Tender For Repair / Maint / Replacement Of Unsv Lt Panel / Apfc Panel And Re-Routing Of Ug Cable, Shifting Of Electrical Panel Board And Other Connected Works At 39 Wing Af Stn Udhampur, udhampur-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair / Maint / Replacement Of Unsv Lt Panel / Apfc Panel And Re-Routing Of Ug Cable, Shifting Of Electrical Panel Board And Other Connected Works At 39 Wing Af Stn Udhampur. Submission Date for this Tender is 12-06-2023. Electrical Panel Tenders in udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

37681591
Corrigendum : Tender For Repair / Maint / Replacement Of Unsv Lt Panel / Apfc Panel And Re-Routing Of Ug Cable, Shifting Of Electrical Panel Board And Other Connected Works At 39 Wing Af Stn Udhampur
Open Tender
Indian
Jammu And Kashmir
udhampur
12-06-2023

Tender Details

Repair / Maint / Replacement Of Unsv Lt Panel / Apfc Panel And Re-Routing Of Ug Cable, Shifting Of Electrical Panel Board And Other Connected Works At 39 Wing Af Stn Udhampur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-May-2023 FINANCE BID Financial Bid 05-06-2023
2 05-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 12-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 48000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : REPAIR / MAINTENANCE / REPLACEMENT OF UNSV LT PANEL / APFC PANEL AND RE-ROUTING OF UG, SHIFTING OF ELECTRICAL PANEL BOARD AND OTHER CONNECTED WORK AT 39 WING AF STN UDHAMPUR
Sl. No. Item Description
1M & L for repair/replacement to APFC panel of any make upto capacity 60 KVAr located at various location of39 Wing AF Station Udhampur including taking down to control wiring/relay/contactor/CT/PT/capacitor bank, cleaning with air blower & replacement to non functional part etc and reassembling, testing, commissioning, Re-programming of relay & increasing or decreasing of steps all including of fixing additional contactor, fuse unit, MCCB & Control / power wiring etc shall be included in quoted rates. Note :- (i)Spare items shall be measured and paid separately. (ii) The schematic plan of each APFC panel shall be got aproved from GE before start of repair work. (iii) The rates quoted by the contactor shall include cost of any other spare parts not mentioned herein but essentially required for functioning of the system.(iv)Unit rates quoted by tenderers shall deem to include for Nuts&bolts, washers, lugs, thimble, wires etc alongwithwelding job if required and petty items required for efficient and smooth functioning of the equipment without any extra cost to the Govt.
2Supply only cylindrical heavy duty capicitor 440/415 (V) (AC) 3 phase, 50 Hz for APFCpanel complete all as specified and directed by engineer in charge KVAR rating Make : havells/ HPL/ L&T/ HAVELLS/C&S/ABB/EPCOS
31 KVAR
42 KVAR
55 KVAR
610 KVAR
720 KVAR
8Supply only in replacement POWER contactor for capacitor switching 3 pole AC operated for APFC panel 9A make- L&T C&S/ABB/HAVELLS/Schneider
9Supply only in replacement 1 kVar CAPACITOR DUTY contactor for capacitor switching 3 pole AC operated for APFC panel make: L&TC&S/ABB/havells/Schneider
10Supply only in replacement2 kVar CAPACITOR DUTY contactor for capacitor switching 3 pole AC operated for APFC panel make: L&TC&S/ABB/havells/Schneider
11Supply only in replacement 5 kVar CAPACITOR DUTY contactor for capacitor switching 3 pole AC operated for APFC panel make: L&TC&S/ABB/havells/Schneider
12Supply only in replacement 10 kVar CAPACITOR DUTY contactor for capacitor switching 3 pole AC operated for APFC panelmake- L&TC&S/ABB/Havells/Schneider
13Supply only in replacement 20 kVar CAPACITOR DUTY contactor for capacitor switching 3 pole AC operated for APFC panelmake- L&TC&S/ABB/Havells/Schneider
14Supply only in replacement Alternating current miniature circuit breakers c curve type of capacity 10 amps, tripple pole complete all as specified and directed by Engr-in-Charge.
15Supply only in replacement Alternating current miniature circuit breakers c curve type of capacity 25 amps, tripple pole complete all as specified and directed by Engr-in-Charge. Make : Schneider /ABB/ Legrand/ C&S
16Supply only in replacement pilot lights direct integral LED of 230 volts ,colour redcomplete all as specified and directed by Engr-in-Charge.
17Supply only in replacement pilot lights direct integral LED of 230 volts ,colour green complete all as specified and directed by Engr-in-Charge.
18Supply only in replacement HRC fuse of capacity 32 Amps ,500 V, AC Type FA as per IS :13703(part-II),IEC :60269-2 complete all as specified and directed by Engr-in-Charge.
19Supply only in replacement single core 4 sqmm PVC insulated FRLSHstranded copper cable
20Supply only in replacementsingle core 6 sqmm PVC insulated FRLSHstranded copper cable
21Disconnecting and dismantling the electrical connection and shifting of Lt APFC Panel by disconnecting incoming and outgoing cable including all accessories including nut, bolt, washer and thimble etc complete and refixing of the Lt APFC panel on staging by embedding the panel legs minimum 30 cm in ground/staging and adding a layer of PCC 1:2:4, 100 mm thick and re-connecting base of panel shall be atleast 45 Cm from ground level. All metal work like provn of glands, civil work etc shall be deemed to be included in quoted rates all as specified and directed by Engr-in-Charge.
22M&L for in replacement of Varlogic APFC relays- classic range RT6,6 step ,440 volts,5 Amps complete all as specified and directed by Engr-in-Charge. Make : Schneider -electric,cat part No. 51207 or its equivalent asLegrand/ C&S
23M&L for in replacement of Varlogic APFC relays- classic range RT8, 6 step ,440 volts,5 Amps complete all as specified and directed by Engr-in-Charge. Make : Schneider -electric,cat part No. 51209 or its equivalent as Legrand/ C&S
24M&L for in replacement ofcapacitor duty contactor (AC coil),nominal reactive power 440 volts, 3 phase , 50 Hz of capacity 12.5 KVAR with auxilliary contacts (1 NO+2NC) complete all as specified and directed by Engr-in-Charge Make : Schneider -electric,cat part No. LC1DFK* or its equivalent Legrand/ ABB/ C&S.
25M&L for in replacement ofcapacitor duty contactor (AC coil),nominal reactive power 440 volts, 3 phase , 50 Hz of capacity 25 KVAR with auxilliary contacts (1 NO+1NC) complete all as specified and directed by Engr-in-Charge. Make : Schneider -electric,cat part No. LC1DMK11*C or its equivalent Legrand/ ABB/ C&S
26M&L for in replacement ofcapacitor duty contactor (AC coil),nominal reactive power 440 volts, 3 phase , 50 Hz of capacity 40 KVAR with auxilliary contacts (1 NO+2NC) including taking down old complete all as specified and directed by Engr-in-Charge Make : Schneider -electric,cat part No. LC1DTK*C or its equivalentLegrand/ ABB/ C&S .
27M&L for in replacement ofcapacitor duty contactor (AC coil),with damping resistors and block make poles ,nominal reactive power 440 volts, 3 phase , 50 Hz of capacity 60 KVAR with auxilliary contacts (1 NO+2NC) complete all as specified and directed by Engr-in-Charge. Make : Schneider -electric,cat part No. LC1DWK*C or its equivalentLegrand/ ABB/ C&S
28M&L for in replacement of three phase voltmeter CI0.5as per IEC 61010-1,50 HzAC,LED indicators complete complete all as specified and directed by Engr-in- Make: : Schneider -electric,cat part No. METSEDDM3210 or equivalent approved model in Legrand/ ABB/ C&S Charge.
29M&L for in replacement of three phase Ammeter CI0.5as per IEC 61010-1,50 HzAC,LED indicators complete complete all as specified and directed by Engr-in-Charge. Make: : Schneider -electric,cat part No. METSEDDM3110 or equivalent approved model in Legrand/ ABB/ C&S
30M&L for in replacement of MPP heavy duty can type, power capacitors 3 phase 12.5 kVAr,440 volts ,50 Hz complete all as specified and directed by Engr-in-Charge. Make : Schneider -electric, /ABB/ Legrand/ C&S
31M&L for in replacement of MPP heavy duty can type , power capacitors 3 phase 5 kVAr,440 volts ,50 Hz complete all as specified and directed by Engineer-in Charge Make : Schneider -electric,cat part no.MEHVCHDY050A44or equivalent approved model in Legrand/ ABB/ C&S complete all as specified and directed.
32M&L for in replacement of Alternating current miniature circuit breakers c curve type of capacity 10 Amps, tripple pole complete all as specified and directed by Engr-in-Charge.
33M&L for in replacement of Alternating current miniature circuit breakers c curve type of capacity 25 Amps, tripple pole complete all as specified and directed by Engr-in-Charge. Make : Schneider /ABB/ Legrand/ C&S
34M&L for in replacement of Alternating current miniature circuit breakers c curve type of capacity 32 Amps, tripple pole complete all as specified and directed by Engr-in-Charge. Make : Schneider /ABB/ Legrand/ C&S
35M&L for in replacement of Alternating current miniature circuit breakers c curve type of capacity 50 Amps, tripple pole complete all as specified and directed by Engr-in-Charge. Make : Schneider /ABB/ Legrand/ C&S
36M&L for in replacement of Alternating current miniature circuit breakers c curve type of capacity 63 Amps, tripple pole complete all as specified and directed by Engr-in-Charge.Make : Schneider /ABB/ Legrand/ C&S
37M&L for in replacement of pilot lights direct integral LED of 230 volts ,colour redcomplete all as specified and directed by Engr-in-Charge.
38M&L for in replacement of pilot lights direct integral LED of 230 volts ,colour green complete all as specified and directed by Engr-in-Charge.
39M&L for in replacement of non illuminated pushbuttonturn to release of dia of head40 mm ,type of contact NC colour red complete all as specified and directed by Engr-in-Charge.
40M&L for standard extended rotary handle for 100/160/250 Amp complete all as specified and directed by Engr-in-Charge.
41M&L for Compact typeMoulded case circuit breakerswith micrologic 2.3 of capacity 400 Amps with protection ,Ics=100% Icu as per IEC60947-2 complete all as per specified and directed by Engineerincluding taking down old Make : Schneider- electric Model No : NSX400N or equivalent approved model in Legrand/ ABB/ C&S
42M&L for Compact typeMoulded case circuit breakerswith micrologic 2.3 of capacity 250 Amps with protection ,Ics=100% Icu as per IEC60947-2 including taking down old complete all as specified and directed by Engr-in-Charge. Make : Schneider- electric Model No : NSX250N or equivalent approved model in Legrand/ ABB/ C&S
43M&L for Compact typeMoulded case circuit breakerswith TMD of capacity 160 amps with protection ,Ics=100% Icu as per IEC60947-2including taking down old complete all as specified and directed by Engr-in-Charge. Make : Schneider- electric Model No : NSX160N or equivalent approved model in Legrand/ ABB/ C&S
44M&L for EasypacttypeMoulded case circuit breakerswith TMD of capacity 100 amps with protectionas per IEC60947-2 including taking down oldcomplete all as specified and directed Make : Schneider- electric Model No : CVS100B or equivalent approved model in Legrand/ ABB/ C&S .
45M&L in repair for single corestranded copper conductor cable s of size 150 sqmmFR type1.1KV complete all as specified and directed by Engr-in-Charge. Make;- Polycab/ Finolex/ Havells/ Grandlay
46M&L in repair for Lugs of size 150 sqmm of made coppercomplete all as specified and directed by Engr-in-Charge.
47S&F in repair of HRC fuse of capacity 32 Amps ,500 V, 3 W, AC Type FA as per IS :13703(part-II),IEC :60269-2 complete all as specified and directed by Engr-in-Charge.
48M&L in repairindoor tape insulated ring type CT of ratio 100/5, 200/5 or 300/5 A ,or as per existing make or modelomplete all as specified and directed by Engr-in-Charge.
49Material and labour for LT distribution panel installation at sub staion by using cotton waste, cloth , air blower etc all as specified and directed by Engr-in-Charge.
50S&F in repair for Moulded case circuit breakers 4 pole ,415 volts,adjustable type, ICS100% of ICU, 0.8 ln to 1ln,320/350 Amps with breaking capacity 35/36 KA,50 Hz complete all as specified and directed .
51S&F in repairfor Moulded case circuit breakers 4 pole ,415 volts,adjustable type, ICS100% of ICU, 0.8 ln to 1ln,250 Amps with breaking capacity 35/36 KA,50 Hz complete all as specified and directed by Engr-in-Charge.
52S&F in repairfor Moulded case circuit breakers 4 pole ,415 volts,adjustable type, ICS100% of ICU, 0.8 ln to 1ln,160 Amps with breaking capacity 25 KA,50 Hz complete all as specified and directed by Engr-in-Charge.
53Supply and LayingCable XLPE insulated screened PVC bedded galvanized steel strips or wire armoured,cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade and connecting and testing in trenches, under floors/ roads or on wallsincluding taking down old complete all as specified and directed offollowing sizes :- (Note 1.: Earth work, excavation shall be measured & paid separately under respective item of Schedule and wherever cable laying on walls and uses of thimbles etc rates shall deemed to be included in the quoted rates).
5495 Sqmm, 3.5 Core
55120 Sqmm, 3.5 Core
5610 Sqmm,4 core cable
5725 Sqmm, 3½ core cable
5835 Sqmm,3½ core cable
59Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and foundation of poles, stays and getting out in any type of soil complete all as specified and as directed by Engr-in-Charge.
60Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
61Removing surplus excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete, all as specified and as directed by Engineer-in-Charge.
62M & L for Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. by Engineer-in-Charge. Note: Punned thickness of sand shall be measured.
63Common burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other complete all as specified and directed for cable protection.
64S&F in repair of GI tube light grade of bore 50 mm with all fittings and fixed complete to walls and ceiling or laid in floor for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable up to building heightcompleteall as specified and directed by Engr in charge
65S&F in repair of GI tube light grade of bore 80 mm with all fittings and fixed complete to walls and ceiling or laid in floor for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable up to building heightcompleteall as specified and directed by Engr in charge
66M&L complete for drilling hole through machine underhard standing /road in different location as per site requirement (between 03 mtr to 40mtr maximum) for laying ofpipe for protection of cable etc by means of bookle and without disturbing the top surfaceand making good the disturbed surface if any complete all as specified.
67Material and Labour for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate in coping etc for pole/panel including necessary form work for fair finished exposed concrete surfaces complete all as specified and directed.
68M&L for type C2 1:3:6 (40 mm graded aggregate) cement concrete in foundation and mass concrete etc complete all as specified and directed by Engineer-in-Charge.
69Supply and fix heat shrinkable End termination kits and accessories of following capacities and type:- Note for item No 45 (a) to 45 (c):- Rate for the execavation, returing filling and removing of the earth work and provide labour and Electrician shall deemed to be included in the quoted price, not extra be paid for this items.
70Outdoor/indoor 120 to 150 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
71Outdoor/indoor 95 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
72Outdoor/indoor 35 to 50 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable
73Supply and fix heat shrinkable straight through joint kit and accessories of following capacities and type:-
74Straight through joint kit aluminium conductor cable of size 120 to 150 Sqmm and 3.5/4 core
75Straight through joint kit aluminium conductor cable of size 35 to 50 Sqmm and 3.5/4 core
76Straight through joint kit aluminium conductor cable of size 95 Sqmm and 3.5/4 core
77Disconnecting and dismantling the electrical connection and shifting of Lt Panel boards by disconnecting incoming and outgoing cable including all accessories including nut, bolt, washer and thimble etc complete and refixing of the Lt panel on staging by embedding the panel legs minimum 30 cm in ground/staging and adding a layer of PCC 1:2:4, 100 mm thick and re-connecting base of panel shall be atleast 45 Cm from ground level. All metal work like provn of glands, civil work etc shall be deemed to be included in quoted rates all as specified and directed by Engr-in-Charge.
78Disconnecting and dismantling the electrical connection and shifting of electrical poles by disconnecting incoming and outgoing cable including all accessories complete and refixing the pole by excavation, returning & filiing and removal of any type of soil including PCC 1:3:6 type C-2 with using 40 mm graded crushed stone aggregate as in foundation and PCC1:2:4 type B-1 using 20 mm graded crushed stone aggregate in coping etc forall as specified and directed by Engr-in-Charge
79Supply and fixing of suitable size of nut bolts / washers complete all as specified and as directed including taking down old.
80Repair/maint and overhauling of L.T.Panel 3 phase AC415V, 50 Hz A of any make including Taking out old /UNSV MCCBs & MCBs /incoming and outgoing laminated copper busbar , DMC/epoxy insulators of any size ,Volt meter, Amp meter, phase indicator LED lamp,Change over switch of any capacity ,burnt out copper winding ,current coil ,potential coiland keeping aside for safe custody for re-use, opening the L.T. Panel, removing gasket, dismantling and taking out old parts carefully, disconnecting all conections, & re-assembling all serviceable parts to original position including cleaning , removing sludge, dirt, dust, cleaning of parts including removal of old paint with 02 coat synthetic enamel machine spray paint after 01 coat iron red oxide machine spray paint along with replacement of unsv nuts, bolts, thimbles, gasket etc as per site requirement including denting, welding and replacement of unsv hinges if requirement complete testing all as specified and directed by Engineer-in-Charge. Note : (a) All spare parts and control wiring will be measured and paidseperately under respective item of Sch "A". are as under. (b)Denting, welding, replacement of unsv hinges, locking arrangement, handle, unsv gasket, cable gland, nut, bolt, washer, minor repair of PCC foundation if required and removing of old paint alongwith reassembling, testing, commissioning etcshall be deemed included into the quoted rate.
81Supply only in replacementfor MCCB 4 Pole, 415 V, fixed type,thermal magnatic loadICS100% of ICU, 0.8 ln to 1ln, 63 Amps with breaking capacity 16 KA complete all as specified and directed. Make :- Standard/Havells/Schneider/ABB or equivalent as approved by GE.
82Supply only in replacementfor MCCB 4 Pole, 415 V, fixed type,thermal magnatic loadICS100% of ICU, 0.8 ln to 1ln, 100 Amps with breaking capacity 36 KA complete all as specified and directed. Standard/Havells/Legrand or equivalent as approved by GE.
83Supply only in replacementVolt meter (0-500V) digital type with selector switch-01 No. Make : Secure or equivalent approved make.
84Supply only in replacementAmmeter(0-50 amps) digital type with CTs and selector switch -01 No Make : Secure or equivalent approved
85Supply only in replacement Set of indicating lamp LED type-01 Set.
86Civil work PCC 1:2:4 for grouting of panel complete Size- (0.25x0.25x0.25 cum x 04) including excavation, earth work.
87Supply only in replacement Copper insulated bus bar with DMC/porcelain insulator etc made out of laminatedas per existing size 40 mm x 5mm complete all as specified and directedby Engr-I n-Charge.
88Supply only in replacement Copper insulated bus bar with DMC/porcelain insulator etc made out of laminatedas per existing size 50 mm x 6mm complete all as specified and directedby Engr-in-Charge.
89Supply only in replacement Current transformer of suitable size as per existing
90Supply only in replacement for cutting the existing cable from loop and existing panel and making sleeves over the existing cable suitable for LT U/G cable of size 25 to 50 Sqmm all as specified and directed by Engineer-in-Charge.
91Supply only in replacement Copper wiring 1.5 Sqmm as per existing size
92Supply only in replacementpad lock in the panel not less than 6 liver Make-Godrej/Harission
93M & L for CRCA MS Sheet of any size/ thickness alongwith fixing arrangement through nut, bolts or welding etc suitable for panel base plate or panel canopy all as specified and directed by Engineer-in-Charge. Note :- (i) Rate include for making the hole in the gland according to the size of cable and re-connecting the cable in the existing panel etc. (ii)Size of sheet shall be as decided and directed by Engineer-in-Charge.
94S & F street light bracket made out of 40/50 mm dia GI heavygrade tubing not less than 1.5 Mtr long bend to shape including pole clamps made out of 50 x 6 FI and nut bolts and washers complete all as specified and directed by Engr-in-Charge.
95Disconnecting and taking down old unserviceable ATS of any description and capacity and Supply and fixing of Automatic Transfer Switch as per Conforms to IEC:60947-1 and IEC:60947-6-1four pole ,AC -31A,50 Hz,415 Voltsof capacity 315 amps automatic /manual with inbuilt time delay with enclosure complete including fixing the ACB in the panel by cutting/drlling, nut, bolts and washers etc shall deemed to be included in the quoted rate all as directed and specified by the Engr-in-Charge.Make cat part No. IHYFCDE315 of :Havells or its equivalentas Standard
96Supply and fix Powder coated Pin Type Panel lock in round shape (Male & Female socket) diameter appx 22 mm for female socket complete all as specified and as directed by Engr-in-charge
97Supply only non -metallic PVC clamps requiredfor cables laying above the wall/drainage/PCC area of size 20 sqmm etc.complete all as specified & as directed.
98Supply only non -metallic PVC clamps required for cables laying above the wall/drainage/pcc area of size 40 sqmm etc.complete all as specified & as directed.
99Laying over ground cables/Re-routing only LT UG cable of size 10 sqmm x 2,10 sqmm x 4 core to 185 sqmm x 3.5 core cable to be relayed/ rerouted shall be exisiting over ground/ under ground label" along with connection with LT panel/Pole or Other electrical equipment with proper thimble/Aluminium lugs etc making all electrical connections as directed by Engr-in-Charge. Note :- (i)Execavation shall be got done alongwith other items of cable required for laying of cable and shall be paid in respective items for laying existing overground cables. (ii) Quoted rates shall be inclusive of cutting of cable, provision of thimbles, lugs, stainless steel cable gland for connecting cable IN / OUT from Panels and Feeder Piller Boxes as per Site requirement. (iii) The crimping shall be done only by Hand Operated / Hydraulically Operated Crimping Tool after applying conducting jelly and no other method will be allowed. (iv) Extra use of cable shall be measured & paid separately in case of non availability of EM store. (v)Execavation, Returning & filling, removing, sand and break workshall be measured and paid separately. (vi) Cable may also be provided from stores as sch "B" as decided by Engr-in-Charge.
100Supply and fixing LED Tiranga Rop light 18 Mtr , IP 65, Input Power 10W/meter,Input Voltage 220-240V AC, Input Frequency 50 Hzs, Input Current 0.045 Amp/mtr, Power Factor 0.95, Width of strip (+/- 0.1mm) 8 mm, length/reel - 18 Mtrs, Nos of led per mtr 120 LED, LED Beam angle 120 degree, Rope light per Colors length 6 mtr orange, 6 mtr white, 6 mtr Green, Fixing method silicone clip, ingress protection - IP 65, Ingress protection method silicone tube, silicone tube dimention 11.5 x 5.5 mm + 0.5 mm, working temp range -20 degree celcius to + 45 degree celcius, working humidity range 10-90 RH and all as directed by engr in charge. Make : HPL Cat part No - HPLTRGL10WPMTR or equivalent in approved make.
101Supply & installation and testing & Commissining CPRI approved outdoor cubical type IP 54,LT feeder piller box suiable for 415V, 3 phase 50 Hz , AC supply system, dust,weather& vermin proof, made of 3.15 mm thick MS sheet for outer shell and 2 mm thick for inner shell having TPN copper busbars of rating 600 Amp Cap of length not less than 60 cm and suitable size of strip for 3 phase and neutral with colour code heat shrinkable sleeve and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, inter connection of incoming and outging cable etc and Bottom base channel of MS section not less then 50 mm x 50 mm x 5 mm thick grouted in PCC block of size 30 cm x30 x 90 cm (30 cm depth below ground level and 60 cm above ground level) in cement 1:3:6, type C-2 (using 40 mm grade crushed stone aggregate and connection of cables with suitable size of thimble, nuts, bolts & washers including cable glands at entry and outlet points including execavation and earth work, returing filling and removal of surplus soil, double door both side opening single door system lockable/openable by key from both sides having flush pattern fancy locks with louvers as per site requirement with the following :- (a)CT"s ration 600/05, CL 1.0 Tape wound - 01 set (Set of three) (b)Digital Voltmeter & Ammeter - 02 Nos (b)Phase indicator lamp RYB LED type -1 Set (Set of three) Incoming: (a) MCCB 400 Amp 415V, 50 Hz,FP, 36 ka, Ics= 100% Icu, fixed type complete all as specified and directed by Engr-in-Charge. Note :-Panel shall be installed at least 60 cm above ground
102Supply & installation and testing & Commissining CPRI approved outdoor cubical type IP 54,LT feeder piller box suiable for 415 V, 3 phase 50 Hz , AC supply system, dust,weather& vermin proof, made of 3.15 mm thick CRCA sheet, TPN copper busbars of rating 200 Amp Cap.Bottom base channel of MS section not less then 45mmx45mmx5mm thick, entire panel shall have a common aluminium earth bar of size 25mm x5mm at the rear with 2 no earth stud,double door both side opening single door system lockable/openable by key from both sides having flush pattern fancy locks with louvers. cable entry with glands, foundation/grouting on & including PCC as per site requirement with the following :- (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulator 200 Amp,4 pole, not less then 45 CM long mounted on insulators for incoming supply - 1 Set (Set of 4 strips) (b) Phase indicator lamp RYB LED type-1 Set (Set of three). (c) Digital Voltmeter & Ammeter - 02 Nos (d) CT Ration 100/05 CL 1.0 Tape Wound - 01 Set (Set of three) Incoming: (a) MCCB 160 Amp, 415V, 50 Hz,FP,,25 ka, Ics= 100% Icu fixed type, complete all as specified and directed by Engr-in-Charge. Note :- 1.Panel shall be installed at least 60 cm above ground 2.All civil/electrical work & material is deemed to be included in the quoted rates
103M & L for SS Guy Rope wire 4 mm Hard for thor stay assembly (7x7 construction) complete all specified and as directed by Engr-in-Charge.
104M & L for SS U Clamp 5 mm suitable for thor stay assemblycomplete all specified and as directed by Engr-in-Charge.
105M & L for SS D Clamp 6 mmsuitable for thor stay assembly complete all specified and as directed by Engr-in-Charge.
106M & L for SS Adjustable Clamp 8 mmsuitable for thor stay assembly complete all specified and as directed by Engr-in-Charge.
107S & F in repairs, installation, commissioning and testing Polycarbonate ASTA CPRI approved OEM made Outdoor Power Supply Panel. The Panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURESwhich should be UV resistance in accordance with IEC 61439-1, clause 10.2.4:, anti-acid, anti corrosive & Shock Proof. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262.DEGREE OF INGRESS PROTECTION IP 65IN ACCORDANCE WITH IEC 60529 and panel should passed glow wire test 960oC in accordance with 60695-2-11 [flame retardant and self-extinguishing]. The gasket should be internally embedded made of polyurethane and Enclousers makeHensel/Clipsal.The manufacturer of panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1.Submit The ASTA CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak, short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits and submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer.The Panel Floor Mounting type with stand and Copper Bus 125A TPN with Color Coding . Make- Hensel/Rittal/Emitter/Schneider/ABB. Incomer :- MCCB 100A FP25 KA Thermal/Magnetic Released with Spreader Link - 1 No LED indicator RYB - 1 Set Outgoings Socket 63A 5P 3P+N+E CEE Type - 1 No(Make - Walther/Hensel) Socket 32A 3P 1P+N+E CEE Type - 1 No(Make - Walther/Hensel)
108S & F in repairs, installation, commissioning and testing Polycarbonate ASTA CPRI approved OEM made Outdoor Power Supply Panel Mini. Size 700x975x525mm. The Panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURESwhich should be UV resistance in accordance with IEC 61439-1, clause 10.2.4:, anti-acid, anti corrosive & Shock Proof. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262.DEGREE OF INGRESS PROTECTION IP 65IN ACCORDANCE WITH IEC 60529 and panel should passed glow wire test 960oC in accordance with 60695-2-11 [flame retardant and self-extinguishing]. The gasket should be internally embedded made of polyurethane and Enclousers makeHensel/Clipsal.The manufacturer of panel SHALL submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1.Submit The ASTA CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak, short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits and submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer.The Panel Floor Mounting type with stand and suitable Copper Bus with Color Coding . Make- Hensel/Rittal/Emitter/Schneider/ABB. Incommer :- RCCB 100A FP100mA - 1 No. Outgoings :- MCB 63A TP with Socket 63A 5P 3P+N+E CEE Type - 1 No(Make - Walther/Hensel) MCB 32A TP with Socket 32A 3P 1P+N+E CEE Type - 1 No(Make - Walther/Hensel) MCB 32A TP with Socket 16A 3P 1P+N+E CEE Type - 2 No(Make - Walther/Hensel) MCB 16A DP with Socket 16A 3P 1P+N+E CEE Type - 6 No(Make - Walther/Hensel)