Tender For Repair Maint Of Search Light Tower Lights Perimeter And Security Lights And Connected Items In Tech Area Under Ge Af Tech Area Agra, agra-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair Maint Of Search Light Tower Lights Perimeter And Security Lights And Connected Items In Tech Area Under Ge Af Tech Area Agra. Submission Date for this Tender is 12-06-2023. LED Light Tenders in agra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

37680967
Corrigendum : Tender For Repair Maint Of Search Light Tower Lights Perimeter And Security Lights And Connected Items In Tech Area Under Ge Af Tech Area Agra
Open Tender
Indian
Uttar Pradesh
agra
12-06-2023

Tender Details

Repair Maintenance Of Search Light Tower Lights Perimeter And Security Lights And Connected Items In Tech Area Under Ge Af Tech Area Agra

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-May-2023 Corrigendum1 Other 05-06-2023
2 05-Jun-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 12-06-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 94000.0 /-
Tender Value
INR 47 Lakhs /-

BOQ Items

Name of Work: Repair /Maint of Search lights,Tower lights, perimeter and security lightsand connected items in tech area under GE(AF) Tech AreaAgra
Sl. No. Item Description
1Excavation in trenches in soft/ loose soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay andpipe line,and getting out complete all as specified and directed.
2Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in soil complete all as specified and directed.
3Removing excavated soiln. exc 50 m and depositing where directed at a level n.exc. 1.5 mtr above the starting pointcomplete all as specified and directed.
4M&L for laying of bricks locally available sub class "B" bricks (old size) for cable protection cover, laid flat and dry in trenches over the cable perpendicular to the direction of cablecomplete all as specified and directed.
5Labour only for re-laying of old serviceable bricks retreived from Item No. 1&7for cable protection cover, laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed.
6M&L for local sand coushioning with dry and clean sand over and under the cable for protection of cable , 80 mm thick sand laid before laying the cable 150 mm thick sand after laying the cable complete all as specified and directed. Note : Thickness of sand will be measured after punning for payment purpose.
7Taking out old serviceable/ unserviceable LT UG cables of any size of 10 to 70 sq mm, 2/3.5/4 corefrom trenches, poles/walls and floor includuing taking out old serviceable bricksfrom trenches complete all as specified and directed.
8Laying only serviceableXLPE LTUG cable PVC insulated , beddedarmoured heavy duty electric cable 1100 volts grade with aluminium conductor offollowing sizes laid in trenches or fixed on walls/floor/pole complete all as specified and as directed.
910 sqmm to 95 Sqmm 3.5/4 core
10Supply and LayingXLPE LTUG cable PVC insulated , beddedarmoured heavy duty electric cable 1100 volts grade with aluminum conductor of the following sizes laid in trenches or fixed on wall/floor/poles completeall as specified and as directed:-
11(a)10 Sq mm 4 core
12(b)16 Sq mm 4 core
13(c) 25 Sq mm 4 core
14(d) 35 Sq mm 3.5 core
15(e) 50 Sq mm 3.5 core
16(f) 70 Sq mm 3.5 core
17M&L for jointing kit suitable for LT 1100 volts cable (earthed) for out door straight through joint, heat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable complete all as specified and directed of the following sizes :-
1825 to 50 Sqmm 3.5/4 core
1970 to 120 Sqmm 3.5 core
20M&L for End jointing kit suitable for LT 1100 volts cable (earthed) for out doorheat shrinkable type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable complete all as specified and directed of the following sizes :-
2110 to 50 Sqmm 3.5 core
2270 to 120 Sqmm 3.5 core
23S&F Security light bracket made of GI pipe 40 mm dia, light grade for mounting, bracket bent to shape 1.50 RMincluding suitable clamps made with flat iron 32x6mm -(04 Nos) 02 Sets nut bolt including painted with two coat aluminium paint over a coat of red oxide primer and with and includingall fixing arrengment complete all as specified and directed.
24Taking down carefully unserviceable LED street light, flood light fitting upto 250 watts of any type from pole/wall/High mast dismantling and checking out serviceability of parts/circuit such as drivers, MCPCB etc, repalcement of unserviceable parts with new parts including soldering with existing circuit board, reassembling and refixing in position including connecting, testing complete all as specified and directed. Note : New parts will be measured and paid separately under relevant items of BOQ as "supply only".
25Supply only driver suitable for LED Security light 25/30 Watt complete all as specified and directed.
26Supply onlydriver suitable for LED Security light 45/60/90 Watt complete all as specified and directed.
27Supply only driver suitable for LED Flood light 90/120/150 Watt complete all as specified and directed.
28Supply only driver suitable for LED Flood light 200/250 Watt complete all as specified and directed.
29Supply and fixing inrepairLED landscape light fitting luminaires comprising of epoxy powder coated housing, enclosed with glass cover in frame , IP-65,25 watt LED for gates with and including all fixing arrangements complete all as specified and directed.
30Supply and fixing inrepairLED road way light fitting luminaires comprising of epoxy powder coated housing, enclosed with glass cover in frame IP-66,30 watt LEDcomplete all as specified and directed.
31Supply and fixing in repair of LED road way light fitting luminaires ,comprising ofepoxy powder coatedhousing ,enclosed with glass cover in frame , IP-65, 45 watt LED with 110LM/W complete all as specified and directed.
32Supply and fixing in repair of LED road way light fitting luminaires ,comprising ofepoxy powder coatedhousing ,enclosed with glass cover in frame , IP-66, 60 watt LED with SPD 10 KV , efficiency 110LM/W complete all as specified and directed.
33Supply and fixing in repair LED flood light fitting suitable for fixing on high mast light including all fixing arrangementhigh grade aluminium pressure die cast and toughened glass 110 lumen/watt and high spread using high quality lenses and reflector including over voltage protection up to 300 volts completeof 120 watt completeall as specified and directed.
34Supply and fixing inrepairLED flood light fitting suitable for high mast light with and including all fixing arrangement high grade aluminium pressure die cast and toughend glass 110 lumen/watt and high spread using high quality lenses and reflector including over voltage protection up to 300 volts complete of 150 watt complete all as specified and directed.
35Supply and fixing inrepairLED flood light fitting suitable for high mast light with andincluding all fixing arrangement high grade aluminium pressure die cast and toughend glass 110 lumen/watt and high spread using high quality lenses and reflector including over voltage protection up to 300 volts complete of 250 watt complete all as specified and directed.
36Supply and fixing MCB SP 6 to 32 Amps, 230 volts, 10 KA with enclosure in existing highmast panel complete all as specified and directed.
37S&F Weather Proof thermo plastic (Polysterene) Cable Junction box with 4 aluminium strip bar(25x3 mm) , having protection class IP-65 and of overall size 205mm x 255mm x 112mm having metric knockouts on the wall, having three phase cable connecter, duly fixed with the pole with clamp, GI bolts, nuts, washers and 2 Nos polymide weather proof cable glandsof cable sealing range 10mm to 17mm (Complete with check nut) and including 1 No 30 Amps4 Way cable connector and 1 No. 6 Amps SP MCB complete all as specified and directed.
38M & L Painting to existing LT Panels, angle iron support bracings, clamps etc. with two coats of aluminium paint superior quality of approved make on surfaces exposed to view external surface above PCC benching including preparation of old painted surfaces by scraping etc complete all as specified & directed.
39Preparation of old painted surface of steel tubular poles of 9 mtr long including cross arms, cable protection pipe, bus bar box and painting of complete area with one coat of aluminium paint from 1.5 mtr above ground level to top of pole and making alternate strips/layers (30 cm wide) with white and blue synthetic enamel paint upto the 1.50 meter height from the ground level including writing the pole number in white letters on black background and cleaning/cutting the grass/bushes at a radius of 2 mtr surrounding the pole complete all as specified and directed.
40M&L for Copper bus bar chamber fixed on insulator welded with angle iron of size 50x50x6 mm thick grouting in floor, 450 mm depth grouting with PCC (size 450x450x300 mm)1:3:6 type C-2 using 40mm graded stone aggregate upto ground level and 600 mm high above GL complete all as specified and directed of the following sizes :-
41200 Amps copper bus bar 04 Nos
42100 Amps copper bus bar 04 Nos
43S & F in repair cage for protection/housing LED lights made out of 4mm dia GI wire along with suitable size of angle iron frame fixed on foundation with necessary anchor fastner and nut bolts etc complete the size of cage should be 550x450x550 mmincluding one side with cage opening and locking arrangement and painted with black super enamel paint over a coat of red oxide primer etc complete all as specified and directed.
44Supply and fixing in repair on pole/ wallPVC insulated heavy duty electric cable unarmoured with stranded aluminiumconductor flat/round with including fixing arrangementcomplete all as specified and directed of the following sizes:-
452 core, 1.5 Sqmm
462 core, 2.5 Sqmm
472 core, 4 Sqmm
482 core, 10 Sqmm
49Supply and fixing MCCB of the following sizes on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and as directed -
50(a) MCCB 4 pole , 100 amp rating of 16 KA
51(b) MCCB 4 pole , 63 amp rating of 16 KA
52M&L for repair ofStreet light panels and timer switch with replacement of unserviceable and burnt parts including all wiring and setting of timer switch with sun set and sunrise including all necessary accesories required for smooth functioning of panel and timer switch complete all as specified and directed
53M&L for repair ofSwivel/search LED lights including motor repair/winding, circuit repair andrepair of all un-serviceable parts of panel board of swivel light including all necessary accesories required for smooth functioning of Swivel/Search lights. Note : (i)The working height of watch tower is min 15 meter (ii) The contractor shall carry his own arrangementfor carrying out the repair work (iii). Contractor quoted rate shall be deemed to be included above aspect. No extra charge shall be paid to contractor on this account.
54Carryout day to day rectification of external electrifical complaints such as repair, reconnection and lightening of burnt/loose cable laid in MCCB/MCB of existing LT indoor/outdoor panels and bus bar with suitable size lug/thimbles, attending external electrical no supply complaints, jointing of traced out burnt cable with suitable size of jointing kit complete all as specified and directed. "Note : (a) Replacement of major items shall be measured and paid under relevant items of this schedule. (b) Repairing upto 03 points at different electrical system without any other material will be considered as one job.
55Material & labour for earthing with galvanised steel earth plate electrode 60cm x 60cm x 6.00mm thick burried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate shall be at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron strip of 25 x 4 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by40 mm dia GI pipe medium grade connected to main switch board or main control board or equipment and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, 40mm thick RCC pit cover reinforcedwith 8mm dia TMT bar at 75 mm c/c both ways and lifting arrangement by providing handles (02 Nos) of 12mm dia MS round bar and PCC chamber pit with PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) including excavation and earth work in soft/loose soil, returning, filling in with excavated soil and disposal of surplus soil to a distance not exceeding 50m and shown in electrical Plate No 3 of SSR 2009 (Part-I) complete all as specified and directed.
56Supply, erecting and fixing in repair in true vertical position, steel tubular swaged pole (410 SP-31) double swan neck type, 09 meter long, complete with cast iron base plate, pole cap, mild steelbolts, nutsand screw including one coats of black bituminous paint externally (upto planting depth) and remaining exterior portion of pole shall be painted with two coats of aluminium paint over a coat of red oxide primer including preparetion of surface including painting blue(sky blue) strips of 30 cm width with synthetic enamel paint in alternate layers up to 1.5 mtr above the plinth block, writing letter or figures (Block Roman, Italic as Indian) with thick synthetic enamel paint of approved shade not exceeding 5 cm height including numbering of pole, painting of coping with two coat of cement based paint etc complete all as specified and directed. Note : Excavation, Earth work and PCC etc shall be measured and paid separately.
57Excavating in trenches, n exc 1.5 m wide and exc 1.5 m in depth but n exc 3.0 m; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan for errection of pole and getting out complete all as specified and directed.
58M&L for cement concrete (1:3:6) type C2 using 40 mm gradded stone aggregatein foundations , filling and mass concrete etccomplete all as specified and directed.
59Demolition of PCC/Black bituminous road of any description andin any position not otherwise specially provided , etc complete all as specified and directed.
60M&L for Cement Concrete (1:2:4) type B1 using 20 mm gradded stone aggregate for copingof poles, panel board and filling of road cutting etccomplete all as specified and as directed.
61M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and directed
62M & L for painting to existing light pillar withtwo coats of synthetic enamel paint of superior quality of approved make on surfaces exposed to view external surface above PCC benching including preparation of old painted surfaces by scraping etc complete all as specified & directed.
63M&L for GI tube light gradegalvanised with all fittings for earthing lead protection of under ground /on wall/pole size 20 mm dia completeall as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail