| 1 | Taking up Ductile iron / Cast iron/MS pipe water mains (including all fittings), with spigot and socket ends and tyton joints/lead joints including burning out joints and recovering lead for the following sizes complete all as specified and directed. |
| 2 | (a) 80mm bore |
| 3 | (b)100 mmbore |
| 4 | (c)150 mm bore |
| 5 | Supply and lay in trenches in replacement of Ductile iron pipes K-7/K-9 Spigot and Socketed ends, centrifugally cast suitable for tyton joint in different lengths including rubber tyton joint complete as per site condition of following sizes all as specified and directed. |
| 6 | (a)80 mm borek-7 |
| 7 | (b) 100 mm bore k-7 |
| 8 | (c) 150 mm bore k-7 |
| 9 | (d) 150 mm Bore K-9 |
| 10 | Re-laying, jointing old CI/DI/MS pipe dia 80/100/150 mm after cleaning and connections in new or old position including transportation, Flange, lead joint and laid in trenches or on floors complete all as specified and as directed. (excavation & earth work shall be measured and paid separetly) |
| 11 | Supply and laying, jointing and testing MS Pipe heavy grade (class \"C\") including supply and fixing of all fittings such as bend, tee, elbow, union, reducer,flange etc, laid in trenches or wall/ceiling/floor as specified and as directed at site of the following sizes :- (Notes : (i)The laying and jointing of pipes are required to be carried out in short streches catering to specific requirements of a purticular quarter, building block or a group of blocks.) |
| 12 | a) 80 mm bore |
| 13 | b) 100 mm bore |
| 14 | b) 150 mm bore |
| 15 | Supply and fix in replacement of rubber gasket joint tyton joint complete all as specified and directed of the following bore of pipes:- |
| 16 | (a) 80 mm bore |
| 17 | (b) 100 mm bore |
| 18 | (c) 150 mm bore |
| 19 | Supply & Fix / lowering of Power driven Submersible pump set of capacity 15 HP suitable for 60 mtr head 1000 LPM, water cooling type complete with elctric motor of suitable sizeall as per manufacturer’s design including Supply & Making all fixing arrangement as per site requirement like NRV, reducer and flange of suitable size and making electrical connection with jointing material complete all as specified and directed. Make :-KSB item code BPD 273/08, or equivalent makes as approved by GE. Note:-The rate quoted in inclusive of removing unserviceable submerable pump set and depocit in E/M store yard. |
| 20 | M&L for bends (any type, radius, and angle) tapers any type straight bend, increasing, decreasing or double socket Etc) Tee pieces single branch, Y junction, double branch cross 9all socket or socket and spigot) collars, cops, upto 150 mm bore of pipe complete all as specified and directed. |
| 21 | M & L in replacement of tail pieces, flange and plugs or dummy flange plate, connecting pieces one and other socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth complete all as directed of size upto 150 mm bore. |
| 22 | M & L for \"D\" joints complete with nut bolt & washers etc suitable for the following sizes of water mains |
| 23 | a) 80mm bore |
| 24 | b) 100mm bore |
| 25 | c) 150mm bore |
| 26 | Labour only for cutting of cast iron water mains of following sizes carefully in repairs for inserting fittings such as bend, tee, socket pieces, collar etc complete all as specified and as directed. |
| 27 | a) 80mm bore |
| 28 | b)100mm bore |
| 29 | c)150mm bore |
| 30 | M&L for drilling / boring and tapping cast iron water mains (in position) for branch connections of the internal dia 20 mm complete all as specified and as directed. |
| 31 | M&L for Straight plain brass ferrules (or connecting screws ) screwed both ends and fixed to CI pipes pipes of size 20 mm bore complete all as specified and as directed. |
| 32 | Supply & Fix gun metal gate valve with iron wheel head screwed both end for iron pipe complete all as specified of the following sizes including dismantling the old unserviceable existing valve complete all as specified and as directed. |
| 33 | a) 15mm bore |
| 34 | b) 20 mm bore |
| 35 | c) 25 mm bore |
| 36 | d) 40 mm bore |
| 37 | e) 50 mm bore |
| 38 | Taking out unserviceable sluice valve including S & F sluice valve, class PN-1, heavy duty, both ends flangedwith gun metal spindle & check nut and all nuts, bolts, washers, gaskets etc; including dismantling of old unserviceable sluice valve complete of the following sizes (Note :- for these sluice valves which are fixed with pillar of over head tank work involve such as breaking of PCC/Lead flange joints will be deemed to include in the rate quoted & contractor will also repair the damaged floor etc,to match with existing. ( joints shall be measured & paid for seprately) Make: Zoloto CodeNo-84813000, equivalentL&T / Kalpana / Kirloskar / BIR / Leader |
| 39 | a)80 mm bore |
| 40 | b) 100 mm bore |
| 41 | c) 150 mm bore |
| 42 | d) 200 mm bore |
| 43 | Taking out unserviceable Non return valve supply andfixing connecting and testing non return valve horizental flow both and flanged class \"B\" as per IS specification and conforming to IS -5312 including flange joints etc for the following sizes Make : Zoloto CodeNo-84813000, or equivalent Kalpana / BIR / Kirlosker / Leader |
| 44 | a)80 mm bore |
| 45 | b)100 mm bore |
| 46 | Excavation in trenches not exc. 1.5mtr wide and not exe 1.5 mtr in depth forlaying GI pipe/ CI Pipe etc. and getting out in soft/loose soil complete all as specified and directed. |
| 47 | Returning fillingin soil from excavation including spreading, leveling, watering and well ramming in layers n.exe. 25 cm thickcomplete all as specified and directed. |
| 48 | Removing excavated (surplus soil) to a distance not exc. 50 m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 49 | M&L for construction of brick masonry valve chamber of internal size 1.05 Mtr x 1.05Mtr x 1.05 Mtr (Internal dimension) with sub class \"B\" bricks in CM (1:6) and plaster with 15mm thick in Cement mortar 1:4 and painted with three coats of white wash on exposed plaster surfaces and covered wuth3mm thick MS Sheet cover and angle iron frame made out of 40mm x40mmx6mm with 2 Nos MS hinges welded to angle iron frame including lifting hook & locking arrangement duly painted with one coat of black bituminous paint over a coat of red oxide primer complete includingnecessary earth work, brick work, PCC bed, cement plastering, finishing including dismantling and removal of old unserviceble valve pit remains from site complete all as specified and directed. |
| 50 | all as per item no 19 but for 900 mm x 900 mm x 900 mm (Internal dimension) |
| 51 | all as per item no 19 but for 650 mm x 650 mm x 650 mm (Internal dimension) |
| 52 | Cutting of road/dismantling of any interlocking paver blocks from pathways making good after laying of cable / pipe lines as in original position including replacement of disturbed paver blockscomplete all as specified and directed. |
| 53 | M&L for PCC 1:2:4 type B1 using 20 mm stone aggregate for providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string course lacing courses, parapets and railing upto 60cm in height copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded orchamfered angles and throating complete all as directed |
| 54 | M&L for brickwork with subclass ‘B’ bricks, built in cement mortar 1:4 straight or curved on plan exc 6m mean radiuscomplete all as specified and directed |
| 55 | M&L for rendering 10 mm thick on fair face of brick work in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed. |
| 56 | S&F bib taps 15 mm bore, Bib taps, cast iron with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed. |
| 57 | S&F bib taps 20 mm bore, Bib taps, cast iron with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed. |
| 58 | S&F rubber insulation safety mat class C suitablefor pump house all as specified and directed. |
| 59 | M&L painting cast iron/MS water mains external surfaces with one coat of synthetic paint over existing painted surfaces including preparation of surface of rising mainfor the following completed allas specified and directed. |
| 60 | (a) 150 mm bore |
| 61 | (b) 100 mm bore |
| 62 | (c) 80 mm bore |
| 63 | Taking out, sluice valve top cover, spindle and broken / unsv check nut (gutka)carry to workshop & re-fixing ofsluice valve after servicing /maintenance /grinding / cleaning / threading / greasingwork to sluice valve parts, including replacement of gland packing, rubber sheet, nut, bolt, Spindle ,check nut and washer of existing size complete all as specified and directed, of following size:- |
| 64 | (a) 80 mm dia bore |
| 65 | (b) 100 mm dia bore |
| 66 | (c) 150 mm dia bore |
| 67 | (d) 200 mm dia bore |
| 68 | S&F PU PVC tube for chemical dosing supply of outer dia 8 mm and internal dia 6 mm including taking out old broken PU tube all as specified and as directed |
| 69 | S&F 3- layer PP-R (Polypropylene random copo-lymer)conceal-ed pipes SDR 7.4 (PN16) UV stabi-lized and antimi-crobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene including taking out and all fittings laid in trenches/wall/floors in following size. |
| 70 | (a) 16 mm dia bore |
| 71 | (b) 20 mm dia bore |
| 72 | (c) 25 mm dia bore. |
| 73 | (d) 50 mm dia bore |
| 74 | (e) 75 mm dia bore |
| 75 | Supply and replacement of nylon rope heavy duty 40mm dia for suction sweeper complete all as specified and directed. |
| 76 | Supply, installation, testing & commissioning in replacemnt, Granular chlorination Dosing pump (MODEL 96 NGQ 51), high pressure, single head, gear motored adjustable dosing pump having output of 2 U.S. GPD to 40 U.S. GPD and adjustable high pressure of up to 100 PS I (7.00 Kg/Sqcm) with accessories including lead, tubing, connections, nuts, injection check valve, clay weight and ferrules also including 100 litre FRP tank with lid & Level gauge along with Agitator and shaft & blade in plastic mounted on tank.The agitator motor shall have capacity of voltage input 230V, Single phase, 50HZ, 900 RMP 100 watt complete all as specified and directed. Make: Declibac Technologies or equivalent |
| 77 | M&L for repair of unserviceable submersible pump 3 Phase 415 Volts AC 50Hz, 30 HP, 102 M3 / Hr (1700 to 2000 LPM) at 65 mtr head and discharge suitable for 150 mm dia column pipe, taking out from existing bore well and transportaion to civil work shop for repair including lathe machine work and replacment of unserviceable spare parts such as head, shaft, upper bearing, replacement of casing, impeller, diffuser, lower bearing, stainer, sleeves, gun metal bush and also including rewinding of motor with stove enamelled copper wire as per existing size, connecting column pipe, nuts bolts & washers, rubber gasket, bore cap and electric connection complete all as directed. |
| 78 | M&L for dismantling existing dozing pump mounted on FRP / PVC tank of any capacity & type including S&F Granular chlorination Dosing pump, high pressure, single head, gear motored adjustable dosing pump having output of 2 U.S. GPD to 40 U.S. GPD and adjustable high pressure of up to 100 PS I (7.00Kg/Sqcm) with accessories including lead, tubing, connection nuts, injection check valve, clay weight and ferrules Make: Decliback MODEL 96 NGQ 51 or equivalent of Ramco |
| 79 | S&F in replacemnt, 100 liters FRP tank with lid (cover) &verticallymarked Level Scaleto checklevel of solution inside the tank suitable to existing system complete all as specified and directed. Make: Ramco/ Declibeck |
| 80 | S&F in replacement, Agitator motor having capacity of voltage input 230V, Single phase, 50HZ, 900 RMP 100 watt suitable for existing system complete all as specified and directed. Make: Ramco/ Declibeck |
| 81 | S&F in replacemnt, Agitator and its shaft & blade in plastic mounted on tank including its related accessories suitable or match with existing assembly complete all as specified and directed. |
| 82 | Supply only PVC flexible pipe (Suction pipe)2\"\" dia as per site requirement all as specified and directed. |
| 83 | S&F in replacement of PVC NRV for chamical doging pump as per site requirement all as specified and directed. |
| 84 | Supply & Making column pipe with Mild steel cold ERW column pipe 80 mm bore, 10 feet long, 7.20 mm wall thick and threading upto 80 mm from end including supply & fix / welded 10 mm thick mild steel flanged both ends duly drilled for fixing 04 Nos nut bolts & washers and fixing nut bolt of size75 long & 12mm dia with 02 nos washer and suitable size of rubber gasket, including welding of three Nos 150 mm long 40x6 mm flat iron pieces one side with flanged and other side with column pipe complete all as specified and directed |
| 85 | Taking out steel tubing from from trenches/or from any site all as directed by Engineer-in-Charge for the following sizes complete all as specified and directed (excavation & earth work shall be measured and paid separetly) |
| 86 | a)15mm bore |
| 87 | b)20 mm bore |
| 88 | c)25 mm bore |
| 89 | d)40 mm bore |
| 90 | e)50 mm bore |
| 91 | f)80 mm bore |
| 92 | Supply and laying, jointing and testing GI Pipe medium grade including supply and fixing of all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches or wall/ceiling/floor as specified and as directed at site of the following sizes :-(Notes : (i)The laying and jointing of pipes are required to be carried out in short streches catering to specific requirements of a purticular quarter, building block or a group of blocks.) |
| 93 | a)15mm bore |
| 94 | b)20 mm bore |
| 95 | c)25 mm bore |
| 96 | d)40 mm bore |
| 97 | e)50 mm bore |
| 98 | f)80 mm bore |
| 99 | Re-laying, jointing old steel tubing after cleaning and connections in new or old position including supply & Fix new fittings such as bends, elbows, union, tees, reducers etc; as required at site laid in trenches or on floors complete all as specified and as directed of the following sizes :- |
| 100 | a) 15mm bore |
| 101 | b)20 mm bore |
| 102 | c)25 mm bore |
| 103 | d)40 mm bore |
| 104 | e)50 mm bore |
| 105 | f) 80 mm bore |
| 106 | Supply and fixing Ball valves high pressure of PTMT with epoxy coated Aluminiumrod& highdensity plastic ball screwed for iron pipe and fixed complete all as specified and directed. |
| 107 | 20 mm dia bore |
| 108 | 25 mm dia bore |
| 109 | Supply & installed Star Delta Starter( fully automatic star delta) Complete with Power Contactor\"s, Relay, Timer in Factory built Sheet Metal enclosure suitable for 17.5 HP Submersiblepump.Make L&T Cat part No SS94362 or equivalent make of Schneider/Havells/Indo Asian. |
| 110 | Supply & installed Star Delta Starter( fully automatic star delta) Complete with Power Contactor\"s, Relay, Timer in Factory built Sheet Metal enclosure suitable for 7.5 HP /10 HP Submersiblepump.Make L&T Cat part No SS94362 or equivalent make of Schneider/Havells/Indo Asian. |