Tender For Repair/ Replacement Of Lt Switch Gears, Mccbs, Acbs, Contactor, Apfc Panels, Security Lights Etc And Other Allied Works At Af Stn Dadri In Aor Of Ge (Af) Faridabad, dadri-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair/ Replacement Of Lt Switch Gears, Mccbs, Acbs, Contactor, Apfc Panels, Security Lights Etc And Other Allied Works At Af Stn Dadri In Aor Of Ge (Af) Faridabad. Submission Date for this Tender is 15-06-2023. Switch Gear Tenders in dadri Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

37740525
Corrigendum : Tender For Repair/ Replacement Of Lt Switch Gears, Mccbs, Acbs, Contactor, Apfc Panels, Security Lights Etc And Other Allied Works At Af Stn Dadri In Aor Of Ge (Af) Faridabad
Open Tender
Indian
Uttar Pradesh
dadri
15-06-2023

Tender Details

Repair/ Replacement Of Lt Switch Gears, Mccbs, Acbs, Contactor, Apfc Panels, Security Lights Etc And Other Allied Works At Af Stn Dadri In Aor Of Ge (Af) Faridabad

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work: REPAIR/ REPLACEMENT OF LT SWITCH GEARS, MCCBS, ACBS, CONTACTOR, APFC PANELS, SECURITY LIGHTS ETC AND OTHER ALLIED WORKS AT AF STN DADRI IN AOR OF GE (AF) FARIDABAD
Sl. No. Item Description
1Supply& fixing MCCBTPN 63 Amps 16 KA complete all as specified and directed by Engineer-in-Charge. Make of MCCB : Havells, L&T, Legrand, Schnedier
2All as per item No 01 above but 100 Amps 16 kA complete all as specified and directed by Engineer-in-Charge .
3All as per item No 01 above but125 Amps 415 Volts 16 kA complete all as specified and directed by Engineer-in-Charge
4Supply& fixing of MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-Charge. Make of MCCB : Havells, L&T, Legrand, Schnedier
5All as per item No 04 above butTPN 200 Amps 415 volts 36 kA complete all as specified and directed by Engineer-in-Charge.
6All as per item No 04above but TPN 250 Amps 415 volts 36 kA complete all as specified and directed by Engineer-in-Charge.
7All as per item No 04 above but TPN 400 Amps 415 volts 36 KA complete all as specified and directed by Engineer-in-Charge.
8Supply & Fixing in repair of Four Pole Contactor, 415V AC, 2 NO+NC,250 Amp, complete all as specified and directed by Engineer-in-Charge. Make of MCCB : Havells, L&T, Legrand, Schnedier
9All as per item No 08 above but 160 Amps complete all as specified and directed by Engineer-in-Charge.
10All as per item No 08 above but 100 Amp complete all as specified and directed by Engineer-in-Charge.
11All as per item No 08 above but capacity upto 63 Amp complete all as specified and directed by Engineer-in-Charge.
12S & FOFF load Change Over Switch250 Amps4 pole 415 Volt complete all as specified and directed by Engineer-in-Charge Make : Havells/L&T/Legrand
13Supply, installation , commissioning and testingof LTPanel Boardout door type factory made out of CRCAsheet 3.15 mm thick dust & vermin proof , frontand rear openingshutters having locking arrangementtotally enclosed weather proof, antirusted powder coated including aluminium Bus Barof 400 Ampsrating of suitable length, 440 volts, 3 Phase 4 wire50 Hz mountedon suitable type ofinsulators.complete withbottom removable gland plates, as required, all internalconnection wiring bymin. 2.5 Sqmm. copper wires, Panel shall be comprising ofseperate chambers / modules / compartment to accomodate incomer MCCB, outgoing MCCB andinstrument chamber comprise of digital Ammeter & voltmeter flush mounted, selector switches, RYB indicator ,CT"s,etc complete mounted on suitable size of MS angle framestandof minimum 450 cmheight from ground l;evelinclPCCand earhwork required to fix the stand complete all as specified and directed by Engineer-in-Charge. The panel board shall be comprising of the following :- (a) Incommer - MCCB 4 POLE 415 V 400 A (35 kA)- 02 Nos Outgoing :- (b) ON load Change over Switch 400 Amps 4 Pole -01 Nos (c)MCCB 4 POLE 415 V125 A (25 kA)- 04 Nos (d ) MCCB 4 POLE 415 V63 A (25 kA)- 03 Nos (e) Blank chamber - 01 Nos with din rail sutable for fixing03 Nos TP/TPN MCBs complete all as specified and directed by Engineer-in-Charge Make of panel:- UNIVERSAL,OSIAN, SMS, L&T Make of MCCB : Havells, L&T, Legrand, Schnedier
14M&L for repair/ maintenanance opening of APFC Panel, Cleaning of dust using blower & cleaning agents. Checking/Detecting, Removal of Faults, Re-wiring of old u/s wiring & Testing of Control Wiring complete as reqd and closing of AMF Panel after replacement of above u/s parts and testing on completion of job on existing load etc. Complete all as specified and directed by Engineer-in-Charge.
15Supply & Fixing in repair of APFC main Relaycapacity upto 115 KVAR ,complete all as specified and directed by Engineer-in-Charge
16Supply & Fixing in repair of APFC power Relay main capacity upto 115 KVAR , complete as directed and specified by Engineer in Charge.
17Supply & Fixing in repair of APFC Relay card capacity upto 115 KVAR, complete all as specified and directed by Engineer-in-Charge
18Supply & Fixing in repair of SMPS card 12 V DC capacity upto 115 KVAR ,complete as directed and specified by Engineer-in-Charge.
19Supply & Fixing in repair of CT 100/5 capacity, complete all as specified and directed by Engineer-in-Charge
20Supply & Fixing in repair of Indicator R-Y-B,complete all as specified and directed by Engineer-in-Charge
21Supply & Fixing in repair of Digital Volt Metercomplete all as specified and directed by Engineer-in-Charge
22Supply & Fixing in repair of 6 core 2.5 Sqmm complete all as specified and directed by Engineer-in-Charge.
23Supply & Fixing in repair of TP MCB 25 A complete all as specified and directed by Engineer-in-Charge.
24Supply & Fixing in repair ofMCB SP 6-32 A complete all as specified and directed by Engineer-in-Charge. Make: Havells, L&T, Legrand, Schnedier
25Supply & Fixing in repair ofReactors 5/10/15/20 complete complete all as specified and directed by Engineer-in-Charge.
26Supply & Fixing in repair ofPVC Exhaust fan 150mm complete all as specified and directed by Engineer-in-Charge.
27Supply & Fixing in repair ofRotary handle complete all as specified and directed by Engineer-in-Charge.
28M&L forpainting of old LT panels of any size and descreption with two coat anti corrosive synthetic enamelled smoke gray paint oras per existing condition required on site incl rubbing old surface with emery paper complete all as specified and directed by Engineer-in-Charge.
29M&L and testing in repair for Advance Maintenance Freeenvironment friendly chemical earthing as per IS 3043 with copper strip of size 40 x 6 mm, 3 mtr long, 50mm dia outer pipe of thickness 2mm filled with highly conducting metellic compound in gel foam and boath end sealed, electrolytic copper eathing electrodes. The earth pits shall be filled with sufficent quality ultra high conductive black fill compound with neccessary accessories like lockable pit cover and PVC 16 sqmm single core multistrand PVC insulated copper conductordrawn inHDPEpipe bore 25mm Includingtest point terminal block made of gun metal phosphorus bronze of size75 x 75 x 25 mm drilled and screwed including 3 Nos8 mm dia25 mm long hexagonal head screws and Hot dip galvanised sheet2 mm thick box of size 200x 100x 100 mm withHexagonal head screws 125 mm complete as required all as per standard practices and specifications complete all as specified and directed by Engineer-in-Charge. Note: The concrete pit shall be PCC 1:3:6 type c-140 mm thick precast cover slab of RCC (1:2:4) type B-1 using 20mm aggregate reinforced with 8mm TMT bars @ 10 cmm c/c on both sides with suitable cast iron handle shall be provided in liew of cost iron cover shown in the electrical plate No. 3 MES SSR Part - I
30S & F Earthinglead 25 x 4 mm GI strip including strip insulators complete all as specified and directed by Engineer-in-Charge.
31Taking out old UNSV LT UG cable fromtrench/wall all as per site required any type and size complete all as specified and directed by Engineer-in-Charge.
32M&L forXLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 Sqmm 3.5 coreincl thimbles as required with suitable size of calmps on wall/under trenches etc complete all as specified and directed by Engineer-in-Charge. Make : POLYCAB, HAVELLS,KEI INDUSTRIES PVT LTD, CCI
33All as above item ser No 32but95 Sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge.
34All as above item ser No 32but70 Sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge.
35All as above item ser No 32but50Sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge.
36All as above item ser No 32but25 Sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge.
37M & L forserching fault location of HT/LT UGcable415 Voltlaid in trenches /ductswith the help of eletronic fault locating machine comprising of surge generator pulse ,ECHO fault locator with freqency distance calculator etc incl transportation of machinary from Delhi cantt .Excavation in normal soil starta exposing the cable fault removal of deteriorated portion of the cable treating of cable of any size including disconnecting and re fixing cables with lugs complete all as specified and directed by Engineer-in-Charge.
38Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor typecomplete all as specified and directed by Engineer-in-Charge.
39All as item serNo 38 abovebut for cable of size 70 to 95 sq mmcomplete all as specified and directed by Engineer-in-Charge.
40All as item serNo 38 abovebut for cable of size 120 to 150 sq mmcomplete all as specified and directed by Engineer-in-Charge.
41S&F galvanised iron tubing light grade size 40 mm dia for protection of cables or mechanical protectionof earth strip laid under plinths/floors, road, paths, culverts, or fixed on walls, or along poles by means of MS clamps with necessary bolts, nuts and washers etc complete all as specified and directed by Engineer-in-Charge.
42All as per item No 41above butsize 50 mm dia complete all as specified and directed by Engineer-in-Charge.
43All as per item No 41 above butsize 80 mm dia complete all as specified and directed by Engineer-in-Charge.
44All as per item No41 above butsize100 mm dia complete all as specified and directed by Engineer-in-Charge.
45M&L for auguring of holes in true horizontal position under road by means of mechanical rig after doing ultrasound to prevent any damage to existing cable/pipe line coming in route 1.5 Mtr deep and not exceeding 50 Mtrs long incl laying HDPE pipe not less than 150mm dia complete all as specified and directed by Engineer-in-Charge.
46Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed by Engineer-in-Charge.
47Returning, filling, including spreading levelling and well ramming in layers not exceeding 25cm apart complete all as specified and directed by Engineer-in-Charge.
48Removing of surplus excavated soil to a distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
49M&L for sand cushoning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed by Engineer-in-Charge.
50M&L for sub class `B` bricks for cable protection complete all as specified and directed by Engineer-in-Charge.
51Demolition of cement concrete (unreinforced)in ground floor and pavings exceeding 15cm thickness but above ground floors complete all as specified and directed by Engineer-in-Charge.
52M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation for LT pole / foundation mass filling or path/hard standing etc as reqd on site complete all as specified and directed by Engineer-in-Charge.
53M&L for PCC 1:2:4 type B-2 using 20mm graded stone aggregate for coping of pole using extra cement for smooth finish including form work / foundation mass filling or path/hard standing etc as reqd on site complete all as specified and directed by Engineer-in-Charge.
54M&L for PCC 1:4:8 type D-2 (Using 40mm grade stone aggregate) as in bed for pole in foundation filling and mass concrete/ foundation mass filling or path/hard standing etcas reqd on site complete all as specified and directed by Engineer-in-Charge.
55Supplyand fixing Pillar light outdoor lampas reqd on site andtesting complete all as specified and directed by Engineer-in-Charge. Make :HAVELLS, POLYCAB, BAJAJ,PHILIPS
56M&L for Preparation of surface Distempering walls with cement paint one coat complete all as specified and directed by Engineer-in-Charge.
57M&L for Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes complete all as specified and directed by Engineer-in-Charge.
58S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size, complete all as specified and directed by Engineer-in-Charge.
59M&L forMachine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade complete all as specified and directed by Engineer-in-Charge.
60M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors complete all as specified and directed by Engineer-in-Charge .
61M&L for Preparation of surface Distempering walls with distemper oil emulsion one coat, complete all as specified and directed by Engineer-in-Charge.
62M&L for Brickwork with sub- class ‘B’ bricks straight or curved on plan exc 6 m mean radius, complete all as specified and directed by Engineer-in-Charge.
63M&L for cross arms (MC 75), bracings, supports, clapms and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one prime coat, one under coat and one finishing coat paint, complete all as specified and directed by Engineer-in-Charge.
64Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermalanagement in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge. Make:- PHILIPS,WIPRO,BAJAJ, HAVELLS
65Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics andquipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engineer-in-Charge. Make :-HAVELLS, BAJAJ, PHILIPS, CG
66Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics andquipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engineer-in-Charge. Make :-HAVELLS, POLYCAB, BAJAJ,PHILIPS
67Supply and fixingWiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVCnsulated copper conductor, single core cable in surface/ recessed as required 2x1.5 sq. mm + 1x1.0 sq. mm earth wire complete all as specified and directed by Engineer-in-Charge. Make:- FINOLEX,HAVELLS, HPL, POLYCAB,
68S & FStreet lightfactory fabricated junction box of size 300 x 160 x 250mm made out of 2mmm thick CRCA powder coated sheet, including 63 Amp three phase 4 wire having 4 nos of aluminium busbar including 6 A SP MCB. The box should have auto door lock facilitywith magnetic look fixed on pole using necessary fixing arrangement such as clamps, nuts, bolts, washers etc complete all as specified and directed by Engineer-in-Charge. Make :- Hensel
69Supply and fixing of street light bracket to fix the street light fitting made out of suitable dia(32/40mm) light grade GI pipe 2.0 mtr long suitable formounting of street light fittingson poles /wall incl provision of two Nos flate iron clamps made out bent to shape of 50x6mm flat iron and fixingnuts and bolts in positionincluding painting with two coats of aluminium paint over a coat of red oxide complete all as specified and directed by Engineer-in-Charge.
70Taking out old UNSV LT UG cable fromtrench/wall all as per site required any type and size complete all as specified and directed by Engineer-in-Charge.
71Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed by Engineer-in-Charge. Make:- POLYCAB, HAVELLS,KEI INDUSTRIES PVT LTD, CCI
72Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and directed by Engineer-in-Charge. Make:- POLYCAB, HAVELLS,KEI INDUSTRIES PVT LTD, CCI
73Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed by Engineer-in-Charge. Make:- POLYCAB, HAVELLS,KEI INDUSTRIES PVT LTD, CCI
74Supply,andfixingbus bar chamber 4 Wayoutdoor type with Digital volt meter, Digital Amp meter, R-Y-B indicating lamps factory made out of CRCAsheet dust & vermin proof , frontopeningdoor having locking arrangementtotally enclosed weather proof, antirusted powder coatedpaintedincludingaluminium Bus Barof 200 Ampsratingbus size 45 cmlong x 50mm wide x 15mm thick, 440 volts, 3 Phase 4 wire having suitable gap to connect the cables of size upto 95 Sqmm 3.5 coreand bus mountedon suitable type ofinsulators incl coloured insulating sleeve on eachcomplete withbottom removable gland plates for inccomming and out going cables,bus chamber mounted onMS angle stand made of MS angle 50mm x 50 mm x 5 mm and should having minimium 45 Cm gap below bus chamber incl necessaryPCC foundation work, complete all as specified and directed by Engineer-in-Charge. Make : SIEMENS, L&T, ABB,LEGRAND, UNIVERSAL,OSIAN, SMS
75Supplyand fixing LED Post top fitting40 Watt5700 K CCT IP 65powder coated aluminium die cast and spun aluminium with cleardiffuser suitable for landscape lighting inclmaking necessary arrangement for mounting fittingas reqd on site and testing complete all as specified and directed by Engineer-in-Charge. Make :HAVELLS, BAJAJ, PHILIPS, CG
76Supplyand fixing LED Bollard light fitting IP 54powder coated PDCaluminium body with opaldiffuser suitable for landscape lighting incl making necessary arrangement for mounting fittingas reqd on site andtesting complete all as specified and directed by Engineer-in-Charge. Make : HAVELLS, BAJAJ, PHILIPS, CG
77M&L for LT/HTpole painting two coated anti corrosive synthetic enamelled silver paint as per existing condition incl rubbing old surface with emery paper alternateblack andyellow 30 cm wide strip upto 1.5 mtr of poleabove ground leveland marking polenumberscomplete all as specified and directed by Engineer-in-Charge.
78Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type, complete all as specified and directed by Engineer-in-Charge
79Supply & Fixing in repair of Four Pole Contactor, Capacity 250 Amp, 415V AC, 2 NO+NC,complete all as specified and directed by Engineer-in-Charge. Make : SIEMENS, L&T, ABB, Havells, Legrand
80All as per item No 79 but capacity 160 Amps complete all as specified and directed by Engineer-in-Charge.
81All as per item No 79but capacity 100 Amps complete all as specified and directed by Engineer-in-Charge.
82All as per item No 79but capacity 32 Amps complete all as specified and directed by Engineer-in-Charge.
83S & FOFF load Change Over Switch250 Amps4 pole 415 Volt complete all as specified and directed by Engineer-in-Charge Make : Havells/L&T/Legrand/ Siemens
84M&L forSurface cleaning/site clearance n exc 15 cm in depth execept inSub stations area, trenches,sub station rooms two pole/ foure structure surroundings to make a over allpresentable condition complete all as specified and directed by Engineer-in-Charge.
85Supply & filling in Bty distil watersuitable for Bty Charginganytype complete all as specified and directed by Engineer-in-Charge.
86Supply and Fixing including repair/replacement of LED driver 230 volt single phase of 45/48 watt, driver life >= 25000 Hrs efficiency - 85%, with out put short circuit protection complete all as specified and directed by Engineer-in-Charge. Make – Havells/Halonix/Polycab
87Supply and Fixing including repair/replacement of LED light strip 230 volt single phase of 45/48 watt, driver life >= 25000 Hrs efficiency - 85%, with out put short circuit protection complete all as specified and directed by Engineer-in-Charge. Make – Havells/Halonix/Polycab
88M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion, complete all as specified and directed by Engineer-in-Charge.
89All as above item No 88but with earthinglead 25 x 4 mm GI strip complete all as specified and directed by Engineer-in-Charge.
90S & F Earthinglead 25 x 4 mm GI strip complete all as specified and directed by Engineer-in-Charge.
91All as per item No 90 above but eartinglead 32 x 6 mm GI strip complete all as specified and directed by Engineer-in-Charge.
92Supply, installation , commissioning and testingof LTPaneloutdoor type factory made out of CRCAsheet 3.15 mm thick dust & vermin proof , frontand rear openingshutters having locking arrangementtotally enclosed weather proof, antirusted powder coated including aluminium Bus Barof 320 Ampsrating of suitable length, 440 volts, 3 Phase 4 wire50 Hz mountedon suitable type ofinsulators.complete withbottom removable gland plates, as required, all internalconnection wiring bymin. 2.5 Sqmm. copper wires, Panel shall be comprising ofseperate chambers / modules / compartment to accomodate incomer MCCB, outgoing MCCB andinstrument chamber comprise of digital Ammeter & voltmeter flush mounted, selector switches, RYB indicator ,CT"s,etc complete mounted on suitable size of MS angle framestandof minimum 450 cmheight from ground l;evelinclPCCand earhwork required to fix the stand complete all as specified and directed by Engineer-in-Charge. The panel board shall be comprising of the following :- (a) Incommer - MCCB 4 POLE 415 V 160 A (35 kA)- 01 Nos Outgoing :- (b)MCCB 4 POLE 415 V32 A (25 kA)- 02 Nos (c ) MCCB 4 POLE 415 V63 A (25 kA) - 02 Nos (d)Blank chamber - 01 Nos with din rail sutable for fixing04 Nos TP/TPN MCBs complete all as specified and directed by Engineer-in-Charge Make of panel:- UNIVERSAL,OSIAN, SMS, L&T Make of MCCB : Havells, L&T, Legrand, Schnedier
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy