| 1 | Supply and fixing of 300mm (12\") sweep (light duty) AC exhaust fan complete with necessary wall opening andmaking good of the wall |
| 2 | Brick Partition Walls using II class ground moulded chamber bricks of size 9\"X43/8\"X 23/4\"in C.M 1:3using hoop iron reinforcement,if found necessary standard specification including finishing, curing,etc., complete complying with standard specification - 10 sqm |
| 3 | Plastering with cement mortar (1:5) 12mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306) |
| 4 | Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being \"32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum |
| 5 | Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete |
| 6 | Paving the floor with Vitrified Marbonite tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3(one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Municipal Engineer before use on work |
| 7 | White washing two coats with freshly burnt shell lime white in colour in all floors including cost of lime and other materials brushes scaffolding charges etc.complete complying with standard specification and as directed. -100sq.m S.I.333 |
| 8 | Painting two coats with ready mixed Plastic Emulsion Paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. - 10 sq.m |
| 9 | Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coatincluding the cost all materials etc.,complete, in all floors. |
| 10 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade insuitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with 150mm x 100mm x 75mm MSswitch box inflush with wall with 3mm thick hylum sheet cover for 5A 3pin non interlocking flush type CS plug withpainting of suitable colour with continuous earthwire connection of 14SWG TC wire for open plug point sd 11 |
| 11 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade insuitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with MS switch Box and 5A FT switchwith painting of suitable colour continuous earth wire connection of 14 SWG TC wire for light point / fan point (forelectronic regulator) sd 01 |