Tender For Replacement Of Damaged Electrical And Mechanical Items At Gh 2 Ankur Apartment In Ac 15, Delhi-Delhi

Delhi Jal Board-DJB has published Tender For Replacement Of Damaged Electrical And Mechanical Items At Gh 2 Ankur Apartment In Ac 15. Submission Date for this Tender is 24-05-2023. Forming Tools Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

37722575
Tender For Replacement Of Damaged Electrical And Mechanical Items At Gh 2 Ankur Apartment In Ac 15
Open Tender
Indian
Delhi
Delhi
24-05-2023

Tender Details

Tender For Replacement Of Damaged Electrical And Mechanical Items At Gh 2 Ankur Apartment In Ac 15 - 1. S/o Changeover, Switch, 160 Amp, 4 Pole, 415V AC. Make:- L&T/Schneider/HPL 1 No. 2. S/o Moulded Case Circuit Breaker (MCCB) of rating 160 Amp, Triple Pole, 415V, AC of breaking capacity of 50 KA or more. Make:- L&T/Schneider/BCH/C&S 1 No. 3. S/o Moulded Case Circuit Breaker (MCCB) of rating 100 Amp, Triple pole, 415 V, AC of breaking capacity of 36 KA or more. Make:- L&T/Schneider/BCH/C&S 3 No. 4. S/o Ampere Meter Digital type. Make:-L&T/Schneider/AE 1 No. 5. S/o Volt Meter Digital type. Make:-L&T/Schneider/AE 1 No. 6. S/o Ampere Meter selector switch. Make:-L&T/Schneider/BCH/C&S 1 No. 7. S/o Volt meter selector switch. Make:-L&T/Schneider/BCH/C&S 1 No. 8. S/o Indicating Lamp, Led type Make:-L&T/Schneider/BCH/C&S 9 No. 9. Supply of Manually operated oil immersed sheet steel clad wall mounting star – Delta Starters fitted with 1 No. Under voltage release, 3 Nos. Magnatic Overload Release with Oil Dashpot time lags, stop leaver, plain enteries for PVC cables suitable for Squirrel case induction motor 415 V, 3 Phase, 50 Hz, 41-60 HP Heavy Duty Make: - Advance, Bentax or any approved in DJB 2 Nos. 10. Supply of Oil immersed automatic push button operated sheet steel clay mounting direct on line starter 415 volt 50 Hz, three phase 7.5 HP 1 No. 11. Supply of starter oil make Power / Savita 50 Ltr 12. Dismantling of old panel board accessories / starters etc. and disconnecting all the old incoming and the outgoing connection and fixing of new component in the panel & starter. 01 Job 13. Dismantling of pump sets by disconnecting of power connections from motor, de- coupling of motor and pump , cutting of foundation bolt, dismantling of suction and delivery pipes, / special, closing of valves taking out pump motor and specials from dry sump/ pump house with the help of manual labour and keep it at safe place of pump house. 2 Job 14. Removing of rusted base frame from the RCC foundation by cutting with gas cutter etc. and taking out of complete damage frame with the help of manual labour outside of pump house. 2 Job 15. Breaking of RCC foundation by hydraulic hammer and manual labour to take out old existing foundation bolts and taken out malva. 2 Job 16. Re- casting/ strengthen of RCC foundation, re-grouting foundation bolt, plastering and making wet layer of cement of the foundation i/c.. Shuttering etc. as required. 2 Job 17. Making / fabrication of MS base frame with antirust G.I. coating suitable for pump The base frame should be made MS channel of required/ existing size of channel. I/c vibration Pad, foundation bolt, drilling/ machining and painting as required ( As per sample) 2 Job 18. Supply of nut bolts washers and studs for re-fixing of pump and motor. 25 Kg 19. Supply of neoprene rubber sheet having 50% neoprene, 3 mm thick Make Jyoti/Worth/DJB approved 50 Kg. 20. Fixing of newly fabricated MS foundation base frame on the RCC foundation plastering/ filling the gap of RCC foundation and MS foundation after fixing of base frame with the help of SS nut as required. 02 No. 21. Testing and commissioning of pump set on load and no load i.e cartage, painting etc. as required 02 Job

Key Value

Document Fees
INR 500 /-
EMD
INR 6300.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:Replacement of damaged electrical and mechanical items at GH 2 Ankur Apartment in AC 15
Sl. No. Item Description
1S/o Changeover, Switch, 160 Amp, 4 Pole, 415V AC.Make:-L&T/Schneider/HPL
2S/o Moulded Case Circuit Breaker (MCCB) of rating 160 Amp, Triple Pole, 415V, AC of breaking capacity of 50 KA or more. Make:-L&T/Schneider/BCH/C&S
3S/o Moulded Case Circuit Breaker (MCCB) of rating 100 Amp, Triple pole, 415 V, AC of breaking capacity of 36 KA or more. Make:-L&T/Schneider/BCH/C&S
4S/o Ampere Meter Digital type.Make:-L&T/Schneider/AE
5S/o Volt Meter Digital type. Make:-L&T/Schneider/AE
6S/o Ampere Meter selector switch. Make:-L&T/Schneider/BCH/C&S
7S/o Volt meter selector switch. Make:-L&T/Schneider/BCH/C&S
8S/o Indicating Lamp, Led type Make:-L&T/Schneider/BCH/C&S
9Supply of Manually operated oil immersed sheet steel clad wall mounting star – Delta Starters fitted with 1 No. Under voltage release, 3 Nos. Magnatic Overload Release with Oil Dashpot time lags, stop leaver, plain enteries for PVC cables suitable for Squirrel case induction motor 415 V, 3 Phase, 50 Hz, 41-60 HP Heavy DutyMake: - Advance, Bentax or any approved in DJB
10Supply of Oil immersed automatic push button operated sheet steel clay mounting direct on line starter 415 volt 50 Hz, three phase 7.5 HP
11Supply of starter oil make Power / Savita
12Dismantling of old panel board accessories / starters etc. and disconnecting all the old incoming and the outgoing connection and fixing of new component in the panel & starter.
13Dismantling of pump sets by disconnecting of power connections from motor, de- coupling of motor and pump , cutting of foundation bolt, dismantling of suction and delivery pipes, / special, closing of valves taking out pump motor and specials from dry sump/ pump house with the help of manuallabour and keep it at safe place of pump house.
14Removing of rusted base frame from the RCC foundation by cutting with gas cutter etc. and taking out of complete damage frame with the help of manual labouroutside of pump house.
15Breaking of RCC foundation by hydraulic hammer and manual labour to take out old existing foundation bolts and taken out malva.
16Re- casting/ strengthen of RCC foundation, re-grouting foundation bolt, plastering and making wet layer of cement of the foundation i/c.. Shuttering etc. as required.
17Making / fabrication of MS base frame with antirust G.I. coating suitable for pump The base frame should be made MS channel of required/ existing size of channel. I/c vibration Pad, foundation bolt, drilling/ machining and painting as required ( As per sample)
18Supply of nut bolts washers and studs for re-fixing of pump and motor.
19Supply of neoprene rubber sheet having 50% neoprene, 3 mm thick Make Jyoti/Worth/DJB approved
20Fixing of newly fabricated MS foundation base frame on the RCC foundation plastering/ filling the gap of RCC foundation and MS foundation after fixing of base frame with the help of SS nut as required.
21Testing and commissioning of pump set on load and no load i.e cartage, painting etc. as required