Tender For Acoustic Work, Catwalk Work, Fire Fighting Work,Hvac Work, Electric Work,Auditorium Chairs, Stage Lighting System, Step Lighting System, Stage Furnishing System Of Auditorium Building At Eravati Social Science Park At Sppu.(Third Call), pune-Maharashtra

University Of Pune-UOP has published Tender For Acoustic Work, Catwalk Work, Fire Fighting Work,Hvac Work, Electric Work,Auditorium Chairs, Stage Lighting System, Step Lighting System, Stage Furnishing System Of Auditorium Building At Eravati Social Science Park At Sppu.(Third Call). Submission Date for this Tender is 24-05-2023. Electrification Work Tenders in pune Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

37683894
Corrigendum : Tender For Acoustic Work, Catwalk Work, Fire Fighting Work,Hvac Work, Electric Work,Auditorium Chairs, Stage Lighting System, Step Lighting System, Stage Furnishing System Of Auditorium Building At Eravati Social Science Park At Sppu.(Third Call)
Open Tender
Indian
Maharashtra
pune
24-05-2023

Tender Details

Acoustic Work, Catwalk Work, Fire Fighting Work, Hvac Work, Electric Work, Auditorium Chairs, Stage Lighting System, Step Lighting System, Stage Furnishing System Of Auditorium Building At Eravati Social Science Park At Sppu. ( Third Call )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-May-2023 Corrigendum I Date 24-05-2023

Key Value

Document Fees
INR 10000 /-
EMD
INR 460000.0 /-
Tender Value
INR 4.59 Crore /-

BOQ Items

Name of Work: Acoustic work, Catwalk work, fire Fighting work,HVAC work, Electric work,Auditorium Chairs, Stage Lighting System, Step lighting System, stage Furnishing system of Auditorium Building at Eravati Social Science Park at SPPU.(Third Call)
Sl. No. Item Description
1(A) Acoustical - Interior Work(All Wood & Plywood Items should have proper Anti Termite treatment befor fixing)Providing & Fixing in position Acoustical Panelling made fromAbsound Fibril Wood- Wool Acoustic panel 20 mm thick on 50mm x 50 mm2nd class Teak -Wood frame at 600mm x 600mm c/c (center to center)distantce having wooden supports from wall of required length in front of 1000 gsm synthetic wool 50 mm thick with chicken mesh jali of 24 gauge on wall side including cost of required Cut-Outsas per detailed Architectural - AcousticalDesign & Drawings including necessary sacffolding etc. Complete in all aspects. Specification No: As directed byengineer in charge (Excluding cost of2nd class Teak Wood- frame)
2Providing & Fixing in positionTeak -Wood frame 50mm x 50 mm thick or as per required dimentions, at 600mm x 600mmc/c (center to center) or as per required distance having "T" Shape wooden supports from wall of required length & thickness as per detailed Architectural - AcousticalDesign & Drawingsincluding necessary sacffolding etc. Complete in all aspects. The wood members to be treated with antitermite solution before installation. Specification No: As directed byengineer in charge
3Providing & Fixing in position Acoustical Panelling made fromGypsum12mm thick panels on 50mm 2nd classTeak -Wood frame at 600mm x 600mm c/c (center to center)distantce having wooden supports from wall of required length in front of 1000 gsm synthetic wool 50 mm thick with chicken mesh jali of 24 gauge on wall side including cost of required Cut-Outsas per detailed Architectural - AcousticalDesign & Drawingsincluding necessary sacffolding etc. Complete in all aspects. Specification No: As directed byengineer in charge (Excluding cost of 2nd class Teak Wood- frame))
4Providing & Fixing in position Acoustical Panelling of Absound slated wooden acoustic panel width 128 mm, thickness of 16mm and length 2440 mm made of a high density particle board substrate with a laminated facing as per the approved shade /Species & Finish and a melamine balancing layer on the reverse side, with a special perforation pattern fluted perforation on the visible surface with a minimum sag resistance of RH90 and a fire rating class of 1 as per Part 7 of BS 476 with a “tongue-and-grooved” edges and the back of the perforated panel is with sound absorbing non-woven acoustical fleece fixed over ply strip. The ply strip to be fixed over existing 50mm x 50 mm2nd class Teak -Wood frame at 600mm x 600mm c/c (center to center)distantce having wooden supports from wall of required length in front of 1000 gsm synthetic wool 50 mm thick with chicken mesh jali of 24 gauge on wall side including cost of required Cut-Outsas per detailed Architectural - AcousticalDesign & Drawingsincluding necessary sacffolding etc. Complete in all aspects. Specification No: As directed byengineer in charge (Excluding cost of2nd class Teak Wood- frame)
5Providing & Fixing in position Acoustical Panelling made fromWater proof Ply Wood 12mm thick and veneer 4mm or on 50mm x 50 mm 2nd class Teak -Wood frame at 600mm x 600mm c/c (center to center)distantce having wooden supports from wall of required length in front of 1000 gsm synthetic wool 50 mm thick with chicken mesh jali of 24 gauge on wall sideas per detailed Architectural - Acoustical Design & Drawingsincluding necessary sacffolding etc. Complete in all aspects. Specification No: As directed byengineer in charge (Excluding cost of2nd class Teak Wood- frame) (Basic Rates of Veneer Rs 1750.00/ sq.m)
6Providing & Fixing in position, Decorative Fabric wrapped around Techno 10mm thick Compressed Polyester fibre pads panels fixed to wood wool using adhesive,including necessary sacffolding and cost of required Cut-Outs , as per detailed Architectural - AcousticalDesign & Drawings etc. Complete in all aspects. Specification No: As directed byengineer in charge (Basic Rate of Fabric Rs 450.00/sq.m)
7Providing & Fixing in position,Pelmet in "L" shape made from 12mm thick Plywood of size 150 x 150 mmas per Architectural & Acoustical Design & Drawings,including necessary sacffolding etc. Complete in all aspects. Specification No: As directed byengineer in charge
8Providing and Fixing 12mm thick laminated wooden finish perforated tiled false ceilingof approved shade of size 595 x 595 mmwith overlay of synthetic wool 50mm thick 1000 gsm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size (24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying12mm thick laminated wooden finish perforated tiles of approved shade in the grid. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights,as per specifications, drawings,necessary sacffolding and as directed by Engineer-in-Charge. Spec. No.: As directed by Engineer in charge.
9Providing and fixing frame work of galvanised iron for suspended false ceiling which includes galvanised iron perimeter channels of size 27 mm & 0.5 mm thick having one flange of 20 mm and another of 30 mm along with perimeter of the ceiling, fixing in brick wall / partition with the help of rawal plugs and screws, suspending galvenised iron intermediate channels of size 45 mm and 0.9 mm thick with two flanges of 15 mm each from the soffit at 1200 mm centers with steel galvanised iron hanger of width 25 mm x 0.5 mm fasteners, ceiling section of 0.5 mm thickness having curved wedge of 51.5 mm and two flanges of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with the help of connecting clips and in direction perpendicular to the intermediate channel at 450 mm or 300mm centers, 12.5 mm dry walls screws at 230 mmcenters; fixing screws mechanically either with screw driver or drilling machine with suitable attachmentincluding necessary sacffolding etc. complete. Spec. No.: As directed by Engineer in charge
10Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts, necessary sacffolding etc. all complete. Spec. No.: As directed by Engineer in charge.
11Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards with overlay of 50mm thick overlay of 1000 gsm synthetic wool, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lift,including necessary sacffoldings etc. all complete. Spec. No.: As directed by Engineer in charge.
12Providing and Fixing Absound Soft Fibre Acoustical Suspended Ceiling System with Optra (Bevelled Tegular) Edge Tiles of size 15mm Exposed Grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance ?85%, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm, suitable for Green Building application, with Recycled content of 66% GW and 74% RW. The tile shall be laid on precoated G.I channel 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7 Kgs/M2 with a minimum pull out strength of 100 kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system The Tile and Grid system used together should carry a 10 year warrantyincluding necessary sacffolding. As directed by Engineer in charge.
13Providing & Fixing in position Acoustical Doors along with 140 x 90 mm teak wood door frame, doors leafs made from 50mm Teak wood frame 600 x600 c to c filled with 800 Gsm synthetic wool 50mm thick and 5mm Tecsound , 12mm waterproof ply & 4mm thick veneer from both sides , including 100mm heavy duty SS hinges (Geze / Dorma or eq.)4 no each leaf,with Door-closers (Dorma / Geze or eq.) including cost ofdecorative mouldings / finishing-items / melamine polishas per detailed Architectural - AcousticalDesign & Drawings etc. Complete in all aspects. Specification No: As directed byengineer in charge
14Providing and fixing Teak wood planking 25 mm thick for flooring plained on both sides, tongued and grooved , and one coat of primerincluding necessary sacffolding etc. complete. Spec.As directed byengineer in charge
15Providing & Fixing in position 18mm thick Waterproof plywood on50mm x 50 mm Indian Teak -Wood frame at 600mm x 600mm c/c (center to center)distantce including cost of required Cut-Outsas per detailed Architectural -AcousticalDesign & Drawings etc. Complete in all aspectsincluding necessary sacffolding. Specification No: As directed byengineer in charge (Excluding cost of 2nd class Indian Teak Wood- frame)
16Providing and applying water based Polyurethane polish of required finish to the wood work by spray machine including knotting and preparing the evensurface by scraping, applying French polishing etc. complete. Spec: As directed byengineer in charge
17Providing & Fixing in position, Nexgen Carpetmore than 850 gsm, made with100% stain proof synthetic fibres of approved make along with 5mm underlay as per Architectural & Acoustical Design & Instructions & Complete in all aspects.Specification No: As directed byengineer in charge. (Basic Rates of Carpet Rs 1250.00/ sq.m)
18Providing & Fixing in position Under Deck insulation for roof using 800 Gsm synthetic wool with Laminated Tissue paper fixed to roof using adhesive & binding wire as per detailedArchitectural - AcousticalDesign & Drawings etc. Complete in all aspects. Specification No: As directed byengineer in charge.
19Providing and fixing CCTW beading of size 40 mm x 20 mm to the door frame including chamfering finishing with 3 coats of oil painting etc. complete,as per detailed Architectural - AcousticalDesign. Specification No: As directed byengineer in charge.
20Providing & Fixing Teak wood moulding 1 " x 1/2" in position,as per detailedArchitectural - AcousticalDesign & Drawings etc. Complete in all aspects.Specification No: As directed byengineer in charge.
21Providing & Fixing in position Acoustical Partition made from Water proof Ply Wood 12mm thick and veneer 4mm from both sides of frame on 50mm x 50 mmTeak -Wood frame at 600mm x 600mm c/c (center to center)distantce sandwich 800 gsm synthetic wool 50 mm thick including cost of required Cut-Outs as per detailed Architectural - AcousticalDesign & Drawings etc. Complete in all aspectsincluding necessary sacffolding. Specification No: As directed byengineer in charge (Excluding cost of2nd class Teak Wood frame )
22Providing and applying acrylic emulsion paint of approved colour and shade to the existing plaster surface including , preparing the surface with rubbing with flint papers, finishing the undulations with POP putty, applying the acrylic wall puttiincluding necessary sacffolding etc. complete. As directed by Engineer in charge.
23Providing and fixing solid core Flush door shutter in single leaf 32 mm thick decorative type of exterior grade of approved face veneers 4 mm thick on both faces or as directed, including all necessary beads, mouldings and lipping, S.S.hinges, chromium plated fixtures and fastenings,handles on both sides finishing with Melamine Polish as per detailed Architectural Disign & Drawings etc. Complete in all aspects. Specification No: As directed byengineer in charge
24Providing & Fixing in position Podium size of 600mm X 600mm X 1275mmheight with specifications, table top, side and bottom 18 mm thick plylwood with fomica laminated sheeet and C.C.T.W. battens 25mm X 12 mm moulding, including all leads and lifts etc. complete as per drawing. Spec.: As directed by Engineer-In- Charge.
25Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. for catwalk work including scaffolding
26Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. : As directed by Engineer-in-chargefor catwalk work including scaffolding
27(B)Fire Fighting system SUB HEAD - I - (WET RISER SYSTEM - PUMPING EQUIPMENTS) Supply, Installation, Testing and Commissioning of Electric Driven Main Fire Pump suitable for auto operation & consisting of following: complete in all respect as required. 1)Horizontal End suction pump, centrifugal, single stage pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq. cm. at highest and farthest outlet at specified flow of 2280 lpm at 56 mtr.head confirming to IS 1520.2) Suitable HPsquirrel cage induction motor, TEFC synchronous speed 2900 RPM (with permissible slip), suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class- "F" insulation, confirming to IS-325. 3) Common base frame fabricated out of M.S channel of suitable size, flexible coupling, coupling guard, foundation bolts and pressure gauge with valve etc. Suitable cement concrete foundation duly plastered, with anti vibration pads etc. complete as per manufacturer"s design & standards and as per detailed specifications. Suitable HP Spec. : As directed by Engineer-in-charge
28Supply, Installation, Testing and Commissioning of Diesel Engine Driven Main Fire Pump suitable for auto operation and consisting of following: complete in all respect as required.A)Horizontal end suction type, centrifugal, single stage pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet at specified flow of 2280 lpm at 60 mtr.head confirming to IS 1520. B) Suitable HP 1500/1800 RPM, 4 stroke, cold starting type Diesel Engine with Heat Exchanger confirming to relevant BIS & IS Standards, complete with all required accessories / system, fuel oil filter, lubricant oil pump with filter, 2 Nos. starting batteries of 180 AH capacity each with suitable angle iron stand, engine starting panel having all the controls meters, gauges, tachometer, hour meters, starting switch with keys for manual starting, auto starting mechanism, 24 Volts electric starting equipment, Diesel Tank for 8 hrs continuous running of diesel engine, having minimum capacity of 200 Ltrs. (tank made out of 3mm thick M.S. Sheet with filling Cap, drain Cock, diesel indicator duly mounted on M.S. angle) exhaust pipe of minimum 30 Metre length, duly insulated with 50 mm. thick glass wool with 1.0 mm. thick aluminium sheet cladding, exhaust residential silencer, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.C) M.S. fabricated Common base frame, flexible coupling, coupling guard, foundation bolts and pressure gauge with valve etc. Suitable cement concrete foundation duly plastered, with anti vibration pads etc. complete as per manufacturer"s design & standards and as per detailed specifications. Spec. : As directed by Engineer-in-charge
29Supplying, Installation, Testing and Commissioning of Electric Driven Pressurization Pump (Jockey Pump) suitable for auto operation and consisting of following: complete in all respects as required. A)Horizontal type, centrifugal end suction type,multi stage pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal, gland packing and flow of 180 Ipm at 60 mtr. head confirming to IS:1520. B) Suitable HP (Minimum Suitable HP) squirrel cage induction motor TEFC type 2900 RPM suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP-55 class of protection for enclosure, horizontal foot mounted type with Class - "F" insulation, confirming to IS:325.C)Common base frame fabricated out of M.S channel of suitable size, flexible coupling, coupling guard, foundation bolts and pressure gauge with valve etc. Suitable cement concrete foundation duly plastered, with anti vibration pads etc. complete as per manufacturer"s design & standards and as per detailed specifications.
30Supplying, Installation, Testing and Commissioning of Electric Driven Pressurization Pump (Terrace Pump) suitable for auto operation and consisting of following: complete in all respects as required.A) Horizontal type, centrifugal end suction type,multi stage pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal, gland packing and flow of 900 Ipm at 35 mtr. head confirming to IS:1520.B) Suitable HP (Minimum Suitable HP) squirrel cage induction motor TEFC type 2900 RPM suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP-55 class of protection for enclosure, horizontal foot mounted type with Class - "F" insulation, confirming to IS:325. C) Common base frame fabricated out of M.S channel of suitable size, flexible coupling, coupling guard, foundation bolts and pressure gauge with valve etc. Suitable cement concrete foundation duly plastered, with anti vibration pads etc. complete as per manufacturer"s design & standards and as per detailed specifications.
31Fabricating, Supplying, Installation, Testing and CommissioningAir Vessel of continuous welded construction with flanged discharge header on the top of each riserfabricated out of 10mm thick dished ends and 8 mm thick MS sheet, Air Release Valve complete with suitabledrain arrangement with 25 mm dia gun metal wheel valve complete with all accessories etc. as required of the following sizes:1.2 Meter high and 250 mm dia.(For Sprinkler Riser Top)
321.2 Meter high and 450 mm dia.(For Pump House)
33Supply, Installation, testing and commissioning of pressure switches for Hydrant / Diesel Engine Driven Pump / Jockey Pumps/ Terrace pump, diaphragm type, adjustable range from 0-9 bar and a regulation range of 0.1 1.5 bar direct mounted SNAP acting type made from die cast aluminium with epoxy powder coated finish and SS316 diaphragm and other wetted parts, including necessary wiring upto control panel & other materials as required as per specifications.
34SUB HEAD - II - (HYDRANTS SYSTEM)Supplying and fixing Single Headed Internal Landing Valve oblique pattern with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked, conforming to IS:5290 :1983 type"A" with 80 mm dia flanged inlet, with ABS cap and chain complete with all accessories etc. as required. (MAKE: SAFEGUARD/NEWAGE)
35Supplying and fixing Single Headed External Hydrant Valve (Stand Post) oblique pattern with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked, conforming to IS:5290 :1983 type"A" with 80 mm dia flanged inlet, with ABS cap and chain complete with all accessories etc. as required. (MAKE: SAFEGUARD/NEWAGE)
36Supply, Installation, Testing and Commissioning of 100% synthetic flax canvas Non-percolating FIRE hose (Type A),I.S.I marked63mm dia x 15m long with stainless steelmale & female couplings (ISI marked) bound & riveted to hose pipes with copper rivets and copper wire as required.(For Internal Hydrant/s)
37Supply, Installation, Testing and Commissioning of 100% synthetic RRL FIRE hose (Type A),I.S.I marked63mm dia x 15m long with stainless steelmale & female couplings (ISI marked) bound & riveted to hose pipes with copper rivets and copper wire as required.(For External Hydrant/s)
38Supplying and fixing Stainless Steel branch pipe with 20mm dia nozzle conforming to IS:903. suitable for installation connections to hose coupling etc. as required.
39Supplying and Fixing First Aid Hose Reel, wall mounting swinging type complete with drum & bracket of MS construction, spray painted in Post office Red, confirming to IS 884/1995 with upto date amendments, complete with the following as required.A) 36 Meter long 20 mm dia water hose Thermoplastic (Textile reinforced) Type - 2 as per IS : 12585 B)25 mm dia ball valve & nozzle. C) Drum and brackets for fixing the equipments on wall. D) Connection from riser with stop valve (gun metal) & M.S. Pipe
40SITC weather proof M.S cabinet size 750 mm x 200 mm x 600mmSupplying, installation, testing and commissioning ofweather proof M.S Box size 750 mm x 600 mm x 200mm deep- A) Fire Hoses 63mm, 15 M long with accessories - 2 Nos. B) Short branch- 1 No. C) The cabinet shall be painted with onecoat ofprimer and 2 coats of synthetic enamel paint ofapproved shade.
41Providing and fixing 4 way gunmetal suction collecting head as per IS: 904-1983, hose coupling (draw out connection) with female outlet as per 903 complete with 150 mm dia. G.I. Suction pipe (with puddle flange) with a foot valve with strainer complete as per drawings.
42Providing and Fixing 15 mm dia gunmetal / brass quartzoid type Sprinkler Head with quartz bulb and set to operate at specified temperature. Upright, 68° C, Chrome plated (Above Flase Ceiling)
43Pendent type, 68° C, Chrome plated (Below False Ceiling) with sprinkler flexible pipe 1.2M/1.5M with support as required.
44for External Gallery & Corridors
45Extended Side wall type, 68° C, Chrome plated
46SITC of sprinkler installation valveSupplying, Installation, Testing and Commissioning of Sprinklerinstallation valve with water gong, pressure gauge, drain valve etc as required 150 mm dia size etc. complete as required.
47Supplyingand fixing vane type water flow switch suitable for installation on 50 mm to 150 mmdia line for a servicepressureupto 20 kg/sq. cm. of Potter / System sensor /Angus
48SUB HEAD - III - (PIPING, VALVES AND ACCESSORIES) SITC of M.S. pipe on surfaceSupplying, laying, fixing, testing and commissioning of following sizes (NB) of ISI marked heavy class M.S. pipes including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, clamps, hangers, flanges, gaskets, nuts, bolts and washers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick orRCC walls/ slabs and making good the same etc. complete in all respect as required. (ALL WELDED) Note:- The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.150 mm dia
4980 mm dia
5065 mm dia
5150 mm dia
5240 mm dia
5332 mm dia
5425 mm dia
55Supplying, Installation, Testing and Commissioning of Butterfly valves ofPN 16 rating of following sizes with nitrile Bronze / G.M. seat duly ISI marked and stainless steel stem with lever/gear operation and cast iron body in powder coated finish for fire fighting application complete in all respects confirming to IS: 13095 as required.150 mm dia
5665 mm dia
57Providing, Installation, Testing and Commissioning of double flangedcast iron Non-Return Valve, PN 1.6 of following sizes confirming to IS : 5312 complete with rubber gasket, Gl bolts, nuts, washers etc. as required.150 mm dia
58100mm dia
59Supply, Installation, Testing and Commissioning of 100 mm dia Bourden type, Stainless Steel dial type Pressure Gauge including brass isolation valve and siphon pipe having calibration of 0 - 16 Kg / cm2
60Supplying and erecting 150 mm dia end line strainer for positive suction complete as per specification no. FF-VL/ELS.
61SUB HEAD - IV - (FIRE EXTINGUISHERS) SAFEX/LIFEGUARD Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.(MAKE: Lifeguard/Safex)
62Supply and installing ISI marked (IS:15683) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kgs.flat base including valve, discharge hose of not less than 10mm dia., 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket.(MAKE: Lifeguard/Safex) 4.5kg capacity cylinder
63Fire Fighting Main PanelSupplying, assembling, erecting, connecting, testing and commissioning of dust, damp and vermin proof free floor standing factory built sheet steel enclosed non-draw out modular type compartmentalized Panel fabricated out of 2.0 mm thick CRCA sheet hinged doors of 1.6mm thick CRCA sheet, duly painted complete with earth bus, aluminium bus bar, numbering & sign writing, interconnection & including the cost of connection through bus bar / copper conductor flexible connection with necessary interlocking with existing panel as shown in drawing as per specification and mounted with the followings. Incoming1 No. - 400A 4P MCCB of fault breaking capacity 35 kA (Ics = Icu upto 433V), fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS-13947-2 1993 as amended up-to-date complete with following accessories for each MCCB. Independent electrical/manual spring closing mechanism - 1 No. Microprocessor releasesbased relay(EMI & EMC certified) for over current, earth fault & short circuit protections with trip indications for each - 1 set.Dual core calibrated digital Multifunctional meter of class 1.0 to record demand (KVA), energy (KWH & KVAH), power factor, current (in each phase and the neutral), voltage (between phases and between each phase and neutral) and 3 Nos. dual core CT of 400 /5 A Class 1.0 accuracy and 15 VA burden. Following indicating lamps and push buttons for each MCCB with back up 2A SP MCB . a) 3 No. Phase indicating Lamps.Indicating Lamps for the following; b) Red for MCCB ON. c) Green for MCCB OFF. d) White for Trip ckt. healthy e) Orange for Auto Trip. f)Push buttons for the followings, g) Green for MCCB ON, h) Red for MCCB OFF. i)Yellow for trip alarm cancellation. j)500 Amp. 35 kA, TPNAl. Bus Bar. Outgoings:2 set of starter each comprising of 1 No. 250 Amps. 4P MCCB 35 KA (Ics=Icu) with Suitable HP fully automatic Star/Delta starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. 2 sets of starter each comprising of 1 No. 63 Amps. 4P MCBwith 10HP fully automatic DOL starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. 1 sets of starter each comprising of 1 No. 63 Amps. 4P MCBwith 10HP fully automatic Star/Delta starterwith over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. 250 Amp. 4P MCCB -2 Nos. (1 no spare)63 Amp. 4P MCB -3 No. (1 no spare) Panel Complete as above (d) Diesel Engine Control Control for Diesel Engine comprising:-(i) Auto/Manual selector switch & 3 attempt startingdevice, timers and relays as required, push buttons, start/stop in manual mode.(ii) Indication lamp for High/Low Lub. Oil pressure, High Water Temp. and Engine on indication and suitable tripping devices, overload, earth fault protection relays etc as required.(iii)Battery charger suitable for 12 V/24 V DC with boost and tickle selector switch 0-15V/0-30V DC meter 0-20A DC Ammeter. (iv) All standard relays and accessories for automatic operationof diesel engine. (e) System ControllerDesigning, Supply, Installation, Testing and commissioning of system controller to control operation of Main Fire Pump, Pressurization Pump in sequence as per specification consisting of relays, timers, sensor, annunciation window for fault indication, complete as per specification. Fire panel as above
64(G)Fire Alarm & Detection SystemManual call Box with hinge type transparent cover.
65Wall mounted acoustically treated box with 4-watt Hooter.
66Ionisation type smoke detector.(Below false ceiling) (Apollo/ System sensor) Make :Apollo/System Sensor
67Optical type smoke detector.(above false ceiling) Make :Apollo/System Sensor
68BEAM SENSOR Make:GST/ Honeywell
69Providing, fixing, testing and commissioning of 4 Zone Manual Main Fire Alarm Panel (window type), relay for actuation of hooter sealed maintenance free batteries of 7 Ah capacity of 24 volts. Make:NSD
70Supply & fixing of FRLS armoured cableof 2 x 1.5 sq. mm dia along with the accessories as complete as required. Make:Polycab
71External Power Supply for Flow Switches & Beam Sensors. Make - Omron/ Protek
72Supply, installation, testing & commissioning of response indicator.
73(C)HVAC System56 HP,28HP (14HP + 14HP) EACH MODULAR
74DAIKIN 14 HP,MODULAR ODU Unit
75Floor Mounted DX Air Handling Unit with necessary supporting arrangement, G.S.BASE CHANNEL,Copper material tube,25 mm thick of insulated panels ,cfc free puf injected, Air Flow Capacity : 8960 cfm, total static 50mm wg22.4 TR
76Ceiling mounted Cassette AC"s4.0 TR
77Accessories Remote controller Expansion Valve as per tonnage, filter drier 1 no. & ball valve 2 nos suitable for refrigerant line size AHU KIT(AHUKZ-03B)
78Refnet(INDOOR REFNET) BJF1344-CM
79Refnet(OUTDOOR REFNET) 02N1E
80WIRED REMOTES
81PART : Low side Works Ducting Site fabricated GI ducts with necessary accessories & supports 24G
8222 G
8320 G
84Acoustic Insulation (In case of GI duct application only) 25 mm thick 40kg/m3 Fibre glass board with tissue paper and and 26 G Al perforated sheet
85Thermal Insultion25 mm thick32 kg/m3a
86Air Distribution Productsi) Supply Air Grills with VCD
87Return Air Grills with out VCD
88Supply AirDiffuser with VCD (595x595)
89Duct Damper
90Return Air Fusible Link Fire Damper
91Supply Air Fusible Link Fire Damper
92Actuators
93PVC drain pipes -32NB with 9mm thick Nitrile tube section
94Electrical Panel
95CANVAS
96Refrigerant Pipe with Insulation31.8 mm.
9728.6 mm.
9822.2 mm.
9919.1 mm.
10015.9 mm.
10112.7 mm.
1029.5 mm.
103Control Cable for AHU,Actuator,thermostat
104Electrical Cable
10556 HP,28HP (14HP + 14HP) EACH MODULARinstallation,testing and commissioning of First time Gas Charging for all the above units as per there CU Piping length and the Indoor unit capacity (WithR410- A Gas)
10614 HP MODULARinstallation,testing and commissioning of First time Gas Charging for all the above units as per there CU Piping length and the Indoor unit capacity (WithR410- A Gas)
107MS Fabrication supporting for Duct Hanging, AHU & OUTDOOR Stand
108(D)General lighting Supply and installation of MAIN PANEL of following specifications as per direction of EIC Incoming 2 No. - 250A, 4P MCCB (Icu = 35/36 KA, Ics = 100%, Icu) Microprocessor Releasewith Electrical interlocking arrangement and extended rotary operated mechanism. 1 Set (3 Nos) - 250/5A, 5 VA, Cl-1 Current Transformer. 1 Set - Cl-1 CT operated digital multifunction meter showing current, voltage and frequency. 1 Set - 3 Nos R-Y-B Phase Indication Lamp with HRC Fuse Protection. Bus Bar 1 Set - 3 Nos 50 mm x 10 mm and 1 No. 50 x 5 mm for neutral, tinned Cu busbars covered with colour coded MKV graded PVC sleeves, mounted on Porcelain/DMC/SMC Insulators. (500V, 400A rating). Outgoing 3 Nos - 100A, 500/415V, 4P MCB, Icu = 10 KA, (C-Curve). 7 Nos - 63A, 500/415V, 4P MCB, Icu = 10 KA, (C-Curve). 5 Nos - 40A, 500/415V, 4P MCB, Icu = 10 KA, (C-Curve). Earth Bus Bar 25 mm x 6 mm GI flat earth bus bar running along the base of the frame covering entire length of the panel with GI bolt and nuts and number of drilled holes as required for earth connection. 1 - Danger Board. Complete Board as stated above.
109SUPPLY & FIXING OF MCB DB : Supplying and fixing Prewired TP&N MCB DB Supplying and fixing 4 way (4 + 12), Double door prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar,neutral link, earth bar, din bar, detachable gland plate,interconnections, powder painted including earthing etc. as per direction of EIC(But without MCB/ RCCB/ Isolator). Make - Legrand/Schneider/Hager/ABB/Havells 4 way (4 + 12), Double door
110Supplying and fixing of MCB "Supplying and fixing 5 amps to 32 amps rating, SP,240/415 volts, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as per direction of EIC.Make - Legrand/Schneider/ABB/C&S/Siemens"Single pole
111Supply and fixing of Power Plug PointSupplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required as per direction of EIC.
112Power Plug Point Wiring Distribution wiring with 2 x 36/0.3 (2.5 sq mm) single core stranded copper conductor PVC insulated and unsheathed copper wire (approved make) in 19 mm dia 3 mm thick polythene/PVC pipe with 1 x 22/0.3 (1.5 sq mm) PVC insulated and unsheathed copper wire as ECC, complete with all accessories embedded in wall (for 15/16A plug point) as per direction of EIC.
113Supplying and flush fixing of modular type heavy duty plug & socket unit comprising of a double pole MCB, a 25A socket and plug top (with indicator) and solid state type starter units of electronic type with high/low voltage protections, O/L protection etc and suitable for 1.0/1.5/2.0 TR AC units modular type and completely wired including cutting necessary chases and mending good damages, painting, earthing complete as required (for AC unit) as per direction of EIC.
114FOUR POLE RCCB Supplying and fixing following rating, four pole, (three phase and neutral) 415 volts, residual current circuit breaker (RCCB), ISI marked, having a sensitivity current upto indicated milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. Note: ISI marked RCCB shall be used as per direction of EIC. Make - Legrand/Schneider/ABB/C&S/Siemens63 amps, 300 mA
11540 A TO 63 A "G" SERIES MCB SUITABLE FOR MOTORL AND OTHER INDUCTIVE LOADSSupplying and fixing 40 amps. To 63 amps. Rating, 240/ 415 volts, 50Hz, 10KA "G" series, miniature circuit breaker (suitable for motor and other inductive loads and conforming to IS 8828: 1996, IEC 60898: 2002) of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Note: ISI marked MCBs of Havells / Loadster / Indo KoppTriple Pole & neutral/4pole MCB
116Single pole Blanking plateSupplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required as per direction of EIC.
117Earthing and AccessoriesEarthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover platehaving locking arrangement and watering pipe etc. with charcoal/coke and salt as required as per direction of EIC.
118Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required as per direction of EIC.
119Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required as per direction of EIC.
120Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) as per direction of EIC.
121Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required as per direction of EIC.
122Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required as per direction of EIC.
123CABLE AND ACCESSORIES : Supply of Cable: Supply of 1.1 KV grade XLPE aluminium cable of following rating. (Non Schedule Item) as per direction of EIC. 4C x 16 sq mm armoured cable.
1243.5C x 185 sq mm armoured cable.
125Laying of Cable :Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on cable tray as required as per direction of EIC.Upto 35 sq. mm (clamped with 1mm thick saddle)
126Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required as per direction of EIC. Above 95 sq. mm and upto 185 sq. mm
127Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV gradeas required as per direction of EIC.4 X 16 sq. mm (28mm)
1283½ X 185 sq. mm (57mm)
129SUPPLY AND FIXING OF PVC CONDUITSupplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the ame in case of recessed conduit as required as per direction of EIC. 20 mm
13025 mm
13132 mm
132Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required as per direction of EIC.150 mm X 75 mm X 60 mm deep
133150 mm X 150 mm X 60 mm deep
134200 mm X 150 mm X 60 mm deep
135Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required as per direction of EIC. 5/6 amps switch
1362 way 5/6 amps switch
13715/16 amp switch
1383 pin 5/6 amp socket outlet
1396 pin 15/16 amp socket outlet
140Telephone socket outlet
141TV antenna socket outlet
142Bell push
143Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required as per direction of EIC.2 Module (75mmX75mm)
1446 Module
1458 Module
146ITC of Light/fan fittings :Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/Lamps etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of EIC.
147Erection of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required as per direction of EIC.
148Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch,connection etc. as required as per direction of EIC.
149Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required as per direction of EIC.
150Wiring for light point/ fan point/ exhaust fan point/ call bell point : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required as per direction of EIC.Group A
151Group B
152Group C
153Wiring for light/ power plugWiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(For AC) as per direction of EIC.
154CIRCUIT/ SUBMAIN WIRING : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required as per direction of EIC.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For 6/16A power socket wiring)
1554 X 4 sq. mm + 2 X 4 sq. mm earth wire
1564 X 6 sq. mm + 2 X 6 sq. mm earth wire
157Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required as per direction of EIC.1 Pair
1582 Pair
159Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required as per direction of EIC.
160Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required as per direction of EIC.
161SUPPLY OF LIGHT & FAN FIXTURES:LED STRIP: Supply, installation, testing & commissioning of LED Strip Light (28 W for 5 Meter ) with driver of Philips M/Havells/Legero
162Supply of 14 W LED Down light fittings with6.5K [Syska Cat No. SSK-DL-038- 14 W or equivalent]. It must be compatable with the DMX/Dimmer controller and should be as per direction of EIC. Make -Philips/Bajaj/Havells/CG/Legero
163Supply of 7W LED SPOT LIGHTfittings withall fittings as per direction of EIC Make -Philips/Bajaj/Havells/CG/legero
164Supply of 30 W LED Down light fittings with6.5K [Syska Cat No. SSK-DDL-30W 6.5K or equivalent]. It must be compatable with the DMX/Dimmer controller and should be as per direction of EIC. Make -Philips/Bajaj/Havells/CG/legero
165Supply, installation , testing and commissioning of line ligt of Philips Model No. SP310 X LED 22 S - 6500 PSU ODWH or approved equivalent
166Supply, installation , testing and commissioning of Exit light make : Prolite/plantion
167SFI OF GI CABLE TRAY (INCL. COST OF TRAY) Supply , fabricating and installing following sizes of perforated GI cable trays including horizontal and vertical bends reducers tees cross members and other accessories as required and duly suspended from the ceiling and / or fix to steel / RCC columns, or any other structure members with MS suspenders , angles , channels etc, complete as per the direction of Engineer - in charge Supply & Installation of Perforated cable tray of size 150 mm x 25mm x 2 mm
168(E)Auditorium ChairSupplying & Fixing of Auditorium chairs with auto tipup, chair of 21" / 22" ctc in row with common PU with soft pad arm restand chair fully upholstered in our standard foam backed polyester stretch fabric as directed by Engineer-In-Charge etc complete.Spec. : As directed by Engineer-in-charge
169(F)Stage Lighting system Supply of following equipment: 100W Zoomable High Quality LED Parcan Light complete with COB Lamp source 3200K CCT Colour temperature, CRI & TLCI Values above 90, DmX 512 dimming with 2 channel conmtrol, Beam Angle of 11 to 35 Degree, Black powder coated housing, suitable for Stage lighting to illuminate the key areas. Spec. : As directed by Engineer-in-charge
170400W LED Blinder Light 30 Degree complete with 3200K/5600K CCT 4x100W Chip On Board LED Lamp source, DmX 512 dimming with 4 /8 Channel modes, Black finish housing, IP20 protection having Strobe option and smooth dimming, illuminate Stage with uniform light intensity levels.
17154 x 3W LED Par Light 3 in 1 Beam Angle 25° complete with RGBW 3W Lamp source x 54 Pcs, DmX 512 dimming with 8 Channel , Powder coatedBlack finish housing,IP20 protection having Sound Control & Master Slave Auto Run Mode. Illuminate theIndoor stage with unlimited colour effects.
17254x3W LED 3200K Par Light Beam Angle 25° complete with 3200K 3W Lamp source x 54 Pcs, Having CRI TLCI Values above 95,Flicker Free for high FPS, Smooth fade in and Fade out, High precision steady color, No heat, DmX 512 dimming with 2 Channel, 0 ~ 100%, Powder coatedBlack finish housing, IP20 protection.
173LED PROFILE SPOT LIGHT 200W "SITC of LED PROFILE SPOT LIGHT 200W LED Profile Spot Light, Power Supply: AC100V-240V, 50-60 Hz, Power Consumption: Max. 260W, LED: 200W 2 in 1 Cool White & Warm white Color, LED Life time: over 50,000 hours, high quality optical system, Light Angel: 19°/26°/36°/50°, Control Mode: DMX, Auto run and Master/Slave, DMX Channels: 2/5CH, Housing: Plastic, Color: Black, IP Rating: IP20, Net weight: 6 kgs, gross weight: 8 kgs, dimensions: 660x285x295mm.
174200 W LED FRESNEL LIGHT Feat "SITC of 200 W LED FRESNEL LIGHT Features: 200W cool white LED, Life: More than 30000 hrs, Field Angle: Spot Light (1/10 peak), 29-degrees; Soft Light (1/10 peak), 97-degrees, Manual zoom, Color Temperature: 5000K, Color Rendering Index: Ra=84, Dimmer: 0-100% linearly adjustable, Channel: 1 channel for dimmer, Housing: High-intensity die-casting aluminum, IP20
175Light fixture mouting clamp customized for suspending on fixed bars on stage made up of Aluminium or MS material complete with black powder coating matt black finish.
176Light Fixture dual safety chain made up of GI wire rope bundled and twisted together having load bearing capacity above 200 Kgs, sleve on the rope.
17712 Mtr On Stage Fixed Lighting Bar Straight as per the design made out of 40NB 48 OD Mild steel pipe dual barrel, dual construction connected with MS Flat duly powder coated with matt black texture finish. Make: Leksa, ETC, New Age
17812 Mtr FOH Fixed Lighting Bar Straight as per the design made out of 40NB 48 OD Mild steel pipe dual barrel, dual construction connected with MS Flat duly powder coated with matt black texture finish. Make: Leksa, ETC, New Age
179Power Distribution Electrical panel having a incomer of 63A floor mount / rack mount / wall mount with nuetral separation made using incomer of L&T or Schneider make, Voltmeter, Ammeter display for reading visualization, individual MCB control for 26 outgoing circuits, separate incomer control for Motor control panel supply, RYB Phase indicators internally wired using IS certified wires and cables, provided with ivery connectors for the internal terminations and external outgoing connecting points custom built as per specification and project requirement.
180High quality power junction box 4 way made up of MS Sheet metal fabricated housing black powder coated, fibre glands of suitable size fitted with Powercon or IEC connector Box 10A.
181High quality Dimming In junction box 1 way made up of MS Sheet metal fabricated housing black powder coated, fibre glands of suitable size fitted with 5 Pin DmX XLR Female socket.
182High quality Dimming Out junction box 1 way made up of MS Sheet metal fabricated housing black powder coated, fibre glands of suitable size fitted with 5 Pin DmX XLR Male socket.
183Internal Earthing System with copper bare conductors all along the cable trays, metal parts and Installation Hardwares
184Black Powder coated cable trays made out of MS Sheet fabricated fora size of 150mm with perforation for heat dessipation provided with lid.
185Black Powder coated cable trays made out of MS Sheet fabricated fora size of 75mm with perforation for heat dessipation provided with lid.
186DmX Male Female Connectors 5 Pin having rubber sheeth protection for Cross connecting DmX wiring connections
187DmX Male Termination Connector 5 Pin soldered with required capacity of resistor for signal deframing
188Opto isolated RDM enabled DmX splitter unit complete with Power In and safety fuse, 8 Output channels 5 Pin XLR in and out supporting DMX operation as per DmX 512 protocol.
189DmX Controller 24 Faders to control atleast 96 channels with master control fader, Scene saving option, 4 Set Patch editing functions, 96 Set of Scene saving options, LCD display, Smooth movement faders, Easy access key pads, DmX 512 protocol, 4 Direct access page switching buttons, Optional chase & multifunction keys.
190FRLS Copper unarmoured Flexible cable having 3 Core each of 1.5 Sq mm size
1915 Core DmX Cable with Sheathed housing on the cable, well designed insulation, low noise suitable to transmet DmX signal
192FRLS Copper unarmoured Flexible cable having 4 Core 4 Sq mm size
193Cable Connecting Circuit Boxes for the termination of cables from Electrical panel to the grid level point made out of MS Sheet metal fabricated housing duly powder coated with matt black texture finish paint, fitted with required channels and ivery connectors, necessary glands etc.
194FRLS Copper unarmoured Flexible cable having 7 Core each of 1.5 Sq mm size
195Providing and fixing wooden control room table of app size 2400x800x750mm high finished in laminate.
196(E)Auditorium STEP LIGHT Providing and fixing 75mm wide and 1000 mm long aluminium extruded step light with dual type LED. The top surface shall have antiskid rubber strip. The down nose to have 6 nos 1 watt LED to illuminate the step riser. The step lights to be fixed over existing levelled surface with steel screws. Color of LED s. Warm White
197Drivers for step lights and led light 20 Nos step Lights
198Providing and fixing 12 volt chair lights with row marking and two layers of LED;s . The lights to be provided with 12 volt power supply .
199Providing and fixing self-contained single sided exit sign green in color for wall / ceiling / pendant cantilever mounting with 3W LED maintainance free battery with backup 2-3 hours duration, connection testing etc. as reqd..
200(F)Stage Furnishing systemSUPPLY, INSTALLATION, TESTING AND COMMISSIONING of MAIN CURTAIN made out of Fire retardant velvetcurtain cloth with horizontal sliding arrangement complete with fixing rails, brackets, sliding arrangement & motorised operation complete with runners, master runners, pullies, 3mm steel wire rope (Usha Martin), 1 HP or Higher motor (Crompton/Kirloskar / Bajaj) 2nos. air breaker contactors (L&T/SIEMENS), 2nos. micro switches for auto stop, 3 nos push buttons for forward, reverse and stop positions. The curtain should be draped to half area when in closed position. Minimum overlap at centre should be 900mm and should be stitched in double gathering with Masking Frill 500mm Drop from Proscenium. Including front frill in same cloth complete with accessories. Track System: Custom Made.
201SUPPLY, INSTALLATION, TESTING AND COMMISSIONING of MIDDLE and REAR CURTAIN made out of FR treated glazed cotton curtain cloth with horizontal sliding arrangement complete with fixing rails, brackets, sliding arrangement & motorised operation complete with runners, master runners, pullies, 3mm steel wire rope (Usha Martin), 1 HP or Higher motor (Crompton/Kirloskar / Bajaj) 2nos. air breaker contactors (L&T/SIEMENS), 2nos. micro switches for auto stop, 3 nos push buttons for forward, reverse and stop positions. The curtain should be draped to half area when in closed position. Minimum overlap at centre should be 900mm and should be stitched in double gathering with Masking Frill 500mm Drop from Proscenium. Including front frill in same cloth complete with accessories. Track System: Custom Made.
202Providing & fixing of the Border frills out of FR treated glazed cotton fabric black colour ( weight not less than 350 gms/sqm Make Nexgen/ RSWM/Banswar Syntax)) fabric in 1:2gathers & acessories like cotton dori eyelets of brass complete with 25mm dia medium grade GI pipe painted black suitably hung from the ceiling complete of size 1mtr x 14mtr approx . The work shall be executed as per drawings ,specifications & instructions of engineer in charge.
203Providing & fixing transparent acrylic podium made of well polished 15mm thick acryic sheet, top sheet of 26inchX20inch, bottom sheet 26inchX20inch, middle self 12inchX5inchX8mm thick, panel size 12inchX12inch and having University Logo imprinted
204Providing and fixing fabric wings on stage made of FR treated glazed cotton fabric fabric stitched with pleats, fixed to ceiling frame with pivoted arrangement. The bottom of wings to be provided with weight to prevent sway.
205P/f of the cyclorama for the stage by fixing 35x35x5mm MS angle on the wall with MS angle hold fasts secured to the walls & 40mm dia 14G MS pipe welded to it as per the drgs. Further 40mm dia pipe welded to it at 600 centres verticaly at an angle of 45 deg. & finally welding 40 mm dia pipe horzontally to it. The pipe to be supported away at 200mm centers by MS pipe.(MS framework payable separately) Further welding to it 12mm dia MS hooks welded both (top ,bottom & sides). The cyclorama frame to be supported by MS angle hold fasts of 35x35x5mm on the wall at 1200mm centers. Finally fixing PVC perforated screen, cyclorama cloth as per approved sample & fixing by cotton dori 10mm thick complete.The work shall be executed as per drawings ,specifications & instructions of engineer in charge.