Tender For Repairs To Water Profing Treatment Of Roof, Over Tank Cleaning And Pipe Line Cleaning, Sanitary Fitting, Tilling, Plinth Protection To Certain Buildings At Jaffarpore, Kanchrapara And Los Dum Dum Under Ge (Af) Barrackpore, barrackpore-West Bengal

Military Engineer Services-MES has published Tender For Repairs To Water Profing Treatment Of Roof, Over Tank Cleaning And Pipe Line Cleaning, Sanitary Fitting, Tilling, Plinth Protection To Certain Buildings At Jaffarpore, Kanchrapara And Los Dum Dum Under Ge (Af) Barrackpore. Submission Date for this Tender is 08-06-2023. Water Proofing Work Tenders in barrackpore West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

37740406
Tender For Repairs To Water Profing Treatment Of Roof, Over Tank Cleaning And Pipe Line Cleaning, Sanitary Fitting, Tilling, Plinth Protection To Certain Buildings At Jaffarpore, Kanchrapara And Los Dum Dum Under Ge (Af) Barrackpore
Open Tender
Indian
West Bengal
barrackpore
08-06-2023

Tender Details

Repairs To Water Profing Treatment Of Roof, Over Tank Cleaning And Pipe Line Cleaning, Sanitary Fitting, Tilling, Plinth Protection To Certain Buildings At Jaffarpore, Kanchrapara And Los Dum Dum Under Ge ( Af ) Barrackpore

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

BOQ Items

Name of Work: REPAIRS TO WATER PROFING TREATMENT OF ROOF, OVER TANK CLEANING AND PIPE LINE CLEANING, SANITARY FITTING, TILLING, PLINTH PROTECTION TO CERTAIN BUILDINGS AT JAFFARPORE, KANCHRAPARA AND LOS DUM DUM UNDER GE (AF) BARRACKPORE.
Sl. No. Item Description
1Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided including reinforcement cut as required to facilitate demolition and removing debries from site of work complete all as directed.
2Demolition of cement concrete (un-reinforced) in ground floor and pavings n.exc. 15cm thickness (below or above ground level) complete all as specified and directed.
3Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises completeall as specified and directed.
4Taking down cement plaster of any description built in cement mortar on brick or stone walls etc including racking out joints, hacking for key, scrubbingdown with water etc. and removal of rubbish from the site complete all as specified and as directed.
5Material and labour for pre-cast RCC (1:2:4) type B0 (using 12.50 mm graded stone aggregate) in landings, cover slab, chulla hoods, chajjas, water troughs, shelves and similar articles of any thickness and size and set incement mortar (1:4) including necessay formwork complete all as specified and directed.
6Supply only liquid water proofing compound (WPC) completeall as specified and directed.
7Material and labour for mild steel TMT bar 10 mm dia and over cut to length bent to shape required, including cranking, bending spirally for hooping ends and binding with and incl. mild steel wire (annealed) not less than 0.9 mm diaor securing with clips. complete all as specified and directed.
8Material and labour for mild steel TMT bar 6mm to 8mm mm dia and over cut to length bent to shape required, including cranking, bending spirally for hooping ends and binding with and incl. mild steel wire (annealed) not less than 0.9 mm diaor securing with clips. complete all as specified and directed.
9Material and labour for 75mm thick PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection including finishing theconcrete surface even and smooth without using extra cement complete all as specified and directed.
10Material and labour for ceramic, non skid coloured tiles (premium quality) 7 to 8mmthick (square/rectangular) area of each tile exceeding 0.11sqm but not exc. 0.18sqmas in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar (1:6)complete all as specified and directed.
11Material and labour for ceramic, non skid coloured tiles (premium quality) 7 to 8mmthick (square/rectangular) area of each tile exceeding 0.06sqm but not exc. 0.11sqmas in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar (1:6)complete all as specified and directed.
12Material and labour for glazed ceramic tiles of size 300x200x7 mm / 450x350x7mm (premium quality) coloured in vertical surfaces such as riser of steps, skirting, dado and pillar set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10mm thick cement plaster in cement mortar (1:4) completeall as specified and directed.
13Material and labourfor 15mm thick rendering in cement mortar (1:4) on fair faces of brick work and finish the surfacesfair and even as in wall complete all as specified and directed.
14Material and labour for 5mm thick rendering onconcrete surfaces in cement mortar (1:3) andfinish the surfaceseven and smooth without using extra cement as in ceiling complete all as specified anddirected.
15Taking down existing roof treatment includding PCC padding of any description and roughening surface of old roof by picking, sweeping clean and washing down with water to remove dust, etc. including removing debris from site complete all as specified and directed.
16Material and labour for cutting out cracks to V-section in existing roof or terracing, cleaning out wetting, grouted with crack filling epoxy material complete all as specified and as directed.
17Material and labour for 15mm thick screed bed in cement mortor (1:4) on RCC roof slab including water proofing compound @ 200 ml per bag or as per manufacturer instruction and finishing the surface fair and even complete all as specified and as directed. Note : WPC will be measured and paid separately under respective item.
18Material and labour for water proofing treatment to RCC roof surface incl parapet comprising with the following course of treatment/specifications from bottom to top :- (a) Applying cold bituminous primer @ 0.25 liters per sqm confirming to IS 3384-1986 over plastered surfaces of roof incl parapet surfaces. (b) One layer of APP based polymeric membrane of approved manufacturer, 3mm thick, weight not less than 3.50 kgs per sqm, reinforced with non woven polyester fabric (weight not less than 160 gms per sqm). Polymeric membrane shall take to a height of 60 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (c) Applying two coats of aluminum paint @ 0.10 Kg / Sqm per coat on top of APP membrane. Note: (i) Laying of APP based polymeric membrane shall be done by torch on method or as per manufacturers instructions. (ii) A minimum overlap of 100mm and 75mm should be made in the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as manufacturers instructions.
19Material and labour for preparation of new plastered surfaces of ceiling and applying three coat of white wash completeall as specified and directed.
20Materials and labour for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistance primer complete all as specified and as directed.
21Taking up or down 15 mm bore steel tubing and connections, including cleaning for re-fixing or removal from site complete all as specified and directed.
22Refixing only 15 mm dia old steel tubing and connection in new or old position (wall,floor,ceiling etc) complete all as specified anddirected.
23Supply and fix 15 mm GI tubes (medium grade) with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified anddirected.
24Taking up or down 20 mm bore steel tubing and connections, including cleaning for re-fixing or removal from site complete all as specified and directed.
25Refixing only 20 mm dia old steel tubing and connection in new or old position (wall,floor,ceiling etc) complete all as specified anddirected.
26Supply and fix 20 mm GI tubes (medium grade) with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified anddirected.
27Supply and fix in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints etc fixed to walls or laid on floors complete all as specified anddirected.
28Disconnecting existing tanks of capacity exc 250 ltrs and n exc 500 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified anddirected.
29Disconnecting existing tanks of capacity exc 500 ltrs and n exc 1000 ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified anddirected.
30Supply, hoist and fix 500 litre capacity rotational moulded polyethylene water storage tank three layered (cylindrical vertical with closed top) including 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule after dismantling of old unseviciable existing tank complete all as specified and directed.
31Supply, hoist and fix 1000 litre capacity rotational moulded polyethylene water storage tank three layered (cylindrical vertical with closed top) including 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule after dismantling of old unseviciable existing tank complete all as specified and directed.
32Supply and fix in repair 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
33Supply and fix in repair 20mm bore gun metal globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
34Supply and fixin repair top cover of over head PVC water storage tank of any capacity complete all as specified and directed.
35Supply and fix in repair15mm bore stop valves, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
36Supply and fix in repair 15mm bore brass angle valve chromium plated foriron pipe complete all as specified and directed.
37Supply and fix in repair 15mm bore pillar tap cast copper alloy with capstan heads, chromium plated, screwed down, high pressure with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and directed.
38Supply and fix in repair 15mm bore fancy type, chromium plated, bib tap, cast copper alloy with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specified and directed.
39Supply and fix in repairbrass chromium plated shower rose 125 mm size with or without swivel joint complete all as specified and directed.
40Supply and fix in repairPVC connection pipe 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
41Supply and fix in repair 125mm PTMT grating doom with waste hole (minimum weight 40gms) complete all as specified and directed.
42Supply and fix in repair vitreous china white squatting pan of ‘Orissa’ pattern, size 580 x 440mm with integral foot rests including ‘P’ or ‘S’ trap, (excluding flushing cistern and flush pipe), including provn of cement concrete bedding (1:5:10) type E1 (using 20mm graded stone aggregate) complete all as specified and directed
43Supply and fix in repair plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
44Supply and fix in repair health faucet 15 mm dia (ABS chromium plated pipe) pipe including 1.25 mtr long PVC flexible tube and ABS wall hook complete all as specified and direted.
45Supply and fix in repair low level flushing cisternof capacity 10 litre ISI marked complete with inlet ball valve, and handle including bracket, waste pipe complete all as specified and directed.
46Supply and fix in repair vitreous china white wash down water closet pan (pedestal pattern) with ‘P’ or ‘S’ trap, front or back inlet, fixing bolts and making all necessary connections complete as specified and directed.
47Supply and fix in repair vitreous china wash hand basin, white, flat back, size 550x400mm excluding taps, waste pipe, chain & plug and porcelain stopper but with brackets and 32 mm bore waste coupling PTMT (minimum weight 45gms) including cutting for and pinning in ends of brackets complete all as specified and directed.
48Supply and fix in repair looking mirror ofsize 600mm x 450mm x 5mm thick bevelled edge of selected quality glass, decorative type mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers completeall as specified and directed.
49Material and labourfor cleaning and removing all scale and dirt etc.by mechanical means (i.e stage-1 - mechanized de-watering, stage-2 -mechanized sludge removal, stage-3 - high pressure cleaning by pressure jet, stage-4 -scrubbing by mini hand scrubber machine, stage-5 - high pressure cleaning by pressure jet, stage-6 - vacuuming by industrial vacuum cleaner, stage-7 - Anti bacterial spray (hydrogen peroxide), stage-8 - UV-Ray treatment. from tanks and from mouths of circulating pipes etc capacity exc. 250.00 litre and not exc. 500.00 litre complete all as specified and directed. Note:- (i)Any damage occured to the tank during the process of cleaning the tank shall be replaced with new tank by the contractor without any extra cost. (ii) The quoted rate shall include for guarantee of a period of One year from the certified date of cleaning. (iii) All debris and waste material obtained during cleaning of tank shall be disposed at a location decided by Engineer -in- Charge distance exc 0.5 Km but not exc 1.5 km without any extra cost. (iv) The quoted rate shall be also included obtaining signature of user in register duly authenticated by Engineer -in- Charge.
50All as per item No 49.00 above but capacity exc. 500.00 litre and not exc. 1000.00 litre and -ditto-.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy