Tender For Repair Replacement Of External Water Supply Ci Gi Pipe Line Valve And Connected Items Sewage Treatment Plant Pipe Line And Fire Fighting Pipe Line At Hq Gna Gmk Inhs Jvt Nih Comcen 2W Det Ncb Mo Goa And Nad Under Ge Gomantak Vasco, vasco-Goa

Military Engineer Services-MES has published Tender For Repair Replacement Of External Water Supply Ci Gi Pipe Line Valve And Connected Items Sewage Treatment Plant Pipe Line And Fire Fighting Pipe Line At Hq Gna Gmk Inhs Jvt Nih Comcen 2W Det Ncb Mo Goa And Nad Under Ge Gomantak Vasco. Submission Date for this Tender is 05-06-2023. GI Pipe Tenders in vasco Goa. Bidders can get complete Tender details and download the document.




Tender Notice

37740134
Tender For Repair Replacement Of External Water Supply Ci Gi Pipe Line Valve And Connected Items Sewage Treatment Plant Pipe Line And Fire Fighting Pipe Line At Hq Gna Gmk Inhs Jvt Nih Comcen 2W Det Ncb Mo Goa And Nad Under Ge Gomantak Vasco
Open Tender
Indian
Goa
vasco
05-06-2023

Tender Details

Repair Replacement Of External Water Supply Ci Gi Pipe Line Valve And Connected Items Sewage Treatment Plant Pipe Line And Fire Fighting Pipe Line At Hq Gna Gmk Inhs Jvt Nih Comcen 2W Det Ncb Mo Goa And Nad Under Ge Gomantak Vasco

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work : Repair/ Replacement of External Water Supply CI/ GI Pipe Line, Valve & Connected items, Sewage Treatment Plant Pipe Line and Fire Fighting Pipe Line at HQ GNA, GMK, INHS JVT, NIH, COMCEN, 2W Det, NCB, MO Goa and NAD under GE Gomantak Vasco
Sl. No. Item Description
1Supply and laying/fixing of 20 mm dia CPVC pipes SDR 13.5 and plain CPVC SDR 11 fitting on wall/ ceiling or laying in trenches , floor complete all as specified.
2All as per item No 1above but 25 mm dia pipe
3All as per item No 1above but 40 mm dia pipe
4All as per item No 1 above but 50 mm dia pipe
5Supply and laying GI tubings medium grade dia ISI Mark with all fittings such as elbow, bends, sockets, nipples and union etc and fixed complete laid in trench/wallfor the 100 mm dia all as specified and directed by Engr-in-charge .
6All as per item No 5 above butGI tubings medium grade dia 80 mm
7All as per item No 5 above butGI tubings medium grade dia 50 mm
8All as per item No 5 above but GI tubings medium grade dia 40 mm
9All as per item No 5 above butGI tubings medium grade dia 25 mm
10All as per item No 5 above but GI tubings medium grade dia20 mm
11Supply and laying UPVC Pipes (SCH-80)with all fittings such as elbow, bends, sockets, nipples and union etc and fixed complete laid in trench/wallfor the 65` mm dia all as specified and directed by Engr-in-charge.
12All as per item No11 above but 50 mm bore pipe.
13All as per item No11 above but 40 mm bore pipe.
14All as per item No11 above but 20 mm bore pipe.
15Taking up or down steel tubing and connection cleaning/removing blockege including fitting and refixing the same on any position/root etc complete for 20 mm bore of pipes all as spd. And directed by Engr-in- charge.
16All as per item No 15 above but 25 mm bore pipe.
17All as per item No 15 above but40 mm bore pipe.
18All as per item No 15 above but50 mm bore pipe.
19Maintenance of Chamber coverincluding wellding of allbroken hindgesandpaintone coat of redoxide then one coat of existing collour all as specified and directed by Engr-in-charge
20M & L forPainting of any size ofpipe linewith connected items in pump housefrom sump to over head pipe lineas per existing colour (Suction/delivery/washout/overflow pipe line) complete all as specified and directed by Engr-in-charge.
21Supply and laying CI pipes with spigot and socket ends centrifugally cast class LA in any length, laid in treanches for the following sizes including taking down of existing old CI pipe complete all as per specified and directed by Engineer in charge.
22(a) 80 mm bore pipe
23(b) 100 mm bore pipe.
24Excavating in trenches n exe 1.5 m wide and notexceeding 1.5 m in depthgetting out hard/dense soil for laying of GI pipe complete includidng taking down of old GI tubing complete all as directed by Engr-in-charge
25Excavating in trenches n exe 1.5 m wide and notexceeding 1.5m in depth for removing and laying G.I tubing and getting out in soft/disintegrated rock.
26Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil and soft/disintegrated rock.
27Removal of excavated material soil/rock to a distance not exceeding 50 m and depositing where directedby Engr-in-charge.
28Supply and Fixing Gun metal Globe or gate valve with iron wheel head screwed both ends for iron pipe of 20 mm bore sizes complete all as per spd and directed by Engineer-in-charge.Make : Leader, Bajaj
29All as per item No 26 above but 25mm.
30All as per item No 26 abovebut 40 mm.
31All as per item No 26 above but50 mm.
32All as per item No 26 above but65 mm.
33All as per item No 26 above but80 mm.
34Material and labour for heavy duty sluice valve complete with iron wheel conforming to IS 1969 double flanged and drilled endprovided with high tensile steel spindle including GI flanged Bolts/Nuts/washers gasket etc all and removal of old valve of following sizes : Make - Kirloskar/Leader/BIR/Pryag
35(a) 80mm bore
36(b) 100mm dia bore
37( c)150 mm dia bore
38Material and labour for valve pit chamber on existing chamber foundation with 230mm thick brick wall in CM 1:6, 75mm thick coping in PCC 1:2:4 (Type B1), 15mm thick plaster in CM 1:4 over all internal and external wall surface, 25x25x4mm thick MS Angle iron frame and 3.0 mm thick MSplate cover with hinges and necessary locking arrangements painting with two coats of synthetic enamel paint over one coat of red oxide primer all as specified and directed including dismantling and removal of existing damaged chamber except PCC foundation of internal size :-
39(a) 600 x 600 x 600mm
40(b) 900 x 900 x 750mm
41(c) 1000 x1000 x 750mm
42Supply and Fixing15 mm ball floatvalve high pressure of PTMT with expoxy coated alumimium rod and highdensity ball screwed for iron pipe with polythene float and fly nut completewith all accessariess including taking down the old float valve complete all as directed by Engr-in-charge
43All as per item No 34 but 20mm Float valve
44All as per item No 34but 25 mm Float valve
45Material and labour for run lead joint including removal of old joints/joining material, excavation and earth work if any required, etc for cast iron pipe of size including taking out old run lead joint. complete all as specified and directed by Engr-in-charge (Note: Earth work shall be measured and paid sepratelly)
46(a) 80mm dia bore
47(b) 100mm dia bore
48(c) 150mm dia bore
49Material and labour for rubber flanged joint including removal of old joints/joining material, and replacing Nuts and bolts , etc for GI/cast iron pipe of following sizescomplete all as specified and directed by Engr-in-charge including taking out old joint.
50(a) 80mm dia bore
51(b) 100mm dia bore
52Supply and fixing of superior quality suitable gland Packing rope of 8/10/12/12.5/14/16 mm sizes to Sluice Valves of different sizes and capacities including new nuts and bolts complete all as specified and directed.Note:(a) Quoted rate demmed to be inclusive of cost of rope and opening & refixing gland plate of valve/pump,.new nut botls ,packing rubber etc.
53Material and labour for Cleaning of sewage well/tank of any size 07 Nos by(i) Dewatering with submercible / sludge pump to empty the sump/tank upto base level. (ii) Removing sludge from sump wall and bottom with the help of special sludge pump and remaining dirt which may have hidden in rough slots of the bottom mannualy with brush.(iii) After cleaning the sump apply bleaching powder for disinsfection of sump including painting of iron grills of the chabmer cover with black paint all as directed by Engineer-in-Charge: Note Sewage will be collected in sewage vehicle and thrown at sewage disposal area .
54Supply & pouring Bio media (Floating type)made of plastic and Corrugated shapehaving Effective surface area 400Sqm/cum ,PP22 in MBBR as direct by Engineer-in-Charge
55Supply & MixingSodium hypochlorite solution in liquid form for treated STP Water tank complete all as specified and directed by Eng-in-charge.
56M&Lforcleaning and sterilization of insideof Overhead tankby using approved chemical as recommended to use by the Govt and ultra voilet rayincluding arrangement of necessary tools & plants, labouretccomplete all as specified and as directed for following capacitities of overhead tank: stages for cleaningare as under:- (a) Mechanised dewatering of water storage tanks (b) Removal of Sludge lying on the bottom of tank. (c) Cleaning of Internal walls of tank through High pressure Rotary jets. (e) Spray Potassium permanganate Inside the tanks as anti- bacterial agent. (f)UV Radiation in the tank for future cleaning germs.
57(a) 30,000 Gallons (at Gomantak PH/MO Goa)
58(b) 20,000 Gallons (at Gomantak PH/2 W Det PH)
59(c) 10,000 Gallons (at NAD)
60M&Lforcleaning and sterilization of insideof Under groung sumpby using approved chemical as recommended to use by the Govt and ultra voilet rayincluding arrangement of necessary tools & plants, labouretccomplete all as specified and as directed for following capacitities of under groung sump :- stages for cleaningare as under:- (a) Mechanised dewatering of water storage tanks (b) Removal of Sludge lying on the bottom of tank. (c) Cleaning of Internal walls of tank through High pressure Rotary jets. (e) Spray Potassium permanganate Inside the tanks as anti- bacterial agent. (f)UV Radiation in the tank for future cleaning germs.
61(a) 20,000 Gallons (at Gomantak PH/2 W Det PH)
62(b) 15,000 Gallons (MO Goa PH)
63(c) 10,000 Gallons (JVT PH/DSC PH GMK/NIH PH/NAD PH/NCB)
64M & L for conducting bacteriological and chemical analysis at DIRECTOR OF HEALTH SERVICES ENVIROMENTAL AND POLLUTION CONTROL WING. PANAJI, GOANOTE ;-(a) The water sample should be carried out in sterilized bottle/water can which will be issued by DIRECTOR OF HEALTH SERVICES ENVIRONMENTAL AND POLLUTION CONTROL WING, PANAJI, GOA.(b) The rate quoted shall be deemed to include transportation cost & cost of sterilized bottle. (Location: Gomantak/NCB/2W Det/MO Goa/NAD
65M & L forcarrying out following parameters test at NABL accredited lab complete all as specified and direcetd. The parameter are as follows: (a) BOD (b) COD (c) Oil and grease (d) Suspended solids (TSS) (e) pH (f) DO (g) E coli Note:The rate quoted shall be deemed to include transportation cost & cost of items reqd for collection .
66Supply and fix chloroscope meter for water testing range of 0.1 PPM to 2.0 PPM .Make:- M/S Water chem/Good Men/Magic India/ZeroB/Aquasol
67Supply and fix O-TOLODINE reagentsolution in 500 MLbottles of superior quality duly sealed all as directed. Make:-M/s Glaxo/SOS/Water chem/Qualigens
68Supply and fix Gun metal brass foot valve screwed or flanged type complete suitable for the following size of GI tubing including taking down of existing valve.Make : Leader, Bajaj
69(a) 50mm dia bore pipe
70(b) 80mm dia bore pipe
71(c) 100 mm dia bore pipe
72(d) 150 mm dia bore pipe
73Supply & fix long length Cast Iron detachable jointcomplete with nuts , bolts ,washers and superier Quailty of Rubber ring set suitable for following sizes .
74a) 150mm diabore
75b) 100mm diabore
76c)80mm dia bore
77Supply and mixing of Calcium Based Granular Disinfectant For Water Treatment, More Stable Than Chlorine Gas And Stronger Than Bleaching Powder And Sodium Hypochlorite.Concentartion of Chlorine 60 To 70 Percent Stabilty Of One Year With Minimum Loss Of Chlorine in factory sealed non returnable HDPE containers (40 to 50 Kg each) complete all as specified and as directed.
78Supply and fix in repairs non return valve complete all as directed of following sizes:-
79(a) 100 mm dia
80(b) 80 mm dia
81(c)50mm dia
82Supply and fixing automatic air release valve of gun metal of 20mm dia complete all as directed.Note: Rate deemed to be inclusive of drilling boreand other necessary minor items reqd for fixing of Air release valve.
83M & L for emtying the sewage tank (during taking up & during lowering ) ,dismantling and disconnecting ofall electrical connections of non cloge submersible pump of any capacity, taking out from sewage well shifting it to work shop for repairing/rewinding and reassembling ,transporting back to site after repair , lowering it to sewage well , testing and commissioningcomplete all as specifiecd and directed by EIC. .Note (i) Sewage tank will be emptied by sewage vehicle and sewage will be disposed at sewage disposal site and rate is inclusive of that. (ii) All spare parts reqd for repair and rewinding will be measured and paid for seapartely under respective item of schedule.
84Material and labour for, Dismantaling/openingthe burnt motor, (Rotor & stator ) rewinding the motor with super enamelled copper winding as per existinggauge including insulation material cotton tape, varnish, insulation paper, sleeves and dry and baking etc including replacing of bearing,oilingand reassembling complete motor complete all as directedNote : (i) Oil seal,impeller will be measured and paid for separately (ii) The contractor will furnish six months warranty against any kind of defect for the repair carried out after the date of installation (for STP motor/Centrifugal motor)
85M&L Oil seal for non clog submersible pump upto 5HP cap.
86M&L impeller for non clog submersible pump upto 5HP cap.
87M&L for disconnecting the suction and delivery pipe lines, electric and waterconnections of centrifugal motor pump set of capacity and removing it from its position carefully (from sump /floor) and transporting the same to the workshop for carryout necessary repairs and refixing the same in its original position and re-connecting up of water and electric connections including testing and commissioning complete all as specified and directed. Notes:- (i)Expendable stores like cotton waste / cleaning materials, lubricants, gland packing, metal filling, machining and transportation from site to the work shop and back are deemed to be included in unit rate quoted. (ii) Labour element is deemed to be included in unit rate quoted
88M & L for lifting of Submersible pump alongwith pipe and connected items of any capacity from borewell upto depth of15mtr for rewinding/repairing and lowering after repair work and connectingtesting complete all as specified and directed.
89M & L for lifting of Submersible pump incl pipe and connected items of any capacity from deepwell upto depth 150 mtrsfor rewinding/repairing and lowering after repair work connecting ,testingcomplete all as specified and directed.
90M&L for rewinding ofthesubmersible motor with PVC insulated copper conductor winding wire of‘F’ class heavy grade insulation weight and turns to achieve its full efficiency inclduing tying the winding and connecting the coils and brining the connections as that of exisitng one including replacing of bushes/bearing,oil seal,impeller ,shaft ,Gland plate ,Coupler ,oilingand reassembling complete motor for submersible motor upto 30HP complete all as directedNote : (i) bushes,bearing ,impeller,shaft,seal,gland plate,coupler will be measured and paid for separately (ii) Cost of minor spares such as nuts bolts washers etc is deemded to be inclusive in the rate quoted (iii) The contractor will furnish six months warranty against any kind of defect for the repair carried out after the date of installation.
91M & L for impeller for Submersible pump/Centrifugal pump up to 5 HP
92M & L for impeller for Submersible pump/Centrifugal pump above 5 HP upto 10 HP
93M & L for impeller for Submersible pump/Centrifugal pump above 10 HP upto 20 HP
94M & L for Pump shaft for Submersible/Centrifugal pumps.
95M & L for Bush for Motor.
96M & L for NRV for suitable for deepwell submersible pump upto 20 HP Capacity.
97M & L for Star Rubber bush for Pumps.
98M & L for Pump gland plate .
99M & L for Pump motor Coupler.
100Supply and fix ball bearing suitable for up 7.5HPcapacity motors/pumps after removal of old unserviceable bearing and making proper alignment and testing all as specified and directed by Engr-in-Charge Make: SKF/NCB/FAG/NRB/TATA
101Supply and fix Solenoid valve senser of on line booster pump of 1 HP pumpincluding taking down of existingcomplete.Make: As per existing
102Supply and fix flat submersible copper conductor cable 1100 volts grade PVC insulated flexible, PVC sheathed with multistranded copper conductorcutting to required length connecting with necessary end ferrules / water proof joints of following size including removing the existing unserviceable cable complete all as specified and directed of follwing size:- Make :-Finolex/plaza/Havells/Finecab
103(a) 3 Core 4 Sqmm
104(b) 3 Core 6 Sqmm
105Supply and fixingAutomatic Star delta starter with contactor and pnematic timer ,relay range 23-32 Amp ,contactor rating 25 Amps, 3 ph ,415 V, 50 Hz complete all as directed including taking down old .Make BCH India/Havells
106Supply and fixing repairs Automatic Star delta starter with contactor and pnematic timer ,relay range 13-20 Amp ,contactor rating 16 Amps, 3 ph ,415 V, 50 Hz complete all as directed including taking down old .Make BCH India/Havells
107Supply and fix in repairs flange for Pipes including threading ,welding etcof follwing Sizes:-
108(a) 80 mm dia size
109(b) 100 mm diz size
110Supply and fixingDOL Starter suitable for 5 to 7.5 HP Motor ,415V,3 phase ,50Hz ,contactor rating 16 Amp complete all as directed .Make BCH India/Havells
111Supply and fixingDOL Starter suitable for 2 to 5 HP Motor ,415V,3 phase ,50Hz ,contactor rating 16 Amp complete all as directed .Make BCH India/Havells
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail