Tender For Repair/Maint Of Cooling Appliance And Misc Work, Repair/Maint Of Street Light Including Replacement Of Street Light Panel, Timer, Junction Box And Other Connected Works In Omq Area And Repair/Maint Including Replacement Of Building Securi

Issued by Statutory Bodies & Commissions/Committees · hasimara, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
08 Jun 2023
0 days left
EMD
72000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
hasimara → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair/Maint Of Cooling Appliance And Misc Work, Repair/Maint Of Street Light Including Replacement Of Street Light Panel, Timer, Junction Box And Other Connected Works In Omq Area And Repair/Maint Including Replacement Of Building Security Lights I

BOQ

Nature of Work : REPAIR/MAINT OF COOLING APPLIANCE AND MISC WORK, REPAIR/MAINT OF STREET LIGHTINCLUDING REPLACEMENT OF STREET LIGHT PANEL, TIMER, JUNCTION BOX AND OTHER CONNECTED WORKS IN OMQ AREA AND REPAIR/MAINT INCLUDING REPLACEMENT OF BUILDING SECURITY LIGHTS IN OMQ/SMQ AREA AT AFS HASIMARA
Sl. No. Item Description
1Taking down and servicing of window type AC of 1.5 to 2 TR capacity, any type/size/make/model cleaning and washing of condenser assembly with chemical andhigh pressure jet pump, checking and retightening of all electrical connections, replacement of nuts, bolts, screws, washers, internal wiringand refixing properly after servicing, complete all as specified and directed.Note : (i) Spare parts & gas charging shall be measured & paid seperately under respective items.
2Taking down and servicing of split (outdoor and indoor unit) type AC of 1.5/2 TR capacity of any type/size/make/model cleaning and washing of inddor and outdoor unit assembly by chemical and high pressure jet pump, checking, retightening of all electrical connections, replacement of nuts, bolts, screws, washers,internal wiring, gas charging valve,reassembling, realignment/refixing indoor and outdoor unit properly, refixing properly after repair, complete all as specified and directed.Note : (i) Spare parts & gas charging shall be measured & paid seperately under respective items.
3Taking down and servicing of defective water cooler of capacity 40 to 80 Ltrof any type/make/model and cleaning, washing condenser assembly with high pressure jet pump and cleaning, rubbing and washing of storage water tank, draining of dirty water silt, checking, retightening, all electrical connections, replacement of nuts, bolts, screws, washers, drainpipe, internal wiring and reassembling properly after repair, complete all as specified and directed.Note : (i) Spare parts & gas charging shall be measured & paid seperately under respective items.
4Taking down and servicing of refrigerators of 165 Ltr to 320 Ltr capacity, any type/size/make/model including replacement of unserviceable parts and cleaning, washing, condenser assembly, retighening all electrical connections, replacement of nuts, bolts, screw, washers, internal wiring, fixing properly bracket housing of capacitors and reassembling properly after repair, complete all as specified and directed.Note : (i) Spare parts & gas charging shall be measured & paid seperately under respective items.
5Material and labour for testing leakage of gas and replacement of damaged portion of copper pipe of any dia upto 30cm length, brazing by oxyaccetelene gas welding and good quality copper brazing rods or soldering damaged portion, flaring copper pipe, replacement of flare nut and pouring the nitrogen gas flushing to check the leakage in copper pipe lines, recharging suitable gas fully after complete removal of nitrogen gas on satisfactorily completion of leak test, reassembling and testing cooling of wholerefrigerator of any capacity/type and make, complete all as specified and directed.
6All as per item No 5 here-in-above but for window type AC with R-22 gas of any capacity/make/type/model, complete all as specified and directed.
7All as per item No 5 here-in-above but for water coolerwith R-134 gas of any capacity/make/type/model, complete all as specified and directed.
8All as per item No 5 here-in-above but for split type AC with R-22 gas of any capacity/make/type/mode/model, complete all as specified and directed.
9Supplyand fixing power unit with 20 Amps starter incl 4 model plate, 20A plug and socket, PVC box for mounting of power unit suitable for 20 Amps power unit and connection of electric supply and testing, complete all as specified and directed.
10M&L for sub main wiring of two run 4 Sqmm single core PVC insulated, unsheathed multistranded copper conductor cable FRLSH 1100 Volts grade, drawn through and including PVC conduit of suitable size medium duty including all conduit accessories (ISI marked) to the surfaces of the wall/ceiling including one run of 4 Sqmm single core PVC insulated unsheathed copper earth continuity conductorFRLSH 1100 Volt gradeincluding making good disturbed surface, complete all as specified and directed.(Note : Two runs of single core cable with one run of earth continuity conductor including PVC conduits accessories shall be measured and paid as one length.)
11M&L for sub main wiring of two run 6 Sqmm single core PVC insulated, unsheathed multistranded copper conductor cable FRLSH 1100 Volts grade, drawn through and including PVC conduit of suitable size medium duty including all conduit accessories (ISI marked) to the surfaces of the wall/ceiling including one run of 6 Sqmm single core PVC insulated unsheathed copper earth continuity conductor FRLSH 1100 Volt grade including making good disturbed surface, complete all as specified and directed.(Note : Two runs of single core cable with one run of earth continuity conductor including PVC conduits accessories shall be measured and paid as one length.)
12Dismantling and taking down from existing position window type AC 1.5/2 ton capacity and refixing the same in new position including necessary cutting opening, fixing, connecting, testing and making good disturbed surface of old position and new position etc, complete all as specified and directed.
13Dismantling and taking down from existing position split type AC of capacity 1.5/2 ton and refixing the same in new position including necessary cutting opening, fixing, connecting, testing andmaking good disturbed surface of old position and new position etc, complete all as specified and directed.Note : Necessary gas charging, mounting stand, drain pipe and copper tube will be paid and measured seperately.
14Taking down and dismantling the unserviceable blower motor from 1.5/2 TR window/split AC of any type including opening all outer caseand rewinding,heat varnishing the blower motor with super enamel copper wire of suitable gauge by taking out burnt winding and cleaning the iron core, complete all as specified and directed.
15All as per item No 14 here-in-above but blower motor of water cooler of capacity 40 to 80 Ltr, complete all as specified and directed.
16S & F in repair potential relay box suitable for refrigerator of any make/model/capacity, complete all as specified and directed.
17S & F in repair auto defrost thermostate switch suitable for refrigerator, complete all as specified and directed.Make:Ranutrol/Indfos/Denfos
18S & F in repairpigmay bulb (thick/thin thread) 230 Volt suitable for refrigerator, complete all as specified and directed.
19S & F in repairstrainer as per sample suitable for refrigerator, complete all as specified and directed.Make: Ranutrol/Indfos/Denfos
20S & F in repair harmetic sealed type compressor suitable for 180/230/310 Ltr refrigerator , complete all as specified and directed.Make : LG/Samsung/BPL/Hitachi
21S & F in repairfreezer fan motor single phase 230 Volt, 50 Hz suitable for refrigerator of capacity 280 to 310 Ltr, complete all as specified and directed.Make : Marathon Electric/Frac Master/M Bajaj Electric
22S & F in repair cooling coil assy suitable for 180 to 310 Ltr capacity refrigerator, complete all as specified and directed.
23S & F in repair defrost heater suitable for 180 to 310 Ltr refrigerator, complete all as specified and directed.
24S & F in repairtimer switch suitable for 180 to 310 Ltr refrigerator, complete all as specified and directed.
25S & F in repair bimetal unit assy suitable for 180 to 310 Ltr refrigerator, complete all as specified and directed.
26S & F in repairoverload protector relay as per sample for window type ACof any make/model 1.5 -2.0 TRcapacity, complete all as specified and directed.
27S & F in repair potential relay box type suitable for window AC, complete all as specified and directed.
28S & F in repair thermostate switch suitable for window type AC, complete all as specified and directed.
29S & Ffan motor, single phase 230 Volt, 50 Hz suitable for window AC, complete all as specified and directed.
30S & F in repair strainer of capillary tube suitable for window AC, complete all as specified and directed.
31S & F in repairharmetic sealed type compressor suitable for window AC of capacity 1.5 TR, complete all as specified and directed.Make : LG/Emerson/Hitachi/Voltas/BPL/Samsung/Carrier
32S & F in repair rotary compressor of 1.5 ton capacity suitable for split type AC of any make/model 1.5TRcapacity, complete all as specified and directed. Make :LG/Emerson/Hitachi/Voltas/BPL/Samsung/Carrier
33S & F in repair rotary compressor of 2.0 ton capacity suitable for split type AC of any make/model 2.0TRcapacity, complete all as specified and directed. Make :LG/Emerson/Hitachi/Voltas/BPL/Samsung/Carrier
34S & F in repair power contactor suitable for 1.5/2 ton capacity split / window AC, complete all as specified and directed.
35S & F in repairoutdoor fan motor, single phase 230 Volt, 50 Hz suitable for split AC 1.5/2.0 TR capacity, complete all as specified and directed.
36S & F in repair strainer of capillary tube suitable for split AC 1.5/2.0 TR capacity, complete all as specified and directed.
37S & F in repairPCB of non invertor ACwith complete accessories of any make/capacity, complete all as specified and directed.Make : LG/Samsung / Carrier / Weather Maker / Voltas
38S & F in repair multi terminal capacitor (50 + 6/50 + 4mfd) suitable for split AC (stating, running and fan combined), complete all as specified and directed.Make : LG/Samsung/Carrier/Weather Maker
39Supply & Fixingin repair PVC medium grade 15mm dia drain pipe for split AC as per existing, complete all as specified and directed.
40Supply & Fixingin repair PCB for outdoor unit of invertor AC model and make as per existing, complete all as specified and directed.
41Supply & Fixingin repair PCB for indoor unit of invertor AC model and make as per existing, complete all as specified and directed.
42Supply & Fixing in repair blower motor, Indoor unit, single phase 230 V suitable for window type AC 1.5 ton, complete all as specified and directed.
43S & F in repair in repair copper tube 1/4\", complete all as specified and directed.
44S & F in repair in repair copper tube 1/2\", complete all as specified and directed.
45S & F in repair in repair insulation tube 1/4\", complete all as specified and directed.
46S & F in repair in repair insulationtube 1/2\", complete all as specified and directed.
47S & F in repair in repair copper tube 5/8\", complete all as specified and directed.
48S & F in repair in repair insulation tube 5/8\", complete all as specified and directed.
49S & F in repair remote control suitable for 1.5/2 ton split/windowtype AC as per existing make, complete all as specified and directed.
50S & F in repair overload protector relay suitable for 40 to 80 Ltr water coolers of any make/model, complete all as specified and directed.
51S & F in repair potential relay box suitable for 40 to 80 Ltr water cooler, complete all as specified and directed.
52S & F in repair thermostate switch suitable for 40 to 80 Ltr water cooler, complete all as specified and directed.
53S & F in repair chromium plated brass push cock 1/2\" (inner/outer thread) dia suitable for water cooler of any capacity, complete all as specified and directed.
54S & F in repair 15mm dia PVC ball valve high pressure with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe suitable for water cooler of any capacity , complete all as specified and directed.
55S & F in repair 15mm dia stop cock, cast copper alloy chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union suitable for water cooler of any capacity, complete all as specified and directed.
56S & Fin repair fan motor, single, phase 230 volts 50 Hzsuitable for water cooler of 40/80 ltr cooling capacity, complete all as specified and directed.Make: Marathon Electric/Frac Master/M Bajaj Electric
57S & F in repair condenser unit assembly suitable for 40/80 ltr capacity water cooler, complete all as specified and directed.Make: Universal/Sarada/Keltron
58S & F in repair drain pipe PVC medium grade 25mm dia with 23mm GI clamp complete for water cooler, complete all as specified and directed.
59S & F in repair 15mm dia PVC cold water pipe with both ends brass/chromium coated socket suitable for water cooler, complete all as specified and directed.
60S & F in repair harmetic sealed compressor suitable for cooling capacity 40/80Ltr water cooler, complete all as specified and directed.(Make: LG/Samsung/Carrier)
61S & F in repair condensor unit assembly suitable for split AC 1.5 /2 ton capacity, complete all as specified and directed.
62S & Foutdoor blower fan blade suitable for split AC 1.5/2 ton, complete all as specified and directed.
63Repair/maintenance of voltage stabilizer of capacity upto 5 KVA including replacement of driving transformer input 160 to 280 Volts and output 240 volts (+ 1%) and automatic change over circuit etc, complete all as specified and directed. Note : Minor defective parts shall be replaced by the contractor and the rate of the same shall deemed to be included in quoted rate.
64Repair/maintenance of voltage stabilizer of capacity upto 2 KVA including replacement of driving transformer input 160 to 280 Volts and output 240 volts (+ 1%) and automatic change over circuit etc, complete all as specified and directed. Note : Minor defective parts shall be replaced by the contractor and the rate of the same shall deemed to be included in quoted rate.
65Supply and filling of refrigerant gas R-22 in factory sealed cylinder, complete all as specified and directed.
66Supply and filling of refrigerant gas R-134a factory sealed cylinder, complete all as specified and directed.
67Supply and filling of refrigerant gas R-32 factory sealed cylinder, complete all as specified and directed.
68Supply and filling of refrigerant gas R-410A factory sealed cylinder, complete all as specified and directed.
69S & F in repair split AC outdoor mounting stand as per existing, complete all as specified and directed.
70S & F in repairstarting capacitor 50-100 Mfd, complete all as specified and directed. Make : Keltron/Sarada/Usha
71S & F in repair running capacitor 30-50 Mfd, complete all as specified and directed. Make : Keltron/Sarada/Usha
72S & F in repair flexible PVC insulated 3 core4 SqmmFR PVC multistranded cables with copper conductor for voltage grade upto 1100 V, complete all as specified and directed.
73Supply & fixing in repair MCB single pole (SP) of capacity 6 Amps to 32 Amps, 240 Volts AC, breaking capacity 10 KA, \"C\" series, fixed in proper position, complete all as specified and directed.
74Supply & fixing in repairMCB Single Pole and Neutral (SPN) of capacity6 to 32Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixedin proper position, complete all as specified and directed.
75M & L for repairing of PCB of split/window type AC with changes of necessary item as required, complete all as specified and directed.Note for SL item No - 01 to75 contractor has to arrange theComprehensive maintenance ofday to daymaintenance of cooling appaliances at techical area of AF Stn Hasimara consisting of following and maintaining the records like details of complaints , completion of Job card/complaint slip on standard format and inluding completion reports of Job cardfrom users/department andincluding required tools and plants , minor electrical sparers like small piece of wire, insulaton tape, screws etcrequired to rectifify the complaints and attendingcomplaintsin various technical Accn/LABs, etc including andreplacing the spare parts in summer/cooling appliances, spares required shall be measured and paid seperately under respective items in BOQ completeas per the job card, complete all as specified and directed.Note (i): Contractor shall employ minmum one skilled technician with helper for 08 Hrs (one shift) per day (from 09.00 Hrs to 17: 00 Hrs) for 6 daysin a week during contract period except onsundays and public holidays approved by GE (AF) Hasimara irrespective of number of Job cards issued to contractor.(ii)The person employed bythe contractor has to check the fittings/fixtures, equipments and wiring as per the complaints/Job card, spares for replacement shall be measured and paid as supply only under respective items and no extra payment shall be done for checking/inspection of fittings .
76Supply and fixing LED street light fitting 40/45 Watt 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
77Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
78Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
79S & F junction box made from SMC/FRP sheet ready made of size 350X 250 X138mm with aluminium bus bar of 100 Amp capacity for RYB andhalf for neutral made in suitablesize fixed inside the junction box with necessary supporting insulators fixed on hylem sheet, MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete, entire assemblyfixed to pole /Wall with MS clamp 25 X 5mm and nuts & bolts, or inside the Copping of pole /Post top including MCB SP 6 Amp 10 KA 240 V - 1 No, with necessary sizecopper lugs for connecting cables from junction box to fittings, complete all as specified and directed.
80S & F junction box made from SMC/FRP sheet ready made of size Junction boxof size450 X 375X 200mm with aluminium bus bar of 200 Amp capacity for RYB andhalf for neutral made in suitablesize fixed inside the junction box with necessary supporting insulators fixed on hylem sheet ,MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete , entire assemblyfixed to pole/wall with MS clamp 25 X 5mm and nuts & bolts, including MCB SP 6 Amp 10 KA 240 V - 1 No, with necessary size copper lugs for connecting cables from junction box to fittings, complete all as specified and directed.
81S & F in repair cable 3 corePVC insulated unsheathed multistranded copper conductor of sie 1.5 Sqmm passing through PVC conduit from junction box to fitting, complete all as specified and directed.Note : PVC conduit shall be measured and paid seperately.
82S & F in repair rigid PVC non metalic conduit 20mm diaonpole with necessary bend elbow, couplers, check nuts, FI clamp 40 x 4mm and nuts & bolts, PVC flexible conduit, connected to junction box to fitting etc including painting to clamps, complete all as specified and directed.
83S & F in repair power contactors for street light after dismatling existing contactors from panel and connecting new contactors and making connection withincoming and outgoing MCCB/MCB for 3 pole power contactors, 40 Amp, ML- 3 ,2 NO+2 NC, complete all as specified and directed.
84All as per item No 83 here-in-above but 3 pole power contactors, 70 Amp , ML- 4 ,2 NO+2 NC, complete all as specified and directed.
85Supply and fix in repair timer for 24 hrs, complete all as specified and directed.
86Supply and fix in repairMCB 63Amp 4 pole, 10 KA \"C\" series, complete all as specified and directed.
87Supply and fixing post top lantern LED type20/25 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed.Make:Bajaj Cat No : BGCTNP 20 LED WH or Crompton Cat Part No:CPB-610 - 2557SL CA -NBK or equivalent model of make : Havell\"s/Wipro/Philips
88Supply and fixing post top lantern LED type40/45 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed.Make:Bajaj Cat No : BGCTNP 40 LED WH or Crompton Cat Part No:CPB-610 -40- 57SL CA -NBK or equivalent model of make : Crompton/Havell\"s/Wipro/Philips
89Supply and fixingbollard LED type 9/10/12 watt 230 watt volts AC outdoor type withnecessary foundationand connection strip complete with driver and lamp, complete all as specified and directed.Make:Bajaj Cat Part No :BGBOS 650 9W LED ww or Havell\"sCat Part No CONEBLS8WLED 830PSYMTOPC or Crompton Cat Part No: LBLA1-10-CDL or equivalent model of make Philips
90S & F in repair driver for out door type LED fitting of capacity 40/45 Watt, complete all as specified and directed.
91All as per item No 90 here-in-above but LED driver 60/75 Watt, complete all as specified and directed.
92All as per item No 90 here-in-above but LED driver 90/100 Watt, complete all as specified and directed.
93All as per item No 90 here-in-above but LED driver 120/150 Watt, complete all as specified and directed.
94Supply, install, testing and commissioning of outdoor type cubical panel board, factory made, powder coated, provided with suitable gasket to make it dust/vermin proof for street light control panel.Incomming :-(i) MCCB 63Amp,4 pole 16 KA - 01 No. ( ss incomming) Make: Havell\"s/Legrand/L & T/SiemensOutgoing :-(i) MCCB 63Amp,4 pole 16 KA - 01 No. ( as incomming) Make: Havell\"s/Legrand/L & T/Siemens(ii) One No panel mounted astronomical timer with automatic On/Off through 65 Amp TP contactor and by pass function 63 Amp MCB TP for manual On-Off(iii) Indication lamp for each incoming and ougoing. (iv) Digital voltmeter 0-500 Volt. 01 No. (v) Digital Ammeter 0-100 Amp -01 No.Note: The outer shell shall be made out of 3.15mm thick CRCA sheet powder coatedand suitable size MS angle section frame, factory fabricated with front openable locable/openable by keys at front side.
95M & L for replacement ofsubmain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLSH type, cables 1.5 Sqmm drawn through in and including rigid PVCconduit surface type including 1.5 Sqmm 1100 Volts grade, FRLSH type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals, complete all as specified and directed.Note:- (i)Threeruns of cablesdrawn in conduit shall be measured as one length of sub main. (ii)PVC conduit and its accessories is deemed to be included in this item rates.
96S & F in repair PVC rectangular block for mounting, switches, with PVC sheet cover on top with necessary cutting for mounting switches and fixing accessories for mouting switchescomplete of size 100mm x 100mm and 50mm deep, complete all as specified and directed.
97Supply and fixing in repair of switch piano flush button 5 Amp single pole, one way 230 volts white finish, complete all as specified and directed.
98S & F junction box made from SMC/FRP sheet ready made of size 140 X 140X 95mm with2 way aluminium bus bar of 50 Amp capacity for made in suitablesize fixed inside the junction box with necessary supporting insulators fixed on hylem sheetcomplete, entire assemblyfixed to pole/wall with MS clamp 25 X 5mm and nuts & bolts, or inside the copping of pole/post top with necessary size copper lugs for connecting cables from junction box to fittings, complete all as specified and directed.
99Supply and fixing LED flood light 50 Watt, 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant , with necessary fixing arrangement with MS clamp, with suitable size bolts, nuts, washers completeof fixing arrangement on bulding wall/pole/bulding sunshade PCC block foundations at groundcomplete with driver and lamp, complete all as specified and directed.
100All as per item No 99 here-in-above but LED flood light 100 Watt, complete all as specified and directed.
101All as per item No 99 here-in-above but LED flood light 150 Watt, complete all as specified and directed. Note : An amount of Rs.27122.00 on account of credit schedule for schedule \"A\" part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
102Supply and fixing energy efficient ‘LED Flood Light120 W LED luminairewith Aluminium dia cast housing, toughened glass cover with IP 66 protection, CCT 5700 K including fixing arrangment on wall/pole / surface and connecting cable up to nearest ceilign rose into flexible PVC conduit. Make : Crompton/Havells/ Surya/Philips

AI Tender Summary

OUR REF NO 37740501
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 08-06-2023
Authority
Authority Name Military Engineer Services
Work Description Repair/Maint Of Cooling Appliance And Misc Work, Repair/Maint Of Street Light Including Replacement Of Street Light Panel, Timer, Junction Box And Other Connected Works In Omq Area And Repair/Maint Including Replacement Of Building Security Lights I
Basic Detail
Tender No C/8671/23-24/E8
Bidding Type Tender
Location
City hasimara
State West Bengal
Key Dates
Publish Date 18 May 2023
Submission Date 08 Jun 2023
Open Date 15 Jun 2023
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 72000
Exemption Not Available
Document List
9b2844f2-ee76-424c-8dc3-bd88938dba22.html
BOQ_667926.xls
Tender8671.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 18, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 08, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 15, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

9b2844f2-ee76-424c-8dc3-bd88938dba22.html

xls

BOQ_667926.xls

pdf

Tender8671.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender