Tender For Providing Installation Of Flood Light Including Necessary Electrical Wiring In Three Nos Of Tennis Court At Ddssc Badharghat Agartala
Tender Value
15.11 Lakhs
Estimated cost
Bid Submission
31 May 2023
0 days left
EMD
30234
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
badharghat → Tripura
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Providing Installation Of Flood Light Including Necessary Electrical Wiring In Three Nos Of Tennis Court At Ddssc Badharghat Agartala
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 2 | Providing structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete asrequired. |
| 3 | Supplying and filling in plinth, under floor, foundations etc.with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 4 | Reinforcement for R.C.C. work including straightening,cutting, bending,placing in position and binding all complete above plinth level. |
| 5 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 6 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering,shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size):- |
| 7 | Centering shuttering including struttings, propping etc.and removal of form work for: Foundations, footings, bases for columns etc. for mass concrete with timber plank:- |
| 8 | 6 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete. In cement mortar 1 : 4 ( 1 cement : 4 fine sand ):- |
| 9 | Neat cement punning:- |
| 10 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required |
| 11 | 3 core 4 Sq mm |
| 12 | 4 core 4 Sq mm |
| 13 | 4 core 10 Sq mm |
| 14 | Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per dirrection of Site Engineer :- |
| 15 | Drawing of armoured/un-armoured cable with proper saddling etc as required:- |
| 16 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connectionas required. |
| 17 | 4 way SPN MCB DB (single door):- |
| 18 | Supplying and installation of powder coated steel sheet enclosure for 415 volts MCCB (TP/FP) complete with necessary connection etc as required |
| 19 | Enclosure suitable for MCCB upto 100 amps:- |
| 20 | Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):- |
| 21 | 16 to 100 amps FP MCCB, Breakingcapacity 16/18KA (Thermal Magnetic):- |
| 22 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connectionas required:- |
| 23 | 6 to 32 amps SP MCB:- |
| 24 | 6 to 32 amps DP MCB:- |
| 25 | 6 to 32 amps TP MCB:- |
| 26 | 6 to 32 amps FP MCB:- |
| 27 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\"x 12\" having locking arrangement including CC work, holes on earth pipe etc. as required. |
| 28 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. |
| 29 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required. |
| 30 | Supplying and fixing of the following PVC conduit (medium gauge) with all accessories on slab/recessed on wall etc as required. |
| 31 | 19/20 mm dia |
| 32 | 25 mmdia |
| 33 | Supplying, installation, testing, commissining of totally enclosed, weather proof pedestal mounting cubical type, feeder distribution pillar box(of size H=1m,W=0.8m, B=0.6) fabricated out of 2mm thick M.S sheet with vertical & horizontal members of 35mm x 35mm x 6mm angle iron work. Hinged detachable but lockable front door, to be mounted on block masonary/cement concrete pedestal foundation, including mounting the control gears on MS flat with porcelin base support, making connection/inter connections with single core sheeved solid/strip conductor of suitable cross section, paInting lettering earthing etc & fixing in thye wall by MS frame (suitable size) complete as reqd as per direction of site engineer in charge- |
| 34 | Supplying and erection of 10 mtr long G.I pole (medium gauge) 3.6 mm thick, 65 mm top dia (2mtr), 80 mm middle dia (3 mtr) and 100 mm bottom dia (5 mtr) in/c double coat weather proof painting and base plate dimension 300 x 300 x 10 mm with foundation bolts 4 x 24 mm dia, PCD 200 mm, Bolt lenght 750 mm and templete etc. with PVC junction box (185 x 165 x 60) mm in/c necessary connection etc. as required |
| 35 | Supplying and fixing of 300W Floodlight luminaire, IP66 i/c necessary connection as required as per CAT No. :LF20-392-060-57 of Wipro make or similar specification ofHavells / Crompton/PHILIPS make. |
| 36 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- |
| 37 | 1 X 1.5 sq mm |
| 38 | 2 X 4 sq mm |
| 39 | Supplying and laying of following sizes XLPE insulatedPVC sheathed copper conductor Un-armoured cableincluding necessary connection etc as required. |
| 40 | 3 core 1.5 Sq mm |
| 41 | 3 core 2.5 Sq mm |
AI Tender Summary
Tender Timeline
May 16, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedMay 31, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMay 31, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender