| Sl. No. | Item Description |
| 1 | Excavationin trenches in soft/loose soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out complete all as specified and as directed. |
| 2 | Excavationin trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out complete all as specified and as directed. |
| 3 | Returning filling in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed. |
| 4 | Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. |
| 5 | M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particalsin trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shallbe measured 18 cm after punning. |
| 6 | Supply and laying un-reinforced precast.concrete cable protection cover of class LV, type-1, flat size 250mm x 150mm x 40 mm,factory madeof specified make , complete all as specified and directed. |
| 7 | M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping etc including form work for poles all as specified and directed by Engr-in-Charge. |
| 8 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete for poles all as specified and directed by Engr-in-Charge. |
| 9 | M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete including form work for poles all as specified and directed by Engr-in-Charge. |
| 10 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistrandedaluminium conductor of size 400Sqmm single core as per IS 7092 Pt -I complete all as specified and directed. |
| 11 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistrandedaluminium conductor of size 300Sqmm single core as per IS 7092 Pt -I complete all as specified and directed. |
| 12 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistrandedaluminium conductor of size 150Sqmm 3.5 core as per IS 7092 Pt -I complete all as specified and directed. |
| 13 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistrandedaluminium conductor of size 120Sqmm 3.5 core as per IS 7092 Pt -I complete all as specified and directed. |
| 14 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistrandedaluminium conductor of size 95Sqmm 3.5 core as per IS 7092 Pt -I complete all as specified and directed. |
| 15 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistrandedaluminium conductor of size 70Sqmm 3.5 core as per IS 7092 Pt -I complete all as specified and directed. |
| 16 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistrandedaluminium conductor of size 50Sqmm 3.5 core as per IS 7092 Pt -I complete all as specified and directed. |
| 17 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistrandedaluminium conductor of size 35Sqmm 3.5 core as per IS 7092 Pt -I complete all as specified and directed. |
| 18 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistrandedaluminium conductor of size 25Sqmm 4 core as per IS 7092 Pt -I complete all as specified and directed. |
| 19 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistrandedaluminium conductor of size 16Sqmm 4 core as per IS 7092 Pt -I complete all as specified and directed. |
| 20 | Supply , fixin repairs ,commissioningandtestingfactory madeLTfeeder pillar, outdoortypepedstal type ,suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated . The panel shall be dust and vermin proof, IP 65 class protection and made of3.15mm CRCA MS sheet and 50x50x5mm thick angle iron base frame work,powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside,both side openingtype, with aprons for cable entry,with double door shutter and locking arrangement and consisting of the followingall as specified.LTPanel board should be as per IS/IEC 61439-I: 2011 &IS/IEC 61439-2 : 2011, Type Test certificates for Short Circuit Test, Temperature Rise Test, Di-ElectricProperty Test and Degree of Protection IP-65 at minimum 4000 Amps with Breaking capacity not less than 65KA.The panel shall be powder coated finish with RAL 7032 SIEMENS GRAY STRUCTURE after seven tank phosphating treatment, front & back opening type, andfixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel with voltage and danger indicated in Hindi and English, with double door shutter and shall have louvers and airvent gasket for natural flow of air, Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following ( The contractor should submit all Certificates before executing the job.) Panel drawings and make of MCCB will be submitted by contractor for approved by GE before supply of panel on site. |
| 21 | (a)Aluminumbus barfour strips800 Amps ,415 volts, fixed horizontally, duly insulatedwithheat shrinkable sleeves in colour code - 01 Set. Incoming(b)Air circuit breaker04 Pole, 630 Amp 50 KAfor one second as per IS/IEC 60947-2ICS=ICU =100% fixed type with thermal magentic release ,manual operatedfitting etc complete etcOutgoing(c)MCCB,04 Pole, 250 Amps with ultimate breaking capacity 25 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I- 02 No (Ics=Icu=100%)(d) MCCB,04 Pole, 160 Amps with ultimate breaking capacity 25 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I - 02 Nos (Ics=Icu=100%)(e )Volt meter 0-500 volt, with selector switch withMCBs - 1Set.(f) Ampmeter 0-800 Amps with selector switch with MCBs- 1Set.(g) Indication lamps R,Y,B LED type with 3 Nos of 2A MCBs-1 set:h) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminumstrips for MCCB\"s.(j) Spare way for MCCB 160Amp 4 Pole-01Nos |
| 22 | All as per srl item No 20 here-in-before but comprising of following:-(a)Aluminumbus barfour strips400 Amps ,415 volts, fixed on epoxy insulatedwith panel fixed horizontally duly insulated withheat shrinkable sleeves in colour code - 01 Set. Incoming(b)MCCB,04 Pole, 200 Amps with ultimate breaking capacity Icu=35KA at 415 volts with fixed thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 01 Nos (Ics=Icu=100%)Outgoing(c)MCCB,04 Pole, 160 Amps with ultimate breaking capacity Icu=25KA at 415 volts, adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 02 Nos (Ics=Icu=100%)(d)MCCB,04 Pole, 100 Amps with ultimate breaking capacity Icu-25 KA at 415 volts adjustable type withthermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 01 Nos(Ics=Icu=100%)(e) Spare way for MCCB 100Amp 01 No(f) Analog type voltmeter 0-500 Volt with selector switch With MCBs-1 Set(g) Ampmeter 0-200 Amps with selector switch with MCBs- 1Set.(h) Indication lamps R,Y,B LED type with 3 Nos of 2A MCBs-1 set: j) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminumstrips for MCCB\"s. |
| 23 | Supply , installing, testing and commissioning factory made and tested, CPRI approvedLTfeeder pillar, outdoortypefloor mounted,suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated . The panel shall be dust and vermin proof, IP 65 class protection and made of3.15mm CRCA MS sheet and LT panel shall be as per IS/IEC 61439-I: 2011 &IS/IEC 61439-2 : 2011 and mounted on angular frame work of 50x50x5mm thick angle iron base frame work,minimum 60 cm high and fixed with PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside,both side openingtype, with aprons for cable entry,with double door shutter and locking arrangement and consisting of the followingall as specified including taking down old feeder pillar and taking out LT cables from loop for connecting in new panel and necessary excavation etc and consisting of the following:- Note:Panel drawings and make of MCCB will be submitted by contractor for approved by GE before supply of panel on site. |
| 24 | (a)Aluminumbus barfour strips600 Amps ,415 volts, fixed horizontally, duly insulatedwithheat shrinkable sleeves in colour code - 01 Set. Incoming(b)MCCB,04 Pole, 400 Amps with ultimate breaking capacity Icu-25 KA at 415 volts, adjustable type withthermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 01 No (Ics=Icu=100%)Outgoing(c)MCCB,04 Pole, 200 Amps with ultimate breaking capacity 25 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I- 02 No (Ics=Icu=100%)(d) MCCB,04 Pole, 160 Amps with ultimate breaking capacity 25 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 Nos (Ics=Icu=100%)(e )Spare way for 125 Amp, MCCB 4 way-01Nos(f) voltmeter digital type 0-500 Volt -1 Set(f) Ampmeter digital type 0-400 Amps - 1Set.(g) Indication lamps R,Y,B LED type -1 set:h) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminumstrips for MCCB\"s. |
| 25 | M & L for earthing in repairscomplete with galvanized steel earth plate electrode600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level)with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common saltupto 1.5 meter depth all around the earth plate and connected to earth leadof GI strip 32x6 mmby means of bolts, nuts, check nuts and washers of galvd iron or steel surronded by charcoal of coke and saltand protected by galvanized iron or steel pipe light grade 40 mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of2009 and also including making test point for testing of earthingmade out ofgun metal or phosphorous bronge size 75x75x25 mm complete . Note : 1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmmin lieu of CI cover.2. Charcoal dust and commonsaltupto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate inside earth pit .On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values less than 2 ohms.3. The cost of GI earth lead and GI pipe of 7.50m lenth for protection of GI wire and excavationwork fpr pit shall deemed to be included in this item. |
| 26 | M & L for earthingcomplete with galvanized steel earth plate electrode600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level)with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common saltupto 1.5 meter depth all around the earth plate and connected to galvanised earth lead4 mmdia by means of bolts, nuts, check nuts and washers of galvd iron or steel surronded by charcoal of coke and saltand protected by galvanized iron or steel pipe light grade 40 mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 5 of MES schedule Pt I of2009 and also including making test point for testing of earthingmade out ofgun metal or phosphorous bronge size 75x75x25 mm complete . Note : 1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmmin lieu of CI cover.2. Charcoal dust and commonsaltupto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate inside earth pit .On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values less than 2 ohms.3. The cost of GI earth lead and GI pipe of 7.50m lenth for protection of GI wire and excavationwork fpr pit shall deemed to be included in this item. |
| 27 | M&L for brick work with fly ash bricks, straight or curved on plan exc 6 mmean radius , built in CM (1:4) etc completeincl demolistion of existing brick work built in cement mortar complete all as specified and directed. |
| 28 | M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surface of walls / cable duct ,finished even and fair etccomplete all as specified and directed. |
| 29 | S&F in replacement composite type LT seperators /spacers of made poly porpelene single mould capable for 3 phase ,415 volts LT ACSR conductor over head distribution system of grey and white colour incl fly nuts made of engineering grade nylon studs shall be properly fixed ,spacers having minimum width 25 mm & thickness 12 mm ,voltage flactuation 12 % permissible under IES rules etc complete and direcetd. |
| 30 | S&F in replacement kiosk box for luminaires ,weather proof made out of HDPE/FRP housing fire retardant, non fusing, shock & rust proof, single piece moulded andcover with hinged door, pole mounting type comprising of four pole copper connectors of 16 Amps capacitywith 6 Amp MCB single pole , of minimum size 300x200x105mm,fixed on pole with MS, clamps 30 x 5mm with necessary nuts, washer and incl applying two coats of synthetic enamel paint over ared oxide primer on steel surface/clamps and embossing/painting of Danger sign of size not less than 10cms x 7.5cms with letter and conventional skull and bones in single red color on front face of kiosk box complete all as directed. The quoted rate also includes cost for material & repalcement of 4 sqmm multistranded twincore aluminium cable ISI marked from overhead conductor to junction box and replacement of 3 core copper cable of 1.5 Sqmm ISI marked from junction box to security light length as per required at site. Make-Syntex/Supreme/Hensal |
| 31 | S & F in replacement of GI brackets for fixing LED street light fitting fabricated out of GI tubing 40 mm dia, medium grade,1.2 mtr long , bend to 120 degree shape by cutting, welding and well finishing including MS clamp of flat iron of size 32 x 4 mm -02 Nos complete for steel poles / PCC pole as per site requirement with nut, bolt & washers for fixing of GI bracket complete all as specified and directed. |
| 32 | S&Fin replacement of new generation energy saving and enviromental friendly long life LED security/ street light fittingmade up of innovative die cast aluminium housing high power LED as lighting source with IP-66 power consumption 110 W complete input voltage of 150-240 Volts (Normal rated voltage 240Volts) complete including taking down of old unservicable street light any type/any capacity including replacement of twisted 3 core copper cable of size 1.5Sqmm dia for connecting phase, neutral and earth from junction box to LED light through copper connectors complete as specifiedand as directed. |
| 33 | S&F in replacement of new generation energy saving and environmental friendly long life LED flood light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 250 watt colour white complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including taking down of old unserviceable flood light any type/any capacity including replacement of twisted 3 core copper cable of size 2.5 Sqmm dia for connecting phase, neutral and earth from junction box to light through connectors complete as specifiedand as directed.Make :- Bajaj Cat Part No BJLF100LED I /Havells/Phillips) |
| 34 | S&F in replacement of new generation energy saving and environmental friendly long lifeLED flood light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 50 watt colour white complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including taking down of old unserviceable flood light any type/any capacity including replacement of twisted 3 core copper cable of size 2.5 Sqmm dia for connecting phase, neutral and earth from junction box to light through connectors complete as specifiedand as directed. |
| 35 | S&F for replacement & testing commissioning of outdoor type bus bar panel weather proofMS cubical panelboard made of3 mm CRCA MS sheet outdoor type of size 110 cm x 80 cm x 40 cm, 4 Nos of aluminium bus bar of 300 Amp capacity with MCCB 4 pole of Capacity 200 Amp 25 KA (Ics =Icu=100%) including one coat of redoxide and two coat of enamel paint powder coated, mounted onangular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hightand fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels,powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside and PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels & aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed. |
| 36 | S&F for replacement & testing commissioning of outdoor type bus bar panel weather proofMS cubical panelboard made of3 mm CRCA MS sheet outdoor type of size 110 cm x 80 cm x 40 cm, 4 Nos of aluminium bus bar of 300 Amp capacity with MCCB 4 pole of Capacity 160 Amp 25 KA (Ics =Icu=100%) including one coat of redoxide and two coat of enamel paint powder coated, mounted onangular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hightand fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels,powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside and PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels & aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed. |
| 37 | M&L in replacement of aluminium conductor, steel reinforced ACSR of any size/description on HT/LT poles/lines incl stringing, tightening, binding to insulators with aluminium wire making and connecting jumpers, connections etc incl connecting, commissioning and testing also taking down of the existing complete all as specified & directed. |
| 38 | M & L for loop type insulator large size with overall demensions 140 mm clearance of hole 25.5 mm complete all as specified and as directed. |
| 39 | S&F in repairs pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut of size 100 mm height, 65 mm dia for 1100 volts gradecomplete all as specified and directed. |
| 40 | S&Fin repair Shackle type 75mm height and 90mm dia insulator, porcelain,vitreous, white, brown or green including galvanised mild steel strap 31mm X 3mm, insulator bolts 12mm dia with suitable washers and nut, suitable for working pressure upto & including 1100 volts fixed on LT poles complete all as specified and directed. |
| 41 | Restretching of existing ACSR’s conductors and earth wires including cradles, of each span consists upto 5 conductor of any description, size & shape and in any position approx length 30 to 45 mtr as inoverhead lines any type, on existing poles, including opening of connections and binding wires, restringing and tightening of conductors/earth wire in position, removing sag, binding to insulators with new aluminum wire, making and connecting jumper connections etc incl commissioning and testing complete all as specified and directed.The quoted rates shall be deemed to include the following provisions also :- (i) Setting/adjusting etc in position of cradles. (ii) Adjusting & tightening of stay assembly wherever required.(iii)Trimming/cutting of all trees branches upto 3M distance from nearest conductor/earth wire as directed at site.(iv) Adjusting & tightening of cross arm,bracing,clamps, nut bolt wherever required(v) Old spacers of ACSR conductor shall be reused and fixed as directed. |
| 42 | Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP-31) 9.0 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided withtwo coats of aluminium paint overone coat of red oxide primer and incl taking down existing old unserviceable poles complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed.) Note :- Excavation incl earth work and PCC foundation will be measured and paid separately. |
| 43 | Supply, erecting and fixing in replacement of true vertical position, prestressed concrete pole 9.0 mtr long 102 mm x 172 mm at top and 152 mmx 279 mm at bottom class 10 (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size) including taking down of old unserviceble pole & shifting of cross arms ACR conductor , GI wire, insulator, street light brackets etc complete all as directed. Note :- Excavation incl earth work and PCC foundation will be measured and paid separately. The old unserviceable pole obtained from dismanting shall be remove by the contractor form cantt area/MOD. If the contractor has not removed the dismantled item a penality of Rs.500.00 per pole will be charged from the contractor as a penality. |
| 44 | Supply, erecting and fixing in replacement of true vertical position, prestressed concrete pole 9.0 mtr long 102 mm x 172 mm at top and 152 mmx 279 mm at bottom class 10 (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size) including taking down of old unserviceble pole & shifting of cross arms ACR conductor , GI wire, insulator, street light brackets etc complete all as directed. Note :- Excavation incl earth work and PCC foundation will be measured and paid separately. The old unserviceable pole obtained from dismanting shall be remove by the contractor form cantt area/MOD. If the contractor has not removed the dismantled item a penality of Rs.500.00 per pole will be charged from the contractor as a penality. |
| 45 | S & F in replacement of MCCB,04 Pole, capacity 63 Amps with ultimate breaking capacity 16 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%)in the existing panel with suitable connecting copper terminals at site complete all specified and directed. |
| 46 | S & F in replacement of MCCB,04 Pole, capacity 100 Amps with ultimate breaking capacity 25 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%)in the existing panel with suitable connecting copper terminals at site complete all specified and directed. |
| 47 | S & F in replacement of MCCB,04 Pole, capacity 160 Amps with ultimate breaking capacity 25 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%)in the existing panel with suitable connecting copper terminals at site complete all specified and directed. |
| 48 | S & F in replacement of MCCB,04 Pole, capacity 200 Amps with ultimate breaking capacity 25 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%)in the existing panel with suitable connecting copper terminals at site complete all specified and directed. |
| 49 | S & F in replacement of MCCB,04 Pole, capacity 250 Amps with ultimate breaking capacity 25 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%)in the existing panel with suitable connecting copper terminals at site complete all specified and directed. |
| 50 | S & F in replacement of MCCB,04 Pole, capacity 315 Amps with ultimate breaking capacity 35 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%)in the existing panel with suitable connecting copper terminals at site complete all specified and directed. |
| 51 | S & F in replacement of MCCB,04 Pole, capacity 400 Amps with ultimate breaking capacity 35 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%)in the existing panel with suitable connecting copper terminals at site complete all specified and directed. |
| 52 | S & F in replacement of MCCB,04 Pole, capacity 630 Amps with ultimate breaking capacity 50 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%)in the existing panel with suitable connecting copper terminals at site complete all specified and directed. |
| 53 | S&F TPN HRC typeswitch fuse unit of 415 Volt 50 Hz three phase of capacity 32 Amp including MS box with backelite fuse & fuse carrier fittings , operating insulated handle, top cover necessary locking arrangemnts etc as per IS/IEC 60947 1&3 including necessary wall mounting fitting as directedincluding taking down the existing all as specified and directed. Make : INDOASIAN / L&T/Havells |
| 54 | S&F TPN HRC typeswitch fuse unit of 415 Volt 50 Hz three phase of capacity 63 Amp including MS box with backelite fuse & fuse carrier fittings , operating insulated handle, top cover necessary locking arrangemnts etc as per IS/IEC 60947 1&3 including necessary wall mounting fitting as directedincluding taking down the existing all as specified and directed. Make : INDOASIAN / L&T/Havells |
| 55 | S&F TPN HRC typeswitch fuse unit of 415 Volt 50 Hz three phase of capacity 100 Amp including MS box with backelite fuse & fuse carrier fittings , operating insulated handle, top cover necessary locking arrangemnts etc as per IS/IEC 60947 1&3 including necessary wall mounting fitting as directedincluding taking down the existing all as specified and directed. Make : INDOASIAN / L&T/Havells |
| 56 | S&F TPN HRC typeswitch fuse unit of 415 Volt 50 Hz three phase of capacity 200 Amp including MS box with backelite fuse & fuse carrier fittings , operating insulated handle, top cover necessary locking arrangemnts etc as per IS/IEC 60947 1&3 including necessary wall mounting fitting as directedincluding taking down the existing all as specified and directed. Make : INDOASIAN / L&T/Havells |
| 57 | S & F in replacement of off load change over switch, 200 Amps, 4 pole, AC 415 Volt, 50Hz in SS enclosure side handle operated complete all as specified and directed. |
| 58 | S & F in replacement of off load change over switch, 100 Amps, 4 pole, AC 415 Volt, 50Hz in SS enclosure side handle operated complete all as specified and directed. |
| 59 | S & F in replacement of off load change over switch, 63 Amps, 4 pole, AC 415 Volt, 50Hz in SS enclosure side handle operated complete all as specified and directed. |
| 60 | Supply & fixing GI tube 80 mm bore light grade with all fittings for laid in trenches/fixed along with poles/walls & floor of buildings etc under crossing of road for protection of cables including demolition and taking down of the old existing pipe including repair of the floor/wall and matching with the existing surface if required complete as directed by Engineer-in-Charge. |
| 61 | Supply & fixing GI tube 50 mm bore light grade with all fittings for laid in trenches/fixed along with poles/walls & floor of buildings etc under crossing of road for protection of cables including demolition and taking down of the old existing pipe including repair of the floor/wall and matching with the existing surface if required complete as directed by Engineer-in-Charge. |
| 62 | Supply & fixing GI tube 40 mm bore light grade with all fittings for laid in trenches/fixed along with poles/walls & floor of buildings etc under crossing of road for protection of cables including demolition and taking down of the old existing pipe including repair of the floor/wall and matching with the existing surface if required complete as directed by Engineer-in-Charge. |
| 63 | M & L for road cutting incl necessary excavation 45 cm wide and90 cm in depth as in trenches in any type of soils/rock for laying HT/LT UG cable throughpipeafter laying /through the cable trenches will be fillingtop withM&L PCC 1:3:6 type C-1 using 20 mm grdaeds stone aggregates from top over 15 cm thick hard good of broken boulders , 63 mm gauge over 15 cm bolders 100 mm dia over filled and rammed earth to make good the disburbedsurface etc complete all as specified and directed. |
| 64 | S & F and replacement of cross arms, bracing, supports clamps and back plates fabricated from structural steel sections incl nuts & bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size and inclusive of one red oxide primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed. |
| 65 | M&L for painting of steel tubuler 11/9 mtr poles any type complete incl flat iron clamps,D clamps, Stay clamps, earth wire clamps, bracing, cross arm with two coat aluminium paint including prepration old painted surface initally & applying one coat of red oxide, applying two coat of aluminum paint over the red oxide, marking with alternate white and red strips 30 cm height 5 Nos strips with two coat of synthetic enamel paint (Ist quality of manufacturer )and also including numbering of poles with white paint are located on different locationscomplete all as specified and directed . |
| 66 | M & L for painting of steel cross arm, bracing supports of 11/9 mtr PCC poles any type incl flat iron clamps, D clamps, stay clamps, earth wire clamps, bracing, cross arm with two coat aluminium paint incl prepration old painted surface and applying cemente based paint over cemented portion of PCC poles, marking with alternator white and red strips 30 cm height 5 Nos strips with two coat of synthetic enamel paint (Ist quality of manufacturer ), numbering of polescomplete all as specified and directed. |
| 67 | S&F in replacement of HRC fuse link & bases bolted type made up of copper body of braeking capacity 80 KA ,500 Volt AC as per sampleat site ,of rating 63 Amp to 100 Amp etc complete as direcetd .Note : The rate quoted shall deemed to be inclusive of thimbles and HRC fuse and neecssary repair of SDFU and testing and commissioning |
| 68 | S&F in replacement of HRC fuse link & bases bolted type made up of copper body of braeking capacity 80 KA ,500 Volt AC as per sampleat site ,of rating 160 Amp to 200 Amp etc complete as direcetd .Note : The rate quoted shall deemed to be inclusive of thimbles and HRC fuse and neecssary repair of SDFU and testing and commissioning |
| 69 | S & F in replacement of Air circuit breaker04 Pole, 630 Amp 50KA for one second as per IS/IEC 60947-2ICS=ICU =100% fixed type with thermal magentic release ,manual operated incl dismantling and taking out old U/S ACB from panel & fabrication work to bus bars for proper fitting etc complete etc complete all specified and directed. |
| 70 | S&F in replacement Factory made sheet metal enclosure of CRCA sheet 2 mm thickness suitable for fixingofMCCB 4 with fixing arrangement including provision of MCCB 63Amp, 16KA, 4Pole( Ics=Icu=100%) with cable connection with copper glands etc complete all as specified and direcetd. |
| 71 | S&F in replacement Factory made sheet metal enclosure of CRCA sheet 2 mm thickness suitable for fixingofMCCB 4 with fixing arrangement including provision of MCCB 100Amp, 25KA, 4Pole( Ics=Icu=100%) with cable connection with copper glands etc complete all as specified and direcetd. |
| 72 | Trimming of tree branches touching to over head lines, upto 1.5 mtr distance all around of ACSR conductors of span 30meter to 50 meterof HT/LT feeders and depositing cut branches away from site as directedand clearence of HT/LT pole and sub station premises all as directed by Engg-in-charges. Note: (i)Trimming of all branches oftrees falling under one span between two poleshall be shall be considered as as one span only. (ii) Contractor have to arrange all T&P , safty equipments manpower and vehicle for trimming at different locations. Contractor or his rep has to ensure power shut down of overhead lines before carrying out trimming. Contractor shall be responsible for any lapses/ mishapning occured due to negelency of safty aspects. |
| 73 | M&L for cleaning of electric substation/installations including cutting/removing of grass, bushes and trimming of branches of trees inside the premises complete all as specified and as directed. |
| 74 | Taking out under ground, HT/LT cables, any sizes, by excavation and earth work in any type of soil, removing bricks or PCC tiles of any size, re-laying in the same trenches for re-routing /after rectification of fault as required complete all as specified and directedNOTE:- (i) Additional bricks, sand shall be measured & paid for separetely.(ii)Retrieved serviceable bricks or PCCcable cover and sandshall be re-laid on the cable & the cost for the same is deemed to be included in the unit rate.(iii) Cost for excavation, R&F, removing shall be included in quoted rate. |
| 75 | M&L for servicing of LT panels by disconnecting all cables connection and removing all unwanted connection /materials and fixing of unsv/burnt lugs by replacing the new copper lugs and tightening all lugs by crimping tools. Proper cleaning of panel by brushes etc including painting by two coats of synthetic enamel paint. All opened door will be refix properly by welding/fixing of hinges, nuts & bolts etc complete all as specified and as directed. |
| 76 | M&L for repairs to main electric panel at sub stations by tightning the all loose connections of the cable ends and replacing the damage/US/burnt aluminium lugs of required sizes, insulating/secure the weak insulated portion of cables ends inside the panel by taping with good quality of insulation tape, clean the dust by air blower complete all as specified and as directed. |
| 77 | M&L for attending complaint ofrepair/replacement of jumper on pole including taking out defective portion and making connection by providing suitable size conductor complete all as specified and as directed. |
| 78 | M&L for attending complaint by disconnecting over head conductor, cutting worn out portion of LT under ground cables of any size and capacity includes taking out cable from under ground loop and rejoin the same to restore electric supply complete all as specified and as directed. |
| 79 | M&L for attending complaint by disconnecting cable from LT switch gear/main switch of any type and capacity including providing suitable size of aluminium lugs complete all as specified and as directed. |
| 80 | Labour onlyfor attending complaint by replacement of worn out insulators of any type and size for 1100 Volts grade complete all as specified and as directed.Note:- Insulator will be measured and paid seperatly under respective items. |