volts, 3 Phase 50 Hz, Ac Supply Of 45Kw Or Of Suitable Kw Capacity For Manual/Automatic Operation And Consisting Of Following : (A) Horizontal Type, Single Stage, Centrifugal/Split Casing Pump Of Cast Iron Body & Bronze Impeller With Stainless Steel Shaft(Ss410 Grade), Mechanical Seal Conforming To Is 1520. (B) Squirrel Cage Induction Motor, Tefc, Synchronous Speed 3000 Rpm, Suitable For Operation With Ip 55 Protection For Enclosure, Horizontal Foot Mounted Type With Class-F Insulation, Conforming To Is-325. (C) M.S. Fabricated Common Base Plate, Coupling, Coupling Guard, Foundation Bolts Etc. As Required. (D) Erected On Provided Suitable Size Cement Concrete Foundation Duly Plastered With Anti Vibration Pads With Perfect Aligning, Proper Levelling Complete Pump Set With Accessories Duly Painted With Two Coats Of Synthetic Enamel Paint Of Fire Red Colour Over A Coat Of Primer (Isc Code 536 As Per Is 2932 Of 2003) Complete, As Per Specification No. Ff-Mfp/Ssc/Ep , Supplying, Installation, Testing And Commissioning Of Main Fire Pump (Mfp / Ep) Suitable For Water Discharge Of 1600 To 1800 Lpm At 70 To 55 M Head Driven By Electric Motor 415 Volts, 3 Phase 50 Hz, Ac Supply Of 30Kw Or Of Suitable Kw Capacity For Manual/Automatic Operation And Consisting Of Following : (A) Horizontal Type, Single Stage, Centrifugal/Split Casing Pump Of Cast Iron Body & Bronze Impeller With Stainless Steel Shaft (Ss410 Grade), Mechanical Seal Conforming To Is 1520. (B) Squirrel Cage Induction Motor, Tefc, Synchronous Speed 3000 Rpm, Suitable For Operation With Ip 55 Protection For Enclosure, Horizontal Foot Mounted Type With Class-F Insulation, Conforming To Is-325. (C) M.S. Fabricated Common Base Plate, Coupling, Coupling Guard, Foundation Bolts Etc. As Required. (D) Erected On Provided Suitable Size Cement Concrete Foundation Duly Plastered With Anti Vibration Pads With Perfect Aligning, Proper Levelling Complete Pump Set With Accessories Duly Painted With Two Coats Of Synthetic Enamel Paint Of Fire Red Colour Over A Coat Of Primer (Isc Code 536 As Per Is 2932 Of 2003) Complete, As Per Specification No. Ff-Mfp/Ssc/Ep , Supplying, Installation, Testing And Commissioning 3 Phase, 22/0.433 Kv, 50 Hz., 315 Kva, Indoor Type, Vacuum Cast Coil (Vcc) Dry Type Cast Resin Transformer, Copper Wound , Dyn11 Vector Group, Delta/Star Connection With Additional Neutral Brought Out On Load Side, For Indoor Use Continuous Duty, Average Temp Rise Of Winding (At Principal Tap) 115°C At Ambient Temp Max 50°C & Min -5°C At Full Load Rating, With Tapping (With Off Circuit Bolted Links Type Tap Changer) For Off Load +5 To - 5% @ 2.5% In +2/-2 Steps, Hv Variation, Class Of Insulation H/H, Method Of Cooling An, No Load Loss At Rated Voltage & Frequency (+15% Is Tol) 1.80 Kw, Full Load Loss At Rated Current 3.00 Kw, With 98.50 % Efficiency At Full Load & 98.41 % At 1/2 Full Load, With 125 Kv Peak Full Wave Lightning Impulse Withstand Voltage With Complete Enclosure Having Ip 23 Degree Of Protection, Cable Box Arrangement At Hv Side & Bus Duct At Lv Side ,With Rating & Diagram Plate, Base Channel, Lifting Lugs, Earthing Terminals & Wti Scanner With 3 Pt-100 Sensors, Etc. Standard Accessories Complete With Test Certificate (As Per Is:11171 & Iec 60076-11) With Necessary Permissions Of Electrical Inspector, As Per Specification No. Ss- Tr. , Supplying, Installation, Testing And Commissioning 3 Phase, 11/0.433 Kv, 50 Hz., 315 Kva, Indoor Type, Vacuum Cast Coil (Vcc) Dry Type Cast Resin Transformer, Copper Wound , Dyn11 Vector Group, Delta/Star Connection With Additional Neutral Brought Out On Load Side, For Indoor Use Continuous Duty, Average Temperature Rise Of Winding (At Principal Tap) 115Oc At Ambient Temp Max 50Oc And Min -50Oc At Full Load Rating, With Tapping (Off Circuit Tap Links Type Tap Changer), For Off Load +5 To - 5% @ 2.5% In +2/-2 Steps, Hv Variation, Class Of Insulation H/H, Method Of Cooling An, No Load Loss At Rated Voltage And Frequency (+15% Is Toi) 1 Kw, Full Load Loss At Rated Current 3.15 Kw, With 98.70% Efficiency At Full Load & 98.88 % At 1/2 Full Load, With 75 Kv Peak Full Wave Lightning Impulse Withstand Voltage With Complete Enclosure Having Ip 21 Degree Of Protection, Cable Box Arrangement At Hv Side And Bus Duct At Lv Side, With Rating And Diagram Plate, Base Channel, Earthing Terminals And Wti Scanner With 3 Pt-100 Sensors, Etc., Standard Accessories Complete With Test Certificates (As Per Is:11171 & Is 2026) With Necessary Permissions Of Electrical Inspector As Per Specification No. Ss- Tr. , Supplying, Installation And Testing Of Maintenance Free Earthing Comprising Of Electrode Of 17.2 Mm Diameter Low Carbon Steel With 250 Micron Molecular Copper Bonded Earthing Rod Of Length 3M Along With 25 Kg Carbon Based Environment Friendly Back Fill Ground Enhancing Compound Required To Fill Up The Excavated Earth With Required Quantity Complete, And Recording The Results Specification No. Ea-Mobi , Supplying, Fixing, And Configuring Modularised Multi-Service Router 802.11/A/N/Ac Unified Wave 2.5 Ghz, With Rj-45 Port, Supporting 1 To 13 Channels For 2.4 Ghz, With Unified Wireless Access Point Complete , Supplying, Fixing, And Configuring 24 Ports With 4 (Sfp+) Port, Ethernet Managed Switch With Web View/Cli, 6Kv Surge Protection On Ethernet Port And Console Port For Management In Provided Rack As Per Specification No. WgNwc/Gbs , Supplying, Fixing, And Configuring 24 Ports + 4 (Sfp+) Port, Managed Layer 2, Poe Switch Of , 370W, 6Kv Surge Protection On Ethernet Port And Console Port For Management Erected In Provided Rack Complete. , Supplying, Fixing, And Configuring 20 Sfp Ports + 4 Combo Sfp 10/100/1000 Base-T Erected In Provided Rack Complete. , Supplying, Fixing, And Configuring 20 (1G-Rj45) Ports + 4 Combo 1G Ports + 4 10G (Sfp+) Ports, Layer 3 Switch, Si Image, 6Kv Surge Protection On Ethernet Port And Console Port For Management Erected In Provided Rack Complete. , Supplying, Fixing And Commissioning Mcb Type Change Over Switch 4 Pole, 63A With 3 Positions (I-O-Ii) With Centre Off Position As Per Specification No. Sw-Swr / Mcbcos , Supplying, Erecting, Testing And Commissioning Of Single Phase Input & 1 Phase Output 1 Kva Capacity Online Pure Sine Wave Ups, With Backup Time Of ....... Hrs. Pwm & Igbt Based, With 0.8 To Unity Output Pf Complete With All Protections As Per Specification No. Ap-Ups , Supplying, Erecting, Testing And Commissioning Of Microprocessor Based Amf Panel Suitable For Diesel Generating Set Of Above 82.5 Kva Up To 100 Kva Capacity Three Phase, 415 Volts, 50Hz A.C. With All Standard Features, Safeties Etc As Per Specification No. Gen-Amf. , Supplying, Erecting, Testing And Commissioning Of Microprocessor Based Amf Panel Suitable For Diesel Generating Set Of Above 62.5 Kva Up To 82.5 Kva Capacity Three Phase, 415 Volts, 50Hz A.C. With All Standard Features, Safeties Etc As Per Specification No. Gen-Amf. , Supplying, Erecting, Testing And Commissioning Of Microprocessor Based Amf Panel Suitable For Diesel Generating Set Of Above 50 Kva Up To 62.5 Kva Capacity Three Phase, 415 Volts, 50Hz A.C. With All Standard Features, Safeties Etc As Per Specification No. Gen-Amf. , Supplying, Erecting, Testing And Commissioning Of Microprocessor Based Amf Panel Suitable For Diesel Generating Set Of Above 40 Kva Up To 50 Kva Capacity Three Phase, 415 Volts, 50Hz A.C. With All Standard Features, Safeties Etc As Per Specification No. Gen-Amf. , Supplying, Erecting, Testing And Commissioning Of Microprocessor Based Amf Panel Suitable For Diesel Generating Set Of Above 35 Kva Up To 40 Kva Capacity Three Phase, 415 Volts, 50Hz A.C. With All Standard Features, Safeties Etc As Per Specification No. Gen-Amf. , Supplying, Erecting, Testing And Commissioning Of Microprocessor Based Amf Panel Suitable For Diesel Generating Set Of Above 25 Kva Up To 35 Kva Capacity Three Phase, 415 Volts, 50Hz A.C. With All Standard Features, Safeties Etc As Per Specification No. Gen-Amf. , Supplying, Erecting, Testing And Commissioning Of Microprocessor Based Amf Panel Suitable For Diesel Generating Set Of Above 20 Kva Up To 25 Kva Capacity Three Phase, 415 Volts, 50Hz A.C. With All Standard Features, Safeties Etc As Per Specification No. Gen-Amf. , Supplying, Erecting, Testing And Commissioning Of Microprocessor Based Amf Panel Suitable For Diesel Generating Set Of Above 15 Kva Up To 20 Kva Capacity Three Phase, 415 Volts, 50Hz A.C. With All Standard Features, Safeties Etc As Per Specification No. Gen-Amf. , Supplying, Erecting, Testing And Commissioning Of Microprocessor Based Amf Panel Suitable For Diesel Generating Set Of Above 125 Kva Up To 140 Kva Capacity Three Phase, 415 Volts, 50Hz A.C. With All Standard Features, Safeties Etc As Per Specification No. Gen-Amf. , Supplying, Erecting, Testing And Commissioning Of Microprocessor Based Amf Panel Suitable For Diesel Generating Set Of Above 100 Kva Up To 125 Kva Capacity Three Phase, 415 Volts, 50Hz A.C. With All Standard Features, Safeties Etc As Per Specification No. Gen-Amf. , Supplying, Erecting, Testing And Commissioning Of Microprocessor Based Amf Panel Suitable For Diesel Generating Set Of Above 10 Kva Up To 15 Kva Capacity Three Phase, 415 Volts, 50Hz A.C. With All Standard Features, Safeties Etc As Per Specification No. Gen-Amf. , Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Standard Control Panel With Alternator Of 5 Kva Continuous Rating, Single Phase, 230V, 50C/S 0.8 P. F. Ac Supply A Totally Enclosed Air / Liquid Cooled Multi Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours With Standard Accessories, Self-Excited, SelfRegulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation +/- 5 %, With Performance Class G2 And Maximum Fuel Consumption Of 1.3 Ltr/Hr @75% Loading. Engine And Alternator Directly Coupled On A Common Fabricated Steel Base Plate With Anti-Vibrating Pad, With Control Panel Comprising Of Standard Meters, Switchgears, Indicators Connected With Suitable Wires/Cables. The Complete Set Enclosed In Acoustic Enclosure Made Of 18 Swg Crca Sheet, Sound Absorbing Material, Rockwool Covered From Inside With ¾ Mm Holes Perforated Sheet To Restrict Sound Level Up To 75 Db At 1.0 M. The Engine With First Filling Of Oil, Diesel Not Less Than 13 Ltr Etc. On Provided M20 Grade Cc Foundation As Per Specification No. Gen-Dg , Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 82.5 Kva Output Continuous Rating, 3 Phase, 415 V, 50C/S 0.8 P. F. A.C Supply, A Totally Enclosed Air Cooled / Liquid Cooled Multi-Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours, Along With Standard Accessories, Self-Excited, Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation +/- 5 %, With Performance Class G2 And Maximum Fuel Consumption 14.0 Ltr/Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mounted On Anti-Vibrating Pads With Standard Control Panel Comprising Meters, Switchgears, Indicators Connected With Suitable Wires/Cables, The Complete Set Enclosed In Composite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swg Crca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db At 1.0 M, Provided With First Filling Of Oil, Diesel Not Less Than 145 Ltr Etc. On Provided M20 Grade Cc Foundation As Per Specification No. Gen-Dg , Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 62.5 Kva Output Continuous Rating, 3 Phase, 415 V, 50C/S 0.8 P. F. A.C Supply, A Totally Enclosed Air Cooled / Liquid Cooled Multi-Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours, Along With Standard Accessories, Self-Excited, Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation +/- 5 %, With Performance Class G2 And Maximum Fuel Consumption 11.3 Ltr/Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mounted On Anti-Vibrating Pads With Standard Control Panel Comprising Meters, Switchgears, Indicators Connected With Suitable Wires/Cables, The Complete Set Enclosed In Composite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swg Crca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db At 1.0 M, Provided With First Filling Of Oil, Diesel Not Less Than 150 Ltr Etc. On Provided M20 Grade Cc Foundation As Per Specification No. Gen-Dg , Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 50 Kva Output Continuous Rating, 3 Phase, 415 V, 50C/S 0.8 P. F. A.C Supply, A Totally Enclosed Air Cooled / Liquid Cooled Multi-Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours, Along With Standard Accessories, Self-Excited, Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation +/- 5 %, With Performance Class G2 And Maximum Fuel Consumption 9.98 Ltr/Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mounted On Anti-Vibrating Pads With Standard Control Panel Comprising Meters, Switchgears, Indicators Connected With Suitable Wires/Cables, The Complete Set Enclosed In Composite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swg Crca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db At 1.0 M, Provided With First Filling Of Oil, Diesel Not Less Than 150 Ltr Etc. On Provided M20 Grade Cc Foundation As Per Specification No. Gen-Dg , Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 40 Kva Output Continuous Rating, 3 Phase, 415 V, 50C/S 0.8 P. F. A.C Supply, A Totally Enclosed Air Cooled / Liquid Cooled Multi-Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours, Along With Standard Accessories, Self-Excited Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation +/- 5 %, With Performance Class G2 And Maximum Fuel Consumption 7.47 Ltr/Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mounted On Anti-Vibrating Pads With Standard Control Panel Comprising Meters, Switchgears, Indicators Connected With Suitable Wires/Cables, The Complete Set Enclosed In Composite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swg Crca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db At 1.0 M, Provided With First Filling Of Oil, Diesel Not Less Than 75 Ltr Etc. On Provided M20 Grade Cc Foundation As Per Specification No. Gen-Dg , Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 30 Kva Output Continuous Rating, 3 Phase, 415 V, 50C/S 0.8 P. F. A.C Supply, A Totally Enclosed Air Cooled / Liquid Cooled Multi-Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours, Along With Standard Accessories, Self-Excited, Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation +/- 5 %, With Performance Class G2 And Maximum Fuel Consumption 5.9 Ltr/Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mounted On Anti-Vibrating Pads With Standard Control Panel Comprising Meters, Switchgears, Indicators Connected With Suitable Wires/Cables, The Complete Set Enclosed In Composite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swg Crca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db At 1.0 M, Provided With First Filling Of Oil, Diesel Not Less Than 65 Ltr Etc. On Provided M20 Grade Cc Foundation As Per Specification No. Gen-Dg , Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 25 Kva Output Continuous Rating, 3 Phase, 415 V, 50C/S 0.8 P. F. A.C Supply, A Totally Enclosed Air Cooled / Liquid Cooled Multi-Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours, Along With Standard Accessories, Self-Excited, Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation +/- 5 %, With Performance Class G2 And Maximum Fuel Consumption 5.0 Ltr/Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mounted On Anti-Vibrating Pads With Standard Control Panel Comprising Meters, Switchgears, Indicators Connected With Suitable Wires/Cables, The Complete Set Enclosed In Composite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swg Crca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db At 1.0 M, Provided With First Filling Of Oil, Diesel Not Less Than 65 Ltr Etc. On Provided M20 Grade Cc Foundation As Per Specification No. Gen-Dg , Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 200 Kva Output Continuous Rating, 3 Phase, 415 V, 50C/S 0.8 P. F. A.C Supply, A Totally Enclosed Air Cooled / Liquid Cooled Multi-Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours, Along With Standard Accessories, Self-Excited, Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation +/- 5 %, With Performance Class G2 And Maximum Fuel Consumption 34.40 Ltr/Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mounted On Anti-Vibrating Pads With Standard Control Panel Comprising Meters, Switchgears, Indicators Connected With Suitable Wires/Cables, The Complete Set Enclosed In Composite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swg Crca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db(A) At 1.0 M, Provided With First Filling Of Oil, Diesel Not Less Than 300 Ltr Etc. On Provided M20 Grade Cc Foundation As Per Specification No. Gen-Dg , Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 20 Kva Output Continuous Rating, 3 Phase, 415 V, 50C/S 0.8 P. F. A.C Supply, A Totally Enclosed Air Cooled / Liquid Cooled Multi-Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours, Along With Standard Accessories, Self-Excited, Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation +/- 5 %, With Performance Class G2 And Maximum Fuel Consumption Of 3.8 Ltr/Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mounted On Anti-Vibrating Pads With Standard Control Panel Comprising Meters, Switchgears, Indicators Connected With Suitable Wires/Cables, The Complete Set Enclosed In Composite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swg Crca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db At 1.0 M, Provided With First Filling Of Oil, Diesel Not Less Than 50 Ltr Etc. On Provided M20 Grade Cc Foundation As Per Specification No. Gen-Dg , Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 15 Kva Output Continuous Rating, 3 Phase, 415 V, 50C/S 0.8 P. F. A.C A Totally Enclosed Air Cooled / Liquid Cooled Multi-Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours, Along With Standard Accessories, Self-Excited, Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation +/- 5 %, With Performance Class G2 And Maximum Fuel Consumption Of 3.0 Ltr/Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mounted On AntiVibrating Pads With Standard Control Panel Comprising Meters, Switchgears, Indicators Connected With Suitable Wires/Cables, The Complete Set Enclosed In Composite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swg Crca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db At 1.0 M, Provided With First Filling Of Oil, Diesel Not Less Than 40 Ltr Etc. On Provided M20 Grade Cc Foundation As Per Specification No. Gen-Dg , Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 100 Kva Output Continuous Rating, 3 Phase, 415 V, 50C/S 0.8 P. F. A.C Supply, A Totally Enclosed Air Cooled / Liquid Cooled Multi-Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours, Along With Standard Accessories, Self-Excited, Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation +/- 5 %, With Performance Class G2 And Maximum Fuel Consumption 17.4 Ltr/Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mounted On Anti-Vibrating Pads With Standard Control Panel Comprising Meters, Switchgears, Indicators Connected With Suitable Wires/Cables, The Complete Set Enclosed In Composite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swg Crca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db At 1.0 M, Provided With First Filling Of Oil, Diesel Not Less Than 230 Ltr Etc. On Provided M20 Grade Cc Foundation As Per Specification No. Gen-Dg , Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 10 Kva Output Continuous Rating, 3 Phase, 415 V, 50C/S 0.8 P. F. A.C Supply A Totally Enclosed Air Cooled / Liquid Cooled Multi-Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours, Along With Standard Accessories, Self-Excited, Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation +/- 5 %, With Performance Class G2 And Maximum Fuel Consumption Of 2.4 Ltr/Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mounted On Anti-Vibrating Pads With Standard Control Panel Comprising Of Meters, Switchgears, Indicators Connected With Suitable Wires/Cables, The Complete Set Enclosed In Composite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swg Crca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db At 1.0 M, Provided With First Filling Of Oil, Diesel Not Less Than 40 Ltr Etc. On Provided M20 Grade Cc Foundation As Per Specification No. Gen-Dg , Supplying, Erecting, Testing And Commissioning Of 6Kva Capacity Online Pure Sine Wave With Backup Time Of ....... Hrs. Pwm & Igbt Based Ups With 0.9 To Unity Output Pf, Single Phase Input & 1 Phase Output Complete With All Protections As Per Specification No. Ap-Ups , Supplying, Erecting, Testing And Commissioning Of 3Kva Capacity Online Pure Sine Wave With Backup Time Of ....... Hrs. Pwm & Igbt Based Ups With 0.8 To Unity Output Pf, Single Phase Input & 1 Phase Output Complete With All Protections As Per Specification No. Ap-Ups , Supplying, Erecting, Testing And Commissioning Of 2Kva Capacity Online Pure Sine Wave, With Backup Time Of ....... Hrs. Pwm & Igbt Based Ups With 0.8 To Unity Output Pf, Single Phase Input & 1 Phase Output Complete With All Protections As Per Specification No. Ap-Ups , Supplying, Erecting, Testing And Commissioning Of 28Hp, Vrf/Vrv Air Conditioning System Outdoor Unit (Odu) Complies Type-Iv Oem Standards Working On Hfc Refrigerant R410a Or Other Required/Suitable Green Equivalent Refrigerant, For Minimum Cooling Capacity As Delivering 100% Capacity At 47° C, Non Stop Cooling Even At 56° C And Coefficient Of Performance (Cop) 3.00 To 4.00, Modular Type Vertical Hot Air Discharge Suitable For Longer Piping Range Upto 1000 Metre Operation In Cooling Mode With Inverter/Digital Vrf/Vrv Technology Microprocessor Based Control Compressor Starter/Control Panel With Scroll Compressor, Air Cooled Copper Condenser Coil Of Suitable Shape For Increasing Maximum Heat Transfer Area, Rain Protection Cover, Built In Oil Separator, Accumulator And Oil Receiver, Copper Tube Aluminium Fin Air Cooled Condenser, Condenser Fan With Motor Suitable For 415V±10%, 50 Hz, 3 Phase Power Supply (All Suitable For High Ambient Conditions), Internal Copper Refrigerant Piping, Internal Wiring And Refrigerant, Etc. All Housed In Powder Coated Weather Proof Cabinet Complete. , Supplying, Erecting, Testing And Commissioning Of 20Hp, Vrf/Vrv Air Conditioning System Outdoor Unit (Odu) Complies Type-Iv Oem Standards Working On Hfc Refrigerant R410a Or Other Required/Suitable Green Equivalent Refrigerant, For Minimum Cooling Capacity As Delivering 100% Capacity At 47° C, Non Stop Cooling Even At 56°C And Coefficient Of Performance (Cop) 3.00 To 4.00, Modular Type Vertical Hot Air Discharge Suitable For Longer Piping Range Upto 1000 Metre Operation In Cooling Mode With Inverter/Digital Vrf/Vrv Technology Microprocessor Based Control Compressor Starter/Control Panel With Scroll Compressor, Air Cooled Copper Condenser Coil Of Suitable Shape For Increasing Maximum Heat Transfer Area, Rain Protection Cover, Built In Oil Separator, Accumulator And Oil Receiver, Copper Tube Aluminium Fin Air Cooled Condenser, Condenser Fan With Motor Suitable For 415V±10%, 50 Hz, 3 Phase Power Supply (All Suitable For High Ambient Conditions), Internal Copper Refrigerant Piping, Internal Wiring And Refrigerant, Etc. All Housed In Powder Coated Weather Proof Cabinet Complete. , Supplying, Erecting, Testing And Commissioning Of 12Hp, Vrf/Vrv Air Conditioning System Outdoor Unit (Odu) Complies Type-Iv Oem Standards Working On Hfc Refrigerant R410a Or Other Required/Suitable Green Equivalent Refrigerant, For Minimum Cooling Capacity As Delivering 100% Capacity At 47° C, Non Stop Cooling Even At 56° C And Coefficient Of Performance (Cop) 3.00 To 4.00, Modular Type Vertical Hot Air Discharge Suitable For Longer Piping Range Upto 1000M Operation In Cooling Mode With Inverter/Digital Vrf/Vrv Technology Microprocessor Based Control Compressor Starter/Control Panel With Scroll Compressor, Air Cooled Copper Condenser Coil Of Suitable Shape For Increasing Maximum Heat Transfer Area, Rain Protection Cover, Built In Oil Separator, Accumulator And Oil Receiver, Copper Tube Aluminium Fin Air Cooled Condenser, Condenser Fan With Motor Suitable For 415V±10%, 50 Hz, 3 Phase Power Supply (All Suitable For High Ambient Conditions), Internal Copper Refrigerant Piping, Internal Wiring And Refrigerant, Etc. All Housed In Powder Coated Weather Proof Cabinet Complete. , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 95 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 70 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/ Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Cu , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 70 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 6 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/ Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Cu , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 6 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 50 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/ Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Cu , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 4 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/ Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Cu , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 4 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 25 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 16 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 120 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 10 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/ Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Cu , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 10 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 3½ Core 95 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 3½ Core 50 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 3 Core 6 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/ Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Cu , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 3 Core 6 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 3 Core 4 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/ Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Cu , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 3 Core 4 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 3 Core 2.5 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/ Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Cu , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 3 Core 2.5 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 3 Core 10 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/ Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Cu , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 3 Core 10 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 3 Core 10 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 2 Core 6 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Cu , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 2 Core 6 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 2 Core 4 Sq Mm Copper Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Cu , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 2 Core 2.5 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/ Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Cu , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 2 Core 10 Sq. Mm. Copper Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/ Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Cu , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 2 Core 10 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V 2 Core 4 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al , Supplying, Erecting & Marking Spmcb 6A To 32A, C-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr/Mcb , Supplying, Erecting & Marking Spmcb 6A To 32A, B-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr/Mcb , Supplying, Erecting & Marking Spmcb 40A To 63A, C-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr/Mcb , Supplying, Erecting & Marking Spmcb 40A To 63A, B-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr/Mcb , Supplying, Erecting & Marking Fpmcb 6A To 32A, With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr/Mcb , Supplying, Erecting & Marking Fpmcb 40A To 63A, With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr/Mcb , Supplying, Erecting & Marking Dpmcb 6A To 32A, C-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr/Mcb , Supplying, Erecting & Marking Dpmcb 6 A To 32 A, B-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr/Mcb , Supplying, Erecting & Marking Dpmcb 40A To 63A, C-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr/Mcb , Supplying, Erecting & Commissioning Mdf Box 600X600 Pairs Made From Min. 1.5Mm Thick Ms Sheet As Per Specification No. Wg-Tw , Supplying, Erecting & Commissioning Mdf Box 50X50 Pairs Made From Min. 1.5Mm Thick Ms Sheet As Per Specification No. Wg-Tw , Supplying, Erecting & Commissioning Mdf Box 500X500 Pairs Made From Min. 1.5Mm Thick Ms Sheet As Per Specification No. Wg-Tw , Supplying, Erecting & Commissioning Mdf Box 400X400 Pairs Made From Min. 1.5Mm Thick Ms Sheet As Per Specification No. Wg-Tw , Supplying, Erecting & Commissioning Mdf Box 300X300 Pairs Made From Min. 1.5Mm Thick Ms Sheet As Per Specification No. Wg-Tw , Supplying, Erecting & Commissioning Mdf Box 250X250 Pairs Made From Min. 1.5Mm Thick Ms Sheet As Per Specification No. Wg-Tw , Supplying, Erecting & Commissioning Mdf Box 200X200 Pairs Made From Min. 1.5Mm Thick Ms Sheet As Per Specification No. Wg-Tw , Supplying, Erecting & Commissioning Mdf Box 150X150 Pairs Made From Min. 1.5Mm Thick Ms Sheet As Per Specification No. Wg-Tw , Supplying, Erecting & Commissioning Mdf Box 100X100 Pairs Made From Min. 1.5Mm Thick Ms Sheet As Per Specification No. Wg-Tw , Supplying, Erecting & Commissioning 4 Pole Rccb 80A, Electromagnetic Type With 30/100/300 Ma Sensitivity With Earth Leakage Trip Indication Complete As Per Specification No. Sw-Rccb/Rccb , Supplying, Erecting & Commissioning 4 Pole Rccb 63A, Electromagnetic Type With 30/100/300 Ma Sensitivity With Earth Leakage Trip Indication Complete As Per Specification No. Sw-Rccb/Rccb , Supplying, Erecting & Commissioning 4 Pole Rccb 40A, Electromagnetic Type With 30/100/300 Ma Sensitivity With Earth Leakage Trip Indication Complete As Per Specification No. Sw-Rccb/Rccb , Supplying, Erecting & Commissioning 4 Pole Rccb 16/25A, Electromagnetic Type With 30/100/300 Ma Sensitivity With Earth Leakage Trip Indication Complete As Per Specification No. Sw-Rccb/Rccb , Supplying, Erecting & Commissioning 4 Pole Rccb 100A, Electromagnetic Type With 30/100/300 Ma Sensitivity With Earth Leakage Trip Indication Complete As Per Specification No. Sw-Rccb/Rccb , Supplying, Erecting & Commissioning 2 Pole Rccb 63A, Electromagnetic Type With 30/100/300 Ma Sensitivity With Earth Leakage Trip Indication Complete As Per Specification No. Sw-Rccb/Rccb , Supplying, Erecting & Commissioning 2 Pole Rccb 40A, Electromagnetic Type With 30/100/300 Ma Sensitivity With Earth Leakage Trip Indication Complete As Per Specification No. Sw-Rccb/Rccb , Supplying, Erecting & Commissioning 2 Pole Rccb 16/25A, Electromagnetic Type With 30/100/300 Ma Sensitivity With Earth Leakage Trip Indication Complete As Per Specification No. Sw-Rccb/Rccb , Supplying Table Fan Of A.C. 230 V. 50 Cycles 400 Mm. Oscillating Type With Speed Regulator Complete With 2 Meter Of 3 Core Flexible Wire And Hand Shield Type 3 Pin Plug Top. , Supplying Pedestal Type Air Circulator 600 Mm. Sweep Oscillating Type Suitable To Work On 230 Volts 50 Cycles 1440 Rpm Without Speed Regulator, Metallic Blades, Overhead Protection Unit, Totally Enclosed, Flame Proof Motor With Additional 3 Core Wire, 5 Meter Length And Hand Shield Type 3 Pin6a. Plug Top Complete With Moisture Proof Treatment And ‘E’ Class Insulation. , Supplying Pedestal Type Air Circulator 450 Mm. Sweep Oscillating Type Suitable To Work On 230 Volts 50 Cycles 1440 Rpm With Speed Regulator, Metallic Blades, Overhead Protection Unit, Totally Enclosed, Flame Proof Motor With Additional 3 Core Wire, 5 Meter Length And Hand Shield Type 3 Pin 5A. Plug Top Complete With Moisture Proof Treatment And ‘E’ Class Insulation. , Supplying Led Concealed Type Foot / Step Light With Aluminium Body For Indoor/Outdoor Application Suitable For 4W-6W Led Including Driver And Erecting By Making Necessary Arrangement / Recess In Wall To Make It Flush With Surface With 1 Year Warranty. , Supplying Double Door Refrigerator Domestic Type Of 300 To 360 Litres Storage Capacity, Minimum 5 Star Inverter Type, Stabilizer Free Operation Suitable For Operation On 100V/300 V, 50Hz With Automatic Temperature Control, Shall Be Marked On Unit For Sealed Unit In Refrigeration System And Marking Sr. No. And Date Of Erection Complete. , Supplying And Plugging 3 M Fibre Patch Cord Lc-Sc Mm (50) Om4 Lszh Duplex Complete As Per Specification No. Wg-Coc/Fpc , Supplying And Plugging 3 M Fibre Patch Cord Lc-Sc Mm (50) Om3 Lszh Duplex Complete As Per Specification No. Wg-Coc/Fpc , Supplying And Plugging 3 M Fibre Patch Cord Lc-Lc Mm (50) Om4 Lszh Duplex Complete As Per Specification No. Wg-Coc/Fpc , Supplying And Plugging 3 M Fibre Patch Cord Lc-Lc Mm (50) Om3 Lszh Duplex Complete As Per Specification No. Wg-Coc/Fpc , Supplying And Laying Rigid Steel Conduit 16 Swg 32 Mm Dia. With Necessary Accessories In Rcc Work/False Ceiling/False Flooring As Per Specification No: WgMa/Cc. , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 90 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete. , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 75 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 50 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete. , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 120 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete. , Supplying And Installing, Testing & Commissioning Of Digital (Hybrid) Type Epabx Of 6 X 32 Extensions Suitable Upto 96 Extensions Complete. , Supplying And Fixing Wireless N 150 Desktop Adapter In Provided Computer As Per Specification No. Wg-Nas/Lanc2 , Supplying And Erecting Vpit Heavy Duty Copper Wound Ballast 230V For 80- 150W Hpsv/Mv/Mh As Per Specification No. Fg-Fg/As5. , Supplying And Erecting Vpit Compound Heavy Duty Copper Wound Ballast For 230V For 250W Hpsv/Mv/Mh As Per Specification No. Fg-Fg/As5. , Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 8 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background. , Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 6 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background. , Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 4 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background , Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 3 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background. , Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 2 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background. , Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 12 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background , Supplying And Erecting Unbreakable Concealed Type Modular Switch Box With Double Mounting Plate For 1 Module Duly Erected Flush To Wall With Required Chiselling And Finishing With Cement Mortar / Pop As Per Required To Match The Background , Supplying And Erecting Ultra Violet Water Purifier With Softener For Safe Drinking Water Consisting Of Uv Germicidal Tube Of 8W Capacity, Choke Made Of Copper Wire, Two Indicator Lamps, Dual Function Cartridge With Output Of Purified Water 1 Litre/Min With Activated Carbon Filter And Softener Operating On 230V, Single Phase A.C. Supply With Uv Fail & Filter Change Indication System. , Supplying And Erecting Ultra Violet Storage Type Water Purifier (Ro+Uv+Uf) With Softener For Safe Drinking Water Consisting Of Uv Germicidal Tube Of 8W Capacity Choke Made Of Copper Wire And Two Indicator Lamps With Output Of Purified Water Minimum 0.33 Litre/Min With Activated Carbon Filter And Softener Operating On 230V, Single Phase A.C. Supply With Uv Fail & Filter Change Indication System .(For Tds More Than 200) , Supplying And Erecting Two Pole Power Contactor 230 V, 32 A For Time Switch Complete Erected On Provided Wooden Block/ Box, With Necessary Materials. , Supplying And Erecting Two Pole Power Contactor 230 V, 12 A For Time Switch Complete Erected On Provided Wooden Block/ Box, With Necessary Materials. , Supplying And Erecting Two Pole Metal Clad Changeover Switch 240 V, 32 A Erected On Angle Iron/Gi Frame And Duly Connected With Suitable Wire Leads Complete , Supplying And Erecting Triple Pole Mini Feeder Pillar With 500V, 200A Fpmccb As Incomer And 2 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A With Aluminium Bus Bar Erected In 14 Swg Crca Sheet Box With Supporting Angles, Self Locks, Gasket Having Ip54,Ik10 Protection And Slanting Top To Be Erected On Provided Foundation Complete As Per Specification No. Sw , Supplying And Erecting T8 Fluorescent Tube Day Light 1200Mm, 36 W , Supplying And Erecting T5 24 W Energy Efficient Fluorescent Tube. , Supplying And Erecting Street Light Wall Bracket Made From 40 Mm. Dia ‘ G.I. Pipe 1.2 M. In Total Length Complete As Per Specification No. Fg-Bkt/Wb , Supplying And Erecting Street Light Wall Bracket Made From 25 Mm. Dia ‘ G.I. Pipe 1.2 M. In Total Length Complete As Per Specification No. Fg-Bkt/Wb , Supplying And Erecting Street Light Bracket Made From 40 Mm. Dia ‘B’ Class G.I. Pipe, 0.6M. In Length Along With Pole Cap Of 300 Mm Length And 80 Mm Dia Duly Welded With Provided Leads As Per Specification No. Fg-Bkt/Bpc , Supplying And Erecting Street Light Bracket For Erection Of Single Fitting Made From 40 Mm. Dia ‘B’ Class G.I. Pipe 1.0 M. In Length Along With Pole Cap Of 300 Mm Length 100 Mm Dia Duly Welded As Per Specification No. Fg-Bkt/Bpc , Supplying And Erecting Street Light Bracket For Erection Of Double Fitting Made From 40 Mm. Dia ‘B’ Class G.I. Pipe 1.0 M. In Length Along With Pole Cap Of 300 Mm Length 100 Mm Dia Duly Welded As Per Specification No. FgBkt/Bpc , Supplying And Erecting Storage Type Water Heater 50 Litres Capacity Having Standing Loss<0.675 Kwh/24Hour/45°C, High Impact Resistance Engineering Plastic Body With Anti Corrosive High Grade Steel Inner Tank Heating Element Having Hard Water & Corrosion Protection, With Minimum 3 Safety Protections (I.E. Thermostat & Thermal Cut-Out, Function Valve) With Total Pressure 8 Bar Withstanding Capacity Duly Tested And Marking Sr. No. And Date Of Erection Complete. Specification No.Ap-Wh/Stwh , Supplying And Erecting Storage Type Water Heater 25 Litres Capacity Having Standing Loss <0.511Kwh/24Hour/45°C, High Impact Resistance Engineering Plastic Body With Anti Corrosive High Grade Steel Inner Tank, Heating Element Having Hard Water & Corrosion Protection, With Minimum 3 Safety Protections (I.E. Thermostat & Thermal Function Cut-Out, Valve) With Total Pressure 8 Bar Withstanding Capacity Duly Tested And Marking Sr. No. And Date Of Erection Complete. Specification No. Ap-Wh/Stwh , Supplying And Erecting Storage Type Water Heater 15 Litres Capacity Having Standing Loss <0.419 Kwh / 24 Hour / 45°C, High Impact Resistance Engineering Plastic Body With Anti Corrosive High Grade Steel Inner Tank Heating Element Having Hard Water & Corrosion Protection, With Minimum 3 Safety Protections (I.E. Thermostat & Thermal Cut-Out, Multi Function Valve) With Total Pressure 8 Bar Withstanding Capacity Duly Tested And Marking Sr. No. And Date Of Erection Complete. Specification No. Ap-Wh/Stwh , Supplying And Erecting Steel Tubular Swaged Pole 165.1 X 139.7 X 114.3 Mm Dia With 4.5 X 4.5 X 3.65 Mm. Thickness (5+2.5+2.5 M) Length Respectively And Total 10 M Long With Pole Cap, Base Plate In Provided Foundation (Weight 160 Kg) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Steel Tubular Swaged Pole 165.1 X 139.7 X 114.3 Mm Dia With 4.5 X 4.5 X 3.65 Mm Thickness ( 5+2+2 M ) Length Respectively And Total 9 M Long With Pole Cap, Base Plate In Provided Foundation (Weight 147 Kg) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Steel Tubular Swaged Pole 139.7 X 114.3 X 88.9 Mm Dia With 4.5X3.65X3.25 Mm Thickness (5+1.75+1.75 M) Length Respectively And Total 8.5 M Long With Pole Cap, Base Plate In Provided Foundation. (Weight 109 Kg.) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Steel Tubular Swaged Pole 139.7 X 114.3 X 88.9 Mm Dia With 4.5X3.65X3.25 Mm Thickness (4.5+1.75+1.75 M) Length Respectively And Total 8.0 M Long With Pole Cap, Base Plate In Provided Foundation. (Weight 101 Kg) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Steel Tubular Swaged Pole 139.7 X 114.3 X 88.9 Mm Dia With 4.5 X 3.65 X 3.25 Mm Thickness (5+2+2 M ) Length Respectively And Total 9 M Long With Pole Cap, Base Plate In Provided Foundation (Weight 113 Kg) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Static Energy Meter With 3 X 240V 50 Hz. Ac Supply 10 To 60 A, Isi Mark, Accuracy Class 1.0 With Backlit Lcd Display, (Measuring And Display Trivector, V, I, Kw, Pf, Hz, Last Month History Of Kwh And Md In Kw) With Special Features Like Tod, Tamper Logging, Optical Communication Port & Display In Absence Of Power & With Transparent Hinge Type Box Complete Erected On Polished Teak Wood Board Duly Wired With Required Size Of Weather Proof Pvc Wires Duly Tested By Electric Supply Company. , Supplying And Erecting Single Pole And Neutral Distribution Board (Spndb), With 2 Ways For Incoming And 6 Ways (6 Poles) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface / Flush Mounted, Ip 43 Protection On Iron / Gi Frame As Per Specification No. Sw-Swr/Mcbdb , Supplying And Erecting Single Pole And Neutral Distribution Board (Spndb), With 2 Ways For Incoming And 2 Ways (2 Poles) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface / Flush Mounted, Ip 43 Protection On Iron / Gi Frame As Per Specification No. Sw-Swr/Mcbdb , Supplying And Erecting Single Pole And Neutral Distribution Board (Spndb), With 2 Ways For Incoming And 10 Ways (10 Poles) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface / Flush Mounted, Ip 43 Protection On Iron / Gi Frame As Per Specification No. Sw-Swr/Mcbdb , Supplying And Erecting Shockproof T. Switch 16 A Porcelain Base Surface Mounting Type / Flush Mounting Type Erected On Filled Polypropylene Board Or Polished Thick Varnished Double Wooden Block/Folded Or Screwed Board With Top Of Either Wooden/ 3 Mm Thick Hylam Sheet/ 4Mm Thick Plywood Pasted With 1.5 Mm Thick Laminate With S M Screws And Duly Connected. , Supplying And Erecting Shockproof Piano Type Switch 250 V, 16 A, Erected On Filled Polypropylene Board Or Polished Double Wooden/ Folded Or Screwed Board With Top Of Either Wooden/ 3 Mm Thick Hylam Sheet/ 4Mm Thick Plywood Pasted With 1.5 Mm Thick Laminate With S M Screws And Duly Connected. , Supplying And Erecting Shockproof Bell Push On Filled Polypropylene Board Or Wooden Block Covered With Sunmica With 2 Core (Trs Type) Pvc Insulated Copper Wire Of Size 0.5 Sq Mm 5 M Length Connected To The Point. , Supplying And Erecting Shockproof 6A Porcelain Base T.Switch / Bell Push Erected On Filled Polypropylene Board Or Polished Double Wooden Block / 3 Mm Thick Hylam Sheet / 4Mm Thick Plywood Pasted With 1.5 Mm Thick Laminate With S M Screws And Duly Connected , Supplying And Erecting Shockproof 3 Pin Plug Socket 6A With Porcelain Base / Flush Type Erected On Filled Polypropylene Board Or Polished Thick Varnished Double Wooden Block / Folded Or Screwed Board With Top Of Either Wooden / 3 Mm Thick Hylam Sheet/ 4Mm Thick Plywood Pasted With 1.5 Mm Thick Laminate With S M Screws And Duly Connected. , Supplying And Erecting Shockproof 3 Pin Plug Socket 16A With Porcelain Base/ Flush Type Erected On Filled Polypropylene (Is:14772-2000) Board Or Polished Thick Varnished Double Wooden Block / Folded Or Screwed Board With Top Of Either Wooden/3 Mm Thick Hylam Sheet/ 4Mm Thick Plywood Pasted With 1.5 Mm Thick Laminate With S M Screws And Duly Connected. , Supplying And Erecting Rigid Steel Conduit 16 Swg 32 Mm Dia. With Necessary Accessories In Wall/Floor With Chiselling Appropriately As Per Specification No: Wg-Ma/Cc. , Supplying And Erecting Rigid Steel Conduit 16 Swg 25 Mm Dia. With Necessary Accessories In Wall/Floor With Chiselling Appropriately As Per Specification No: Wg-Ma/Cc. , Supplying And Erecting Regular/ Standard Model Ceiling Fan Of 900 /1050 Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn/Cf , Supplying And Erecting Regular/ Standard Model Ceiling Fan Of 1400Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn/Cf , Supplying And Erecting Rectangular Shaped Led Panel Light(1200Mm X 300Mm) Max. 35 W Having Crca Powder Coated Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 4200 Lumens, Min. Efficacy Of 120 Lumen/W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty. , Supplying And Erecting Recess Type, 3 Pin Plug Socket 6A With Piano Switch 6A Erected On M.S Box Made Of 16 Swg Sheet Duly Painted And Covered With Bakelite Hylam Sheet Of 3 Mm Thickness Connected With Earth Terminals And Leads Duly Concealed , Supplying And Erecting Recess Type, 3 Pin Plug Socket 6A With Piano Switch 6 A Combined Unit Erected On Polished Double Wooden Block/ Folded Or Screwed Board With Top Of Either Wooden Or Plywood Pasted With Sunmica And With Connecting Leads , Supplying And Erecting Quartz Electronic Time Switch Having 24 Hour Dial To Work On 250 V 50 Cycle Ac Having Built In Rechargeable Nickel Cadmium Batteries To Run The Time Switch On Failure Of Supply Having Switch Contact Rating Up To 16A To Use Independently Or In Conjunction With Contactor. , Supplying And Erecting Pvc Trunking (Pvc Casing-N-Capping) Of Size 40 Mm With Accessories On Wall/Ceiling As Per Specification No: Wg-Ma/Con. , Supplying And Erecting Pvc Trunking (Pvc Casing-N-Capping) Of Size 32 Mm With Accessories On Wall/Ceiling As Per Specification No: Wg-Ma/Con , Supplying And Erecting Pvc Trunking (Pvc Casing-N-Capping) Of Size 25 Mm With Accessories On Wall/Ceiling As Per Specification No: Wg-Ma/Con. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 6 Module Duly Erected , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 4 Module Duly Erected. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 3 Module Duly Erected. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 2 Module Duly Erected. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 16 / 18 Module Duly Erected. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 12 Module Duly Erected. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 1 Module Complete Duly Erected. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting & Front Plate For 8 Module Complete Duly Connected. , Supplying And Erecting Pvc Surface Modular Double Mounting Plate 8 Module Complete Duly Erected. , Supplying And Erecting Pvc Surface Modular Double Mounting Plate 6 Module Complete Duly Erected. , Supplying And Erecting Pvc Surface Modular Double Mounting Plate 4 Module Complete Duly Erected , Supplying And Erecting Pvc Surface Modular Double Mounting Plate 3 Module Complete Duly Erected. , Supplying And Erecting Pvc Surface Modular Double Mounting Plate 2 Module Complete Duly Erected. , Supplying And Erecting Pvc Surface Modular Double Mounting Plate 16/18 Module Complete Duly Erected. , Supplying And Erecting Pvc Surface Modular Double Mounting Plate 12 Module Complete Duly Erected , Supplying And Erecting Pvc Surface Modular Double Mounting Plate 1 Module Complete Duly Erected. , Supplying And Erecting Pvc Slotted Box Trunking Of Size 75X75 Mm. With Accessories On Wall/Ceiling As Per Specification No: Wg-Ma/Slbox. , Supplying And Erecting Pvc Slotted Box Trunking Of Size 45X30 Mm. With Accessories On Wall/Ceiling As Per Specification No: Wg-Ma/Slbox. , Supplying And Erecting Pvc Slotted Box Trunking Of Size 100X100 Mm. With Accessories On Wall/Ceiling As Per Specification No: Wg-Ma/Slbox. , Supplying And Erecting Pvc Box Trunking Of Size 75X75 Mm. With Accessories On Wall/Ceiling As Per Specification No: Wg-Ma/Box. , Supplying And Erecting Pvc Box Trunking Of Size 100X50 Mm. With Accessories On Wall/Ceiling As Per Specification No: Wg-Ma/Box . , Supplying And Erecting Programmable Digital Almanac Timer Microcontroller Based With Real Time Clock To Operate On Derived Switching “On” And Switching “Off” Street Light As Per Daily Sunset And Sunrise Respectively Automatically Having 4 Digit Led Continuous Time Display, Relay Output 230 V / 10A With 10 Hrs. Battery Backup And Manual Over Drive Facility Capable To Drive Different Capacity Contactors Timer Erected In Provided M.S. Box. , Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 63A Erected On Polished Wooden Block. , Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 32A Erected On Polished Wooden Block. , Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 200A Erected On Polished Wooden Block. , Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 16A Erected On Polished Wooden Block. , Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 100A Erected On Polished Wooden Block. , Supplying And Erecting Pole Clamp Made From 50X6mm Ms Flat For Pole Or Pipe, Post Erected With 15Mm Bolts And Nuts Duly Painted With One Coat Of Red Oxide And Two Coats Of Aluminium Paint Complete. , Supplying And Erecting Pole Clamp Made From 50X10mm Ms Flat For Pole Or Pipe, Post Erected With 15Mm Bolts And Nuts Duly Painted With One Coat Of Red Oxide And Two Coats Of Aluminium Paint Complete. , Supplying And Erecting Plywood 6 Mm Thick Fixed To Wall Or On Provided Panel Board With Necessary Materials Such As Screws, Wall Fasteners Supports, Nuts Bolts Etc. Complete. , Supplying And Erecting Plywood 12 Mm Thick Fixed To Wall Or On Provided Panel Board With Necessary Materials Such As Screws, Wall Fasteners Supports, Nuts Bolts Etc. Complete. , Supplying And Erecting Outdoor Stand Mounted Feeder Pillar For High-Mast Of The Same Manufacturer With 63A Tpn Mcb Incomer, 24Hr Astronomical Time Switch With Minimum 5 Years Battery Backup, , Ip 54 And Ik10 Protection, 45 A Tp Contactor For Automatic Switching Of Luminaires, 2 No 9A Contactors And Raise/Lower Push Button, And Provision For Termination Of Adequate Size Of Incoming And Outgoing Cables Complete Erected In Min. 14 Swg Crca Sheet Box Powder Coated With Supporting Angles, Self Lock, Gasket And Slanting Top Erected On Cc Foundation Complete. , Supplying And Erecting Outdoor Stand Mounted Feeder Pillar For High-Mast Of The Same Manufacturer With 32A Tpn Mcb Incomer, 24Hr Astronomical Time Switch With Minimum 5 Years Battery Backup, Ip 54 And Ik10 Protection, 25 A Tp Contactor For Automatic Switching Of Luminaires, 2 No. 9A Contactors And Raise/Lower Push Button, And Provision For Termination Of Adequate Size Of Incoming And Outgoing Cables Complete Erected In Min. 14 Swg Crca Sheet Box With Supporting Angles, Self Lock, Gasket And Slanting Top Erected On Cc Foundation Complete. , Supplying And Erecting One/Two Way Piano Type Switch 6A./Bell Push Erected On Filled Polypropylene Board Or Double Polished Wooden Board/ Folded Or Screwed Board With Top Of Either Wooden/ 3 Mm Thick Hylam Sheet/ 4Mm Thick Plywood Pasted With 1.5 Mm Thick Laminate With S M Screws And Duly Connected. , Supplying And Erecting Modular Type Two Way Switch 6A / 10A (2 Module), Duly Erected On Provided Plate And Box With Wiring Connections Complete , Supplying And Erecting Modular Type Telephone Socket Two Gang With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erecting Modular Type Telephone Socket One Gang With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete , Supplying And Erecting Modular Type T.V. Socket Single Outlet, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erecting Modular Type Switch One Way 16 / 20 A, Duly Erected On Provided Plate And Box With Wiring Connections Complete With Neon Indicator. , Supplying And Erecting Modular Type Switch 6A / 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erecting Modular Type Switch 16A Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erecting Modular Type Indicator Lamp, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erecting Modular Type D.P. Switch 32A With Indicator, Duly Erected On Provided Plate And Box With Wiring Connections Complete , Supplying And Erecting Modular Type Buzzer 220 / 250V, Duly Erected On Provided Plate And Box With Wiring Connections Complete , Supplying And Erecting Modular Type Blanking Plate Two Module, Duly Erected On Provided Plate & Box , Supplying And Erecting Modular Type Bell-Push With Indicator 2 Modules 6A / 10A, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erecting Modular Type Bell-Push 6A / 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erecting Modular Type Bell Indicator, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erecting Modular Type 6 / 16A Fuse Unit, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erecting Modular Type 32A, Dp Key Tag Switch With Key Tag, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erecting Modular Type 3 Pin 6A Multi Socket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections , Supplying And Erecting Modular Type 3 Pin 6 / 16A Multi Socket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erecting Modular Type (Two Module) Electronic Step Regulator For Fan, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erecting Modular Type (Two Module) Electronic Dimmer 600/650W, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erecting Modular Type (Two Module) Electronic Dimmer 1000W, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erecting Modular Type (One Module) Electronic Dimmer 400 / 450W, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erecting Metal Work In Crca Sheet Including Iron Work For Supports With Fabrication Of Boxes, Panel Boards, Etc. Including Cutting, Bending, Drilling, Welding, Riveting, Treated With Anti-Rust Treatment And Duly Powder Coated Or Painted With One Coat Of Red Lead Paint And 2 Coats Of Enamel Paint Complete , Supplying And Erecting Metal Halide Lamp Double Ended 230V, 70 W . , Supplying And Erecting Metal Halide Lamp Double Ended 230V, 250 W. , Supplying And Erecting Metal Halide Lamp Double Ended 230V, 150 W . , Supplying And Erecting Marine (Waterproof) Plywood 18/19 Mm Thick Fixed To Wall Or On Provided Panel Board With Necessary Materials Such As Screws, Wall Fasteners, Supports, Nut Bolts Etc. Complete With Compliance To Is 720:2010 , Supplying And Erecting Mains With Wp 4 X 4 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erected With Required Size Of Porcelain Reel Insulators And 16 Swg G.I. Binding Wire. , Supplying And Erecting Mains With Wp 3 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erected With Required Size Of Porcelain Reel Insulators And 16 Swg G.I. Binding Wire. , Supplying And Erecting Mains With Wp 3 X 4 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erected With Required Size Of Porcelain Reel Insulators And 16 Swg G.I. Binding Wire. , Supplying And Erecting Mains With Wp 2 X 4 Sq. Mm. 1100 V Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erected With Required Size Of Porcelain Reel Insulators And 16 Swg G.I. Binding Wire. , Supplying And Erecting Mains With Wp 2 X 2.5 Sq. Mm. 1100 V Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erected With Required Size Of Porcelain Reel Insulators And 16 Swg G.I. Binding Wire. , Supplying And Erecting Mains With 4X25 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places As Per Specification No: Wg-Ma/Bw , Supplying And Erecting Mains With 4X16 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places As Per Specification No: Wg-Ma/Bw , Supplying And Erecting Mains With 3X6 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places As Per Specification No: Wg-Ma/Bw , Supplying And Erecting Mains With 3X4 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places As Per Specification No: Wg-Ma/Bw , Supplying And Erecting Mains With 3X2.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places As Per Specification No: Wg-Ma/Bw , Supplying And Erecting Mains With 2X6 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places. As Per Specification No: Wg-Ma/Bw , Supplying And Erecting Mains With 2X4 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places. As Per Specification No: Wg-Ma/Bw , Supplying And Erecting Mains With 2X2.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places. As Per Specification No: Wg-Ma/Bw , Supplying And Erecting Mains With 2X1.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places As Per Specification No: Wg-Ma/Bw , Supplying And Erecting M.S. Pipe Pole ‘B’ Class 80 Mm Dia 6 M Long With Pole Cap, Base Plate In Provided Foundation As Per Specification No. Oh-Pl/Gip , Supplying And Erecting Luminous / Modular Type Call Bell Indicator With Plastic Body, Heavy Duty Coil And Indicator Lamp Working On 230V A.C. Supply With Resetting Arrangement Complete Erected On Double Wooden/ Sunmica Board. , Supplying And Erecting Lszh Armoured Multimode Optical Fibre Cable With 6 Fibres, Core Dia 50/125 ?M (Om4) Suitable Up To 10 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall/Ceiling Or Laid In Provided Pipe/Trench As Per Specification No. Wg-Coc/Ofc , Supplying And Erecting Led Strip Light 5M Length Max. 95 W Ip20 Class Having Minimum Lumens Output Of 1600 Lumens/M, Min. Efficacy Of 90 Lumen/W, Cri>80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd0.95, Operating Range Of 230-270V, Life Class Of 30,000 Hrs. At L70b50 Including Driver With 1 Year Warranty. , Supplying And Erecting Led Strip Light 5M Length Max. 45 W Ip20 Class Having Minimum Lumens Output Of 800 Lumens/M, Min. Efficacy Of 90 Lumen/W, Cri>80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd0.95, Operating Range Of 230-270V, Life Class Of 30,000 Hrs. At L70b50, Including Driver With 1 Year Warranty. , Supplying And Erecting Led Square / Circular Max. 7W Down Lighter/ Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 770 Lumens, Min. Efficacy Of 110 Lumen/W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty. , Supplying And Erecting Led Square / Circular Max. 25 W Down Lighter/ Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 2750 Lumens, Min. Efficacy Of 110 Lumen/W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty , Supplying And Erecting Led Square / Circular Max. 18 W Down Lighter/ Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 2000 Lumens, Min. Efficacy Of 110 Lumen/W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty , Supplying And Erecting Led Square / Circular Max. 14 W Down Lighter/Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 1500 Lumens, Min. Efficacy Of 110 Lumen/W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty , Supplying And Erecting Led Square / Circular Max. 11 W Down Lighter/Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 1200 Lumens, Min. Efficacy Of 110 Lumen/W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty. , Supplying And Erecting Led Panel Light(600Mm X 600Mm) Max. 35 W Having Crca Powder Coated Housing, Polystyrene Diffuser Having System Lumens Output Of Min 4200 Lumens, Min. Efficacy Of 120 Lumen/W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs. At L70b50 Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty , Supplying And Erecting Led Panel Light(600Mm X 600Mm) Max. 30 W Having Crca Powder Coated Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 3600 Lumens, Min. Efficacy Of 120 Lumen/W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs. At L70b50 Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty , Supplying And Erecting Integrated Led Street Light Fitting 85-90W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 9300 Lumens, Min. Efficacy Of 110 Lumen/W, Cri>70, Cct Upto 6500K, Thd0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification No Fg-Odf/Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 70-75W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 7700 Lumens, Min. Efficacy Of 110 Lumen/W, Cri>70, Cct Upto 6500K,Thd0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification No Fg-Odf/Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 60W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 6600 Lumens, Min. Efficacy Of 110 Lumen/W, Cri>70, Cct Upto 6500K, Thd0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification No Fg-Odf/Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 40 To 50W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 4400 Lumens, Min. Efficacy Of 110 Lumen/W, Cri>70, Cct Upto 6500K,Thd0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification No Fg-Odf/Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 26 To 30W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing , Having System Lumens Output Of Min. 2600 Lumens, Min. Efficacy Of 100 Lumen/W, Cri>70, Cct Upto 6500K, Thd0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification No Fg-Odf/Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 23 To 25W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 2300 Lumens, Min. Efficacy Of 100 Lumen/W, Cri>70, Cct Upto 6500K, Thd0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver Complete With 3Years Warranty As Per Specification No Fg-Odf/Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 18 To 22W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 1800 Lumens, Min. Efficacy Of 100 Lumen/W, Cri>70, Cct Upto 6500K, Thd0.95, Operating Range Of 140- 270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification No Fg , Supplying And Erecting Integrated Led Street Light Fitting 160-170W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 19000 Lumens, Min. Efficacy Of 120 Lumen/W, Cri>70, Cct Upto 6500K, Thd0.95, Operating Range Of 140- 270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification No FgOdf/Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 120W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 13000 Lumens, Min. Efficacy Of 110 Lumen/W, Cri>70, Cct Upto 6500K,Thd0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification No Fg-Odf/Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 100-110W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 11000 Lumens, Min. Efficacy Of 110 Lumen/W, Cri>70, Cct Upto 6500K, Thd0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification No Fg-Odf/Fls2. , Supplying And Erecting Integrated Led Post Top 45W Ip65 & Ik10 Class Having Die Cast Aluminium Housing With Uv Protected Polycarbonate Diffuser, Having System Lumens Output Of Min.4500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri>80, Cct Upto 6500K, Thd0.90, Operating Range Of 140-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 30,000 Hrs. At L50b50 , Including Driver Complete With 2 Year Warranty As Per Specification No FgOdf/Fls , Supplying And Erecting Integrated Led Highbay Fitting 135W Ip65 & Ik08 Class Having Die Cast Aluminium Housing With Polycarbonate Diffuser With Integrated Optics, Having System Lumens Output Of Min. 20000 Lumens, Min. Efficacy Of 145 Lumen/W, Cri>70, Cct Upto 6500K, Thd0.90, Operating Range Of 140-240V, Inbuilt Surge Protection Of 4Kv, Life Class Of 50,000 Hrs. At L50b50 , Including Driver Complete With 3 Year Warranty As Per Specification No Fg-Odf/Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 70W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 8400 Lumens, Min. Efficacy Of 120 Lumen/W, Cri>70, Cct Upto 6500K, Thd0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf/Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 50W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 5000 Lumens, Min. Efficacy Of 100 Lumen/W, Cri>70, Cct Upto 6500K, Thd0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf/Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 30W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 3000 Lumens, Min. Efficacy Of 100 Lumen/W, Cri>70, Cct Upto 6500K, Thd0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf/Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 195W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 23400 Lumens, Min. Efficacy Of 120 Lumen/W, Cri>70, Cct Upto 6500K, Thd0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf/Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 155W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 18600 Lumens, Min. Efficacy Of 120 Lumen/W, Cri>70, Cct Upto 6500K, Thd0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf/Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 120W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min.14500 Lumens, Min. Efficacy Of 120 Lumen/W, Cri>70, Cct Upto 6500K, Thd0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf/Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 100W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 12000 Lumens, Min. Efficacy Of 120 Lumen/W, Cri>70, Cct Upto 6500K, Thd0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50,000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf/Fls2. , Supplying And Erecting Integrated Led Bollard Cylindrical/Cubical Shaped 800Mm 8W Ip65 & Ik10 Class Having Extrusion Aluminium Housing With Polycarbonate Diffuser, Having System Lumens Output Of Min. 800 Lumens, Min. Efficacy Of 100 Lumen/W, Cri>80, Cct Upto 6500K, Thd0.90, Operating Range Of 140-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 25,000 Hrs. At L50b50, Including Driver Complete With 2 Year Warranty As Per Specification No Fg-Odf/Fls2. , Supplying And Erecting Integrated Led Bollard Cylindrical/Cubical Shaped 500Mm 8W Ip65 & Ik10 Class Having Extrusion Aluminium Housing With Polycarbonate Diffuser, Having System Lumens Output Of Min. 800 Lumens, Min. Efficacy Of 100 Lumen/W, Cri>80, Cct Upto 6500K, Thd0.90, Operating Range Of 140-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 25,000 Hrs. At L50b50, Including Driver Complete With 2 Year Warranty As Per Specification No Fg-Odf/Fls2. , Supplying And Erecting Ignitor Suitable For 230V Hpsv Lamp 70/150/250/400W As Specification No. Fg-Fg/As6 , Supplying And Erecting Hpsv Lamp 3 Pin Bc/Screwed Cap Head /Pin Type 230V, 70 W Son-T-Type. , Supplying And Erecting Hpsv Lamp 3 Pin Bc/Screwed Cap Head /Pin Type 230V, 250 W Son-T-Type. , Supplying And Erecting Hpsv Lamp 3 Pin Bc/Screwed Cap Head /Pin Type 230V, 250 W Son Type. , Supplying And Erecting Hpsv Lamp 3 Pin Bc/Screwed Cap Head /Pin Type 230V, 150 W Son-T-Type. , Supplying And Erecting Hpsv Lamp 3 Pin Bc/Screwed Cap Head /Pin Type 230V, 150 W Son Type. , Supplying And Erecting Hpsv Lamp 3 Pin Bc/Screwed Cap Head / Pin Type 230V, 70 W Son Type. , Supplying And Erecting Hms Pvc Conduit Frls Grade 32 Mm Dia. With Pvc Accessories On Wall / Ceiling As Per Specification No: Wg-Ma/Con. , Supplying And Erecting Hms Pvc Conduit Frls Grade 32 Mm Dia. With Necessary Accessories In Wall/Floor With Chiselling Appropriately As Per Specification No: Wg-Ma/Cc. , Supplying And Erecting Hms Pvc Conduit Frls Grade 25 Mm Dia. With Pvc Accessories On Wall /Ceiling As Per Specification No: Wg-Ma/Con. , Supplying And Erecting Gi Wire Of High Purity Of Required Sizes Used For Earthing Or Any Other Purposes On Wall With Necessary G. I. Clamps Fixed On Wall/Cable/ Conduit With Screws Complete. , Supplying And Erecting Gi Strip Of High Purity Required Size Used For Earthing On Wall And/Or Any Other Purpose With Necessary Gi Clamps Fixed On Wall Painted With Bituminous Paint With Joints Required. As Per Specification No Ea-Ep. , Supplying And Erecting Gi Sheet 0.8 Mm (22 Swg) Having Zinc Coating Of 275 Microns With Galvanization Process Compliance To Is 2629:1985 To Be Used For Fabrication Of Boxes Panel Boards Etc. Including Cutting, Bending, Drilling, Welding, Riveting Etc. And Painting With One Coat Of Red Lead Paint And 2 Coats Of Enamel Paint. , Supplying And Erecting Gi Sheet 0.6 Mm (24 Swg) Having Zinc Coating Of 275 Microns With Galvanization Process Compliance To Is 2629:1985 To Be Used For Fabrication Of Boxes Panel Boards Etc. Including Cutting, Bending, Drilling, Welding, Riveting Etc. And Painting With One Coat Of Red Lead Paint And 2 Coats Of Enamel Paint. , Supplying And Erecting Gate/Garden Light Fitting With 300Mm Dia. Glass Bowl Suitable For Upto 12W Led Lamp On Provided Pipe As Per Specification No. Fg , Supplying And Erecting G.I. Stay Set For Poles, Including Loop Insulators At Inaccessible Height With Anchor Plate 300X300x6mm., Straining Screws, G.L. Stay Wire 7/10 Swg, G.L. Stay Rod 20Mmx1.8M Length And Pole Clamps Duly Erected In Provided Cement Concrete Foundation Complete. , Supplying And Erecting G.I. Stay Set For Poles, Including Loop Insulators At Inaccessible Height With Anchor Plate 300X300x6 Mm., Straining Screws, G.L. Stay Wire 7/8 Swg, G.L. Stay Rod 20Mmx1.8M Length And Pole Clamps Duly Erected In Provided Cement Concrete Foundation Complete. , Supplying And Erecting G.I. Self Stay Set For Pole, Including Anchor Plate 300X300x6mm Straining Screw, Loop-Insulator, G.L. Stay Wire 7/10 Swg, G.L. Stay Rod 20Mmx1.8M Long, Erected With Pole Clamps Along With Angle Iron Bracket Of 50X50x6mm And One Meter Long Fixed To Pole At Suitable Height With Suitable Ms Clamps Duly Erected In Provided C.C. Foundations Complete. , Supplying And Erecting G.I. Pipe Pole ‘B’ Class 80 Mm Dia 6 M Long With Pole Cap, Base Plate In Provided Foundation As Per Specification No. Oh-Pl/Gip , Supplying And Erecting G.I. Pipe ‘C’ Class Erw 75/80 Mm Dia With Necessary Fittings Complete As Per Specification No. Ff-Pp , Supplying And Erecting G.I. Pipe ‘C’ Class Erw 65 Mm Dia With Necessary Fittings Complete As Per Specification No. Ff-Pp , Supplying And Erecting G.I. Pipe ‘C’ Class Erw 20 Mm Dia With Necessary Fittings Complete As Per Specification No. Ff-Pp , Supplying And Erecting G.I. Fly Stay Set For Pole Including Straining Screw, G.L. Stay Wire, 7/10 Swg (For To 15M Long) With Pole Clamp, Made Of 50X6mm Ms Flat, Erected On Provided Rsj Pole Complete. (Add. Rs. 25/- Per M For Extra Length Beyond 15 M) , Supplying And Erecting Fully Automatic Line Voltage Stabilizer Buck And Boost Type For Operation On Input Voltage 160-270V And Output Voltage 200-250V Rated For, 1Kva Maximum Load And With Voltmeter, Selector Switch, 6A/16A Flush Type 3 Pin Socket For Output And With 3 Core Copper Flexible Cord And 3 Pin 6/16A Plug Top Suitable For With Overload & Short Circuit Protection Complete. , Supplying And Erecting Fully Automatic Line Voltage Stabilizer Buck And Boost Type For Operation On Input Voltage 160-270V And Output Voltage 200-250V Rated For 4Kva Maximum Load And With Voltmeter, Selector Switch, 6A/16A Flush Type 3 Pin Socket For Output And With 3 Core Copper Flexible Cord And 3 Pin 6/16A Plug Top With Overload & Short Circuit Protection Complete. , Supplying And Erecting Fully Automatic Line Voltage Stabilizer Buck And Boost Type For Operation On Input Voltage 160-270V And Output Voltage 200-250V Rated For 3Kva Maximum Load And With Voltmeter, Selector Switch, 6A/16A Flush Type 3 Pin Socket For Output And With 3 Core Copper Flexible Cord And 3 Pin 6/16A Plug Top With Overload & Short Circuit Protection Complete. , Supplying And Erecting Fresh Air Cum Exhaust Fan Of Light Duty 250 V A.C. 50 Cycles 300Mm. 1400 Rpm Rust Proof Body & Blades, Wire Mesh, Duly Erected, Complete. , Supplying And Erecting Fresh Air Cum Exhaust Fan Of Light Duty 250 V A.C. 50 Cycles 225Mm. 1400 Rpm Rust Proof Body & Blades, Wire Mesh, Duly Erected, Complete. , Supplying And Erecting Four Pole Power Contactor 430 V, 40 A For Time Switch Complete Erected On Provided Wooden Block/ Box, With Necessary Materials. , Supplying And Erecting Four Pole Power Contactor 430 V, 16 A For Time Switch Complete Erected On Provided Wooden Block/ Box, With Necessary Materials. , Supplying And Erecting Flush, Shock Proof Plug Socket 6 Pin 6A And 16A With Switch 16A Combined Unit Erected In Recess In 16 Gauge M.S Sheet Box Duly Painted And Connected With Earth Terminal And Leads , Supplying And Erecting Flush Type, Shockproof Plug Socket 6 Pin 6A And 16A With Switch 16A Combined Unit Erected On Filled Polypropylene Board Or Double Wooden Block / 3Mm Thick Hylam Sheet / 4Mm Thick Plywood Pasted With 1.5 Mm Thick Sunmica With S M Screws And Duly Connected. , Supplying And Erecting Flush Type Shockproof Plug Socket 6A & 16A (6 Pin) With 16A Switch Combined With Indicator Lamp And Fuse With Gang Box On Wooden Board. , Supplying And Erecting Exhaust Fan Medium Duty 230 V A.C. 50 Cycles 225 Mm. 1400 Rpm With Condenser Complete Erected In Position With Necessary Materials. Fan Motor With Moisture Proof Treatment And ‘E’ Class Insulation. , Supplying And Erecting Exhaust Fan Heavy Duty 230 V, A.C. 50 Cycles 375/380 Mm. 900 Rpm Complete Erected In Position As Per Specification No. Fg-Fn/Exf , Supplying And Erecting Exhaust Fan Heavy Duty 230 V A.C. 50 Cycles 450 Mm. 900 Rpm Complete Erected In Position As Per Specification No. Fg-Fn/Exf , Supplying And Erecting Exhaust Fan Heavy Duty 230 V A.C. 50 Cycles 450 Mm. 1400 Rpm Complete Erected In Position As Per Specification No. Fg-Fn/Exf , Supplying And Erecting Exhaust Fan Heavy Duty 230 V A.C. 50 Cycles 375/380 Mm. 1400 Rpm Complete Erected In Position As Per Specification No. Fg , Supplying And Erecting Energy Saving Ceiling Fan 230 V A.C. 50 Cycles 1200 Mm Complete Erected In Position As Per Specification No. Fg-Fn/Cf , Supplying And Erecting Energy Saving Bldc Ceiling Fan 230 V A.C. 50 Cycles 1200 Mm, Max. Energy Consumption Of 28W Having Service Ratio (Cmm/W) Of Min. 8 , Pf>0.9, Thd , Supplying And Erecting Electronic Type Step Regulator For Ceiling Fan 600/ 900/ 1200/ 1400 Mm. Sweep, Complete Erected On Provided Switch Board. , Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings Upto 25W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 76W100W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Th , Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 46W75W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<1 , Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 26W45W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And , Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 151W200W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 101W150W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd , Supplying And Erecting Electronic Ignitor Suitable For 230V Metal Halide Lamp 70/150/250/400W (Integral Or Non Integral Type Luminaires As Specification No. Fg-Fg/As6 , Supplying And Erecting Ding Dong / Electronic Musical Type Call Bell With Heavy Duty Coil Suitable To Operate On 230V A.C. Supply Erected On Polished Double Wooden Block/Sunmica Block Of Suitable Size. , Supplying And Erecting Copper Strip Of High Purity Required Size Used For Earthing On Wall And/Or Any Other Purpose With Necessary Copper Clamps Fixed On Wall Painted With Bituminous Paint With Joints Required. As Per Specification No. EaEp. , Supplying And Erecting Control Gear For Non Integral Flood Light Fittings Suitable For 2X250w Hpsv/Mh Lamp With All Accessories Complete. , Supplying And Erecting Control Gear For Non Integral Flood Light Fittings Suitable For 1X400w Hpsv/Mh Lamp With All Accessories Complete. , Supplying And Erecting Condenser For Mv/Sv/Mh Lamp 250W,230V As Specification No. Fg-Fg/As7 , Supplying And Erecting Condenser For Mv/Sv/Mh Lamp 150W,230V As Per Specification No. Fg-Fg/As7 , Supplying And Erecting Ceiling Rose / Batten Holder / Slanting Holder / Hanging Cord Switch / Hanging Bell Push / Pendant Holder Bakelite Base 6A. Erected On Filled Polypropylene Board Or Polished Double Wooden Block/ Pvc Junction Box. , Supplying And Erecting Cabin Fan Of A.C. 230 V. 50 Cycles 400 Mm. Sweep Complete With Necessary Brackets For Fixing Cabin Fans, Wire Etc. , Supplying And Erecting Cabin Fan Of A.C. 230 V. 50 Cycles 250 Mm. /300 Mm. Sweep Complete With Necessary Brackets For Fixing Cabin Fans, Wire Etc. , Supplying And Erecting C Type (Half) Clamps For Pole Made From 50X6mm Flat For Fixing Cross Arms By Means Of 15Mm Bolts And Nuts Painted With One Coat Of Red Oxide And Two Coats Of Aluminium Paint Complete. , Supplying And Erecting C Type (Half) Clamps For Pole Made From 50X10mm Flat For Fixing Cross Arms By Means Of 15Mm Bolts And Nuts Painted With One Coat Of Red Oxide And Two Coats Of Aluminium Paint Complete. , Supplying And Erecting Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 Rpm. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Speed Regulator And Moisture Proof Treatment To Winding And With ‘E’ Class Insulation. , Supplying And Erecting Annealed Bare Copper Wire Of High Purity Of Required Sizes Used For Earthing On Wall With Necessary Copper Clamps Fixed On Wall/Cable/Conduit With Screws Complete. , Supplying And Erecting Aluminium Strip Of High Purity Required Sizes Used For Earthing On Wall And/Or Any Other Purpose With Necessary Aluminium Clamps Fixed On Wall Painted With Bituminous Paint With Joints Required As Per Specification No Ea-Ep. , Supplying And Erecting Air Circulator 450 Mm. Sweep Oscillating Type, Wall Mounting 1440 Rpm With Speed Regulator, Overheat Protection Unit, Totally Enclosed, Flame Proof Motor Suitable For 230/250 Volts Single Phase, 50 Cycles A.C. Supply, With One Meter Of 3 Core Lead Wire And With Moisture Proof Treatment To Winding And With ‘E’ Class Insulation. , Supplying And Erecting Acrylic Sheet 3 Mm Thick To Be Used For Covering The Crca Sheet Boxes Etc. Including Cutting, Drilling, And Pasting Or Fixing With Nut Bolts/ Screws Etc. Complete. , Supplying And Erecting 75 Kvar, 440 V 3 Phase, 50 Hz., Contactor Logic & Intelligent Relay Micro Apfc Passive Filter Panel, Consisting Of Suitable Steps Of App/Mpp Type Capacitor Units With Detuned (Harmonic Filter) Reactors Of Suitable Rating , Apfc Panel Shall Be Compliance To Iec 61439 And Power Quality Iec 61921 Standard As Per Specification No Cp-Ed/Apfc , Supplying And Erecting 50 Kvar, 440 V 3 Phase, 50 Hz., Contactor Logic & Intelligent Relay Micro Apfc Passive Filter Panel, Consisting Of Suitable Steps Of App/Mpp Type Capacitor Units With Detuned (Harmonic Filter) Reactors Of Suitable Rating , Apfc Panel Shall Be Compliance To Iec 61439 And Power Quality Iec 61921 Standard As Per Specification No Cp-Ed/Apfc , Supplying And Erecting 40 Kvar, 440 V 3 Phase, 50 Hz., Contactor Logic & Intelligent Relay Micro Apfc Passive Filter Panel, Consisting Of Suitable Steps Of App/Mpp Type Capacitor Units With Detuned (Harmonic Filter) Reactors Of Suitable Rating , Apfc Panel Shall Be Compliance To Iec 61439 And Power Quality Iec 61921 Standard As Per Specification No Cp-Ed/Apfc , Supplying And Erecting 3M Hdmi Cord Low Voltage Grade Minimum 4K Compliant To Be Laid In Provided Conduits With Male/Female 19 Pin Hdmi Connectors Complete. , Supplying And Erecting 30 Kvar, 440 V 3 Phase, 50 Hz., Contactor Logic & Intelligent Relay Micro Apfc Passive Filter Panel, Consisting Of Suitable Steps Of App/Mpp Type Capacitor Units With Detuned (Harmonic Filter) Reactors Of Suitable Rating , Apfc Panel Shall Be Compliance To Iec 61439 And Power Quality Iec 61921 Standard As Per Specification No Cp-Ed/Apfc , Supplying And Erecting 3 Phase 4 Core 50 Sq.Mm. (3X50+1X35) Aerial Bunched Aluminium Cable Along With Necessary Accessories For Lt Distribution On Provided Lt Pole As Per Specification No. Oh-Cbl/Abc , Supplying And Erecting 3 Phase 4 Core 35 Sq.Mm. (3X35+1X25) Aerial Bunched Aluminium Cable Along With Necessary Accessories For Lt Distribution On Provided Lt Pole As Per Specification No. Oh-Cbl/Abc , Supplying And Erecting 3 Phase 4 Core 25 Sq.Mm. (3X25+1X25) Aerial Bunched Aluminium Cable Along With Necessary Accessories For Lt Distribution On Provided Lt Pole As Per Specification No. Oh-Cbl/Abc , Supplying And Erecting 3 Phase 4 Core 16 Sq.Mm. (3X16+1X25) Aerial Bunched Aluminium Cable Along With Necessary Accessories For Lt Distribution On Provided Lt Pole As Per Specification No. Oh-Cbl/Abc , Supplying And Erecting 20M Hdmi Cord Low Voltage Grade Minimum 4K Compliant To Be Laid In Provided Conduits With Male/Female 19 Pin Hdmi Connectors Complete. , Supplying And Erecting 16 M (Clear Height) Motorized High-Mast (Top-150Mm, Bottom-410 Mm) Hot Dipped Galvanized Material With Average Minimum Thickness 65 Micron, Made From High Tensile Structure Grade Steel As Per Bsen -10025 S 355/E350 & 3 Mm Thickness, With Base Plate 25 Mm Thick X Od 570 Mm Grade As Per Is-2062, Pole Made In Single Section & Submerge Arc Welded, With Lowering & Raising Motorized Unit, Wire Rope Stainless Steel 316 Grade 2 Nos., 7X19 Construction 6 Mm, Sg-Dg U Clamps, Double Drum Winch Assembly 350 Kg, 5X2.5 Sq.Mm Flexible Copper Cable With Lantern Carriage Assembly Suitable For Max. 16 Nos. Luminaires And Its Control Gear Box, Lightning Arrestor, Arrangement For Fixing Aviation Light, High-Mast With Serial Number, Factory Inspection Report/Test Report Of High-Mast Should Be Provided As Per Specifications On Provided Foundation J Type Stud/Bolts With Necessary Accessories Complete. Specification No. OhPl/Hm (Excluding Luminaries) , Supplying And Erecting 16 M (Clear Height) Motorized High-Mast (Top-150Mm, Bottom- 360Mm) Hot Dipped Galvanized Material With Average Minimum Thickness 65 Micron, Made From High Tensile Structure Grade Steel As Per Bsen -10025 S 355/E350 & 3 Mm Thickness, With Base Plate 25 Mm Thick X Od 520 Mm Grade As Per Is-2062, Pole Made In Single Section & Submerge Arc Welded, With Lowering & Raising Motorized Unit, Wire Rope Stainless Steel 316 Grade 2 Nos., 7X19 Construction 5Mm, Sg-Dg U Clamps, Double Drum Winch Assembly 350 Kg, 5X2.5 Sq.Mm Flexible Copper Cable With Lantern Carriage Assembly Suitable For Max. 12 Nos. Luminaires And Its Control Gear Box, Lightning Arrestor, Arrangement For Fixing Aviation Light, High-Mast With Serial Number, Factory Inspection Report/Test Report Of High-Mast Should Be Provided As Per Specifications On Provided Foundation J Type Stud/Bolts With Necessary Accessories Complete. Specification No. OhPl/Hm (Excluding Luminaries , Supplying And Erecting 12V/80Ah To 88Ah Tubular Battery With Battery Terminal Wire, Duly Charged With 36 Months Warranty Complete , Supplying And Erecting 12V/7Ah -7.5Ah Smf Battery With Battery Terminal Wire, Duly Charged With 12 Months Warranty Complete , Supplying And Erecting 12V/42Ah Smf Battery With Battery Terminal Wire, Duly Charged With 24 Months Warranty Complete , Supplying And Erecting 12V/26Ah Smf Battery With Battery Terminal Wire, Duly Charged With 24 Months Warranty Complete , Supplying And Erecting 12V/200Ah Tubular Battery With Battery Terminal Wire, Duly Charged With 36 Months Warranty Complete , Supplying And Erecting 12V/180Ah Tubular Battery With Battery Terminal Wire, Duly Charged With 36 Months Warranty Complete , Supplying And Erecting 12V/17Ah -18Ah Smf Battery With Battery Terminal Wire, Duly Charged With 12 Months Warranty Complete , Supplying And Erecting 12V/150Ah Tubular Battery With Battery Terminal Wire, Duly Charged With 36 Months Warranty Complete. , Supplying And Erecting 12V/130Ah To 135Ah Tubular Battery With Battery Terminal Wire, Duly Charged With 36 Months Warranty Complete. , Supplying And Erecting 12V/100Ah Tubular Battery With Battery Terminal Wire, Duly Charged With 36 Months Warranty Complete. , Supplying And Erecting 12V/100Ah Smf Battery With Battery Terminal Wire, Duly Charged With 24 Months Warranty Complete. , Supplying And Erecting 12.5 M (Clear Height) Motorized High-Mast (Top -150Mm, Bottom- 360Mm) Hot Dipped Galvanized Material With Average Minimum Thickness 65 Micron, Made From High Tensile Structure Grade Steel As Per Bsen - 10025 S 355/E350 & 3Mm Thickness, With Base Plate 25 Mm Thick X Od 520 Mm Grade As Per Is-2062, Pole Made In Single Section & Submerge Arc Welded, With Lowering & Raising Motorized Unit, Wire Rope Stainless Steel 316 Grade 2 Nos., 7X19 Construction 5Mm, Sg-Dg U Clamps, Double Drum With Assembly 250 Kg, 5X2.5 Sq.Mm. Flexible Copper Cable With Lantern Carriage Assembly Suitable For Max. 12 Nos. Luminaires And Its Control Gear Box, Lightning Arrestor, Arrangement For Fixing Aviation Light, High-Mast With Serial Number, Factory Inspection Report/Test Report Of High-Mast Should Be Provided As Per Specifications On Provided Foundation J Type Stud/Bolts With Necessary Accessories Complete As Per Specification No. OhPl/Hm (Excluding Luminaries , Supplying And Erecting 12 V/65Ah Smf Battery With Battery Terminal Wire, Duly Charged Complete With 24 Months Warranty Complete , Supplying And Erecting 11 Kv Outdoor Type Gang Operated Air Break, Triple Pole Switch 200 A Capacity With 3 Post Pin Type Insulator Per Phase, Mounted In Horizontal Or Vertical Position With Necessary Channels On Provided Cross Arm With Adequate Length Of C Class G.L. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground Level With Necessary Clamp. , Supplying And Erecting 10M Hdmi Cord Low Voltage Grade Minimum 4K Compliant To Be Laid In Provided Conduits With Male/Female 19 Pin Hdmi Connectors Complete. , Supplying And Erecting 100 Kvar, 440 V 3 Phase, 50 Hz., Contactor Logic & Intelligent Relay Micro Apfc Passive Filter Panel, Consisting Of Suitable Steps Of App/Mpp Type Capacitor Units With Detuned (Harmonic Filter) Reactors Of Suitable Rating , Apfc Panel Shall Be Compliance To Iec 61439 And Power Quality Iec 61921 Standard As Per Specification No Cp-Ed/Apfc , Supplying And Erecting ‘D’ Type Pole Clamps, Fabricated From 50X6mm Ms Flat With 15Mm Bolts And Nuts Fixed To Steel Tubular Pole Duly Painted With One Coat Of Red Oxide And Two Coats Of Aluminium Paint Complete. , Supplying And Drawing Of 2X1.5 Sq.Mm. Frlsh Grade Copper Wires With 1.5 Sq.Mm Earth Wire In Provided Concealed Pipes For Concealed Type Light/Bell Point Wiring And Terminating On Modular Accessories In Box For Point Wiring For Light/Fan/Bell As Per Specification No: Wg-Pw/Cw , Supplying And Drawing Of 2X1.5 Sq.Mm. Frlsh Grade Copper Wires With 1.5 Sq.Mm Earth Wire In Provided Concealed Pipes For Concealed Type Fan Point Wiring And Terminating On Modular Accessories In Box As Per Specification No: Wg-Pw/Cw , Supplying And Drawing Of 2X1.5 Sq.Mm. Frlsh Grade Copper Wires With 1.5 Sq.Mm Earth Wire In Provided Concealed Pipes And Terminating On Modular Accessories In Box For Point Wiring For Independent Plug As Per Specification No Wg-Pw/Sw , Supplying 230/250V, 50Hz, Evaporative Air Cooler (Desert Cooler) Having Normal Cooling Capacity Of 80Cu.M Per Minute, With 12 Exhaust, Min 75 To 80 Litres Water Capacity Tank With Galvanised Steel Sheet With Grade 350 Minimum, Leak Or Drip Free, Front Grill Shall Be Made Of Non-Corrosive Material, Circular Opening Shall Be More Than Fan Sweep But Not Exceeding More Than 25Mm, Filter Pads Shall Be Made Of Wood Wool Or Any Other Substitute Placed In Non-Corrosive Wire Mesh And Tightened At Places With Side Panels, Noise Level Should Not Be More Than 65Dba At 1M Distance, 3 Core Copper Cable Minimum 2M Length & Metal Casing Of The Electrical Components, Metal Frame Or Chassis Of Cooler Cabinet And All Exposed Metallic Parts, Shall Be Provided With Proper Earthling Complete As Per Specification No. Ap-Wcr/Dac , Supplying 230/250V, 50Hz, Evaporative Air Cooler (Desert Cooler) Having Normal Cooling Capacity Of 60 To 70 Cu.M Per Minute, With 12 Exhaust, Min 68 Litres Water Capacity Tank With Galvanised Steel Sheet With Grade 350 Minimum, Leak Or Drip Free, Front Grill Shall Be Made Of Non-Corrosive Material, Circular Opening Shall Be More Than Fan Sweep But Not Exceeding More Than 25Mm, Filter Pads Shall Be Made Of Wood Wool Or Any Other Substitute Placed In Non-Corrosive Wire Mesh And Tightened At Places With Side Panels, Noise Level Should Not Be More Than 65Dba At 1M Distance, 3 Core Copper Cable Minimum 2M Length & Metal Casing Of The Electrical Components, Metal Frame Or Chassis Of Cooler Cabinet And All Exposed Metallic Parts, Shall Be Provided With Proper Earthling Complete As Per Specification No. Ap-Wcr/Dac , Supplying , Erecting & Terminating Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 11 Kv(Ue), 3 X 95 Sq. Mm. Aluminium Conductor Laid In Provided Trench / Pipe As Per Specification No. Cb-Ht , Supplying , Erecting & Terminating Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 11 Kv(Ue), 3 X 120 Sq. Mm. Aluminium Conductor Laid In Provided Trench / Pipe As Per Specification No. Cb-Ht , Supplying , Erecting & Terminating Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 11 Kv(E), 3 X 95 Sq. Mm. Aluminium Conductor Laid In Provided Trench / Pipe As Per Specification No. Cb-Ht , Supplying , Erecting & Terminating 11 Kv(E), 3 X 70 Sq. Mm., Aluminium Conductor Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable Laid In Provided Trench / Pipe As Per Specification No. Cb-Ht , Supplying & Laying (Including Excavation) Reinforced Cement Concrete Pipe Of Is 458:2003 Np-2 Class Of 250 Mm Internal Diameter In Proper Line, Level And Slope Including Providing And Fixing Collars In Cement Mortar 1:2 And Curing Etc. Complete. , Supplying & Laying (Including Excavation) Reinforced Cement Concrete Pipe Of Is 458:2003 Np-2 Class Of 150 Mm Internal Diameter In Proper Line, Level And Slope Including Providing And Fixing Collars In Cement Mortar 1:2 And Curing Etc. Complete. , Supplying & Laying (Including Excavation) Half Round Reinforced Cement Concrete Pipe Of Is 458:2003 Np-2 Class Of 250 Mm Internal Diameter In Proper Line, Level And Slope Including Providing And Fixing Collars In Cement Mortar 1:2 And Curing Etc. Complete , Supplying & Laying (Including Excavation) Half Round Reinforced Cement Concrete Pipe Of Is 458:2003 Np-2 Class Of 150 Mm Internal Diameter In Proper Line, Level And Slope Including Providing And Fixing Collars In Cement Mortar 1:2 And Curing Etc. Complete , Supplying & Erecting Water Tight Terminal Box Of Cast Iron Of Size 300 X 200 X 150 Mm Complete On Pole As Per Specification No. Cb-Sb , Supplying & Erecting Water Tight Terminal Box Of 1.6 Mm (16 Gauge) Crca Sheet Of Size 300 X 200 X 150 Mm Complete On Pole As Per Specification No. Cb , Supplying & Erecting Water Tight Terminal Box Of 1.6 Mm (16 Gauge) Crca Sheet Of Size 150 X 100 X 100 Mm Complete On Pole As Per Specification No. Cb , Supplying & Erecting Triple Pole And Neutral Distribution Board (Tpndb), Spmcb Of 8 Ways / Phase (24 Poles), With Door, 1.2Mm Thickness Surface/ Flush Mounted, Ip 43 Protection On Iron/Gi Frame (Horizontal Busbar Type) As Per Specification No. Sw-Swr/Mcbdb , Supplying & Erecting Triple Pole And Neutral Distribution Board (Tpndb), Spmcb Of 4 Ways/Phase (12 Poles), With Door, 1.2Mm Thickness, Surface/Flush Mounted, Ip 43 Protection On Iron/Gi Frame (Horizontal Busbar Type) As Per Specification No. Sw-Swr/Mcbdb , Supplying & Erecting Triple Pole And Neutral Distribution Board (Tpndb), Spmcb Of 12 Ways /Phase (36 Poles), With Door, 1.2Mm Thickness Surface/Flush Mounted, Ip 43 Protection On Iron/Gi Frame (Horizontal Busbar Type) As Per Specification No. Sw-Swr/Mcbdb , Supplying & Erecting Triple Pole And Neutral Distribution Board (Tpndb), Sp/Tp Mcbs Total 8 Ways /24 Poles, With Door, 1.2Mm Thickness Surface/Flush Mounted, Ip 43 Protection On Iron/Gi Frame (Vertical Busbar Type) As Per Specification No. Sw-Swr/Mcbdb , Supplying & Erecting Triple Pole And Neutral Distribution Board (Tpndb), Sp/Tp Mcbs Total 4 Ways /12 Poles, With Door, 1.2Mm Thickness Surface/Flush Mounted, Ip 43 Protection On Iron/Gi Frame (Vertical Busbar Type) As Per Specification No. Sw-Swr/Mcbdb , Supplying & Erecting Triple Pole And Neutral Distribution Board (Tpndb), Sp/Tp Mcbs Total 12 Ways /36 Poles, With Door, 1.2Mm Thickness Surface/Flush Mounted, Ip 43 Protection On Iron/Gi Frame (Vertical Busbar Type) As Per Specification No. Sw-Swr/Mcbdb , Supplying & Erecting Triple Pole And Neutral Distribution Board (Tpndb), 3 Pole/4 Pole Mccb As Incomer & Outgoing Sp Mcb (36 Poles) Or Tp Mcb Of 12 Ways (36 Poles), With Door, 1.2Mm Thickness, Surface/Flush Mounted, On Iron/Gi Frame (Vertical Busbar Type) As Per Specification No. Sw-Swr/Mcbdb1 , Supplying & Erecting Three Phase, 415V, Street Light Control Panel Up To The Max Load Of 6Kw, Tpn Mcb 40A, Powder Coated Crca 14 Swg Sheet, Outdoor Type, Having Ip54,Ik10 Protection, Suitable Rating Contactor, 24 Hrs. Astronomical Time Switch With Minimum 5 Years Battery Back Up, Auto/Manual Selector Switch, On/Off Push Buttons, Indicator Lamps, Control Wiring, Metering Device, Etc. For Automatic Operation, With Overcurrent, Short Circuit, Earth Fault Protection On Provided Iron Frame / Cc Foundation. , Supplying & Erecting Three Phase, 415V, Street Light Control Panel Up To The Max Load Of 12Kw, Tpn Mcb 63A, Powder Coated Crca 14 Swg Sheet, Outdoor Type, Having Ip54,Ik10 Protection, Suitable Rating Contactor, 24 Hrs. Astronomical Time Switch With Minimum 5 Years Battery Back Up, Auto/Manual Selector Switch, On/Off Push Buttons, Indicator Lamps, Control Wiring, Metering Device, Etc. For Automatic Operation, With Overcurrent, Short Circuit, Earth Fault Protection On Provided Iron Frame / Cc Foundation. , Supplying & Erecting Street Light Control Panel Outdoor Type, For Three Phase 4 Wire System Having In Built Astronomical Adjustable Programmable Timer With Minimum 5 Years Battery Back Up, Having Ip54,Ik10 Protection, 4 Pole Contactor Up To 60A, With Maintenance Mode To Switch On Street Lights During Time Of Repairs With Energy Consumption Data Recording For Analysis And Lcd Display For Energy Monitoring With Numeric Key Pad In Provided Box. , Supplying & Erecting Street Light Control Panel Outdoor Type, For Single Phase 2 Wire System Having In Built Astronomical Adjustable Programmable Timer With Minimum 5 Years Battery Back Up, Having Ip54,Ik10 Protection, 2 Pole Contactor Up To 60 A, With Maintenance Mode To Switch On Street Lights During Time Of Repairs With Energy Consumption Data Recording For Analysis And Lcd Display For Energy Monitoring With Numeric Key Pad In Provided Box. , Supplying & Erecting Single Pole Cut Point Channel Set Of For 11Kv Ht Oh Line Two Channel Of Size 100X50x6mm 1.6M Long Having Stud Angle Of Size 50X50x6mm 1.5M Long With Necessary Clamps, Nut Bolts Etc. Complete As Per Drawing. , Supplying & Erecting Single Phase, 240V, Street Light Control Panel Up To The Max Load Of 6Kw, Spn Mcb 40A, Powder Coated Crca 14 Swg Sheet, Outdoor Type, Having Ip54,Ik10 Protection, Suitable Rating Contactor, 24 Hrs. Astronomical Time Switch With Minimum 5 Years Battery Back Up, Auto/Manual Selector Switch, On/Off Push Buttons, Indicator Lamps, Control Wiring, Metering Device, Etc. For Automatic Operation, With Overcurrent, Short Circuit, Earth Fault Protection On Provided Iron Frame/ Cc Foundation. , Supplying & Erecting Single Phase, 240V, Street Light Control Panel Up To The Max Load Of 12Kw, Spn Mcb 63A, Powder Coated Crca 14 Swg Sheet, Outdoor Type, Having Ip54,Ik10 Protection, Suitable Rating Contactor, 24 Hrs. Astronomical Time Switch With Minimum 5 Years Battery Back Up, Auto/Manual Selector Switch, On/Off Push Buttons, Indicator Lamps, Control Wiring, Metering Device, Etc. For Automatic Operation & Overcurrent, Short Circuit, Earth Fault Protection On Provided Iron Frame / Cc Foundation. , Supplying & Erecting Single Compression Type Brass Cable Glands For 4 Core 35 Sq.Mm./3 Core 50 Sq.Mm. For Xlpe Armoured Cable As Per Specification No. Cb-Gl , Supplying & Erecting Single Compression Type Brass Cable Glands For 3½ Core 95 Sq Mm For Xlpe Armoured Cable As Per Specification No. Cb-Gl , Supplying & Erecting Single Compression Type Brass Cable Glands For 3½ Core 70 Sq Mm For Xlpe Armoured Cable As Per Specification No. Cb-Gl , Supplying & Erecting Single Compression Type Brass Cable Glands For 3 To 4 Core 6 Sq Mm /2 To 4 Core 10 Sq Mm For Xlpe Armoured Cable As Per Specification No. Cb-Gl , Supplying & Erecting Single Compression Type Brass Cable Glands For 3 To 4 Core 16 Sq Mm /3 To 4 Core 25 Sq Mm /3 Core 35 Sq Mm For Xlpe Armoured Cable As Per Specification No. Cb-Gl , Supplying & Erecting Single Compression Type Brass Cable Glands For 2 To 4 Core 2.5 Sq Mm /2 To 4 Core 4 Sq Mm /2 Core 6 Sq Mm For Xlpe Armoured Cable As Per Specification No. Cb-Gl , Supplying & Erecting Ready To Use Retrofit T8 Led 18 / 20 Tube Light With Polycarbonate Body, Heat Sink, Integrated Hf Electronic Driver Complete & Compatible To T8 / T12 Led Luminaire By Disconnecting Starter & Ballast If Necessary. , Supplying & Erecting Ms Pole Bracket For Lt Oh Conductor Fabricated From 65X65x6 Mm Section, 550Mm Long For Necessary Nos. Of Provided Insulators And Erecting O , Supplying & Erecting Ms Pole Bracket For Guarding/Lt Oh Line, Fabricated From Ism Channel 75X40x6mm And 550Mm Long For Necessary Nos. Of Provided Insulators And Erecting On Pole With 50X6mm Clamp Complete As Per Specification No. Oh-Pl/Bkt , Supplying & Erecting Ms Pole Bracket For Guarding/Lt Oh Line, Fabricated From Ism Channel 75X40x6mm And 1100Mm Long For Necessary Nos. Of Provided Insulators And Erecting On Pole With 50X6mm Clamp Complete As Per Specification No. Oh-Pl/Bkt , Supplying & Erecting Ms Pole Bracket For Guarding/Lt Oh Line, Fabricated From Angle Iron 50X50x6mm And 550Mm Long For Necessary Nos. Of Provided Insulators, And Erecting On Pole With 50X6mm Clamp Complete As Per Specification No. Oh-Pl/Bkt , Supplying & Erecting Ms Pole Bracket For Guarding/Lt Oh Line, Fabricated From Angle Iron 50X50x6mm And 1100Mm Long For Necessary Nos. Of Provided Insulators, And Erecting On Pole With 50X6mm Clamp Complete As Per Specification No. Oh-Pl/Bkt , Supplying & Erecting Minimum Three & Above Star Rated Centrifugal Water Pump (Monoblock), 415V, Three Phase 50 Cycles A.C. Supply Of 2.25 Kw/3 Hp With Discharge 600/110 Litres Per Minute (Lpm) For Head Of 13/43 M And 65 Mm Suction/ 50 Mm Delivery Pipe On Provided C.C. Foundation As Per Specification No. Wp-Cgp , Supplying & Erecting Minimum Three & Above Star Rated Centrifugal Water Pump (Monoblock), 415V, Three Phase 50 Cycles A.C. Supply Of 1.5 Kw/2 Hp With Discharge 600/140 Litres Per Minute (Lpm) For Head Of 8/22 M And 50 Mm Suction/ 40 Mm Delivery Pipe On Provided C.C. Foundation As Per Specification No. Wp-Cgp , Supplying & Erecting Minimum Three & Above Star Rated Centrifugal Water Pump (Monoblock), 415 V, Three Phase 50 Cycles A.C. Supply Of 5.625 Kw/7.5 Hp With Discharge Of 780/170 Litres Per Minute (Lpm) For Head Of 33/54 M And 80Mm Suction/ 65Mm Delivery Pipe Of Size, On Provided C.C. Foundation As Per Specification No. Wp-Cgp , Supplying & Erecting Minimum Three & Above Star Rated Centrifugal Water Pump (Monoblock), 415 V, Three Phase 50 Cycles A.C. Supply Of 3.75 Kw/5 Hp With Discharge 715/200 Litres Per Minute (Lpm) For Head Of 17/39 M And 65 Mm Suction/ 50 Mm Delivery Pipe On Provided C.C. Foundation As Per Specification No. Wp-Cgp , Supplying & Erecting Minimum Three & Above Star Rated Centrifugal Water Pump (Monoblock), 230V, Single Phase 50 Cycles A.C. Supply Of 1.125 Kw/1.5Hp With Discharge 198/50 Litres Per Minute (Lpm)) For Head Of 15/37.5 M & 40 Mm Suction/ 32 Mm Delivery Pipe On Provided C.C. Foundation As Per Specification No. Wp-Cgp , Supplying & Erecting Integral Post Top Lantern Fixtures (Mushroom Type) Suitable For Led Lamp Upto 12 W Consisting Of Clear Acrylic Top Cover, Cast Aluminium Pole Cap Complete With Accessories On Provided Pole /Bracket As Per Specification No. Fg-Odf/Ptl , Supplying & Erecting Integral Post Top Lantern Fixtures (Light House Type) Suitable Upto Led 18 W Lamp Consisting Of Combination Of Spun Aluminium Canopy & Clear Acrylic Top Cover, Cast Aluminium Pole Cap On Provided Pole/ Bracket As Per Specification No. Fg-Odf/Ptl , Supplying & Erecting Integral Post Top Lantern Fixtures (Globe Type) Suitable For Led Lamp Upto 12 W Consisting Of Aesthetic Round Clear Acrylic Top Cover, Cast Aluminium Pole Cap On Provided Pole /Bracket As Per Specification No. Fg , Supplying & Erecting Inline D.P. Structure For 11/0.415Kv, 63Kva Transformer With Rsj Pole 2 Nos. Of Size 100X116mm X 11M Long With Suitable Distribution Box Of Crca Sheet 16 Swg With 4 Pole Mccb 100A As Incomer & 6 Nos. 63A Kitkat/Mccb For Outing Circuits. Transformer D.P. Structure Includes The A.B. Switch 200A, D.O. Fuse Set & L.A. Set. 2 Nos. Top Channel Of Size 100X50mm For Erection Of A.B. Switch & 2 Nos. Base Channel Of Size 100X50mm For Erecting Transformer Channel Of Size 75X40mm For Erecting D.O. Fuse Set, L.A., A.B. Switch Handle Etc. Angle Of Size 50X50x6mm For Erecting Distribution Box, Transformer Belt Etc. As Per Drawing (Min. 124 Kg. Iron Work ) With Necessary Clamps, Nut-Bolts. V Cross Arm, Top Clip, Insulators Etc. With Caution Board & Barbed Wire, D.P. Structure Shall Be Erected In C.C. Foundation Complete. , Supplying & Erecting Inline D. P. Structure For 11/0.415 Kv, 200 Kva Transformer With R.S.J. Pole 2 Nos. Of Size 100 X 116 Mm X 11 Mtr. Long With Suitable Distribution Box Of C.R.C.A. Sheet 16 Swg With 4 Pole Mccb 300 Amps As Incomer & 6 Nos. 100 Amps Kitkat / Mccb For Out Going Circuits. Transformer D.P. Structure Includes The A. B. Switch 200 Amps, D.O. Fuse Set & L.A. Set. 2 Nos Of Top Channel Of Size 100 Mmx 50 Mm For Erection Of A.B. Switch & 2 Nos. Base Channel Of Size 100 Mm X 50 Mm For Erecting Transformer Channel Of Size 75 X40 Mm For Erecting D.O. Fuse Set, L.A., A.B. Switch Handle Etc. Angle Of Size 50 X 50 X6 Mm For Erecting Distribution Box , Transformer Belt Etc.As Per Drawing (Min. 124 Kg. Iron Work ) With Necessary Clamps, Nut-Bolts. V Cross Arm, Top Clip, Insulators Etc. Complete With Caution Board & Barbed Wire. D.P. Structure Shall Be Erected In C.C. Foundation Complete. , Supplying & Erecting Inline D. P. Structure For 11/0.415 Kv, 100 Kva Transformer With R.S.J. Pole 2 Nos. Of Size 100 X 116 Mm X 11 Mtr. Long With Suitable Distribution Box Of C.R.C.A. Sheet 16 Swg With 4 Pole Mccb 200 Amps As Incomer & 6 Nos. 100 Amps Kitkat / Mccb For Out Going Circuits. Transformer D.P. Structure Includes The A. B. Switch 200 Amps, D.O. Fuse Set & L.A. Set. 2 Nos. Of Top Channel Of Size 100 Mmx 50 Mm For Erection Of A.B. Switch & 2 Nos. Base Channel Of Size 100 Mm X 50 Mm For Erecting Transformer Channel Of Size 75 X40 Mm For Erecting D.O. Fuse Set, L.A., A.B. Switch Handle Etc. Angle Of Size 50 X 50 X6 Mm For Erecting Distribution Box , Transformer Belt Etc.As Per Drawing (Min. 124 Kg. Iron Work ) With Necessary Clamps, Nut-Bolts. V Cross Arm, Top Clip, Insulators Etc. Complete With Caution Board & Barbed Wire, D.P. Structure Shall Be Erected In C.C. Foundation Complete , Supplying & Erecting G.I. Pipe ‘A’ Class 75 Mm Dia. Erected For Enclosing Xlpe Armoured Cable On Wall/Pole As Per Specification No. Cb-Ce , Supplying & Erecting G.I. Pipe ‘A’ Class 50 Mm Dia. Erected For Enclosing Xlpe Armoured Cable On Wall/Pole As Per Specification No. Cb-Ce , Supplying & Erecting G.I. Pipe ‘A’ Class 40 Mm Dia. Erected For Enclosing Xlpe Armoured Cable On Wall/Pole As Per Specification No. Cb-Ce , Supplying & Erecting G.I. Pipe ‘A’ Class 25 Mm Dia. Erected For Enclosing Xlpe Armoured Cable On Wall/Pole As Per Specification No. Cb-Ce , Supplying & Erecting Fully Automatic Star/Delta Starter Suitable For 12.5 H.P To 15 H.P. For 3 Phase Squirrel Cage Motor Totally Enclosed With Overload And No Volt Relay Complete Erected On Provided Angle Iron Frame. , Supplying & Erecting Frp Box Of Size 300Mm X 200Mm X 125 Mm, 2.7 Mm Thick Complete On Pole/Wall As Per Specification No. Cb-Sb , Supplying & Erecting Frp Box Of Size 250Mm X 200Mm X 100 Mm, 2.7 Mm Thick Complete On Pole/Wall As Per Specification No. Cb-Sb , Supplying & Erecting Frp Box Of Size 150Mm X 125Mm X 100 Mm, 2.7 Mm Thick Complete On Pole/Wall As Per Specification No. Cb-Sb , Supplying & Erecting Four Pole On Load Change Over Switch, 415V, 63A, Open Execution Having Staggered Termination, Phase Barrier, Shroud Termination And Terminal Cover Along With Auxiliary Contacts And Ready To Upgrade With Fuse Protection Kit, Rotary Handle, Operational Current Category Ac23a Complying To Is/Iec 60947-3 Part-1/3. , Supplying & Erecting Four Pole On Load Change Over Switch, 415V, 40A, Open Execution Having Staggered Termination, Phase Barrier, Shroud Termination And Terminal Cover Along With Auxiliary Contacts And Ready To Upgrade With Fuse Protection Kit, Rotary Handle,Operational Current Category Ac23a Complying To Is/Iec 60947-3 Part-1/3. , Supplying & Erecting Four Pole On Load Change Over Switch, 415V, 32A, Open Execution Having Staggered Termination, Phase Barrier, Shroud Termination And Terminal Cover Along With Auxiliary Contacts And Ready To Upgrade With Fuse Protection Kit, Rotary Handle, Operational Current Category Ac23a Complying To Is/Iec 60947-3 Part-1/3 . , Supplying & Erecting Four Pole On Load Change Over Switch, 415V, 315- 320A, Open Execution Having Staggered Termination, Phase Barrier, Shroud Termination And Terminal Cover Along With Auxiliary Contacts And Ready To Upgrade With Fuse Protection Kit, Operational Current Category Ac23a Complying To Is/Iec 60947-3 Part-1/3. , Supplying & Erecting Four Pole On Load Change Over Switch, 415V, 200A, Open Execution Having Staggered Termination, Phase Barrier, Shroud Termination And Terminal Cover Along With Auxiliary Contacts And Ready To Upgrade With Fuse Protection Kit, Operational Current Category Ac23a Complying To Is/Iec 60947-3 Part-1/3. , Supplying & Erecting Four Pole On Load Change Over Switch, 415V, 160A, Open Execution Having Staggered Termination, Phase Barrier, Shroud Termination And Terminal Cover Along With Auxiliary Contacts And Ready To Upgrade With Fuse Protection Kit, Rotary Handle, Operational Current Category Ac23a Complying To Is/Iec 60947-3 Part-1/3. , Supplying & Erecting Four Pole On Load Change Over Switch, 415V, 100A, Open Execution Having Staggered Termination, Phase Barrier, Shroud Termination And Terminal Cover Along With Auxiliary Contacts And Ready To Upgrade With Fuse Protection Kit, Rotary Handle, Operational Current Category Ac23a Complying To Is/Iec 60947-3 Part-1/3. , Supplying & Erecting Flat Flexible 3 Core 6 Sq.Mm Pvc Sheathed Submersible Type Copper Cable Suitably Clamped At Fixed Intervals With Column Pipe Assembly Complete. , Supplying & Erecting Flat Flexible 3 Core 4 Sq.Mm Pvc Sheathed Submersible Type Copper Cable Suitably Clamped At Fixed Intervals With Column Pipe Assembly Complete. , Supplying & Erecting Flat Flexible 3 Core 2.5 Sq.Mm Pvc Sheathed Submersible Type Copper Cable Suitably Clamped At Fixed Intervals With Column Pipe Assembly Complete. , Supplying & Erecting Flat Flexible 3 Core 10 Sq.Mm Pvc Sheathed Submersible Type Copper Cable Suitably Clamped At Fixed Intervals With Column Pipe Assembly Complete. , Supplying & Erecting D.O.L Starter Suitable For 415 V, 3 Phase 50 Cycles With No Volt Coil And Overload Element With Necessary Materials And Connected To Supply Up To 7.5 H.P. , Supplying & Erecting D.O.L Starter Suitable For 415 V, 3 Phase 50 Cycles With No Volt Coil And Overload Element With Necessary Materials And Connected To Supply For 10 H.P. , Supplying & Erecting D.O.L Starter Suitable For 250 V, Single Phase 50 Cycles With Overload Element With Necessary Materials And Connected To Supply Up To 3 H.P. , Supplying & Erecting Crimping Type Copper Lugs For Cable Up To 16 Sq Mm Complete As Per Specification No. Cb-Cl/Cu , Supplying & Erecting Crimping Type Copper Lugs For Cable 70 Sq Mm Complete As Per Specification No. Cb-Cl/Cu , Supplying & Erecting Crimping Type Copper Lugs For Cable 35 Sq Mm Complete As Per Specification No. Cb-Cl/Cu , Supplying & Erecting Crimping Type Copper Lugs For Cable 25 Sq Mm Complete As Per Specification No. Cb-Cl/Cu , Supplying & Erecting Crimping Type Aluminium Lugs For Cable Up To 16 Sq Mm Complete As Per Specification No. Cb-Cl/Al , Supplying & Erecting Crimping Type Aluminium Lugs For Cable 95 Sq Mm Complete As Per Specification No. Cb-Cl/Al , Supplying & Erecting Crimping Type Aluminium Lugs For Cable 70 Sq Mm Complete As Per Specification No. Cb-Cl/Al , Supplying & Erecting Crimping Type Aluminium Lugs For Cable 50 Sq Mm Complete As Per Specification No. Cb-Cl/Al , Supplying & Erecting Crimping Type Aluminium Lugs For Cable 35 Sq Mm Complete As Per Specification No. Cb-Cl/Al , Supplying & Erecting Crimping Type Aluminium Lugs For Cable 25 Sq Mm Complete As Per Specification No. Cb-Cl/Al , Supplying & Erecting Crca Sheet Metal Enclosures Of 1.2Mm Thickness With 30 A, 3 Pin Plug & Earth Socket And 30A, 3 Pin Plug Top With 30A Triple Pole Mcb Having Rated Short - Circuit Breaking Capacity (Icn) 10Ka Complete Erected On Angle Iron / Gi Frame. , Supplying & Erecting Co-Axial Copper Cable Low Voltage Grade Tri-Shielded Rg11 As Per Specification No. Wg-Tw , Supplying & Erecting Co-Axial Copper Cable Low Voltage Grade Tri-Shielded Rg , Supplying & Erecting Cast Iron Cable Indicator Plate Buried Along With Route Of Cable For Pvc / Xlpe Armoured Cable As Per Specification No. Cb-Cip , Supplying & Erecting Automatic Control Panel For 3 Ph, 415 Volt, /Centrifugal Pump Set Up To 10 Hp Consisting Of Star Delta Starter Having Relay Range 9-14 Amp, S.P.P., Combined Ammeter/ Voltmeter, Phase Indicating Lamp Enclosed In Crca Powder Coated Vibration Proof Enclosure With Ip 54 Protection. Control Panel Should Offer Single Phasing, Phase Reversal, Phase Imbalance Etc. , Supplying & Erecting Automatic Control Panel For 3 Ph, 415 Volt, /Centrifugal Pump Set Up To 10 - 15 Hp Consisting Of Star Delta Starter Having Relay Range 13- 22 Amp, S.P.P., Combined Ammeter/ Voltmeter, Phase Indicating Lamp Enclosed In Crca Powder Coated Vibration Proof Enclosure With Ip 54 Protection. Control Panel Should Offer Single Phasing, Phase Reversal, Phase Imbalance Etc. , Supplying & Erecting 50 Pair Telephone Copper Cable 0.5 Mm Dia. With High Density Polyethylene Insulation, Polyester Taped, Nylon Rip Cord & Grey Colour Sheathed With Fr Pvc, Conforming To Itd Specification S/Ws 113C Laid In Provided Pvc Casing Capping/Conduit As Per Specification No. Wg-Tw , Supplying & Erecting 5 Pair Telephone Copper Cable 0.5 Mm Dia. With High Density Polyethylene Insulation, Polyester Taped, Nylon Rip Cord & Grey Colour Sheathed With Fr Pvc, Conforming To Itd Specification S/Ws 113C Laid In Provided Pvc Casing Capping/Conduit As Per Specification No. Wg-Tw , Supplying & Erecting 4 Pair Telephone Copper Cable 0.5 Mm Dia. With High Density Polyethylene Insulation, Polyester Taped, Nylon Rip Cord & Grey Colour Sheathed With Fr Pvc, Conforming To Itd Specification S/Ws 113C Laid In Provided Pvc Casing Capping/Conduit As Per Specification No. Wg-Tw , Supplying & Erecting 3 Pair Telephone Copper Cable 0.5 Mm Dia. With High Density Polyethylene Insulation, Polyester Taped, Nylon Rip Cord & Grey Colour Sheathed With Fr Pvc, Conforming To Itd Specification S/Ws 113C Laid In Provided Pvc Casing Capping/Conduit As Per Specification No. Wg-Tw , Supplying & Erecting 20 Pair, 0.5Mm Dia, Jelly Filled Unarmoured Telephone Copper Cable With Poly-Al Laminate Moisture Barrier, Laid In Provided Pvc Casing Capping/Conduit As Per Specification No. Wg-Tw , Supplying & Erecting 20 Pair Telephone Copper Cable 0.5 Mm Dia. With High Density Polyethylene Insulation, Polyester Taped, Nylon Rip Cord & Grey Colour Sheathed With Fr Pvc, Conforming To Itd Specification S/Ws 113C Laid In Provided Pvc Casing Capping/Conduit As Per Specification No. Wg-Tw , Supplying & Erecting 2 Pair Telephone Copper Cable 0.5 Mm Dia. With High Density Polyethylene Insulation, Polyester Taped, Nylon Rip Cord & Grey Colour Sheathed With Fr Pvc, Conforming To Itd Specification S/Ws 113C Laid In Provided Pvc Casing Capping/Conduit As Per Specification No. Wg-Tw , Supplying & Erecting 18W, 230V Integral Type Led Lamp Suitable For B-22 / E , Supplying & Erecting 14W, 230V Integral Type Led Lamp Suitable For B-22 / E27 Base. , Supplying & Erecting 10-12W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. , Supplying & Erecting 100 Pair Telephone Copper Cable 0.5 Mm Dia. With High Density Polyethylene Insulation, Polyester Taped, Nylon Rip Cord & Grey Colour Sheathed With Fr Pvc, Conforming To Itd Specification S/Ws 113C Laid In Provided Pvc Casing Capping/Conduit As Per Specification No. Wg-Tw , Supplying & Erecting 10 Pair, 0.5Mm Dia, Jelly Filled Unarmoured Telephone Copper Cable With Poly-Al Laminate Moisture Barrier, Laid In Provided Pvc Casing Capping/Conduit As Per Specification No. Wg-Tw , Supplying & Erecting 10 Pair Telephone Copper Cable 0.5 Mm Dia. With High Density Polyethylene Insulation, Polyester Taped, Nylon Rip Cord & Grey Colour Sheathed With Fr Pvc, Conforming To Itd Specification S/Ws 113C Laid In Provided Pvc Casing Capping/Conduit As Per Specification No. Wg-Tw , Supplying & Erecting 0.5 Mm Dia, Copper Jumper Wire As Per Specification No. Wg-Tw , Supplying & Arranging Burnt Cured Bricks Properly For Various Purposes (Size 9”X4.25”X3”) At Work For 100 Bricks Complete. , Supply And Erecting 9M (Clear Height) Fixed Type High-Mast (Top-100Mm, Bottom- 200Mm) With Hexagonal /Round Bracket And Foundation Bolts Suitable For Max. 4 Nos. Flood Light Fixtures On Provided Foundation As Per Specification No. Oh-Pl/Opl (Excluding Luminaires). , Rewinding The Motor Of The Exhaust Fan 900 / 1400 Rpm 300 Mm Of All Types, Makes And Over Hauling Including Minor Repairs, Lubricating Of Ball Bearings & Bush Bearing, And Replacing Condenser, Screws Etc. & Testing For Original Speed And Consumption With Guarantee For One Year , Rewinding The Motor Of The Ceiling Fan 1200 Mm / 1400 Mm Of All Types , Makes And Over Hauling Including Minor Repairs Lubricating Of Ball Bearings & Bush Bearing, And Replacing Condenser, Screws Etc. & Testing For Original Speed And Consumption With Guarantee For One Year. , Rewinding The Motor Of Table / Pedestal / Wall Bracket / Cabin Fans Of All Type And Makes Including Minor Repairs Lubricating Of Ball Bearings & Bush Bearing, And Replacing Condenser, Screws Etc. Testing For Original Speed And Consumption With Guarantee For 1 Year Including Transportation From Site And Back , Rewinding Of Electric Motor Upto 1 H.P. Single Phase Up To 1400 Rpm Of All Types, Makes With Copper Wire, Overhauling With Minor Repairs, Lubricating Of Ball Bearings & Bush Bearing, And Replacing Condenser, Screws Etc. Testing For The Original Speed And No Load Consumption With Guarantee For One Year. , Rewinding Of Electric Motor Up To 1 H.P. Three Phase Up To 1400 Rpm Of All Types And Makes With Copper Wire, Overhauling With Minor Repairs, Lubricating Of Ball Bearings & Bush Bearing, And Replacing Screws Etc. Testing For The Original Speed And No Load Consumption With Guarantee For One Year , Rewinding Of Electric Motor Above 7.5 H.P. Upto 10 H.P. Three Phase Up To 1400 Rpm Of All Types And Makes With Copper Wire, Overhauling With Minor Repairs, Lubricating Of Ball Bearings & Bush Bearing, And Replacing Screws Etc. Testing For The Original Speed And No Load Consumption With Guarantee For One Yea , Rewinding Of Electric Motor Above 5 H.P. Upto 7.5 H.P. Three Phase Up To 1400 Rpm Of All Types And Makes With Copper Wire, Overhauling With Minor Repairs, Lubricating Of Ball Bearings & Bush Bearing, And Replacing Screws Etc. Testing For The Original Speed And No Load Consumption With Guarantee For One Year , Rewinding Of Electric Motor Above 3 H.P.Upto 5 H.P. Three Phase Up To 1400 Rpm Of All Types And Makes With Copper Wire, Overhauling With Minor Repairs, Lubricating Of Ball Bearings & Bush Bearing, And Replacing Screws Etc. Testing For The Original Speed And No Load Consumption With Guarantee For One Year , Rewinding Of Electric Motor Above 2 H.P. Upto 3 H.P. Three Phase Up To 1400 Rpm Of All Types And Makes With Copper Wire, Overhauling With Minor Repairs, Lubricating Of Ball Bearings & Bush Bearing, And Replacing Screws Etc. Testing For The Original Speed And No Load Consumption With Guarantee For One Year , Rewinding Of Electric Motor Above 1 Hp Upto 2 H.P. Three Phase Up To 1400 Rpm Of All Types And Makes With Copper Wire, Overhauling With Minor Repairs, Lubricating Of Ball Bearings & Bush Bearing, And Replacing Screws Etc. Testing For The Original Speed And No Load Consumption With Guarantee For One Year , Providng Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm Complete With All Materials, Testing & Recording The Results As Per Specification No. Ea-Ep , Providing Recess In Brick Wall Suitable For Erection Of Exhaust Fan Up To 450Mm. Sweep Complete With Grouting Of Nut, Bolts, Plastering And Colour Washing To Match The Colour Of The Wall For The Wall Thickness Of 225 Mm. , Providing Recess In Brick Wall Suitable For Erection Of Exhaust Fan Up To 450 Mm Sweep Complete With Grouting Of Nut, Bolts, Plaster In Hand Colour Washing To Match The Colour Of The Wall For The Wall Thickness Of 150 Mm. , Providing Pipe Type Earthing With 40Mm. Dia. G.I. Pipe Or 20 Mm Dia. G.I. Rod Complete With All Materials Testing And Recording The Results As Per Specification No. Ea-Ep , Providing Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm With Funnel With A Wire Mesh For Watering And Brick Masonry Block C.L. Cover Complete With All Materials, Testing & Recording The Results As Per Specification No. Ea-Ep , Providing Earthing With Copper Earth Plate Size 60 X 60 X 0.315 Cm With Funnel With A Wire Mesh For Watering And Brick Masonry Block C.L. Cover With Minimum 25 Kg Carbon Based Environment Friendly Back Fill Ground Enhancing Compound Complete With All Materials, Testing & Recording The Results As Per Specification No Ese -La , Providing Earthing With Copper Earth Plate Size 30 X 30 X 0.315 Cm Complete With All Materials, Testing & Recording The Results As Per Specification No. Ea-Ep , Providing And Fixing Reinforced Cement Concrete Cover Of Size 60 Cm X 45 Cm With Frame Over Inspection Chamber Etc. Complete Of Medium Duty (100 Kilogram). , Providing And Erecting Heat Shrinkable Indoor Termination Kit For 11 Kv ( E ) Xlpe Ht Cable 3X Up To 95 Sq. Mm. With Necessary Material As Per Specification No. Cb-Jt/Ht , Providing And Erecting Galvanised 1000Mm Single Arm Sword Type Bracket With Frp Dome And Ball As Per Specification No. Oh-Pl/Pbkt , Providing And Erecting Galvanised 1000Mm Double Arm Sword Type Bracket With Frp Dome And Ball As Per Specification No. Oh-Pl/Pbkt , Providing & Erecting Hot Dipped Galvanised Ladder Type Cable Tray Manufactured From 16 Swg (1.6 Mm Thick) Gi Sheet Of 400 Mm Width & 100 Mm Height Comprising All Required Standard Accessories. , Providing & Erecting Hot Dipped Galvanised Ladder Type Cable Tray Manufactured From 16 Swg (1.6 Mm Thick) Gi Sheet Of 300 Mm Width & 100 Mm Height Comprising All Required Standard Accessories. , Providing & Erecting Hot Dipped Galvanised Ladder Type Cable Tray Manufactured From 16 Swg (1.6 Mm Thick) Gi Sheet Of 200 Mm Width & 100 Mm Height Comprising All Required Standard Accessories. , Providing & Erecting Hot Dipped Galvanised Ladder Type Cable Tray Manufactured From 16 Swg (1.6 Mm Thick) Gi Sheet Of 150 Mm Width & 100 Mm Height Comprising All Required Standard Accessories , Providing & Erecting Floor/Wall Mounting, Mccb Panel Board, With Door, Suitable For Four Pole Incoming 250A, 8 Ways Four Pole Outgoing, Up To 100 A Mccbs On Iron Frame, As Per Specification No Sw-Swr/Mccbpb. (Excluding Mccbs) , Providing & Erecting Floor/Wall Mounting, Mccb Panel Board, With Door, Suitable For Four Pole Incoming 250A, 12 Ways Four Pole Outgoing, Up To 100 A Mccbs On Iron Frame, As Per Specification No. Sw-Swr/Mccbpb. (Excluding Mccbs) , Providing & Erecting Epoxy Straight Through Joint Outdoor/Indoor For Lt Xlpe Armoured Cable 70 To 95 Sq Mm., With Necessary Material As Per Specification No. Cb-Jt/Lt , Providing & Erecting Epoxy Straight Through Joint Outdoor/Indoor For Lt Xlpe Armoured Cable 25 To 50 Sq Mm., With Necessary Material As Per Specification No. Cb-Jt/Lt , Providing & Erecting Epoxy Straight Through Joint Outdoor/Indoor For Lt Xlpe Armoured Cable 2.5 To 16 Sq Mm., With Necessary Material As Per Specification No. Cb-Jt/Lt , Providing & Erecting Epoxy Straight Through Joint Outdoor/Indoor For Lt Xlpe Armoured Cable 120 To 185 Sq. Mm., With Necessary Material As Per Specification No. Cb-Jt/Lt , Providing & Erecting 9 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 200 Mm A/F, Top 100 Mm A/F On Provided Foundation As Per Specification No. Oh-Pl/Opl , Providing & Erecting 9 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 155 Mm A/F, Top 70 Mm A/F On Provided Foundation As Per Specification No. Oh-Pl/Opl , Providing & Erecting 8 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 135 Mm A/F, Top 70 Mm A/F On Provided Foundation As Per Specification No. Oh-Pl/Opl , Providing & Erecting 7 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 200 Mm A/F, Top 100 Mm A/F On Provided Foundation As Per Specification No. Oh-Pl/Opl , Providing & Erecting 7 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 130 Mm A/F, Top 70 Mm A/F On Provided Foundation As Per Specification No. Oh-Pl/Opl , Providing & Erecting 6 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 130 Mm A/F, Top 70 Mm A/F On Provided Foundation As Per Specification No. Oh-Pl/Opl , Providing & Erecting 5 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 130 Mm A/F, Top 70 Mm A/F On Provided Foundation As Per Specification No. Oh-Pl/Opl. , Providing & Erecting 4 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 130 Mm A/F, Top 70 Mm A/F On Provided Foundation As Per Specification No. Oh-Pl/Opl , Providing & Erecting 3 Pole Mccb, 415 V, 100A, Rated Short-Circuit Breaking Capacity 25 Ka (Ics=100% Of Icu), Adjustable Thermal (Overload) Setting And Fixed Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/Uv/Trip Alarm Contact. Mccb With Phase Barriers On Both Sides, Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure/Panel As Per Specification No. Sw-Swr/Mccb , Providing & Erecting 3 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 130 Mm A/F, Top 70 Mm A/F On Provided Foundation As Per Specification No. Oh-Pl/Opl , Providing & Erecting 12 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 240 Mm A/F, Top 90 Mm A/F On Provided Foundation As Per Specification No. Oh-Pl/Opl , Point Wiring In Pvc Trunking (Casing-Capping) With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wire, Flush Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw/Sw , Point Wiring In For Light/Fan/Bell In 20 Mm Metal Conduit With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wire, Flush Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw/Sw , Point Wiring For Light/Fan/Bell In 20 Mm Frls Grade Hms Pvc Conduit With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wire With Flush Type Switch And Required Accessories As Per Specification No: Wg-Pw/Sw , Point Wiring For Light/Bell/Exhaust Fan In Pvc Trunking (Casing-Capping) With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw/Sw , Point Wiring For Light/Bell/Exhaust Fan In 20 Mm Frls Grade Hms Pvc Conduit With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg , Point Wiring For Light/Bell Hybrid Type (Surface Type Under False Ceiling And Concealed Type For Drops & Switch Boards On Walls) In Min 20 Mm Pvc Conduit / Casing N Capping With 1.5 Sq.Mm. (2+1E) Frlsh Grade Copper Wires, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg , Point Wiring For Light/Bell Concealed Type In Min 20 Mm Frls Grade Hms Pvc Conduit With 1.5 Sq.Mm. (2+1E) Frlsh Grade Copper Wires, Modular Type Switch, Earthing And Required Accessories As Per Specification No: WgPw/Cw , Point Wiring For Independent Plug, Concealed Type In Min 20 Mm Frls Grade Hms Pvc Conduit With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wires, Modular Type Switch, Earthing And Required Accessories As Per Specification No Wg-Pw/Sw , Point Wiring For Independent Plug In Pvc Trunking (Casing-Capping) With 1.5 Sq.Mm Frlsh Grade Copper Wire, Flush Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw/Sw , Point Wiring For Independent Plug In Pvc Trunking (Casing-Capping) With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw/Sw , Point Wiring For Independent Plug In 20 Mm Metal Conduit With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wire, Flush Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw/Sw , Point Wiring For Independent Plug In 20 Mm Frls Grade Hms Pvc Conduit With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wire, Flush Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw/Sw , Point Wiring For Independent Plug In 20 Mm Frls Grade Hms Pvc Conduit With 1.5 Sq.Mm (2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw/Sw , Point Wiring For Ceiling Fan In Pvc Trunking (Casing-Capping) With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw/Sw , Point Wiring For Ceiling Fan In 20 Mm Frls Grade Hms Pvc Conduit With 1.5 Sq.Mm (2+1E) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw/Sw , Point Wiring For Ceiling Fan Concealed Type In Min 20 Mm Frls Grade Hms Pvc Conduit With 1.5 Sq.Mm. (2+1E) Frlsh Grade Copper Wires, Modular Type Switch, Earthing And Required Accessories As Per Specification No: WgPw/C , Point Wiring For Ceiling Fan (Surface Type Under False Ceiling And Concealed Type For Drops & Switch Boards On Walls) In Min 20 Mm Pvc Conduit / Casing N Capping With 1.5 Sq.Mm. (2+1E) Frlsh Grade Copper Wires, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw/Hw , Making Trench In Soft Soil Having 0.9M Depth And Minimum 0.3 M Width As Per Is For Laying Provided Cables Of Voltage Range 3.3 Kv To 11 Kv Complete As Per Specification No. Cw-Exn-Ctr , Making Trench In Hard Murum/Tar Road Having 0.9 M Depth And Minimum 0.3Mtr Width For Laying Provided Cables Of Voltage Range 3.3 Kv To 11 Kv Complete As Per Specification No. Cw-Exn-Ctr , Making Trench In Hard Murum/Tar Road Having 0.75 M Depth And Minimum 0.3Mtr Width As Per Is For Laying Provided Cables Up To Voltage Level 1.1Kv Cable Complete As Per Specification No. Cw-Exn-Ctr , Making Transformer Plinth (1.5 X 1.5 X 1.5) M In Size With Necessary Excavation In Ground With 150 Mm. Thick M- 10 Pcc At The Bottom And Top And 250 Mm. Thick, Burnt Brick Wall Constructed At Periphery And Remaining Hollow Portion Shall Be Filled With 40Mm Hard Broken Aggregate. External Surface Duly Plastered By 12 Mm Thick Including Watering Etc Complete , Making M- 20 Grade Reinforced Cement Concrete Foundation By Considering The Safe Soil Bearing Capacity At Site As 10 T/Sq.M At 1.5 M Depth Including Supply Of Steel, Concrete, Excavation And Fixing Provided Nut Bolts With The Help Of Template, Duly Plastered As Per Design Complete (For 6M To 8M High Octagonal /Conical Gi Pole). , Making M- 20 Grade Reinforced Cement Concrete Foundation By Considering The Safe Soil Bearing Capacity At Site As 10 T/Sq. M At 1.5 M Depth Including Supply Of Steel, Concrete, Excavation And Fixing Provided Nut Bolts With The Help Of Template, Duly Plastered As Per Design Complete ( For 11M & 12.5M High Octagonal /Conical Gi Pole). , Making M- 20 Grade Reinforced Cement Concrete Foundation By Considering The Safe Soil Bearing Capacity As 10 T/Sq.M At 1.5 M Depth Including Supply Of Steel, Concrete, Excavation, Fixing Provided Nut Bolts With The Help Of Template, Duly Plastered As Per Design Complete (For 3 To 5M Octagonal / Conical Gi Pole). , Making M- 20 Cement Concrete Foundation By Considering The Safe Soil Bearing Capacity At Site As 10 T/Sq. M At 2 M Depth Including Excavation And Fixing Provided Nut Bolts With The Help Of Template, Duly Plastered As Per Design Complete (For 16 M Raising Lowering High Mast). , Making M- 20 Cement Concrete Foundation By Considering The Safe Soil Bearing Capacity At Site As 10 T/Sq. M At 2 M Depth Including Excavation And Fixing Provided Nut Bolts With The Help Of Template, Duly Plastered As Per Design Complete (For 12.5 M Raising Lowering High Mast). , Making Cement Concrete Foundation Including Excavation (60 X 60) Cm X Deep 1/6 Of Pole Length In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, 45 Cm X 45 Cm X 45 Cm /45 Cm Dia. X 45 Cm. Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. (For Above 9 M Poles) , Making Cement Concrete Foundation Including Excavation (60 X 60 X 150) Cm Deep In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, (45 X 45 X 45) Cm /45 Cm Dia. X 45 Cm Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. (Above 6 M To 9 M Poles) , Making Cement Concrete Foundation Including Excavation ( 45 X 45 X 120 ) Cm Deep In 1:3:6 Cement Concrete, 20 To 25 Mm Stone Metal, (45 X 45 X 45) Cm / 45 Cm Dia. X 45 Cm Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. (For 6 M Pole) , Making Cement Concrete Foundation In 1:3:6 Cement Concrete, (20 To 25) Mm. Stone Metal Duly Plastered With Necessary Curing For Complete. (Pole Muffing Or Any Other Purpose). , Excavating Hard Rock Or Bituminous Road By Chiselling For Preparing Pit For Pole / Stay/Earth Plate / For Laying Cable/ Pipe & Clearing The Site By Removing Debris & Making The Site As Required Complete. , Concealing Of Provided G.I. Pipe/H.G. Screwed Conduit/Pvc Pipe In Wall/Floor/False Ceiling Complete As Per Specification No:Wg-Pw/Cw , Making M- 20 Grade Reinforced Cement Concrete Foundation By Considering The Safe Soil Bearing Capacity At Site As 10 T/Sq.M At 1.5 M Depth Including Supply Of Steel, Concrete, Excavation And Fixing Provided Nut Bolts With The Help Of Template, Duly Plastered As Per Design Complete (For 9M & 10M High Octagonal /Conical Gi Pole).

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-May-2023 MATHERAN ELETRICAL MATERIAL SUPPLY ONE CONDITION ADD Technical Bid 25-05-2023

Key Value

Document Fees
INR 3000 /-
EMD
INR 20000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:?? ????-?? ?? ????????? ?????????? ??????? ??????? ????? ??????? ????
Sl. No. Item Description
1Supplying & erecting crimping type copper lugs for cable 70 sq mm complete as per specification No. CB-CL/CU
2Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz, 800 to 900VA digital pure sine wave inverter with backup time of ........ hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV
3Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz, 700VA digital pure sine wave inverter with backup time of ........ hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV
4Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz, 2500 VA digital pure sine wave inverter with backup time of ........ hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV
5Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz, 1400 to 1600VA digital pure sine wave inverter with backup time of ........ hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV
6Supplying, installing, testing and commissioning 11kV HRC Fuse 10A to 40A for load break switch with necessary nut bolts complete.
7Supplying, installing, testing and commissioning 11 kV HRC Fuse 63A for load break switch with necessary nut bolts complete.
8Supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.5 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
9Supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum 3.5 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC
10Supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum 3.1 to maximum 3.29 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP
11Supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 0.7TR to 0.9TR capacity having ISEER minimum 3.1 to maximum 3.29 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP
12Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
13Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
14Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
15Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
16Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
17Supplying, installing, testing & commissioning IP EPABX for 10 extensions complete.
18Supplying, installing, testing & commissioning digital (hybrid) type EPABX of 6 x 16 extension complete.
19Supplying, installing, testing & commissioning digital (hybrid) type EPABX of 3 x 8 extensions complete.
20Supplying, installing, testing & commissioning analogue type EPABX of 3 x 8 extension complete.
21Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850LPM at 80 to 60 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 45kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-"F" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP
22Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 1600 to 1800 LPM at 70 to 55 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 30kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-"F" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP
23Supplying, installation, testing and commissioning 3 phase, 22/0.433 kV, 50 Hz., 315 kVA, indoor type, vacuum cast coil (VCC) dry type cast resin Transformer, Copper wound , Dyn11 vector group, delta/star connection with additional neutral brought out on load side, for indoor use continuous duty, average temp rise of winding (at Principal Tap) 115°C at ambient temp max 50°C & Min -5°C at full load rating, with Tapping (with off circuit bolted links type tap changer) for off load +5 to - 5% @ 2.5% in +2/-2 steps, HV variation, class of insulation H/H, method of cooling AN, no load loss at rated voltage & frequency (+15% IS Tol) 1.80 kW, full load loss at rated current 3.00 kW, with 98.50 % efficiency at full load & 98.41 % at 1/2 full load, with 125 kV peak full wave lightning impulse withstand voltage with complete enclosure having IP 23 degree of protection, cable box arrangement at HV side & bus duct at LV side ,with rating & diagram plate, base channel, lifting lugs, earthing terminals & WTI scanner with 3 PT-100 sensors, etc. standard accessories complete with test certificate (as per IS:11171 & IEC 60076-11) with necessary permissions of Electrical Inspector, as per specification no. SS- TR.
24Supplying, installation, testing and commissioning 3 phase, 11/0.433 kV, 50 Hz., 315 kVA, indoor type, vacuum cast coil (VCC) dry type cast resin transformer, Copper wound , Dyn11 vector group, delta/star connection with additional neutral brought out on load side, for indoor use continuous duty, average temperature rise of winding (at principal tap) 115oC at ambient temp max 50oC and min -50oC at full load rating, with tapping (off circuit tap links type tap changer), for off load +5 to - 5% @ 2.5% in +2/-2 steps, HV variation, class of insulation H/H, method of cooling AN, no load loss at rated voltage and frequency (+15% IS ToI) 1 kW, full load loss at rated current 3.15 kW, with 98.70% efficiency at full load & 98.88 % at 1/2 full load, with 75 kV peak full wave lightning impulse withstand voltage with complete enclosure having IP 21 degree of protection, cable box arrangement at HV side and bus duct at LV side, with rating and diagram plate, base channel, earthing terminals and WTI scanner with 3 PT-100 sensors, etc., standard accessories complete with test certificates (as per IS:11171 & IS 2026) with necessary permissions of Electrical Inspector as per specification no. SS- TR.
25Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI
26Supplying, fixing, and configuring modularised multi-service router 802.11/a/n/ac unified Wave 2.5 GHz, with RJ-45 port, supporting 1 to 13 channels for 2.4 GHz, with unified wireless access point complete
27Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WGNWC/GBS
28Supplying, fixing, and configuring 24 ports + 4 (SFP+) port, Managed Layer 2, POE Switch of , 370W, 6KV surge protection on ethernet port and console port for management erected in provided rack complete.
29Supplying, fixing, and configuring 20 SFP ports + 4 Combo SFP 10/100/1000 Base-T erected in provided rack complete.
30Supplying, fixing, and configuring 20 (1G-RJ45) ports + 4 combo 1G ports + 4 10G (SFP+) ports, Layer 3 switch, SI Image, 6KV surge protection on ethernet port and console port for management erected in provided rack complete.
31Supplying, fixing and commissioning MCB type change over switch 4 pole, 63A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS
32Supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kVA capacity online pure sine wave UPS, with backup time of ....... hrs. PWM & IGBT based, with 0.8 to unity output pf complete with all protections as per specification no. AP-UPS
33Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 82.5 kVA up to 100 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
34Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 62.5 kVA up to 82.5 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
35Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 50 kVA up to 62.5 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
36Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 40 kVA up to 50 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
37Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 35 kVA up to 40 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
38Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 25 kVA up to 35 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
39Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 20 kVA up to 25 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
40Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 15 kVA up to 20 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
41Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 125 kVA up to 140 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
42Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 100 kVA up to 125 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
43Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 10 kVA up to 15 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF.
44Supplying, erecting, testing and commissioning of Diesel generating set with standard control Panel with alternator of 5 kVA continuous rating, single Phase, 230V, 50c/s 0.8 p. f. AC supply a totally enclosed air / liquid cooled multi cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours with standard accessories, self-excited, selfregulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption of 1.3 Ltr/hr @75% loading. Engine and alternator directly coupled on a common fabricated steel base plate with anti-vibrating pad, with control panel comprising of standard meters, switchgears, indicators connected with suitable wires/cables. The complete set enclosed in acoustic enclosure made of 18 SWG CRCA sheet, sound absorbing material, rockwool covered from inside with ¾ mm holes perforated sheet to restrict sound level up to 75 dB at 1.0 m. The engine with first filling of oil, diesel not less than 13 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
45Supplying, erecting, testing and commissioning of diesel generating set with alternator of 82.5 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 14.0 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 145 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
46Supplying, erecting, testing and commissioning of diesel generating set with alternator of 62.5 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 11.3 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 150 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
47Supplying, erecting, testing and commissioning of diesel generating set with alternator of 50 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 9.98 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 150 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
48Supplying, erecting, testing and commissioning of diesel generating set with alternator of 40 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 7.47 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 75 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
49Supplying, erecting, testing and commissioning of diesel generating set with alternator of 30 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 5.9 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 65 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
50Supplying, erecting, testing and commissioning of diesel generating set with alternator of 25 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 5.0 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 65 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
51Supplying, erecting, testing and commissioning of diesel generating set with alternator of 200 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 34.40 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB(A) at 1.0 m, provided with first filling of oil, diesel not less than 300 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
52Supplying, erecting, testing and commissioning of diesel generating set with alternator of 20 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption of 3.8 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 50 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
53Supplying, erecting, testing and commissioning of diesel generating set with alternator of 15 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption of 3.0 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on antivibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 40 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
54Supplying, erecting, testing and commissioning of diesel generating set with alternator of 100 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 17.4 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 230 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
55Supplying, erecting, testing and commissioning of diesel generating set with alternator of 10 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption of 2.4 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising of meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 40 Ltr etc. on provided M20 Grade CC Foundation as per specification No. GEN-DG
56Supplying, erecting, testing and commissioning of 6kVA capacity online pure sine wave with backup time of ....... hrs. PWM & IGBT based UPS with 0.9 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS
57Supplying, erecting, testing and commissioning of 3kVA capacity online pure sine wave with backup time of ....... hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS
58Supplying, erecting, testing and commissioning of 2kVA capacity online pure sine wave, with backup time of ....... hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS
59Supplying, erecting, testing and commissioning of 28HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
60Supplying, erecting, testing and commissioning of 20HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56°C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
61Supplying, erecting, testing and commissioning of 12HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
62Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
63Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 70 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
64Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
65Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
66Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
67Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 50 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
68Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
69Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
70Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
71Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
72Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
73Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
74Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
75Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
76Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
77Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
78Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
79Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
80Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
81Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
82Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
83Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
84Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
85Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
86Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
87Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
88Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
89Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
90Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
91Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
92Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V 2 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
93Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
94Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
95Supplying, erecting & marking SPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
96Supplying, erecting & marking SPMCB 40A to 63A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
97Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
98Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
99Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
100Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
101Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
102Supplying, erecting & commissioning MDF Box 600x600 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
103Supplying, erecting & commissioning MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
104Supplying, erecting & commissioning MDF Box 500x500 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
105Supplying, erecting & commissioning MDF Box 400x400 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
106Supplying, erecting & commissioning MDF Box 300x300 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
107Supplying, erecting & commissioning MDF Box 250x250 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
108Supplying, erecting & commissioning MDF Box 200x200 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
109Supplying, erecting & commissioning MDF Box 150x150 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
110Supplying, erecting & commissioning MDF Box 100x100 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
111Supplying, erecting & commissioning 4 pole RCCB 80A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
112Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
113Supplying, erecting & commissioning 4 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
114Supplying, erecting & commissioning 4 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
115Supplying, erecting & commissioning 4 pole RCCB 100A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
116Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
117Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
118Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
119Supplying Table fan of A.C. 230 V. 50 cycles 400 mm. oscillating type with speed regulator complete with 2 meter of 3 core flexible wire and Hand shield type 3 pin plug top.
120Supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM without speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin6A. plug top complete with moisture proof treatment and ‘E’ class insulation.
121Supplying pedestal type air circulator 450 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM with speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin 5A. plug top complete with moisture proof treatment and ‘E’ class insulation.
122Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4W-6W LED including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty.
123Supplying double door refrigerator domestic type of 300 to 360 litres storage capacity, minimum 5 Star inverter type, stabilizer free operation suitable for operation on 100V/300 V, 50Hz with automatic temperature control, shall be marked on unit for sealed unit in refrigeration system and marking sr. no. and date of erection complete.
124Supplying and plugging 3 m fibre patch cord LC-SC MM (50) OM4 LSZH duplex complete as per specification no. WG-COC/FPC
125Supplying and plugging 3 m fibre patch cord LC-SC MM (50) OM3 LSZH duplex complete as per specification no. WG-COC/FPC
126Supplying and plugging 3 m fibre patch cord LC-LC MM (50) OM4 LSZH duplex complete as per specification no. WG-COC/FPC
127Supplying and plugging 3 m fibre patch cord LC-LC MM (50) OM3 LSZH duplex complete as per specification no. WG-COC/FPC
128Supplying and laying rigid steel conduit 16 SWG 32 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No: WGMA/CC.
129Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
130Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete
131Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
132Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
133Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete.
134Supplying and fixing wireless n 150 desktop adapter in provided computer as per specification No. WG-NAS/LANC2
135Supplying and erecting VPIT heavy duty copper wound ballast 230V for 80- 150W HPSV/MV/MH as per specification no. FG-FG/AS5.
136Supplying and erecting VPIT compound heavy duty copper wound ballast for 230V for 250W HPSV/MV/MH as per specification no. FG-FG/AS5.
137Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
138Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
139Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background
140Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
141Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
142Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background
143Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background
144Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system.
145Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)
146Supplying and erecting two pole power contactor 230 V, 32 A for time switch complete erected on provided wooden block/ box, with necessary materials.
147Supplying and erecting two pole power contactor 230 V, 12 A for time switch complete erected on provided wooden block/ box, with necessary materials.
148Supplying and erecting two pole metal clad changeover switch 240 V, 32 A erected on angle iron/GI frame and duly connected with suitable wire leads complete
149Supplying and erecting triple pole mini feeder pillar with 500V, 200A FPMCCB as incomer and 2 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles, self locks, gasket having IP54,IK10 protection and slanting top to be erected on provided foundation complete as per specification no. SW
150Supplying and erecting T8 Fluorescent tube day light 1200mm, 36 W
151Supplying and erecting T5 24 W energy efficient fluorescent tube.
152Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB
153Supplying and erecting street light Wall bracket made from 25 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB
154Supplying and erecting Street light bracket made from 40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC
155Supplying and erecting Street light bracket for erection of Single fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FG-BKT/BPC
156Supplying and erecting Street light bracket for erection of Double fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FGBKT/BPC
157Supplying and erecting storage type water heater 50 litres capacity having standing loss<0.675 kWh/24hour/45°C, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal cut-out, function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no.AP-WH/STWH
158Supplying and erecting storage type water heater 25 litres capacity having standing loss <0.511kWh/24hour/45°C, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank, heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal function cut-out, valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. AP-WH/STWH
159Supplying and erecting storage type water heater 15 litres capacity having standing loss <0.419 kWh / 24 hour / 45°C, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal cut-out, multi function valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. AP-WH/STWH
160Supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm. thickness (5+2.5+2.5 m) length respectively and total 10 m long with pole cap, base plate in provided foundation (weight 160 kg) as per specification no. OH-PL/STP
161Supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.5 x 3.65 mm thickness ( 5+2+2 m ) length respectively and total 9 m long with pole cap, base plate in provided foundation (weight 147 kg) as per specification no. OH-PL/STP
162Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (5+1.75+1.75 m) length respectively and total 8.5 m long with pole cap, base plate in provided foundation. (weight 109 kg.) as per specification no. OH-PL/STP
163Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (4.5+1.75+1.75 m) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. (weight 101 kg) as per specification no. OH-PL/STP
164Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5 x 3.65 x 3.25 mm thickness (5+2+2 m ) length respectively and total 9 m long with pole cap, base plate in provided foundation (weight 113 kg) as per specification no. OH-PL/STP
165Supplying and erecting static energy meter with 3 x 240V 50 Hz. AC supply 10 to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display, (Measuring and display Trivector, V, I, kW, PF, Hz, Last month history of kWh and MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power & with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company.
166Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
167Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
168Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
169Supplying and erecting shockproof T. switch 16 A porcelain base surface mounting type / flush mounting type erected on filled polypropylene board or polished thick varnished double wooden block/folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with S M screws and duly connected.
170Supplying and erecting shockproof piano type switch 250 V, 16 A, erected on filled polypropylene board or polished double wooden/ folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with S M screws and duly connected.
171Supplying and erecting shockproof bell push on filled polypropylene board or wooden block covered with sunmica with 2 core (TRS type) PVC insulated copper wire of size 0.5 sq mm 5 m length connected to the point.
172Supplying and erecting shockproof 6A porcelain base T.Switch / bell push erected on filled polypropylene board or polished double wooden block / 3 mm thick hylam sheet / 4mm thick plywood pasted with 1.5 mm thick laminate with S M screws and duly connected
173Supplying and erecting shockproof 3 pin plug socket 6A with porcelain base / flush type erected on filled polypropylene board or polished thick varnished double wooden block / folded or screwed board with top of either wooden / 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with S M screws and duly connected.
174Supplying and erecting shockproof 3 pin plug socket 16A with porcelain base/ flush type erected on filled polypropylene (IS:14772-2000) board or polished thick varnished double wooden block / folded or screwed board with top of either wooden/3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with S M screws and duly connected.
175Supplying and erecting rigid steel conduit 16 SWG 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
176Supplying and erecting rigid steel conduit 16 SWG 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
177Supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. FG-FN/CF
178Supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. FG-FN/CF
179Supplying and erecting rectangular shaped LED Panel Light(1200mm X 300mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
180Supplying and erecting recess type, 3 pin plug socket 6A with piano switch 6A erected on M.S Box made of 16 SWG sheet duly painted and covered with bakelite hylam sheet of 3 mm thickness connected with earth terminals and leads duly concealed
181Supplying and erecting recess type, 3 pin plug socket 6A with piano switch 6 A combined unit erected on polished double wooden block/ folded or screwed board with top of either wooden or plywood pasted with sunmica and with connecting leads
182Supplying and erecting quartz electronic time switch having 24 hour dial to work on 250 V 50 cycle AC having built in rechargeable nickel cadmium batteries to run the time switch on failure of supply having switch contact rating up to 16A to use independently or in conjunction with contactor.
183Supplying and erecting PVC trunking (PVC casing-n-capping) of size 40 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
184Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON
185Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
186Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected
187Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected.
188Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected.
189Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module duly erected.
190Supplying and erecting PVC Surface modular switch box with double mounting plate for 16 / 18 module duly erected.
191Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module duly erected.
192Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected.
193Supplying and erecting PVC Surface modular switch box with double mounting & front plate for 8 module complete duly connected.
194Supplying and erecting PVC Surface modular double mounting plate 8 module complete duly erected.
195Supplying and erecting PVC Surface modular double mounting plate 6 module complete duly erected.
196Supplying and erecting PVC Surface modular double mounting plate 4 module complete duly erected
197Supplying and erecting PVC Surface modular double mounting plate 3 module complete duly erected.
198Supplying and erecting PVC Surface modular double mounting plate 2 module complete duly erected.
199Supplying and erecting PVC Surface modular double mounting plate 16/18 module complete duly erected.
200Supplying and erecting PVC Surface modular double mounting plate 12 module complete duly erected
201Supplying and erecting PVC Surface modular double mounting plate 1 module complete duly erected.
202Supplying and erecting PVC slotted box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification No: WG-MA/SLBOX.
203Supplying and erecting PVC slotted box trunking of size 45x30 mm. with accessories on wall/ceiling as per specification No: WG-MA/SLBOX.
204Supplying and erecting PVC slotted box trunking of size 100x100 mm. with accessories on wall/ceiling as per specification No: WG-MA/SLBOX.
205Supplying and erecting PVC box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX.
206Supplying and erecting PVC box trunking of size 100x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX .
207Supplying and erecting programmable digital almanac timer microcontroller based with real time clock to operate on derived switching “ON” and switching “OFF” street light as per daily sunset and sunrise respectively automatically having 4 digit LED continuous time display, relay output 230 V / 10A with 10 hrs. battery backup and manual over drive facility capable to drive different capacity contactors timer erected in provided M.S. box.
208Supplying and erecting porcelain base iron clad cut out HC type 415V, 63A erected on polished wooden block.
209Supplying and erecting porcelain base iron clad cut out HC type 415V, 32A erected on polished wooden block.
210Supplying and erecting porcelain base iron clad cut out HC type 415V, 200A erected on polished wooden block.
211Supplying and erecting porcelain base iron clad cut out HC type 415V, 16A erected on polished wooden block.
212Supplying and erecting porcelain base iron clad cut out HC type 415V, 100A erected on polished wooden block.
213Supplying and erecting pole clamp made from 50x6mm MS flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of red oxide and two coats of aluminium paint complete.
214Supplying and erecting pole clamp made from 50x10mm MS flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of red oxide and two coats of aluminium paint complete.
215Supplying and erecting plywood 6 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete.
216Supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete.
217Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 63A TPN MCB incomer, 24hr astronomical time switch with minimum 5 Years battery backup, , IP 54 and IK10 protection, 45 A TP contactor for automatic switching of luminaires, 2 no 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box powder coated with supporting angles, self lock, gasket and slanting top erected on CC foundation complete.
218Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 32A TPN MCB incomer, 24hr astronomical time switch with minimum 5 years battery backup, IP 54 and IK10 protection, 25 A TP contactor for automatic switching of luminaires, 2 no. 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation complete.
219Supplying and erecting One/Two way piano type switch 6A./bell push erected on filled polypropylene board or double polished wooden board/ folded or screwed board with top of either wooden/ 3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5 mm thick laminate with S M screws and duly connected.
220Supplying and erecting modular type Two way switch 6A / 10A (2 Module), duly erected on provided plate and box with wiring connections complete
221Supplying and erecting modular type telephone socket two gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
222Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete
223Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
224Supplying and erecting modular type switch one way 16 / 20 A, duly erected on provided plate and box with wiring connections complete with neon indicator.
225Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
226Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
227Supplying and erecting modular type indicator lamp, duly erected on provided plate and box with wiring connections complete.
228Supplying and erecting modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete
229Supplying and erecting modular type buzzer 220 / 250V, duly erected on provided plate and box with wiring connections complete
230Supplying and erecting modular type blanking plate two module, duly erected on provided plate & box
231Supplying and erecting modular type bell-push with indicator 2 modules 6A / 10A, duly erected on provided plate and box with wiring connections complete.
232Supplying and erecting modular type bell-push 6A / 10A duly erected on provided plate and box with wiring connections complete.
233Supplying and erecting modular type bell indicator, duly erected on provided plate and box with wiring connections complete.
234Supplying and erecting modular type 6 / 16A fuse unit, duly erected on provided plate and box with wiring connections complete.
235Supplying and erecting modular type 32A, DP key tag switch with key tag, duly erected on provided plate and box with wiring connections complete.
236Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections
237Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
238Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
239Supplying and erecting modular type (two module) electronic dimmer 600/650W, duly erected on provided plate and box with wiring connections complete.
240Supplying and erecting modular type (two module) electronic dimmer 1000W, duly erected on provided plate and box with wiring connections complete.
241Supplying and erecting modular type (one module) electronic dimmer 400 / 450W, duly erected on provided plate and box with wiring connections complete.
242Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete
243Supplying and erecting Metal Halide lamp double ended 230V, 70 W .
244Supplying and erecting Metal Halide lamp double ended 230V, 250 W.
245Supplying and erecting Metal Halide lamp double ended 230V, 150 W .
246Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010
247Supplying and erecting mains with WP 4 x 4 sq. mm. 1100 V. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire.
248Supplying and erecting mains with WP 3 x 6 sq. mm. 1100 V. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire.
249Supplying and erecting mains with WP 3 x 4 sq. mm. 1100 V. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire.
250Supplying and erecting mains with WP 2 x 4 sq. mm. 1100 V grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire.
251Supplying and erecting mains with WP 2 x 2.5 sq. mm. 1100 V grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire.
252Supplying and erecting mains with 4x25 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
253Supplying and erecting mains with 4x16 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
254Supplying and erecting mains with 3x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
255Supplying and erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
256Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
257Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
258Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
259Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
260Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
261Supplying and erecting M.S. pipe pole ‘B’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. OH-PL/GIP
262Supplying and erecting luminous / modular type call bell indicator with plastic body, heavy duty coil and indicator lamp working on 230V A.C. supply with resetting arrangement complete erected on double wooden/ sunmica board.
263Supplying and erecting LSZH armoured multimode optical fibre cable with 6 fibres, core dia 50/125 µm (OM4) suitable up to 10 GBPS ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC
264Supplying and erecting LED Strip light 5m Length Max. 95 W IP20 class having minimum lumens output of 1600 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD0.95, operating range of 230-270V, Life class of 30,000 Hrs. at L70B50 including driver with 1 year warranty.
265Supplying and erecting LED Strip light 5m Length Max. 45 W IP20 class having minimum lumens output of 800 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD0.95, operating range of 230-270V, Life class of 30,000 Hrs. at L70B50, including driver with 1 year warranty.
266Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
267Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty
268Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty
269Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty
270Supplying and erecting LED square / circular Max. 11 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
271Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty
272Supplying and erecting LED Panel Light(600mm X 600mm) Max. 30 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty
273Supplying and erecting integrated LED street light fitting 85-90W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 9300 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
274Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
275Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
276Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
277Supplying and erecting integrated LED street light fitting 26 to 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing , having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
278Supplying and erecting integrated LED street light fitting 23 to 25W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 2300 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3Years warranty as per specification No FG-ODF/FLS2.
279Supplying and erecting integrated LED street light fitting 18 to 22W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 1800 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD0.95, operating range of 140- 270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG
280Supplying and erecting integrated LED street light fitting 160-170W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 19000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD0.95, operating range of 140- 270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FGODF/FLS2.
281Supplying and erecting integrated LED street light fitting 120W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 13000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
282Supplying and erecting integrated LED street light fitting 100-110W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 11000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
283Supplying and erecting integrated LED Post Top 45W IP65 & IK10 class having die cast aluminium housing with UV protected polycarbonate diffuser, having system lumens output of Min.4500 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 30,000 Hrs. at L50B50 , including driver complete with 2 Year warranty as per specification No FGODF/FLS
284Supplying and erecting integrated LED Highbay Fitting 135W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of Min. 20000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD0.90, operating range of 140-240V, inbuilt surge protection of 4kV, Life class of 50,000 Hrs. at L50B50 , including driver complete with 3 Year warranty as per specification No FG-ODF/FLS2.
285Supplying and erecting integrated LED flood light fitting Max. 70W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 8400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
286Supplying and erecting integrated LED flood light fitting Max. 50W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 5000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
287Supplying and erecting integrated LED flood light fitting Max. 30W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 3000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
288Supplying and erecting integrated LED flood light fitting Max. 195W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
289Supplying and erecting integrated LED flood light fitting Max. 155W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 18600 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
290Supplying and erecting integrated LED flood light fitting Max. 120W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min.14500 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
291Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
292Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 800mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 25,000 Hrs. at L50B50, including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2.
293Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 500mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 25,000 Hrs. at L50B50, including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2.
294Supplying and erecting ignitor suitable for 230V HPSV lamp 70/150/250/400W as specification no. FG-FG/AS6
295Supplying and erecting HPSV lamp 3 pin BC/Screwed cap head /pin type 230V, 70 W SON-T-type.
296Supplying and erecting HPSV lamp 3 pin BC/Screwed cap head /pin type 230V, 250 W SON-T-type.
297Supplying and erecting HPSV lamp 3 pin BC/Screwed cap head /pin type 230V, 250 W SON type.
298Supplying and erecting HPSV lamp 3 pin BC/Screwed cap head /pin type 230V, 150 W SON-T-type.
299Supplying and erecting HPSV lamp 3 pin BC/Screwed cap head /pin type 230V, 150 W SON type.
300Supplying and erecting HPSV lamp 3 pin BC/Screwed cap head / pin type 230V, 70 W SON type.
301Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with PVC accessories on wall / ceiling as per specification No: WG-MA/CON.
302Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
303Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON.
304Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.
305Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
306Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
307Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
308Supplying and erecting Gate/garden light fitting with 300mm dia. glass bowl suitable for upto 12W LED Lamp on provided pipe as per specification No. FG
309Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6mm., straining screws, G.l. stay wire 7/10 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete.
310Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws, G.l. stay wire 7/8 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete.
311Supplying and erecting G.I. self stay set for pole, including anchor plate 300x300x6mm straining screw, loop-insulator, G.l. stay wire 7/10 SWG, G.l. stay rod 20mmx1.8m long, erected with pole clamps along with angle iron bracket of 50x50x6mm and one meter long fixed to pole at suitable height with suitable MS clamps duly erected in provided C.C. foundations complete.
312Supplying and erecting G.I. pipe pole ‘B’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. OH-PL/GIP
313Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
314Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings complete as per specification no. FF-PP
315Supplying and erecting G.I. pipe ‘C’ class ERW 20 mm dia with necessary fittings complete as per specification no. FF-PP
316Supplying and erecting G.I. fly stay set for pole including straining screw, G.l. stay wire, 7/10 SWG (for to 15m long) with pole clamp, made of 50x6mm MS flat, erected on provided RSJ pole complete. (Add. Rs. 25/- per m for extra length beyond 15 m)
317Supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160-270V and output voltage 200-250V rated for, 1kVA maximum load and with voltmeter, selector switch, 6A/16A flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16A plug top suitable for with overload & short circuit protection complete.
318Supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160-270V and output voltage 200-250V rated for 4kVA maximum load and with voltmeter, selector switch, 6A/16A flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16A plug top with overload & short circuit protection complete.
319Supplying and erecting fully automatic line voltage stabilizer buck and boost type for operation on input voltage 160-270V and output voltage 200-250V rated for 3kVA maximum load and with voltmeter, selector switch, 6A/16A flush type 3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16A plug top with overload & short circuit protection complete.
320Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.
321Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.
322Supplying and erecting four pole power contactor 430 V, 40 A for time switch complete erected on provided wooden block/ box, with necessary materials.
323Supplying and erecting four pole power contactor 430 V, 16 A for time switch complete erected on provided wooden block/ box, with necessary materials.
324Supplying and erecting flush, shock proof plug socket 6 pin 6A and 16A with switch 16A combined unit erected in recess in 16 gauge M.S sheet box duly painted and connected with earth terminal and leads
325Supplying and erecting flush type, shockproof plug socket 6 pin 6A and 16A with switch 16A combined unit erected on filled polypropylene board or double wooden block / 3mm thick hylam sheet / 4mm thick plywood pasted with 1.5 mm thick sunmica with S M screws and duly connected.
326Supplying and erecting flush type shockproof plug socket 6A & 16A (6 pin) with 16A switch combined with indicator lamp and fuse with gang box on wooden board.
327Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.
328Supplying and erecting exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF
329Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF
330Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 1400 RPM complete erected in position as per specification no. FG-FN/EXF
331Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 375/380 mm. 1400 RPM complete erected in position as per specification no. FG
332Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
333Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD
334Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board.
335Supplying and erecting electronic type Driver for Outdoor LED Fittings upto 25W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%.
336Supplying and erecting electronic type Driver for Outdoor LED Fittings 76W100W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and TH
337Supplying and erecting electronic type Driver for Outdoor LED Fittings 46W75W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<1
338Supplying and erecting electronic type Driver for Outdoor LED Fittings 26W45W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and
339Supplying and erecting electronic type Driver for Outdoor LED Fittings 151W200W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%.
340Supplying and erecting electronic type Driver for Outdoor LED Fittings 101W150W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD
341Supplying and erecting electronic ignitor suitable for 230V metal halide lamp 70/150/250/400W (integral or non integral type luminaires as specification no. FG-FG/AS6
342Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.
343Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EAEP.
344Supplying and erecting Control gear for NON Integral Flood light fittings suitable for 2x250W HPSV/MH lamp with all accessories complete.
345Supplying and erecting Control gear for NON Integral Flood light fittings suitable for 1x400W HPSV/MH lamp with all accessories complete.
346Supplying and erecting condenser for MV/SV/MH lamp 250W,230V as specification no. FG-FG/AS7
347Supplying and erecting condenser for MV/SV/MH lamp 150W,230V as per specification no. FG-FG/AS7
348Supplying and erecting Ceiling rose / Batten holder / Slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/ PVC junction box.
349Supplying and erecting cabin fan of A.C. 230 V. 50 cycles 400 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc.
350Supplying and erecting cabin fan of A.C. 230 V. 50 cycles 250 mm. /300 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc.
351Supplying and erecting C type (half) clamps for pole made from 50x6mm flat for fixing cross arms by means of 15mm bolts and nuts painted with one coat of red oxide and two coats of aluminium paint complete.
352Supplying and erecting C type (half) clamps for pole made from 50x10mm flat for fixing cross arms by means of 15mm bolts and nuts painted with one coat of red oxide and two coats of aluminium paint complete.
353Supplying and erecting bracket fan 400 mm. sweep A. C. 230 volts 50 cycles 1350 RPM. Oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘E’ class insulation.
354Supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete.
355Supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint with joints required as per specification no EA-EP.
356Supplying and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 RPM with speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 Volts single phase, 50 cycles A.C. supply, with one meter of 3 core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation.
357Supplying and erecting acrylic sheet 3 mm thick to be used for covering the CRCA sheet boxes etc. including cutting, drilling, and pasting or fixing with nut bolts/ screws etc. complete.
358Supplying and erecting 75 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC
359Supplying and erecting 50 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC
360Supplying and erecting 40 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC
361Supplying and erecting 3m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.
362Supplying and erecting 30 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC
363Supplying and erecting 3 phase 4 core 50 sq.mm. (3x50+1x35) Aerial bunched aluminium cable along with necessary accessories for LT distribution on provided LT pole as per specification no. OH-CBL/ABC
364Supplying and erecting 3 phase 4 core 35 sq.mm. (3x35+1x25) Aerial bunched aluminium cable along with necessary accessories for LT distribution on provided LT pole as per specification no. OH-CBL/ABC
365Supplying and erecting 3 phase 4 core 25 sq.mm. (3x25+1x25) Aerial bunched aluminium cable along with necessary accessories for LT distribution on provided LT pole as per specification no. OH-CBL/ABC
366Supplying and erecting 3 phase 4 core 16 sq.mm. (3x16+1x25) Aerial bunched aluminium cable along with necessary accessories for LT distribution on provided LT pole as per specification no. OH-CBL/ABC
367Supplying and erecting 20m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.
368Supplying and erecting 16 m (clear height) motorized high-mast (Top-150mm, Bottom-410 mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN -10025 S 355/E350 & 3 mm thickness, with base plate 25 mm thick x OD 570 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 6 mm, SG-DG U clamps, double drum winch assembly 350 kg, 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 16 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete. specification no. OHPL/HM (excluding luminaries)
369Supplying and erecting 16 m (clear height) motorized high-mast (Top-150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN -10025 S 355/E350 & 3 mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum winch assembly 350 kg, 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete. specification no. OHPL/HM (excluding luminaries
370Supplying and erecting 12V/80Ah to 88Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete
371Supplying and erecting 12V/7Ah -7.5Ah SMF battery with battery terminal wire, duly charged with 12 months warranty complete
372Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete
373Supplying and erecting 12V/26Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete
374Supplying and erecting 12V/200Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete
375Supplying and erecting 12V/180Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete
376Supplying and erecting 12V/17Ah -18Ah SMF battery with battery terminal wire, duly charged with 12 months warranty complete
377Supplying and erecting 12V/150Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete.
378Supplying and erecting 12V/130Ah to 135Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete.
379Supplying and erecting 12V/100Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete.
380Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.
381Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S 355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as per specification no. OHPL/HM (excluding luminaries
382Supplying and erecting 12 V/65Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete
383Supplying and erecting 11 kV outdoor type gang operated air break, triple pole switch 200 A capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of "C" class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp.
384Supplying and erecting 10m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.
385Supplying and erecting 100 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating , APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no CP-ED/APFC
386Supplying and erecting ‘D’ type pole clamps, fabricated from 50x6mm MS flat with 15mm bolts and nuts fixed to steel tubular pole duly painted with one coat of red oxide and two coats of aluminium paint complete.
387Supplying and drawing of 2x1.5 sq.mm. FRLSH grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes for concealed type light/bell point wiring and terminating on modular accessories in box for point wiring for light/fan/bell as per specification No: WG-PW/CW
388Supplying and drawing of 2x1.5 sq.mm. FRLSH grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes for concealed type fan point wiring and terminating on modular accessories in box as per specification No: WG-PW/CW
389Supplying and drawing of 2x1.5 sq.mm. FRLSH grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes and terminating on modular accessories in box for point wiring for independent plug as per specification No WG-PW/SW
390Supplying 230/250V, 50Hz, evaporative air cooler (desert cooler) having normal cooling capacity of 80cu.m per minute, with 12" exhaust, min 75 to 80 litres water capacity tank with galvanised steel sheet with grade 350 minimum, leak or drip free, front grill shall be made of non-corrosive material, circular opening shall be more than fan sweep but not exceeding more than 25mm, filter pads shall be made of wood wool or any other substitute placed in non-corrosive wire mesh and tightened at places with side panels, noise level should not be more than 65dBA at 1m distance, 3 core copper cable minimum 2m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed metallic parts, shall be provided with proper earthling complete as per specification no. AP-WCR/DAC
391Supplying 230/250V, 50Hz, evaporative air cooler (desert cooler) having normal cooling capacity of 60 to 70 cu.m per minute, with 12" exhaust, min 68 litres water capacity tank with galvanised steel sheet with grade 350 minimum, leak or drip free, front grill shall be made of non-corrosive material, circular opening shall be more than fan sweep but not exceeding more than 25mm, filter pads shall be made of wood wool or any other substitute placed in non-corrosive wire mesh and tightened at places with side panels, noise level should not be more than 65dBA at 1m distance, 3 core copper cable minimum 2m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed metallic parts, shall be provided with proper earthling complete as per specification no. AP-WCR/DAC
392Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(UE), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
393Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(UE), 3 x 120 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
394Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
395Supplying , erecting & terminating 11 kV(E), 3 x 70 sq. mm., aluminium conductor XLPE insulated, galvanised steel formed wire armoured (strip) cable laid in provided trench / pipe as per specification no. CB-HT
396Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
397Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
398Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete
399Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete
400Supplying & erecting water tight terminal box of cast iron of size 300 x 200 x 150 mm complete on pole as per specification No. CB-SB
401Supplying & erecting water tight terminal box of 1.6 mm (16 gauge) CRCA sheet of size 300 x 200 x 150 mm complete on pole as per specification No. CB
402Supplying & erecting water tight terminal box of 1.6 mm (16 gauge) CRCA sheet of size 150 x 100 x 100 mm complete on pole as per specification No. CB
403Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
404Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
405Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
406Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
407Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
408Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 12 ways /36 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
409Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
410Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation.
411Supplying & erecting three phase, 415V, street light control panel up to the max load of 12kW, TPN MCB 63A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation.
412Supplying & erecting street light control panel outdoor type, for three phase 4 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery back up, having IP54,IK10 protection, 4 pole contactor up to 60A, with maintenance mode to switch ON street lights during time of repairs with energy consumption data recording for analysis and LCD display for energy monitoring with numeric key pad in provided box.
413Supplying & erecting street light control panel outdoor type, for single phase 2 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery back up, having IP54,IK10 protection, 2 pole contactor up to 60 A, with maintenance mode to switch ON street lights during time of repairs with energy consumption data recording for analysis and LCD display for energy monitoring with numeric key pad in provided box.
414Supplying & erecting single pole cut point channel set of for 11kV HT OH line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing.
415Supplying & erecting single phase, 240V, street light control panel up to the max load of 6kW, SPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame/ CC foundation.
416Supplying & erecting single phase, 240V, street light control panel up to the max load of 12kW, SPN MCB 63A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation & overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation.
417Supplying & erecting single compression type brass cable glands for 4 core 35 Sq.mm./3 core 50 Sq.mm. for XLPE armoured cable as per specification no. CB-GL
418Supplying & erecting single compression type brass cable glands for 3½ core 95 sq mm for XLPE armoured cable as per specification No. CB-GL
419Supplying & erecting single compression type brass cable glands for 3½ core 70 sq mm for XLPE armoured cable as per specification No. CB-GL
420Supplying & erecting single compression type brass cable glands for 3 to 4 core 6 sq mm /2 to 4 core 10 sq mm for XLPE armoured cable as per specification No. CB-GL
421Supplying & erecting single compression type brass cable glands for 3 to 4 core 16 sq mm /3 to 4 core 25 sq mm /3 core 35 sq mm for XLPE armoured cable as per specification No. CB-GL
422Supplying & erecting single compression type brass cable glands for 2 to 4 core 2.5 sq mm /2 to 4 core 4 sq mm /2 core 6 sq mm for XLPE armoured cable as per specification No. CB-GL
423Supplying & erecting ready to use Retrofit T8 LED 18 / 20 tube light with polycarbonate body, heat sink, integrated HF electronic driver complete & compatible to T8 / T12 LED luminaire by disconnecting starter & ballast if necessary.
424Supplying & erecting MS pole bracket for LT OH conductor fabricated from 65x65x6 mm section, 550mm long for necessary nos. of provided insulators and erecting o
425Supplying & erecting MS pole bracket for guarding/LT OH line, fabricated from ISM channel 75x40x6mm and 550mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT
426Supplying & erecting MS pole bracket for guarding/LT OH line, fabricated from ISM channel 75x40x6mm and 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT
427Supplying & erecting MS pole bracket for guarding/LT OH line, fabricated from angle iron 50x50x6mm and 550mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT
428Supplying & erecting MS pole bracket for guarding/LT OH line, fabricated from angle iron 50x50x6mm and 1100mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT
429Supplying & erecting Minimum three & above star rated Centrifugal water pump (Monoblock), 415V, three phase 50 cycles A.C. supply of 2.25 KW/3 HP with discharge 600/110 Litres per Minute (LPM) for head of 13/43 m and 65 mm suction/ 50 mm delivery pipe on provided C.C. foundation as per specification No. WP-CGP
430Supplying & erecting Minimum three & above star rated Centrifugal water pump (Monoblock), 415V, three phase 50 cycles A.C. supply of 1.5 KW/2 HP with discharge 600/140 Litres per Minute (LPM) for head of 8/22 m and 50 mm suction/ 40 mm delivery pipe on provided C.C. foundation as per specification No. WP-CGP
431Supplying & erecting minimum three & above star rated Centrifugal water pump (Monoblock), 415 V, three phase 50 cycles A.C. supply of 5.625 KW/7.5 HP with discharge of 780/170 Litres per Minute (LPM) for head of 33/54 m and 80mm suction/ 65mm delivery pipe of size, on provided C.C. foundation as per specification No. WP-CGP
432Supplying & erecting minimum three & above star rated Centrifugal water pump (Monoblock), 415 V, three phase 50 cycles A.C. supply of 3.75 KW/5 HP with discharge 715/200 Litres per Minute (LPM) for head of 17/39 m and 65 mm suction/ 50 mm delivery pipe on provided C.C. foundation as per specification No. WP-CGP
433Supplying & erecting Minimum three & above star rated Centrifugal water pump (Monoblock), 230V, Single phase 50 cycles A.C. supply of 1.125 kW/1.5HP with discharge 198/50 Litres per Minute (LPM)) for head of 15/37.5 m & 40 mm suction/ 32 mm delivery pipe on provided C.C. foundation as per specification No. WP-CGP
434Supplying & erecting integral post top lantern fixtures (mushroom type) suitable for LED lamp upto 12 W consisting of clear acrylic top cover, cast aluminium pole cap complete with accessories on provided pole /bracket as per specification no. FG-ODF/PTL
435Supplying & erecting integral post top lantern fixtures (light house type) suitable upto LED 18 W Lamp consisting of combination of spun aluminium canopy & clear acrylic top cover, cast aluminium pole cap on provided pole/ bracket as per specification no. FG-ODF/PTL
436Supplying & erecting integral post top lantern fixtures (globe type) suitable for LED lamp upto 12 W consisting of aesthetic round clear acrylic top cover, cast aluminium pole cap on provided pole /bracket as per specification no. FG
437Supplying & erecting inline D.P. Structure for 11/0.415kV, 63kVA Transformer with RSJ pole 2 nos. of size 100x116mm x 11m long with suitable distribution box of CRCA sheet 16 SWG with 4 pole MCCB 100A as incomer & 6 nos. 63A kitkat/MCCB for outing circuits. Transformer D.P. Structure includes the A.B. switch 200A, D.O. fuse set & L.A. set. 2 nos. top channel of size 100x50mm for erection of A.B. Switch & 2 nos. base channel of size 100x50mm for erecting Transformer channel of size 75x40mm for erecting D.O. fuse set, L.A., A.B. switch handle etc. Angle of size 50x50x6mm for erecting distribution box, Transformer belt etc. as per drawing (min. 124 Kg. iron work ) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. with caution board & barbed wire, D.P. structure shall be erected in c.c. foundation complete.
438Supplying & erecting inline D. P. Structure for 11/0.415 kV, 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 300 Amps as incomer & 6 Nos. 100 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos of Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 mm for erecting Transformer Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work ) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete.
439Supplying & erecting inline D. P. Structure for 11/0.415 kV, 100 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 200 Amps as incomer & 6 Nos. 100 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. of Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 mm for erecting Transformer Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work ) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire, D.P. Structure shall be erected in c.c. foundation complete
440Supplying & erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
441Supplying & erecting G.I. pipe ‘A’ class 50 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
442Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
443Supplying & erecting G.I. pipe ‘A’ class 25 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
444Supplying & erecting Fully Automatic Star/delta starter suitable for 12.5 H.P to 15 H.P. for 3 phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame.
445Supplying & erecting FRP box of size 300mm x 200mm x 125 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB
446Supplying & erecting FRP box of size 250mm x 200mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB
447Supplying & erecting FRP box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB
448Supplying & erecting four pole ON LOAD change over switch, 415V, 63A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3.
449Supplying & erecting four pole ON LOAD change over switch, 415V, 40A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle,operational current category AC23A complying to IS/IEC 60947-3 Part-1/3.
450Supplying & erecting four pole ON LOAD change over switch, 415V, 32A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3 .
451Supplying & erecting four pole ON LOAD change over switch, 415V, 315- 320A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3.
452Supplying & erecting four pole ON LOAD change over switch, 415V, 200A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3.
453Supplying & erecting four pole ON LOAD change over switch, 415V, 160A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3.
454Supplying & erecting four pole ON LOAD change over switch, 415V, 100A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3.
455Supplying & erecting flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
456Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
457Supplying & erecting flat flexible 3 core 2.5 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
458Supplying & erecting flat flexible 3 core 10 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
459Supplying & erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply up to 7.5 H.P.
460Supplying & erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with no volt coil and overload element with necessary materials and connected to supply for 10 H.P.
461Supplying & erecting D.O.L Starter suitable for 250 V, Single phase 50 cycles with overload element with necessary materials and connected to supply up to 3 H.P.
462Supplying & erecting crimping type copper lugs for cable up to 16 sq mm complete as per specification No. CB-CL/CU
463Supplying & erecting crimping type copper lugs for cable 70 sq mm complete as per specification No. CB-CL/CU
464Supplying & erecting crimping type copper lugs for cable 35 sq mm complete as per specification No. CB-CL/CU
465Supplying & erecting crimping type copper lugs for cable 25 sq mm complete as per specification No. CB-CL/CU
466Supplying & erecting crimping type aluminium lugs for cable up to 16 sq mm complete as per specification No. CB-CL/AL
467Supplying & erecting crimping type aluminium lugs for cable 95 sq mm complete as per specification No. CB-CL/AL
468Supplying & erecting crimping type aluminium lugs for cable 70 sq mm complete as per specification No. CB-CL/AL
469Supplying & erecting crimping type aluminium lugs for cable 50 sq mm complete as per specification No. CB-CL/AL
470Supplying & erecting crimping type aluminium lugs for cable 35 sq mm complete as per specification No. CB-CL/AL
471Supplying & erecting crimping type aluminium lugs for cable 25 sq mm complete as per specification No. CB-CL/AL
472Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 30 A, 3 pin plug & earth socket and 30A, 3 pin plug top with 30A triple pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron / GI frame.
473Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG11 as per specification No. WG-TW
474Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG
475Supplying & erecting cast iron cable indicator plate buried along with route of cable for PVC / XLPE armoured cable as per specification No. CB-CIP
476Supplying & erecting automatic control panel for 3 Ph, 415 volt, /centrifugal pump set up to 10 HP consisting of Star Delta starter having relay range 9-14 Amp, S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc.
477Supplying & erecting automatic control panel for 3 Ph, 415 volt, /centrifugal pump set up to 10 - 15 HP consisting of Star Delta starter having relay range 13- 22 Amp, S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc.
478Supplying & erecting 50 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
479Supplying & erecting 5 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
480Supplying & erecting 4 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
481Supplying & erecting 3 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
482Supplying & erecting 20 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier, laid in provided PVC casing capping/conduit as per specification No. WG-TW
483Supplying & erecting 20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
484Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
485Supplying & erecting 18W, 230V integral type LED Lamp suitable for B-22 / E
486Supplying & erecting 14W, 230V integral type LED Lamp suitable for B-22 / E27 base.
487Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / E-27 base.
488Supplying & erecting 100 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
489Supplying & erecting 10 pair, 0.5mm dia, jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier, laid in provided PVC casing capping/conduit as per specification No. WG-TW
490Supplying & erecting 10 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
491Supplying & erecting 0.5 mm dia, copper jumper wire as per specification No. WG-TW
492Supplying & arranging burnt cured bricks properly for various purposes (size 9”x4.25”x3”) at work for 100 bricks complete.
493Supply and erecting 9m (clear height) Fixed type high-mast (Top-100mm, Bottom- 200mm) with hexagonal /round bracket and foundation bolts suitable for max. 4 nos. flood light fixtures on provided foundation as per specification no. OH-PL/OPL (excluding luminaires).
494Rewinding the motor of the Exhaust fan 900 / 1400 RPM 300 mm of all types, makes and over hauling including minor repairs, lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year
495Rewinding the motor of the ceiling fan 1200 mm / 1400 mm of all types , makes and over hauling including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year.
496Rewinding the motor of table / pedestal / wall bracket / cabin fans of all type and makes including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. Testing for original speed and consumption with guarantee for 1 year including transportation from site and back
497Rewinding of electric motor upto 1 H.P. single phase up to 1400 RPM of all types, makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. testing for the original speed and no load consumption with guarantee for one year.
498Rewinding of electric motor up to 1 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year
499Rewinding of electric motor above 7.5 H.P. upto 10 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one yea
500Rewinding of electric motor above 5 H.P. upto 7.5 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year
501Rewinding of electric motor above 3 H.P.upto 5 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year
502Rewinding of electric motor above 2 H.P. upto 3 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year
503Rewinding of electric motor above 1 HP upto 2 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year
504Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
505Providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm.
506Providing recess in brick wall suitable for erection of exhaust fan up to 450 mm sweep complete with grouting of nut, bolts, plaster in hand colour washing to match the colour of the wall for the wall thickness of 150 mm.
507Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
508Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
509Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA
510Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
511Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete of medium duty (100 Kilogram).
512Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT
513Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
514Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
515Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 400 mm width & 100 mm height comprising all required standard accessories.
516Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 100 mm height comprising all required standard accessories.
517Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 100 mm height comprising all required standard accessories.
518Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standard accessories
519Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 8 ways Four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs)
520Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 12 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no. SW-SWR/MCCBPB. (Excluding MCCBs)
521Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 70 to 95 sq mm., with necessary material as per specification No. CB-JT/LT
522Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 25 to 50 sq mm., with necessary material as per specification No. CB-JT/LT
523Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 2.5 to 16 sq mm., with necessary material as per specification No. CB-JT/LT
524Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 120 to 185 sq. mm., with necessary material as per specification No. CB-JT/LT
525Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 200 mm A/F, top 100 mm A/F on provided foundation as per specification no. OH-PL/OPL
526Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
527Providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
528Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 200 mm A/F, top 100 mm A/F on provided foundation as per specification no. OH-PL/OPL
529Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
530Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
531Providing & erecting 5 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL.
532Providing & erecting 4 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
533Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
534Providing & erecting 3 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
535Providing & erecting 12 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 240 mm A/F, top 90 mm A/F on provided foundation as per specification no. OH-PL/OPL
536Point wiring in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW
537Point wiring in for light/fan/bell in 20 mm metal conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW
538Point wiring for light/fan/bell in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification No: WG-PW/SW
539Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
540Point wiring for light/bell/exhaust fan in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG
541Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG
542Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW
543Point wiring for independent plug, concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No WG-PW/SW
544Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW
545Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
546Point wiring for independent plug in 20 mm metal conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW
547Point wiring for independent plug in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW
548Point wiring for independent plug in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E ) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
549Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
550Point wiring for ceiling fan in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
551Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/C
552Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
553Making trench in soft soil having 0.9m depth and minimum 0.3 m width as per IS for laying provided cables of voltage range 3.3 kV to 11 kV complete as per specification No. CW-EXN-CTR
554Making trench in hard murum/Tar road having 0.9 m depth and minimum 0.3mtr width for laying provided cables of voltage range 3.3 kV to 11 kV complete as per specification No. CW-EXN-CTR
555Making trench in Hard murum/Tar road having 0.75 m depth and minimum 0.3mtr width as per IS for laying provided cables up to voltage level 1.1Kv cable complete as per specification No. CW-EXN-CTR
556Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete
557Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
558Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete ( for 11m & 12.5m high octagonal /conical GI pole).
559Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation, fixing provided nut bolts with the help of template, duly plastered as per design complete (for 3 to 5m octagonal / conical GI pole).
560Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 16 m raising lowering high mast).
561Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast).
562Making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles)
563Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles)
564Making cement concrete foundation including excavation ( 45 x 45 x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, (45 x 45 x 45) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (for 6 m pole)
565Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).
566Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete.
567Concealing of provided G.I. pipe/H.G. screwed conduit/PVC pipe in wall/floor/false ceiling complete as per specification No:WG-PW/CW
568Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 9m & 10m high octagonal /conical GI pole).
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail