Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-06-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-06-2023 |
| 2 | 23-05-2023 | AMENDMENT | BOQ | 06-06-2023 |
| Sl. No. | Item Description |
| 1 | Receiving / recording complaints under Haig Line Power House of HT UG/OH electric distribution network, to comprehensive maintenance by attendng daily complaints including Sunday and other holidays for round the clockand making the same serviceable in all respects alongwith replacement of any major part but including small length of cable (not more than 20 mtr), adhesive tape and other connected minor accessories shall also include to visual inspection of OH lines, Earth Resistance of transformer, switch gear, GOD switch etc.Quoted rate also include excavation offaulty cable are making seviceable with accessories like joints, Fuze wire for GOD switch complete all as directed to the entire satisfacation of Engineer-in-charge.Note ‘A’ :-(i)Any complaint left unattended by the electrician will be communicated to the JE in-charge /AGE E/M with reason. No charge will be paid for the per complainttill the complaint is resolved.(ii)New material /stores provided for completing the job shall be measured and paid for separately under relevant items of BOQ.(iii)Contractor shall provide all type of T&P of HT network, bamboo ladder (30 Feet) with safety gloves to each electrician for attending the external electric complaints.(iv)Contractor shall provide the complaint register 200 pages – 10 No, complaint book with 100 slips- 20 No. Booklets serially numbered in triplicate. (v)Contractor will provide 03 No. Experienced Electrician having minimum 5 years experience ( 01x three shifts per day) and 03 No. Helper having minimum 2 years experience( 01 x three shifts per day) including Sundays and Holidays to attend HT Complaints.(vi) Contractor will provide well experienced and well conversant of one person for lodging the complaint in complaint cell of each power houseduring workinghours from 0900hrs to 1700hrs on all working days including Sunday & all Holidays.(vii)The Contractor will provide insurance cover of minimum Rs 5 lakh per head under IE Rules 2003 and Minimum wages Act. (viii) The Electrician and helper will be interview by JE E/M /Engr-in-charge for verification of experience, character and sound mind and body. (ix)Cost of materials for laying of cables,strecthing of OH conductor, burnt out joints, fuse wires, insulator andjumper will be measured and paid separately under relevant items as Material & Labour. |
| 2 | Receiving / recording complaints under Haig Line Power House of LT UG /OH electric distribution network, street lightsto comprehensive maintenance by attendng daily complaints including Sunday and other holidays for round the clockand making the same serviceable in all respects alongwith replacement of any major part but including small length of cable (not more than 20 mtr), adhesive tape and other connected minor accessories shall also include to visual inspection of OH lines, Earth Resistance of transformer, switch gear, GOD switch etc.Quoted rate also include excavation offaulty cable are making seviceable with accessories of all nature likeNo light, faulty insulator, broken conductor & cable fault , burnt out MCCB`s, MCBs, isolators, switch fuses,service cables etc upto DB in buildings/OTM in Sector `B`areacomplete all as directed to the entire satisfacation of Engineer-in-charge.Note ‘A’ :-(i)Any complaint left unattended by the electrician will be communicated to the JE in-charge /AGE E/M with reason. No charge will be paid for the complaint per day till the complaint is resolved.(ii)New material /stores provided for completing the job shall be measured and paid for separately under relevant items of BOQ.(iii)Contractor shall provide all type of T&P of LT network, bamboo ladder (23 Feet) with safety gloves to each electrician for attending the external electric complaints.(iv)Contractor shall provide the complaint register 200 pages – 10 No, complaint book with 100 slips- 20 No. Booklets serially numbered in triplicate. (v)Contractor will provide 03 No. Experienced Electrician having minimum 5 years experience ( 01x three shifts per day) and 03 No. Helper having minimum 2 years experience( 01 x three shifts per day) including Sundays and Holidays to attend HT / LT Complaints.(vi)The Contractor will provide insurance cover of minimum Rs 5 lakh per head under IE Rules 2003 and Minimum wages Act. (vii) The Electrician and helper will be interview by JE E/M /Engr-in-charge for verification of experience, character and sound mind and body. (viii)Cost of materials for laying of cables,stretching of OH conductor, burnt out joints, fuse wires, insulator andjumper will be measured and paid separately under relevant items as Material & Labour. |
| 3 | Note for items No 01 to 02 :-(i)The contractor shall have to provide additional ManPower/resources as per the direction of Engr-in-Charge for speedy disposal of complaints as andwhen required. If any manpower is absent penal charge @Rs 1000/- per person will be levied from the contractor. Penal recovery @ Rs 500/- per complaint per hour will be levied from the contractor in case of late attending of complaint after reasonable time or 2 hours whichever is more as decided by Engr-in-Chage / GE(ii)The scope of work shall cover all complaints received from above concern power houses will be lodged/docketed/attended/completed.The completion report will be rendered on complaint register as well as on docket. Nature of fault may occurs given below :-(a)Blown out fuses,(b)Faulty Insulator,(c)Loose GOD male & female contact, (d)Fault cable joint,(e)O/H conductor broken,(f)Broken jumpers (g)Tightening of stay,(h)Stretching of broken loose fault conductor and binding on insulators up to 3 span(j)Contractor will provide all the tools such as HT/LT meggar, Insulation Tester, Wrench, Rope, Bamboo ladder, search light and other tools and will maintain them in working condition all the time till completion of contract.(k)Tightening of service connection as preventive maintenance(l)Proper Uniform shall be provided by the contractor for pers employed on duty as desired by Engr-in-Charge.(m)Tracing fault manually in LT/HT electric lines and underground cable network,(n)AC Complaints like connection / disconnection.(o)Fault HT/LT switchgears (p)Switching ON/OFF street lights at appropriate time as directed by JE/Engr-in-Charge.Penel recovery for Rs 100/- per day will be recovered if street light not put ON/OFF at appropriate time. (q) The area covered under the above power house consists of HT/LT overhead lines. HT/LT underground cables, distribution transformers, HT/LT switch gears, street lights etc, including HT 11 KV incoming and numbers of outgoing HT feeders for the complete area.(r) Any other electric complaint which is considered essential by the department.(s)Confirmation on completion of any nature of major complaints will be intimated to JE concerned to the area or Engr-in-Charge immediately.(t)The contractor will observe all labour laws as prevalent during the currency of work enacted by Central/State Deptt as well as Labour Commissioner Act.He shall also ensure, payment of minimum wages to the persons employed as per labour laws in vogue.(u)Insurance, Education Qualification and experience cert for the personnel employed on duty shall be submitted to Engr-in-Charge before taking over the installation. (v) The contractor will provide the rain coats, gum boot and hand gloves HT/LT.(w)Contractor will have no rights to object the work carrying out by other contractor at substation or HT/LT distribution system of the power house area under comprehensive maintenance. However necessary handing taking over the assets will be carried out between the agencies.(x)Contractor will be provide vehicle (3/4 wheel) for attending the complaint under above power house area.. |
| 4 | Labour only for carry out visual inspection of transformer once in monthincluding minor maintenance like dusting ,tightening of loose connection HT/LV Side and replacement of aluminium terminal and checking of transformer oil level ,top up if required ,checking of silca gel, heating/ replacement of silca gel all as specified and as directed.T&P required for the job is deemed to be included in contract. The record of the same will be submitted in the performa as directed by Engr-in-Charge. |
| 5 | Trimming of Tree branches falling on OH lines of HT/LT & minimum clearance of 3 Mtrfrom branches ,Proper shutdown will be taken and maintained in the register complete all as specified and as directed. |
| 6 | Maintenance of sub Station including cleaning In /out of surroundings areas, zeroing of grass in two pole & four pole str ,loose filling of sands/pebbles as required,operations of GODs ,Measuring of earth resistance of transformer,GODs ,LA & Switchgears ,Records of Earth resistance will be maintained Quarterly and signed by JE E/M /Engr-in-Charge all as specified and directed by Engr -in-Charge. |
| 7 | Detecting of fault in cable HT/LT with fault locator equipment which is capable to supply as per cable of HT/LT (11 KV/430 Volts) serviceable to cable with Straight throughjoint of size 95-185 Sqmm.Notes(a) The HT fault which is detected through cable fault locator will only be paid under this item including transportation charges demed to be included in the quoted rate.(b)Charge of cable fault locator and DG set including transportation charge deemed to be included in the quoted rate.(c) Earth fault locator will be provided by the contractor for even single HT fault and no delay on this account will be acceptable otherwise penalty will lived Rs 500/ per hour.(d)Straight through joint , 95 to 185, sqm, Labour charges, excavation and making joint deemed to be including in quoted rate. |
| 8 | Material & Labour indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.5/4.0 x 25-50 Sqmm |
| 9 | Material & Labour indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 70-120 Sqmm |
| 10 | Material & Labourindoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 150-185 Sqmm |
| 11 | Material & Labour indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.50240-300 Sqmm |
| 12 | Material & Labour only straight through joint heat shrinkable 1100 Volts for XPLE cable of size 3.5/4 x 25-50 Sqmm |
| 13 | Material & Labour straight through joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 70-120 Sqmm |
| 14 | Material & Labour straight through joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 150-185 Sqmm |
| 15 | Material & Labour in replacement of old UNSV shackle type porcelain vitreous white or brown insulator including GI straps washers, insulator bolts and nuts for working pressure 1100 volts, 75 mm hight, 90 mm dia, section of strip 30mmx3mm & dia of bolt 12 mm complete all as specified and as directed. |
| 16 | Material & Labour in replacement of aluminium conductor steel reinforced (ACSR). |
| 17 | Material & Labour 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core |
| 18 | Material & Labour in replacement of MCCB TPN 400 Amps, 415 Volts, 36 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type with thermal magnetic release complete all as specified and directed. |
| 19 | Material & Labour in replacement MCCB TPN 250 Amps, 415 Volts, 25 KA, 4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type complete all as specified and directed. |
| 20 | Material & Labour in replacement of MCCB TPN 200 Amps, 415 Volts, 25 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type complete all as specified and directed. |
| 21 | Supplyonly in replacementMCCB TPN 100/125 Amps, 415 Volts, 16/18 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type complete all as specified and directed. |
| 22 | Material & Labour aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 50 sqmm |
| 23 | Material & Labour aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 70-185sqmm |
| 24 | Material & Labour aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 240-400 sqmm |
| 25 | Suply only chemical (Round up) for remove unwanted vegitation/grass at various locations . |
| 26 | Material & Labour straight through joint heat shrinkable 11 KV earthed system suitable for XLPE cable of size 3 x 70-120 Sqmm incl taking down old unsv HT joint complete all as directed by Engr-in-charge . |
| 27 | All as per item ser No 25 here in before but for cable 150-240 sqmm 3 core |
| 28 | Material & Labour cable end termination jointing kit HT 11 KV grade earthed system (heat shrinkable) outdoor type complete with jointing material suitable for HT XLPEcable 70-120 sqmm 3 core 11 KV grade earthed system incl taking down old unsv HT joint complete all as directed by Engr-in-charge . |
| 29 | All as per item ser No 27 here in before but for cable 150-240 sqmm 3 core |
| 30 | Supply and fix in repair LT line separators 1100 V grade PVCspacer to separate LT conductor from each other 3/4 line as per IS complete all as specified and directed by Engr-in-Charge. |
| 31 | All as per item ser No 29but for 5 line |
| 32 | Re-stretching existing/retrievedACSR conductor on LT /HTpoleand binding conductor on insulator properly using new binding wire/jumper wire complete all as directed by Engr-in-Charge.Note : (i) Each Run of line conductor shall be measured & paid for separately. |
| 33 | Material & Labour for in replacement of steel nuts, bolts, washers of any size required at siteas specified and directed by Engineer-in-Charge. |
| 34 | M&Ldanger notice board/plate of 1.6mm thickmild steel sheet , vitreous enameled red colour with letters, figures , and conventional skull and bone in signalwhite colour and fixed with MS clamps bolts approved size ofr HT 25cmx20 cm. |
| 35 | Supply only ofTinned copper fuse wire of size 27/33 S.W.G. for GODISI marked all as specified and as directed. |
| 36 | All as per item ser No 34here but for 23/24 S.W.G. |
| 37 | Supply only ofPVC self adhesive insulation tape ofSize .125mm x 25mm x 25 mtr long ISI marked all as specified and as directed. |
| 38 | Supplyonly for loose filling in substations, under poles, under transformers of hard core broken to gauge not exc 63 mm broken stone/boulders incl leveling and spreading llime stone powder under stones complete all as per direction of Engr-in-Charge. |
| 39 | M&L for providing plain cement concrete type C-2, 1:3:6 (using 40 mm grade aggregate) as in coping, finished even and fair, including necessary from work all as directed at site. |
| 40 | Material & Labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed inclusive of one primer coat, one under and one finishing coat of aluminium paint all as specified including taking down the old unsv cross arms and misc accessories. |
| 41 | Supply only pouring new transformer oil as per IS : 335 (1993)for transformers installed at various site for topping up to achieve the di electric strength 60 KV at 4 mm gap, complete all as specified and as directed by Engr-in-Charge.Note : Transformer oil shall be brought at site in sealed container from the original manufacturer and shall be opened in front of Engr-in-charge, Container shall be deposited by the contractor to the deptt, which will be returned after completion of conract. |
| 42 | Labour onlyin replacement of silica gel 4-6 mesh suitable for transformers breather andprotect VCBs, RMUs from moisture at 11 KV stations complete as per site requirement complete, all as specified and as directed. |
| 43 | Dismantling and taking down old unsv GOD and Supply, installing, testing and commissioning of air break gang operated triple switch( GODO) outdoor type , vertical mounting type of capacity 200 Amp with drop out fuse consisting 12 insulators ISI marked mechanically operated mounted on insulator and frame work with operating GI rods and mechanical work from ground level with locking arrangement including Godrej pad lock with two keys complete with fuse carrier andHT fuse elementhaving upto 200 Amp rating suitable for HT 11 KV 50 HZ ACsupply including necessary electric connection complete all as specified and directed by Engr-in-Charge. |
| 44 | Dismantling and taking down old unsv LA andSupply, install, test and commission lightening arrestor suitable for HT 11 KV expulsion type 65 KA 11 KV rating complete all as specified directed. |
| 45 | Material & Labour for surface cleaning of LTsteel tubular poles9 mtrs long including removing rusted particles painting withtwo coats of synthetic enamelaluminium paint over a coat of red oxide including stand cross arms, bracing, supports,clamps eye hooks, security light bracket clamps etc providing black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paints incl repairing and painting on coping with cement base white paint complete all as directed.Note : (i)The quoted rate shall includes making of numbers on self adhesive stickers on each LT pole as per direction of Engr-in-Charge.(ii)The quoted rates shall including the repairing of coping with cement / PCC (1:2:4) |
| 46 | Material & Labour for cement base paint for PCC pole 9 mtr includingblack & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paint and painting with two coats of synthetic enamel aluminium paint over a coat of red oxide including cross arms bracing supports, clamps, eye hooks, security light bracket, clamp etc inclincl repairing and painting on coping with cement base white paint complete all as directed.Note : (i)The quoted rate shall includes making of numberson self adhesive stickers on each LT pole as per direction of Engr-in-Charge.(ii)The quoted rates shall including the repairing of coping with cement / PCC (1:2:4). |
| 47 | Material and labour in replacement of broken earth pit of size 300x300x300 mm madeof PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia TMT bars @ 100 mm centre to centre both ways with handle made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers as required at site with testing result all as specified and directed. |
| 48 | Material and labour in repairs of stay by tightening of stay wire after untying the conductor spans from the poles to make correct tensions and maintain verticality of poles, including re-jointing the conductors in position with new binding wire all as specified and directed. |
| 49 | Repairing of existing unserviceable PCC coping of LT/HT pole by breaking completely and material and labour for PCC 1:2:4 type B1, (using 20mm graded crushed stone aggregate) of size 600X600X300mm including form work and applying two coats of white wash all asspecified and directed. |
| 50 | Supply and fixing in replacement of off load change over switch with sheet steel Enclosure 415 V, 4 pole, 100 Amps capacity fixed on walls for electric supply distribution between main and DG set incl necessary connection of cable from LT panels to change over switches complete all as specified and directed by Engr-in-Charge. |
| 51 | All as per item ser No 49 but for 200 Amps capacity |
| 52 | Material and labour for shifting heavy items / excavation / cleaning areas / cleaning site by providing crane/hydra/excavators/tractors/trolley ect as required at site complete, all as specified and as directed. |
| 53 | S&F in replacement of bracket made out of GI tubing single piece not welded, bended at proper angle of size 40mm dia, light grade 1.5 mtr long including painting with aluminium paint over one coat of red oxide primer to the bracketwith clamp from juction box to connecter of street light fitting all as specified and as directed. |
| 54 | S&F in replacement of MS clamp suitable for holding street light bracket on steel/PCC polemade out of 40 mm x6 mm thick flat iron with M.S nuts bolts 50 mm long 10 mm dia-3 Nos with flat washer 3mm thick -02 No for each includingpainting with aluminium paint over one coat of red oxide primer to the M.S clamps all as specified and as directed |
| 55 | S&F in replacement of extended spreaders link should be installed both side with exisitng/new MCCBs 4P/3P of any capacity with existing LT panels complete all as specified and directed by Engineer-in-Charge. |
| 56 | M&L Chemical spray (DC 2.26 contact cleaner) in container of 415 ml/300g for precision blended multipurpose product for prevents corrosion penetrates, lubricants, displaces and seals out moisture release rusted mechanisum cleanese etc complete all as specified and directed by Engr-in-Charge. |
| 57 | Supply and fixing in replacement of fabrication of Kiosk box made out of fibre material complete with TPN ,aluminium bus and suitable for one number MCB (SP) including one No MCB (SP) 6 Amps 240 volts with glands for incoming & out going cable including fixing of flat iron clamps of size 20x4mm on PCC/Steel tubular polecomplete all as specified and as directed by Engr-in-Charge. Make: Havells/Sintex. |
| 58 | Supply and fix in replacement of MCB SP 6-32 Amps, 240 volt,10 KA \"C\" curveincluding all accessories complete all as specified and directed. |
| 59 | Supply and fix in replacement of MCB DP 16-40 Amps, 240 volt,10 KA \"C\" curveincluding all accessories complete all as specified and directed. |
| 60 | Supply and fixing in replacement of single core PVC unsheathed multi stranded copper cable (FRLS) 1.5 Sqmm nominal cross sectional area 1100 volts conforming to IS 694 including electrical connection suitable size of lugs, nuts and bolts complete all as specified and directed. |
| 61 | All as per item ser No 59but for 2.5 sqmm |
| 62 | Supply and fixing in replacement of rigid non-metallic PVC conduit of dia 20 mm exclusive of boxes (Junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. Note: PVC pipe will be clamped at three position on pole and cost of clamp, nut, bolts etc are incl in quoted rates complete all as specified and directed. |
| 63 | Taking down old unserviciable display board and supply and fixing of Retro reflective sign board of size 600 x 750 sqmm made of ACP sheet of 3mm thick ACP sheet shall be fixed on MS frame with legs of MS angle section 35mm X 35mm X 4mm grouted in PCC 1:3:6 type C-1, 750mm above the ground level and 600mm below the ground level. The background of board to be provided with red colour, letters and border with white retro reflective tape. Same description shall be mentioned on both sides of ACP sheet complete all as specified and directed.NOTE:- (i) Excavation, earth work, PCC, nuts, bolts, fasners, paint on MS frame and legs shall be included in quoted rates by contractor.(ii) The size of letters and description shall be all as per sample approved by Engr-in-Charge. |
| 64 | M&L XLPE cable insulated screened, PVC bedded galvanized steel strip of wire armored , electric power cable (Heavy duty ) with aluminum conductor 11000 volts grade cross sectional area 95 sqmm 3 core suitable for 11 KV earthed system incl taking down old unsv HT cable complete all as directed by Engr-in-charge . |
| 65 | Supplying and fixing in replacement oflight gradegalvanised mild steel pipe 80mm bore with all fittings, laid under roads, drain, paths, fixed to poles/walls with suitablemild steel clamps, bolts, nuts and washersall as specified and directed. Note:- Excavation & earth work shall be measured and paidfor separately under appropriate item of this schedule. |
| 66 | All as per Item No 64 here in before but of size 50 mm dia. |
| 67 | Dismantling and taking down security light, street light, hanger light, flood light and high mast lights of any type at any height fittings such asHPSV/HPMV/MH/LED light of 48 Watt/ 60 watt / 70/72 watt/ 90 watt/ 120 watt/ 150 watt/ 200 watt and 300 watt of any make etc. AC 230 volts any wattage from pole/wall roof top/hanger roof including washing/cleaning of perplex cover inspection for location of faultand replacing of defective speare/parts required for smooth functioning, tighting of electric connection complete and assembling and reconnecting all as per site requirment all as specified and directed. Note: Defective spare/ part of relevant light fitting shall be measured and paid separately under relevant item as supply only. |
| 68 | Supply only LED electronic driver/adaptor/SPDfor40-60 watt LEDsecurity light fitting existingmakeall as specified and directed. |
| 69 | Supply only LED electronic driver/adaptor/SPDfor70/72 watt LEDsecurity light fitting existing makeall as specified and directed. |
| 70 | Supply only LED electronic driver/adaptor/SPDfor90 watt LEDsecurity light fitting existing makeall as specified and directed. |
| 71 | Supply only LED electronic driver/adaptor/SPDfor60-150 watt LEDflood light fitting existing makeall as specified and directed. |
| 72 | Supply only LED electronic driver/adaptor/SPDfor200-300 watt LEDflood light fitting existing makeall as specified and directed. |
| 73 | Supply & fixingin replacement of Integral LED Flood light Luminaries 150 Watts consisting of suitable number of LEDs andmounted on MCPCB high pressure die cast aluminium housing with sealed toughened glass cover with secondary optics lens,IP 66 protection suitable for mast light mounting, 5700K,LED efficiency >100 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -10ºC to 50ºC,built in surge protection of more than 10 kV ,Confirm the tests from auth labs :LM79 & LM 80, incl proper fixing and testing of flood lights on 9/11 mtr long steel tubular pole and provide facility of power supply shall be provide as suitable for maint work of light fittings incl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge.Note :-PVC heavy duty conduit pipe along with 3/1 run of 1.5/2.5 sqmm PVC insulated unsheathed/sheathed copper multistranded conductor from MCB box to flood lightshall be measured and paidfor separately. |
| 74 | Supply & fixingin replacement ofLED street light fitting90 watts made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover/ toughened glass having TOP Opening seperate driver compartment with IP 66 protection and impact resistance of IK07 consisting of suitable number of LEDs with sealed toughened glass cover, 5700K,LED efficiency >100 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 140 V-270 V, Power factor> 0.95,mains current 0.270A, working temperature range-10ºC to 50ºC,built in surge protection of more than 10 kV, better optics for uniform distrubution with multiple LEDs not less than 2 watt each and having optical grade polycarbonate lens with all accessories , suitable for side entry, pole mounting with bracket arm OD 40 mm, recommended mounting height with suitable inground reinforcement is 8 mtrs, Confirm the safety test as per IS 15885 part-2 from auth labs :LM79 & LM 80, incl proper fixing and testing of street lights on 9/11 mtr long steel tubular poleincl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge. Note :-PVC heavy duty conduit pipe along with 3/1 run of 1.5/2.5 sqmm PVC insulated unsheathed/sheathed copper multistranded conductor from MCB box to street light shall be measured and paidfor separately. |
| 75 | Disconnecting & taking out defective underground cable from trenches, pole, pipe, floor, wall etc and locate the fault, rectify the defect and relaying the XLPE cable underground PVC insulated and overall sheathed aluminum conductor heavy duty 100 volts including connecting and testing for any size complete as directed by Engineer-in-Charge (Excavation/earth work & sand cushioning, bricks and joint shall be measured & paid for separately). |
| 76 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose/soft soil and getting out for underground cable/erection of poles, stays etc complete all as specified and as directed by Engineer-in-Charge. |
| 77 | All as per Srl item no.75 here in beforebut exceeding 1.5 mtr deep but not exc 3.0mtr deep. |
| 78 | M & L sand cushioning for cable with river washed sand and punning to provide required cover as per SSR part I complete all as specified and as directed by Engineer-in-Charge. |
| 79 | Supplying and laying un-reinforced precast concrete cable cover, class precast concrete cable cover, class HV,Type 1 with peak, size 300mm x 180 mm x 40 mm complete all specified and directed by Engr-in-charge. |
| 80 | Supplying and laying bricks common burnt clay sub class \"B\" old size for cable protection complete all as specified and as directed by Engineer-in-Charge. |
| 81 | All as per Item Ser No 79 but except bricks.Note: Old bricks retrieved from item No 87 here in after shall be used. |
| 82 | M&L for PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone for mass filling in polepit and foundation etc including provision of necessary form work to achieve fair finished surfaces complete all as specified and as directed. |
| 83 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge. |
| 84 | Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as directed by Engineer-in-Charge. |
| 85 | Supply , erection of PCC pole 9.0 mtr long in true vertical position 102x172 mm at top 102x279 mm at bottom class-10 incl providing black and white strips with synthetic enamel point 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black strip complete all as specified and as directed by Engr-in-charge. Note: Earth work and PCC shall be measured and paid separately. (ii) Description as per direction of Engr-in-Charge will be printed on each pole without any extra cost. |
| 86 | Supply,errection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type SP-31 (9 mtrs long) inclproviding black and white strips with synthetic enamel point 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black strip complete all as specified and as directed by Engr-in-charge. Note: Earth work and PCC shall be measured and paid separately. (ii) Description as per direction of Engr-in-Charge will be printed on each pole without any extra cost. |
| 87 | Dismantling and taking down old unserviceable PCC/Steel pole any type after disconnecting all electrical connectionincl clearance of site complete all as the direction of Engr-in-Charge. |
| 88 | Disconnecting & taking out defective underground cableany size and any type from trenches, pole, pipe, floor, wall etc |
| 89 | Supply and laying, connecting and testing XLPE underground cableinsulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 6 sqmm 2 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on walletc. Note:(i) Earth work, sand, bricks , removing, returning filling Aluminium thimbles/lugs will be paid separately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates. (iii) All equipments , machinery or toolsif required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost. |
| 90 | All as per Item No 88 here in before but of size 10 Sqmm 2 Core |
| 91 | All as per Item No 88 here in before but of size 10 Sqmm 4 Core |
| 92 | All as per Item No 88 here in before but of size 16 Sqmm 4 Core |
| 93 | All as per Item No 88 here in before but of size 35 Sqmm 3.5Core |
| 94 | All as per Item No 88 here in before but of size 50 Sqmm 3.5Core |
| 95 | All as per Item No 88 here in before but of size 95 Sqmm 3.5Core |
| 96 | Material and labour for preparatory work for priming and distempering with Washing, rubbing down and stopping of distempered and painted surfaces on walls complete all as specified and as directed. |
| 97 | All as per Item No 95 but on celings |
| 98 | Material & Labour for Clearcolle on plastered and other surfaces,preparatory to distempering with primer complete all as specified and as directed. |
| 99 | All as per Item No 97but on celings |
| 100 | Material & labour for Distempering walls with distemper oil emulsion two coats complete all as specified and as directed. |
| 101 | All as per Item No 99 but on ceilings single coat . |
| 102 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 103 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and as directed. |
| 104 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification. Two or more coats complete all as per specified and as directed |
| 105 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including applied @ 2.20 kg/10 sqm) priming coat of exterior primer complete all as specified and as directed. |
| 106 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and as directed. |
| 107 | Note:-Amount of credit ofRs 70873.00 for retrieved materials is mentioned in Schedule of Credit attached in tender documents in pdf form which will be deducted offline while acceptance of tender. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy